Template:
Building Plans
Street #
5622
Location
11th St
Contractor
Bourguenon, Jerry
Description
Southern Skies Apartment House
Building Plans - Permit #
22747
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C <br />5pc <br />LIGHTING PLAN - SECOND FLOOR <br />1 /41'= 1'-011 <br />LIGHTING PLAN - GROUND FLOOR <br />1 /4" = 1'-011 <br />:L-5 <br />GENERAL NOTES <br />1. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION AND <br />REQUIREMENTS. <br />2. REFER TO ARCHITECTURAL AND MECHANICAL DRAWINGS FOR <br />ADDITIONAL INFORMATION AND REQUIREMENTS. <br />3. REFER TO STRUCTURED CABLING SPECIFICATIONS UNDER SEPARATE <br />COVER. <br />4. REFER TO POWER ONE -LINE FOR ADDITIONAL INFORMATION AND <br />REQUIREMENTS. <br />5. COORDINATE LOCATION AND MOUNTING HEIGHT OF ALL DEVICES WITH <br />OWNER PRIOR TO ROUGH -IN. <br />6. MAXIMUM 3 QUARTER TURN (TOTAL 270°) CONDUIT BENDS BETWEEN <br />JUNCTION/PULL BOXES. <br />7. COORDINATE EXACT LOCATION OF ALL EXTERIOR WALL PENETRATIONS <br />WITH ARCHITECT. SEAL TO MAINTAIN WATER TIGHTNESS AND FIRE <br />RATING. <br />8. COORDINATE ORIENTATION OF DEVICE WITH ARCHITECT. <br />9. COORDINATE LOCATION AND MOUNTING HEIGHT OF BOXES FOR CABLE <br />TV OUTLETS WITH OWNER. <br />10. COORDINATE LOCATION AND MOUNTING HEIGHT OF RECEPTACLES FOR <br />WALL MOUNTED TVs WITH OWNER. <br />11. COORDINATE EXACT LOCATION AND REQUIREMENTS FOR CONNECTION <br />TO MECHANICAL EQUIPMENT WITH EQUIPMENT SUPPLIER/INSTALLER <br />AND APPROVED SHOP DRAWINGS PRIOR TO ROUGH -IN AND MAKE <br />APPROPRIATE ADJUSTMENTS AS REQUIRED. INSTALL PER <br />MANUFACTURER'S RECOMMENDATIONS. PROVIDE ALL NECESSARY <br />BOXES, WIRING, ETC FOR COMPLETE AND OPERATIONAL SYSTEM. <br />12. EC TO PROVIDE BOXES AND CONDUITS AS REQUIRED FOR MECHANICAL <br />EQUIPMENT CONTROLS. COORDINATE REQUIREMENTS WITH <br />MECHANICAL AND CONTROLS CONTRACTOR. <br />13. PROVIDE PLASTIC INSULATED BUSHINGS AND PULL STRINGS FOR ALL <br />LOW VOLTAGE CONDUITS. <br />14. IT AND POWER CONDUITS SHOULD CROSS AT 90° AND MAINTAIN <br />MINIMUM 12" SEPARATION BETWEEN CONDUITS AT ALL TIMES. <br />15. PATCH AND PAINT WALLS AS REQUIRED WHERE DEVICES, BOXES, ETC <br />ARE REMOVED OR REWORKED. <br />16. EXTEND CONDUITS AND CONDUCTORS AS REQUIRED. <br />17. REFER TO ARCHITECTURAL PLANS FOR FLOOR TRENCHING AND <br />PATCHING REQUIREMENTS. <br />18. NO FOREIGN SYSTEMS SUCH AS PIPING AND DUCTS SHALL BE ROUTED <br />ABOVE ELECTRICAL EQUIPMENT. <br />KEYNOTES <br /># <br />KEYNOTE TEXT <br />1 <br />2#12 + #12G - 3/4"C <br />2 <br />FIXTURE A: JUNO - 6" RECESSED DOWN LIGHT CATALOG NUMBER <br />6RLS-07L0-2700-90CRI-120-FRPC-WH OR APPROVED EQUAL. <br />3 <br />FIXTURE C: LITHONIA WALL PACK CATALOG NUMBER TWH LED ALO 40K, UPC# <br />191848355251 OR APPROVED EQUAL. COORDINATE WITH OWNER/ARCHITECT <br />FOR EXACT LOCATION PRIOR ROUGH -IN AND INSTALLATION. FIXTURE SHALL <br />BE CONTROLLED BY PHOTOCELL. <br />4 <br />FIXTURE B: JUNO - 6" RECESSED DOWN LIGHT CATALOG NUMBER <br />6RLS-07L0-2700-90CRI-120-FRPC-WH OR APPROVED EQUAL (WET LISTED) OR <br />APPROVED EQUAL. FIXTURE SHALL BE CONTROLLED VIA PHOTOCELL. <br />COORDINATE WITH ARCHITECT PRIOR ROUGH -IN AND INSTALLATION. <br />5 <br />PROVIDE PHOTOCELL WITH TIME CLOCK. PHOTOCELL SHALL BE PLACED AT <br />HIGHEST POINT OF ROOF. COORDINATE EXACT LOCATION WITH ARCHITECT. <br />LUMINAIRE GENERAL NOTES: <br />1. ALL INTERIOR LUMINAIRES TO HAVE A COLOR TEMPERATURE OF 3500K UNLESS OTHERWISE <br />DIRECTED BY ARCHITECT. <br />2. COORDINATE LIGHTING CONTROL AND ANY DIMMING CAPABILITY WITH LUMINAIRE <br />MANUFACTURER AND PROVIDE APPROPRIATE RECOMMENED MANUFACTURER APPROVED <br />DEVICE. <br />3. COORDINATE ALL LUMINAIRE COLORS, FINISHES, AND MOUNTING OPTIONS WITH ARCHITECT <br />PRIOR TO ORDERING. <br />4. COORDINATE MOUNTING HEIGHTS AND LOCATIONS WITH ARCHITECT PRIOR TO ROUGH -IN AND <br />INSTALLATION. <br />5. ALL EMERGENY AND EXIT LIGHTING SHALL REMAIN ON AT ALL TIMES. <br />6. ALL LED LUMINAIRES SHALL BE CAPABLE OF DIMMING. <br />7. EQUIVALENT LUMINAIRES ARE ACCEPTABLE FOR REVIEW AND APPROVAL FROM TAMPA BAY <br />LIGHTING INC, WESTERN FLORIDA LIGHTING, AND ENVISION LIGHTING SYSTEMS. <br />o <br />� <br />U <br />cD <br />E <br />,- <br />O <br />V <br />� <br />� <br />CO <br />a, <br />N <br />O <br />s <br />8 <br />N <br />ca <br />V <br />co <br />E <br />O <br />M <br />,- <br />W <br />o <br />W-14 <br />No 85232 <br />ST7TE,00 <br />i • +�/ <br />/ O \\s/AMA; f11\\�� <br />U) <br />Z� <br />W <br />Z <br />VJ <br />~ <br />=W <br />U� <br />w <br />O <br />2Q <br />�Q <br />< <br />zz <br />IX oZ <br />0� <br />w <br />o <br />Ili <br />w <br />W i <br />OW <br />W <br />(6 <br />O <br />W� <br />J_ <br />W <br />=r <br />LL <br />0 <br />OF�/'� <br />UZ <br />VJ <br />Q <br />N <br />co W <br />N <br />Renna Enterprises, Inc. <br />P.E. N 85232 Irving Ho, P.E. <br />AUTH. M 00008631 Consulting Engineers <br />3231 Drone Field Road Ph. (863) 646 1258 <br />Lakeland, FI 33811 Fax. (863) 646 8881 <br />E 4 <br />