MECHANICAL LEGEND <br />SYMBOL <br />DESCRIPTION <br />NEW DUCTWORK, PIPING, OR EQUIPMENT <br />FLEXIBLE DUCT <br />RETURN, TRANSFER OR EXHAUST AIR DEVICE <br />OT <br />WALL MOUNTED THERMOSTAT <br />MSAH <br />MINI SPLIT AIR HANDLING UNIT <br />MSCU <br />MINI SPLIT CONDENSING UNIT <br />CFM <br />CUBIC FEET PER MINUTE <br />FPM <br />FEET PER MINUTE <br />N <br />NEW <br />CONTRACTOR NOTES <br />IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE <br />ARCHITECT, LANDLORD OR TENANT OF ANY DISCREPANCIES <br />ENCOUNTERED ON THE PLANS OR IN SITE CONDITIONS PRIOR TO <br />SUBMISSION OF BID. <br />BIDDERS ARE FAMILIARIZE THEMSELVES WITH CONDITIONS AND SATISFY <br />THEMSELVES AS TO THE NATURE AND SCOPE OF THE WORK. THE BASE <br />BID SHALL REFLECT MODIFICATIONS TO SYSTEMS AND DEVICES AS <br />REQUIRED BY STATE, LOCAL AND FEDERAL CODES WHETHER INDICATED <br />OR NOT ON CONTRACT DOCUMENTS. THE SUBMISSIONS OF A BID WILL <br />BE EVIDENCE THAT SUCH AN EXAMINATION AND COMPLIANCE WITH <br />GOVERNING CODES/REQUIREMENTS HAS BEEN MADE. LATER CLAIMS FOR <br />LABOR, EQUIPMENT, OR MATERIALS REQUIRED, OR FOR DIFFICULTIES <br />ENCOUNTERED WHICH COULD HAVE BEEN FORSEEN HAD AN EXAMINATION <br />AND CODE/REQUIREMENTS REVIEW BEEN MADE, WILL NOT BE ALLOWED. <br />O NEW MINI SPLIT AIR HANDLING UNITS ARE TO BE WALL MOUNTED HIGH AS <br />POSSIBLE. SEE "SPLIT SYSTEM A/C SCHEDULE" ON SHEET M2 FOR <br />FURTHER INFORMATION. <br />O LOCATE CONDENSING UNIT OUTSIDE ON CONDENSING PAD. COORDINATE LOCATION <br />WITH ARCHITECT/CLIENT. PROVIDE 4" CONCRETE PAD. <br />03 PROVIDE NEW/SCHEDULED TOILET EXHAUST FAN, ROUTE EXHAUST <br />DUCTWORK TO WALL EXHAUST CAP. WALL CAPS FOR GROUND FLOOR <br />UNITS SHALL BE LOCATED ABOVE GROUND. <br />04 PROVIDE 4" METALLIC DRYER VENT WITH WALL CAP. DRYER WALL CAP <br />FOR GROUND FLOOR UNITS SHALL BE LOCATED ABOVE GROUND. <br />05 ROUTE REFRIGERANT LINES FROM MSAH UNITS IN GROUND FLOOR THRU <br />EXTERIOR WALL TO RESPECTIVE CONDENSING UNITS. <br />O6 ROUTE REFRIGERANT LINE FROM MSAH IN SECOND FLOOR THRU <br />EXTERIOR WALL DOWN TO CONDENSING UNIT OUTSIDE. <br />07 ROUTE NEW 5/6" CONDENSATE DRAIN LINE FROM MINI SPLIT AIR <br />HANDLIND UNITS THRU EXTERIOR WALL TO DRYWELL. <br />O COORDINATE LOCATION OF WIRELESS REMOTE TEMPERATURE CONTROLLER <br />WITH ARCHITECT/OWNER. <br />1 7 MSAH-1 <br />MOUNT HIGH A <br />POSSIBL <br />m PROPOSED SECOND FLOOR PLAN - MECHANICAL <br />MSCU-3 MSCU-1 MSCU-2 MSCU-4 <br />O O 00 O <br />I i I ODRYWELL <br />PROPOSED GROUND FLOOR PLAN - MECHANICAL <br />SCALE: 1 /4"=1'-O" 19167 <br />,P O <br />4"0 METALLIC <br />DRYER DUCT <br />ALLO <br />R&wa Enterprises, in <br />RE # 56067 Ronald R. Renna, P.E. <br />AUTH. # 00008631 Consulting Engineers <br />3231 Drane Field Road Ph. (863) 646 1258 <br />Lakeland, FI 33811 Fax.(863) 646 8881 <br />0 U W <br />Z <br />-j Z <br />m <br />=WWO <br />U Q <br />2 Q Z Q <br />0 z LU E2 <br />o� W wo <br />z� F-U) <br />ins __ <br />WLL <br />o°O N= <br />U Z Lo Lf- <br />W <br />01 NOV 2019 <br />m 1 <br />