My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
5622 11th St
Zephyrhills
>
Building Department
>
Building Plans
>
5622 11th St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2025 8:37:55 AM
Creation date
2/18/2025 3:21:52 PM
Metadata
Fields
Template:
Building Plans
Street #
5622
Location
11th St
Contractor
Bourguenon, Jerry
Description
Southern Skies Apartment House
Building Plans - Permit #
22747
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MINI -SPLIT SYSTEM <br />SCHEDULE (MITSUBISHI MULTIZONE <br />HEAT PUMP) <br />AIR HANDLER DATA <br />TAG <br />- <br />MSAH-1A <br />MSAH-2A <br />MSAH-3A <br />MSAH-4A <br />MSAH-1B <br />MSAH-26 <br />MSAH-313 <br />MSAH-413 <br />NOMINAL TONNAGE <br />TONS <br />1.0 <br />1.0 <br />1.0 <br />1.0 <br />0.5 <br />0.5 <br />0.5 <br />0.5 <br />TOTAL CAPACITY <br />BTUH <br />12,000 <br />12,000 <br />12,000 <br />12,000 <br />6,000 <br />6,000 <br />6,000 <br />6,000 <br />SENSIBLE CAPACITY <br />BTUH <br />18,500 <br />8,500 <br />8,500 <br />8,500 <br />4,200 <br />4,200 <br />4,200 <br />4,200 <br />FAN SPEED <br />- <br />VARIABLE <br />VARIABLE <br />VARIABLE <br />VARIABLE <br />VARIABLE <br />VARIABLE <br />VARIABLE <br />VARIABLE <br />SUPPLY AIR <br />CFM <br />135-400 <br />135-400 <br />135-400 <br />135-400 <br />135-380 <br />135-380 <br />135-380 <br />135-380 <br />THERMOSTAT SETTING <br />'F <br />74 <br />74 <br />74 <br />74 <br />74 <br />74 <br />74 <br />74 <br />IFM FULL LOAD AMPS <br />- <br />0.67 <br />0.67 <br />0.67 <br />0.67 <br />0.67 <br />0.67 <br />0.67 <br />0.67 <br />VOLTAGE <br />V/0 <br />240/1 <br />240/1 <br />240/1 <br />240/1 <br />240/1 <br />240/1 <br />240/1 <br />240/1 <br />ELECTRICAL (OUTPUT) <br />WATTS <br />1 30 <br />30 <br />30 <br />30 <br />30 <br />30 <br />30 <br />30 <br />FILTER TYPE <br />- <br />CLEANABLE <br />CLEANABLE <br />CLEANABLE <br />CLEANABLE <br />CLEANABLE <br />CLEANABLE <br />CLEANABLE <br />CLEANABLE <br />UNIT WEIGHT <br />LBS <br />29 <br />29 <br />29 <br />29 <br />29 <br />29 <br />29 <br />29 <br />HEAT <br />- <br />HEAT PUMP <br />HEAT PUMP <br />HEAT PUMP <br />HEAT PUMP <br />HEAT PUMP <br />HEAT PUMP <br />HEAT PUMP <br />HEAT PUMP <br />DESIGN BASED ON <br />- <br />MITSUBISHI <br />MITSUBISHI <br />MITSUBISHI <br />MITSUBISHI <br />MITSUBISHI <br />MITSUBISHI <br />MITSUBISHI <br />MITSUBISHI <br />MODEL NO. <br />- <br />MSZ-FH12NA <br />MSZ-FH12NA <br />MSZ-FH12NA <br />MSZ-FH12NA <br />MSZ-FH06NA <br />MSZ-FH06NA <br />MSZ-FH06NA <br />MSZ-FH06NA <br />CONDENSING UNIT DATA <br />TAG <br />- <br />MSCU-1 A <br />MSCU-2A <br />MSCU-3A <br />MSCU-4A <br />MSCU-1 B <br />MSCU-28 <br />MSCU-38 <br />MSCU-4B <br />OUTDOOR TEMP. <br />OF <br />95 <br />95 <br />95 <br />95 <br />95 <br />95 <br />95 <br />95 <br />VOLTAGE <br />V/0 <br />240/1 <br />240/1 <br />240/1 <br />240/1 <br />240/1 <br />240/1 <br />240/1 <br />240/1 <br />ELECTRICAL (MCA/MOCP) <br />AMPS <br />17.2/20 <br />17.2/20 <br />17.2/20 <br />17.2/20 <br />17.2/20 <br />17.2/20 <br />17.2/20 <br />17.2/20 <br />UNIT WEIGHT <br />LBS <br />126 <br />126 <br />126 <br />126 <br />126 <br />126 <br />126 <br />126 <br />SEER ® ARI CONDITIONS <br />- <br />20.0 <br />20.0 <br />20.0 <br />20.0 <br />20.0 <br />20.0 <br />20.0 <br />20.0 <br />REFRIGERANT TYPE <br />- <br />R410A <br />R410A <br />R410A <br />R410A <br />R410A <br />R410A <br />R410A <br />R410A <br />DESIGN BASED ON <br />- <br />MITSUBISHI <br />MITSUBISHI <br />MITSUBISHI <br />MITSUBISHI <br />MITSUBISHI <br />MITSUBISHI <br />MITSUBISHI <br />MITSUBISHI <br />MODEL NO. <br />- <br />MXZ-2C2ONA2 <br />MXZ-2C20NA2 <br />MXZ-2C20NA2 <br />MXZ-2C20NA2 <br />MXZ-2C20NA2 <br />MXZ-2C20NA2 <br />MXZ-2C20NA2 <br />MXZ-2C20NA2 <br />NOTES: <br />Q1 PROVIDE/INSTALL WITH CODE REQUIRED CONDENSATE OVER FLOW SAFETY DEVICE/SENSOR (MICROBLUE DIAMOND PUMP), INSULATE PER CODE. <br />PROVIDE DUAL FAN COIL UNIT UNESET TO SINGLE CONDENSER, <br />O2 DISCONNECT PROVIDED/WIRED BY ELECTRICAL. <br />Q PROVIDE OUTDOOR 4" CONDENSING UNIT PAD, PER CODE. COORDINATE ARCHITECTURAL PLANS FOR EXACT LOCATION. <br />® PROVIDE/INSTALL WITH FACTORY NON -FUSED DISCONNECT SWITCH. <br />5O PROVIDE/INSTALL FACTORY WIRING HARNESS BETWEEN UNITS, REFRIGERANT PIPING AND FACTORY OPTIONS AS REQUIRED FOR A COMPLETE INSTALLATION. <br />© PROVIDE VARIABLE SPEED INVERTER DRAWN COMPRESSOR, HIGH PRESSURE SWITCH, AIR DISCHARGE GUIDE, AND CONTROL CABLE. <br />7O PROVIDE FAN COIL UNIT WITH 3D I -SEE SENSOR, WIRELESS REMOTE CONTROLLER, AND DOUBLE VANE SUPPLY AIR OUTLET. <br />® PROVIDE/INSTALL WITH FACTORY ACCESSORIES TO ACHIEVE LOW AMBIENT COOLING AS/IF REQUIRED. <br />MODEL NUMBERS SHALL NOT BE CONSIDERED COMPLETE AND MATERIAL SHALL NOT BE ORDERED BY MANUFACTURER AND MODEL NUMBERS ONLY. REVIEW THE COMPLETE DESCRIPTION, NOTES AND <br />BUILDING CONDITIONS TO DETERMINE THE EXACT MATERIAL AND ACCESSORIES TO BE ORDERED. <br />SPLIT SYSTEM HEAT PUMP CONTROL SEQUENCE OF OPERATION <br />THE MSAH/MSCU SHALL BE STARTED AND STOPPED FROM A ROOM <br />THERMOSTAT. ON A CALL FOR COOLING, THE THERMOSTAT SHALL ENERGIZE <br />THE COMPRESSOR TO MAINTAIN SET POINT. ON A CALL FOR HEATING, THE <br />THERMOSTAT SHALL ACTIVATE THE HEAT PUMP/CONDENSING UNIT <br />CHANGE -OVER VALVE TO MAINTAIN SET POINT. THE INDOOR FAN SHALL <br />CYCLE WITH THE CONDENSING UNIT AS REQUIRED. <br />EXHAUST FAN SCHEDULE <br />TAG <br />- <br />EF-1 <br />EF-2 <br />EF-3 <br />EF-4 <br />SERVICE <br />- <br />EXHAUST <br />EXHAUST <br />EXHAUST <br />EXHAUST <br />AIR QUANTITY <br />CFM <br />50 <br />50 <br />50 <br />50 <br />EXT. STATIC PRESS. <br />IN. H2O <br />0.35 <br />0.35 <br />0.35 <br />0.35 <br />FAN TYPE <br />- <br />CEILING <br />CEILING <br />CEILING <br />CEILING <br />DRIVE <br />- <br />DIRECT <br />DIRECT <br />DIRECT <br />DIRECT <br />DUCT SIZE <br />- <br />4"0 <br />4"0 <br />4"0 <br />4"0 <br />SONES <br />- <br />1.0 <br />1.0 <br />1.0 <br />1.0 <br />MOTOR (INPUT) <br />WATTS <br />80 <br />80 <br />80 <br />80 <br />FAN SPEED <br />RPM <br />763 <br />763 <br />763 <br />763 <br />UNIT WEIGHT <br />LBS <br />12 <br />12 <br />12 <br />12 <br />POWER <br />V/0 <br />115/1 <br />115/1 <br />115/1 <br />115/1 <br />CONTROL <br />_ <br />INTERLOCK W <br />R.R. LIGHTING <br />INTERLOCK W <br />R.R. LIGHTING <br />INTERLOCK W <br />R.R. LIGHTING <br />INTERLOCK 1 <br />R.R. LIGHTIN <br />AREA SERVED <br />- <br />TOILET ROOM <br />TOILET ROOM <br />TOILET ROOM <br />TOILET ROOM <br />DESIGN BASED ON <br />- <br />GREENHECK <br />GREENHECK <br />GREENHECK <br />GREENHECK <br />MODEL <br />- <br />SP-B110 <br />SP-B110 <br />SP-13110 <br />SP-B110 <br />NOTES <br /># <br />1 2 3 <br />1 2 3 <br />1 2 3 <br />1 2 3 <br />1Q PROVIDE/INSTALL WITH FACTORY PLUG-IN DISCONNECT, BACKDRAFT DAMPER, INTAKE GRILLE <br />AND HANGING VIBRATION ISOLATOR KIT. <br />2Q SUPPLY FACTORY WALL EXHAUST CAP(S) AS REQUIRED, SEE MECHANICAL ROOF PLAN <br />FOR SIZES AND QUANTITIES. <br />Q PROVIDE/INSTALL WITH FACTORY FAN SPEED CONTROLLER LOCATED IN/AT FAN HOUSING. <br />• IN GENERAL, PLANS AND DIAGRAMS ARE SCHEMATIC ONLY AND SHOULD NOT BE <br />SCALED. <br />• INTENT OF THESE NOTES AND MECHANICAL NOTES ON DRAWINGS IS TO CLARIFY THE <br />SCOPE OF WORK AND ALERT CONTRACTOR OF EXISTING CONDITIONS. CONTRACTOR TO <br />VISIT SITE AND VERIFY ALL CLEARANCES BEFORE FABRICATION OF DUCTWORK AND <br />PROVIDE ADDITIONAL OFFSET AND/OR CHANGES IN DUCT SIZES TO MEET FIELD <br />CONDITIONS AND COORDINATE WITH ELECTRICAL, PLUMBING AND FIRE PROTECTION <br />SUBCONTRACTOR BEFORE ANY CONSTRUCTION WORK. <br />• ALL NEW EQUIPMENT SHALL BE U.L. LISTED AND A.R.I. CERTIFIED. ALL MECHANICAL <br />EQUIPMENT REQUIRING ELECTRICAL POWER SHALL BE INSTALLED WITH DISCONNECT <br />SWITCHES AT EACH PIECE OF EQUIPMENT. COORDINATE SWITCH REQUIREMENTS WITH <br />THE ELECTRICAL CONTRACTOR. IT IS THIS CONTRACTOR'S RESPONSIBILITY TO <br />COORDINATE ALL ELECTRICAL REQUIREMENTS. <br />• THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL TRADES INSTALLATION <br />SCHEDULES. FIXED WORK SUCH AS DUCTWORK AND PLUMBING SHALL BE INSTALLED <br />PRIOR TO ANY TRADE WORK THAT CAN BE EASILY RELOCATED OR OFFSET SUCH AS <br />ELECTRICAL CONDUITS, SMALL WATER LINES ETC. <br />• CONTRACTOR SHALL PROVIDE ALL SUPPLEMENTARY STEEL REQUIRED TO SUSPEND <br />MECHANICAL EQUIPMENT AND MATERIALS. <br />• ALL MECHANICAL WORK SHALL MEET ALL THE REQUIREMENTS OF BUT NOT LIMITED TO <br />THE "2017 FLORIDA MECHANICAL BUILDING CODE" (SIXTH EDITION). <br />• REGARDLESS OF HVAC SCHEDULES, THE MECHANICAL CONTRACTOR TO VERIFY <br />VOLTAGE WITH ELECTRICAL BEFORE ORDERING EQUIPMENT. <br />• ALL MECHANICAL EQUIPMENT CONTROL WIRING TO BE ROUTED IN CONDUIT. <br />• IT SHALL BE THE RESPONSIBILITY OF THIS CONTRACTOR TO INSTALL THE HEATING, <br />VENTILATION AND AIR CONDITIONING SYSTEM SO AS TO INSURE QUIET OPERATION. NO <br />VIBRATION OR SOUND SHALL BE TRANSMITTED TO THE BUILDING, STRUCTURE OR OCCUPIED <br />AREAS. THE DECISION OF THE ENGINEER AS TO THE QUIETNESS OF THE SYSTEM AND <br />EQUIPMENT SHALL BE FINAL. IT SHALL BE THIS CONTRACTOR'S RESPONSIBILITY TO <br />CORRECT OR REPLACE ANY NOISY SYSTEM OR EQUIPMENT AS REQUIRED. <br />• ALL DRYER EXHAUST DUCTS SHALL BE METALLIC. <br />BACKDRAFT DAMPER <br />FLEX CONNECTION <br />CEILING <br />EXHAUST <br />FAN <br />SUPPORT RODS AND <br />SPRING ISOLATORS. <br />SUPPORT FROM <br />STRUCTURE PER CODE. <br />(TYPICAL) <br />GALVANIZED SHEETMETAL--" <br />EXHAUST DUCT. `CEILING <br />SEE MECHANICAL FLOOR <br />PLAN FOR SIZE. FACTORY <br />INTAKE GRILLE <br />CEILING EXHAUST FAN DETAIL <br />NO SCALE <br />CONDENSATE <br />DRAIN PIPE - <br />COVER SET IN BELL <br />SEAL CONNECTION <br />WITH CAULKING <br />FILL ENTIRE WELL WITH <br />1" GRADED WASHED GRAVEL <br />DRYWELL DETAIL <br />NOT TO SCALE <br />FINISH GRADE <br />24" LONG x 24"0 <br />CONCRETE OR <br />PVC PIPE <br />vt <br />0 <br />U <br />00 <br />N <br />Kis <br />00 <br />O <br />M� <br />V <br />� <br />�.� <br />0 <br />s <br />rn <br />c>s <br />V <br />00 <br />O <br />rn <br />0) <br />� <br />W <br />o� <br />ddh f <br />(D <br />W <br />Z <br />o 1- <br />CA <br />J <br />m Z <br />=WWO <br />U Q <br />W� <br />Q <br />z <br />pz <br />W <br />ER <br />� � <br />W <br />L <br />p W <br />w ILL <br />w J_ <br />W p <br />LL <br />° <br />0 <br />} <br />N a <br />O <br />U Z <br />Lo N <br />���►rill���r�� III illy <br />i <br />BT 19 16 <br />6 67 = 01 NOV 2019 <br />r <br />r <br />t <br />-, M2 <br />k' tll�i 1\\`\l4yi <br />Renna Enterprises MC. <br />P.E. # 56067 Ronald R. Renna, P.E. <br />AUTH. # 00008631 Consulting Engineers <br />3231 Drone Field Road Ph. (863) 646 1258 <br />Lakeland, FI 33811 Fax. (863) 646 8881 <br />