Laserfiche WebLink
r <br />. 'f" " - <br />+ + + + + + + + + + «_ « + + + , <br />., l....=1 2. 7 2. 9 3. 1, .s 3 6 1. 4 1. 2 1 0 2. 8 2. 6 2. ?.. 9 L. 5 .2 <br />-------=."( "- 2 T-�' <br />4.6 <br />",.0 3 3.4 9. 3.8 2.6 5.1 <br />4.7 <br />4.7 4.0 <br />3. 2.7 2.2 .7 <br />v •; <br />:..2 2.9 3." <br />5.0 6.2 6.6 <br />.2 5.3 10.6 13.1 11.9 7.1 I.6 <br />6.4 <br />6.6 5.9 <br />4.5 3. 3.2 2.4 <br />3. i 4.2 4.5 <br />�. F,. % 7.2 <br />8.3 11 .3 26�XY 3�1.7 ].5.5.4 <br />8.1 <br />6.Fi 5.7 <br />5.1 5.0 .510M4 <br />(e) <br />(e) <br />4.0 5. 0 5.2 6. 0 7 .. ? , : <br />9 8 35.(0 <br />® 17.3 <br />a <br />+ t + + + <br />9.0 <br />*13.62c(e� 28.6 <br />26.7 20.7 4 <br />.., <br />97.9 4a <br />II <br />m+ <br />CALCULATION SUMMARY AT 36" AFG <br />LABEL <br />CALCTYPE <br />UNIT <br />AVG <br />MAX <br />MIN <br />AVG/MIN <br />MAX/MIN <br />NEW DRIVE -UP ATM (LANE 4) - 5FT COMPLIANCE <br />ILLUMINANCE <br />FC <br />25.33 <br />30.2 <br />21.0 <br />1.21 <br />1.44 <br />SITE - 50FT COMPLIANCE <br />ILLUMINANCE <br />FC <br />9.61 <br />36.7 <br />23 <br />4.18 <br />15.96 <br />KEYED NOTES: <br />OATM FIVE FOOT COMPLIANCE AREA: A MINIMUM OF <br />TEN (10) FOOT CANDLE POWER AT THE FACE OF <br />THE ATM EXTENDING OUTWARD FIVE (5) FEET IN <br />ALL UNOBSTRUCTED DIRECTIONS. <br />O ATM FIFTY FOOT COMPLIANCE AREA: A MINIMUM OF <br />TWO (2) FOOT CANDLE POWER EXTENDING <br />OUTWARD IN ALL UNOBSTRUCTED DIRECTIONS <br />FIFTY (50) FEET FROM THE FACE OF THE ATM. <br />1. REGULATED STATES: THE FOLLOWING STATES REGULATE THE MINIMUM <br />LIGHT LEVELS IN THE VICINITY OF AN ATM, AFTER HOUR DEPOSITORY, <br />AND 24-HOUR VESTIBULE: AI.-Fa,t l-,MA, CALIFORNIA, CONNECTICUT, <br />DISTRICT OF COLUMBIA, FLORIDA, GEORGIA, ILLINOIS, KANSAS, <br />KENTUCKY, LOUISIANA, MARYLAND, MASSACHUSETTS, MISSOURI, <br />MONTANA, NEVADA, NEW HAMPSHIRE, NEW JERSEY, NEW YORK, OREGON, <br />RHODE ISLAND, TEXAS, WASHINGTON. <br />2. LIGHTING CONTROLS: ALL NEW LIGHT FIXTURES SHALL BE INTEGRATED <br />INTO EXISTING LIGHTING CONTROL SYSTEM FOR SIMULTANEOUS <br />OPERATION. EXTERIOR LIGHTING SHALL BE IN SERVICE FROM <br />DUSK -TO -DAWN. RECONFIGURE EXISTING LIGHTING CONTROLS AS <br />REQUIRED. <br />3. ILLUMINATION REQUIREMENTS: ELECTRICAL CONTRACTOR SHALL VERIFY <br />EXISTING AND PROPOSED LIGHTING IN THE VICINITY OF AUTOMATIC <br />TELLER MACHINES, AFTER -HOUR DEPOSITORIES AND 24-HOUR <br />VESTIBULES COMPLY WITH BANK STANDARDS AND APPLICABLE FEDERAL, <br />STATE, AND LOCAL CODES, RULES & REGULATIONS, ORDINANCES, AND <br />STATUTES RELATED TO MINIMUM LIGHTING LEVELS FOR SAFETY. NOTIFY <br />ENGINEER OF ANY DEFICIENCIES FOR CORRECTIVE ACTIONS. FOR <br />REGULATED STATES, MINIMUM LIGHTING LEVELS SHALL MEET THE <br />CRITERIA LISTED HEREIN: <br />A. DRIVE -UP ATM OR NIGHT DEPOSITORY: A MINIMUM OF TEN (10) <br />FOOT-CANDLE POWER AT THE FACE OF THE ATM OR AFTER -HOUR <br />DEPOSITORY EXTENDING OUTWARD FIVE (5) FEET IN ALL <br />UNOBSTRUCTED DIRECTIONS. A MINIMUM OF TWO (2) FOOT-CANDLE <br />POWER EXTENDING OUTWARDS IN ALL UNOBSTRUCTED <br />DIRECTIONS FIFTY (50) FEET FROM THE FACE OF THE ATM AND <br />AFTER -HOUR DEPOSITORY. <br />B. WALK-UP ATM OR NIGHT DEPOSITORY: A MINIMUM OF TEN (10) <br />FOOT-CANDLE POWER AT THE FACE OF THE ATM OR AFTER -HOUR <br />DEPOSITORY EXTENDING OUTWARD FIVE (5) FEET IN ALL <br />UNOBSTRUCTED DIRECTIONS. A MINIMUM OF TWO (2) FOOT-CANDLE <br />POWER WITHIN SIXTY (60) FEET OF THE ATM AND AFTER -HOUR <br />DEPOSITORY. IN THE EVENT THE ATM OR AFTER -HOUR DEPOSITORY <br />IS LOCATED WITHIN TEN (10) FEET OF THE CORNER OF THE <br />BUILDING AND IS GENERALLY ACCESSIBLE FROM THE ADJACENT <br />SIDE, THERE SHALL BE A MINIMUM OF TWO (2) FOOT-CANDLE <br />POWER ALONG THE FIRST FORTY (40) UNOBSTRUCTED FEET OF THE <br />ADJACENT SIDE OF THE BUILDING. <br />C. 24-HR VESTIBULE: IF THE ATM OR AFTER -HOUR DEPOSITORY IS <br />LOCATED INSIDE AN ACCESSIBLE VESTIBULE DURING ANY HOURS <br />OF DARKNESS, A MINIMUM OF TEN (10) FOOT-CANDLE POWER AT <br />THE FACE OF THE ATM OR AFTER -HOUR DEPOSITORY EXTENDING <br />OUTWARD FIVE (5) FEET IN ALL UNOBSTRUCTED DIRECTIONS. <br />THERE WILL BE A MINIMUM OF TWO (2) FOOT-CANDLE POWER AT <br />THE INSIDE OF THE VESTIBULE ENTRY/EXIT DOOR(S). A MINIMUM OF <br />TWO (2) FOOT-CANDLE POWER WITHIN SIXTY (60) FEET OF THE <br />VESTIBULE ENTRY/EXIT DOOR. IN THE EVENT THE VESTIBULE <br />ENTRY/EXIT DOOR IS LOCATED WITHIN TEN (10) FEET OF THE <br />CORNER OF THE BUILDING AND IS GENERALLY ACCESSIBLE FROM <br />THE ADJACENT SIDE, THERE SHALL BE A MINIMUM OF TWO (2) <br />FOOT-CANDLE POWER ALONG THE FIRST FORTY (40) <br />UNOBSTRUCTED FEET OF THE ADJACENT SIDE OF THE BUILDING. IN <br />URBAN SETTINGS FOR WHICH THERE IS NO DEFINED BANK PARKING <br />AND THE ONLY ACCESS AREA IS A PUBLIC SIDEWALK, A MINIMUM <br />TWO (2) FOOT-CANDLE POWER SHALL BE FOR THE FIRST FIVE (5) <br />UNOBSTRUCTED FEET FROM THE DOOR. THE MINIMUM <br />FOOT-CANDLE READING WILL ALSO BE LIMITED TO BANK <br />CONTROLLED PROPERTY LINES. <br />D. ASSOCIATE ENTRANCE/EXIT: A MINIMUM OF TWO (2) FOOT-CANDLE <br />POWER IN THE IMMEDIATE AREA OF THE DESIGNATED ASSOCIATE <br />ENTRANCE/EXIT TO THE FACILITY. <br />E. MEASURING PLANE: ALL LIGHTING MEASUREMENTS ARE TO BE <br />TAKEN AT 36 INCHES ABOVE THE GROUND ON A HORIZONTAL PLANE, <br />UNLESS OTHERWISE SPECIFIED BY STATE LAW OR REGULATION. <br />F. OTHER STANDARDS: THE MINIMUM STANDARD SHALL APPLY <br />UNLESS: (1) A GREATER STANDARD IS REQUIRED BY AN APPLICABLE <br />LAW FOR A PARTICULAR FACILITY LOCATION; OR (II) UNLESS THE <br />MINIMUM STANDARD WOULD VIOLATE LIGHTING RESTRICTIONS IN <br />AN APPLICABLE LAW FOR A PARTICULAR FACILITY LOCATION. IN <br />EITHER INSTANCE, THE MINIMUM STANDARD WOULD YIELD TO SUCH <br />APPLICABLE LAW. <br />SHEET NOTES: <br />1. PHOTOMETRIC VALUES ARE INTENDED FOR DESIGN AND EVALUATION <br />PURPOSES ONLY. THE POINT -BY -POINT SHOWN ON THIS SHEET IS BASED <br />ON A COMPUTER LIGHTING PROGRAM WITH APPROXIMATED <br />PARAMETERS. PHOTOMETRIC VALUES MAY VARY FROM ACTUAL FIELD <br />READINGS. <br />2. SITE LIGHTING HAS BEEN DESIGNED IN ACCORDANCE WITH BANK <br />CRITERIA. <br />EXISTING FIXTURE SHOWN AS EXISTING TO REMAIN <br />(e) AND FIXTURE SHOWN AS EXISTING TO BE <br />REPLACED (er) SHALL BE VERIFIED FOR <br />DUSK -TO -DAWN CONTROL, PROVIDE <br />DUSK -TO -DAWN CONTROL IF FOUND OTHERWISE. <br />11CL3U1N <br />Nelco Architecture, Inc. <br />Florida Certificate of Authorization <br />Number AA-26000525 <br />201 E Kennedy Blvd. <br />Suite 450 <br />Tampa, FL 33602 <br />Phone: 813-803-8707 <br />Client Representative: <br />Jones Lang LaSalle <br />Lisa Drees <br />Tel.: 813-624.4515 <br />E-Mail: lisa.drees@am.jll.com <br />Architect: <br />NELSON <br />Nelco Architecture Inc <br />Contact: Nicole Arwood <br />Tel.: 813-803-8713 <br />E-mail: narwood@nelsonww.com <br />Architect of Record: Peter Hauerstein <br />Tel.: 813-803-8726 <br />E-mail: phauerstein@nelsonww.com <br />FL LICENSE NO: AR97797 <br />MEP Engineer: <br />Infinity Engineering Group, LLC <br />Contact: Todd Stickler Ty <br />Tel.: 813-326-8407 <br />E-mail: todd@iegroup.net <br />Project NO: 10-976.00 <br />Certificate of Authorization: 27889 INFINITY FMANI.t:xnvc <br />caoU K LIA, <br />General Contractor: <br />Spartan Contracting Company <br />Contact: Kris Paterson <br />Tel.: 813-818-0932 <br />E-mail: kpaterson@spartancc.com <br />BANK OFAMERICA�® <br />ATM CAP ADD <br />ZEPHYRHILLS <br />5632 GALL BOULEVARD <br />ZEPHRYHILLS, FL 33542 <br />PROPERTY ID: <br />FL2-019 <br />NSRP VERSION: <br />3.0 <br />BULLETIN: <br />02-2019 <br />Description: <br />No: Date: <br />Issue for SD Review <br />Issue for Permit <br />08-02-2019 <br />11-26-2019 <br />ANDREW MOHR, P,E. 'f.'aL- <br />FI RF(, non •7'2n77 <br />DEC 0 9 2019 <br />PHOTOMETRIC PLAN <br />Proj. No: 19.0002502.00 Reviewed By: NJ/DB <br />Drawn By: SM Approved By: AM <br />E01v02 <br />