<br />CALCULATION SUMMARY AT 36" AFG
<br />LABEL
<br />CALCTYPE
<br />UNIT
<br />AVG
<br />MAX
<br />MIN
<br />AVG/MIN
<br />MAX/MIN
<br />NEW DRIVE -UP ATM (LANE 4) - 5FT COMPLIANCE
<br />ILLUMINANCE
<br />FC
<br />25.33
<br />30.2
<br />21.0
<br />1.21
<br />1.44
<br />SITE - 50FT COMPLIANCE
<br />ILLUMINANCE
<br />FC
<br />9.61
<br />36.7
<br />23
<br />4.18
<br />15.96
<br />KEYED NOTES:
<br />OATM FIVE FOOT COMPLIANCE AREA: A MINIMUM OF
<br />TEN (10) FOOT CANDLE POWER AT THE FACE OF
<br />THE ATM EXTENDING OUTWARD FIVE (5) FEET IN
<br />ALL UNOBSTRUCTED DIRECTIONS.
<br />O ATM FIFTY FOOT COMPLIANCE AREA: A MINIMUM OF
<br />TWO (2) FOOT CANDLE POWER EXTENDING
<br />OUTWARD IN ALL UNOBSTRUCTED DIRECTIONS
<br />FIFTY (50) FEET FROM THE FACE OF THE ATM.
<br />1. REGULATED STATES: THE FOLLOWING STATES REGULATE THE MINIMUM
<br />LIGHT LEVELS IN THE VICINITY OF AN ATM, AFTER HOUR DEPOSITORY,
<br />AND 24-HOUR VESTIBULE: AI.-Fa,t l-,MA, CALIFORNIA, CONNECTICUT,
<br />DISTRICT OF COLUMBIA, FLORIDA, GEORGIA, ILLINOIS, KANSAS,
<br />KENTUCKY, LOUISIANA, MARYLAND, MASSACHUSETTS, MISSOURI,
<br />MONTANA, NEVADA, NEW HAMPSHIRE, NEW JERSEY, NEW YORK, OREGON,
<br />RHODE ISLAND, TEXAS, WASHINGTON.
<br />2. LIGHTING CONTROLS: ALL NEW LIGHT FIXTURES SHALL BE INTEGRATED
<br />INTO EXISTING LIGHTING CONTROL SYSTEM FOR SIMULTANEOUS
<br />OPERATION. EXTERIOR LIGHTING SHALL BE IN SERVICE FROM
<br />DUSK -TO -DAWN. RECONFIGURE EXISTING LIGHTING CONTROLS AS
<br />REQUIRED.
<br />3. ILLUMINATION REQUIREMENTS: ELECTRICAL CONTRACTOR SHALL VERIFY
<br />EXISTING AND PROPOSED LIGHTING IN THE VICINITY OF AUTOMATIC
<br />TELLER MACHINES, AFTER -HOUR DEPOSITORIES AND 24-HOUR
<br />VESTIBULES COMPLY WITH BANK STANDARDS AND APPLICABLE FEDERAL,
<br />STATE, AND LOCAL CODES, RULES & REGULATIONS, ORDINANCES, AND
<br />STATUTES RELATED TO MINIMUM LIGHTING LEVELS FOR SAFETY. NOTIFY
<br />ENGINEER OF ANY DEFICIENCIES FOR CORRECTIVE ACTIONS. FOR
<br />REGULATED STATES, MINIMUM LIGHTING LEVELS SHALL MEET THE
<br />CRITERIA LISTED HEREIN:
<br />A. DRIVE -UP ATM OR NIGHT DEPOSITORY: A MINIMUM OF TEN (10)
<br />FOOT-CANDLE POWER AT THE FACE OF THE ATM OR AFTER -HOUR
<br />DEPOSITORY EXTENDING OUTWARD FIVE (5) FEET IN ALL
<br />UNOBSTRUCTED DIRECTIONS. A MINIMUM OF TWO (2) FOOT-CANDLE
<br />POWER EXTENDING OUTWARDS IN ALL UNOBSTRUCTED
<br />DIRECTIONS FIFTY (50) FEET FROM THE FACE OF THE ATM AND
<br />AFTER -HOUR DEPOSITORY.
<br />B. WALK-UP ATM OR NIGHT DEPOSITORY: A MINIMUM OF TEN (10)
<br />FOOT-CANDLE POWER AT THE FACE OF THE ATM OR AFTER -HOUR
<br />DEPOSITORY EXTENDING OUTWARD FIVE (5) FEET IN ALL
<br />UNOBSTRUCTED DIRECTIONS. A MINIMUM OF TWO (2) FOOT-CANDLE
<br />POWER WITHIN SIXTY (60) FEET OF THE ATM AND AFTER -HOUR
<br />DEPOSITORY. IN THE EVENT THE ATM OR AFTER -HOUR DEPOSITORY
<br />IS LOCATED WITHIN TEN (10) FEET OF THE CORNER OF THE
<br />BUILDING AND IS GENERALLY ACCESSIBLE FROM THE ADJACENT
<br />SIDE, THERE SHALL BE A MINIMUM OF TWO (2) FOOT-CANDLE
<br />POWER ALONG THE FIRST FORTY (40) UNOBSTRUCTED FEET OF THE
<br />ADJACENT SIDE OF THE BUILDING.
<br />C. 24-HR VESTIBULE: IF THE ATM OR AFTER -HOUR DEPOSITORY IS
<br />LOCATED INSIDE AN ACCESSIBLE VESTIBULE DURING ANY HOURS
<br />OF DARKNESS, A MINIMUM OF TEN (10) FOOT-CANDLE POWER AT
<br />THE FACE OF THE ATM OR AFTER -HOUR DEPOSITORY EXTENDING
<br />OUTWARD FIVE (5) FEET IN ALL UNOBSTRUCTED DIRECTIONS.
<br />THERE WILL BE A MINIMUM OF TWO (2) FOOT-CANDLE POWER AT
<br />THE INSIDE OF THE VESTIBULE ENTRY/EXIT DOOR(S). A MINIMUM OF
<br />TWO (2) FOOT-CANDLE POWER WITHIN SIXTY (60) FEET OF THE
<br />VESTIBULE ENTRY/EXIT DOOR. IN THE EVENT THE VESTIBULE
<br />ENTRY/EXIT DOOR IS LOCATED WITHIN TEN (10) FEET OF THE
<br />CORNER OF THE BUILDING AND IS GENERALLY ACCESSIBLE FROM
<br />THE ADJACENT SIDE, THERE SHALL BE A MINIMUM OF TWO (2)
<br />FOOT-CANDLE POWER ALONG THE FIRST FORTY (40)
<br />UNOBSTRUCTED FEET OF THE ADJACENT SIDE OF THE BUILDING. IN
<br />URBAN SETTINGS FOR WHICH THERE IS NO DEFINED BANK PARKING
<br />AND THE ONLY ACCESS AREA IS A PUBLIC SIDEWALK, A MINIMUM
<br />TWO (2) FOOT-CANDLE POWER SHALL BE FOR THE FIRST FIVE (5)
<br />UNOBSTRUCTED FEET FROM THE DOOR. THE MINIMUM
<br />FOOT-CANDLE READING WILL ALSO BE LIMITED TO BANK
<br />CONTROLLED PROPERTY LINES.
<br />D. ASSOCIATE ENTRANCE/EXIT: A MINIMUM OF TWO (2) FOOT-CANDLE
<br />POWER IN THE IMMEDIATE AREA OF THE DESIGNATED ASSOCIATE
<br />ENTRANCE/EXIT TO THE FACILITY.
<br />E. MEASURING PLANE: ALL LIGHTING MEASUREMENTS ARE TO BE
<br />TAKEN AT 36 INCHES ABOVE THE GROUND ON A HORIZONTAL PLANE,
<br />UNLESS OTHERWISE SPECIFIED BY STATE LAW OR REGULATION.
<br />F. OTHER STANDARDS: THE MINIMUM STANDARD SHALL APPLY
<br />UNLESS: (1) A GREATER STANDARD IS REQUIRED BY AN APPLICABLE
<br />LAW FOR A PARTICULAR FACILITY LOCATION; OR (II) UNLESS THE
<br />MINIMUM STANDARD WOULD VIOLATE LIGHTING RESTRICTIONS IN
<br />AN APPLICABLE LAW FOR A PARTICULAR FACILITY LOCATION. IN
<br />EITHER INSTANCE, THE MINIMUM STANDARD WOULD YIELD TO SUCH
<br />APPLICABLE LAW.
<br />SHEET NOTES:
<br />1. PHOTOMETRIC VALUES ARE INTENDED FOR DESIGN AND EVALUATION
<br />PURPOSES ONLY. THE POINT -BY -POINT SHOWN ON THIS SHEET IS BASED
<br />ON A COMPUTER LIGHTING PROGRAM WITH APPROXIMATED
<br />PARAMETERS. PHOTOMETRIC VALUES MAY VARY FROM ACTUAL FIELD
<br />READINGS.
<br />2. SITE LIGHTING HAS BEEN DESIGNED IN ACCORDANCE WITH BANK
<br />CRITERIA.
<br />EXISTING FIXTURE SHOWN AS EXISTING TO REMAIN
<br />(e) AND FIXTURE SHOWN AS EXISTING TO BE
<br />REPLACED (er) SHALL BE VERIFIED FOR
<br />DUSK -TO -DAWN CONTROL, PROVIDE
<br />DUSK -TO -DAWN CONTROL IF FOUND OTHERWISE.
<br />11CL3U1N
<br />Nelco Architecture, Inc.
<br />Florida Certificate of Authorization
<br />Number AA-26000525
<br />201 E Kennedy Blvd.
<br />Suite 450
<br />Tampa, FL 33602
<br />Phone: 813-803-8707
<br />Client Representative:
<br />Jones Lang LaSalle
<br />Lisa Drees
<br />Tel.: 813-624.4515
<br />E-Mail: lisa.drees@am.jll.com
<br />Architect:
<br />NELSON
<br />Nelco Architecture Inc
<br />Contact: Nicole Arwood
<br />Tel.: 813-803-8713
<br />E-mail: narwood@nelsonww.com
<br />Architect of Record: Peter Hauerstein
<br />Tel.: 813-803-8726
<br />E-mail: phauerstein@nelsonww.com
<br />FL LICENSE NO: AR97797
<br />MEP Engineer:
<br />Infinity Engineering Group, LLC
<br />Contact: Todd Stickler Ty
<br />Tel.: 813-326-8407
<br />E-mail: todd@iegroup.net
<br />Project NO: 10-976.00
<br />Certificate of Authorization: 27889 INFINITY FMANI.t:xnvc
<br />caoU K LIA,
<br />General Contractor:
<br />Spartan Contracting Company
<br />Contact: Kris Paterson
<br />Tel.: 813-818-0932
<br />E-mail: kpaterson@spartancc.com
<br />BANK OFAMERICA�®
<br />ATM CAP ADD
<br />ZEPHYRHILLS
<br />5632 GALL BOULEVARD
<br />ZEPHRYHILLS, FL 33542
<br />PROPERTY ID:
<br />FL2-019
<br />NSRP VERSION:
<br />3.0
<br />BULLETIN:
<br />02-2019
<br />Description:
<br />No: Date:
<br />Issue for SD Review
<br />Issue for Permit
<br />08-02-2019
<br />11-26-2019
<br />ANDREW MOHR, P,E. 'f.'aL-
<br />FI RF(, non •7'2n77
<br />DEC 0 9 2019
<br />PHOTOMETRIC PLAN
<br />Proj. No: 19.0002502.00 Reviewed By: NJ/DB
<br />Drawn By: SM Approved By: AM
<br />E01v02