h 3" DIAMETER MIN, i <br />TOP LEG BARS <br />1/32"RD, PLAIN BAR EACH <br />LEG UP TO 144" LENGTHS <br />3/8"RD, REBAR EACH LEG <br />OVER 14'-8" LENGTHS <br />1/32" STIRRUPS 4'-0" O.G. <br />LENGTHS OVER 144" <br />TIED OR WELDED <br />'A' BARS (MAIN REINF.) <br />SEE SCHEDULE <br />'B' BARS SEE SCHEDULE <br />PRE CAST CONCRETE <br />TYPICAL LINTEL SECTION <br />SAFE LOAD TABLE FOR CAST-CRETE <br />HIGH STRENGTH <br />PRECAST AND PRESTRESSED V LINTELS <br />SAFE LOAD -POUNDS PER LINEAR FOOT <br />LENGTH <br />UNFILLED <br />FILLED <br />a <br />4'-0" (48") PRECAST <br />1,815 LBS, <br />6,049 LBS. <br />b <br />4'-6" (54") PRECAST <br />1,950 LBS, <br />4,815 LBS. <br />c <br />5'-4" (64") PRECAST <br />1143 LBS, <br />4,615 LBS, <br />d <br />5'-10" (10") PRECAST <br />1515 LBS. <br />3144 LBS. <br />e <br />fo'-6" (18") PRECAST <br />1565 LBS, <br />3,260 LBS. <br />f <br />1'-6" (50") PRECAST <br />1550 LBS, <br />2 91 LBS. <br />9'4' (112") PRECAST <br />1025 LBS. <br />1141 LBS. <br />h <br />10'-6" (126") PRECAST <br />922 LBS. <br />1,333 LBS. <br />t <br />ll'-4" (136") PRECAST <br />800 LBS, <br />1019 LBS. <br />12'-0" (144") PRECAST <br />150 LBS, <br />9O9 LISS. <br />k <br />13'-4" (160") PRECAST <br />651 LBS, <br />1.341 LBS. <br />m <br />14'-0" (169") PRECAST <br />585 LBS, <br />9O9 LBS. <br />n <br />14'-8" 016") PRESTRESSED <br />563 LBS. <br />1,341 LBS. <br />o <br />15'-4" (184") PRESTRESSED <br />510 LBS, <br />1210 LBS. <br />q <br />1 EA <br />*5 BAR <br />CONT, FROM <br />POURED SOLID <br />FTG TO LINTEL <br />�- <br />TYPICAL C.M.U. WALL REINFORCING <br />j. <br />FILLED CELL <br />1/32"RD, PLAIN BAR EACH <br />1/32" PLAIN STIRRUPS <br />(POSITIONERS) 4'-0" O.C. <br />TIED OR WELDED <br />2 STRANDS, 1/16", 1 WIRE <br />STRESS RELIEVED 150 K34 <br />PRE -STRESSING CABLE <br />'A' BARS PER SCHEDULE <br />PRE STRESSED CONCRETE <br />PRE -STRESSED <br />REINFORCING SCHEDULE AND LOAD CAPACITIES <br />LINTEL <br />LENGTH <br />CLEAR <br />SPAN <br />'A' BAR <br />SCHEDULE <br />MAX. SAFE LOAD <br />LINTEL ONLY <br />SAFE LOAD ON <br />COMPOSITE <br />ah <br />14'-8" <br />13'-4" <br />NONE <br />550 <br />*/FT. <br />1,900 <br />*/Ft. <br />at <br />15'4' <br />14'-0" <br />NONE <br />650 <br />*/FT. <br />1,810 <br />*/FT. <br />aJ <br />IT-4" <br />ib'-O" <br />*4RD. BARS <br />510 <br />*/FT, <br />1,580 <br />*/FT. <br />ak <br />19'4' <br />18'-O" <br />2 - *5RD. BARS <br />500 <br />*/FT. <br />1,400 <br />*/FT. <br />am <br />20'-0" <br />18'-8" <br />2 - *5RD. BARS <br />425 <br />*/FT. <br />1,400 <br />*/FT. <br />an <br />22'-0" <br />204" <br />2 - *5RD. BARS <br />390 <br />*/FT. <br />1,220 <br />*/FT. <br />ao <br />24'-0" <br />22'-8" <br />2 - *5RD. BARS <br />320 <br />*/FT. <br />1,120 <br />*/FT. <br />(1) *5 BARS IF TRUS' <br />"GIRDER" IS SUPPORTED <br />BY LINTEL GREATER <br />THAN 8'-0" <br />11'-4" (208") PRESTRESSED 381 LBS. 911 LBS. (1) *5 BARS IF TRUSS - <br />19'-4" (232") PRESTRESSED 289 LBS. 823 LBS. GIRDER IS SUPPORTED <br />BY LINTEL <br />REINFORCING SCHEDULE AND LOAD CAPACITIES <br />LINTEL <br />BAR <br />CLEAR <br />BOTTOM REINFORCMENT BARS <br />MAX. SAFE LOAD <br />SAFE LOAD ON <br />LENGTH <br />LENGTH <br />SPAN <br />'A' MAIN BARS 'B' BARS <br />LINTEL ONLY <br />COMPOSITE <br />r <br />2'-10" <br />21-8" <br />11-6" <br />2 - 1/32" NONE <br />1,000 + */FT, <br />3,000 + */FT. <br />31-6" <br />3'-4" <br />2'-2" <br />PLAIN BAR ENDS <br />t <br />41-0" <br />3'-10" <br />21-8" <br />HOOKED UP SOD. <br />4'-6" <br />4'-4" <br />3'-2" <br />FOR 2-1/2" <br />51-611 <br />51-21 <br />41-01' <br />2 - *3RD. NONE <br />1,000 + */FT. <br />2,100 + */FT. <br />5- 10 <br />I' <br />5-811 <br />4-611 <br />� <br />1 <br />11-O" <br />6'4" <br />2 - *4RD. NONE <br />800 + */FT, <br />2,250 + */FT, <br />as <br />8'-4" <br />1'-loll <br />1'-0" <br />ab <br />9'-4" <br />8'-10" <br />8'-O" <br />2 - *5RD. NONE <br />800 + */FT. <br />2,000 + */FT. <br />10'-6" <br />10--0" <br />9'4" <br />1l'-4" <br />10'-10" <br />10'-O" <br />2 - *5RD. 2 - *3RD. <br />800 */FT. <br />2,000 */FT. <br />as <br />12'-6" <br />12'-0" <br />ll'-2" <br />100 */FT. <br />1,800 */FT. <br />of <br />13'-4" <br />12'-10" <br />121-0" <br />650 */FT, <br />IAOO */FT. <br />as <br />14'-0" <br />13'-6" <br />12'-8" <br />600 */FT. <br />1,100 */FT, <br />ABOVE INFORMATION IS BASED ON CAST-CRETE (FECP CORP.) BRAND LINTELS. <br />BASED ON TESTS CONDUCTED BY WERTHER F. ROSCH, P.E. <br />PRECAST LINTELS MAY BE CAST CRETE OR OTHER BUILDING CODE APPROVED <br />PRECAST MANUFACTURERS. <br />(1) *5 REBAR CONTINUOUS <br />— CONC. KNOCKOUT BLOCK <br />— CELLS AND V LINTEL FILLED W/GONG. <br />(3000) PSI AT 28 DAYS) <br />— PRE CAST / PRE STRESSED 'U' LINTEL (SEE DETAIL) <br />*4 BAR ADDED THROUGH V LINTEL TO <br />SUPPORTS IN SPANS GREATER THAN 12'-0" <br />SON HD2A <br />S IMPSON 8101 <br />TYPICAL >,--IOLDOWN <br />INSTALLATION <br />NTS <br />SPECIFICATIONS <br />1. BAR STEEL SHALL BE MIN, GRADE 40, DEFORMED EXCEPT SAWED JOINT -FILL JOINT <br />LEVEL WITH JOINT FILLER <br />WHERE PLAIN BARS (HOOKED FOR BOND ANCHORAGE) ARE <br />SPECIFICALLY PERMITTED. <br />2. CONCRETE IN PRE CAST MEMBERS TO BE MIN, 4000 PSI AT SYNTHETIC FIBER REINFORCING <br />28 DAYS. v <br />COMPOSITE LINTEL SECTION <br />(STANDARD FOR TRUSS "GIRDER" LINTELS) <br />MAX. UPLIFT - 10,000 Iba, CONTROL JOINT <br />SEE PLANS FOR <br />A,B, REQUIREMENTS <br />(OPTION) <br />2 S I MPSON <br />H4's <br />TYPICAL H4 OR 8101 <br />INSTALLATION <br />NTS <br />BOND BEAM COURSE <br />EVERY 60" O.C. (TYP.) <br />HORIZONTAL STEEL <br />IN BOND BEAM <br />SCREENMUNDERBO RBW11e <br />TO CONFINE GROUT <br />VERTICAL NTEEL <br />INING STEEL ARE <br />-Y_ WITH GROUT: <br />DROPPINGS, AND AT LEAST <br />1 1/2" X 2" IN SIZE (TYP.) <br />PLACE MORTAR ON CROSS <br />WEBS ADJACENT TO CELLS <br />THAT WILL BE GROUTED <br />TO FORM DAMS <br />TYPICAL WALL WITH RODS PLACEMENT <br />N. <br />NOTES: CONTROL JOINTS <br />1LOCATE JOINS AT SUCH INTERVALS THAT THE MAXIMUM SLAB <br />AREA BETWEEN THESE JOINTS DOES NOT EXCEED 400 SQUARE FEET. <br />ANY CONTROL JOINTS LOCATED ON THE FOUNDATION PLAN ARE A MINIMUM. <br />2) SAWCUT JOINTS MUST BE MADE AS SOON AS POSSIBLE AFTER THE <br />SURFACE IS FIRM ENOUGH BUT NO LATER THAN TWELVE HOURS AFTER <br />PLACEMENT. <br />SLAB ON GRADE JOINTDETAILS <br />SCALE: 3/4" - 1'-0" <br />*5 VERTICAL WALL REINFORCING SEE WALL SECTION FOR <br />IN GROUTED CELLS SPECIFICATIONS IN THIS ARE <br />BOND BEAM A.C.I, SO STANDARD <br />HOOK- EMBED 6" <br />Fu <br />� g <br />JE <br />W FILLED cm-L <br />} <br />*5 HORIz. <br />U ILu REBAR CONT. <br />Id <br />U w <br />� N <br />U <br />z <br />CA <br />SEE WALL SECTION FO <br />SPECIFICATIONS IN THI <br />L5EARING <br />FOOTER <br />SEE FOUNDATION PLAN FOR <br />FOOTER SIZE 4 REBAR PLACEMENT <br />MASONRY WALL <br />FILLED CELL DETAIL <br />N.T,S. <br />>% o <br />cc w w Ld <br />N Z(L p0 Qp LLuj <br />'z'" JZ oil 3 <br />uLLLL " QQ� �u CL <br />G_ tAQQ z U <br />Lu z �4r-yes <br />V) i~wZZ <br />�- <br />,w �•�Q <br />N,,, o _ o <br />•U. <br />.• a rt ;yam <br />t ' • 4 <br />too <br />Q� o = <br />W Z <br />Q� <br />lu L <br />"- 1-- Q <br />to C4 <br />(y (3 u 4 <br />O lu <br />z }�� <br />z <br />• Q� <br />O 0 LL � <br />Q a <br />W dIt <br />W <br />A <br />0 <br />0 <br />d) <br />r2 <br />j o <br />z � <br />a <br />Q <br />m <br />z <br />zLa <br />M <br />� � <br />IL <br />Lu <br />U <br />z uj <br />Lu <br />UJ <br />Lu uj <br />z <br />•• z <br />AREA Lu <br />Z <br />Q <br />SHEET NO. <br />z DETAIL'S <br />� O <br />0 <br />