MODEL 611005701 78"x78" NON -PENETRATING
<br />SATELLITE SLED MOUNT WITH NON -SLIP
<br />RUBBER PAD SUPPLIED BY VSAT INSTALLER.
<br />z
<br />O
<br />F—
<br />J
<br />Q
<br />z
<br />Orr
<br />zw
<br />¢_j
<br />J
<br />m
<br />Uz
<br />QQ
<br />d>
<br />Om
<br />GENERAL CONTRACTOR TO
<br />PROVIDE ROOF PENETRATION
<br />AS NEEDED.
<br />0
<br />z
<br />�W
<br />0" 1-1/4" CONDUIT & PULL
<br />0 Q STRING BY GENERAL
<br />CONTRACTOR
<br />Q
<br />COAXIAL CABLE BY
<br />VSAT INSTALLER
<br />RECEIVINGTHE FINAL
<br />DMARC BY TO E INTO LABEL ENDS WITH
<br />LOCAL PHONE COMPANY YELLOW PHASING TAPE
<br />AREAAIIlllill
<br />DMARC
<br />MOUNT ON WALL WITHIN ONE
<br />�- FOOT OF DMARC (BY G.C.
<br />® LABEL END WITH % ® PRIOR TO TURNOVER)
<br />YELLOW PHASING
<br />TAPE
<br />DSL
<br />(2) RJ-45 DATA JACK
<br />IIIIIIII IIIIIIII
<br />IIII IIII =
<br />(2) RJ-11 PHONE JACK
<br />® —
<br />COMBO IN OFFICE
<br />SUPPLIED WITH
<br />s
<br />®,5/1
<br />TERMINAL CONNECTION ���IlIIIIIIl11111lIIIIIl111IIIlfllIII1!l1111II1311111111IIIIIIUlI11111114
<br />RJ-11 PHONE JACK
<br />LABEL END WITH
<br />Z
<br />YELLOW PHASING
<br />TAPE
<br />F ji a
<br />Alk Mlk ANIL
<br />2" CONDUIT AND PULL STRING BY LABEL END WITH
<br />GENERAL CONTRACTOR BROWN PHASING TAPE
<br />#1 CONDUIT TO
<br />ABOVE OFFICE
<br />CEILING
<br />1111 II HIIIIIIIIIIIIII1111111111111111HIM 1111111111111111111111111111111111111111HIM IIIIIIIIIIIIIIIIIIIIIIII31II11111111111111111111
<br />B� #2 CONDUIT TO
<br />r ABOVE OFFICE
<br />CEILING
<br />1" CONDUIT & PULL STRING
<br />BY GENERAL CONTRACTOR
<br />LABEL END WITH
<br />YELLOW PHASING TAPE
<br />Eck VSAT
<br />1111IIIIII(D Box
<br />SUPPLIED AND INSTALLED BY
<br />VSAT INSTALLER IN OFFICE
<br />REQUIRED ACCOUNT VENDORS
<br />COMPANY
<br />CONTACTS
<br />PHONE #
<br />LOW VOLTAGE & VOICE/DATA
<br />CROSSCOM NATIONAL
<br />ANDREA LEMAY
<br />847-850-6297
<br />dollargeneral@crosscomnational.com
<br />CO, CT, DE, FL, IA, IL, IN, KS, MA, MD, ME, MI, MN, MO,
<br />ND, NE, NH, NJ, NY, OH, PA, RI, SD, VT, WI, WV
<br />ASD
<br />828-624-1046
<br />CHRIS RUDNITSKI
<br />crudnitski@asd-usa.com
<br />AL, AR, AZ, CA, GA, KY, LA, MS, NC, NM, NV, OK, OR,
<br />SC, TN, TX, VA
<br />NOTE:
<br />c�
<br />z
<br />J
<br />FW
<br />0
<br />Z J
<br />Q
<br />uj
<br />U cn
<br />>
<br />0
<br />m
<br />Q
<br />�0113 Q41 11111"iff-d-, ed lo�lan"l��������l��������������������I �w X
<br />REGISTER AREA
<br />LAYOUT VARIES
<br />MOUNT J-BOX AT 12'
<br />1" CONDUIT AND PULL STRING BY
<br />GENERAL CONTRACTOR
<br />PROVIDE 20 FEET OF SERVICE CABLE
<br />COILED AT CENTER OF SALES FLOOR
<br />WITH SURFACE MOUNT RJ45 JACK
<br />r f, ��
<br />aR?i{6�s�ll k��iG
<br />t J i
<br />a
<br />24 PORT DATA PATCH PANEL
<br />MOUNTED ON BRACKET ABOVE THE DATA HUB IN OFFICE.
<br />a(31
<br />dk
<br />im
<br />D - LINK DSS - 16 PORT DATA HUB
<br />LOCATED IN THE OFFICE, SUPPLIED AND INSTALLED
<br />BY THE DOLLAR GENERAL STORE OPENING TEAM.
<br />*ALL CABLES ARE REQUIRED TO BE TESTED FOR
<br />CONTINUITY AT TIME OF INSTALLATION.
<br />LABEL ENDS WITH
<br />RED PHASING TAPE
<br />CONDUIT RESPONSIBILITY
<br />o
<br />z I LUIVUUI I& I-'ULL J 1 KIINU
<br />C) BY GENERAL CONTRACTOR
<br />°zw
<br />Uco
<br />w
<br />0
<br />m
<br />a
<br />BUNDLE ALL CABLES TOGETHER
<br />AND PENETRATE THE OFFICE
<br />CEILING GRID AT ONE LOCATION
<br />DIRECTLY ABOVE THE DATA
<br />PATCH PANELS. FIELD VERIFY
<br />EXACT LOCATION.
<br />CONDUIT
<br />START
<br />END
<br />SIZE
<br />CONDUIT RESPONSIBILITY
<br />*CABLING RESPONSIBILITY
<br />NUMBER
<br />1
<br />RECEIVING AREA
<br />OFFICE (HUB)
<br />2"
<br />GENERAL CONTRACTOR
<br />LOW VOLTAGE VENDOR
<br />2
<br />OFFICE
<br />OFFICE (HUB)
<br />1"
<br />GENERAL CONTRACTOR
<br />LOW VOLTAGE VENDOR
<br />VOICE / DATA PORT
<br />3
<br />SALES FLOOR
<br />OFFICE (HUB)
<br />1"
<br />GENERAL CONTRACTOR
<br />LOW VOLTAGE VENDOR
<br />REGISTER CONNECTION
<br />SALES FLOOR
<br />4
<br />QUADRANT
<br />OFFICE (HUB)
<br />1"
<br />GENERAL CONTRACTOR
<br />LOW VOLTAGE VENDOR
<br />CONNECTION
<br />5
<br />SATELLITE
<br />OFFICE (HUB)
<br />1-1/4"
<br />GENERAL CONTRACTOR
<br />LOW VOLTAGE VENDOR
<br />*UNLESS OTHERWISE NOTED, ALL RESPONSIBILITIES SHOULD FOLLOW THIS CHART.
<br />ALL LOW VOLTAGE WIRING INSTALLED IN CABLE TRAY FOR OPEN CEILING LAYOUTS.
<br />2" CONDUIT FROM
<br />RECEIVING TO DATA
<br />VOICE PORT
<br />1-1/4" CONDUIT
<br />FROM SATELLITE
<br />TO OFFICE HUB -
<br />VOICE / DATA POR
<br />1" CONDUIT FROM
<br />VOICE DATA PORT
<br />TO OFFICE HUB AT
<br />EQUIPMENT MAP -
<br />OFFICE HUB AT
<br />EQUIPMENT MAP
<br />ALL CABLES AT THE OFFICE WILL
<br />NEED TO BE WRAPPED IN PHASING
<br />TAPE CONSISTENT WITH THE FOLLOWING
<br />COLORS:
<br />RED TAPE
<br />CASH REGISTER DATA
<br />BLUE TAPE ELEC. EMS DATA
<br />BROWN TAPE OFFICE DATA
<br />ELECTRICAL, DMARC AND EMS
<br />PANELS IN RECEIVING AREA.
<br />1" CONDUIT FROM
<br />SALES FLOOR
<br />QUADRANTS TO
<br />OFFICE HUB
<br />1" CONDUIT FROM
<br />SALES REGISTER
<br />CONNECTION TO
<br />OFFICE HUB
<br />TYPICAL FLOOR PLAN
<br />NOT TO SCALE
<br />ORANGE TAPE COOLER/FREEZER EMS DATA
<br />YELLOW TAPE PHONE CABLE TO DMARC
<br />Wire Symbols
<br />RJ-45: 24 GA., 4 TWISTED PAIR,
<br />CATEGORY -FIVE (CAT 5) DATA CABLE
<br />WITH MODULAR RJ-45 END.
<br />RJ-11: 24 GA., 4 TWISTED PAIR,
<br />CATEGORY -FIVE (CAT 5) DATA
<br />CABLE WITH MODULAR RJ-11 END.
<br />USE ONLY THE BLUE & WHITE AND
<br />SOLID BLUE WIRES. ALL OTHER
<br />WIRES TO BE FOLDED BACK AND
<br />TAPED TO THE CABLE.
<br />COAXIAL CABLE WITH RF
<br />CONNECTOR
<br />GENERAL CONTRACTOR NOTE:
<br />EXPANSIONS AND RELOCATIONS REQUIRE THE
<br />GENERAL CONTRACTOR TO PROVIDE THE MATERIALS
<br />AND LABOR INDICATED ON THIS DIAGRAM AS BY "LOW
<br />VOLTAGE INSTALLER" IN ADDITION TO CONDUITS
<br />INDICATED. DOLLAR GENERAL DOES NOT PROVIDE
<br />AND/OR INSTALL THE LOW VOLTAGE AND DATA
<br />CABLING ON THOSE PROJECTS.
<br />DATA CABLING SCHEMATIC
<br />NOT TO SCALE
<br />PROPOSE
<br />D
<br />LOCATION:
<br />ZEPHYRHILLS
<br />FL
<br />5931 GALL BLVID.
<br />REVISED
<br />BY:
<br />Sim ----
<br />0
<br />W0
<br />W
<br />4-a
<br />M
<br />W ����
<br />co
<br />0
<br />o
<br />�0Z
<br />J
<br />L0
<br />LO
<br />LO
<br />C,6 2
<br />T_
<br />CD
<br />Q O
<br />0
<br />0
<br />0
<br />DATE:
<br />5/30/2018
<br />SCALE:
<br />N.T.S.
<br />SHEET NO:
<br />E3
<br />
|