Laserfiche WebLink
BUILDING SIGNS <br />SIGN SIZE <br />SIGN WT. <br /># OF CKTS. <br />AMPS <br />VOLTS <br />3'x23' BOX <br />380 LBS. <br />(1) 15 A <br />2.5 <br />115 <br />3'-9"x26' BOX <br />441 LBS. <br />(1) 15 A <br />5 <br />115 <br />4'-6"x33'-3" BOX <br />750 LBS. <br />(1) 15 A <br />8.4 <br />115 <br />5'x40' BOX <br />1220 LBS. <br />(1) 15 A <br />10 <br />115 <br />BUILDING LETTERS <br />SIGN SIZE <br />SIGN WT. <br /># OF CKTS. <br />AMPS <br />VOLTS <br />18" <br />215 LBS. <br />(2) 15 A <br />19.6 <br />115 <br />24" <br />288 LBS. <br />(1) 15 A & (1) 20 A <br />23.45 <br />115 <br />30" <br />387 LBS. <br />(2) 20 A <br />28 <br />115 <br />36" <br />649 LBS. <br />(2) 15 A & (1) 20 A <br />32.9 <br />115 <br />REQUIRED NATIONAL ACCOUNT VENDORS <br />COMPANY <br />NATIONAL CONTACT <br />PHONE # / EMAIL <br />BUILDING SIGNS, BUILDING LETTERS, PYLON SIGNS <br />DUALITE SALES <br />ROSE SHINKLE <br />513-724-7100 <br />(AR, IA, IL, IN, KY, KS, LA, MI, MN, MO, MS, OH, <br />& SERVICE <br />(SR. PROJECT MANAGER) <br />rshinkle@dualite.com <br />OK, TN,TX,WI) <br />SIGN RESOURCE <br />IDENTITY GROUP <br />ANGII HEIDBRINK <br />323-485-4720 <br />(AZ, CA, CO, NE, NM,NV, SD, UT, WY) <br />EVERBRITE <br />CHRISTINE OLSON <br />414-427-2329 <br />(AL, CT, DE, FL, GA, MA, MD, ME, NC, NH, NJ, <br />NY, PA, RI, SC, VA, VT, WV) <br />NATIONAL ACCOUNT & CONTACT INFORMATION SUBJECT TO CHANGE <br />LINE #1 WILL HAVE TWO RJ-11 JACKS. ONE <br />AT REGISTER, SECOND IN THE OFFICE. LABEL <br />AS PHONE. ALL PHONE JACKS REQUIRE A <br />BLUE SEPARATE 24 ga. CAT 5,4 PAIR HOME RUN TO <br />& DMARC. NOTE SEPARATE GROUND WIRES. REFER <br />BLUE/WHITE TO SHEET E-3 FOR DETAILS. <br />BUZZER - TORK MODEL #TA725 W/TRANSFORMER MODEL <br />#TA592. <br />COMMERCIAL GRADE PUSH BUTTON <br />(p <br />125V NEMA 5-20R DUPLEX <br />(p <br />125/250V NEMA L14-20-R 4 PRONG TWIST LOCK <br />125V NEMA 5-20R QUAD <br />'-❑ <br />DISCONNECT <br />I <br />POWER POLE -BLACK MAGIC <br />v <br />PHONE JACK @REGISTER <br />O <br />VOICE/DATA PORT = RJ-111 RJ-45 DATA JACK, PHONE <br />COMBO @OFFICE <br />$nn <br />PROVIDE OCCUPANCY LIGHT SENSOR - LEVITON ODS 10-IDW <br />20 AMP TOGGLE SWITCH <br />NL <br />NIGHT LIGHT CIRCUIT <br />ELECTRICAL SPECIFICATIONS: <br />ALL EXPOSED WIRING SHALL BE CONTAINED IN CONDUIT OF PROPER SIZE. <br />2. ALL WIRING SHALL CONFORM TO LOCAL, STATE, AND FEDERAL CODES. <br />3. ELECTRICAL SERVICE TO BE MINIMUM 400 AMP, 3-PHASE (PREFERRED) OR 600 AMP, <br />SINGLE PHASE OR LARGER IF REQUIRED BY CODE OR ELECTRICAL LOAD. <br />4. REGISTER POWER POLES - VERIFY REGISTER CONFIGURATION ON FINAL FIXTURE PLAN <br />BEFORE ORDERING AND INSTALLATION OF ELECTRICAL COMPONENTS. CUSTOM BUILT <br />POWER POLE ASSEMBLY AVAILABLE FROM D&P CUSTOM LIGHTS & PRODUCTS INC. <br />PHONE # (800) 251-2200 OR (615) 350-7800, 7111 COCKRILL BEND INDUSTRIAL ROAD. <br />NASHVILLE, TN 37209 <br />EXTERIOR EXPOSED PHONE LINES TO BE INSTALLED IN RIGID CONDUIT. PROVIDE <br />EMERSON 3/4" x 5-FT. METALLIC CABLE U-GUARD #755 OR EQUAL. <br />6. ELECTRIC PANELS TO BE LABELED CORRECTLY WITH LEGIBLE PRINT. <br />7. LOW VOLTAGE VENDOR TO PROVIDE AND INSTALL ONE (1) 24 GA., 4 TWISTED -PAIR, <br />CATEGORY -FIVE (CAT5) DATA CABLE WITH MODULAR COMBO RJ-11/RJ/45 JACK AT <br />MANAGER'S OFFICE. CABLE TO BE RUN FROM JACK TO DATA HUB LOCATION WITH 6'-0" <br />LEFT COILED FOR INSTALLATION TO DATA HUB. A RJ-45 MALE FITTING SHOULD BE <br />CRIMPED ON THIS END. DOLLAR GENERAL STORE OPENING TEAM WILL MAKE FINAL <br />CONNECTION INTO THE DATA HUB. <br />8. SEE SHEET F1 FOR COOLER/FREEZER OPTIONS. VERIFY FINAL LOCATION AND NW <br />OF COOLERS AND FREEZERS ON FINAL FIXTURE PLAN BEFORE ORDERING AND <br />INSTALLATION OF ELECTRICAL COMPONENTS. EACH COOLER REQUIRES A 20 AMP <br />DEDICATED GROUND CIRCUIT TO BE USED FOR A 110v OUTLET. EACH OF THESE U <br />DRAW 12 AMPS. EACH FREEZER REQUIRES ONE - 125/250V OUTLET NEMA #L14-20 <br />PRONG TWIST LOCK. EACH UNIT DRAWS 16 AMPS. TWO DOOR FREEZER IN RECEI <br />AREA REQUIRES ONE 125/250V NEMA 14-20R OUTLET ON A 20 AMP DEDICATED CIR <br />UNIT DRAWS 8 AMPS. <br />PYLON SIGNS <br />SIGN SIZE <br />SIGN WT. <br /># OF CKTS. <br />AMPS <br />VOLTS <br />4'x8' <br />188 LBS. <br />(1) 15 A <br />1.7 <br />115 <br />5'x10' <br />375 LBS. <br />(1) 15 A <br />3.4 <br />115 <br />6'x16' <br />738 LBS. <br />(1) 15 A <br />5 <br />115 <br />NOTES: <br />1. PROVIDE AND INSTALL CONDUIT, JUNCTION BOXES, D&P CONNECTORS <br />AND/OR POWER POLE(S) FOR CASH REGISTER(S) PER TENANT'S <br />CRITERIA PLANS, VERIFY LOCATION OF JUNCTION BOXES WITH <br />TENANT'S FIXTURE FLOOR PLAN PROVIDED BEFORE TURNOVER DATE. <br />2. PROVIDE AND INSTALL POWER POLE(S) FOR REGISTERS AND ICE CREAM <br />FREEZER PER TENANT'S CRITERIA PLANS. <br />3. PROVIDE AND INSTALL POWER POLES FOR REFRIGERATION UNITS PER <br />TENANT'S CRITERIA PLANS. <br />4. VERIFY LOCATION OF POWER POLES WITH TENANT'S FIXTURE FLOOR <br />PLAN PROVIDED BEFORE TURNOVER DATE. <br />5. PROVIDE AND INSTALL ELECTRICAL RECEPTACLES PER TENANT'S <br />CRITERIA PLANS. <br />6. PROVIDE AND INSTALL BREAKER LOCKS ON THE FOLLOWING: <br />REGISTER POWER POLES, SALES FLOOR COOLERS AND FREEZERS, <br />RECEIVING/SALES NIGHT LIGHTS, SECURITY OUTLETS, OUTDOOR ICE <br />MERCHANDISER, AUTOMATIC DOORS, TELEPHONE BOARD, DOOR <br />BUZZER, OFFICE RECEPTACLES, OFFICE LIGHTS, BREAK ROOM, <br />RESTROOMS, EMERGENCY/EXIT LIGHTS AND AS SHOWN ON PANEL <br />LAYOUT. <br />7. FULLY LABEL ALL PANEL SCHEDULES ACCURATELY AND LEGIBLY. <br />HAND WRITTEN LABELS NOT ACCEPTABLE <br />&PROVIDE AND INSTALL CONDUIT FROM PANEL TO NEW BUILDING SIGN <br />LOCATION, TERMINATING IN A JUNCTION BOX TO BE CENTERED <br />HORIZONTALLY ON TENANT'S PROPOSED SPACE AND VERTICALLY ON <br />THE CANOPY. <br />NOT TO SCALE <br />9. PROVIDE AND INSTALL A TIMER AND PHOTOCELL COMBINATION PER <br />TENANT'S CRITERIA PLANS. ROUTE THE FOLLOWING CIRCUITS THROUGH <br />THE TIMER/PHOTECELL ASSEMBLY: <br />PYLON SIGN, BUILDING SIGN, PARKING LOT LIGHTS, WALL PACKS, AND <br />CANOPY LIGHTS <br />10. PROVIDE AND INSTALL 1" CONDUIT WITH PULL STRING ABOVE THE <br />MANAGER'S OFFICE WITH ROOF OR WALL PENETRATION FOR VSAT <br />(TENANT SATELLITE). COORDINATE EXACT LOCATION WITH TENANT <br />CONSTRUCTION DEPARTMENT PROJECT MANAGER. <br />11. PROVIDE AND INSTALL CONDUIT WITH PULL STRINGS AT MANAGER'S <br />OFFICE, CASH REGISTER AREA AND DMARC PANEL. COORDINATE <br />EXACT LOCATION WITH TENANT CONSTRUCTION DEPARTMENT <br />PROJECT MANAGER. <br />12. PROVIDE 1" CONDUIT FROM OFFICE TO CENTER OF SALES AREA <br />TERMINATING WITH A JUNCTION BOX. HOLD CONDUIT TIGHT TO <br />STRUCTURE. WAP MOUNTED AT 12'-0" AFF, <br />13. PROVIDE AND INSTALL CONDUIT FROM PANEL, THROUGH BUILDING, AND <br />UNDERGROUND TO PYLON SIGN LOCATION. STUB UP CONDUIT 12" ABOVE <br />GRADE AT PYLON LOCATION, CAP AND MARK WITH 36" HIGH STAKE. <br />14. LOW VOLTAGE VENDOR TO PROVIDE AND INSTALL 24 GA., 4 TWISTED -PAIR, <br />CATEGORY -FIVE (CAT5) DATA CABLE WITH MODULAR COMBO RJ-11/ RJ-45 <br />JACK AT MANAGER'S OFFICE. CABLE TO BE RUN FROM JACK TO DATA HUB <br />LOCATION WITH 6' LEFT COILED ABOVE CEILING FOR INSTALLATION TO DATA <br />HUB. AN RJ-45 MALE FITTING SHOULD BE CRIMPED ON THIS END. DOLLAR <br />GENERAL STORE OPENING TEAM WILL MAKE FINAL CONNECTION INTO THE <br />DATA H U B . <br />*NOTE: <br />PROVIDE 208V, 1 PHASE CONNECTION T A J-BOX AT <br />90" AFF WITH 3 #12 CU. & #12 GROUND IN 4"C. R.C. <br />TO PROVIDE AND INSTALL 30A/2NF DISCONNECT <br />SWITCH AND WIRE FROM DISCONNECT SWITCH TO <br />EQUIPMENT CONNECTIONS. <br />VERIFY FINAL LOCATION OF ALL ELECTRICAL <br />FIXTURE LAYOUT PLAN PROVIDED BY STORE <br />NT REQUIRES <br />L SPACE. <br />@ 7'-0" A.F.F. <br />WITH THE FINAL <br />PLANNING. <br />1 <br />2 <br />PROPO <br />SE <br />D <br />LOCATIO <br />N: <br />ZEPHYRHILLS <br />FL <br />5931 GALL <br />BLVD. <br />REVISED <br />BY: <br />Sim ---- <br />• <br />W <br />N <br />0 <br />z <br />W M <br />'` <br />W �o� <br />o <br />E <br />Q <br />W <br />z0 <br />0 <br />o <br />Iql- <br />J <br />> <br />�ij <br />U) <br />0c) <br />Q <br />O � <br />0 <br />DATE: <br />5/30/2018 <br />SCALE: <br />N.T.S. <br />SHEET NO: <br />El <br />