BUILDING SIGNS
<br />SIGN SIZE
<br />SIGN WT.
<br /># OF CKTS.
<br />AMPS
<br />VOLTS
<br />3'x23' BOX
<br />380 LBS.
<br />(1) 15 A
<br />2.5
<br />115
<br />3'-9"x26' BOX
<br />441 LBS.
<br />(1) 15 A
<br />5
<br />115
<br />4'-6"x33'-3" BOX
<br />750 LBS.
<br />(1) 15 A
<br />8.4
<br />115
<br />5'x40' BOX
<br />1220 LBS.
<br />(1) 15 A
<br />10
<br />115
<br />BUILDING LETTERS
<br />SIGN SIZE
<br />SIGN WT.
<br /># OF CKTS.
<br />AMPS
<br />VOLTS
<br />18"
<br />215 LBS.
<br />(2) 15 A
<br />19.6
<br />115
<br />24"
<br />288 LBS.
<br />(1) 15 A & (1) 20 A
<br />23.45
<br />115
<br />30"
<br />387 LBS.
<br />(2) 20 A
<br />28
<br />115
<br />36"
<br />649 LBS.
<br />(2) 15 A & (1) 20 A
<br />32.9
<br />115
<br />REQUIRED NATIONAL ACCOUNT VENDORS
<br />COMPANY
<br />NATIONAL CONTACT
<br />PHONE # / EMAIL
<br />BUILDING SIGNS, BUILDING LETTERS, PYLON SIGNS
<br />DUALITE SALES
<br />ROSE SHINKLE
<br />513-724-7100
<br />(AR, IA, IL, IN, KY, KS, LA, MI, MN, MO, MS, OH,
<br />& SERVICE
<br />(SR. PROJECT MANAGER)
<br />rshinkle@dualite.com
<br />OK, TN,TX,WI)
<br />SIGN RESOURCE
<br />IDENTITY GROUP
<br />ANGII HEIDBRINK
<br />323-485-4720
<br />(AZ, CA, CO, NE, NM,NV, SD, UT, WY)
<br />EVERBRITE
<br />CHRISTINE OLSON
<br />414-427-2329
<br />(AL, CT, DE, FL, GA, MA, MD, ME, NC, NH, NJ,
<br />NY, PA, RI, SC, VA, VT, WV)
<br />NATIONAL ACCOUNT & CONTACT INFORMATION SUBJECT TO CHANGE
<br />LINE #1 WILL HAVE TWO RJ-11 JACKS. ONE
<br />AT REGISTER, SECOND IN THE OFFICE. LABEL
<br />AS PHONE. ALL PHONE JACKS REQUIRE A
<br />BLUE SEPARATE 24 ga. CAT 5,4 PAIR HOME RUN TO
<br />& DMARC. NOTE SEPARATE GROUND WIRES. REFER
<br />BLUE/WHITE TO SHEET E-3 FOR DETAILS.
<br />BUZZER - TORK MODEL #TA725 W/TRANSFORMER MODEL
<br />#TA592.
<br />COMMERCIAL GRADE PUSH BUTTON
<br />(p
<br />125V NEMA 5-20R DUPLEX
<br />(p
<br />125/250V NEMA L14-20-R 4 PRONG TWIST LOCK
<br />125V NEMA 5-20R QUAD
<br />'-❑
<br />DISCONNECT
<br />I
<br />POWER POLE -BLACK MAGIC
<br />v
<br />PHONE JACK @REGISTER
<br />O
<br />VOICE/DATA PORT = RJ-111 RJ-45 DATA JACK, PHONE
<br />COMBO @OFFICE
<br />$nn
<br />PROVIDE OCCUPANCY LIGHT SENSOR - LEVITON ODS 10-IDW
<br />20 AMP TOGGLE SWITCH
<br />NL
<br />NIGHT LIGHT CIRCUIT
<br />ELECTRICAL SPECIFICATIONS:
<br />ALL EXPOSED WIRING SHALL BE CONTAINED IN CONDUIT OF PROPER SIZE.
<br />2. ALL WIRING SHALL CONFORM TO LOCAL, STATE, AND FEDERAL CODES.
<br />3. ELECTRICAL SERVICE TO BE MINIMUM 400 AMP, 3-PHASE (PREFERRED) OR 600 AMP,
<br />SINGLE PHASE OR LARGER IF REQUIRED BY CODE OR ELECTRICAL LOAD.
<br />4. REGISTER POWER POLES - VERIFY REGISTER CONFIGURATION ON FINAL FIXTURE PLAN
<br />BEFORE ORDERING AND INSTALLATION OF ELECTRICAL COMPONENTS. CUSTOM BUILT
<br />POWER POLE ASSEMBLY AVAILABLE FROM D&P CUSTOM LIGHTS & PRODUCTS INC.
<br />PHONE # (800) 251-2200 OR (615) 350-7800, 7111 COCKRILL BEND INDUSTRIAL ROAD.
<br />NASHVILLE, TN 37209
<br />EXTERIOR EXPOSED PHONE LINES TO BE INSTALLED IN RIGID CONDUIT. PROVIDE
<br />EMERSON 3/4" x 5-FT. METALLIC CABLE U-GUARD #755 OR EQUAL.
<br />6. ELECTRIC PANELS TO BE LABELED CORRECTLY WITH LEGIBLE PRINT.
<br />7. LOW VOLTAGE VENDOR TO PROVIDE AND INSTALL ONE (1) 24 GA., 4 TWISTED -PAIR,
<br />CATEGORY -FIVE (CAT5) DATA CABLE WITH MODULAR COMBO RJ-11/RJ/45 JACK AT
<br />MANAGER'S OFFICE. CABLE TO BE RUN FROM JACK TO DATA HUB LOCATION WITH 6'-0"
<br />LEFT COILED FOR INSTALLATION TO DATA HUB. A RJ-45 MALE FITTING SHOULD BE
<br />CRIMPED ON THIS END. DOLLAR GENERAL STORE OPENING TEAM WILL MAKE FINAL
<br />CONNECTION INTO THE DATA HUB.
<br />8. SEE SHEET F1 FOR COOLER/FREEZER OPTIONS. VERIFY FINAL LOCATION AND NW
<br />OF COOLERS AND FREEZERS ON FINAL FIXTURE PLAN BEFORE ORDERING AND
<br />INSTALLATION OF ELECTRICAL COMPONENTS. EACH COOLER REQUIRES A 20 AMP
<br />DEDICATED GROUND CIRCUIT TO BE USED FOR A 110v OUTLET. EACH OF THESE U
<br />DRAW 12 AMPS. EACH FREEZER REQUIRES ONE - 125/250V OUTLET NEMA #L14-20
<br />PRONG TWIST LOCK. EACH UNIT DRAWS 16 AMPS. TWO DOOR FREEZER IN RECEI
<br />AREA REQUIRES ONE 125/250V NEMA 14-20R OUTLET ON A 20 AMP DEDICATED CIR
<br />UNIT DRAWS 8 AMPS.
<br />PYLON SIGNS
<br />SIGN SIZE
<br />SIGN WT.
<br /># OF CKTS.
<br />AMPS
<br />VOLTS
<br />4'x8'
<br />188 LBS.
<br />(1) 15 A
<br />1.7
<br />115
<br />5'x10'
<br />375 LBS.
<br />(1) 15 A
<br />3.4
<br />115
<br />6'x16'
<br />738 LBS.
<br />(1) 15 A
<br />5
<br />115
<br />NOTES:
<br />1. PROVIDE AND INSTALL CONDUIT, JUNCTION BOXES, D&P CONNECTORS
<br />AND/OR POWER POLE(S) FOR CASH REGISTER(S) PER TENANT'S
<br />CRITERIA PLANS, VERIFY LOCATION OF JUNCTION BOXES WITH
<br />TENANT'S FIXTURE FLOOR PLAN PROVIDED BEFORE TURNOVER DATE.
<br />2. PROVIDE AND INSTALL POWER POLE(S) FOR REGISTERS AND ICE CREAM
<br />FREEZER PER TENANT'S CRITERIA PLANS.
<br />3. PROVIDE AND INSTALL POWER POLES FOR REFRIGERATION UNITS PER
<br />TENANT'S CRITERIA PLANS.
<br />4. VERIFY LOCATION OF POWER POLES WITH TENANT'S FIXTURE FLOOR
<br />PLAN PROVIDED BEFORE TURNOVER DATE.
<br />5. PROVIDE AND INSTALL ELECTRICAL RECEPTACLES PER TENANT'S
<br />CRITERIA PLANS.
<br />6. PROVIDE AND INSTALL BREAKER LOCKS ON THE FOLLOWING:
<br />REGISTER POWER POLES, SALES FLOOR COOLERS AND FREEZERS,
<br />RECEIVING/SALES NIGHT LIGHTS, SECURITY OUTLETS, OUTDOOR ICE
<br />MERCHANDISER, AUTOMATIC DOORS, TELEPHONE BOARD, DOOR
<br />BUZZER, OFFICE RECEPTACLES, OFFICE LIGHTS, BREAK ROOM,
<br />RESTROOMS, EMERGENCY/EXIT LIGHTS AND AS SHOWN ON PANEL
<br />LAYOUT.
<br />7. FULLY LABEL ALL PANEL SCHEDULES ACCURATELY AND LEGIBLY.
<br />HAND WRITTEN LABELS NOT ACCEPTABLE
<br />&PROVIDE AND INSTALL CONDUIT FROM PANEL TO NEW BUILDING SIGN
<br />LOCATION, TERMINATING IN A JUNCTION BOX TO BE CENTERED
<br />HORIZONTALLY ON TENANT'S PROPOSED SPACE AND VERTICALLY ON
<br />THE CANOPY.
<br />NOT TO SCALE
<br />9. PROVIDE AND INSTALL A TIMER AND PHOTOCELL COMBINATION PER
<br />TENANT'S CRITERIA PLANS. ROUTE THE FOLLOWING CIRCUITS THROUGH
<br />THE TIMER/PHOTECELL ASSEMBLY:
<br />PYLON SIGN, BUILDING SIGN, PARKING LOT LIGHTS, WALL PACKS, AND
<br />CANOPY LIGHTS
<br />10. PROVIDE AND INSTALL 1" CONDUIT WITH PULL STRING ABOVE THE
<br />MANAGER'S OFFICE WITH ROOF OR WALL PENETRATION FOR VSAT
<br />(TENANT SATELLITE). COORDINATE EXACT LOCATION WITH TENANT
<br />CONSTRUCTION DEPARTMENT PROJECT MANAGER.
<br />11. PROVIDE AND INSTALL CONDUIT WITH PULL STRINGS AT MANAGER'S
<br />OFFICE, CASH REGISTER AREA AND DMARC PANEL. COORDINATE
<br />EXACT LOCATION WITH TENANT CONSTRUCTION DEPARTMENT
<br />PROJECT MANAGER.
<br />12. PROVIDE 1" CONDUIT FROM OFFICE TO CENTER OF SALES AREA
<br />TERMINATING WITH A JUNCTION BOX. HOLD CONDUIT TIGHT TO
<br />STRUCTURE. WAP MOUNTED AT 12'-0" AFF,
<br />13. PROVIDE AND INSTALL CONDUIT FROM PANEL, THROUGH BUILDING, AND
<br />UNDERGROUND TO PYLON SIGN LOCATION. STUB UP CONDUIT 12" ABOVE
<br />GRADE AT PYLON LOCATION, CAP AND MARK WITH 36" HIGH STAKE.
<br />14. LOW VOLTAGE VENDOR TO PROVIDE AND INSTALL 24 GA., 4 TWISTED -PAIR,
<br />CATEGORY -FIVE (CAT5) DATA CABLE WITH MODULAR COMBO RJ-11/ RJ-45
<br />JACK AT MANAGER'S OFFICE. CABLE TO BE RUN FROM JACK TO DATA HUB
<br />LOCATION WITH 6' LEFT COILED ABOVE CEILING FOR INSTALLATION TO DATA
<br />HUB. AN RJ-45 MALE FITTING SHOULD BE CRIMPED ON THIS END. DOLLAR
<br />GENERAL STORE OPENING TEAM WILL MAKE FINAL CONNECTION INTO THE
<br />DATA H U B .
<br />*NOTE:
<br />PROVIDE 208V, 1 PHASE CONNECTION T A J-BOX AT
<br />90" AFF WITH 3 #12 CU. & #12 GROUND IN 4"C. R.C.
<br />TO PROVIDE AND INSTALL 30A/2NF DISCONNECT
<br />SWITCH AND WIRE FROM DISCONNECT SWITCH TO
<br />EQUIPMENT CONNECTIONS.
<br />VERIFY FINAL LOCATION OF ALL ELECTRICAL
<br />FIXTURE LAYOUT PLAN PROVIDED BY STORE
<br />NT REQUIRES
<br />L SPACE.
<br />@ 7'-0" A.F.F.
<br />WITH THE FINAL
<br />PLANNING.
<br />1
<br />2
<br />PROPO
<br />SE
<br />D
<br />LOCATIO
<br />N:
<br />ZEPHYRHILLS
<br />FL
<br />5931 GALL
<br />BLVD.
<br />REVISED
<br />BY:
<br />Sim ----
<br />•
<br />W
<br />N
<br />0
<br />z
<br />W M
<br />'`
<br />W �o�
<br />o
<br />E
<br />Q
<br />W
<br />z0
<br />0
<br />o
<br />Iql-
<br />J
<br />>
<br />�ij
<br />U)
<br />0c)
<br />Q
<br />O �
<br />0
<br />DATE:
<br />5/30/2018
<br />SCALE:
<br />N.T.S.
<br />SHEET NO:
<br />El
<br />
|