Laserfiche WebLink
K <br />ELECTRICAL LEGEND <br />F21 O <br />FLUORESCENT TROFFER, TYPE AS NOTED <br />DUPLEX RECEPTACLE <br />18" AFF OR AS NOTED, NEMA 5-20R <br />LAFLUORESCENT <br />TROFFER, TYPE AS NOTED <br />PROVIDE WITH EMERGENCY BALLAST <br />wP <br />WEATHER PROOF DUPLEX RECEPTACLE <br />18" AFF OR AS NOTED, NEMA 5-20R <br />® <br />FLUORESCENT TROFFER, TYPE AS NOTED <br />DUPLEX RECEPTACLE <br />ABOVE COUNTER OR AS NOTED, NEMA 5-20R <br />® <br />FLUORESCENT TROFFER, TYPE AS NOTED <br />PROVIDE WITH EMERGENCY BALLAST <br />QUAD RECEPTACLE <br />18" AFF OR AS NOTED, NEMA 5-20R <br />Q <br />RECESSED CAN FIXTURE, TYPE AS NOTED <br />IG <br />DUPLEX RECEPTACLE <br />18" AFF OR AS NOTED, NEMA 5-20R <br />O <br />RECESSED CAN FIXTURE, TYPE AS NOTED <br />PROVIDE WITH EMERGENCY BALLAST <br />SPECIAL PURPOSE RECEPTACLE <br />18" AFF OR AS NOTED, SEE SCHEDULE <br />F--o---i <br />FLUORESCENT STRIP FIXTURE <br />WALL / CEILING MOUNTED JUNCTION BOX <br />(Di <br />WALL MOUNTED FIXTURE, TYPE AS NOTED <br />60/3/1 <br />0i <br />UNFUSED DISCONNECT SWITCH <br />RATING/POLES/NEMA RATING <br />PENDANT FIXTURE, TYPE AS NOTED <br />60/3/3R/40 <br />FUSED DISCONNECT SWITCH <br />RATING/POLES/NEMA RATING/FUSE SIZE <br />PENDANT FIXTURE, TYPE AS NOTED <br />PROVIDE WITH EMERGENCY BALLAST <br />MOTOR <br />44+ <br />TRACK LIGHT FIXTURE, TYPE AS NOTED <br />—I�� <br />GROUND <br />IN <br />EMERGENCY LIGHT <br />TRANSFORMER <br />41 <br />EXIT/EMERGENCY LIGHT COMBINATION <br />OM <br />UTILITY GRADE METER <br />® <br />CEILING MOUNTED EXIT SIGN <br />® <br />TRANSIENT VOLTAGE SURGE SUPPRESSOR <br />WALL MOUNTED EXIT SIGN <br />v <br />TELEPHONE OUTLET, PROVIDE 4" BOX <br />SINGLE GANG PLASTER RING, 3/4" C ABOVE CEILING <br />$ <br />SINGLE POLE SWITCH, 44" AFF <br />V <br />DATA OUTLET, PROVIDE 4" BOX <br />SINGLE GANG PLASTER RING, 3/4" C ABOVE CEILING <br />TWO SINGLE POLE SWITCHES GANGED TOGETHER <br />FOR INNER/OUTER CONTROL OF LAMPS, 44" AFFsm <br />© <br />TELEVISION/CABLE OUTLET <br />THREE SINGLE POLE SWITCHES GANGED TOGETHER <br />44" AFF <br />® <br />TELEPHONE OUTLET, PROVIDE 4" BOX <br />FLUSH IN FLOOR, 3/4" C ABOVE CEILING <br />$3 <br />THREE WAY SWITCH, 44" AFF <br />® <br />DATA OUTLET, PROVIDE 4" BOX FLUSH IN FLOOR, 3/4" C ABOVE CEILING <br />03 <br />TWO THREE WAY SWITCHES GANGED TOGETHER <br />FOR INNER/OUTER CONTROL OF LAMPS, 44" AFF <br />DOOR HOLD -OPEN DEVICE <br />$4 <br />FOUR WAY SWITCH, 44" AFF <br />a <br />TRANSFORMER, SEE ONE LINE <br />WALL BOX DIMMER 1000W UNLESS NOTED DIFFERENTLY <br />44" AFF <br />SPEAKER STROBE <br />$Wp <br />WEATHER PROOF SWITCH, 44" AFF <br />HORN <br />$M <br />MOTOR RATED SWITCH, 44" AFF OR AS NOTED <br />Q <br />PULL STATION <br />$pg <br />COMBINATION SWITCH AND OCCUPANCY SENSOR, 44" AFF <br />Q <br />FIRE ALARM STROBE, MIN 75 CANDELA <br />CEILING / WALL MOUNT <br />$T <br />DIGITAL TIMER SWITCH, 44" AFF <br />am <br />DUCT MOUNTED SMOKE DETECTOR <br />Q <br />CEILING MOUNTED OCCUPANCY SENSOR <br />OS <br />SMOKE DETECTOR <br />t <br />WALL MOUNTED OCCUPANCY SENSOR, 44" AFF <br />OH <br />HEAT DETECTOR <br />® <br />TIME CLOCK <br />OS <br />TAMPER SWITCH <br />LC <br />LIGHTING CONTACTOR <br />FS <br />FLOW SWITCH <br />® <br />PHOTO CELL <br />RACEWAY CONCEALED IN WALL OR ABOVE CEILING <br />® <br />8" CONE SPEAKER IN CEILING <br />EC TO PROVIDE BLACK SPEAKER <br />RACEWAY EXPOSED <br />8" CONE SPEAKER IN WALL <br />EC TO PROVIDE BLACK SPEAKER <br />RACEWAY CONCEALED IN FLOOR SLAB, BELOW SLAB OR GRADE <br />BELOW SLAB OR GRADE, OR UNDER RAISED ACCESS FLOOR <br />VOLUME CONTROL <br />-0 <br />DENOTES CONDUIT TURNING UP IN PLAN VIEW <br />PLYWOOD EQUIPMENT BACKBOARD <br />4'X8' UNLESS NOTED OTHERWISE <br />-3 <br />DENOTES CONDUIT TURNING DOWN IN PLAN VIEW <br />®4 <br />CLOSED CIRCUIT TELEVISION CAMERA <br />- 3 <br />STUB UP <br />COAXIAL CABLE OUTLET <br />XXXX <br />SHORT CIRCUIT AVAILABLE CURRENT <br />(NOTE: ALL SYMBOLS SHOWN MAY NOT APPEAR ON DRAWINGS AND ARE USED AS APPLICABLE TO THIS PROJECT) <br />ABBREVIATIONS <br />ELECTRICAL SPECIFICATIONS <br />A. DEFINITIONS <br />1. 'PR❑VIDE't FURNISH AND INSTALL, COMPLETE AND READY FOR ❑PERATI❑N, <br />2. 'INSTALL'i RECEIVE, MOUNT, AND CONNECT, COMPLETE AND READY FOR ❑PERATI❑N. <br />3. 'FURNISH'i SUPPLY, DELIVER TO JOB SITE, PROTECT AND STORE. <br />B. WORK INCLUDEDi PR❑VIDE ALL LABOR, TOOLS, MATERIAL, EXCAVATION, BACKFILL, CUTTING, <br />PATCHING, TESTING, ADJUSTING, AND TRADE C❑ORDINATION REQUIRED FOR A COMPLETE AND <br />FULLY ❑PERATI❑NAL INSTALLATION, AS DESCRIBED ON THE DRAWINGS OR IN THE <br />SPECIFICATIONS, <br />C. CODES, RULES, AND REGULATIONS, COMPLY WITH ALL CODES ENFORCED BY THE LOCAL <br />INSPECTION AUTH❑RITY, THE EDITION OF THE NATI❑NAL ELECTRICAL CODE BEING ENFORCED FOR <br />THIS PROJECT BY THE LOCAL INSPECTION AUTH❑RITY, ALL APPLICABLE LAWS AND ORDINANCE, <br />NFPA FIRE CODES, STANDARD BUILDING CODE. GIVE ALL NECESSARY NOTICES, OBTAIN ALL <br />REQUIRED PERMITS, AND PAY ALL INSPECTION AND OTHER FEES REQUIRED BY AUTHORITIES <br />HAVING JURISDICTION OVER THE WORK. <br />D. MATERIALS ALL MATERIAL SHALL BE NEW, AND SHALL COMPLY WITH THE INDICATED STANDARDS, <br />ALL MATERIAL SHALL BE UL LABELED OR UL LISTED, ALL MATERIAL SHALL BE OF A SUITABLE <br />TYPE AND RATING FOR THE INTENDED USE, AND SHALL BE INSTALLED IN CONFORMANCE WITH <br />THE INSTRUCTIONS AND RECOMMENDATIONS OF THE MANUFACTURER, <br />E. DRAWINGS <br />1. THE DRAWINGS ARE SCHEMATIC IN NATURE AND DO NOT SHOW ALL OF THE REQUIRED <br />DETAILS OF THE WORK, ALL MATERIALS CUSTOMARILY CONSIDERED TO BE A PART OF THE <br />ELECTRICAL WORK AND REQUIRED FOR A COMPLETE AND OPERATIONAL INSTALLATION SHALL <br />BE PROVIDED WITH❑UT ADDITIONAL COST TO THE OWNER. <br />2. THE CONTRACTOR SHALL REFER ALSO TO THE ARCHITECTURAL DRAWINGS AND TO THE <br />DRAWINGS OF ALL OTHER TRADES TO COORDINATE THE ELECTRICAL INSTALLATION, WHERE <br />ELECTRICAL EQUIPMENT IS SHOWN ON ARCHITECTURAL DRAWINGS OR DETAILS, THE <br />EQUIPMENT SHALL BE INSTALLED AS SHOWN ON THE ARCHITECTURAL DRAWINGS. <br />3. EQUIPMENT OF OTHER TRADES IS SHOWN SCHEMATICALLY ON THE ELECTRICAL DRAWINGS, <br />THE CONTRACTOR SHALL EXAMINE THE DRAWINGS OF THE TRADE PROVIDING THE EQUIPMENT <br />BEFORE ROUGHING IN THE CONNECTIONS FOR IT, THE CONTRACTOR SHALL CONNECT THE <br />EQUIPMENT WHERE ACTUALLY INSTALLED, INCLUDING WIRING THROUGH ANY LINE VOLTAGE <br />CONTROLLERS, WITHOUT ANY ADDITI❑NAL COST TO THE OWNER. <br />4. PRIOR TO ROUGHING IN CIRCUITS FOR EQUIPMENT FURNISHED BY OTHER TRADES, AND PRIOR <br />TO RELEASING FOR MANUFACTURE PANELBOARDS, STARTERS OR MOTOR CONTROL CENTERS <br />FEEDING SUCH EQUIPMENT, THE CONTRACTOR SHALL C❑❑RDINATE THE ELECTRICAL <br />PROVISIONS BEING PLANNED WITH THE TRADE PROVIDING THE EQUIPMENT AND SUBMIT ANY <br />CONFLICTS IN WRITING TO THE ARCHITECT, <br />5. THE ARCHITECT MAY DIRECT THE REL❑CATION OF ANY ELECTRICAL OUTLET, FIXTURE, OR <br />OTHER EQUIPMENT TO A L❑CATI❑N WITHIN 10 FEET OF THE LOCATION SHOWN ON THE <br />DRAWINGS AT NO ADDITIONAL COST TO THE OWNER PROVIDED SUCH RELOCATION IS <br />DIRECTED PRIOR TO THE INSTALLATION OF THE OUTLET, FIXTURE OR EQUIPMENT BEING <br />RELOCATED, <br />D. SUBMITTAL D❑CUMENTSi PRODUCT DATA AND SHOP DRAWINGS SHALL BE SUBMITTED IN SIX C❑PIES <br />TO THE ARCHITECT FOR REVIEW PRIOR TO THE RELEASE OF THE MATERIAL FOR MANUFACTURE, <br />REVIEW OF SUBMITTALS BY THE ARCHITECT WILL BE ONLY FOR GENERAL CONFORMANCE WITH <br />THE DRAWINGS AND SPECIFICATIONS. REVIEW WILL BE MADE ONLY OF INFORMATION CLEARLY <br />AND SPECIFICALLY INDICATED IN THE SUBMITTAL, AND DOES NOT IMPLY THE ACCEPTABILITY OF <br />DETAILS WHICH ARE NOT S❑ DESCRIBED IN THE SUBMITTAL. REVIEW OF THE SUBMITTAL <br />DOCUMENTS BY THE ARCHITECT DOES NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY TO <br />COMPLY WITH ALL REQUIREMENTS OF THE DRAWINGS AND SPECIFICATIONS. SUBMITTAL IS <br />REQUIRED FOR PANELBOARDS AND L❑ADCENTERS, LIGHT FIXTURES, WIRING DEVICES, FIRE ALARM <br />DEVICES, AND SURFACE ALUMINUM RACEWAY. <br />G. AS -BUILT DRAWINGS AS -BUILT DRAWINGS SHALL BE MAINTAINED AT THE J❑BSITE, AND SHALL <br />BE AVAILABLE FOR REVIEW DURING CONSTRUCTION. AS -BUILT DRAWINGS SHALL BE KEPT <br />CURRENT DURING THE CURSE OF CONSTRUCTION OF THE WORK. SUBMIT AS -BUILT DRAWINGS TO <br />THE ARCHITECT AT THE COMPLETION OF THE PROJECT. <br />H. TESTINGi TEST ALL PARTS OF THE WORK TO VERIFY COMPLIANCE WITH THE DRAWINGS AND <br />SPECIFICATIONS, VERIFY TIGHTNESS OF ALL MECHANICAL AND ELECTRICAL CONNECTIONS. VERIFY <br />INTEGRITY OF ALL WIRING SYSTEMS TO ASSURE CONTINUITY, ABSENCE OF UNINTENTI❑NAL <br />GROUNDS, AND INTEGRITY OF REQUIRED GROUNDS. <br />I. CHANGE REQUEST (CHANGE ORDER) APPROVAL, CHANGE REQUESTS WILL NOT BE CONSIDERED <br />UNLESS THE CONTRACTOR'S DETAILED LABOR AND MATERIAL ESTIMATE DESCRIBING THE CHANGE <br />IS SUBMITTED TO THE ARCHITECT ALONG WITH THE CHANGE REQUEST, WITH MATERIAL PRICES <br />AND LABOR UNITS ASSIGNED TO EACH LINE ITEM OF THE ESTIMATE. MATERIAL PRICES SHALL BE <br />THE ACTUAL PRICE PAID BY THE CONTRACTOR FOR MATERIAL PURCHASED OR THE ACTUAL PRICE <br />QUOTED TO THE CONTRACTOR BY THE MATERIAL VENDOR PROPOSED BY THE CONTRACTOR. <br />J. COORDINATION WITH THE WORK OF OTHERS COORDINATE WITH EACH TRADE FURNISHING <br />EQUIPMENT REQUIRING ELECTRICAL SERVICE TO INSURE THAT THE CHARACTERISTICS SHOWN ON <br />THE DRAWINGS FOR THE CIRCUIT SERVING THE EQUIPMENT ARE COMPATIBLE WITH THE <br />REQUIREMENTS OF THE EQUIPMENT BEING FURNISHED, CIRCUIT BREAKERS, FUSES, DISC❑NNECT <br />SWITCHES AND ASSOCIATED BRANCH CIRCUITS SHOWN ON THE DRAWINGS TO FEED HVAC <br />EQUIPMENT, KITCHEN EQUIPMENT, ELEVATOR MOTORS, AND OTHER EQUIPMENT HAVE BEEN <br />SELECTED BASED UPON THE CHARACTERISTICS OF EQUIPMENT BY ONE MANUFACTURER AND MAY <br />NOT BE CORRECT FOR THE EQUIPMENT BEING PR❑VIDED BY THE CONTRACTOR, THE CONTRACTOR <br />SHALL DETERMINE THE OPERATING CHARACTERISTICS OF THE EQUIPMENT ACTUALLY BEING <br />PROVIDED AND SHALL PR❑VIDE AT NO ADDITI❑NAL COST TO THE OWNER CIRCUIT BREAKERS, <br />FUSES, DISCONNECT SWITCHES AND BRANCH CIRCUITS AS REQUIRED BY THAT EQUIPMENT, <br />K. EXISTING WORK, THE EXISTING ELECTRICAL INSTALLATION SHALL REMAIN AS -IS AND IN <br />OPERATION EXCEPT WHERE OTHERWISE REQUIRED, GIVE WRITTEN NOTICE OF ANY UNFORESEEN <br />EXISTING CONDITIONS WHICH MAY AFFECT THE WORK, WORK INVOLVING EXISTING SYSTEMS OR <br />EXISTING SPACES SHALL BE ACCOMPLISHED WITH MINIMUM INCONVENIENCE TO THE OWNER, AND <br />SHALL BE DONE IN A MANNER AND TIME APPROVED BY THE OWNER, ANY INTERRUPTIONS SHALL <br />BE DURING TIMES DESIGNATED BY THE OWNER. <br />A, AMPS <br />AMPERES <br />FLA <br />FULL LOAD AMPERES <br />NO <br />NORMALLY OPEN, <br />A/C <br />AIR CONDITIONER <br />GND <br />GROUND <br />NUMBER L. <br />DEM❑LITIONi IN THE AREA SHOWN ON THE ARCHITECTURAL DRAWINGS TO BE DEMOLISHED REMOVE <br />AC <br />ALTERNATING CURRENT <br />GALV <br />GALVANIZED <br />NTS <br />NOT TO SCALE <br />ALL EXISTING CONDUITS, CONDUCTORS, BOXES, FIXTURES, SERVICE ENTRANCE CONDUCTORS, <br />AF <br />AMPERE FRAME <br />GRS <br />GALVANIZED RIGID STEEL <br />PNL <br />PANELBOARD <br />DISTRIBUTION EQUIPMENT, AND ALL OTHER ELECTRICAL EQUIPMENT NOT SHOWN TO REMAIN. <br />AFF <br />ABOVE FINISHED FLOOR <br />GFCI <br />GROUND FAULT <br />PVC <br />POLYVINYL CHLORIDE <br />UNLESS OTHERWISE INDICATED, MATERIAL BEING REMOVED INCLUDING WIRE, C❑NDUIT, AND <br />AFG <br />ABOVE FINISHED GRADE <br />CIRCUIT INTERRUPTER <br />RGS <br />RIGID GALVANIZED <br />HANGING MATERIALS BEING REMOVED SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND <br />AIC <br />AMPERE <br />STEEL CONDUIT <br />SHALL BE REMOVED FROM THE PREMISES. EQUIPMENT NOTED TO REMAIN THE PROPERTY OF THE <br />INTERRUPTING CURRENT <br />GFI <br />GROUND FAULT INTERRUPTER <br />RMC <br />RIGID METALLIC <br />OWNER SHALL BE STORED ON SITE AS DIRECTED BY THE ARCHITECT, CO❑RDINATE WITH OTHER <br />AL <br />ALUMINUM <br />HD <br />HEAT DETECTOR <br />CONDUIT (GALVANIZED) <br />TRADES AND DISC❑NNECT MOTORS, HEATERS, OR OTHER EQUIPMENT AS REQUIRED FOR THE <br />ANSI <br />AMERICAN NATIONAL <br />HP <br />HORSEPOWER <br />RMS <br />ROOT -MEAN -SQUARE <br />DEMOLITION OF OTHER TRADES WORK. CUT OFF ALL IN FLOOR CONDUITS, GRIND SMOOTH WITH <br />STANDARDS INSTITUTE <br />IMC <br />INTERMEDIATE METAL CONDUIT <br />RNC <br />RIGID NON-METALLIC <br />FLOOR AND PREPARE FOR PATCHING BY OTHERS, REMOVE CONDUCTORS AND DEVICES FROM WALL <br />ISC <br />INTERRUPTING SHORT CIRCUIT <br />CONDUIT <br />AND CEILING OUTLETS AND PREPARE OUTLET FOR PATCHING BY OTHERS, CONTRACTOR SHALL <br />AWG <br />AMERICAN WIRE GAUGE <br />IG <br />ISOLATED GROUND <br />SCA <br />SHORT CIRCUIT <br />DENOTE ALL DEMOLISHED CIRCUITS ON EXISTING PANEL DIRECTORIES AND NOTE ALL SPARE <br />BC <br />BKBD <br />BARE COPPER <br />BACKBOARD <br />INST <br />INSTANTANEOUS <br />AVAILABLE <br />BREAKERS, <br />JB <br />JUNCTION BOX <br />SWBD <br />SWITCHBOARD <br />C <br />CONDUIT <br />KAIC <br />KILO (THOUSAND) AMPERES <br />SWGR <br />SWITCHGEAR M. <br />BASIC MATERIALS AND METHODSi <br />CB <br />CKT <br />CIRCUIT BREAKER <br />CIRCUIT <br />INTERRUPTING CAPACITY <br />TBD <br />TO BE DETERMINED <br />1. ALL WORK SHALL BE SUPPORTED FROM STRUCTURAL ELEMENTS OF THE BUILDING, EXCEPT <br />CU <br />COPPER <br />KCMIL <br />KILO (THOUSAND) <br />TCP <br />TEMPERATURE CONTROL <br />CEILING MOUNTED EQUIPMENT SUCH AS LIGHT FIXTURES, DETECTORS, REMOTE LAMPS, ETC, <br />DIST <br />DISTRIBUTION <br />CIRCULAR MILS <br />PANEL <br />CEILING MOUNTED EQUIPMENT SHALL BE SUPPORTED FROM CEILING STRUCTURAL MEMBERS, <br />DN <br />DOWN <br />KV <br />KILO (THOUSAND) VOLTS <br />TD <br />TIME DELAY <br />INDEPENDENT OF CEILING TILES, SIZE AND SPACING OF SUPPORTS SHALL BE DETERMINED <br />DP <br />DISTRIBUTION PANEL <br />KVA <br />KILO (THOUSAND) <br />TEL <br />TELEPHONE <br />BY THE LOAD TO BE SUPPORTED SUCH THAT THE WORKING LOAD OF SUPPORTS WILL NOT <br />DWG <br />DRAWING <br />VOLT-AMPERES <br />TVSS <br />TRANSIENT VOLTAGE <br />EXCEED A SAFETY FACTOR OF 411, PLASTIC ANCHORS ARE NOT ACCEPTABLE, ELECTRICAL <br />EB <br />ENCASED BURIAL <br />KW <br />KILO (THOUSAND) WATTS <br />SURGE SUPPRESSION <br />WORK SHALL NOT BE SUPPORTED FROM PIPING, DUCTS, OR WORK OF OTHER TRADES, <br />KWH <br />KILO (THOUSAND) WATT-HOURS <br />TYP <br />TYPICAL <br />EC <br />EMPTY CONDUIT <br />LFMC <br />LIQUID -TIGHT FLEXIBLE <br />UG <br />UNDERGROUND <br />2. PROVIDE ENGRAVED PLASTIC NAMEPLATES FOR ALL SWITCHB❑ARDS, PANELBOARDS, MOTOR <br />EEW <br />ENERGIZED ELECTRICAL WORK <br />METAL CONDUIT <br />UL <br />UNDERWRITER'S LABORATORIES <br />CONTROL CENTERS, STARTERS, DISCONNECTS, PRIMARY SELECTOR SWITCHES, AND <br />EGC <br />EQUIPMENT GROUNDING <br />MCB <br />MAIN CIRCUIT BREAKER <br />UON <br />UNLESS OTHERWISE <br />TRANSFORMERS. INDICATE EQUIPMENT NAME, CIRCUIT SOURCE AND NUMBER, CIRCUIT SIZE, <br />CONDUCTOR <br />MCM <br />THOUSAND CIRCULAR MILS <br />UNDERGROUND PULLBOX <br />AMPERE RATING, VOLTAGE AND PHASE. NAMEPLATES SHALL BE BLACK BACKGROUND <br />ELR <br />END -OF -LINE RESISTOR <br />MCCB <br />MOLDED CASE <br />V <br />VOLTS <br />LAMA(❑ID PLASTIC WITH 0,25' WHITE LETTERS, <br />EWC <br />ELECTRIC WATER COOLER <br />MLO <br />MAIN LUGS ONLY <br />VA <br />VOLT-AMPERES <br /><E> <br />EXISTING <br />N <br />NEUTRAL <br /><ER> <br />EXISTING TO REMAIN <br />NEC <br />NATIONAL ELECTRICAL <br />VFD <br />VARIABLE <br /><EX> <br />EXISTING <br />CODE <br />FREQUENCY DRIVE <br />FA <br />FIRE ALARM <br />NESC <br />NATIONAL ELECTRICAL <br />WH <br />WATER HEATER <br />FAA <br />FIRE ALARM ANNUNCIATOR <br />SAFETY CODE <br />WP <br />WEATHERPROOF <br />FACP <br />FIRE ALARM CONTROL PANEL <br />NIC <br />NOT IN CONTRACT <br />WT <br />WATERTIGHT <br />NL <br />NIGHT LIGHT <br />XFMR <br />TRANSFORMER <br />3. ALL PENETRATI❑NS OF FIRE RATED WALLS, SLABS, PARTITI❑NS, AND CEILINGS SHALL BE <br />FIREPR❑OFED WITH A U.L. LISTED SYSTEM THAT WILL MAINTAIN THE ORIGINAL FIRE RATING <br />OF THE PENETRATED STRUCTURE. ALL FIREPR❑❑FING MATERIALS APPLIED AT ANY ONE <br />PENETRATION SHALL BE THE PRODUCT OF ONE MANUFACTURER AND SHALL BE APPLIED AS <br />DESCRIBED BY THE UL FIREPR❑❑FING SYSTEM BEING CONSTRUCTED. FIREPROOFING OF <br />SLEEVES, CABLE TRAYS, TROUGHS, AND NIPPLES TO BE USED FOR LOW VOLTAGE CABLES <br />SHALL BE INDEFINITELY NON -HARDENING AND REMOVABLE WITH COMMON HAND TOOLS. <br />4. BACKBOARDS SHALL BE 8 FT, HIGH BY LENGTH SHOWN ON THE DRAWINGS AND SHALL BE <br />UL LABELED FIRE TREATED PLYWOOD. <br />5, PROVIDE ALL POWER WIRING AND CONNECTIONS FOR ALL ELECTRICALLY OPERATED <br />EQUIPMENT. POWER WIRING INCLUDES WIRING THROUGH ANY LINE VOLTAGE CONTROL <br />DEVICES, SUCH AS THERMOSTATS AND MANUAL STARTERS, INSTALL ALL STARTERS AND <br />CONTACTORS EXCEPT THOSE FURNISHED AS AN INTEGRAL PART OF THE EQUIPMENT, <br />6. CONNECTIONS TO MOTORS, TRANSFORMERS, AND OTHER VIBRATING EQUIPMENT NOT <br />INSTALLED IN A PLENUM SPACE SHALL BE MADE WITH A SHORT LENGTH OF LIQUIDTIGHT <br />FLEXIBLE C❑NDUIT, MINIMUM 18', INSTALLED IN A MANNER TO PERMIT MOVEMENT OF <br />EQUIPMENT, <br />7. PERFORM ALL EXCAVATING, BACKFILLING, CUTTING AND REPAIRING REQUIRED FOR <br />INSTALLATION OF ELECTRICAL WORK, <br />B. CONTRACTOR SHALL X-RAY FLOOR SLABS, WALLS, OR CEILING CONCRETE PRIOR TO ALL <br />CORE DRILLINGS. <br />N. C❑NDUITi FEEDERS AND BRANCH CIRCUIT HOME RUNS SHALL BE CONSTRUCTED OF EMT WITH ALL <br />STEEL RAINTIGHT OR SET -SCREW FITTINGS, CONNECTORS SHALL BE INSULATED THROAT TYPE, <br />PR❑VIDE METALLIC BUSHINGS WITH PLASTIC INSERTS FOR 3' OR LARGER. C❑NDUITS FEEDING OR <br />CONNECTING TO EQUIPMENT PROVIDED BY OTHER TRADES SHALL NOT BE INSTALLED UNTIL SUCH <br />EQUIPMENT IS INSTALLED OR UNTIL SPECIFIC R❑UGH-IN INSTRUCTIONS ARE PROVIDED BY THE <br />TRADE PROVIDING THE EQUIPMENT. UNLESS OTHERWISE INDICATED, CONDUITS SHALL BE <br />CONCEALED, RACEWAYS INSTALLED IN OR UNDER SLABS, ON GRADE, OR AS EXTERIOR DUCT BANKS <br />SHALL BE PVC SCHEDULE 40 OR 80. RUN EXPOSED C❑NDUITS PARALLEL OR PERPENDICULAR TO <br />STRUCTURAL ELEMENTS, TWO OR MORE RACEWAYS RUN TOGETHER SHALL BE INSTALLED ON GANG <br />TRAPEZE TYPE HANGERS, SUCH RACEWAYS ASSEMBLIES SHALL BE RUN PARALLEL OR <br />PERPENDICULAR TO STRUCTURAL ELEMENTS. C❑NDUITS EMBEDDED IN SLABS SHALL HAVE A <br />MINIMUM OF 1' COVER OF CONCRETE ON ALL SIDES, OUTSIDE DIAMETER OF CONDUIT SHALL NOT <br />EXCEED 1/3 OF THE SLAB THICKNESS. PROVIDE 0.25' NYLON PULL TAPE IN ALL EMPTY <br />C❑NDUITS, BRANCH CIRCUITS MAY UTILIZE TYPE MC ARMORED CABLE ASSEMBLY WITH COPPER <br />CONDUCTORS AND FULL SIZE EQUIPMENT GROUNDING CONDUCTORS FOR INDIVIDUAL DROPS TO <br />DEVICES. TYPE MC CABLE SHALL BE SUPPORTED AT 48' INTERVALS AND SHALL NOT LAY ON <br />THE CEILING GRID OR INTERFERE WITH THE REMOVAL OF CEILING. <br />0, CONDUCTORS, ALL BUILDING WIRE SHALL BE 600 VOLT RATED THHN OR THWN COPPER, STRANDED <br />FOR SIZES #8AWG AND LARGER, S❑LID FOR SIZES 10 AND SMALLER UNLESS APPLIED FOR <br />CONTROL. ALL BUILDING WIRE AND SPECIAL CABLES FOR SYSTEMS SHALL BE INSTALLED IN A <br />RACEWAY, ALL WIRE AND CABLE SHALL BE DELIVERED TO THE J❑BSITE IN ORIGINAL UNBROKEN <br />PACKAGES, CARTONS OR REELS, WITH THE MANUFACTURERS NAME, UL LABEL, AND <br />CHARACTERISTICS OF THE PRODUCT PLAINLY VISIBLE. ALL WIRE AND CABLE SHALL BE <br />MANUFACTURED IN THE UNITED STATES OF AMERICA. WIRES SHALL BE COLOR CODED AS FOLLOWS <br />(A,B,C,N,G)i 120/208-BLACK, RED, BLUE, WHITE, GREEN] 480/277 - BROWN, ORANGE, YELLOW, <br />GRAY, GREEN. SPLICES SHALL BE COMPRESSION TYPE. CONTROL CONDUCTORS SHALL BE <br />TERMINATED WITH INSULATED CONNECTORS, T&B STAK❑N. 120 VOLT CIRCUITS WITH H❑MERUN <br />LENGTH OVER 125 FEET AND 277 VOLT CIRCUITS WITH A H❑MERUN LENGTH OVER 250 FEET <br />SHALL HAVE #10 MINIMUM HOMERUN CONDUCTORS. ALL THREE PHASE BRANCH CIRCUITS WITH A <br />COMMON NEUTRAL SHALL HAVE #10 MINIMUM NEUTRAL. <br />P. B❑XESi OUTLET BOXES SHALL BE SHEET STEEL, MINIMUM 4' SQUARE, MINIMUM 1.5' DEEP, WITH <br />PLASTER RING IN PLASTER OR BRICK CONSTRUCTION, OUTLETS BOXES IN POURED CONCRETE <br />SHALL BE CONCRETE RINGS, MASONRY BOXES SHALL BE USED IN MASONRY OR TILE <br />CONSTRUCTION. OUTLET BOXES FOR SURFACE ALUMINUM RACEWAY SHALL BE 4-11/16 WITH <br />PLASTER RINGS ORIENTED HORIZONTALLY, BOXES SHALL BE SECURELY ANCHORED IN PLACE, AND <br />SHALL BE SUPPORTED INDEPENDENT OF THE RACEWAY SYSTEM. PULL BOXES SHALL BE <br />GALVANIZED SHEET STEEL, MINIMUM 12 GAUGE, WITH SCREW COVERS, AND WELDED <br />CONSTRUCTION. WELDS SHALL BE COLD GALVANIZED, USING PERMANENT WATER PROF WIDE <br />BLACK MARKER, CLEARLY LABEL COVER OF ALL BRANCH CIRCUIT JUNCTION AND PULL BOXES <br />WITH PANEL AND CIRCUIT NUMBER OF CIRCUITS CONTAINED IN OR PASSING THROUGH THE BOX. <br />BRANCH CIRCUIT AND FEEDER JUNCTION AND PULL BOXES USED WITH EMERGENCY FEEDERS AND <br />CIRCUITS SHALL BE PAINTED RED. PR❑VIDE P-TOUCH OR DYM❑ LABELS ON COVER OF EACH <br />FEEDER PULL OR JUNCTION BOX INDICATING FEEDER DESIGNATION, SOURCE, LOAD, AND VOLTAGE. <br />Q. WIRING DEVICES, SWITCHES FOR LIGHTING CIRCUITS SHALL BE 120/277 VOLT, 20 AMP, A.C. <br />ONLY, QUIET TYPE, WITH GROUND BONDING SCREW, SPECIFICATION GRADE. MOMENTARY CONTACT <br />SWITCHES SHALL BE SINGLE POLE DOUBLE THROW, CENTER OFF GE #5935 OR EQUAL. DUPLEX <br />RECEPTACLES SHALL BE 15 AMP HUBBELL 5262 OR EQUAL. DEDICATED DUPLEX RECEPTACLES <br />SHALL BE ORANGE 20AMP HUBBELL IG5362 OR EQUAL, SPECIAL RECEPTACLES SHALL BE OF <br />SIMILAR CONSTRUCTION. FACE PLATES SHALL BE SMOOTH NYLON OR THERMOSET PLASTIC. <br />ADJACENT OUTLETS SHALL BE INSTALLED IN MULTI -GANG BOXES WITH A SINGLE MULTI -GANG <br />FACE PLATE, RECEPTACLES CONNECTED TO AN EMERGENCY CIRCUIT SHALL BE RED. C❑❑RDINATE <br />COLOR OF DEVICES AND FACEPLATE WITH ARCHITECT, <br />R. GR❑UNDINGi ALL FEEDERS AND BRANCH CIRCUITS SHALL BE PR❑VIDED WITH INSULATED GREEN <br />EQUIPMENT GROUNDING CONDUCTOR. C❑NDUIT GROUNDS ONLY ARE NOT PERMITTED, <br />S. LIGHTING+ SPARE FLUORESCENT LAMPS SHALL MATCH BUILDING STANDARD UNLESS OTHERWISE <br />NOTED, INCANDESCENT LAMPS SHALL BE 130VOLT, NEW BALLASTS SHALL BE SOILD STATE <br />ELECTR❑NIC, EXIT FIXTURES SHALL MATCH BUILDING STANDARD, FIXTURE LOCATIONS SHALL BE <br />AS SHOWN ON THE REFLECTED CEILING PLAN, PROVIDE LAY -IN FIXTURES WITH TWO REMOVABLE <br />CLIPS ATTACHING FIXTURE TO CEILING GRID. FLANGED FIXTURES SHOWN TO BE INSTALLED IN <br />C❑NTINU❑US ROWS SHALL NOT HAVE INTERMEDIATE FLANGES. ALL PENDANT FIXTURES SHALL BE <br />MOUNTED TO STRUCTURE, SEISMIC SUPPORT WIRES AND/OR COMPRESSION STRUTS FOR LAY -IN <br />FIXTURES SHALL BE SUBJECT TO LOCAL AHJ LATEST REQUIREMENTS. <br />T. FIRE ALARM DEVICES NEW FIRE ALARM DEVICES SHALL BE COMPATIBLE WITH EXISTING <br />BUILDING ADDRESSABLE FIRE ALARM SYSTEM. INSTALL NEW DEVICES AND CONNECT TO NEAREST <br />SIGNALING OR NOTIFICATION DEVICE CIRCUIT WITHIN THE AREA, CONTRACTOR SHALL VERIFY <br />CIRCUIT HAS CAPACITY FOR ADDED LOAD. SYSTEM SHALL BE CERTIFIED BY FIRE ALARM VENDOR <br />AFTER COMPLETION OF WORK. <br />U. PANELBOARDS, DEAD FRONT PANEL CONSTRUCTION WITH SEPARATELY MOUNTED INTERIOR TRIM. <br />MAIN AND BRANCH DEVICES SHALL BE BOLT -ON, MULTI -POLE BREAKERS SHALL BE COMMON TRIP, <br />WIDTH SHALL NOT EXCEED 22' FOR PANELB❑ARD AND ENCLOSURE SHALL MATCH BUILDING <br />STANDARD. PROVIDE GROUND BUS IN PANELB❑ARD AND PROVIDE DEVICE MOUNTING HARDWARE <br />WHERE A SPACE IS SCHEDULED. PANEL AND OCPD SHORT CIRCUIT RATINGS SHALL BE AT LEAST <br />10% GREATER THAN AVAILABLE SHORT CIRCUIT CURRENT AT PANELB❑ARD, <br />V. DRY -TYPE TRANSFORMERS TRANSFORMERS SHALL BE DRY -TYPE, ENCLOSED, SELF -COOLED, <br />VENTILATED TYPE, DEAD -FRONT DRIP PROOF, PRIMARY AND SECONDARY TAPS SHALL BE <br />ACCESSIBLE FROM THE FRONT. TRANSFORMERS SHALL MEET OR EXCEED BUILDING STANDARD <br />TRANSFORMERS SPECIFICATIONS. PROVIDE AN EQUIPMENT GROUNDING CONDUCTOR IN THE PRIMARY <br />FEED TO THE TRANSFORMER, SUPPLEMENTAL GROUND TO NEAREST ACCESSIBLE PRIMARY <br />STRUCTURAL MEMBER OR EQUIPMENT ROOM GROUND BUS BAR. SIZE PER NEC AND RUN IN C❑NDUIT <br />WITH BOND BUSHING AT EACH END. NEUTRAL AND GROUNDING CONDUCTOR SHALL BE BONDED TO <br />ENCLOSURE. <br />li <br />Fri'! <br />U <br />Ono <br />�NT <br />� <br />Zwo F- <br />V <br />�..ACDmm <br />�NoN <br />A �U co <br />U)co� <br />wE*Uwse <br />.uzo <br />w W p <br />V ~J co <br />ri Q Z U <br />V p CNI <br />CN <br />LL <br />0 <br />Lo <br />0 <br />v <br />�aaaaarr�f� <br />$ter <br />f:r <br />BPJ�ygt�4�i <br />2-15-16 <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />CONTRACT DATE: <br />BUILDING TYPE: <br />PLAN VERSION: <br />SITE NUMBER: <br />STORE NUMBER: <br />01.05.2016 <br />N/A <br />DEC 2015 <br />N/A <br />N/A <br />SHELL BUILDOUT <br />5935 GALL BLVD <br />ZEPHYRHILLS, FL 33541 <br />REMODEL <br />PHASE 1 <br />ELECTRIAL <br />SPECIFICATIONS <br />EOmO <br />PLOT DATE: <br />