GENERAL PLUMBING NOTES <br />�I✓ <br />CONNECT TO <br />WC-2 <br />NICKLE BRONZE ADJUSTABLE <br />SCORIATED SECURED COVER. <br />FLUSH WITH <br />FLOOR LINE BRONZE TAPER THREAD PLUG <br />WITH COUNTER SUNK HEAD <br />45' WYE AND 1/8TH BEND <br />FITTING OR COMBINATION FLANGE <br />FITTING <br />WASTE LINE LENGTH <br />TO SUIT <br />�Iml <br />NOTE: <br />CLEAN -OUT TO BE J.R. SMITH MODEL 4100-F SERIES OR EQUAL INSTALLATION SHALL BE <br />LV-1 FLUSH WITH SURROUNDING FLOOR SURFACES. <br />FLOOR CLEANOUT DETAIL <br />PLUMBING FIXTURE SCHEDULE <br />FIXTURE TAG <br />DRAIN <br />VENT <br />CW <br />HW <br />FIXTURE DESCRIPTION <br />FIXTURE SPECIFICATION <br />VALVE/FACUET SPECIFICATION <br />WC-1 <br />3 <br />1-1/2" <br />3/4" <br />KOHLER WELLWORTH <br />ELONGATED PRESSURE ASSIST TANK -TYPE TOILET. CENTOCO 500 STSCCSS, EXTRA HEAVY DUTY SOLID PLASTIC, ELONGATED OPEN FRONT SEAT, WHITE, <br />SLOAN FLUSH -MATE PRESSURE ASSIST <br />WATER CLOSET - TANK <br />K3493 <br />COVER WITH SLOW CLOSE SNAP -OFF HINGES. TANK COVER LOCK. <br />WC-2 <br />3 <br />1-1/2" <br />3/4" <br />KOHLER HIGHLINE <br />ELONGATED PRESSURE ASSIST TANK -TYPE TOILET. CENTOCO 500 STSCCSS, EXTRA HEAVY DUTY SOLID PLASTIC, ELONGATED OPEN FRONT SEAT, WHITE, <br />SLOAN FLUSH -MATE PRESSURE ASSIST <br />ADA WATER CLOSET - TANK <br />K3505 <br />COVER WITH SLOW CLOSE SNAP -OFF HINGES. TANK COVER LOCK. ADA COMPLIANT. <br />UR-1 <br />2 <br />1-1/4" <br />3/4" <br />SLOAN <br />VITREOUS CHINA, WALL HUNG SIPHON JET WITH FLUSHING RIM, 3/4" TOP SPUD; JAY R. SMITH 0644 FLOOR CARRIER. MOUNT AT HANDICAP HEIGHT. <br />MANUAL FLUSH <br />URINAL <br />SU-1005-.5 <br />SLOAN ROYAL180-1.0 <br />LV-1 <br />1.5 <br />1.25 <br />0.5 <br />0.5 <br />PROFLOW <br />VITREOUS CHINA, 19"X15" SELF RIMMIN WITH OVERFLOW & GRID DRAIN, 4" CENTERS; PROVIDE CHROME PLATED LOOSE KEY ANGLE STOP, P-TRAP, <br />KOHLER K-7404 4" CENTERS <br />COUNTER -MOUNT LAVATORY <br />PF20174 <br />ESCUTCHEON AND SUPPLIES. INSTALLED PER ADA ACCESSIBILITY. <br />MANUALTWO - LEVER WITH WRISTBLADES <br />SK-1 <br />1.5 <br />1.25 <br />0.5 <br />0.5 <br />ELKAY <br />SINGLE COMPARTMENT, 20-GAUGE 304 STAINLESS STEEL SELF -RIMMING, FULLY COATED UNDERSIDE; DELTA FAUCET 21984LF, 3-HOLES WITH 4TH HOLE FOR <br />LARGE SINGLE BOW SINKL <br />LRAD312255 <br />SPRAY NOZZLE, SWIVEL GOOSENECK SPOUT, INSTALL PER ADA ACCESSIBILITY. <br />FD-1 <br />3 <br />1.5 <br />JAY R. SMITH <br />CAST IRON BODY AND FLASHING COLLAR; 6" NICKEL BRONZE ROUND STRAINER; VANDLE PROOF GRATE; P-050 TRAP PRIMER OPTION. CAST IRON GRATES <br />FLOOR DRAIN <br />2010.00 <br />NOT PERMITTED. <br />FCO-1 <br />4 <br />JAY R. SMITH <br />CAST IRON CLEANOUT; NICKEL BRONZE 6" ROUND ADJUSTABLE SCORIATED VANDAL PROOF TOP; GASKET SEAL ABS THREADED PLUG WITH SLOT TO <br />FLOOR CLEAN OUT <br />4020S <br />RECEIVE 1/2" BAR STOCK. ARFCO- ACID RESITANT OPTION. <br />WCO-1 <br />4 <br />JAY R. SMITH <br />CAST IRON SPIGOT FERRULE; CAST BRONZE TAPER THREADED COUNTERSUNK PLUG WITH SLOT TO RECEIVE 1/2" BAR STOCK <br />WALL CLEAN OUT <br />4420.00 <br />EWC-1 <br />1.5 <br />1.25 <br />0.5 <br />OASIS <br />WALL HUNG, BARRIER FREE. SPLIT LEVEL, ALL STAINLESS STEEL CABINET; 8 GPH OF 50' WATER AT 90 'AMBIENT; 1/4 HP, 120V/1 PH. PROVIDE QUARTER <br />ELEC WTR COOLER <br />P8ACSL <br />TURN ANGLED STOP, P-TRAP AND SUPPLIES. INSTALLED PER ADA ACCESSIBILITY. <br />WHA <br />JAY R. SMITH 5000 SERIES <br />STAINLESS STEEL PRESSURIZED COMPRESSION CHAMBER; THREADED NIPPLE CONNECTION; SIZE AS INDICATED ON DRAWINGS <br />WATER HAMMER ARRESTOR <br />MS-1 <br />3 <br />1.5 <br />0.75 <br />0.75 <br />FIAT <br />ONE PIECE SERVICE BASIN; AND 3.0 GPM FLOW RESTRICTOR; DELTA 28T910 STAINLESS STEEL MOP HOLDER; 28T911 HEAVY DUTY 31" LONG REINFORCED <br />DELTA 28T9 <br />MOP SERVICE BASIN <br />MSB-3636 OR 24X24 <br />HOSE, BRASS COUPLING, STAINLESS STEEL HANGER BRACKET, W/RUBBER GRIP. <br />WITH INTERGRAL VACUUM BREAKER <br />MXV-1 <br />.75(X2) <br />POWERS <br />MULTI -FIXTURE MIXING VALVE, SOLID BRASS WITH INTEGRAL CHECK. THREADED UNION CONNECTIONS. ASSE1017 <br />MIXING VALVE <br />LM490 <br />TP-1 <br />0.5 <br />PPP <br />PRESSURE ACTIVATED TRAP PRIMER- PROVIDE DISTRIBUTION FITTING FOR UP TO 4 OUTLETS AS SHOWN ON DRAWINGS. <br />PRESSURE ACT.TRAP PRIMER <br />PR-500 <br />1. ALL FIXTURES, EQUIPMENT, TRIM, FITTINGS, ETC. SHALL COMPLY WITH LOCAL, STATE AND/OR FEDERAL REGULATIONS AND CODES, INCLUDING BUT NOT LIMITED TO WATER AND ENERGY CONSERVATION CODES, AND THE AMERICANS WITH DISABILITIES ACT (ADA). THE SCHEDULE REFLECTS FIXTURES AND EQUIPMENT <br />WHICH ARE MINIMUM CRITERIA AND SHALL BE THE BASIS FOR CONTRACTORS BASE BID. WHERE SPECIFIED FIXTURES AND/OR EQUIPMENT ARE NOT IN COMPLIANCE WITH GOVERNING CODES AND REGULATIONS, THE CONTRACTOR SHALL PROVIDE AN ALTERNATE BID FOR THE SUBSTITUTIONS OF COMPLYING FIXTURES, <br />EQUIPMENT, FITTINGS, ETC. THE ABSENCE OF AN ALTERNATE BID SHALL BE CONSTRUED TO MEAN THAT THE CONTRACTORS BASE BID INCLUDES ALL COSTS NECCESSARY TO MEET ALL REGULATIONS AND CODES. <br />WATER HEATER SCHEDULE <br />LAYOUT <br />STORAGE <br />GAS INPUT <br />OUTPUT <br />ELECTRICAL <br />GPH RECOVERY <br />TEMP <br />ELEC <br />EXPANSION TANK <br />MARK <br />TYPE <br />BASIS <br />GALLONS <br />MBH <br />MBH <br />CAPACITY KW <br />@80 DEG RISE <br />SETTING <br />VOLT/PHASE <br />ACCPETANCE GAL <br />WH-1 <br />ELEC STORAGE <br />PROMAX <br />40 <br />-- <br />-- <br />4.5KW <br />60.00 <br />110 <br />208/1 <br />5 <br />1. PROVIDE ARMSTRONG LST EXP TANK AND T&P SET AT 150 PSI DISCHARGE TO HUB DRAIN. DO NOT ROUTE INTO DRAIN PAN. <br />2. PROVIDE 2" DEEP DRAIN PAN BENEATH STORAGE TYPE WATER HEATER TO ENCASE ENTIRE <br />WATER HEATER <br />FOOTPRINT. <br />TINSTALL PER PDI <br />STANDARDS AND <br />MANUFACTURER'S <br />PDI I i INSTRUCTIONS. <br />SIZE PROVIDE A WHA <br />„A„ AT ALL QUICK - <br />CLOSING VALVES. <br />SINGLE FIXTURE <br />PDI <br />SIZE <br />PIPE <br />SIZE <br />FIXTURE <br />UNIT LOAD <br />A <br />1/2" <br />1-11 <br />B <br />3/4" <br />12-32 <br />C <br />1" <br />33-60 <br />D <br />1-1/4" <br />61-113 <br />E <br />1-1/2" <br />114-154 <br />F <br />2" <br />154-330 <br />r- HOT OR COLD WATER SUPPLY <br />IF HORIZONTAL BRANCH IS LESS THAN 20' <br />LONG, PROVIDE ONE WHA AT END OF LINE. <br />IF BRANCH IS GREATER THAN 20' LONG, <br />PROVIDE ANOTHER WHA IN MIDDLE, EACH <br />SIZED FOR HALF THE FIXTURE UNITS. - <br />MULTIPLE FIXTURES <br />FIXTURE UNIT TABULATION <br />FIXTURE <br />COLD <br />HOT <br />VALVE WATER CLOSET <br />10 <br />-- <br />TANK WATER CLOSET <br />3 <br />-- <br />LAVATORY/SINK <br />2 <br />2 <br />SHOWER/BATHTUB <br />2 <br />2 <br />DO NOT PROVIDE AIR CHAMBERS. PROVIDE WATER HAMMER ARRESTERS BY SIOUX CHIEF, <br />PRECISION PLUMBING PRODUCTS, WATTS OR APPROVED EQUIVALENT WITH PISTON AND 0-RING <br />CONSTRUCTION, HAVING PDI #WH-201, ASSE # 1010 AND ANSI # Al 12.26.1 M CERTIFICATION. <br />INSTALL IN HORIZONTAL OR VERTICAL POSITION, BUT NEVER UPSIDE DOWN. INSTALL IN LINE <br />WITH WATER FLOW IF POSSIBLE. SIZE THE UNITS AS SHOWN ON THE DRAWINGS AND/OR PER THE <br />TABLES SHOWN ABOVE. SIOUX CHIEF "MINI -RESTER" MAY BE USED AT EACH FIXTURE. PROVIDE <br />ACCESSIBILITY TO "WHA" WHERE REQUIRED BY LOCAL CODE. <br />1. THESE DRAWINGS ARE SCHEMATIC IN NATURE AND ARE NOT INTENDED TO SHOW ALL POSSIBLE CONDITIONS. IT IS INTENDED THAT A COMPLETE PLUMBING AND <br />FIRE PROTECTION SYSTEM BE PROVIDED WITH ALL NECESSARY EQUIPMENT, APPURTENANCES AND CONTROLS COMPLETELY COORDINATED WITH ALL DISCIPLINES. <br />ALL PARAMETERS GIVEN IN THESE DOCUMENTS SHALL BE STRICTLY CONFORMED TO. ANY ITEMS AND LABOR REQUIRED FOR A COMPLETE PLUMBING AND FIRE <br />PROTECTION SYSTEM IN ACCORDANCE WITH ALL APPLICABLE CODES, STANDARDS, LOCAL AUTHORITIES AND THESE CONTRACT DOCUMENTS SHALL BE FURNISHED <br />WITHOUT INCURRING ANY ADDITIONAL COST TO THE OWNER. CAREFULLY REVIEW ALL CONTRACT DOCUMENTS AND THE DESIGN OF OTHER TRADES BEFORE <br />PREPARING SHOP DRAWINGS. <br />2. COORDINATE ALL WORK WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL, AND ELECTRICAL TRADES. PIPE ROUTING SHOWN IS DIAGRAMMATIC. PROVIDE ALL <br />OFFSETS, ETC. TO AVOID INTERFERENCES WITH EQUIPMENT, PIPING, DUCT WORK, LIGHTS, CONDUITS, AND STRUCTURAL ITEMS, ETC... <br />3. ALL DRAINAGE PIPING AND POTABLE WATER PIPING SHALL BE CONCEALED INSIDE WALLS AND PIPE CHASES OR ABOVE CEILINGS AS HIGH AS POSSIBLE. <br />4. EXPOSED PIPING AT FIXTURES SHALL BE SECURED TO WALLS CONSTRAINED AGAINST ANY FREE -MOVEMENT OF PIPING. <br />5. CONTRACTOR SHALL MAKE FINAL CONNECTION TO ALL DOMESTIC WATER, SANITARY SEWERS, STORM DRAINS, FIRE SUPPLY AND GAS SERVICES AT <br />APPROXIMATELY 5'-0" FROM BUILDING STRUCTURE UNLESS OTHERWISE NOTED. <br />6. REFER TO ARCHITECTURAL PLANS AND ELEVATIONS FOR LOCATION OF ALL PLUMBING FIXTURES. EXACT LOCATION OF ALL PLUMBING FIXTURES MUST BE VERIFIED <br />IN FIELD PRIOR TO INSTALLATION. FINAL LOCATIONS AND HEIGHTS SHALL BE AS DIRECTED BY ARCHITECT. <br />7. PLUMBING CONTRACTOR SHALL MAKE FINAL CONNECTION TO ALL EQUIPMENT INDICATED ON DRAWINGS INCLUDING KITCHEN AND LAUNDRY EQUIPMENT PER <br />MANUFACTURER'S SPECIFIC INSTALLATION INSTRUCTIONS. FINAL CONNECTION SHALL INCLUDE ANY ADAPTERS, NIPPLES SHUTOFF VALVES, PRESSURE <br />REGULATING VALVES, SHOCK ABSORBERS, BACKFLOW PREVENTION DEVICES, ETC. CONTRACTOR SHALL COMPLETELY REVIEW EACH EQUIPMENT ITEM'S <br />INSTALLATION INSTRUCTIONS PRIOR TO COMMENCEMENT OF WORK. ALL ITEMS REQUIRED FOR INSTALLATION ARE INCLUDED IN THE PLUMBING CONTRACTOR'S <br />SCOPE. <br />8. DO NOT RUN PLUMBING OR FIRE PROTECTION PIPING THROUGH TRANSFORMER VAULTS, ELECTRICAL CLOSETS, ELECTRICAL SWITCHGEAR ROOMS, ELEVATOR <br />EQUIPMENT ROOMS, COMPUTER ROOMS OR TELEPHONE ROOMS. DO NOT RUN ANY PIPING ABOVE ELECTRICAL PANELS OR OTHER ELECTRICAL/CONTROLS <br />COMPONENTS. <br />9. ALL COMMERCIAL FIXTURES SPECIFIED BY AN EQUIPMENT PROVIDER SHALL OVERRIDE ANY SPECIFIED PLUMBING FIXTURES ON THIS PLAN. THE PLUMBER SHALL <br />COORDINATE FINAL REQUIRED FIXTURES WITH OWNER/EQUIPMENT SUPPLIER. VERIFY CONNECTION SIZE AND LOCATION OF ALL ITEMS WITH KITCHEN EQUIPMENT <br />DRAWINGS. <br />10.PROVIDE AN EXPANSION JOINT ON ALL PIPING SYSTEMS THAT CROSS BUILDING EXPANSION JOINTS. <br />11.PROVIDE CONNECTION TO EXISTING WATER SERVICE WHERE AVAILABLE. PROVIDE WATER METER, PRV STATION WITH FULL SIZE BYPASS, AND RPZ VALVE. <br />COORDINATE METER AND BACKFLOW REQUIREMENTS WITH LOCAL AUTHORITY AND UTILTIY COMPANIES. CONNECT TO EXISTING SANITARY AND KITCHEN WASTE <br />STUB WHERE AVAIALBLE. CONNESTIONS TO EXISTING UTILTIES SHALL BE COORDINATED IN THE FIELD FOR EXACT LOCATION AND INVERT AVAILABILITY. <br />12.PROVIDE GAS CONNECTION TO EXISTING METER WHERE POSSIBLE. PROVIDE CONNECTION TO ROOF MOUNTED EQUIPMENT AND TO KITCHEN EQUIPMENT AS <br />INDICATED ON KITCHEN EQUIPMENT DRAWING. PROVIDE SHUT-OFF VALVES AT ALL POINTS OF CONNECTION. PROVIDE SOLENOID SHUT-OFF VALVE FOR GAS ITEMS <br />UNDER KITCHEN HOODS. INTERLOCK SOLENOID WITH HOOD FIRE PROTECTION SYSTEM. GAS PIPING SHALL NOT BE ROUTED BELOW FLOORS. PIPING INDICATED AS <br />BELOW SLAB SHALL BE PROVIDED IN A PREFABRICATED MODULAR STAINLESS STEEL UTILITY TRENCH. <br />13.ALL PLUMBING FIXTURES, PIPING, AND MATERIALS SHALL BE LISTED OR LABELED AND INSTALLED AS PER A RECOGNIZED APPROVAL AGENCY. <br />14.ALL WORK WITHIN THIS SCOPE OF WORK SHALL COMPLY WITH ALL CITY, STATE AND NATIONAL PLUMBING CODES. ALL WORK SHALL CONFORM TO BUILDING <br />STANDARDS. <br />15.PLUMBING CONTRACTOR SHALL VERIFY VOLTAGE, PHASE AND WIRE SIZE OF PLUMBING EQUIPMENT REQUIRING ELECTRICAL CONNECTION WITH ELECTRICAL <br />CONTRACTOR PRIOR TO PURCHASE OF EQUIPMENT <br />16.ALL PLUMBING UTILTIY AND SERVICE REQUIREMNTS SHALL BE COORDINATED BY THE CONTRACTOR WITH THE LOCAL CODE AUTHORITIES AND UTILITY COMPANIES. <br />ANY ADDITIONAL REQUIREMENTS FOR UTILTY SERVICES SHALL BE INCLUDED IN CONTRACTOR SCOPE. <br />17.COORDINATE ALL UNDERGROUND PIPING WITH GRADE BEAMS, WALL FOOTINGS, COLUMN FOUNDATIONS AND OTHER STRUCTURAL CONDITIONS. <br />18.ALL DRAINAGE PIPING AND VENT PIPING SHALL SLOPE AT 1/8 INCH PER FOOT UNLESS OTHERWISE NOTED. <br />19.FLOORS WHERE INDICATED ON ARCHITECTURAL AND /OR STRUCTURAL DRAWINGS SHALL SLOPE TO FLOOR DRAINS. MAXIMUM SLOPE IN ANY DIRECTION SHALL <br />NOT EXCEED 1/4 INCH PER FOOT. EXACT LOCATION OF ALL FLOOR DRAINS AND HUB DRAINS FOR EQUIPMENT MUST BE VERIFIED IN FIELD PRIOR TO INSTALLATION. <br />FINAL LOCATION SHALL BE AS DIRECTED BY ARCHITECT. FLOOR DRAIN SHALL BE COMPLETELY FLUSH WITH THE LOWEST LEVEL OF THE FLOOR SLOPE AND SHALL <br />NOT PROTRUDE BEYOND THE FLOOR SO AS TO CAUSE POOLING AROUND THE DRAIN. CUTTING OF ANY FLOOR DRAINAGE FIXTURE GRATE SHALL NOT BE PERMITTED <br />20. EXACT LOCATION OF ALL CLEANOUTS MUST BE COORDINATED AND APPROVED BY ARCHITECT PRIOR TO INSTALLATION. <br />21. COORDINATE ALL FIXTURE GRATES, ORIENTATIONS, AND REQUIRED GRATE SPACING WITH THE KITCHEN EQUIPMENT SUPPLIER. VERIFY ALL FLOOR DRAIN AND <br />FLOOR SINK LOCATIONS WITH THE KITCHEN CONSULTANT. HALF -GRATES SHALL BE PROVIDED FOR HUB DRAIN COLLECTING INDIRECT SINK DISCHARGE. <br />CONTRACTOR SHALL COORDINATE FINAL FLOOR SINK LOCATIONS WITH SINK SUPPORT LEGS TO AVOID SUPPORTS SITTING ON GRATES. <br />22. SANITARY VENTS MUST TERMINATE A MINIMUM OF 10 FT. FROM OR 2 FT. ABOVE AIR INTAKES, WINDOWS OR VENT SHAFTS. <br />23. INDIRECT WASTE RECEPTORS MUST BE LOCATED WHERE READILY ACCESSIBLE FOR INSPECTION AND CLEANING. <br />24. ALL HOSE BIBBS AND WASHDOWN FAUCETS ARE REQUIRED TO HAVE PROPER BACKFLOW PREVENTERS WHERE HOSES ARE ATTACHED AND LEFT UNATTENDED. <br />CHEMICAL FEED SYSTEMS AT COMMERCIAL KITCHENS SHALL HAVE DEDICATED BACKFLOW PREVENTERS SEPARATE FROM WASHO-DOWN OR HOSE BIB FIXTURES. <br />25. PVC PIPING SHALL BE PROHIBITTED IN ANY AIR PLENUM SPACES. PIPING SHALL NOT BE PROVIDED WITHING INSULATED COOLER/FREEZER PANEL WALLS. <br />26. PROVIDE 12" x 12" ACCESS PANELS FOR SHOCK ABSORBERS, TRAP PRIMERS AND ALL VALVES LOCATED ABOVE NON -ACCESSIBLE CEILINGS AND INSIDE PIPE <br />CHASES. EXACT LOCATION MUST BE COORDINATED WITH ARCHITECTURAL DRAWINGS AND APPROVED BY ARCHITECT PRIOR TO INSTALLATION. ALL ACCESS <br />PANELS SHALL BE LOCATED SO THAT THEY ARE NOT VISIBLE TO PUBLIC VIEW. <br />27. WALL HYDRANTS AND HOSE BIBBS SHALL BE MOUNTED 1'- 6" ABOVE GRADE OR FLOOR LEVELS. <br />28. PIPING ISULATION SHALL BE PROVIDED WITH CONTIUOUS AIR -TIGHT VAPOR BARRIER WITH NO LOOSE TAPE OR EXPOSED INSULATION MATERIAL. CONDENSATE <br />PIPING SHALL BE PROVIDED WITH ELASTOMERIC INSULATION. ALL INSULATION AND WRAPPING JOINTS AND SEEMS SHALL BE PROVIDED WITH 1 OVERLAP AND <br />MANUFACTURER RECOMMENDED, AIR-TIGH MASTIC AT ANY INSULATION OR VAPOO BARTER JOINTS. INSULATION SHALL BE INSTALLED WITH FULL THICKNESS, FREE <br />OF ANY INSUALTION COMPRESSION. PROVIDE RIGID INSULATION SECTION AT ALL PIPING HANGERS, <br />29. PROVIDE REDUCED PRESSURE BACKFLOW PREVENTER AT ALL CONNECTIONS TO MECHANICAL EQUIPMENT, KITCHEN AND LAUNDRY EQUIPMENT, IRRIGATION AND <br />POOL CONNECTIONS, WATER SOFTENERS, VENDING MACHINES, ETC. AS REQUIRED BY CODE AND LOCAL AUTHORITIES. CONTRACTOR IS TO VERIFY WITH THE LOCAL <br />AUTHORITY THE TYPE OF BACKFLOW PREVENTION DEVICE REQUIRED FOR ALL APPLICATIONS PRIOR TO INSTALLATION. DRAINAGE FIXTURE AND PIPING (HUB <br />DRAIN/FLOOR DRAIN ETC) SHALL BE PROVIDED FOR EACH BFP CONTAINING A BACKFLOW DISCHARGE. <br />30. EXTEND ALL PVC CONDUITS CONTAINING BEVERAGE LINES, HOT AND COLD WATER PIPING, ETC. BELOW FLOOR/GROUND A MINIMUM OF ONE INCH ABOVE FINISHED <br />FLOOR AND SEAL AROUND PIPING TO ENSURE WATER- TIGHT CONNECTIONS. OFFSET ALL PVC BEVERAGE CONDUITS WITH 24" MINIMUM RADIUS FITTINGS. REFER <br />TO KITCHEN EQUIPMENT DRAWINGS FOR ADDITIONAL DETAILS AND REQUIREMENTS. <br />31. PROVIDE A VALVED BYPASS AT ALL EQUIPMENT INCLUDING WATER HEATERS, STORAGE TANKS WATER SOFTENERS, BOOSTER PUMPS, FIRE PUMPS, ETCO FOR <br />MAINTENANCE OF EQUIPMENT. <br />32. PROVIDE BALL VALVES AT ALL BRANCH LINES SERVING MULTIPLE FIXTURES. PROVIDE ACCESSIBLE BALL VALVE AT EACH FIXTURE CONNECTION (IN ADDITION TO <br />ANY EXPOSED STOPS) OR FIXTURE HEADER BRANCH CONNECTION. <br />33. INSTALL VACUUM BREAKERS A MINIMUM OF 6" ABOVE THE FLOOD LEVEL RIM OF A FIXTURE SERVED WITH NO SHUT-OFF DEVICES BEYOND THE DISCHARGE OF THE <br />VACUUM BREAKER. <br />34. THE USE OF RISER CLAMPS TO SUPPORT VERTICAL PIPE ALONG WALLS, OR COLUMNS IS PROHIBITED. PROVIDE B-LINE 22 STRUT & B-2000 PIPE CLAMPS <br />35. CONTRACTOR SHALL HANG ALL PIPING FROM THE STRUCTURAL MEMBERS (W-SHAPES, BAR JOISTS) WITH CLAMP -TYPE CONNECTIONS. PIPING SHALL NOT BE <br />SUPPORTED FROM THE METAL DECK. STRUCTURAL MEMBERS SHALL NOT BE CUT OR DRILLED. <br />36. ALL JOINTS, ANNULAR SPACES, OR OPENINGS INTO HOLLOW OR INACCESSIBLE AREAS ARE TO BE CLOSED TO 1/32" OR LESS FOR FOOD SERVICE AREAS. <br />37. ALL ANNULAR SPACES ARE TO BE CLOSED AND ESCUTCHEON PLATES AT HAND WASHING AREAS MUST BE SECURED. <br />38. TRAP FOR FLOOR DRAINS, FLOOR SINKS, OR HUB DRAINS ASSOCIATED WITH THE FOOD SERVICE AREAS AND NOT AS AN INDIRECT WASTE RECEPTOR SHALL BE <br />PROVIDED WITH A WATER SEAL OF AT LEAST 4" DEEP. <br />39. INSTALL VACUUM BREAKERS A MINIMUM OF 6" ABOVE THE FLOOD LEVEL RIM OF THE FIXTURE SERVED WITH NO SHUT-OFF DEVICES BEYOND THE DISCHARGE OF <br />THE VACUUM BREAKER. <br />40. ALL JOINTS, ANNULAR SPACES, OR OPENINGS INTO HOLLOW OR INACCESSIBLE AREAS ARE TO BE CLOSED TO 1/32" OR LESS FOR FOOD SERVICE AREAS. <br />INSTALL ALL FITTINGS AT FULL <br />LINE SIZE WITH CLEAR ACCESS <br />TO ALL ACCESS PORTS AND <br />FITTING HANDLE SWING <br />CLEARANCES. <br />PRESSURE <br />GAUGE <br />STRAINER <br />1" WATTS <br />25 UAB-DU-Z3 <br />W/INTEGRAL <br />STRAINER <br />1-1/4" ff't_ ; u) <br />WATTS 009 RPZ BACKFLOW- <br />COORDINATE WITH LOCAL WATER <br />UTILITY COMPANY REQUIREMENTS. <br />ROUTE DISCHARGE TO HUB DRAIN. <br />W IQ <br />SET AT 70# i} <br />Im <br />Ill <br />1-1/4" WATER SERVICE DETAIL <br />U <br />�I <br />r� <br />V <br />H <br />Zz <br />_Qom <br />C) <br />� C) <br />co aC110C) <br />Nco <br />W U) (o coajVwwcnLn <br />U (� V rn <br />♦` CwwDQ� <br />vl~TIUQ[=c� <br />co <br />� N <br />0 <br />LL <br />• <br />aIdofi6 <br />16009 <br />v <br />0 <br />n <br />0 <br />O <br />z <br />w <br />U) <br />z <br />w <br />U <br />J <br />Q <br />❑ <br />o: <br />O <br />J <br />U- <br />o= <br />Q <br />z <br />U) <br />D <br />CONTRACT DATE: <br />01.05.2016 <br />BUILDING TYPE: <br />N/A <br />PLAN VERSION: <br />DEC 2015 <br />SITE NUMBER: <br />N/A <br />STORE NUMBER: <br />N/A <br />SHELL BUILDOUT <br />5935 GALL BLVD <br />ZEPHYRHILLS, FL 33541 <br />REMODEL <br />PHASE 1 <br />SANITARY WASTE <br />AND <br />VENT <br />FLOOR PLANS <br />Pi mi <br />' �' �11 <br />WATER HAMMER ARRESTOR DETAIL <br />PLOT DATE: <br />