Laserfiche WebLink
-i _ 1 i1 _ 1 Il�d 11MIT, <br />r,nrr��i .nn n. Hold r- IA iL'.TA1 , r_ A[ M1 m <br />EXTEF <br />PLASI <br />FRAM <br />TEXTU <br />CEMEP <br />FINISH <br />FIBERGLASS SHINGLE INSTALLED AS PER <br />MANUFACTURER SPECIFICATIONS <br />TOM <br />­IGT_ ---- <br />FLR_---1-- <br />12 4' OFFRIDGE <br />51 <br />1/2 33 SH <br />Ci <br />I <br />6068 SGD <br />12 <br />�5 <br />25 SH 25 SH <br />CJ / WEEP <br />35 SH <br />REAR ELEVATION — B <br />SCALE: 1/4" = 1'-0" <br />EXTERIOR <br />PLASTER ON <br />FRAME <br />TEXTURED <br />CEMENTITIOUS <br />FINISH ON CMU <br />LEFT ELEVATION — B <br />SCALE: 1/4" = 1'-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior Plaster. <br />Installation of these materials shall be in compliance with ASTM <br />C926 and ASTM C1063, or ASTM C1787 and the provisions of <br />this code. <br />R703.7.1 Lath. <br />Lath and Lath attachments shall be of corrosion -resistant <br />materials. Expanded metal or woven wire lath shall be attached <br />with 1-1/2" long, 11 gage nails having <br />a 7/16" head, or 1-1/2" long, 16 gage staples, spaced in <br />accordance with ASTM C1063 or C1787, or as otherwise <br />approved. (Refer to sheet SN1 for the engineered method for <br />Lath attachment.) <br />Lathing Accessories <br />Attachments shall be of corrosion -resistant materials. <br />Wood Application: 16 Ga.x1-1/2" long (3/4%1" crown) staples @ <br />6" O.C. vertically/horizontally into the framing members. <br />Masonry Application: Concrete stub nail, 3/8" (10 mm) head dia. <br />min. @ 6" O.C. vertically/horizontally or compatible adhesives, <br />exterior gun -grade, construction adhesive with 1" dabs @ 6" O.C. <br />or in a semi -continuous bead between the solid plaster base and <br />the solid portion of the key attachment flange. <br />Control Joints: Install control joint lathing accessories in <br />conformance with C1063. Lath shall not be continuous through <br />control joints, but shall be stopped and tied at each side. <br />All accessories shall be in accordance with the latest ASTM <br />C1063 & ASTM C1861. <br />R703.7.2 Plaster. <br />Plastering with cement plaster shall be not less than three coats <br />where applied over any type of code -approved lath and shall be <br />not less than two coats where directly applied over masonry, <br />concrete, clay brick, stone, or tile. If the plaster surface is <br />completely covered by veneer or other facing material or is <br />completely concealed, plaster application need be only two coats, <br />provided total thickness is as set in Table R702.1(1). <br />Cement plaster shall be in accordance with ASTM C926 and <br />material shall be in accordance with one of the types listed in <br />R703.7.2. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed as required in Section <br />R703.2 and, where applied over wood -based sheathing, shall <br />include a water -resistive vapor -permeable barrier with a <br />performance at least equivalent to two layers of Grade D paper. <br />The individual layers shall be installed independently such that <br />each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to <br />the water -resistive barrier is directed between the layers. <br />R703.2 Water -Resistive Barrier. <br />One layer of No. 15 asphalt felt, free from holes and breaks, <br />complying with ASTM D226 for Type 1 felt or other approved <br />water -resistive barrier shall be applied over studs or sheathing of <br />all exterior walls. No. 15 asphalt felt shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 <br />inches. Where joints occur, felt shall be lapped not less than 6 <br />inches. Other approved materials shall be installed in accordance <br />with the water -resistive barrier manufacturer's installation <br />instructions. The No. 15 asphalt felt or other approved <br />water -resistive barrier material shall be continuous to the top of <br />walls and terminated at penetrations and building appendages in <br />a manner to meet the requirements of the exterior wall envelope <br />as described in Section R703.1. <br />R703.4 Flashing. <br />Approved metal flashing, vinyl flashing, self -adhered membranes <br />and mechanically attached flexible flashing shall be applied <br />shingle -fashion or in accordance with the manufacturer's <br />instructions. Metal flashing shall be corrosion resistant. <br />Fluid -applied membranes used as flashing shall be applied in <br />accordance with the manufacturer's instructions. All flashing shall <br />be applied in a manner to prevent the entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. <br />Self -adhered membranes used as flashing shall comply with <br />AAMA 711. All exterior fenestration products shall be sealed at <br />the juncture with the building wall with a sealant complying with <br />AAMA 800 or ASTM C920 Class 25 Grade NS or greater for <br />proper joint expansion and contraction, ASTM C1281, AAMA 812, <br />or other approved standard as appropriate for the type of sealant. <br />Fluid -applied membranes used as flashing in exterior walls shall <br />comply with AAMA 714. The flashing shall extend to the surface <br />of the exterior wall finish. <br />Approved flashings shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry construction with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersection. <br />• At Built-in gutters. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />REV. 09.24.21 <br />r o <br />C%A-- <br />o <br />X <br />00 <br />'A- <br />0 N <br />i" ,r0 ;=S <br />n00 <br />>>t7 <br />,.-W <br />i <br />i <br />cam: <br />ILL <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />U) <br />ro <br />_N Q <br />O M p N it <br />U <br />O N � J <br />m� <br />o�� <br />N a J LL <br />�nC? itLLa <br />to <br />M <br />rn <br />� (Nn v , a. <br />13LL <br />(O i� a w <br />CK Q <br />Z <br />Zz 0 <br />L <br />'1 19 <br />(0 _ <br />o O <br />7 (0 N (_O m O J <br />Z <br />LLW <br />r° c� <br />a <br />Z <br />Z X Ln O <br />N M <br />OUvJN <br />wv) <br />z N M <br />z $ <br />-Zo a <br />a <br />z <br />C7 `o <br />u <br />4 <br />N <br />Tom• <br />V <br />� g <br />0 <br />w s <br />l/1 <br />c N <br />U) <br />�r�E� <br />U <br />E <br />l0 p <br />_.... <br />zl� �• <br />Q V) <br />O <br />o <br />M <br />M <br />m <br />o <br />w <br />z <br />4 <br />c E <br />O <br />E <br />C <br />�o <br />o~ <br />� <br /><� <br />Z® <br />Da <br />v <br />Z <br />F— <br />_ <br />NO <br />xo <br />VO <br />d h <br />z <br />ao <br />'o <br />ii Z <br />0 <br />Q <br />Z <br />L <br />ra <br />cx <br />J <br />p <br />J <br />m C) <br />o <br />=. <br />�Z <br />U) <br />�m <br />W <br />a`�'i <br />iz <br />oa <br />2 <br />go <br />w <br />o <br />to <br />w� <br />XI0 <br />'O <br />a <br />� <br />za <br />0 ; <br />2O <br />= <br />` <br />>M <br />J <br />O <br />rn <br />m <br />O <br />L <br />L0 <br />C <br />r <br />Y <br />r�//�� <br />VJ <br />L� <br />m <br />O <br />O <br />Q <br />N <br />CV <br />N <br />r <br />ui <br />m <br />y <br />M <br />N <br />vi N <br />o <br />Z <br />Z <br />m <br />E T- <br />E <br />N <br />`m <br />c <br />c <br />a <br />U _J <br />Q p <br />JOB <br />NO: <br />22-02365 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />2.2 <br />