My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6313 Beverly Hills Dr
Zephyrhills
>
Building Department
>
Building Plans
>
6313 Beverly Hills Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 12:38:55 PM
Creation date
2/18/2025 3:25:42 PM
Metadata
Fields
Template:
Building Plans
Street #
6313
Location
Beverly Hills Dr
Contractor
Lennar
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
_I -_ I I__ I L_ __ <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided With a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />I� <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />771 <br />Nil <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />-� <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />�D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />P13 <br />PUSH BUTTON SWITCH (OPTIONAL) <br />DB <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />a <br />TELEVISION (OPTIONAL) <br />❑TV 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />►� <br />ELECTRIC METER <br />tL <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />C� J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />r J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />150A1200A INDOOR <br />PANEL CENTER <br />NEMA1 <br />150 AMP/ <br />200 AMP <br />MAIN <br />0 <br />200 amp <br />150 amp <br />copper to lights & outlets <br />copper to 20 amp ckts <br />2 copper to WH <br />3 copper to Dryer <br />or 4/0 SER Alu <br />UNDERGROUND Disconnect <br />POWER CO. FEED <br />INTERSYSTEM 4 Bare Cu Ground <br />BONDING #4 GROUNDING WIRE <br />TERMINATION PER WITH CODE APPROVED <br />NEC 17, 250.94 CLAMP PER 250.50 AND <br />250.52 OF NEC 17. <br />Typical 150-200 Amp Electrical Riser Diagram REV. 04.06.21 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER CO. <br />DEDICATED - <br />RECEPTACLE FOR <br />MICROWAVE RANG <br />HOOD PER SPECS <br />1.5" VTR III 3" VTR <br />III I� <br />I <br />I I <br />I I <br />i I <br />I/ <br />I \\ tl13" VTR <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />lI <br />I ti SWITCH FOR <br />O DISPOSAL <br />�I I <br />I I <br />J I <br />X LIC <br />F 7oI GFI <br />\ I'' <br />N I <br />I <br />GFI <br />1 I DWI <br />L <br />I \N1- 1 <br />ITCHEN <br />I— Iml-ii / <br />rs�z7►� 1[ Illltlll� <br />SPEC 3 & 4 KITCHEN <br />SCALE: Y4'=1'-0" <br />A/C PAD <br />DISC. WP <br />GFI <br />A <br />DEDICATED——` <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS <br />w w <br />W <br />Z J <br />�O:) <br />CoPZ <br />�UI=— <br />>OJ� <br />FI `1—DB & GFI TO <br />------- BE ALIGNED <br />VERTICALLY <br />I <br />I <br />COACH LIGHTS ZCOACH LIGHTS <br />OR PREWIRE AS / OR PREWIRE AS <br />PER SPECS / PER SPECS <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />I I � <br />I I I <br />I I I <br />I I I <br />I I <br />I I----------� <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />L— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — J <br />SECOND FLOOR ELECTRICAL PLAN <br />FIRST FLOOR ELECTRICAL PLAN - ELEV-B <br />ELEV-B <br />N <br />N <br />00 <br />a' O <br />y <br />C <br />O <br />w <br />x <br />U <br />0 <br />Q <br />j N <br />I❑ <br />ti5 <br />cA O O <br />` -3 <br />c L) <br />0LU <br />CV <br />CV <br />0 <br />CV <br />CV <br />CV <br />O <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />0 <br />0 <br />F- <br />o oME �u <br />V <br />- 0 <br />o m <br />� N 7k LL W <br />0 <br />N <br />n r a -a w a <br />M 0 u_ CL <br />Q <br />M J., Lt_ LLl u <br />r a <br />Z <br />0 <br />M <br />CI ° <br />0��� �o_j <br />in °' Q <br />= <br />ILW <br />a' Q a <br />N rNiZ Xto 0 <br />0 U� U) <br />Z <br />000 <br />CD <br />Z N M <br />0 <br />Z � N <br />Z o <br />Q <br />J — <br />U) <br />tV <br />h <br />z <br />v <br />�N <br />� <br />_ LL <br />w m <br />0 <br />w g <br />to <br />�NZD <br />� <br />w <br />I <br />0 <br />U)4 <br />481 <br />O <br />CD <br />w <br />M <br />O <br />Z <br />Z <br />< <br />a. E <br />� <br />=o <br />o. <br />w= <br />>� <br /><� <br />Z® <br />oa <br />OU <br />OU <br />Z <br />c <br />O <br />O <br />K U <br />a¢ <br />a <br />O <br />0< <br />ww <br />N <br />az <br />wE <br />i <br />CY <br />o <br />mo <br />Ott <br />Z <br />C!) J <br />m o <br />6 w <br />N <br />o< <br />Z Z <br />5-Zw <br />d <br />N <br />W <br />> <br />0 <br />Co <br />w <br />�I'o <br />Co <br />Q <br />of r <br />Z< <br />o <br />0 <br />C O <br />i <br />>M <br />C <br />d- <br />m <br />0 <br />L0 <br />M d' <br />r <br />VJ m <br />CN <br />C <br />O <br />L�n <br />N <br />Q <br />N <br />T <br />N <br />(D <br />m <br />w <br />� <br />N <br />iri N <br />a <br />Z <br />Z <br />E T_ <br />ui <br />ccE c <br />a <br />0 <br />v <br />v � <br />a 0 <br />c <br />JOB <br />NO: <br />22-02365 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.