My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6343 Beverly Hills Dr
Zephyrhills
>
Building Department
>
Building Plans
>
6343 Beverly Hills Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 1:16:44 PM
Creation date
2/18/2025 3:27:11 PM
Metadata
Fields
Template:
Building Plans
Street #
6343
Location
Beverly Hills Dr
Contractor
Lennar
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
II 11 111 1I-Pl_-- _ t - I <br />3/4" PLYWOOD <br />DECKING <br />FLOOR <br />SYSTEM <br />;I - <br />ITN <br />CONT. HANDRAIL <br />RETURN TO_ <br />A) WALL DETAIL. <br />SCALE: NTS <br />STAIR CALCULATIONS: <br />TOTAL RISE = 10'-0 3/4" <br />(16) RISERS AT 7 -9/16" <br />10" TREADS w/ 3/4" NOSING <br />42" KNEE WALL WITH <br />1 x8 CAP & CASING <br />USP MP3 CLIP EA. <br />STRINGER TO BEAM/ <br />FLOOR SYSTEM TYP. <br />16 ` <br />15 `\ 36" H. CONT. <br />14 GRASPABLE <br />13 CD RAILING <br />` I <br />M <br />12 \ I <br />`\ I <br />` I <br />11 1 off 1 <br />`\01I <br />10 <br />1x TREAD \` I <br />I �r <br />(TYP.) 9 \ 1 00 <br />8 MIS co <br />STORAGE <br />UNDER 7 - <br />STAIRS 6�vv <br />2x FRAMED 5 <br />WALL a��\ <br />1x RISERS <br />71 (TYP.) 3 <br />2 \ <br />2x FRAMED (3) 2x12 <br />WALL STRINGERS <br />2x4 #2 SYP. P.T. THRUST BLOCK <br />W/(2)- 1/4"x 3 1/2" TAPCONS @ <br />161111o.c. AND 3" FROM EA. END. <br />TYP. STAIR SECTION <br />L SEE PLAN FOR LANDING DEPTH <br />MIN. (3) 2x STUDS R <br />@ END OF LANDINC <br />BELOW HDR. BEAM <br />STANDARD (3) 2x1 <br />STRINGERS w/ <br />SIMPSON A35/USP <br />MP34 CLIP TO <br />FLOOR SYSTEM O <br />LANDING FRAMIN( <br />(2) 2x HDR. <br />REQ'D @ EN[ <br />LANDING FOF <br />STRINGERS - <br />CONNECT TC <br />1 <br />PLY SHEATHING OVER <br />LANDING ATTACHED PER <br />GENERAL FLOOR <br />CONSTRUCTION NOTES <br />2x8 #2 SYP JOISTS @ LANDING <br />@ 16"O.C. w/ SIMPSON A35/USP <br />MP34 OR LUS26 HANGER ON <br />EA. SIDE <br />MASONRY OR WOOD WALL, <br />SEE PLAN <br />2x8 #2 SYP (P.T. IF MASONRY <br />WALL) CONTINUOUS LEDGER <br />w/ (3) 16d NAILS @ 16" O.C. MAX. <br />TO EA. STUD. ((2) 1/4"X3 1/2" <br />TITENS @ 16" O.C. MAX. FOR <br />MASONRY WALL) <br />GENERAL LANDING FRAMING INFO. <br />SCALE: N.T.S. 9'-0" MAX LANDING LENGTH <br />42" KNEE <br />WALL WITH <br />1 x8 CAP & <br />CASING <br />fL <br />1 x8 CAP & <br />CASING <br />1 <br />TYP. @ D2 <br />CORNERS <br />6 = <br />H1 D2 <br />O <br />3 <br />D2 <br />SIM. W/ (1) <br />MSTAM36 <br />STRAPS @ <br />BASE <br />TUB/ SHWR <br />TILE TO 7' <br />A.F.F. <br />H1 6 N <br />D2 <br />O <br />DRYER VENT <br />THRU SIDE WALL- <br />) <br />>J <br />HANSON BOOR <br />@ 36" A.F.F. <br />WIRE SHELF <br />@ +54" A.F.F.-" <br />J <br />S6 <br />TYP. <br />U.N.O. <br />4�� <br />SIM. W/ (1) <br />MSTAM36 <br />STRAPS @ <br />BASE <br />140C <br />REV 10.1.20 CAB <br />EXTERIOR 2ND FLOOR <br />BEARING WALL SCHEDULE <br />HEIGHT <br />STUD <br />SPECIES <br />SPACING <br />SPF #2 <br />8'-0" <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />9'-0" <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />2x6 <br />SYP #2 <br />16" O.C. <br />' WHEN THE TOP OF WALL IS GREATER THAN 9'-0", THEN AT <br />EACH EXTERIOR CORNER WITHIN THE 4'-0" END ZONE, THE <br />STUDS WILL BE DOUBLE STUDS @ 16" O.C. OR SINGLE STUDS <br />@ 12" O.C.' <br />THIS IS ONLY USED WITH PLASTER OR STUCCO EXTERIOR <br />FINISH <br />WALL SHEATHING 15/32" EXPOSURE 1 OR EQUIVALENT. <br />REFER TO SHEATHING SCHEDULE FOR ATTACHMENTS- <br />r-------------------- <br />I <br />T-8" <br />I I <br />j H1 I <br />I 16 <br />0,16 <br />2 <br />J <br />O <br />125 <br />TYP. S6 <br />H <br />U.N.O. 25 <br />H <br />TB 60" X 36" <br />EGRESS* <br />EGRESS* <br />SHOWER <br />O <br />FIBERGLASS <br />SURROUND <br />MASTER <br />TP <br />-0t' -- <br />- 5-0 -, - <br />O <br />BEDROOM <br />,M - BA <br />8'-0" FLAT CLG. <br />�668 <br />CARPET <br />�2068 <br />- 4'-0" (FLAT, G. <br />BF , <br />T►LE <br />G.T. 00 <br />3'-6" <br />rn <br />15'-8' <br />- <br />4-SH <br />il <br />I <br />8t 0" FLAT CLG. <br />u) I CARPET -b <br />20684..E <br />IACCESS- > <br />L----- <br />----i- - <br />R&_L <br />s <br />p s s <br />BEDROOM 4 <br />-- - <br />-0 P <br />8'-0" FLAT CLG. <br />;n <br />CARPET <br />00 <br />E-0"-FLAT Ci G, - <br />'-6" o <br />TB <br />-- <br />1/2 WALL OR <br />RAILING PER SPECS <br />w <br />TECH CENTER <br />w <br />7-9" 5'-11"1. <br />2668 11'-4" <br />'k <br />2668 <br />CN <br />- <br />L---------- <br />BF <br />N. 6R I <br />15068 BF <br />D <br />TY I <br />1 1 14 1 12 11 10 9 8 7 6 5 4 <br />Irn <br />' LAUN <br />C---------- ------I� <br />8'-0" FLAT CLG-- <br />TILE <br />13'-11" T-10" <br />2652 <br />5-11" - ' <br />R&S <br />------ <br />I W <br />�, <br />4068 <br />00 s- t <br />to :?.. 5'-0�P, <br />BF <br />5'-10" <br />9'-52" <br />CD <br />cv <br />41 <br />iv <br />1 <br />1 <br />I <br />5068 I G.T. <br />- - 11'-6"T <br />_ <br />- - B 2 11'-2" - <br />- <br />v <br />1 <br />BEDROOM 3 <br />;06 BEDROOM 2 <br />8'-0" FLAT CLG. <br />I 8'-0" FLAT CLG. <br />CARPET <br />I CARPET <br />EGRESS*l <br />J <br />' <br />EGRESS* <br />I 9 H1 <br />I D2 <br />I 25 <br />I © <br />SH <br />9 <br />D2 22 <br />25 <br />39 © <br />H1 D1 <br />D1 <br />JAMB STUD OVER <br />I <br />I ENTRY TO BE <br />I <br />I CONNECTED DOWN <br />I <br />I PER DETAIL 6/D2 <br />5-10" <br />5'-10" <br />6-8" <br />6-8" <br />18'-8" 6'-4" <br />25'-0" <br />co <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H 1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2950 <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1/2" <br />Follow Q/S4. See Plan for <br />RAG <br />FLITCH PLATE <br />Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />'* SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />2x4 #2 SPF STUDS @ 16" <br />O.C. TYP. @ 2nd FLOOR <br />EXTERIOR WALLS <br />3 <br />D2 <br />SIM. W/ (1) <br />MSTAM36 <br />STRAPS @ <br />BASE <br />J <br />S6 <br />TYP. <br />U.N.O. <br />N kD)2 <br />A <br />H1 <br />3 <br />D2 <br />SIM. W/ (1) <br />MSTAM36 <br />STRAPS @ <br />BASE <br />2 <br />OPENING PRESSURES <br />ENCLOSED-EXPOSURE"C" <br />�A <br />+29.7 / -32.2 <br />© <br />+29.7 / -39.7 <br />O <br />+28.3 / -30.8 <br />() <br />+28.3 / -37.0 <br />�E <br />+26.6 / -29.1 <br />OF <br />+26.6 / -33.5 <br />GO <br />SEE SN SHEET OH SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +29.7 / -39.7 <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20 X 26 <br />181 X 25 <br />S.H. <br />13 <br />20X383 <br />18'X374 <br />S.H. <br />14 <br />20 X 50 5 <br />1812X 50 <br />S.H. <br />15 <br />20 X 63 <br />18' X 621 <br />S.H. <br />16 <br />20 X 72 <br />1812 X 713 <br />S.H. <br />1 H2 <br />27 1/4 X 26 <br />26 X 25 2 <br />S.H. <br />11-13 <br />271/4X3838 <br />26x374 <br />S.H. <br />1 H4 <br />27 J X 50 q <br />26 x 50 <br />S.H. <br />1 H5 <br />27 'X 63 <br />26 X 62 1/2 <br />S.H. <br />1 H6 <br />27 a X 72 <br />26 X 71 1/2 <br />S.H. <br />22 <br />37 X 26 <br />36 2 X 25 1/2 <br />S.H. <br />23 <br />37 4 X 38 J <br />36 2' X 37 3/4 <br />S.H. <br />24 <br />37 4 X 50 g <br />36 1 X 50 <br />S.H. <br />25 <br />37 4 X 63 <br />36 4 X 62 1/2 <br />S.H. <br />26 <br />37 4 X 72 <br />36 4 X 71 1/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />731 WIDE <br />S.H. <br />32 <br />54 X 26 <br />5212 X 25 <br />S.H. <br />33 <br />54 X 38 $ <br />52 � X 37 4 <br />S.H. <br />34 <br />54 X 50 <br />52 � X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 J X 621 <br />S.H. <br />36 <br />54 X 72 <br />52 21X 71 1 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />Stair and Railing General Notes <br />Stairway construction shall conform to the FBC Residential 7th Edition (2020) sections R311.7, R312 <br />and R302.7. <br />Riser height: <br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading <br />edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by <br />more than 3/8 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the <br />vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The <br />greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Winders: <br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the <br />foremost projection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread <br />depth of not less than 6 inches at any point within the clear width of the stair. <br />Nosings: <br />Nosings at treads, landings and floors of stairways shall have a radius of curvature at the nosing not greater than <br />9/16 inch or a bevel not exceeding '% inch. A nosing projection not less than 3/4 inch and not more than 11/4 <br />inches shall be provided on stairways. The greatest nosing projection shall not exceed the smallest nosing <br />projection by more than 3/8 inch within a stairway. <br />Handrails: <br />Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more <br />risers. Handrail height measured vertically from the sloped plane adjoining the tread nosing, or finish surface of <br />ramp slope, shall be not less than 34 inches and not more than 38 inches. Handrails for stairways shall be <br />continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly <br />above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety <br />terminals. Handrails adjacent to a wall shall have a space of not less than 11/2 inches between the wall and the <br />handrails. <br />Grip -size: <br />Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater <br />than 2 inches or provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />Guards: <br />Guards shall be provided for those portions of open -sided walking surfaces, including stairs, ramps and landings, <br />that are located more than 30 inches measured vertically to the floor or grade below at any point within 24 inches <br />horizontally to the edge of the open side. Required guards at open -sided walking surfaces, including stairs, <br />porches, balconies or landings, shall be not less than 36 inches in height as measured vertically above the <br />adjacent walking surface or the line connecting the leading edges of the treads. Required guards shall not have <br />openings from the walking surface to the required guard height that allow passage of a sphere 4 inches in <br />diameter. <br />Under -stair protection: <br />Enclosed space under stairs that is accessed by a door or access panel shall have walls, under -stair surface and <br />any soffits protected on the enclosed side with 1/2-inch gypsum board. <br />� SECOND FLOOR PLAN - ELEV-B <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic, crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />MASONRY HGT. @ 8'-8" A.F.F. <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO <br />UPLIFT CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />FIRST LIVING <br />728 S.F. <br />SECOND LIVING <br />1036 S.F. <br />TOTAL LIVING <br />1764 S.F. <br />LANAI <br />60 S.F. <br />GARAGE <br />379 S.F. <br />ENTRY <br />62 S.F. <br />TOTAL SQ. FT. <br />2265 S.F. <br />INSULATION REQ. <br />LOCATION <br />R-VALUE / TYPE <br />EXT CONC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 <br />R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 <br />R-19 KRAFT FACED <br />CONDITIONED CEILING <br />R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION <br />R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />-a <br />cl�a <br />nt <br />Q U <br />0- <br />co LL OL <br />'a c) +_ <br />Q <br />V (>3 CD M <br />c -0 Y <br />ll <br />- r � <br />H.. �• ri L'r! <br />�e�^ <br />.• <br />E <br />(a . O <br />UI <br />ry <br />• \ J cV` <br />r����j <br />•� <br />L;� <br />•.,t <br />w <br />`� J �-•ate ...+•J •'+•'-' <br />- <br />'\\� <br />', <br />�' <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />rn <br />H$ <br />00Q <br />E <br />O Cr) 804 N <br />N m-� <br />G <br />0 <br />ao ac �` wa <br />JLu <br />ILL a <br />M OV <br />QN <br />Y <br />� LLJ <br />Z <br />W of <br />m 5 <br />_ <br />6 0 <br />J <br />W <br />U) CP d a <br />Z <br />LL <br />00 a <br />N M Z X N 0 <br />t7 <br />pU��v�i <br />_ <br />W <br />❑❑❑ <br />Z N 0 <br />0 <br />z N <br />z � � <br />Ln <br />0 c <br />}1 <br />N LL <br />1 <br />19 <br />•rJ <br />� 'm <br />oc� <br />�N <br />�. <br />U <br />sf. <br />E <br />- _ E <br />WIG <br />N C <br />Q <br />N Ol <br />o <br />w <br />Mwa <br />Z <br />� <br />J <br />u <br />ce E <br />w� <br />Zs <br />°a <br />Eco <br />Z <br />♦- `0 <br />N <br />pa <br />00 <br />°ZZZZ <br />d i <br />< i <br />J <br />m 0 <br />3 <br />C <br />C <br />oY <br />h <br />0 <br />OZ <br />Z <br />>Z <br />Z <br />__ <br />m <br />N <br />N <br />FW <br />oa <br />ZZ <br />50 <br />Q <br />LL <br />a <br />�Z <br />W <br />U <br />ao <br />s <br />o� <br />C> <br />coa3: <br />waza <br />�° <br />a <br />o e-I <br />-117 <br />>LO <br />J <br />m <br />0 <br />� <br />T <br />CID <br />�T..��.. <br />ooI <br />T <br />Cf <br />T <br />U o <br />~ <br />O <br />� <br />C:) <br />N <br />In <br />T <br />Q <br />T <br />N <br />6 <br />co <br />T <br />N <br />iri 04 <br />o <br />Z <br />Z <br />E T <br />�' <br />m <br />C cc <br />0- <br />U J <br />JOB <br />NO: <br />22-02361 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />1.2 <br />S C( L <br />A <br />0i <br />
The URL can be used to link to this page
Your browser does not support the video tag.