My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6343 Beverly Hills Dr
Zephyrhills
>
Building Department
>
Building Plans
>
6343 Beverly Hills Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 1:16:44 PM
Creation date
2/18/2025 3:27:11 PM
Metadata
Fields
Template:
Building Plans
Street #
6343
Location
Beverly Hills Dr
Contractor
Lennar
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I L-- ! 1 1 --t <br />I ' III 1 III <br />FIBEREGLASS SHINLGE INSTALLED <br />AS PER MANUFACTURER <br />SPECIFICATIONS <br />EXTERIOR <br />PLASTER ON <br />FRAME----,_ <br />-1 W <br />00 <br />FLASHING <br />2ND FIN _ <br />FLR <br />L T.O.M. _ <br />00 <br />00 <br />EXTERIOR <br />PLASTER ON <br />FRAME- <br />12 <br />5.0F <br />' -------------------- <br />-All ---------------- <br />------r t— -- <br />HDR. — <br />TEXTURED � ! '�-�I �- � �., , = <br />CEMENTITIOUS <br />00 <br />FINISH ON <br />�o CMU(TYP) <br />F-1 E] <br />FIN FLR <br />rt -- <br />--- —a <br />FRONT ELEVATION - B <br />SCALE: 1/4" = V-0" <br />1 <br />RAISED BANDS OR FOAM <br />PER COMMUNITY <br />SPECIFICATIONS <br />SCORED <br />STUCCO TYP. <br />12 CJ 25-SH CJ <br />I 4.0� <br />— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — <br />I -IN I-LH <br />-- -- -------- I CJ/WEEP <br />12 <br />14.0 <br />v <br />C <br />f; <br />v <br />v <br />25-SH 25-SH <br />R--------- ---------------- -- -------------------------f-------- — — — — — — — — — — -- ---- <br />TEXTURED <br />CEMENTITIOUS <br />FINISH ON <br />CMU (TYP) <br />RIGHT ELEVATION - B <br />SCALE: 1/4" = V-0" <br />DETAIL <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior Plaster. <br />Installation of these materials shall be in compliance with ASTM <br />C926 and ASTM C1063, or ASTM C1787 and the provisions of <br />this code. <br />R703.7.1 Lath. <br />Lath and Lath attachments shall be of corrosion -resistant <br />materials. Expanded metal or woven wire lath shall be attached <br />with 1-1/2" long, 11 gage nails having <br />a 7/16" head, or 1-1/2" long, 16 gage staples, spaced in <br />accordance with ASTM C1063 or C1787, or as otherwise <br />approved. (Refer to sheet SN1 for the engineered method for <br />Lath attachment.) <br />Lathing Accessories <br />Attachments shall be of corrosion -resistant materials. <br />Wood Application: 16 Ga.x1-1/2" long (3/4%1" crown) staples @ <br />6" O.C. vertically/horizontally into the framing members. <br />Masonry Application: Concrete stub nail, 3/8" (10 mm) head dia. <br />min. @ 6" O.C. vertically/horizontally or compatible adhesives, <br />exterior gun -grade, construction adhesive with 1" dabs @ 6" 0. C. <br />or in a semi -continuous bead between the solid plaster base and <br />the solid portion of the key attachment flange. <br />Control Joints: Install control joint lathing accessories in <br />conformance with C1063. Lath shall not be continuous through <br />control joints, but shall be stopped and tied at each side. <br />All accessories shall be in accordance with the latest ASTM <br />C1063 & ASTM C1861. <br />R703.7.2 Plaster. <br />Plastering with cement plaster shall be not less than three coats <br />where applied over any type of code -approved lath and shall be <br />not less than two coats where directly applied over masonry, <br />concrete, clay brick, stone, or tile. If the plaster surface is <br />completely covered by veneer or other facing material or is <br />completely concealed, plaster application need be only two coats, <br />provided total thickness is as set in Table R702.1(1). <br />Cement plaster shall be in accordance with ASTM C926 and <br />material shall be in accordance with one of the types listed in <br />R703.7.2. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed as required in Section <br />R703.2 and, where applied over wood -based sheathing, shall <br />include a water -resistive vapor -permeable barrier with a <br />performance at least equivalent to two layers of Grade D paper. <br />The individual layers shall be installed independently such that <br />each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to <br />the water -resistive barrier is directed between the layers. <br />R703.2 Water -Resistive Barrier. <br />One layer of No. 15 asphalt felt, free from holes and breaks, <br />complying with ASTM D226 for Type 1 felt or other approved <br />water -resistive barrier shall be applied over studs or sheathing of <br />all exterior walls. No. 15 asphalt felt shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 <br />inches. Where joints occur, felt shall be lapped not less than 6 <br />inches. Other approved materials shall be installed in accordance <br />with the water -resistive barrier manufacturer's installation <br />instructions. The No. 15 asphalt felt or other approved <br />water -resistive barrier material shall be continuous to the top of <br />walls and terminated at penetrations and building appendages in <br />a manner to meet the requirements of the exterior wall envelope <br />as described in Section R703.1. <br />R703.4 Flashing. <br />Approved metal flashing, vinyl flashing, self -adhered membranes <br />and mechanically attached flexible flashing shall be applied <br />shingle -fashion or in accordance with the manufacturer's <br />instructions. Metal flashing shall be corrosion resistant. <br />Fluid -applied membranes used as flashing shall be applied in <br />accordance with the manufacturer's instructions. All flashing shall <br />be applied in a manner to prevent the entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. <br />Self -adhered membranes used as flashing shall comply with <br />AAMA 711. All exterior fenestration products shall be sealed at <br />the juncture with the building wall with a sealant complying with <br />AAMA 800 or ASTM C920 Class 25 Grade NS or greater for <br />proper joint expansion and contraction, ASTM C1281, AAMA 812, <br />or other approved standard as appropriate for the type of sealant. <br />Fluid -applied membranes used as flashing in exterior walls shall <br />comply with AAMA 714. The flashing shall extend to the surface <br />of the exterior wall finish. <br />Approved flashings shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry construction with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersection. <br />• At Built-in gutters. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />REV. 09.24.21 <br />N <br />(U L O <br />o <br />� O <br />=�- <br />C*4 <br />TN <br />,L7t— <br />C:J-C <br />Q <br />Q <br />7 Y <br />U3 < <br />_ E <br />E c <br />o 0 <br />-` <br />a FLU <br />C-A <br />ae <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />tl! <br />$ <br />a <br />o E Co <br />C) a) m at <br />N <br />C) N � J <br />N O LL <br />Q <br />O C � J <br />rp N it LL W <br />W <br />� n P W a <br />v LL a x <br />C-) <br />a W o <br />Z <br />-JLL <br />06 <br />0o <br />tmC, <br />a o <br />7 ratio co O <br />W <br />a <br />a <br />Z <br />LL <br />00 d a <br />s <br />N MZ cr rn O <br />Z <br />o0 03� <br />W <br />❑0❑ <br />O <br />Z � O <br />z o <br />Q Z!,E3 <br />z <br />(D o <br />Q) <br />�N <br />f6 <br />LL R <br />O <br />N <br />w o <br />L N <br />un <br />U <br />�- e <br />U o' <br />U) <br />° <br />•Q <br />C <br />m <br />C:,w <br />CID <br />co <br />J <br />2 <br />L <br />Z <br />4 <br />fd E <br />Q o <br />O <br />E <br />wz <br />_® <br />oa <br />—CL <br />2� <br />UO <br />¢ <br />00 <br />0a <br />Z <br />O E <br />N ru <br />o <br />¢ o <br />o <br />Z <br />�J <br />ci <br />y <br />mo <br />80 <br />Z <br />Z <br />_ <br />0 <br />°o< <br />Z <br />50 <br />O <br />W <br />T <br />U <br />JW <br />J <br />o <br />wa <br />a <br />��_ <br />V <br />za <br />o3 <br />0 O <br />= <br />'L <br />J <br />O <br />ai <br />rn <br />m <br />0 <br />L <br />T <br />CID <br />�T} <br />U) m <br />CO <br />N <br />O <br />N <br />Ln <br />T <br />Q <br />T <br />N <br />ui <br />w <br />N <br />o <br />m <br />T <br />ii N <br />Z <br />Z <br />c <br />E T <br />E <br />�' <br />m <br />C <br />d <br />U -1 <br />Q p <br />c <br />JOB <br />NO: <br />22-02361 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />2.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.