Laserfiche WebLink
i 3 .I 1 I 1. ,I.I IIA ,i ...I "III, - <br />1 '! <br />Software Version .1.. <br />r nCOMcheck <br />4/ <br />Interior Lighting <br />Compliance Certificate <br />Project Information <br />Energy Code: <br />90.1 (2016) Standard <br />Project Title; <br />Houndstown <br />Project Type: <br />Addition <br />Construction Site: <br />Owner/Agent: <br />Designer/Contractor: <br />6440 Fort King <br />Don Penn PE <br />Zephyrhills, FL <br />33542 <br />Don Penn Consulting Engineer <br />1301 Solana Blvd <br />Bldg 1/Suite 1420 <br />Westlake, TX 76262 <br />Allowed Interior Lighting Power <br />A <br />B <br />C <br />D <br />Area Category <br />Floor Area <br />Allowed <br />Allowed Watts <br />(ft2) <br />Watts 1 ft2 <br />(B X C) <br />1-Salon (Retail:SalesArea) <br />5690 <br />1,22 <br />6942 <br />Total Allowed Watts = <br />6942 <br />Proposed Interior Lighting Power <br />A <br />B <br />C <br />D <br />E <br />Fixture ID : Description I Lamp J Wattage Per Lamp / Ballast <br />Lamps/ <br /># of <br />Fixture <br />(C X D) <br />Fixture <br />Fixtures <br />Watt. <br />I <br />1-Salon (Retaii:Sales Area) <br />. <br />LED 3: A: Existing Lt: Other: <br />1 <br />53 <br />26 <br />1378 <br />- <br />LED 1: B: 2'x4' Troffer: Other: <br />1 <br />9 <br />48 <br />432 <br />1. <br />LED 2: C: Wall Sconce: Other: <br />1 <br />14 <br />26 <br />350 <br />LED 4: D: EX 8 linear: Other: <br />1 <br />7 <br />36 <br />252 <br />Incandescent 1: X: Emergenc light: Other: <br />1 <br />3 <br />5 <br />15 <br />Compact Fluorescent 3: X1: Exit: Other: Electronic: <br />1 <br />3 <br />5 <br />15 <br />Total Proposed Watts = 2442 <br />Interior Lighting Compliance Statement <br />Compliance Statement., The proposed interior lighting design represented in this document is consistent with the building plans <br />specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been <br />designed to meet the 90.1 (2016) Standard requirements in CO�i� <br />1.5.4 and to comply with any applicable <br />mandatory requirements listed in the Inspection Checklist. <br />Don Penn, P.E. na /1 A /9n29 <br />Name - Title Signature Date <br />Project Title: Houndstown <br />Data filename: E:\2022 Jabs\Houndstown\Zephyr Hills FL\Zephyr Compliance.cck <br />1 iH3 h Im act (Tier 1} 2=Medium im act Tier 2 3 Low Impact aci Tier 3 <br />COMcheck r4 Version 4.1.5. <br />8/0' 6 <br />Mechanical Compliance Certificate <br />Project Information <br />Energy Code: 90.1 (2016) Standard <br />Project Title: Houndstown <br />Location: Zephyrhills, Florida <br />Climate Zone: 2a <br />Project Type: Addition <br />Construction Site: Owner/Agent: Designer/Contractor: <br />6440 Fort King Don Penn PE <br />Zephyrhills, FL 33542 Don Penn Consulting Engineer <br />1301 Solana Blvd <br />Bldg 1/Suite 1420 <br />Westlake, TX 76262 <br />Mechanical Systems List <br />Quantity System Type 8r Description <br />1 HVAC System 1 (Single Zone): <br />Heating: 1 each - Duct Furnace, Electric, Capacity = 34 kBtu/h <br />No minimum efficiency requirement applies <br />Cooling: 1 each - Split System, Capacity = 60 kBtu/h, Air -Cooled Condenser, Air Economizer <br />Proposed Efficiency =13.00 SEER, Required Efficiency: 13.00 SEER <br />Fan System: None <br />1 HVAC System 2 (Single Zone): <br />Heating: 1 each - Duct Furnace, Electric, Capacity = 34 kBtu/h <br />No minimum efficiency requirement applies <br />Cooling: 1 each - Split System, Capacity= 60 kBtulh, Air -Cooled Condenser, Air Economizer <br />Proposed Efficiency = 13.00 SEER, Required Efficiency: 13.00 SEER <br />Fan System: None <br />1 HVAC System 3 (Single Zone): <br />Heating: 1 each - Duct Furnace, Electric, Capacity = 34 kBtulh <br />No minimum efficiency requirement applies <br />Cooling: 1 each - Split System, Capacity = 36 kBtu/h, Air -Cooled Condenser <br />Proposed Efficiency = 13.00 SEER, Required Efficiency: 13.00 SEER <br />Fan System: None <br />1 Water Heater 1: <br />Gas Storage Water Heater, Capacity: 30 gallons, Input Rating: 90 kBtu/h <br />Proposed Efficiency: 80.00 % Et, Required Efficiency: 80.00 % Et <br />Mechanical Compliance Statement <br />Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, <br />specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been <br />designed to meet the 90.1 (2016) Standard requirements in COMcheck sion 4.1.5.4 and to comply with any applicable <br />mandatory requirements listed in the Inspection Checklist. <br />Don Penn, P.E. 03/18/2022 <br />Name - Title Signature Date <br />Report date: 03/18/22 Project Title: Houndstown Report date: 03118/22 <br />Page 1 0 13 Data fil na e: E: 2022 o s H n t h it r li n k P f f e m \ b ou ds own e r Hills FL\Zephyr h Com a ce.cc Page 2 0 13 <br />\ !Z 1 9 I 1 P Y p Y P 9 <br />Project Title: Houndstown Report date: 03118/22 <br />Data filename: E:\2022 Jobs\Houndstown\Zephyr Hills FL\Zephyr Compliance.cck Page 6 of 13 <br />I Eott s i3. <br />MIM', <br />real ,Y# ,. K�f� , , •' . .§. i'59 <br />::: i ssrrs <br />�__ <br />.:. <br />r4 :A Efh3€Y :. i lk , , , ..,, z <br />I€a fA <br />11­i4§ <br />,,..,.. ..., <br />6,4.3'si.2 <br />:Thermostatic controls have a 5 °F <br />ZComplies <br />Requirement will be met. <br />iIFUP <br />ndeadband, <br />❑Does Not <br />i <br />I <br />❑Not Observable <br />❑Not Applicable <br />, i <br />f.R.3.2 <br />_ __ ......... <br />Temperature controls have setpoint <br />MComplies <br />........ ........ _........... ......... _.............. <br />Requirement will be met. <br />(F!20ja <br />overlap restrictions, <br />❑Does Not <br />❑Not Observable <br />❑Not Applicable <br />i <br />6 4 33 1 <br />........ .. ........ <br />HVAC systems equipped with at least <br />... ................... <br />:MComplies <br />....I ...... .......................... ........... ...................................................... <br />Requirement will be met. <br />i(FI21j3 <br />`:one automatic shutdown control <br />i❑Does Not <br />j <br />❑Not Observable <br />° <br />I <br />1.1.❑Not <br />Applicable <br />; <br />„a, <br />6 4,3,3 2 <br />_..._...._.......,___._......_.... _ <br />•Setback controls allow automatic <br />_,,.__, _ ,,,.. <br />MComplies <br />__....__.._. _. _.___,.._ ............_ _..__.._ . _. __ <br />Requirement will be met. <br />; <br />restart and temporary operation as <br />❑Does Not <br />ifFI22] <br />required for maintenance. <br />❑Not Observable <br />❑Not Applicable <br />•4.3,12 <br />..._ - <br />Air economizer has a fault detection <br />❑Complies <br />- - --.-- <br />Exception: Requirement does not apply. <br />[F120{1j3 <br />'1. and diagnostics (FDD) system (see <br />❑Does Not <br />details for configuration and <br />❑Not Observable <br />;operational requirements). <br />MNot Applicable <br />16.4,3;22 <br />................I..................._..... <br />`Air economizer has a fault detection <br />...... . .... <br />❑Complies <br />..... I. ..... ... .._.............. ......... <br />:Exception: Requirement does not apply, <br />ICFl200j3 <br />:and diagnostics (FDD) system (see <br />❑Does Not <br />: <br />! <br />i <br />details for configuration and <br />❑Not Observable <br />operational requirements). <br />MNot Applicable <br />„ <br />64,35 <br />_,... _................................. ---- <br />When humidification and <br />--- -----.. <br />MComplies <br />.. ---- ----... ... .... _ _ ---------- <br />Requirement will be met. I <br />;[Fl61 <br />dehumidification are provided to a <br />❑Does Not <br />zone, simultaneous operation is <br />Observable <br />prohibited. Humidity control prohibits <br />:❑Not <br />❑Not Applicable <br />he use of fossil fuel or electricity to <br />produce RH > 30% in the warmest <br />I <br />( <br />!zone humidified and RH < 60% in the <br />3 <br />g,,, <br />:coldest zone dehumidified. <br />............ .. <br />...... ........ <br />..... ...... ....... .. ............................ .................................................. <br />6 7 211 <br />Furnished HVAC as built drawings <br />MComplies <br />Requirement will be met. <br />;[FIn- <br />submitted within 90 days of system <br />❑Does Not <br />.acceptance. <br />❑Not Observable:I <br />€- <br />g <br />❑Not Applicable <br />�„ „ <br />6 7 2 2 <br />Furnished O&M manuals for HVAC <br />MComplies <br />--- ........ -................................ <br />Requirement will be met. <br />([FI8]'f <br />systems within 90 days of system <br />❑Does Not <br />i <br />acceptance, <br />❑Not Observable <br />I <br />❑Not Applicable <br />: <br />6.7.2.3 <br />___...___ __.__._.__ __.____ ...._.. <br />An air and/or hydronic system <br />__ __.........:. <br />MComplies <br />. _ .. --.- -._ ---.- ..__-_------.-- .. .. ---- ................................ <br />Requirement will be met. ' <br />[FI9)1 <br />balancing report is provided for HVAC❑Does <br />Not <br />systems serving zones >5,000 ft2 of <br />Not Observable <br />l . <br />conditioned area. <br />: 0 Applicable <br />I <br />i 6.7.2.4 <br />.................... . ........ .. ......... <br />HVAC control systems have been <br />. ...._Nat .._ <br />MComplies <br />....... _. ...... ._..... ....... -... ....... .......-_._ ....... ....... ........ I'll ...... ........ ....... -....... .....__........ .........................._........... <br />Requirement will be met. <br />[FI10]1 <br />.tested to ensure proper operation, <br />❑Does Not <br />calibration and adjustment of controls. <br />. <br />❑Not Observable' <br />❑Not Applicable <br />i7,4,43 <br />..... ........... .._............... ...... ........ ....--- ...... <br />Public lavatory faucet water <br />..... , , -- <br />MComplies <br />------ ------.. -- ------- -------- -------- <br />: Requirement will be met. <br />£[FI -11. <br />,temperature <=110°F. <br />❑Does Not <br />❑Nat Observable <br />❑Not Applicable <br />1 .H3gh Impact (Tier 1} <br />----- - <br />2 Medium Impact (Tier 2) 3 <.Low Impact (Tier 3) <br />Project Title: <br />Houndstown <br />Report date: 03/18/22 <br />Data filename: EA2022 jobs\Houndstown\Zephyr <br />Hills FL\Zephyr Compliance.cck <br />Page 11 of 13 <br />---- ------------ : <br />1 High Impact (Tier 1) 2.j; Medium Impact (Tier 2) 3 j Low Impact (Tier, 3j - <br />Project Title: Houndstown Report date: 03/18/22 <br />Data filename: EA2022 Jobs\Houndstown\Zephyr Hills FL\Zephyr Compliance.cck Page 7 of 13 <br />.e, <br />i._ e tsora ! <br />.,,, <br />) <br /><. <br />Sinai ins action <br />Corr€ lies <br />Ir <br />crmm gists sxtioa tfoxta. <br />1A p <br />. lie„ _ <br />W„ __ ...._.... W _ <br />j __. , _ , .....__. <br />8 7 1 <br />J(FI :6 <br />Furnished as -built drawings for <br />'electric power systems within 30 days <br />MComplies <br />'❑Does Not <br />.Requirement will be met. I <br />of system acceptance. <br />❑Not Observable <br />I <br />i <br />❑Not Applicable <br />_ <br />8 7.2 <br />-_ ..._ _..- _ _... <br />Furnished O&M instructions for <br />..._ _-- <br />MComplies <br />-----_.-- ------_-...__............_ _ <br />Requirement will be met. j <br />(F117]3 <br />systems and equipment to the <br />❑Does Not <br />building owner or designated <br />❑Not Observable, <br />j <br />'( <br />representative. <br />❑Not Applicable <br />9.2,2.3 <br />Interior installed lamp and fixture <br />:MComplies <br />See the In terior Lighting fixture schedule for values. <br />[Fi18]1 <br />' lighting power is consistent with what <br />`❑Does Not <br />i <br />is shown on the approved lighting <br />�❑Not Observable; <br />I <br />i <br />plans, demonstrating proposed watts <br />:are <br />❑Not Applicable <br />I <br />I <br />less than ore equal to allowed <br />q <br /><__________ <br />_.....:watts.. <br />9.4.4 <br />_. _..._..� <br />At least 75% of all permanently <br />______. <br />❑Complies <br />_..... _______. _ _, _. ___ _.__....... __ _. <br />Exception: Requirement does not apply. <br />[FI2011 <br />installed lighting fixtures in dwelling <br />;❑Does Not <br />units have >= 55 Im/W efficacy or a <br />[]Not Observable: <br />>= 45 Im/W total luminaire efficacy. <br />ZNotApplicable <br />s <br />_... _........_. <br />20 4 3 Elevators are designed with the <br />__._ <br />❑Complies <br />.__-._......_.... _.,_. <br />Exception: Requirement does not apply. <br />FF1�42 <br />proper lighting, ventilation power, and <br />❑Does Not <br />I <br />;standby made. <br />i% ,11111 <br />;❑Nat observable <br />I <br />I : <br />MNot Applicable <br />i <br />T 4 3 <br />___ _........._._ _.._ _ -__.- � ._. _._ <br />First 8 ft of outlet in <br />_._..__._.......__ ._....: <br />MComplies <br />_-_-______ _ __...._.__....__._.___..__........._............ ._..... _ ._._...___...._...._..-__; <br />' Requirement will be met. I <br />Cix]451z <br />%piping <br />nonrecirculating storage system, or <br />❑Does Not <br />; <br />branch piping connected to ' <br />❑Nat observable <br />M.�1I :l., :�,,I <br />�",­�",:��", ,.''.':,,.:,�"",i:I�::�::�,-::'::,�::::,',::�*,':-.,,*, <br />recirculated, heat traced, or <br />impredance heated piping is <br />❑Not Applicable <br />j' <br />insulated. <br />__._ _ ___f <br />Additional Comments/Assumptions: <br />---- -U --- ---- . - - - ..... ......... _ .., <br />1 High Impact (Tier 1) 2;,Medium Impact (Tier 2) � j,Low Impact {Tier,3) <br />Project Title: Houndstown <br />Data filename: E:\2022 Jobs\Houndstown\Zephyr Hills FL\Zephyr Compliance.cck <br />Report date: 03/18122 <br />Page 12 of 13 <br />Software Version ... <br />6COMcheck <br />�( Inspection <br />Checklist <br />Energy Code: 90.1 (2016) Standard <br />Requirements: 100.0% were addressed directly in the COMcheck software <br />Text in the "Comments/Assumptions" column <br />is provided by the user in the COMcheck Requirements screen. For each <br />requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception <br />is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. <br />e �< <br />E >Eri.$tE9EY . , f „ ,.. . <br />Plan e,v. <br />$£7°§ ti € 4AkikYY'e� 't Aa tirttlSt[$Si£+ 3 <br />to iQ ,....__.' <br />4.2.2, Plans, specifications, and/or <br />®Complies .Requirement will be met. <br />16.4.4.2.1, calculations provide all information <br />❑Does Not <br />E6.7.2 with which compliance can be <br />[PR2]1 determined for the mechanical <br />❑Not Observable <br />I systems and equipment and <br />❑Not Applicable i <br />document where exceptions to the <br />i standard are claimed. Load <br />calculations per acceptable <br />engineering standards and <br />handbooks. <br />-................................. ..- ------ - -_.... <br />4,2.2, . plans specifications, and/or <br />--- -.----- . - -- ----- ------------- ----- - ---_...._.. <br />®Complies :Requirement will be met. <br />l7.7,1, calculations provide all information <br />jQDoes Not <br />[10,4.2 with which compliance can be <br />❑Not Observable' <br />1[PR311 determined for the service water <br />`• <br />❑Not Applicable <br />i heating systems and equipment and <br />;document where exceptions to the <br />i standard are claimed. Hot water <br />system sized per manufacturer's <br />sizing guide. <br />- --- -- ----- ----- <br />r422 : Plans, specifications, and/or <br />------- ---- - ----- ------ ------ ---- ------ ------_ <br />®Complies :Requirement will be met. <br />$4 1.i calculations provide ail information <br />❑Does Not <br />EB 4 1,2 with which compliance can be <br />Eft 7 -11 <br />determined for the electrical systems <br />! <br />❑Not Observable' <br />["A61 and equipment and document where <br />:❑Not Applicable <br />I -1 exceptions are claimed. Feeder <br />connectors sized in accordance with <br />approved plans and branch circuits <br />_ sized for maximum drop of 3`Y". <br />€4,2.2, Plans specifications, and/or <br />ZComplies :Requirement will be met. <br />9.4.3, 9 7 !calculations provide all information <br />El Does Not <br />[PR4]1 with which compliance can be <br />❑Not Observable <br />:determined for the interior lighting <br />and electrical systems and equipment <br />❑Not Applicable j <br />and document where exceptions to <br />Ej <br />the standard are claimed. Information <br />provided should include interior <br />, lighting power calculations, wattage of; <br />I ;bulbs and ballasts, transformers and <br />i control devices. <br />_ _,_ <br />6.. <br />_.,__ _...._._ _ ____ __ _______._..,.,.,. <br />I[PR5]i systems commissioning included on <br />❑Does Not 1 <br />I I the plans or specifications for projects <br />❑Not Observable <br />>=50,000 ft2. <br />j ; <br />- - _ ___.__,._.___.-_-_ - _ <br />❑Not Applicables <br />_.__._.__,_____...__....._...._ _ _._ _ <br />Additional Comments/Assumptions: <br />r-,_....................._.._._._.,.______ <br />I 1 iH3gh Impact (T3er 1)iii <br />..., ._.___.._........--____._._ ..._.........�_....... ; <br />'Medium Impact (Tier Z) T 3 ;Low Impact (Tier 3) <br />Project Title: Houndstown <br />Report date: 03/18/22 <br />Data filename: EA2022 Jobs\Houndstown\Zephyr Hills <br />FL\Zephyr Compliance.cck Page 3 of 13 <br />II :..- -- .------ ---- - <br />- ------ - <br />I :High impact (T3er 1) 2 j�Med3um Impact (Tier 2) , 3 `/Low Impact (Tier 3) <br />Project Title: Houndstown Report date: 03118/22 <br />Data filename: EA2022 Jobs\Houndstown\Zephyr Hills FL\Zephyr Compliance.cck Page 8 of 13 <br />i6;4 7 'Freeze protection and snow/ice xComplies ; Requirement will be met. <br />UP09js :melting system sensors for future i❑Does Not <br />connection to controls. <br />i -Not Observable <br />❑Not Applicable <br />Additional Comments/Assumptions: <br />_ -._ ....,..._.,_._..__ ________. _---_..__ _______ <br />1 H1 h Im act Ti-'Ti-). Medium im act Tier 2 Low Im act Tier 3 <br />( ( ) ( ) <br />9 P ) 1 P P <br />Project Title: Houndstown Report date: 03/18/22 <br />Data filename: E:\2022jobs\Houndstown\Zephyr Hills FL\Zephyr Compliance.cck Page 4 of 13 <br />Additional Comments/Assumptions: <br />_......._ _.... .................................. ...... <br />1 Hi h Impact Tier 1 2 Medium Im act Tier 2 3 Low Im act Tier 3 <br />(( 9 P ( ) P ( ) P ( ) <br />L_ _..__..............................._.1 _. ____........_ <br />Project Title; Houndstown Report date: 03/18/22 <br />Data filename: E:\2022jobslHoundstown\Zelphyr Hills FL\Zephyr Compliance.cck Page 9 of 13 <br />Additional Comments/Assumptions: <br />_.___ _..... _ __ __.___........._ _.._..... __._._ _ _____ _.__......,_._...._.._...._.......__..._....,...,_......_ __, <br />1 High impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low impact (Tier 3) <br />Project Title: Houndstown Report date: 03118122 <br />Data filename: EA2022 jobs\Houndstown\Zephyr Hills FL\Zephyr Compliance.cck Page 5 of 13 <br />eckisx <br />F <br />B4sg fp €trtaf ItrsI'llpetitrt orpfiet <br />11 .11 <br />Ceras#n/Asulttpts <br />_, <br />i 4 2 <br />_: ,_. ,._ _. _....... <br />'At least 50% of all 125 volt 15- and <br />MComplies <br />_......, ..._.,..___,_......._,.....,._INA_ .__ ,. _._._._11 _. <br />Exception: Space type is not private office, open office, or <br />€E) I ,, <br />.20-Amp receptacles are controlled by <br />❑Does Not <br />computer classroom: <br />a <br />?an automatic control device. <br />❑Not Observable <br />a <br />❑Not Applicable <br />!�11.111 New buildings have electrical energy❑Complies <br />Exception: Buildings 25,000 ft2. <br />[EL111 <br />' use measurement devices installed. <br />❑Does Not <br />Where tenant spaces exist, each <br />❑Not Observable <br />tenant is monitored separately, in <br />buildings with a digital control system <br />®Not Applicable : <br />I <br />the energy use is transmitted to to <br />I <br />�eontrol system and displayed <br />[ <br />£ <br />9raphicallY. <br />_.. - <br />9 41 <br />:.Automatic control requirements <br />®Complies <br />Requirement will be met. II <br />i[ELljz <br />prescribed in Table 9,6.1, for the <br />❑Does Not <br />' <br />appropriate space type, are installed. <br />Mandatory lighting <br />-]Not Observable; <br />E <br />controls (labeled <br />❑Not Applicable i <br />i <br />as'REQ') and optional choice controls <br />1. (labeled as 'ADD/' and 'ADD2`) are <br />i <br />implemented. <br />? <br />41.: <br />........ ........ ............. <br />: Independent lighting controls installed <br />............................ <br />;MComplies <br />........... .............. ......I... ...... <br />Requirement will be met. <br />(EL2ja <br />:per approved lighting plans and all <br />❑Does Not <br />_111,ii <br />„manual controls readily accessible and <br />❑Not Observable. <br />, <br />visible to occupants. <br />❑Not Applicable <br />9 4 1 if <br />Daylight areas under skylights and <br />❑Complies <br />Exception: Requirement does not apply. <br />[EL1311 <br />roof monitors that have more than <br />❑Does Not <br />' <br />150 W combined input power for <br />❑Not Observable: <br />}._....... <br />.general lighting are controlled by <br />;photocontrois. <br />®Not Applicable <br />._...._. <br />9.4,1 3 <br />__.......__-_._.__..__._._..._....._....._...___._....__...._........... <br />Separate lighting control devices for <br />......__..............__........._.............._...__..__-_.__.._......__..__.____---...__.....-...__..-_-_-..._.--__..._.._..__................_...............: <br />:MComplies 'Requirement <br />will be met. <br />[EL4]1 <br />.specific uses installed per approved <br />❑Does Not <br />lighting plans. <br />❑Not Observable <br />' <br />❑Nat Applicable <br />j_ <br />j9.6.2 <br />_ _____ _ _____ <br />!Additional interior lighting power <br />_. <br />MComplies <br />___-_-_-_-__I:: <br />__.,_.._ _ _ .._ ... _,_ ._ <br />Requirement will be met. <br />':, [EL8]' <br />allowed for special functions per the <br />❑Does Not <br />'approved lighting plans and is <br />:automatically controlled and <br />❑Not Observable <br />3 <br />separated from general lighting, <br />❑Not Applicable <br />:. <br />_.. <br />ilia 4 1 Electric motors meet requirements <br />.............. .......... <br />:MComplies !Requirement <br />I..... .... I.---- .. <br />will be met. <br />(L9]2 <br />where applicable. <br />❑Does Not <br />❑Not Observable <br />Y in <br />❑Not Applicable <br />! <br />Y--_m - <br />Additional Comments/Assumptions'�� <br />................. -. T ... ......... _-- ----- ­­_­­_­­­­­ <br />i 1 1 High Impact (Tier 1) 2 :j Medium Impact (Tier 2) , 3 ;Low Impact (Tier 3) <br />Project Title: Houndstown <br />Data filename: E:\2022 Jobs\Houndstown\Zephyr Hills FL\Zephyr Compliance.cck <br />Report date: 03/18/22 <br />Page 10 of 13 <br />M <br />U <br />o� <br />N N Z <br />W V <br />Z W <br />>`t� Z <br />mrXnNW <br />(Dv <br />c F- I Z <br />O <br />W a <br />O Y <br />U) <br />Q u7 <br />o <br />. I <br />Fr <br />00 <br />CO in00 <br />O Z <br />CERTIFIED BY: <br />DRAWN BY: <br />STAFF <br />6440 FORT KING <br />ZEPHYRHILLS, FL <br />33542 <br />DARREN & LUANN <br />Owner <br />L-JANSEN GEHRING <br />317.747.0555 <br />--------I <br />ZEPHYR HILLS 'I 1 <br />i <br />�___ <br />ENERGY FORMS <br />M 101 <br />