Laserfiche WebLink
A <br />0-1 <br />MOP <br />SINK <br />F <br />NOTE: <br />1. ALL FIXTURES DISCHARGING DOWNSTREAM FROM A WATER <br />CLOSET SHALL BE INDIVIDUALLY VENTED PER 901.2 <br />2. REDUCED PRESSURE ASSEMBLY BACKFLOW PREVENTERS ARE <br />REQURIED TO BE INSTALLED WITH ALL SALONS. <br />TYPICAL PLUMBING SANITARY ISOMETRIC <br />N.T.S. <br />SINK <br />4" <br />WC <br />2" <br />PLUMBING EQUIPMENT SCHEDULE <br />MAKE & MODEL NUMBER <br />ITEM <br />DESCRIPTION <br />CAPACITY <br />FUEL TYPE <br />BTUIHR <br />NOTES <br />(OR APPROVED EQUAL) <br />WATER HEATER <br />A.O. SMITH <br />TANK WATER HEATER ON STAND. STAND BY <br />40 GALLONS <br />ELECTRIC <br />4,500 WATTS <br />OR APPROVED EQUAL <br />EH-1)-(IFREQUIRED) <br />ENS-40 <br />CONTRACTOR <br />HOT WATER <br />BELL & GOSSETT <br />RE-CIRC PUMP <br />PL-30 <br />HOT WATER RE -CIRCULATION PUMP <br />1/12 HP <br />OR APPROVED EQUAL <br />SPEED QUEEN <br />11.7 GALLONS PER CYCLE, <br />WASHER/DRYER <br />STEBCASP173TWOI <br />COMBINATION WASHERIDRYER MACHINE <br />3.8 GAL./CU.FT, <br />OR APPROVED EQUAL <br />KRAUS <br />MAXIMUM 2.2 GPM @ 60 PSI <br />SINK <br />PREP SINK W/DELTA #297247 FAUCET <br />1.0 GPM <br />KTM33 <br />OR APPROVED EQUAL <br />MUSTEE <br />MOP BASIN <br />19CF <br />MOP SINK COMPLETE WITH FAUCET AND STOPPER <br />OR APPROVED EQUAL <br />EZ FLO <br />WITH 2.0 LAMINAR FLOW <br />MOP FAUCET <br />10361 <br />CONTROL <br />OR APPROVED EQUAL <br />FLOOR DRAIN <br />SURE SEAL <br />4" INLINE FLOOR DRAIN TRAP SEAL WITH <br />TRAP SEALER <br />SS4009V <br />PROPRIETARY EPDM RUBBER DIAPHRAGM <br />OR APPROVED EQUAL <br />OATEY <br />WASHER BOX <br />OR APPROVED EQUAL <br />F1960 <br />ZURN WILKINS <br />TEMPERED WATER LIMITING DEVICE. CONFORMS <br />TEMPERED WATER REQUIRED <br />TEMPERED WATER MV <br />ZW3870XLT <br />TO ASSE 1070. <br />100° MAXIMUM <br />OATEY <br />ICE MAKER BOX <br />OR APPROVED EQUAL <br />39149 <br />ZURN <br />BACKFLOW <br />OR APPROVED EQUAL <br />975XL2 <br />FI 0L <br />LINT TRAP <br />OR APPROVED EQUAL <br />160 <br />MASTER EQUIPMENT <br />POLYPRO LIFT GROOMING TUB <br />GROOMING TUB <br />OR APPROVED EQUAL <br />TP5856 <br />KOHLER <br />ELONGATED FLOOR MOUNT TOILET <br />WATER CLOSET <br />OR APPROVED EQUAL <br />K-3658-0 <br />KOHLER <br />GREENWICH SINK, WALL MOUNTED <br />LAVATORY <br />OR APPROVED EQUAL <br />K-2032-0 <br />NOTES: <br />1. WASHER/DRYER SHALL BE IN COMPLIANCE WITH SECTION 504.3 OF THE 2009 IMC. <br />2. CONTRACTOR SHALL VERIFY WITH LOCAL CODES AND/OR INSPECTOR IF THE SURE SEAL TRAP SEALER IS ACCEPTABLE. <br />PLAN NOTES: <br />OCONNECT TO EXISTING SANITARY MAIN AS REQUIRED. <br />OSANITARY PIPING SHALL BE RAN UNDER SLAB. <br />OSANITARY PIPING SHALL BE RAN IN WALL. <br />O4 EXISTING TO REMAIN, CAP ALL UNUSED EXISTING CONNECTIONS. VERIFY LOCATION IN FIELD. <br />O3" FLOOR DRAIN, TRAP PRIMER TO NEAREST SINK AND VENT AS REQUIRED. <br />PLUMBING NOTES <br />1. ALL PLUMBING WORK TO BE DONE BY A LICENSED <br />PLUMBING CONTRACTOR AND TO MEET ALL <br />FEDERAL, STATE & LOCAL CODES. <br />2. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY <br />PERMITS AND SHALL PAY ALL REQUIRED FEES FOR <br />THIS WORK. <br />3. THE CONTRACTOR SHALL FIELD VERIFY EXISTING <br />CONDITIONS AND REPORT TO BANYAN <br />CONSTRUCTION, IN WRITING, ANY DISCREPANCIES <br />IMMEDIATELY UPONDISCOVERY. <br />4. KEEP VENT HEIGHT WITHIN SPECIFIED DIMENSIONS. <br />5. KEEP ALL ROUGH PLUMBING WITHIN SPECIFIED <br />DIMENSIONS. <br />6. EXTEND ALL ROUGH PLUMBING FROM WALL. -AS <br />NOTED- <br />7. PLUMBING CONTRACTOR TO VERIFY ALL FIELD <br />MEASUREMENTS. <br />8. PLUMBING CONTRACTOR TO VERIFY PLUMBING <br />REQUIREMENTS FOR ALL FIXTURES & EQUIPMENT <br />PROVIDED BY OWNER. <br />9. WALL THICKNESS MAY VARY FROM PLAN AS <br />SHOWN DEPENDING ON LOCAL REQUIREMENTS <br />AND EXISTING CONDITIONS. <br />10. ALL SINKS FOR EMPLOYEES OR PUBLIC USE SHALL <br />BE A MAXIMUM OF 6-,V' DEEP AND MOUNTED WITH <br />THE TOP EDGE A MAXIMUM 34" A.F.F. SINK DEPTH <br />DOES NOT APPLY TO LAVATORIES. <br />11. ALL FLUSH VALVE HANDLES FOR THE WATER <br />CLOSETS SHALL FACE THE OPEN SIDE OF THE <br />ROOM. G.C. TO PROVIDE POWER FLUSH TOILETS. <br />12. G.C. TO HAVE WATER TESTED TO DETERMINE IF <br />WATER SOFTENER IS NEEDED. <br />13. G.C. TO PROVIDE GAS WATER HEATERS IF <br />AVAILABLE. VERIFY SELECTION W/ OWNER. <br />14. BLOCKING FOR RESTROOM AND BREAKROOM SINKS <br />SHALL BE BY PLUMBER. <br />15. WHEN APPLICABLE, ALL WATER LINES ON EXTERIOR <br />WALLS TO BE INSULATED TO PREVENT FREEZING <br />PLUMBING NOTES <br />WATER PIPING SHALL BE SCHEDULE 40 CPVC UNLESS OTHERWISE NOTED. <br />ALL HOT WATER PIPING TO BE INSULATED (IF APPLICABLE). <br />PROVIDE SHUTOFF VALVES IN SUPPLY LINES TO ALL FIXTURES. <br />ALL PLUMBING FIXTURES AND RELATED SYSTEMS TO BE FURNISHED, INSTALLED AND PLACED <br />IN OPERATION BY THE PLUMBING CONTRACTOR. WATER HEATERS FURNISHED BY G.C. <br />VERIFY ALL A/C CONDENSATION LINES REQUIRED AND INSTALLED TO EXTERIOR OF <br />BUILDING IN A SLIGHTLY MANNER. <br />WASTE WATER LINES TO BE SCHEDULE 40 PVC. <br />VERIFY LOCATION OF ALL SEWER AND WATER CONNECTIONS PRIOR TO START OF WORK. <br />PLUMBING CONTRACTOR TO VERIFY LOCATION OF ALL EXISTING SERVICE LOCATIONS AND <br />SIZE DIMENSIONS ARE TO BE VERIFIED IN THE FIELD TO DETERMINE APPLICABILITY TO <br />EXISTING AND PROPOSED SERVICE. <br />ALL BRANCH PIPING SHALL BE PEX PIPING. <br />ALL GAS PIPING SHALL BE SCHEDULE 40 BLACK STEEL PIPE. <br />ACCESSABLE MAIN SHUT OFF VALVE TO BE LOCATED IN MECHANICAL ROOM 36"-48" A.F.F. <br />2 <br />O <br />_ <br />NU <br />O co 00 <br />�LoZ <br />W <br />W W <br />Z� <br />OpTrNW <br />�.. <br />c� IZ <br />Wo <br />as co cio_ <br />p <br />�o <br />o 2 <br />— a, coI <br />o= p <br />r mcv)�i00 <br />OZ <br />CERTIFIED BY: <br />D RAW N BY: <br />STAFF <br />6440 FORT KING <br />ZEPHYRHILLS, FL <br />33542 <br />DARREN & LUANN <br />Owner <br />CONSTRUCTION <br />JANSEN GEHRING <br />317.747.0555 <br />ZEPHYR HILLS <br />PLUMBING <br />PLAN -WASTE <br />101 <br />