My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6440 Fort King
Zephyrhills
>
Building Department
>
Building Plans
>
6440 Fort King
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 1:40:39 PM
Creation date
2/18/2025 3:27:50 PM
Metadata
Fields
Template:
Building Plans
Street #
6440
Location
Fort King
Contractor
Banyan Construction
Building Plans - Permit #
3809
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
z <br />0 <br />(a) <br />60" DIAMETER SPACE <br />z <br />M <br />3'-0" Ll1'-0" <br />i I <br />I I <br />I I <br />I 1 I <br />I J I <br />I I <br />I I <br />I I <br />I I <br />MFP- <br />(b) <br />T-SHAPE SPACE FOR 180 DEGREE TURN <br />z <br />� I I <br />00 <br />I <br />--L <br />--� <br />18" MIN <br />PICTOGRAM TO COMPLY <br />WITH 703.6 <br />WOMEN <br />SYMBOL OF ACCESSIBILITY <br />TO COMPLY WITH 703.7 <br />TEXT NOT IN PICTOGRAM <br />FIELD (518" TO 2" TALL) <br />GRADE 2 BRAILLE <br />NOTES: <br />1. WHERE A TACTILE SIGN IS REQUIRED, <br />SIGN IS TO BE ON LATCH SIDE OF <br />DOOR, COMPLY WITH 703.4.2 <br />2. ACCESSIBLE SIGNAGE TO COMPLY <br />WITH ADA 703 <br />3. SIGN TO COMPLY WITH 703.4.1 <br />PULL SIDE <br />r <br />w <br />U) I <br />0 <br />U <br />z <br />O 1 1 <br />x I I <br />0 <br />o z <br />� � I <br />OLL o <br />T 2'-0"MIN <br />I <br />32" MIN CLR <br />PUSH SIDE <br />r <br />I I <br />I I <br />z <br />� I I <br />I I <br />T 1 2'-0"MIN <br />ih I <br />I <br />I I <br />32" MIN CLR <br />LATCH SIDE APPROACHES <br />LAVATORY <br />.I <br />0'-8" <br />O <br />M ci <br />I <br />J i, (V N <br />0'-11' CV <br />1' - 5" MIN <br />2'- 6" MIN <br />PULL SIDE <br />PUSH SIDE <br />I I I <br />I I I <br />I I I <br />o I i i <br />1' - 0" MIN IF DOOR ON CLOSER <br />I <br />I <br />I I <br />32" MIN CLR <br />FRONT APPROACHES <br />HAND BLOW DRYER <br />4" PROJECTION MAX <br />MIRROR <br />LAVATORY <br />�L <br />X <br />Q <br />C) <br />' <br />iy) <br />N <br />M <br />GRAB BARS <br />3'-0" 0'-6" <br />M <br />cy) 0 <br />CM <br />ti <br />TOILET <br />PULL SIDE <br />r----------- <br />-----------------1-� <br />I I I <br />I <br />I I I <br />z <br />X=3'-6"MIN <br />I <br />icyow <br />} v 1F Y = 4'-6" MINI <br />X=3'-0"MIN I I <br />I <br />IFY=5'-0"MIN <br />f I <br />32" MIN CLR <br />I I <br />I I <br />z I I <br />g I I <br />I I <br />-------------- <br />2'- 0" MIN <br />i I <br />32" MIN CLR <br />HINGE SIDE APPROACHES <br />' - 0" MAX <br />T- <br />7 <br />7"- 9" <br />1 N <br />I <br />I I <br />a) <br />— <br />- <br />r- <br />fM <br />TOILET <br />TOILET PAPER <br />DISPENSER <br />GRAB BARS <br />cf) <br />co <br />c,`� ,) <br />Cy) <br />1. ALL GUEST ROOMS, MEETING ROOMS, AND OTHER COMMON AREA <br />1. <br />DO NOT SCALE DRAWINGS. <br />ROOMS SHOULD PROVIDE SIGNAGE IN COMPLIANCE WITH <br />2. <br />ALL DOORS IN THE MEAN OF <br />GUIDELINES 3, 4, 5, 6, AND 7 BELOW. <br />2. DIRECTIONAL SIGNAGE - MUST BE LOCATED AT AN INACCESSIBLE <br />EGRESS SHALL BE SINGLE <br />ELEMENT WHICH DIRECTS INDIVIDUALS WITH DISABILITIES TO THE <br />ACTION RELEASE AND <br />NEAREST ACCESSIBLE ELEMENT. <br />SHALL NOT REQUIRE TH E <br />3. CHARACTER PROPORTION - LETTERS AND NUMBERS ON SIGNS <br />USE OF A KEY, TOOL, OR <br />SHALL HAVE A WIDTH TO HEIGHT RATIO BETWEEN 1:5 AND 1:10. <br />4. CHARACTER HEIGHT - CHARACTERS AND NUMBERS ON SIGNS <br />SPECIAL KNOWLEDGE TO <br />SHALL BE SIZED ACCORDING TO THE VIEWING DISTANCE FROM <br />OPEN FROM EGRESS SIDE. <br />WHICH THEY ARE TO BE READ. THE MINIMUM CHARACTER HEIGHT <br />3 <br />EXIT AND EMERGENCY <br />SHOULD BE THREE INCHES. <br />5. RAISED AND BRAILLE CHARACTERS AND PICTORIAL SYMBOLS <br />LIGHTS SHALL BE FULLY <br />SIGNS (PICTOGRAMS) - LETTERS AND NUMERALS SHALL BE RAISED <br />OPERABLE AT THE TIME OF <br />1/32". UPPERCASE, SANS SERIF OR SIMPLE SERIF TYPE SHALL BE <br />THE FIRE FINAL <br />ACCOMPANIED WITH GRADE 2 BRAILLE. RAISED CHARACTERS <br />INSPECTION. <br />SHALL BE AT LEAST 5/8" HIGH, BUT NO HIGHER THAN TWO INCHES. <br />PICTOGRAMS SHALL BE ACCOMPANIED BY THE EQUIVALENT <br />4. <br />ALL INTERIOR FINISHES TO <br />VERBAL DESCRIPTION PLACED DIRECTLY BELOW THE <br />COPMLY WITH LSC 101, <br />PICTOGRAMS. THE BORDER DIMENSION OF THE PICTOGRAM SHALL <br />CHAPTER 10 SEC. 10.2. <br />BE SIX INCHES MINIMUM IN HEIGHT. <br />6. FINISH AND CONTRAST - THE CHARACTERS AND BACKGROUND OF <br />5. <br />ALL EMERGENCY LIGHTS <br />SIGNS SHALL BE EGGSHELL MATTE OR OTHER NO GLARE FINISH <br />AND EXIT SIGNS SHALL <br />CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIR <br />HAVE BATTERY BACKUP. <br />BACKGROUND - EITHER LIGHT CHARACTERS ON A DARK <br />BACKGROUND OR DARK CHARACTERS ON A LIGHT BACKGROUND. <br />6. <br />ALL PORTIONS OF THE <br />7. MOUNTING LOCATION AND HEIGHT - WHERE PERMANENT <br />BUILDING SHALL BE WITHIN <br />IDENTIFICATION IS PROVIDED FOR ROOMS AND SPACES, SIGNS <br />75 FT OF TRAVEL DISTANCE <br />SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE <br />TO AN EXTINGUISHING UNIT <br />OF THE DOOR. WHERE THERE IS NO WALL SPACE TO THE LATCH <br />SIDE OF THE DOOR, INCLUDING DOUBLE LEAF DOORS, SIGNS <br />OR AS REQUIRED BY LOCAL <br />SHALL BE PLACED ON THE NEAREST ADJACENT WALL. MOUNTING <br />FIRE MARSHALL. <br />HEIGHT SHALL BE 60" ABOVE THE FNISHED FLOOR TO THE <br />7 <br />EMERGENCY LIGHTING TO <br />CENTERLINE OF THE SIGN. MOUNTING LOCATION FOR SUCH <br />SIGNAGE SHALL BE SO THAT PERSON MAY APPROACH WITHIN <br />BE VERIFIED FOR PROPER <br />THREE INCHES OF SIGNAGE WITHOUT ENCOUNTERING <br />WORKING CONDITION, <br />PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF THE <br />BATTERY BACKUP IS <br />DOOR. <br />REQUIRED TO MAINTAIN <br />m.. . <br />I <br />LIGHTING FOR A MIN. OF 90 <br />MINUTES AT A MINIMUM <br />THE PROJECT CONSISTS OF AN INTERIOR TENANT REMODEL TO <br />ILLUMINATION OF 1 <br />CONSTRUCT A DOG DAYCARE FACILITY. BACK OF HOUSE IS EMPLOYEE <br />FOOTCANDLE AS PER IBC - <br />ONLY AND WILL HAVE NO PUBLIC ACCESS. THE RECEPTION 1S <br />SECTION 1008. <br />RESTRICTED PUBLIC ACCESS FOR PEOPLE TO DROP OFF AND PICK <br />UPTHEIR DOGS IN THE MORNING AND EVENINGS. THERE WILL BE A MAX <br />NUMBER OF FIVE EMPLOYEES DURING OPERATION. THE RECEPTION <br />AREA CONSTITUTES LESS THAN 25% OF THE TOTAL AREA OF THE SPACE. <br />PROPOSED USE: DOG DAYCARE <br />OWNER'S AUTHORAIZED AGENT: JANSEN GEHRING TEL: 317.747.0555 <br />OWNED BY A PRIVATE OWNER <br />LEAD DESIGN PROFESSIONAL: CORTLAND MORGAN <br />CODE: 2020 FBC <br />GROSS PROJECT AREA - 4305.45 SF <br />OCCUPANT LOAD - MAX 10 <br />USE GROUP - B <br />HEIGHT OF BUILDING - 15'-0" <br />CONSTRUCTION TYPE - TYPE II B, NON SPRINKLERED <br />FIRE PROTECTION REQUIREMENTS <br />ROOF SYSTEM - EXISTING TO REMAIN <br />BEARING WALLS - NON-COMBUSTIBLE <br />STRUCTURAL FRAME - NON-COMBUSTIBLE <br />NON -BEARING WALLS - NON-COMBUSTIBLE MATERIAL <br />LIFE SAFETY REQUIREMENTS <br />EMERGENCY LIGHTING - YES <br />EXIT SIGNS - YES <br />FIRE ALARM - YES - DEFERRED SUBMITTAL <br />STRUCTURALLOADS <br />APPROVED BY ORIGINAL BUILDING PERMIT - TENANT BUILD -OUT DOES <br />NOT ALTER BUILDING STRUCTURAL SYSTEM. <br />2020 FLORIDA BUILDING CODE, 7TH EDITION (FBC) <br />2020 FBC - PLUMBING, 7TH EDITION <br />2020 FBC - MECHANICAL, 7TH EDITION <br />2020 FBC - RESIDENTIAL CODE, 7TH EDITION <br />2020 FBC - FUEL GAS, 7TH EDITION <br />2020 FFPC, 7TH EDITION <br />2020 FBC - ENERGY CONSERVATION, 7TH EDITION <br />NATIONAL ELECTRICAL CODE 2017 OF FLORIDA (NEC) <br />ACCESSIBILITY CODE: [CC/ANSI 117.1-2009 <br />CONSTRUCTION TYPE CLASSIFICATION: TYPE H B <br />FIRE SPRINKLER SYSTEM: NO <br />TRAVEL DISTANCE (B): <br />200' MAX ALLOWED <br />COMMON PATH: <br />75' MAX ALLOWED <br />DEAD END CORRIDOR: <br />20' MAX ALLOWED <br />TOTAL DIAGONAL LENGTH: <br />= 104' - 1" <br />MIN. ALLOWED EXIT REMOTENESS: <br />= 52' - 1/2" <br />PROVIDED EXIT REMOTENESS: <br />= 78' - 0 7/8" <br />EGRESS WIDTH REQUIRED: <br />32" (x2) <br />EGRESS WIDTH PROVIDED: <br />32" (x4) <br />ACCESSIBLE PARKING <br />APPROVED BY ORIGINAL BUILDING PERMIT -TENANT BUILDOUT DOES NOT <br />ALTER PARKING ON SITE. <br />B OCCUPANCY (10 PEOPLE) <br />WATER CLOSET: <br />1 REQUIRED, 1 PROVIDED <br />LAVATORY: <br />1 REQUIRED; 1 PROVIDED <br />FIRE EXTINGUISHER SPECIFICATION <br />LARSEN - CAMEO SERIES MODEL #SS C2409-R (OR APPROVED EQUAL W/ <br />ANNUAL SERVICE TAGS. <br />MOUNTING HEIGHTS - SEE DETAIL THIS SHEET <br />A. ADA GUIDLINES TO SPECIFY REACH RANGES FOR BUILDING <br />OCCUPANTS WHO REQUIRE ACCESS TO EQUIPMENT SUCH AS FIRE <br />EXTINGUISHERS AND OTHER FIRE SAFETY DEVICES. <br />B. FOR AN UNOBSTRUCTED APPROACH, THE MAXIMUM FORWARD <br />REACH TO THIS EQUIPMENT (FOR EXAMPLE, THE FIRE <br />EXTINGUISHER HANDLE) IS 48" ABOVE THE FLOOR. THE MAXIMUM <br />SIDE REACH FOR SUCH AN APPROACH IS 54". THE ACTUAL <br />MOUNTING HEIGHTS FOR CABINETS HOUSING THIS EQUIPMENT <br />CAN BE DETERMINED BY REVIEWING THE EXACT DIMENSIONS OF <br />THE SPECIFIED CABINET AND THE POSITIONING OF THE FIRE <br />EQUIPMENT WITHIN THAT CABINET. PLEASE NOTE THAT THESE <br />ADAAG REACH RANGE REQUIREMENTS FALL WITHIN THE NFPA <br />(NATIONAL FIRE PROTECTION ASSOCIATION) GUIDELINES. THE <br />NFPA GUIDELINES STATE THAT THE DISTANCE FROM THE FLOOR <br />TO THE TOP OF THE FIRE EXTINGUISHER TO BE NO MORE THAN 5'. <br />C. FIRE EXTINGUISHER SIGNS SHALL BE LOCATED BY ALL EXIT DOORS <br />AND EVERY 75' THEREAFTER. FIRE EXTINGUISHERS ARE TO BE <br />LOCATED SUCH THAT TRAVEL DISTANCE DOES NOT EXCEED 75'. <br />D. MOUNTING BRACKET AT HEIGHT REQUIRED TO PERMIT FIRE <br />EXTINGUISHER ACCESS AT 48" MAX. AFF. FIRE EXTINGUISHERS <br />SHALL BE LOCATED PER THE REQUIREMENTS OF NFPA 10, <br />CHAPTER 10, CURRENT EDITION. <br />E. THE SIZE SHALL BE A MINIMUM OF 2 A_10_B/C. <br />F. EXACT NUMBER AND LOCATIONS FOR REQUIRED FIRE <br />EXTINGUISHERS TO BE DETERMINED BY THE GC AT THE <br />DISCRETION OF THE FIRE INSPECTOR FOR THE JURISDICTION <br />ISSUING THE PERMIT FOR THIS PROJECT. <br />G. F.E. - FIRE EXTINGUISHERS SHALL BE 5LB ABC TYPE AT LOCATIONS <br />INDICATED. <br />C 0 R I L A NI D <br />m 0 R G A NI <br />ARCH LC <br />711 N. FIELDER RD. <br />ARLI NGTON, TX 76012 <br />PH: (817) 635.5696 <br />FAX: (817) 635.5699 <br />CERTIFIED BY: <br />;U <br />A R-0015586 ; <br />rj <br />r <br />ED A <br />CORTLAND MORGAN <br />FLORIDA REG. AR - 0015586 <br />D RAW N BY: <br />STAFF <br />90% <br />� rM <br />6440 FORT KING <br />ZEPHYRHILLS, FL <br />33542 <br />DARREN & LUANN <br />Owner <br />min <br />CONSTRUCTION <br />JANSEN GEHRING <br />317.747.0555 <br />W391mm-9:a:IIIIK <br />LIFE SAFETY <br />LIFE SAFETY PLAN <br />3/16 1'-0" <br />— - EXIT ACCESS PATH <br />• START OF EXIT PATH <br />_ DIAGONAL DISTANCE <br />OF SPACE <br />G101 <br />3/17/2022 4:14:19 PM <br />
The URL can be used to link to this page
Your browser does not support the video tag.