Laserfiche WebLink
0 <br />U <br />n <br />N <br />0 <br />0 <br />w <br />E <br />/1 r- K I r r"1 A I <br />1. ALL WORK PERFORMED AND ALL MATERIALS FURNISHED SHALL CONFORM TO THE <br />2004 FLORIDA BUILDING CODE WITH 2O06 REVISIONS, ALL APPLICABLE FEDERAL <br />AND LOCAL CODES, AND UTILITY COMPANY REQUIREMENTS. <br />2. THE DRAWINGS ARE DIAGRAMMATIC AND THE OMISSION OF AN ITEM FOR THE <br />PROPER FUNCTIONING OF THE SYSTEM DOES NOT RELIEVE THE EC FROM PROVIDING <br />THAT ITEM. <br />3. ALL MATERIALS AND EQUIPMENT SHALL BE NEW, UL-LISTED AND LABELED. EC <br />SHALL PROVIDE ALL LABOR NECESSARY FOR A COMPLETE AND PROPERLY <br />OPERATING SYSTEM. ALL ELECTRICAL WORK SHALL BE DONE IN A NEAT AND <br />WORKMANLIKE MANNER. <br />4. COORDINATE ALL ELECTRICAL WORK WITH THAT OF OTHER TRADES AND AVOID <br />INTERFERENCE WITH STRUCTURES AND WITH WORK OF OTHER TRADES. <br />5. BEFORE SUBMITTING BID, CONTRACTOR SHALL VISIT AND BE RESPONSIBLE FOR <br />HAVING ASCERTAINED LOCAL CONDITIONS SUCH AS LOCATION, ACCESSIBILITY AND <br />GENERAL CHARACTER OF THE SITE, EXTENT OF REMOVAL AND INSTALLATION WORK. <br />THE CONTRACTOR SHALL FULLY EXAMINE ALL DRAWINGS RELATING TO THE WORK <br />AND BECOME COMPLETELY INFORMED OF THE EXTENT AND CHARACTER OF THE <br />WORK REQUIRED AND OF THE PREVAILING EXISTING CONDITIONS. NO ALLOWANCES <br />SHALL BE MADE FOR THE CONTRACTOR'S FAILURE TO AVAIL HIMSELF OF THIS <br />INFORMATION. <br />6. BEFORE ORDERING ANY MATERIALS OR EQUIPMENT, THE EC SHALL SUBMIT <br />ENGINEERING DATA FOR ALL MATERIALS AND EQUIPMENT HE PROPOSES TO FURNISH <br />AND INSTALL. THE EC SHALL BE RESPONSIBLE FOR CHECKING EQUIPMENT <br />DIMENSIONS OF THE PROPOSED SUBSTITUTE EQUIPMENT AND SHALL BE <br />RESPONSIBLE FOR IT FITTING IN THE SPACE AVAILABLE. THE COST OF ANY <br />REDESIGN CAUSED BY A SUBSTITUTION SHALL BE BORNE BY THE EC. <br />7. THE EC SHALL DO ALL CUTTING, DRILLING AND PATCHING REQUIRED BY HIS WORK. <br />STRUCTURAL MEMBERS SHALL NOT BE CUT, UNLESS APPROVED BY THE ENGINEER. <br />8. THE EC SHALL CONFIRM THE LOCATION OF ALL EXISTING UTILITIES AND BE <br />RESPONSIBLE FOR REPAIRING ANY DAMAGES HE CAUSES. <br />9. EC SHALL PROVIDE A ONE-YEAR WARRANTY FROM THE DATE OF SUBSTANTIAL <br />COMPLETION THAT COVERS ALL DEFECTS IN WORKMANSHIP OR MATERIALS. <br />10. EC SHALL MAINTAIN TWO SETS OF PROGRESS DRAWINGS INDICATING ALL CHANGES <br />IN EQUIPMENT OR LOCATION FROM THE DESIGN DOCUMENTS. EC SHALL PROVIDE <br />ONE SET OF PROGRESS DRAWINGS FOR ENGINEER'S REVIEW AT SUBSTANTIAL <br />COMPLETION. <br />11. PROVIDE TWO OPERATION AND MAINTENANCE MANUALS TO OWNER PRIOR TO <br />PROJECT CLOSE OUT. MANUALS SHALL INCLUDE SUBMITTAL DATA STATING <br />EQUIPMENT RATINGS AND SELECTED OPTIONS FOR ALL EQUIPMENT REQUIRING <br />MAINTENANCE. ROUTINE MAINTENANCE PROCEDURES SHALL BE CLEARLY IDENTIFIED. <br />MANUALS SHALL INCLUDE NAME AND ADDRESS OF AT LEAST ONE QUALIFIED <br />SERVICE AGENCY. <br />GROUNDING <br />1. PROVIDE A COMPLETE GROUNDING SYSTEM FOR THE ENTIRE ELECTRICAL SYSTEM AS <br />REQUIRED BY ARTICLE 250 OF THE NEC. <br />2. ALL GROUNDING WIRE, LUGS, JUMPERS AND BUS SHALL BE COPPER. GROUND <br />RODS SHALL BE 5/8" DIAMETER BY 10-FOOT COPPER -CLAD, STEEL RODS. <br />3. ALL FEEDER AND BRANCH CIRCUITS SHALL CONTAIN AN EQUIPMENT -GROUND WIRE. <br />NO METAL CONDUIT OF ANY KIND OR LENGTH SHALL BE USED AS THE <br />EQUIPMENT -GROUNDING CONDUCTOR. <br />4. EQUIPMENT -GROUNDING CONDUCTORS AND STRAPS SHALL BE SIZED IN <br />ACCORDANCE WITH THE NEC, UNLESS OTHERWISE NOTED. ALL <br />EQUIPMENT -GROUNDING CONDUCTORS SHALL BE PROVIDED WITH GREEN INSULATION <br />EQUIVALENT TO THE INSULATION ON THE ASSOCIATED PHASE CONDUCTORS. <br />5. METAL AND CONCRETE POLES SUPPORTING OUTDOOR LIGHTING FIXTURES SHALL BE <br />GROUNDED WITH A SUPPLEMENTAL GROUND ROD IN ADDITION TO THE BRANCH <br />CIRCUIT EQUIPMENT -GROUNDING CONDUCTOR. <br />6. GROUNDING CONDUCTORS SHALL BE CONTINUOUS. NO SPLICING OF CONDUCTORS <br />UNLESS ALLOWED BY THE NEC. <br />7. MAKE GROUNDING CONNECTIONS IN SUCH A MANNER AS TO MINIMIZE THE <br />POSSIBILITY OF GALVANIC ACTION OR ELECTROLYSIS. SELECT CONNECTORS, <br />CONNECTION HARDWARE, CONDUCTORS AND CONNECTION METHODS SO DIRECTLY <br />CONTACTED METALS WILL BE GALVANICALLY COMPATIBLE. <br />8. MEASURE GROUNDING -ELECTRODE SYSTEM RESISTANCE AND PROVIDE THE TEST <br />REPORT TO THE ENGINEER VERIFYING COMPLIANCE WITH REQUIREMENTS. <br />IDENTIFICATIONS <br />1. COMPLY WITH GOVERNING REGULATIONS AND REQUESTS OF GOVERNING AUTHORITIES <br />FOR IDENTIFICATION OF ELECTRICAL WORK. <br />2. DYMO (OR EQUIVALENT) LABELS SHALL NOT BE USED. <br />3. APPLY SELF -ADHERING VINYL OR HEAT -SHRINK PLASTIC CABLE/CONDUCTOR <br />IDENTIFICATION MARKERS ON EACH CABLE AND CONDUCTOR IN EACH BOX, <br />ENCLOSURE, OR CABINET WHERE WIRES OF MORE THAN ONE CIRCUIT ARE PRESENT, <br />EXCEPT WHERE ANOTHER FORM OF IDENTIFICATION, SUCH AS COLOR -CODED <br />CONDUCTORS, IS PROVIDED. MATCH IDENTIFICATION WITH MARKING SYSTEM USED IN <br />PANELBOARDS, SHOP DRAWINGS AND CONTRACT DOCUMENTS. <br />4. DELAY INSTALLATION OF IDENTIFICATION UNTIL PAINTING IS COMPLETE. <br />BOXES <br />1. INTERIOR OUTLET BOXES SHALL BE GALVANIZED STEEL, MINIMUM 14-GAUGE, NO <br />LESS THAN 4' SQUARE 1-1/2" DEEP, WITH EXTENSION RINGS AND MOUNTING <br />BRACKETS. <br />2. JUNCTION AND PULL BOXES SHALL HAVE SCREW -ON COVERS OR LOCKING HINGED <br />COVERS. NEMA 1 BOXES SHALL BE USED INDOORS. NEMA 3R BOXES WITH <br />THREADED HUBS SHALL BE USED OUTDOORS. <br />3. OUTLET BOXES SHALL BE RIGIDLY AND SECURELY FASTENED IN PLACE. <br />4. BOXES SHALL BE SIZED IN ACCORDANCE WITH NEC ARTICLE 314. <br />5. ALL CONDUIT CONNECTORS AND ENTRY HUBS SHALL BE INSULATED OR HAVE <br />INSULATED BUSHINGS. <br />ELECTRICAL SPECIFICATIONS <br />TrrTi r, i � <br />1. THOROUGHLY CLEAN THE ELECTRICAL EQUIPMENT AND ASSOCIATED ELECTRICAL <br />MATERIALS BEFORE ENERGIZATION OF ANY PART OF THE ELECTRICAL SYSTEM. IT IS <br />THE EC'S RESPONSIBILITY TO HAVE ALL THE ELECTRICAL EQUIPMENT, RACEWAYS, <br />CABLING, CABLE INSULATION AND OTHER RELATED ELECTRICAL SYSTEMS TESTED. <br />ALL TEST RESULTS SHALL BE RECORDED, DATED AND SUBMITTED TO THE ENGINEER <br />AND OWNER FOR RECORD. TEST PROCEDURES AND RESULTS SHALL BE PER NETA <br />STANDARDS. IN THE ABSENCE OF RELEVANT NETA STANDARDS, THE EC SHALL <br />SUBSTITUTE APPROPRIATE TEST PROCEDURES FROM IEEE OR ANSI. THE SUBSTITUTE <br />TEST PROCEDURES SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL BEFORE <br />CONDUCTING THE TESTS. <br />2. THE EC SHALL VERIFY THAT EACH KEY SYSTEM INTERFACES CORRECTLY WITH ALL <br />RELATED SYSTEMS. THE EC SHALL FURNISH ALL TEST DATA TO THE ENGINEER <br />VERIFYING THAT ALL SYSTEMS HAVE BEEN INSTALLED CORRECTLY AND ARE WORKING <br />TOGETHER TO PROVIDE A COMPLETE, OPERATIONAL ELECTRICAL SYSTEM AS <br />DESIGNED. <br />WIRE AND CABLE <br />1. ALL WIRE SHALL BE COPPER WITH INSULATION RATED AT 600-VOLTS, 75-DEGREES <br />CELSIUS MINIMUM. WIRE SHALL BE SOLID TYPE THHN OR THWN UP TO SIZE 10 <br />AWG AND STRANDED TYPE THWN, XHHW, OR THHN FOR SIZE 8 AWG AND LARGER <br />(UNLESS OTHERWISE NOTED). <br />2. MINIMUM WIRE SIZES SHALL BE #12 FOR POWER WIRING AND #14 FOR CONTROL <br />WIRING. <br />3. MOLDED CONNECTORS (WIRE NUTS) MAY BE USED FOR SPLICING SIZE 10 AWG OR <br />SMALLER WIRES ON LIGHTING AND RECEPTACLE CIRCUITS ONLY. ALL OTHER WIRING <br />SHALL BE SPLICED WITH BARREL SPLICES, LUGS AND/OR TERMINAL BLOCKS OR <br />APPROVED MOLDED CONNECTORS. <br />4. TERMINAL LUGS SHALL BE MECHANICAL CLAMP OR COMPRESSION TYPE, UNLESS <br />PART OF A CIRCUIT BREAKER OR SWITCH ASSEMBLY. SET -SCREW TYPE LUGS, IN <br />WHICH THE SET SCREW BEARS DIRECTLY ON THE CONDUCTOR, SHALL NOT BE <br />USED. <br />5. SPECIAL LUGS MAY BE REQUIRED TO ACCOMMODATE CONDUCTOR SIZES SHOWN ON <br />THE DRAWINGS. EC SHALL VERIFY LUG REQUIREMENTS FOR ALL CIRCUIT BREAKERS <br />AND EQUIPMENT TERMINALS AND SHALL PROVIDE CORRECT LUGS AS REQUIRED. <br />6. FEEDERS AND SERVICE LATERALS SHALL NOT BE SPLICED WITHOUT ENGINEER'S <br />WRITTEN APPROVAL. <br />7. BRANCH CIRCUIT CONDUCTORS SHALL BE INCREASED, AS REQUIRED, TO PROVIDE A <br />MAXIMUM THREE PERCENT VOLTAGE DROP. <br />8. INSTALL WIRE CABLES AND CONNECTORS IN COMPLIANCE WITH NEC ACCORDING TO <br />MANUFACTURER'S WRITTEN INSTRUCTIONS AND NECA'S "STANDARD OF INSTALLATION." <br />9. METAL -CLAD CABLE MAY BE USED IN INDOOR ACCESSIBLE AREAS ONLY. NOT FOR <br />CONCEALED LOCATIONS. METAL -CLAD CABLE SHALL HAVE EQUIPMENT GROUNDING <br />CONDUCTOR SIZED PER NEC 250.122. <br />10. COLOR CODE SERVICE, FEEDER AND BRANCH CIRCUIT CONDUCTORS WITH <br />FACTORY -APPLIED COLOR AS FOLLOWS: <br />CONDUCTOR 120 208V 277 480V <br />PHASE A BLACK BROWN <br />PHASE B RED ORANGE <br />PHASE C BLUE YELLOW <br />NEUTRAL WHITE GREY OR WHITE WITH COLOR STRIPE <br />GROUND GREEN GREEN <br />ISOLATED GND GREEN/YELLOW <br />RACEWAY <br />1. USE THE FOLLOWING WIRING METHODS: <br />INDOORS OUTDOORS <br />CONCEALED EMT RMC, IMC OR RNC <br />EXPOSED EMT RMC, IMC OR RNC <br />DAMP LOCATIONS RMC OR RNC <br />UNDERGROUND RNC <br />CONNECTIONS TO LFMC, LFNC LFMC OR LFNC <br />VIBRATING EQUIPMENT OR FMC <br />BOXES/ENCLOSURES NEMA 1 NEMA 3R <br />2. MINIMUM CONDUIT SIZE SHALL BE 3/4'. <br />3. ALL RACEWAY SHALL COMPLY WITH THE NEC AND ALL STATE AND LOCAL <br />REGULATIONS. <br />4. ALL NEW RACEWAYS IN FINISHED AREAS SHALL BE CONCEALED, UNLESS <br />SPECIFICALLY NOTED OTHERWISE. <br />5. GROUT AROUND ALL CONDUITS AT CEILING, FLOOR AND WALL PENETRATIONS TO <br />PROVIDE AN AIRTIGHT SEAL. ALL FLOOR SLAB AND FIRE -RATED WALL PENETRATIONS <br />SHALL BE SEALED WITH FIREPROOF COMPOUND. <br />6. GROUP TOGETHER EXPOSED CONDUIT WHERE POSSIBLE. INSTALL ALL CONDUITS <br />EITHER PARALLEL OR PERPENDICULAR TO THE BUILDING SURFACES. MOUNT ON <br />CHANNEL STRUT SUPPORTS OR BUILDING STRUCTURE <br />7. ALL CONDUITS SHALL BE RIGIDLY SUPPORTED TO THE BUILDING STRUCTURE. THE <br />MAXIMUM SPACING OF SUPPORTS SHALL BE AS FOLLOWS: <br />A. VERTICAL RUNS - 10 FEET <br />B. HORIZONTAL RUNS - 8 FEET <br />CONDUITS SHALL NOT BE SUPPORTED FROM SUSPENDED CEILING -SUPPORT WIRES. <br />B. ALL CONDUIT BENDS SHALL BE MADE WITH AN APPROVED CONDUIT BENDER AND <br />NO BEND SHALL HAVE A CENTERLINE RADIUS LESS THAN SIX TIMES THE DIAMETER <br />OF THE CONDUIT. <br />9. EC SHALL COORDINATE RACEWAY IN SLAB WITH STRUCTURAL ENGINEER. <br />10. USE RACEWAY FITTINGS THAT ARE OF TYPES COMPATIBLE WITH THE ASSOCIATED <br />RACEWAY AND SUITABLE FOR THE USE AND LOCATION. EMT FITTINGS SHALL BE <br />STEEL OR CAST SET -SCREW TYPE INDOOR AND STEEL COMPRESSION TYPE <br />OUTDOOR. <br />11. INSTALL EXPANSION COUPLINGS IN THE SLAB WHEN CROSSING BUILDING EXPANSION <br />JOINTS OR OTHER LOCATIONS REQUIRED BY NEC. <br />DEVICES <br />1. EC SHALL VERIFY COLOR, LOCATION AND MOUNTING HEIGHT OF ALL DEVICES AND <br />WALLPLATES WITH ARCHITECT PRIOR TO INSTALLATION. <br />2. DEVICES SHALL BE LEVITON OR EQUIVALENT, AS INDICATED BELOW: <br />DUPLEX RECEPTACLE 5362 <br />SINGLE RECEPTACLE 5361 <br />GFCI RECEPTACLE 6899 <br />IG RECEPTACLE 8300-IQ <br />SINGLE -POLE SWITCH 1221-2 <br />DOUBLE -POLE SWITCH 1222-2 <br />THREE-WAY SWITCH 1223-2 <br />3. RECEPTACLE AND SWITCH WALLPLATES ARE TO BE NYLON WALLPLATES, GANGED TO <br />MATCH THE INSTALLED DEVICES. DEVICE WALLPLATES IN KITCHEN, BAR AND <br />WAITRESS STATION TO BE STAINLESS STEEL. <br />EQUIPMENT <br />1. EC IS RESPONSIBLE FOR THE COMPLETE INSTALLATION OF ALL EQUIPMENT SHOWN <br />ON THE DRAWINGS. ALL MANUFACTURERS' SPECIFICATIONS SHALL BE FOLLOWED <br />CONCERNING THE INSTALLATION OF ALL EQUIPMENT. ANY SPECIAL MANUFACTURERS' <br />REQUIREMENTS NECESSARY FOR THE PROPER OR SAFE INSTALLATION OF <br />EQUIPMENT, REGARDLESS OF WHETHER THE AFOREMENTIONED SPECIAL <br />REQUIREMENTS ARE INDICATED ON THE DRAWINGS, SHALL BE AT THE EXPENSE AND <br />RESPONSIBILITY OF THE EC. <br />2. EC IS RESPONSIBLE FOR THE PURCHASE, RIGGING, ERECTION, INSTALLATION AND <br />FUNCTIONAL OPERATION OF ALL ELECTRICAL EQUIPMENT, EXCEPT WHERE NOTED. <br />3. ALL LOCATIONS OF EQUIPMENT AND FIXTURES ARE APPROXIMATE AND MAY REQUIRE <br />MINOR ADJUSTMENT TO SUIT FIELD CONDITIONS. ALL ADJUSTMENTS SHALL BE <br />SUBMITTED TO THE ENGINEER FOR APPROVAL. <br />4. COORDINATE ALL RECEPTACLES, PLUGS, WIRING AND LOCATIONS WITH THE <br />EQUIPMENT PROVIDED PRIOR TO ROUGH -IN. <br />PANELBOARDS <br />1. ALL PANELBOARDS SHALL BE EQUIPPED WITH A HINGED, LOCKING DOOR. TWO KEYS <br />SHALL BE FURNISHED WITH EACH CABINET AND ALL LOCKS ON ALL CABINETS <br />SHALL BE KEYED ALIKE. <br />2. WHERE PANELS OCCUR ADJACENT TO ONE ANOTHER, THE TOPS OF THE PANELS <br />SHALL BE MOUNTED AT THE SAME HEIGHT. <br />3. PANELBOARDS SHALL BE PAINTED WITH GRAY LACQUER, RUST -PREVENTATIVE <br />PRIMER. SIDES AND TOP OF SURFACE -MOUNTED PANELS SHALL BE PAINTED TO <br />MATCH FRONTS. <br />4. BRANCH CIRCUIT BREAKERS SHALL BE BOLT -ON TYPE AND SHALL BE OF THE <br />AMBIENT COMPENSATED, THERMAL MAGNETIC TYPE, WHICH WILL PROVIDE INVERSE <br />TIME DELAY OVERLOAD AND INSTANTANEOUS SHORT CIRCUIT PROTECTION. VOLTAGE <br />AND CURRENT RATINGS SHALL BE AS INDICATED ON THE DRAWINGS. <br />5. PROVIDE A TYPEWRITTEN DIRECTORY FOR EACH PANEL AND PLACE INSIDE THE <br />PANEL DOOR. THE DIRECTORY SHALL LIST ALL ROOMS SERVED BY EACH BREAKER, <br />USING THE OWNER'S ROOM NUMBERS. DIRECTORIES SHALL BE INSTALLED IN A <br />METAL DIRECTORY FRAME WITH CLEAR PROTECTIVE COVER. SPARES AND SPACES <br />SHALL BE NOTED. <br />6. PANELS 68-INCHES OR LESS IN HEIGHT SHALL BE INSTALLED WITH THE TOP OF <br />THE PANEL 6-FEET ABOVE THE FINISHED FLOOR. ALL PANELS SHALL BE INSTALLED <br />IN ACCORDANCE WITH NEC 404 AND 408. <br />7. EACH PANEL SHALL BE EQUIPPED WITH A GROUND BUS. <br />8. CIRCUIT BREAKERS SHALL BE MANUFACTURED BY THE MANUFACTURER OF THE <br />PANELBOARDS. <br />9. MOUNT PANELS IN LOCATIONS SHOWN, MAKING SURE THAT CODE -REQUIRED <br />CLEARANCES EXIST. <br />10. IF PAINT IS DAMAGED DURING SHIPPING OR INSTALLATION, DAMAGED PORTION SHALL <br />BE SANDED UNTIL SMOOTH AND ENTIRE PANEL REPAINTED. <br />11. ALL BUS SHALL BE COPPER. <br />12, PROVIDE ENGRAVED, LAMINATED PLASTIC NAMEPLATE ON EACH PANELBOARD <br />MOUNTED WITH EPDXY. <br />13. FOR FLUSH PANELBOARDS, SUPPLY ONE 3/4" CONDUIT FROM PANEL TO ABOVE <br />ACCESSIBLE CEILING FOR EACH THREE SPARE BREAKERS OR SPACES TO PROVIDE <br />FOR FUTURE BREAKERS. <br />14. PROVIDE FLASH HAZARD WARNING MARKER IN ALL NEW PANELS. <br />15. AFTER BUILDING IS IN OPERATION, EC SHALL MEASURE PANELBOARD LOADS AND <br />REARRANGE CIRCUITS AS NECESSARY TO BALANCE PHASE LOADS WITHIN 20 <br />PERCENT. COORDINATE WITH OWNER. <br />LIGHTING <br />1. ALL EXIT AND EMERGENCY LIGHTING IS TO BE CONNECTED TO THE UNSWITCHED <br />LEG OF THE LOCAL LIGHTING CIRCUIT. <br />2. INSTALL LUMINAIRES AND POLES ACCORDING TO THE MANUFACTURER'S <br />RECOMMENDATIONS. <br />3. CLEAN UNITS AFTER INSTALLATION AND ADJUST LUMINAIRES, AS REQUIRED. <br />4. LIGHTING CONTROL RELAY PANEL SHALL BE CAPABLE OF ACCEPTING TWO #10 <br />CONDUCTORS ON BOTH LINE AND LOAD SIDE. <br />5. LIGHTING CONTROL MANUFACTURER SHALL PROVIDE COMMISSIONING OF THE <br />INSTALLED SYSTEM INCLUDING ENGRAVING OF KEYPAD BUTTONS. <br />6. LIGHTING CONTROL MANUFACTURER SHALL PROVIDE A MINIMUM OF FOUR HOURS OF <br />OWNER TRAINING ON SYSTEM OPERATION. <br />A <br />AFF <br />AFG <br />AHJ <br />AHU <br />AIC <br />ANSI <br />ATS <br />BKR <br />BLDG <br />C <br />CAB <br />CIR <br />CU <br />CWP <br />EC <br />EF <br />EM <br />EMS <br />EWC <br />EWH <br />FAC P <br />FARA <br />FATC <br />FPL <br />FTL <br />GEN <br />GFCI <br />GND <br />HOA <br />HP <br />HPS <br />IEEE <br />I <br />KVA <br />KW <br />MCC <br />MH <br />M LO <br />NEC <br />NEUT <br />NL <br />NO <br />NTS <br />OC <br />PC <br />PE <br />PNL <br />REC <br />STB <br />TC <br />TVSS <br />TYP <br />UPS <br />UON <br />V <br />VFD <br />WP <br />XFMR <br />BLTI1_DIN(3 SHP, Ll (-)IMJ W1T11 <br />ALL 4PPL1C0.BLE 3-JiLDLN6, <br />ELECTRICAL, P1,UN4_Bl C- AND <br />TAECHP,NICAi CODES <br />ABBREVIATIONS <br />AMPERES <br />ABOVE FINISHED FLOOR <br />ABOVE FINISHED GRADE <br />AUTHORITY HAVING JURISDICTION <br />AIR HANDLING UNIT <br />AMPERE INTERRUPTING CURRENT <br />AMERICAN NATIONAL STANDARDS INSTITUTE <br />AUTOMATIC TRANSFER SWITCH <br />BREAKER <br />BUILDING <br />CONDUIT <br />CABINET <br />CIRCUIT <br />COPPER <br />COLD WATER PIPE <br />ELECTRICAL CONTRACTOR <br />EXHAUST FAN <br />EMERGENCY <br />ENERGY MANAGEMENT SYSTEM <br />ELECTRIC WATER COOLER <br />ELECTRIC WATER HEATER <br />FIRE ALARM CONTROL PANEL <br />FIRE ALARM REMOTE ANNUNCIATOR <br />FIRE ALARM TERMINAL CABINET <br />FLORIDA POWER AND LIGHT <br />FEED THROUGH LUGS <br />GENERATOR <br />GROUND FAULT CIRCUIT INTERRUPTER <br />GROUND <br />HAND -OFF -AUTOMATIC <br />HORSEPOWER <br />HIGH PRESSURE SODIUM <br />INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS <br />ISOLATION GROUND <br />KILOVOLT -AMPERES <br />KILOWATT <br />MOTOR CONTROL CENTER <br />METAL HALIDE <br />MAIN LUGS ONLY <br />NATIONAL ELECTRICAL CODE <br />NEUTRAL <br />NIGHT LIGHT <br />NUMBER <br />NOT TO SCALE <br />ON CENTER <br />PHOTOCELL <br />PROGRESS ENERGY <br />PANELBOARD <br />RECEPTACLE <br />SYSTEMS TERMINAL BOARD <br />TIME CLOCK <br />TRANSIENT VOLTAGE SURGE SUPPRESSOR <br />TYPICAL <br />UNINTERRUPTABLE POWER SUPPLY <br />UNLESS OTHERWISE NOTED <br />VOLT <br />VARIABLE FREQUENCY DRIVE <br />WEATHERPROOF <br />TRANSFORMER <br />RFWTEW DA T E:_)�_2-? <br />CITY OF.Zl pHyRi;I 1 _ <br />BUI[LD1,NG OPP4-IAI. <br />DICKENS & ASSOCIATES, INC. <br />232 Bay Street Phone: (386) 253-1511 <br />Daytona Beach, FL 32114 Fax: (386) 252-0673 <br />CA #: 002396 Project #: 4542.00 <br />Engineer: Stephen Byrne PE #: 17584 <br />U <br />z <br />0 <br />(D copyright <br />0 <br />W <br />L. <br />revisions: <br />A <br />0 <br />0 <br />drawn: <br />checked <br />date: <br />prof. no <br />0`_ N4_� <br />Ln Lr) 6 <br />� i O <br />U U lb <br />00 00 N <br />r\ r\ <br />CD CD <br />v <br />c o <br />o <br />s <br />Q <br />a� 00 <br />N <br />c c,.) <br />0 _0 <br />O <br />c .} <br />0 <br />c <br />� � o <br />Ln u) O <br />� 00 <br />T Ln <br />co r*, <br />WE <br />V)cr-- <br />N <br />V- <br />Ln <br />C <br />L ,I"JYy)� <br />O 0 <br />> _0 <br />(1) _ <br />L <br />O O <br />0 - <br />0 s <br />-'o T <br />O s <br />�O Q. <br />,-o N <br />slb <br />spb <br />3-21-08 <br />P07-15B <br />EO.O1 <br />