Laserfiche WebLink
I <br />ELECTRICAL SYMBOL LEGEND <br />NOTE: ALL SYMBOLS MAY NOT BE USED ON THIS PROJECT <br />HOMERUN TO PANELBOARD, NO. OF ARROWS INDICATE <br />NO. OF CIRCUITS <br />CONDUIT CONCEALED IN WALL, IN SLAB ABOVE, OR ABOVE CEILING <br />CONDUIT CONCEALED IN OR BELOW FLOOR OR UNDERGROUND <br />CONDUIT RUN EXPOSED, RUN PARALLEL OR PERPENDICULAR <br />TO STRUCTURE OR WALL <br />CIRCUITING CONTINUED ON ANOTHER SHEET <br />Ju I t: <br />)PPER CASE LETTER ADJACENT TO LUMINAIRE DENOTES TYPE <br />.OWER CASE LETTER ADJACENT TO LUMINAIRE DENOTES SWITCHING <br />a® A <br />RECESSED -MOUNTED LUMINAIRE <br />O A <br />CEILING —MOUNTED LUMINAIRE <br />I-Q A <br />WALL —MOUNTED LUMINAIRE <br />A <br />2'x4' FLUORESCENT LUMINAIRE, CEILING —MOUNTED <br />A <br />F <br />2'x2' FLUORESCENT LUMINAIRE, CEILING -MOUNTED <br />L <br />"NL' INDICATES LUMINAIRE ON UNSWITCHED NIGHT LIGHT CIRCUIT <br />�--i A <br />FLUORESCENT STRIP LUMINAIRE <br />FLUORESCENT LUMINAIRE, WALL -MOUNTED <br />A <br />EMERGENCY BATTERY PACK LUMINAIRE <br />�X ®X <br />EXIT LIGHTS, PROVIDE ARROWS AS REQUIRED <br />A <br />EXTERIOR LUMINAIRE AND POLE <br />IV <br />TRACK LIGHTING <br />SINGLE -POLE SWITCH, 48" AFF <br />$3 <br />THREE-WAY SWITCH, 48" AFF <br />$4 <br />FOUR-WAY SWITCH, 48" AFF <br />$D <br />DIMMING SWITCH, 48" AFF <br />$P <br />SINGLE -POLE SWITCH WITH PILOT LIGHT, 48" AFF <br />$F <br />FAN SPEED CONTROL SWITCH - LUTRON <br />MOTION SWITCH <br />® <br /># DENOTES # OF BUTTONS <br />XX <br />DETAIL CALL -OUT <br />XX <br />TOP NUMBER IS DETAIL NUMBER, BOTTOM <br />NUMBER IS WHERE DETAIL IS LOCATED <br />[FAC'PI <br />FIRE ALARM CONTROL PANEL <br />FIRE ALARM MANUAL PULL STATION <br />0 <br />SMOKE DETECTOR <br />FOQ <br />FIRE ALARM HORN/STROBE <br />SD <br />DUCT -MOUNTED SMOKE DETECTOR <br />TS <br />TAMPER SWITCH <br />FS <br />FLOW SWITCH <br />GROUND PER NEC <br />ELECTRIC METER AND CABINET <br />FLUSH- OR SURFACE -MOUNTED PANELBOARD <br />n MOLDED CASE CIRCUIT BREAKER <br />JO JUNCTION BOX <br />20A, 125V DUPLEX RECEPTACLE 5-20R <br />TWO 20A, 125V, 3W DUPLEX RECEPTACLE, MOUNTED 18" AFF <br />20A, 125V, 3W DUPLEX ISOLATED GROUND, RECEPTACLE MOUNTED <br />SIG 18" AFF <br />TWO 20A, 125V, 3W DUPLEX ISOLATED GROUND, 5-20R MOUNTED <br />SIG 18" AFF <br />20A, 125V, 3W DUPLEX RECEPTACLE, MOUNTED 48" AFF OR 2" <br />ABOVE COUNTER, AS REQUIRED <br />20A, 125V, 3W SIMPLEX RECEPTACLE, MOUNTED 18" AFF <br />20A, 125V, <br />3W <br />DUPLEX <br />RECEPTACLE IN FLUSH <br />FLOOR BOX <br />20A, 125V, <br />3W <br />DUPLEX <br />ISOLATED -GROUND RECEPTACLE IN FLUSH <br />® IG <br />FLOOR BOX <br />20A, 125V, <br />3W <br />DUPLEX <br />CLEAN POWER RECEPTACLE, MOUNTED <br />18" AFF <br />20A, 125V, <br />3W <br />DUPLEX <br />CLEAN POWER RECEPTACLE, MOUNTED <br />48" AFF OR <br />2" <br />ABOVE <br />COUNTER, AS REQUIRED <br />® <br />20A, 125V, 3W DUPLEX CLEAN POWER RECEPTACLE <br />IN FLUSH FLOOR BOX <br />20A <br />TWIST -LOCK RECEPTACLE L5-20R, PLUG L5-20P 20A 125V. <br />Q <br />CORD #12. <br />20A <br />TWIST -LOCK RECEPTACLE 1_1 1-20R, PLUG L1 1-20P 20A 250V 30. <br />CORD #12. <br />30A <br />TWIST -LOCK RECEPTACLE L5-30R, PLUG L5-30P 30A 125V. <br />CORD #10. <br />30A <br />TWIST -LOCK RECEPTACLE L6-30R, PLUG L6-30P 30A 250V. <br />Q <br />CORD # 10. <br />50A <br />TWIST -LOCK RECEPTACLE L15-50R, PLUG L15-50P 50A 250V <br />Q <br />30. CORD #6. <br />60A <br />TWIST -LOCK RECEPTACLE L15-60R, PLUG L15-60P 60A 250V <br />30. CORD #4. <br />XX/X/X <br />DISCONNECT SWITCH, XX/XX/X DENOTES AMPERAGE, FUSE AND <br />POLES <br />MECHANICAL EQUIPMENT CALLOUT, INCLUDES DISCONNECT BY EC, <br />GE) <br />AS REQUIRED BY NEC <br />XX <br />C� <br />ELECTRIC MOTOR <br />EO <br />EQUIPMENT CONNECTION POINT <br />® <br />RELAY <br />(-QS <br />WALL -MOUNTED SPEAKER <br />QS <br />CEILING -MOUNTED SPEAKER <br />TELEPHONE OUTLET <br />GENERAL NOTES <br />1. ALL WORK SHALL BE IN ACCORDANCE WITH THE LATEST NEC, STATE AND <br />LOCAL REQUIREMENTS. <br />2. THE DRAWINGS ARE DIAGRAMMATIC AND THE OMISSION OF AN ITEM <br />NECESSARY FOR THE PROPER FUNCTIONING ON THE SYSTEM DOES NOT <br />RELIEVE THE ELECTRICAL CONTRACTOR FROM SUPPLYING THAT ITEM. <br />3. ALL POWER AND LIGHTING RACEWAY SHALL HAVE A GREEN -GROUND <br />CONDUCTOR. <br />4. COORDINATE ALL ELECTRICAL WORK WITH THAT OF OTHER TRADES PRIOR TO <br />THE INSTALLATION OF THAT WORK. <br />5. ARRANGE ALL INSPECTIONS AND OBTAIN ALL CERTIFICATES REQUIRED BY <br />THE LOCAL CODE ENFORCEMENT AGENCY. <br />6. EC MAY INSTALL MULTIPLE CIRCUITS INDICATED ON PANEL SCHEDULE IN A <br />SINGLE CONDUIT. EC SHALL BE RESPONSIBLE FOR VERIFYING THAT CONDUIT <br />FILL AND CONDUCTOR DERATING MEETS NEC. ON ISOLATED GROUND <br />CIRCUITS, ALL NEUTRALS SHALL BE CONSIDERED A CURRENT -CARRYING <br />CONDUCTOR AND EACH BRANCH CIRCUIT SHALL HAVE A SEPARATE NEUTRAL <br />AND ISOLATED -GROUNDING CONDUCTOR (NO SHARING). <br />7. EC SHALL FIRESTOP ALL ELECTRICAL PENETRATIONS OF FIRE -RATED <br />PARTITIONS (WALLS, FLOORS, OR CEILINGS) WITH AN APPROVED FIRESTOP <br />SYSTEM RATED FOR THE APPLICATION. FIRESTOP SYSTEM SHALL BE <br />UL-LISTED AND INSTALLED IN STRICT COMPLIANCE WITH THE <br />MANUFACTURER'S INSTRUCTIONS. <br />8. ALL EXIT AND EMERGENCY LIGHTS SHALL BE CONNECTED TO THE <br />UNSWITCHED LEG OF THE LOCAL LIGHTING CIRCUIT. <br />9. THE LOCATION AND SIZE OF LOADS SHALL BE CHECKED WITH THE OWNER, <br />ARCHITECT OR APPROPRIATE SUBCONTRACTOR AND ADJUSTMENTS MADE <br />ACCORDINGLY. <br />10. THE DESIGN IS BASED ON THHN/THWN COPPER CONDUCTOR. MINIMUM <br />CONDUCTOR SIZE IS NO. 12 AWG. <br />11. DO NOT SCALE FROM THESE DRAWINGS. REFER TO ARCHITECTURAL PLANS <br />OR FIELD MEASUREMENTS FOR DIMENSIONS. <br />12. EXPOSED INTERIOR CONDUIT IS NOT PERMITTED WITHOUT THE WRITTEN <br />AUTHORIZATION OF THE OWNER. WHEN ALLOWED, SURFACE -MOUNTED <br />RACEWAY SHALL BE WIREMOLD, OR EQUIVALENT METALLIC SURFACE <br />RACEWAY. EC SHALL PROVIDE ALL RACEWAY, BOXES AND FITTINGS REQUIRED <br />FOR A COMPLETE INSTALLATION. WIRING IN NONPUBLIC AREAS MAY BE IN <br />EMT. <br />13. ALL MECHANICAL EQUIPMENT SHALL HAVE A MEANS OF DISCONNECT AS <br />REQUIRED BY NEC. EC SHALL FURNISH AND INSTALL A MOTOR SNAP SWITCH <br />OR DISCONNECT SWITCH, WITH OR WITHOUT FUSES (PER MANUFACTURER'S <br />RECOMMENDATION), WHERE REQUIRED BY CODE. FOR ALL OTHER <br />MECHANICAL/PLUMBING EQUIPMENT. COORDINATE REQUIREMENTS WITH <br />DIVISION 15. <br />14. EC SHALL VERIFY WITH AHJ THE REQUIREMENT FOR SHOW WINDOW LIGHTING <br />AND PROVIDE RECEPTACLES, AS REQUIRED. <br />15. COORDINATE ELECTRICAL SERVICE REQUIREMENTS WITH LOCAL UTILITY <br />COMPANY. PROVIDE ALL CONSTRUCTION IN COMPLIANCE WITH UTILITY <br />COMPANY REQUIREMENTS. <br />16. PRIOR TO ROUGH IN, EC SHALL VERIFY ELECTRICAL REQUIREMENTS FOR ALL <br />KITCHEN EQUIPMENT AND COORDINATE RECEPTACLE LOCATION WITH <br />SUPPLIED EQUIPMENT. EC SHALL PROVIDE PROPER RECEPTACLE, CORD AND <br />PLUG FOR ALL EQUIPMENT SHOWN ON THE KITCHEN EQUIPMENT SCHEDULE. <br />17. ALL 120V, 15- AND 20-AMP RECEPTACLES IN THE KITCHEN, BAR AND <br />SERVICE AREAS SHALL BE GFCI RECEPTACLES. IN COMPLIANCE WITH NEC <br />210.8. <br />18. EC SHALL VERIFY ELECTRICAL REQUIREMENTS FOR WALK-IN COOLER AND <br />WALK-IN FREEZER PRIOR TO ROUGH IN AND MAKE ADJUSTMENTS, AS <br />REQUIRED, WITH NO ADDITIONAL COST TO OWNER. EC SHALL PROVIDE ALL <br />POWER AND CONTROL WIRING AND RACEWAY, AS REQUIRED, FOR A FULLY <br />OPERATIONAL WALK-IN COOLER AND WALK-IN FREEZER, INCLUDING LIGHTS, <br />HEATERS, SENSORS AND REFRIGERATION SYSTEMS. <br />19. SHUNT -TRIP BREAKER FEEDING PANEL K3 SHALL BE ACTIVATED BY THE <br />ANSUL SYSTEM. <br />20. EC TO PROVIDE BOX AND CONDUIT FOR ALL DATA AND TELEVISION OUTLETS. <br />ALL DATA AND TELEVISION CABLING AND DEVICES TO BE FURNISHED AND <br />INSTALLED BY OTHERS. <br />21. MOTION SWITCH TO BE SENSORSWITCH WSD-W OR EQUIVALENT. <br />22. FAN SPEED CONTROL SWITCH TO BE LUTRON NTFS-I2E-WH. <br />23. FLOOR BOX TO BE WALKER 880CS1-1 WITH BRASS FLANGE AND COVER <br />PLATE. <br />24. ALL PANELS AND DISCONNECT SWITCHES SHALL BE SQUARE D, NO <br />EXCEPTIONS. <br />25. ALL LIGHT FIXTURES TO BE AS SHOWN ON THE LIGHTING FIXTURE <br />SCHEDULE, NO EXCEPTIONS. <br />26. LIGHTING CONTROL SYSTEM SHALL BE LUTRON, NO EXCEPTIONS. <br />27. ROOF TOP UNITS TO SHUT DOWN UPON ACTIVATION OF THE DUCT SMOKE <br />DETECTOR. EC SHALL WIRE AS NECESSARY AND COORDINATE WITH <br />MECHANICAL. <br />28. SOUND SYSTEM, INCLUDING SPEAKERS AND WIRING, TO BE FURNISHED AND <br />INSTALLED BY OTHERS. <br />29. SYSTEM TERMINAL BOARD TO BE MOUNTED IN A 24"Wx36" Hx6" D <br />FLUSH -MOUNTED ENCLOSURE WITH LOCKING DOOR. <br />30. BREAKERS IN PANEL MDP FEEDING DOWNSTREAM PANELS SHALL BE <br />SELECTED TO SERIES RATE TO ALLOW 10K AIC BRANCH BREAKERS IN THE <br />DOWNSTREAM PANELS. <br />�D DATA OUTLET <br />c� <br />�v TELEVISION OUTLET <br />DICKENS & ASSOCIATES, INC. <br />232 Bay Street Phone: (386) 253-1511 <br />Daytona Beach, FL 32114 Fax: (386) 252-0673 <br />CA #: 002396 Project #: 4542.00 <br />Engineer: Stephen Byrne PE #: 17584 <br />u <br />L <br />O <br />> <br />•L <br />C: <br />0 <br />0� <br />c <br />�c <br />c <br />0 <br />0 <br />Q <br />0 <br />UZ) <br />u <br />.:.c <br />L <br />0 <br />LO LO O <br />,o <br />0000CN <br />r_�. rl�QQ <br />00 <br />v v <br />c <br />O `'- <br />a. <br />O <br />00 <br />D C%I <br />cY) <br />0 <br />a) O <br />c .} <br />0 <br />-0 �0 <br />c <br />L 0 <br />LO c=i, O <br />C <br />C Co <br />Lo <br />a <br />a <br />N cr- <br />(D copyright <br />C7 <br />CV <br />L0 <br />C Y) <br />L M <br />0 0 <br />> <br />a) . <br />L <br />O O <br />vi <br />� s <br />'O >` <br />O s <br />'O C1 <br />revisions: <br />I <br />i <br />drawn: <br />slb <br />checked: <br />spb <br />date: <br />3-21-08 <br />prof. no: <br />P07-15B <br />E 0.02 <br />