Laserfiche WebLink
II I I 1 1 II 11 it <br />SECTION 09500 <br />LAY - IN CEILINGS <br />PART ONE - GENERAL <br />1.01 SCOPE <br />FURNISH LABOR, EQUIPMENT, AND MATERIALS TO COMPLETE THE INSTALLATION OF <br />ALL LAY -IN CEILING MATERIALS AND SUSPENSION SYSTEMS, <br />1.01 SUBMITTALS <br />COMPLY WITH SECTION 10750, SUBMIT SAMPLES FOR APPROVAL, <br />1.02 JOB CONDITIONS <br />NO WORK IS TO BE STARTED UNTIL ALL EXTERIOR OPENINGS ARE CLOSED IN, <br />ALL WET WORK SHALL BE COMPLETED AND DRIED BEFORE WORK IS STARTED, <br />PART TWO - MATERIALS <br />2.01 CEILING PANELS <br />COLOR, TYPE, PATTERN, SIZE, ETC., AS SCHEDULED AND SHOWN ON THE <br />DRAWINGS, EXPOSED GRID SUSPENSION SYSTEM, CHICAGO METALLIC NO. 200 <br />SERIES SNAP GRID SYSTEM WITH WALL <br />ANGELS, NO, 1409, L❑-GLOSS WHITE BAKED ENAMEL PAINT FINISH. <br />PART THREE - EXECUTION <br />3.01 INSTALLATION <br />IN STRICT ACCORDANCE WITH MANUFACTURER'S PRINTED INSTRUCTION, SUSPEND <br />MAIN TEES FROM STRUCTURE USING NO, 9 GAUGE WIRE HANGERS AT 48' CENTER. <br />LOCK CROSS TEES IN PLACE AT EVERY INTERSECTION WITH MAIN RUNNERS, AND <br />WALL ANGLES WITH ENDS OF TEES RESTING ON BOTTOM FLANGE, SECURE WALL <br />ANGLES TO SUBSTRATE WITH SUITABLE FASTENERS AND ANCHORS, SUPPORT ALL <br />LAY- IN UNITS ON ALL FOR SIDES, PROVIDE EXTRA HANGERS IF REQUIRED. <br />SUSPEND SURFACE MOUNTED FIXTURES FROM BUILDING STRUCTURE <br />AND PULL TIGHTLY AGAINST CEILING. COORDINATE WITH THE ELECTRICAL <br />CONTRACTOR REGARDING SUSPENSION OF ELECTRICAL CEILING FIXTURES FROM THE <br />CEILING SUSPENSION. <br />3.02 CLEAN-UP <br />AT COMPLETION OF THE WORK, REMOVE ALL SCAFFOLDING, CONTAINERS AND <br />OTHER RUBBISH FROM THIS PORTION OF THE WORK FROM THE SITE. LEAVE ALL <br />TILE SUPPORTING MEMBERS FIRMLY AND SECURELY ANCHORED, FREE OF FINGER <br />MARKS OR SMUDGES AND IN PERFECT CONDITION. <br />DIVISION 10 SPECIALTIES <br />SECTION 10260 <br />CORNER GUARDS CIF REQUIRED PER DRAWINGS) <br />PART ONE - GENERAL <br />1.01 GENERAL <br />FURNISH LABOR, EQUIPMENT, AND MATERIALS TO COMPLETE THE INSTALLATION OF <br />ALL RUBBER OR VINYL CORNER GUARDS, <br />1.01 SUBMITTALS <br />COMPLY WITH SECTION 10750, SUBMIT SAMPLES FOR APPROVAL. <br />PART TWO - MATERIALS <br />2.01 CORNER GUARDS <br />A. APPROXIMATE SIZE SHALL BE 2' X 2' FULL HEIGHT. COLOR SHALL BE <br />WHITE OR CLEAR TO MATCH ADJACENT WALL FINISHES. VERIFY COLOR WITH <br />CONSTRUCTION MANAGER. <br />B. PROVIDE RUBBER OR VINYL CORNER GUARDS BY ONE OF THE FOLLOWING <br />MANUFACTURERS OR OWNER APPROVED SUBSTITUTIONS. <br />1. JOHNSONITE - MIDDLEFIELD, OHI❑ (216-543-8916) <br />2. ROPPE - FOSTORIA, ❑HIO (419-435-8546) <br />3. RC MUSSON RUBBER CO., - AKRON, OHI❑ (216-773-7651) <br />4. MERCER PRODUCTS COMPANY, INC., - ❑RLANDO, FLORIDA (407-578-2900) <br />C. PROVIDE STAINLESS STEEL CORNER GUARDS CIF REQUIRED PER DRAWINGS) <br />BY ONE MANUFACTURER'S ALIKE AND AS FOLLOWS, PROVIDE APPROXIMATELY <br />2' X 2' BY FULL WALL HEIGHT STAINLESS STEEL CORNER GUARDS AT <br />L❑CATION S AS SHOWN ON THE DRAWINGS BY ONE OF THE FOLLOWING <br />MANUFACTURERS OR OWNER APPROVED SUBSTITUTIONS, <br />1, K.J. MILLER CORPORATION, ELKHARD, IN (800-34-7584) <br />2. PAWLING CORPORATION, PAWLING, NY (914-855-1005) <br />3. AMERICAN FLOOR PRODUCTS CO., INC. ROCKVILLE, MD (800-342-0424) <br />4. MCKINNEY/PARKER DIVISION, SCRANTON, PA (717-348-7551) OR <br />(415-282-7800) <br />PART THREE - EXECUTION <br />3.01 GENERAL <br />INSTALL CORNER GUARDS WHERE NOTED ON THE DRAWINGS AND PER <br />MANUFACTURER'S WRITTEN INSTRUCTIONS. <br />SECTION 10290 <br />PEST CONTROL <br />PART ONE - GENERAL <br />1.01 SCOPE <br />FURNISH LABOR, EQUIPMENT AND MATERIALS TO COMPLETE THE APPLICATION OF <br />INSECTICIDE. <br />1.02 SUBMITTALS <br />COMPLY WITH SECTION 10750, SUBMIT SAMPLES FOR APPROVAL. <br />PART TWO - MATERIALS <br />2.01 PEST CONTROL PRODUCT <br />PERMA-DUST PT240 BORIC - ACID- BASED INSECTICIDE BY WHITMIRE <br />RESEARCH LABORATORIES INC., ST. LOUIS, MO (314-225-5713), OR OWNER <br />APPROVED SUBSTITUTION, <br />PART THREE - EXECUTION <br />3.01 GENERAL <br />APPLY AT THE RATE OF 150 SQUARE FEET PER 20 ❑Z., AEROSOL CAN TO FLAT <br />SIDES OF STUDS OF PERIMETER WALLS, INSIDE OF PERIMETER WALL SHEATHING <br />TOP SIDE OF GYPSUM BOARD CEILING MATERIAL AND ALL OTHER AREAS CIF ANY) <br />INDICATED ON THE DRAWINGS. APPLY JUST PRIOR TO COVERING OR ENCLOSING. <br />APPLY IN STRICT CONFORMANCE WITH MANUFACTURERS RECOMMENDATIONS. <br />SECTION 10310 <br />TILE BACKER BOARD <br />PART ONE - GENERAL <br />1.01 SCOPE <br />FURNISH LABOR, EQUIPMENT, AND MATERIALS TO COMPLETE THE INSTALLATION OF <br />CEMENTI❑US TILE BACKER BOARD <br />1.02 SUBMITTALS <br />COMPLY WITH SECTION 10750, SUBMIT SAMPLES FOR APPROVAL, <br />PART TWO - MATERIALS <br />2.01 CEMENTIOUS TILE BACKER BOARD <br />DUROCK CEMENT BOARD - 5/8' THICK - UNITED STATES GYPSUM COMPANY, <br />P.O. BOX 806278, CHICAGO, IL 60680-4124. <br />PART THREE - EXECUTION <br />3.01 GENERAL <br />APPLY IN LOCATIONS AS DIRECTED IN SECTIONS AND DETAILS. USE POSITIVE <br />ATTACHMENT OF BUGLE HEAD DRYWALL SCREWS, <br />EXTERIOR SIGNAGE (IF REQUIRED PER DRAWINGS) <br />SECTION 10430 <br />EXTERIOR SIGNAGE <br />PART ONE - GENERAL <br />1.01 SCOPE <br />FURNISH LABOR, EQUIPMENT, AND MATERIALS TO COMPLETE THE INSTALLATION <br />OF ALL EXTERIOR SIGNAGE. <br />PART TWO - MATERIALS <br />2.01 EXTERIOR SIGNAGE <br />A. OWNER SHALL SUPPLY ALL EXTERIOR SIGNAGE. CONTRACTOR SHALL <br />INSTALL EXTERIOR SIGNAGE PER MANUFACTURER'S INSTALLATION <br />INSTRUCTIONS. <br />B. CONTRACTOR SHALL COORDINATE ELECTRICAL INSTALLATION AND FINAL <br />ELECTRICAL CONNECTIONS FOR EXTERIOR SIGNAGE UNLESS OTHERWISE <br />INDICATED. <br />SECTION 10440 <br />INTERIOR SIGNAGE <br />CIF REQUIRED PER DRAWINGS) <br />PART ONE - GENERAL <br />1.01 SCOPE <br />FURNISH LABOR, EQUIPMENT, AND MATERIALS TO COMPLETE THE INSTALLATION <br />OF ALL INTERIOR SIGNAGE, <br />PART TWO - MATERIALS <br />2.01 INTERIOR SIGNAGE <br />A. OWNER SHALL SUPPLY ALL INTERIOR SIGNAGE, CONTRACTOR SHALL <br />INSTALL INTERIOR SIGNAGE PER MANUFACTURER'S INSTALLATION <br />INSTRUCTIONS. <br />B. CONTRACTOR SHALL SUPPLY AND INSTALL ALL REQUIRED BLOCKING IN <br />WALLS AS REQUIRED. <br />C. CONTRACTOR SHALL COORDINATE ELECTRICAL INSTALLATION AND FINAL <br />ELECTRICAL CONNECTIONS FOR INTERIOR SIGNAGE UNLESS ❑THERWISE <br />INDICATED. <br />SECTION 10520 <br />FIRE EXTINGUISHERS <br />PART ONE - GENERAL <br />1.01 SCOPE <br />FURNISH LABOR, EQUIPMENT, AND MATERIALS TO COMPLETE THE INSTALLATION <br />OF ALL FIRE EXTINGUISHERS. <br />PART TWO - MATERIALS <br />2.01 FIRE EXTINGUISHERS <br />A. FIRE EXTINGUISHERS SHALL BE MULTIPURPOSE DRY CHEMICAL TYPE RATE <br />4-A, 60-BC, 10LB. NOMINAL CAPACITY] IN ENAMELED STEEL CONTAINER, <br />FOR CLASS A, CLASS B AND CLASS C FIRES. PROVIDE MANUFACTURER'S <br />STANDARD BRACKET FOR EXTINGUISHER UL AND FM LISTED UNIT AS <br />MANUFACTURED BY ONE OF THE FOLLOWING, <br />1. J.L. INDUSTRIES <br />2. LARSEN'S MANUFACTURING COMPANY <br />3. MUCKLE MANUFACTURING DIVISION OF TECHNICO, INC. <br />4, PROFILE INTERNATIONAL, INC, <br />5, BADGER <br />PART THREE - EXECUTION <br />3.01 GENERAL <br />CONTRACTOR SHALL INSTALL FIRE EXTINGUISHERS AS INDICATED ON THE <br />DRAWINGS OR IF NOT INDICATED ON THE DRAWINGS, AS DIRECTING BY THE <br />LOCAL FIRE MARSHAL TO COMPLY WITH APPLICABLE GOVERNING REGULATIONS. <br />SECTION 10800 <br />TOILET ACCESSORIES <br />PART ONE - GENERAL <br />1.01 SCOPE <br />THE WORK IN THIS SECTION INCLUDES ACCESSORIES IN TOILETS. <br />PART TWO - MATERIALS <br />2.01 ACCESSORIES <br />PR❑VIDE TOILET ACCESSORIES TO MEET AMERICANS WITH DISABILITIES ACT <br />ACCESSIBILITY GUIDELINES (ADAAG) AS SHOWN ON THE DRAWINGS AND OR <br />OWNER APPROVED SUBSTITUTIONS. <br />PART THREE - EXECUTION <br />3.01 INSTALLATION <br />ERECT ITEMS IN A RIGID SUBSTANTIAL MANNER, IN CORRECT POSITIONS, AND <br />LEVEL & PLUM. FULLY TRIM IN WHERE REQUIRED. INSTALL TOILET <br />ACCESSORIES PER ADAAG GUIDELINES. <br />DIVISION 11 - EQUIPMENT <br />SECTION 11400 <br />FOOD SERVICE EQUIPMENT <br />PART ONE - GENERAL <br />1.01 SCOPE <br />A. WHERE FIXED FOOD SERVICE EQUIPMENT ABUTS OTHER EQUIPMENT OR <br />CONSTRUCTION, SEAL RESULTING JOINT TO MAKE IT SANITARY FOR <br />CLEANING PURPOSES, PROVIDE BACKER ROD WHEN REQUIRED. USE ONLY <br />RTV ADHESIVE/SEALANT APPROVED BY NSF <br />1. SILASTIC 732 DOW CORNING CORPORATION, MIDLAND, MI <br />(517-496-6000) FOR USE IN FOOD ZONES, PRODUCTS MEETING THIS <br />REQUIREMENT INCLUDE THE <br />2. SILITE DEVC❑N CORPORATION, DANVERS, MA (617-777-1100) <br />FOLL❑WING, <br />3. RTV100-SERIES, GENERAL ELECTRIC COMPANY, WATERFORD, NY <br />(518-266-2315) <br />B. CLEAN AND PRIME OR SPOT PRIME SURFACES TO RECEIVE SEALANT AS <br />REQUIRED. COLOR TO BE CLEAR OR TO MATCH ADJACENT SURFACES, <br />C. ITEMS REQUIRING SEALANT INCLUDE, BUT ARE NOT LIMITED TO, THE <br />FOLLOWING, <br />1. MOP SINK <br />2. THREE COMPARTMENT SINK <br />3. PREP SINK <br />4. HAND SINKS <br />5. INSIDE AND OUTSIDE WALK-IN COOLER <br />6. EXHAUST HOOD <br />DIVISION 12 - FURNISHINGS <br />(NOT USED) <br />DIVISION 13 - SPECIAL CONSTRUCTION <br />(NOT USED) <br />DIVISION 14 - CONVEYING SYSTEMS <br />(NOT USED) <br />DIVISION 15 - MECHANICAL <br />(SEE MECHANICAL DRAWINGS) <br />DIVISION 16 - ELECTRICAL <br />(SEE ELECTRICAL DRAWINGS) <br />U8 <br />N <br />N <br />0 <br />y <br />o <br />00 <br />J <br />c <br />�' <br />JU. <br />o <br />� <br />� <br />o <br />N <br />t0 <br />♦ ^ N <br />� <br />CC <br />C <br />� <br />o <br />¢ <br />O <br />r <br />o_ <br />0 <br />JM <br />J <br />LL <br />rn <br />0 <br />a� <br />Ua <br />> o <br />O r <br />Lo <br />o <br />z <br />o <br />c <br />� <br />a <br />c <br />N <br />J <br />C <br />J <br />O Q <br />y <br />o <br />J <br />ti <br />L <br />U <br />C <br />CC <br />t` <br />0 <br />0 <br />N <br />J�04 <br />J > <br />cci <br />W W <br />o <br />.J <br />N Q D LL, <br />O <br />a. m J <br />�_-CLJ <br />J = <br />w <br />U <br />="_ <br />a <br />U <br />WOOw <br />NCDN <br />Revisions: <br />W <br />Z <br />060 <br />Q <br />� U <br />LL <br />O _ <br />ZU <br />W <br />CL <br />W <br />Project Number <br />07059 <br />Date <br />02-28-08 <br />Sheet Number <br />G1.4 <br />