Laserfiche WebLink
EXTERIOR WALL BASE DETAIL <br />SCALEd/2'=1'-0' <br />STEPPED FOOTING DETAIL <br />SCALEd/2'=1'-0' <br />GLAV. MTL. FLASHING W/ STND, 8' C.M.U. <br />WEEP HOLES @ 24' D.C. CONST. W/ <br />HORIZ, REINF. @ <br />16' D.C. & 1-#5 <br />VERT, IN <br />0'-0' II FILLED CELL @ <br />FINISH FLOOR 4'-0' ❑,C, MAX, <br />FILL SOLID <br />WITH GROUT <br />TERMITE <br />4' THICK CONC, SLAB TREATED <br />REINFORCED W/ WWF COMPACTED <br />6X6-W1,4XW1,4 S❑IL <br />20'X12' CONC, FTG, _ J <br />REINF, W/ 2-#5 • <br />BOTTOM, TYP, <br />6 9/161 11'-1 1/4'1 1 6 3/16' <br />9 EXT, WALL BASE @ VENEER <br />S--2 SCALEd/2'=1'-0' <br />('-2"'�STOREFRONT BASE <br />S J-2 SCALEd/2'=1'-0' <br />BY OTHERS <br />SIDEWALK <br />#4t=- <br />_ _- -- <br />F❑R C❑NTIN, <br />SEE WALL SECTIONS <br />3 SECTION AT ENTRY <br />S - Z SCALEd/2'=1'-0' <br />NOTE, FOR ROOFING & FLASHING DETAILS <br />P,T.(1)-2XS PLATE <br />REFER TO ARCH. DWGS, <br />W/1 DIA.X9' <br />ANCHOR BOLTS <br />CONT,L2X2X1/8 <br />SP,@ 4'-0'O,C. <br />J <br />(WELD DECK @ 6'O.C.) <br />GROUT FILLED <br />KNOCKOUT BLK, <br />W/2-#4 CONT, <br />EL.+18'-0' <br />EL.+13-4' Cu <br />3/16 1 1/2 <br />CONT,L4X3X1/4 <br />W/5/ 'DIA,EXP,BOLTS <br />cu <br />�� <br />EL.+15'-4' <br />SP.@ 24'0,C,(3'EMBED.) <br />(WELD DECK @ 6'O.CJ <br />JOIST BEARING <br />I• 'K' JOIST <br />• <br />CONC,7IE BEAM <br />M <br />- <br />oe <br />8'X16' <br />W/2-#4 T&B <br />I EMBED PL. <br />#3 TIES @ 24'O.C. <br />CON(. TIE BEAM <br />"X4`X3/ ' �\ <br />W/2-1/2'X6' <br />8'X24' W/2-#4 <br />STUDS <br />T&B #3 TIES @ <br />�� SP,@ 5'O.C, <br />24' D.C. (POCKET <br />GROUT BLK,S LID <br />- - <br />BEAM 4'XS' AT <br />AT EXP,BOLTS <br />JOIST LOCATIONS) <br />I., <br />CONT.HORIZ,BRIDGING <br />WALL REINAT FIRST PANEL POINT <br />WALL REINF, <br />/4X <br />W/2-5/8DIA.EXP .BOL S <br />HK,10' INTO <br />HK.10' @ <br />SP,@ 6'0,C.(3'EMBED,) <br />Ill TIE BEAM <br />PARAPET <br />AT JOIST BRIDGING LINES <br />"6 JOIST BEARING AT FRONT WALL <br />S-2 SCALEi1/2'=1'-0' <br />PAINTED <br />K JOIST <br />-- 7"`" @ END 3 PANELS <br />7 ROOF CONSTRUCTION DETAIL <br />S-2J SCALE4/2'=1'-0' <br />#4 T <br />CONT. <br />- - - - - - <br />- - - <br />//\/ <br />o\�/\\�% <br />I I <br />4 SIDEWALK EDGE DETAIL <br />S - Z SCALEi1/2'=1'-0' <br />NOTE, FOR ROOFING & FLASHING DETAILS <br />REFER TO ARCH, DWGS. <br />P,T,(1)-2X8 PLATE <br />W 2'DIA,) 9' <br />ANCHOR BOLTS <br />SP,@ 4'-0'O.C. <br />cu <br />EL.+14'-B' <br />N <br />JOIST BEARING <br />EMBED PL, <br />B'X4'X3/8' <br />W/2-1/2'X6' <br />AI)STUDS <br />SP.@ 5'O.C. <br />WALL REINF. <br />W/2-#4 T&B <br />#3 TIES @ 24'O.C, <br />POCKET BEAM 4'X8' <br />AT JOIST LOCATIONS <br />HK,10' INTO <br />TIE BEAM <br />CONT.L2X2X1/8 <br />WELD TO JOISTS <br />(WELD DECK @ 6'❑.C.) <br />16 4 1/2 <br />'K' JOIST <br />CONT.HORIZ. <br />g JOIST BEARING AT REAR WALL <br />S-2 SCALE4/2'=1'-0' <br />STRUCTURAL NOTES & SPECIFICATIONS <br />SITE PREPARATION <br />1. STRIP AND GRUB ALL VEGETATION, DEBRIS, AND OTHER DELETERI❑US <br />MATERIAL WITHIN THE STRUCTURE FOOTPRINT PLUS A MARGIN OF 5 FEET, <br />2. THE CLEARED SURFACE SHALL BE PROF ROLLED USING APPROPRIATE <br />COMPACTION EQUIPMENT FOR SITE AND SOIL CONDITIONS, SUFFICIENT PASSES <br />SHALL BE MADE TO DEVELOP A MINIMUM DRY DENSITY OF 95% OF THE <br />MODIFIED PROCTOR MAXIMUM DRY DENSITY (ASTM D-1557) TO A DEPTH OF <br />24 INCHES BELOW THE COMPACTED SURFACE, <br />3. AFTER COMPLETION OF PROOF ROLLING, APPROVED CLEAN FILL MATERIAL <br />SHALL BE ADDED AS REQUIRED IN LEVEL LIFTS NOT EXCEEDING 12 INCHES <br />IN UNCOMPACTED THICKNESS. EACH LIFT SHALL BE COMPACTED TO ACHIEVE <br />AT LEAST 95% OF THE MODIFIED PROCTOR MAXIMUM DRY DENSITY (ASTM D- <br />1557). FILLING AND COMPACTION SHALL CONTINUE UNTIL FINAL GRADE <br />ELEVATIONS ARE ATTAINED. <br />4, EXCAVATE FOR COLUMN AND WALL FOOTINGS TO THE SPECIFIED ELEVATIONS <br />AND VERIFY IN PLACE COMPACTION, COMPACT EXCAVATED SUBGRADE BEARING <br />SURFACES AS REQUIRED TO ACHIEVE A MINIMUM DRY DENSITY OF 95% OF <br />THE MODIFIED PROCTOR MAXIMUM DRY DENSITY (ASTM D-1557) TO A MINIMUM <br />DEPTH OF 12 INCHES BELOW BOTTOM OF F❑❑TINGS. <br />5, ALL PREPARED AND COMPACTED AREAS SHALL BE OBSERVED AND TESTED BY <br />A REPRESENTATIVE OF A CERTIFIED GE❑TECHNICAL ENGINEER, <br />FOUNDATION NOTES <br />1. ALL FOOTINGS SHALL BEAR ON CONTROLLED COMPACTED SUBGRADE HAVING A <br />MINIMUM BEARING CAPACITY OF 2500 POUNDS PER SQUARE FOOT, <br />2, MAXIMUM SLOPE BETWEEN BOTTOMS OF FOOTINGS SHALL BE ONE VERTICAL TO <br />TWO HORIZONTAL, <br />3, CONSTRUCTION JOINTS IN WALLS OR GRADE BEAMS SHALL BE VERTICAL JOINTS <br />LOCATED A MINIMUM DISTANCE OF 4'-0' FROM ANY WALL OPENING AND <br />APPROXIMATELY MIDWAY BETWEEN COLUMNS OR SUPPORTS. <br />4. NO BACKFILLING AGAINST WALLS SHALL BE DONE UNTIL CONCRETE HAS <br />ATTAINED FULL STRENGTH AND SUPPORTING FLOORS ARE IN PLACE OR WALLS <br />HAVE BEEN ADEQUATELY BRACED, <br />5, SLABS ON GRADE SHALL BE PLACED ON CONTROLLED COMPACTED FILL DENSIFIED <br />TO NOT LESS THAN 95% OF THE MODIFIED PROCTOR MAXIMUM DRY DENSITY, <br />ASTM D 1557, <br />6, PROVIDE CONTRACTION CONTROL JOINTS IN SLABS ON GRADE AT DESIGNATED <br />LOCATIONS SHOWN ON PLAN. <br />7, FOR LOCATION OF FINISH DEPRESSIONS IN SLABS ON GRADE, IF APPLICABLE, <br />REFER TO ARCHITECTURAL DRAWINGS, <br />CONCRETE NOTES <br />1. ALL CONCRETE WORK SHALL CONFORM TO THE ACI BUILDING CODE (318-99). <br />2, ALL CONCRETE SHALL BE 3000 PSI CONTROLLED NORMAL WEIGHT CONCRETE <br />UNLESS OTHERWISE NOTED ON DRAWINGS, <br />3, ALL REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60, <br />4, WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185. <br />5. CONCRETE COVERING FOR REINFORCING STEEL SHALL BE A MINIMUM OF 3/4, <br />FOR SLABS, 1 1/2' FOR BEAMS AND COLUMNS, 1 1/2' FOR FORMED SURFACES <br />EXPOSED TO EARTH OR WEATHER, 3' FOR FOOTINGS AND BEAMS CAST AGAINST <br />AND PERMANENTLY EXPOSED TO EARTH, <br />6, CONTRACTOR SHALL VERIFY SIZE AND L❑CATION OF ALL OPENINGS WITH <br />ARCHITECTURAL AND MECHANICAL DRAWINGS. OPENINGS NOT SHOWN ON <br />STRUCTURAL DRAWINGS SHALL BE SUBMITTED T❑ THE STRUCTURAL ENGINEER <br />FOR APPROVAL. <br />7, ALL REINFORCING BARS MARKED CONTINUOUS SHALL BE LAPPED 43 BAR <br />DIAMETERS. LAP TOP BARS AT MIDSPAN AND BOTTOM BARS AT SUPPORTS <br />UNLESS OTHERWISE NOTED, HOOK ALL TOP BARS AT DISCONTINUOUS ENDS. <br />STRUCTURAL STEEL NOTES <br />1. ALL STRUCTURAL STEEL SHALL CONFORM TO ASTM A572, GRADE 50 UNLESS <br />OTHERWISE NOTED, STEEL PIPE COLUMNS SHALL CONFORM TO ASTM A53, <br />TYPE S, GRADE B, STEEL TUBING SHALL CONFORM TO ASTM A500, GRADE B <br />(Fy = 46 KSI), <br />2, DETAILING, FABRICATION AND ERECTION OF STEEL SHALL CONFORM TO THE <br />MANUAL OF STEEL CONSTRUCTION (9TH ED.)(ALLOWABLE STRESS DESIGN). <br />3, ALL SHOP CONNECTIONS SHALL BE WELDED OR HIGH STRENGTH BOLTED. <br />4. ALL WELDING SHALL CONFORM TO THE AMERICAN WELDING SOCIETY,AWS <br />D1,1 STRUCTURAL WELDING CODE -STEEL, <br />5. FIELD CONNECTIONS SHALL BE MADE WITH ASTM A325N HIGH STRENGTH BOLTS <br />UNLESS OTHERWISE NOTED ON DRAWINGS. <br />6. BEAM CONNECTIONS SHALL BE ADEQUATE TO SUPPORT ONE HALF THE TOTAL <br />UNIFORM LOAD CAPACITY FOR THE GIVEN SIZE AND SPAN OF BEAM, ALL <br />BOLTS SHALL BE A MINIMUM OF 3/4' DIAMETER. <br />7, ALL STEEL SHALL RECEIVE A SHOP COAT OF PAINT EXCEPT CONTACT SURFACES <br />OF SLIP CRITICAL HIGH STRENGTH BOLTS AND SURFACES TO BE WELDED, <br />STEEL JOIST NOTES <br />1, DESIGN, FABRICATION, AND ERECTION OF OPEN WEB STEEL JOISTS SHALL <br />CONFORM TO STEEL JOIST INSTITUTE'S STANDARD SPECIFICATIONS, <br />ROOF JOIST DESIGN SHALL BE MODIFIED AS REQUIRED TO PROVIDE A NET <br />UPLIFT LOAD CAPACITY ❑F 25 PSF, JOIST MANUFACTURER SHALL SUBMIT <br />AFFADAVIT BY A FLORIDA LICENSED PROFESSIONAL ENGINEER CERTIFYING <br />CONFORMANCE WITH DESIGN LOAD CRITERIA, <br />2, PROVIDE TOP AND BOTTOM CHORD JOIST BRIDGING SIZED AND SPACED TO <br />MEET THE STEEL J❑IST INSTITUTE SPECIFICATIONS MODIFIED AS REQUIRED <br />BY UPLIFT DESIGN, USE HORIZONTAL BRIDGING THROUGHOUT EXCEPT THAT <br />DIAGONAL CROSS BRIDGING SHALL BE COMBINED WITH HORIZONTAL BRIDGING <br />AT THREE CONSECUTIVE PANELS ADJOINING EXTERIOR WALLS, ALL BRIDGING <br />AND BRIDGING ANCHORS SHALL BE COMPLETELY INSTALLED BEFORE <br />CONSTRUCTION LOADS ARE PLACED ON JOISTS. <br />3, CONCENTRATED HANGER LOADS, SUCH AS HEAVY PIPES, MECHANICAL <br />EQUIPMENT, ETC„ NOT SHOWN ON DRAWINGS, WILL NOT BE PERMITTED <br />WITHOUT PRIOR APPROVAL OF THE STRUCTURAL ENGINEER. SUCH LOADS <br />IF PERMITTED, SHALL BE SUPPORTED AT JOIST TOP CHORD PANEL PONTS, <br />MASONRY NOTES <br />1, ALL MASONRY CONSTRUCTION SHALL BE IN ACCORDANCE WITH ACI 530-99/ <br />A,S.C.E. 5-99/TMS 402-99 AND ACI 530.1-99/A,S,C.E, 6-99/TMS 602-99, <br />2, ALL CONCRETE MASONRY SHALL BE NORMAL WEIGHT UNITS CONFORMING To <br />ASTM C90. TYPE N-II WITH A MINIMUM MASONRY COMPRESSIVE STRENGTH, <br />f'M = 1500 PSI AT 28 DAYS, <br />3. MORTAR SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 1800 PSI AND <br />SHALL CONFORM TO ASTM C270, TYPE S, <br />4, COARSE GROUT SHALL HAVE A 3/8' MAXIMUM SIZE AGGREGATE AND A <br />MINIMUM COMPRESSIVE STRENGTH OF 2000 PSI. SLUMP MEASURED IN <br />ACCORDANCE WITH ASTM C143 SHALL RANGE BETWEEN 8' AND 11'. <br />5, PROVIDE VERTICAL REINFORCING AS SHOWN ON DRAWINGS. DOWEL ALL <br />VERTICAL BARS INTO FOOTINGS, LAP BARS 48 DIAMETERS AT SPLICE <br />LOCATIONS, AND HOOK BARS INTO TIE BEAM AT ROOF LEVEL, <br />6, PROVIDE GROUT FILLED KNOCKOUT BLOCKS AT LOCATIONS INDICATED <br />WALL SECTIONS, LAP ALL BARS 48 DIAMETERS AT SPLICE LOCATIONS, <br />7, FILL BLOCK WALLS SOLID WITH COARSE GROUT AT ALL REINFORCED CELLS <br />AND AT DESIGNATED LOCATIONS SHOWN ON DRAWINGS, MORTAR ALL CROSS <br />WEBS OF CELLS RECEIVING GROUT AND MAINTAIN 3' MINIMUM CLEAR CELL <br />OPENINGS AND MINIMUM CLEAR AREA OF 10 SQ.IN, <br />B. FOR HIGH LIFT GROUTING, PR❑VIDE CLEANOUT OPENINGS AT BOTTOM OF <br />ALL GROUT FILLED CELLS (ALTERNATE CELLS AT SOLID GROUTED WALLS). <br />9, HORIZONTAL JOINT REINFORCING SHALL BE STANDARD WEIGHT, LADDER TYPE <br />REINFORCING CONSISTING OF #9 GAGE LONGITUDINAL AND TRANSVERSE RODS <br />SPACED AT VERTICAL INTERVALS NOT EXCEEDING 16'O.C. CROSS RODS TO <br />BE SPACED 16'0,C, LAP LONGITUDINAL RODS AT LEAST 8' AT SPLICE <br />L❑CATIONS, <br />10.PROVIDE PRECAST CONCRETE LINTEL BEAMS OVER ALL EXTERIOR AND INTERIOR <br />MASONRY WALL OPENINGS UNLESS OTHERWISE NOTED. TOTAL LOAD DEFLECTION <br />NOT TO EXCEED L/360, <br />ILPR❑VI➢E TEMPORARY BRACING OF MASONRY WALLS AS REQUIRED DURING <br />CONSTRUCTION. <br />LIVE LOADS <br />FLAT ROOF 20 PSF <br />WIND LOADS (FLORIDA BUILDING QQDE 2004) <br />BASIC WIND SPEED = 130 MPH <br />FLAT ROOF <br />IMPORTANCE FACTOR, II = 1.0 <br />EXPOSURE B <br />INTERNAL PRESSURE COOEFICIENT t0,18 ✓� <br />MAIN FRAME END ZONE, 2a = 11.0' <br />COMPONENTS & CLADDING END ZONE, a = 5.5' <br />MAIN WIND FORCE RESISTING SYSTEM PER A,S.C.E, 7-02 <br />HEIGHT (FT) HORIZ.WIND PRESSURE(INT,ZONE) HORIZ.WIND PRESSURE(END ZONE) <br />0-30 15,9 PSF 23,9 PSF <br />COMP❑NENTS AND CLADDING - EFFECTIVE WIND AREA C 10 SF, <br />HEIGHT (FT) H❑RIZ,WIND PRESSURE(INT,ZONE) HORIZ.WIND PRESSURE(END ZONE) <br />0-30 +24,8/-26,9 PSF +24.8/-33,1 PSF <br />HEIGHT (FT,) VERTICAL WIND PRESSURE AT ROOF a <br />0-30 ZONE 1 +11.0/-27.1 PSF <br />ZONE 2 +11.0/-45.5 PSF a F21 <br />ZONE 3 +11.0/-68.5 PSF <br />OVERHANG <br />ZONE 2 -39.1 PSF <br />ZONE 3 -64,4 PSF <br />PLUS AND MINUS SIGNS SIGNIFY PRESSURES ACTING TOWARD AND AWAY FROM THE <br />SURFACES RESPECTIVELY, <br />ti <br />T <br />rO <br />\, <br />o Q <br />8 <br />U� <br />rn <br />$ <br />v <br />J <br />rn <br />C <br />M <br />U- <br />d <br />O <br />@ <br />C <br />V♦ N <br />c <br />� <br />Q <br />o <br />c <br />o <br />JLL <br />M <br />M <br />J <br />0 <br />Lb <br />U� <br />a <br />> o <br />o" <br />LO <br />cn <br />0 <br />z <br />co <br />v <br />c <br />Q <br />J <br />oLL <br />U <br />G <br />J <br />O <br />U. <br />U <br />C <br />m <br />0 <br />r` <br />CN <br />N <br />04 <br />� J � o to <br />LL -1 <br />o > M <br />z U ¢W-J.. <br />0 J zpcn <br />F- Or �mJ <br />Z Q <br />O m (D= _ <br />w CL M 0- <br />z N �UJ <br />N <br />Revisions: <br />Project Number <br />E: 06082a <br />Date <br />03-19-07 <br />Sheet Number <br />S-2 <br />i <br />i' <br />