E
<br />A
<br />C
<br />B
<br />t:
<br />A
<br />C1
<br />1 2 3 4 5 6
<br />HOSP- HOSP. STAIR;
<br />NOT AN
<br />ELEV ELEV s� ;4 WAITING �--s MECH OFFICE
<br />S 4 S - 4- EXIT 2222 2223 2003 O ICU #13
<br />2213
<br />1
<br />S
<br />0
<br />i
<br />sus N/S
<br />[]SUB
<br />2213A
<br />CORRIDOR
<br />(III)0 2000 r 1 3 4 O5 �JJ�'J I 4 3 1
<br />13 PCU #16
<br />z i TLT - 2251 f
<br />z 1 2251 10 T
<br />J 0
<br />]ICNM
<br />w n '
<br />a N
<br />1' 18
<br />Cr
<br />12
<br />a i TL 10 . _ ..
<br />22526 ,
<br />13 PCU #1
<br />!(13
<br />2252
<br />�►,
<br />1 PCU #14
<br />TLT 13 2253
<br />2253 10
<br />O/ zv
<br />I mN��
<br />1 I8
<br />12
<br />TL i o
<br />22546
<br />13 PCU #1
<br />2254
<br />1
<br />i 1;
<br />PCU #1
<br />13 -
<br />i TLT 2255
<br />2255 10
<br />1 N F 1
<br />LO
<br />1 ,CM
<br />+NNE
<br />i I8
<br />12
<br />TL 10
<br />1 22566 PCU #1
<br />13 2256
<br />- - ---
<br />1 o PCU
<br />CORRIDOR
<br />2250 1
<br />f T T
<br />SUB N/S 8 2
<br />2257A
<br />ISO PCU PCU #9
<br />#10 2258
<br />2257 /'--
<br />"`� TLT iLT'
<br />2257E 2258E
<br />PLAN - LVL 2 - PCU AREA - DEMOLITION
<br />1/8" = V-0"
<br />ICU #14
<br />r 2214
<br />CONF. OFFICE F E PCU #1 8
<br />T� 2272 2273 22ss 1
<br />O 8 266E
<br />Z�10
<br />i
<br />J ����,N
<br />I+/ 6
<br />�\� 7 STAFF J s
<br />O I LOUNGE 1
<br />2267 9 p)
<br />MECH. I 1, ,r _
<br />227, I 8 '! TLT 1
<br />_ \,_f 2265E O
<br />PCs #2 8
<br />EQUIP ® 1
<br />_ = EVS PCU #3
<br />i BLOOD 22s8A 22s4 TL,T
<br />GAS , o 8) % 2264
<br />2270 11 r 1 U)11 1
<br />Z<IO
<br />8 ` OFFICE
<br />PYXI 22ss U) —_—_
<br />o
<br />TLT 9 1 1`
<br />50C
<br />„ 8 !'
<br />TLT 0
<br />8 PCU #4 ' 22 $B 1
<br />—t
<br />SUB N/S 9 PCU #5
<br />2259A _ _ 2262` TLT 1
<br />2262E
<br />11 O -zz �z_ 80 11 N¢ 11 i
<br />PCU #8 ISO PCU 11 O Z� O I I w
<br />2259 N I �I -� M
<br />a #7 1
<br />2260 N ~
<br />�
<br />9 pt
<br />cc
<br />0 f TLTTL
<br />l a
<br />TLT I 2261 B
<br />2259E 8 2260B PCU #6 0 I w
<br />8 O 80 2261 l a
<br />O
<br />STAIR;
<br />HOSP- HOSP. NOT AN
<br />ELEV ELEV ,EXIT S_*_ WAITING 1—•-s MECH OFFICE ICU #13
<br />S-- 1 S - 4 2222 2223 2003 S
<br />CO 2213
<br />1 �S4---s�—Ts S4- —./ I n UB A
<br />2213
<br />ZP II
<br />CORRIDOR
<br />200o WT MT 11 '
<br />2001 -11 11 2002 _ _ _ — _ _ _ _< 8 ICU #14
<br />8 8 , r N ` / 2214 -
<br />� 2001-A 2002-A
<br />Ln o LO PCU #1
<br />7 PCU #16Z225t_ 8 ,1 N �/ io 10 8 N CONE. OFFICE ® ®266-A� 22ss , 7 TLT
<br />w' TLT 10 2251 A 8 2 2 A 0 22 -B 2 I 1
<br />J 2251B s 9 11 11 8 11 8 6 N I 2266B
<br />N 1, Z' SUPPLIES 11 Z¢ a Q
<br />CM
<br />N M
<br />W ._cD a W 1 a 4 I N 1
<br />— — — — — 1 I 22s7 A STAFF
<br />N B to
<br />1 TLT I 22
<br />2252E
<br />7 ��PCU #1'51 5 A�
<br />(0 10 2252 8 11 11 8
<br />I
<br />® I 11 8
<br />7 PCU #14% e „
<br />TLT 10 2253 53 q ( 22
<br />2253B
<br />i 11 Z I 6 9
<br />�N
<br />I
<br />m 8 y
<br />I I
<br />TLT Al
<br />22546 7 PCU #13,,2254-A 8 11 ( A-301
<br />'Q 10 2254
<br />— — — — — —
<br />---+-„�
<br />1�- 7 PCU #12 s 11
<br />` 22 2255-
<br />TLT 10 55 A
<br />2255B
<br />11 Z < 6 9
<br />a
<br />i --F
<br />Y
<br />i N„ ;
<br />I 8�
<br />TLT n
<br />` 2256'
<br />2256E 7 PCU #11� A 8 11
<br />10 2256 _
<br />2275-A MECH Q ¢
<br />/ 2275 I LOUNGE i
<br />N N 2267 N
<br />a 1 2271-A ( 4
<br />s MECH. I 1
<br />11 2271 �
<br />3 I TLT
<br />75A- IT EQUIP 11 I 1 L/ 226g_q i i 7 2265E
<br />2275A 2279 8 IT 2268 AA PCU #2
<br />2279-A _ s EQUIP
<br />TLT 10 WORK 22ss D ® \ ,
<br />76A-A 2276A RM BLOO EVS 22s8A-A `: / PCU #3 7
<br />0 2250E
<br />= GAS 2268A 2264-A 1 ®� TLT
<br />V� 5 I 2264B
<br />¢ N o 2270 ® Z¢ 1 0
<br />OFFICE N 2270-A
<br />Q
<br />�N 8
<br />2276 N 0 �$
<br />8 a Z TLT N 4
<br />11 11 2250c TELEM R
<br />LZ "
<br />PYXI
<br />226 1
<br />227 �ad \ 6- ¢
<br />N 0) 4 w
<br />00 i j) r 8 N (a)�.'� CM
<br />COMMAND 11 N IPCU 3 1
<br />5Q TLT 3
<br />CTR C RIDOR 2263-q , 2263B
<br />33 2250D 2250 8 PCU 7 #4
<br />�D 2263IV
<br />8 QSUB N 8 �Q SUB 3 ® PCU #5 7
<br />2257 N 2259 2262_A I 2262 , TLT
<br />® ® 9 3 5 I 2262B 1
<br />i � o IO
<br />Q
<br />_ ' Om
<br />Aw
<br />ISO PCU PCU #9 PCU #80 4 4 0 ISO PCU Z ¢ ® 4 C14N z
<br />#10 2258 I 2259 #7 N 1 i
<br />2257 1 2260 N ' �_
<br />— - — - — - - — - — - -- (%% I J
<br />i N H
<br />7 10 .y 1 10 7 7 703 1LU
<br />11 8 A 8 11 2260 / y m ' ` � a
<br />22578 2258E-q 22598-A A 8 � I TLT C
<br />TLT- TLT TLT TLT 1 22s1 B <
<br />2257B 2258E - 22596 2260B PCU #6 7 I ¢
<br />IN e a
<br />%JIrMn L.
<br />0
<br />PLAN - LVL 2 - PCU AREA - NEW WORK
<br />C4
<br />PARTIAL PROJECT LIMIT LINE
<br />PAT. RM. I
<br />221s
<br />I 10 I
<br />1
<br />IPAT. RM.
<br />2215
<br />TLT i
<br />'- 13
<br />i Fo o$
<br />PUBLf I
<br />ELEV
<br />6'- 2
<br />1 /8" = V-0"
<br />BASE BID AND ALTERNATE NOTES #03:
<br />THE NOTES INCLUDED HEREIN ARE FOR PCU PHASE 2- SEE PLANS &
<br />KEYNOTES.
<br />BASE BID:
<br />A. NOTED EXISTING DOOR LEAVES IN PCU PHASE 2 SHALL REMAIN
<br />AS EXISTING WITHOUT REFINISHING OR RESTAINING.
<br />B. NOTED EXISTING DOOR HARDWARE SHALL REMAIN.
<br />C. NOTED EXISTING DOOR FRAMES IN PCU PHASE 2 SHALL RECEIVE
<br />NEW PAINT FINISH.
<br />a. PROVIDE ALL LABOR AND MATERIALS TO REPAIR NOTED
<br />EXISTING DOOR FRAMES VIA "BONDO" OR OTHER METHOD.
<br />b. PROVIDE ALL LABOR AND MATERIALS TO PREP AND PAINT
<br />NOTED DOOR FRAMES IN PCU PHASE 2. SEE FINISH
<br />SCHEDULE.
<br />ALTERNATE #03:
<br />A. NOTED EXISTING DOOR LEAVES AND FRAMES IN PCU PHASE 2 TO
<br />BE REFINISHED.
<br />a. PROVIDE LABOR AND MATERIALS AS A "PER UNIT COST" LINE
<br />ITEM REPRESENTING THE COST FOR THE WORK PER DOOR.
<br />• PROVIDE ALL LABOR AND MATERIALS TO REMOVE
<br />EXISTING DOOR LEAF FINISH.
<br />• PROVIDE ALL LABOR AND MATERIALS TO REFINISH DOOR
<br />LEAVES AS REQUIRED ON SHEET A-501.
<br />• PROVIDE ALL LABOR AND MATERIALS TO PREP AND PAINT
<br />NOTED DOOR FRAMES IN PCU PHASE 2 BEYOND THAT
<br />INCLUDED WITHIN BASE BID. SEE FINISH SCHEDULE.
<br />• PROVIDE LABOR AND MATERIALS FOR INSTALLATION OF
<br />KICK PLATE- SEE NOTES ON A-501 DOOR SCHEDULE
<br />SHEET AND WALL PROTECTION FINISH SCHEDULE
<br />BASE BID AND ALTERNATE NOTES #04:
<br />THE NOTES INCLUDED HEREIN ARE FOR PCU PHASE 2- SEE PLANS &
<br />KEYNOTES.
<br />BASE BID:
<br />A. EXISTING FLOORING AND WALL FINISH IN CONF RM 2272 & OFFICE
<br />2273 SHALL REMAIN AND BE PROTECTED THRU CONSTRUCTION
<br />ALTERNATE #04:
<br />A. EXISTING FLOORING AND WALL FINISHES IN CONF RM 2272 &
<br />OFFICE 2273 SHALL BE REMOVED AND NEW FINISHES APPLIED.
<br />a. PROVIDE ALL LABOR AND MATERIALS TO REMOVE EXISTING
<br />FLOOR FINISH WITHIN ROOMS AND PREPARE FLOOR SLAB TO
<br />RECEIVE NEW FLOORING.
<br />B. NEW FLOORING TO BE INSTALLED IN CONF RM 2272 AND OFFICE
<br />2273.
<br />a. PROVIDE ALL LABOR AND MATERIALS TO INSTALL NEW
<br />FLOORING, INCLUDING WALL BASE, WITHIN CONK RM 2272
<br />AND OFFICE 2273. SEE FLOOR FINISH PLAN & SCHEDULE.
<br />C. CONF RM 2272 & OFFICE 2273 TO RECEIVE NEW PAINT FINISH.
<br />a. PROVIDE ALL LABOR AND MATERIALS TO PREP AND PAINT
<br />ALL WALLS IN CONF 2272 & OFFICE 2273, SEE WALL FINISH
<br />PLAN & SCHEDULE
<br />PARTIAL PROJECT LIMIT LINE
<br />PAT. RM.
<br />I
<br />22,s_
<br />G
<br />f 22
<br />1
<br />i
<br />1
<br />PAT. RM.
<br />I
<br />2215
<br />J TLT 2215A-A
<br />I
<br />22,5A
<br />i
<br />PUBLIC O
<br />KEYED NOTES - DEMOLITION
<br />O FOR DURATION OF CONSTRUCTION, CONTRACTOR
<br />SHALL ERECT TEMPORARY ICRA PARTITIONS AND
<br />BARRIERS, AS REQUIRED, TO SEPARATE THE
<br />CONSTRUCTION AREA FROM ADJACENT OCCUPIED
<br />SPACES/AREAS. DOORS WITHIN ICRA BARRIERS
<br />SHALL INCLUDE, AS MINIMUM, A 45-MINUTE FIRE -
<br />RATED DOOR, SELF -CLOSING & POSITIVE LATCHING
<br />HARDWARE, AND LOCKING MECHANISM. SEE DETAIL
<br />FOR TEMPORARY ICRA BARRIER REQUIREMENTS.
<br />DURING CONSTRUCTION, CONTRACTOR SHALL
<br />LOCATE TEMPORARY 10LB TYPE ABC FIRE
<br />EXTINGUISHER WITHIN WORK AREA.
<br />0 DURING CONSTRUCTION, CONTRACTOR SHALL
<br />LOCATE HEPA FILTER NEGATIVE AIR MACHINE(S) TO
<br />NEGATIVELY PRESSURIZE CONSTRUCTION AREA.
<br />40 CONTRACTOR SHALL LOCATE WALK -OFF MATS AT
<br />ALL ENTRY/EXIT POINTS TO CONSTRUCTION AREA
<br />TO PREVENT MIGRATION OF DUST & DEBRIS
<br />OUTSIDE OF CONSTRUCTION AREA. CONTRACTOR
<br />TO ENSURE THAT CORRIDOR SPACE OUTSIDE OF
<br />ENTRY POINT TO KEPT CLEAN OF DUST VIA
<br />MOPPING, AS REQUIRED.
<br />�5 EXISTING SPACE TO REMAIN ACTIVE FOR THE
<br />DURATION OF CONSTRUCTION. CONTRACTOR TO
<br />KEEP SPACE FREE OF DEBRIS AND OBSTRUCTIONS
<br />TO MAINTAIN EGRESS PATH.
<br />LOCATION AND CONSTRUCTION OF ICRA BARRIER
<br />SHALL NOT INTERFERE WITH OPERATION OR
<br />CLOSURE OF EXISTING CROSS -CORRIDOR DOORS.
<br />ROOM NOT IN SCOPE. NO DEMOLITION WORK OR
<br />NEW CONSTRUCTION WITHIN THIS SPACE.
<br />O EXISTING MILLWORK & PLUMBING FIXTURES TO BE
<br />DEMOLISHED AND REMOVED
<br />Q EXISTING SUB -NURSE STATIONS AT PCU PATIENT
<br />ROOMS INCLUDE EXISTING OBSERVATION
<br />WINDOWS W/ MAGNET -CONTROLLED INTEGRAL
<br />BLINDS. SEE BASE BID AND ALTERNATE #1 NOTES
<br />FOR SCOPE OF REMOVING AND REPLACING
<br />EXISTING WINDOWS.
<br />10 WITHIN SPACE, CONTRACTOR TO DEMOLISH AND
<br />REMOVE EXISTING FLOORING AND WALL FINISHES.
<br />PREP EXISTING FLOOR SLAB & WALL SURFACES TO
<br />RECEIVE NEW FINISH. EXISTING MILLWORK,
<br />CEILINGS, SOFFITS, WALL PROTECTION
<br />COMPONENTS, AND OTHER DEVICES TO REMAIN,
<br />U.N.O.
<br />11 CONTRACTOR TO DEMOLISH AND REMOVE
<br />EXISTING WALL PROTECTION, CORNER GUARDS,
<br />HANDRAILS, ETC. PREPARE EXISTING WALL TO
<br />RECEIVE NEW WALL PROTECTION COMPONENTS AS
<br />REQUIRED. SEE NEW WORK AND EQUIPMENT PLANS
<br />12 PCU PHASE 2: SEE BASE BID AND ALTERNATE #01
<br />FOR CASEWORK SCOPE IN THIS ROOM/SPACE.
<br />13 PCU PHASE 2: SEE BASE BID AND ALTERNATE #02
<br />FOR FINISH AND FIXTURE SCOPE IN THIS TLT RM.
<br />14 PCU PHASE 2: SEE BASE BID AND ALTERNATE #04
<br />FOR FINISH SCOPE WITHIN THIS ROOM/SPACE,
<br />BASE BID AND ALTERNATE NOTES #01:
<br />THE NOTES INCLUDED HEREIN ARE FOR PCU PHASE 2- SEE PLANS &
<br />KEYNOTES.
<br />BASE BID:
<br />A. EXISTING CASEWORK WITHIN NOTED SPACES/ AREAS OF PCU
<br />PHASE 2 SHALL REMAIN AS EXISTING AND NOT BE DEMOLISHED.
<br />a. SUB -NURSE STATIONS, COMMAND CENTERS, MEDS, AND
<br />NOURISH ROOMS IN PCU PHASE 2. SEE DEMOLITION PLAN.
<br />b. PROVIDE ALL LABOR AND MATERIALS TO PROTECT (IN
<br />PLACE) EXISTING CASEWORK FROM DAMAGE DURING
<br />CONSTRUCTION.
<br />B. NEW FLOORING IS TO BE INSTALLED TO THE EDGE OF THE
<br />EXISTING CASEWORK.
<br />ALTERNATE #01:
<br />A. EXISTING CASEWORK WITHIN NOTED SPACES/ AREAS SHALL BE
<br />DEMOLISHED AND REMOVED.
<br />a. SUB -NURSE STATIONS, COMMAND CENTERS, MEDS, AND
<br />NOURISH ROOMS IN PCU PHASE 2. SEE DEMOLITION PLAN.
<br />b. PROVIDE ALL LABOR AND MATERIALS TO DEMOLISH AND
<br />REMOVE EXISTING CASEWORK AT AREAS LISTED ABOVE. SEE
<br />DEMOLITION PLAN KEYED NOTES,
<br />B. INSTALL NEW CASEWORK AND ASSOCIATED CEILING SOFFITS AS
<br />SHOWN IN NEW EQUIPMENT PLAN, ELEVATIONS, AND DETAILS.
<br />a. PROVIDE ALL LABOR AND MATERIALS FOR FABRICATION AND
<br />INSTALLATION OF NEW CASEWORK FOR NOTED SPACES.
<br />C. NEW FLOORING TO BE INSTALLED UNDER NEW CASEWORK, NOT
<br />FINISHED TO IT.
<br />a. PROVIDE ALL LABOR AND MATERIALS FOR INSTALLATION OF
<br />NEW FLOORING UNDER NEW CASEWORK BEYOND THAT
<br />INCLUDED WITHIN BASE BID.
<br />BASE BID AND ALTERNATE NOTES #02:
<br />THE NOTES INCLUDED HEREIN ARE FOR PCU PHASE 2- SEE PLANS &
<br />KEYNOTES.
<br />BASE BID:
<br />A. EXISTING TILE FLOOR & WALL FINISHES WITHIN NOTED PCU
<br />PHASE 2 TOILET ROOMS TO REMAIN. TLT ACCESSORIES FOR
<br />NOTED TLT RMS TO REMAIN.
<br />a. PCU PATIENT TLT RMS, SEMI -PRIVATE PATIENT ROOM TLT
<br />RM, AND PUBLIC TLTS 2001, 2002 ,& 2276A.
<br />b. PROVIDE ALL LABOR AND MATERIALS TO PREPARE EXISTING
<br />GYPSUM -FACED WALLS WITHIN ABOVE NOTED SPACES TO
<br />RECEIVE NEW EPDXY PAINT (SEE FINISH SCHEDULE).
<br />c. PROVIDE ALL LABOR AND MATERIALS TO APPLY NEW EPXOY
<br />PAINT TO GYPSUM WALLS IN ABOVE LISTED SPACES. SEE
<br />FINISH PLAN AND KEYNOTES LEGEND.
<br />d. PROVIDE ALL LABOR AND MATERIALS TO PREPARE & INSTALL
<br />NEW OFOI TLT ACCESSORIES (DISPENSERS) WITHIN NOTED
<br />TLT ROOMS. SEE EQUIPMENT PLAN.
<br />ALTERNATE #02:
<br />A. EXISTING TILE FLOOR AND WALL FINISH AT NOTED PCU PHASE 2
<br />TOILET ROOMS SHALL BE DEMOLISHED AND REMOVED.
<br />a. PCU PATIENT TLT RMS, SEMI -PRIVATE PATIENT ROOM TLT
<br />RM, AND PUBLIC TLTS 2001, 2002 ,& 2276A
<br />b. PROVIDE ALL LABOR AND MATERIALS TO REMOVE EXISTING
<br />FLOOR AND WALL TILE IN ROOMS LISTED ABOVE AND PREP
<br />FOR NEW FINISHES.
<br />B. INSTALL NEW FLOOR AND WALL (TILE & PAINT) FINISHES IN PCU
<br />PHASE 2 TOILET ROOMS. SEE FLOOR AND WALL FINISH PLANS
<br />FOR FINISHES TO BE INSTALLED.
<br />a. PROVIDE ALL LABOR AND MATERIALS TO INSTALL NEW WALL
<br />TILE TO BE INSTALLED ON WET WALLS. SEE FINISH PLAN &
<br />FINISH SCHEDULE.
<br />b. PROVIDE ALL LABOR AND MATERIALS (EPDXY PAINT) TO
<br />PAINT ON NON -WET WALLS IN THE SPACES LISTED ABOVE.
<br />SEE FINISH PLAN & FINISH SCHEDULE.
<br />c. PROVIDE ALL LABOR AND MATERIALS TO INSTALL NEW
<br />FLOOR TILE. SEE FINISH PLAN & FINISH SCHEDULE.
<br />d. PROVIDE ALL LABOR AND MATERIALS TO INSTALL NEW CFCI,
<br />OFCI, & OFCRI TLT ACCESSORIES (GRAB BARS, MIRROR,
<br />ETC.) IN NOTED TOILET ROOMS. SEE EQUIP PLAN
<br />e. PROVIDE SEPARATE LINE ITEMS FOR FLOOR AND WALL TILE.
<br />PLAN - LVL 2 - PCU - SEMI-PRIV. PAT RM - NEW WORK
<br />1 HOUR FIRE
<br />—-5—♦S—*-S_ 1 HOUR FIRE/ SMOKE BARRIER
<br />2 HOUR FIRE
<br />-��-S--♦5--��5-- 2 HOUR FIRE/ SMOKE BARRIER
<br />—�T—♦T TEMPORARY 1 HOUR FIRE
<br />S—S— SMOKE BARRIER
<br />-5-----5---�-c- "GRAY" = EXISTING RATING
<br />TO REMAIN
<br />PARTITIONS:
<br />EXISTING/REMAINING
<br />NEW WORK
<br />C = _ DEMOLISHED
<br />GENERAL NOTES:
<br />DEMOLITION
<br />1. LIGHT LINES INDICATE EXISTING
<br />CONSTRUCTION TO REMAIN.
<br />2. REMOVE ALL EXISTING CONSTRUCTION
<br />INDICATED BY BOLD DASHED LINES.
<br />3. REFER TO APH-101 SHEET FOR ADDITIONAL
<br />PHASING AND PLAN INFORMATION
<br />GENERAL NOTES:
<br />NEW WORK
<br />1. ALL WALLS ARE TYPE U UNLESS OTHERWISE
<br />NOTED.
<br />2. ALL DIMENSIONS ARE TO FINISH FACE OF
<br />WALLS.
<br />3. REFER TO APH-101 SHEET FOR ADDITIONAL
<br />PHASING AND PLAN INFORMATION
<br />KEYED NOTES: NEW WORK
<br />O
<br />ROOM NOT IN SCOPE. NO DEMOLITION WORK OR
<br />NEW CONSTRUCTION WITHIN THIS SPACE.
<br />(�.J
<br />PATCH & REPAIR EXISTING WALL ASSEMBLY
<br />WHERE EXISTING OR TEMPORARY ELEMENTS
<br />HAVE BEEN REMOVED AND/OR DEMOLISHED.
<br />a
<br />OBSERVATION WINDOW AT SUB NURSE STATION.
<br />EXISTING WINDOW TO BE REMOVED AND
<br />REPLACED W/ NEW OBSERVATION WINDOW. SEE
<br />FINISH SCHEDULE FOR INFORMATION.
<br />INFILL WALL OPENING TO CREATE CONTINUOUS
<br />WALL SURFACE. INFILL WITH METAL STUD &
<br />GYPSUM SYSTEM TO MATCH EXISTING WALL
<br />ASSEMBLY. COORDINATE W/ OTHER PATIENT
<br />ROOM WALL AND HEADWALL WORK.
<br />SEE ENLARGED TYPICAL PLANS AND ELEVATIONS
<br />FOR PCU PATIENT ROOM CASEWORK, CEILINGS,
<br />AND OTHER NOTES & REQUIREMENTS.
<br />Q
<br />SEE ENLARGED TYPICAL PLANS AND ELEVATIONS
<br />FOR SUB -NURSE STATION CASEWORK, CEILINGS,
<br />AND OTHER NOTES & REQUIREMENTS.
<br />70
<br />SEE ENLARGED TYPICAL PLANS FOR PCU PATIENT
<br />ROOM TOILET FIXTURES, CEILINGS, AND OTHER
<br />NOTES & REQUIREMENTS.
<br />EXISTING DOOR TO RECEIVE NEW FINISH. SEE
<br />DOOR SCHEDULES AND NOTES ON A-501.
<br />PCU PHASE 2: SEE BASE BID AND ALTERNATE #01
<br />FOR CASEWORK SCOPE IN THIS ROOM/SPACE.
<br />10
<br />PCU PHASE 2: SEE BASE BID AND ALTERNATE #02
<br />FOR FINISH AND FIXTURE SCOPE IN THIS TLT RM.
<br />11
<br />PCU PHASE 2: SEE BASE BID AND ALTERNATE #03
<br />FOR RE -FINISH SCOPE RELATED TO THIS EXISTING
<br />DOOR.
<br />12
<br />PCU PHASE 2: SEE BASE BID AND ALTERNATE #04
<br />FOR FINISH SCOPE WITHIN THIS ROOM/SPACE.
<br />THIS SHEET RE -ISSUED
<br />IN ITS ENTIRETY
<br />PROJECT
<br />NORTH
<br />E
<br />chapuis design group
<br />arc hitecture.pa
<br />510 VONDERBURG DR. SUITE 216
<br />BRANDON, FL 33511
<br />Tel. 813-667-2340
<br />CGDPA - FL # AA-26003049
<br />PROJECT FOR
<br />ADVENTHEALTH -
<br />ZEPHYRHILLS
<br />PCU REFRESH
<br />7050 Gall Blvd.
<br />Zephyrhills, FL 33541
<br />AdventHealth
<br />AHCA CLIENT CODE / FILE NUMBER: WA
<br />1
<br />1 NOV. 2, 2022
<br />Addendum 2 - Construction Coordination
<br />MARK
<br />DATE
<br />DESCRIPTION
<br />PROJECT NUMBER
<br />042-22-236.01
<br />ORIGINAL ISSUE
<br />AUGUST 26, 2022 -
<br />PROJECT MANAGER
<br />TEC
<br />PROJECT DESIGNER
<br />TEC
<br />PROJECT ARCHITECT
<br />THOMAS E. CHAPUIS - AR97109
<br />B LANDSCAPE ARCHITECT
<br />WA
<br />CIVIL ENGINEER
<br />N/A
<br />STRUCTURAL ENGINEER
<br />N/A
<br />MECHANICAL ENGINEER
<br />TIMOTHY P. PENNOCK - PE54516
<br />ELECTRICAL ENGINEER
<br />CHARLES T. ALEXANDER - PE76422
<br />INTERIOR DESIGNER
<br />CDG
<br />EQUIPMENT PLANNER
<br />WA
<br />DRAWN BY
<br />SDL
<br />PLANS - PCU WING -
<br />DEMOLITION &NEW
<br />A WORK
<br />As indicated
<br />Aml 01
<br />92i
<br />0
<br />N
<br />O
<br />Al
<br />1/8" = V-0"
<br />1 /8" = V-0"
<br />1 2 3 4 5 6
<br />Project Status
<br />II
<br />
|