Laserfiche WebLink
E <br />A <br />C <br />B <br />t: <br />A <br />C1 <br />1 2 3 4 5 6 <br />HOSP- HOSP. STAIR; <br />NOT AN <br />ELEV ELEV s� ;4 WAITING �--s MECH OFFICE <br />S 4 S - 4- EXIT 2222 2223 2003 O ICU #13 <br />2213 <br />1 <br />S <br />0 <br />i <br />sus N/S <br />[]SUB <br />2213A <br />CORRIDOR <br />(III)0 2000 r 1 3 4 O5 �JJ�'J I 4 3 1 <br />13 PCU #16 <br />z i TLT - 2251 f <br />z 1 2251 10 T <br />J 0 <br />]ICNM <br />w n ' <br />a N <br />1' 18 <br />Cr <br />12 <br />a i TL 10 . _ .. <br />22526 , <br />13 PCU #1 <br />!(13 <br />2252 <br />�►, <br />1 PCU #14 <br />TLT 13 2253 <br />2253 10 <br />O/ zv <br />I mN�� <br />1 I8 <br />12 <br />TL i o <br />22546 <br />13 PCU #1 <br />2254 <br />1 <br />i 1; <br />PCU #1 <br />13 - <br />i TLT 2255 <br />2255 10 <br />1 N F 1 <br />LO <br />1 ,CM <br />+NNE <br />i I8 <br />12 <br />TL 10 <br />1 22566 PCU #1 <br />13 2256 <br />- - --- <br />1 o PCU <br />CORRIDOR <br />2250 1 <br />f T T <br />SUB N/S 8 2 <br />2257A <br />ISO PCU PCU #9 <br />#10 2258 <br />2257 /'-- <br />"`� TLT iLT' <br />2257E 2258E <br />PLAN - LVL 2 - PCU AREA - DEMOLITION <br />1/8" = V-0" <br />ICU #14 <br />r 2214 <br />CONF. OFFICE F E PCU #1 8 <br />T� 2272 2273 22ss 1 <br />O 8 266E <br />Z�10 <br />i <br />J ����,N <br />I+/ 6 <br />�\� 7 STAFF J s <br />O I LOUNGE 1 <br />2267 9 p) <br />MECH. I 1, ,r _ <br />227, I 8 '! TLT 1 <br />_ \,_f 2265E O <br />PCs #2 8 <br />EQUIP ® 1 <br />_ = EVS PCU #3 <br />i BLOOD 22s8A 22s4 TL,T <br />GAS , o 8) % 2264 <br />2270 11 r 1 U)11 1 <br />Z<IO <br />8 ` OFFICE <br />PYXI 22ss U) —_—_ <br />o <br />TLT 9 1 1` <br />50C <br />„ 8 !' <br />TLT 0 <br />8 PCU #4 ' 22 $B 1 <br />—t <br />SUB N/S 9 PCU #5 <br />2259A _ _ 2262` TLT 1 <br />2262E <br />11 O -zz �z_ 80 11 N¢ 11 i <br />PCU #8 ISO PCU 11 O Z� O I I w <br />2259 N I �I -� M <br />a #7 1 <br />2260 N ~ <br />� <br />9 pt <br />cc <br />0 f TLTTL <br />l a <br />TLT I 2261 B <br />2259E 8 2260B PCU #6 0 I w <br />8 O 80 2261 l a <br />O <br />STAIR; <br />HOSP- HOSP. NOT AN <br />ELEV ELEV ,EXIT S_*_ WAITING 1—•-s MECH OFFICE ICU #13 <br />S-- 1 S - 4 2222 2223 2003 S <br />CO 2213 <br />1 �S4---s�—Ts S4- —./ I n UB A <br />2213 <br />ZP II <br />CORRIDOR <br />200o WT MT 11 ' <br />2001 -11 11 2002 _ _ _ — _ _ _ _< 8 ICU #14 <br />8 8 , r N ` / 2214 - <br />� 2001-A 2002-A <br />Ln o LO PCU #1 <br />7 PCU #16Z225t_ 8 ,1 N �/ io 10 8 N CONE. OFFICE ® ®266-A� 22ss , 7 TLT <br />w' TLT 10 2251 A 8 2 2 A 0 22 -B 2 I 1 <br />J 2251B s 9 11 11 8 11 8 6 N I 2266B <br />N 1, Z' SUPPLIES 11 Z¢ a Q <br />CM <br />N M <br />W ._cD a W 1 a 4 I N 1 <br />— — — — — 1 I 22s7 A STAFF <br />N B to <br />1 TLT I 22 <br />2252E <br />7 ��PCU #1'51 5 A� <br />(0 10 2252 8 11 11 8 <br />I <br />® I 11 8 <br />7 PCU #14% e „ <br />TLT 10 2253 53 q ( 22 <br />2253B <br />i 11 Z I 6 9 <br />�N <br />I <br />m 8 y <br />I I <br />TLT Al <br />22546 7 PCU #13,,2254-A 8 11 ( A-301 <br />'Q 10 2254 <br />— — — — — — <br />---+-„� <br />1�- 7 PCU #12 s 11 <br />` 22 2255- <br />TLT 10 55 A <br />2255B <br />11 Z < 6 9 <br />a <br />i --F <br />Y <br />i N„ ; <br />I 8� <br />TLT n <br />` 2256' <br />2256E 7 PCU #11� A 8 11 <br />10 2256 _ <br />2275-A MECH Q ¢ <br />/ 2275 I LOUNGE i <br />N N 2267 N <br />a 1 2271-A ( 4 <br />s MECH. I 1 <br />11 2271 � <br />3 I TLT <br />75A- IT EQUIP 11 I 1 L/ 226g_q i i 7 2265E <br />2275A 2279 8 IT 2268 AA PCU #2 <br />2279-A _ s EQUIP <br />TLT 10 WORK 22ss D ® \ , <br />76A-A 2276A RM BLOO EVS 22s8A-A `: / PCU #3 7 <br />0 2250E <br />= GAS 2268A 2264-A 1 ®� TLT <br />V� 5 I 2264B <br />¢ N o 2270 ® Z¢ 1 0 <br />OFFICE N 2270-A <br />Q <br />�N 8 <br />2276 N 0 �$ <br />8 a Z TLT N 4 <br />11 11 2250c TELEM R <br />LZ " <br />PYXI <br />226 1 <br />227 �ad \ 6- ¢ <br />N 0) 4 w <br />00 i j) r 8 N (a)�.'� CM <br />COMMAND 11 N IPCU 3 1 <br />5Q TLT 3 <br />CTR C RIDOR 2263-q , 2263B <br />33 2250D 2250 8 PCU 7 #4 <br />�D 2263IV <br />8 QSUB N 8 �Q SUB 3 ® PCU #5 7 <br />2257 N 2259 2262_A I 2262 , TLT <br />® ® 9 3 5 I 2262B 1 <br />i � o IO <br />Q <br />_ ' Om <br />Aw <br />ISO PCU PCU #9 PCU #80 4 4 0 ISO PCU Z ¢ ® 4 C14N z <br />#10 2258 I 2259 #7 N 1 i <br />2257 1 2260 N ' �_ <br />— - — - — - - — - — - -- (%% I J <br />i N H <br />7 10 .y 1 10 7 7 703 1LU <br />11 8 A 8 11 2260 / y m ' ` � a <br />22578 2258E-q 22598-A A 8 � I TLT C <br />TLT- TLT TLT TLT 1 22s1 B < <br />2257B 2258E - 22596 2260B PCU #6 7 I ¢ <br />IN e a <br />%JIrMn L. <br />0 <br />PLAN - LVL 2 - PCU AREA - NEW WORK <br />C4 <br />PARTIAL PROJECT LIMIT LINE <br />PAT. RM. I <br />221s <br />I 10 I <br />1 <br />IPAT. RM. <br />2215 <br />TLT i <br />'- 13 <br />i Fo o$ <br />PUBLf I <br />ELEV <br />6'- 2 <br />1 /8" = V-0" <br />BASE BID AND ALTERNATE NOTES #03: <br />THE NOTES INCLUDED HEREIN ARE FOR PCU PHASE 2- SEE PLANS & <br />KEYNOTES. <br />BASE BID: <br />A. NOTED EXISTING DOOR LEAVES IN PCU PHASE 2 SHALL REMAIN <br />AS EXISTING WITHOUT REFINISHING OR RESTAINING. <br />B. NOTED EXISTING DOOR HARDWARE SHALL REMAIN. <br />C. NOTED EXISTING DOOR FRAMES IN PCU PHASE 2 SHALL RECEIVE <br />NEW PAINT FINISH. <br />a. PROVIDE ALL LABOR AND MATERIALS TO REPAIR NOTED <br />EXISTING DOOR FRAMES VIA "BONDO" OR OTHER METHOD. <br />b. PROVIDE ALL LABOR AND MATERIALS TO PREP AND PAINT <br />NOTED DOOR FRAMES IN PCU PHASE 2. SEE FINISH <br />SCHEDULE. <br />ALTERNATE #03: <br />A. NOTED EXISTING DOOR LEAVES AND FRAMES IN PCU PHASE 2 TO <br />BE REFINISHED. <br />a. PROVIDE LABOR AND MATERIALS AS A "PER UNIT COST" LINE <br />ITEM REPRESENTING THE COST FOR THE WORK PER DOOR. <br />• PROVIDE ALL LABOR AND MATERIALS TO REMOVE <br />EXISTING DOOR LEAF FINISH. <br />• PROVIDE ALL LABOR AND MATERIALS TO REFINISH DOOR <br />LEAVES AS REQUIRED ON SHEET A-501. <br />• PROVIDE ALL LABOR AND MATERIALS TO PREP AND PAINT <br />NOTED DOOR FRAMES IN PCU PHASE 2 BEYOND THAT <br />INCLUDED WITHIN BASE BID. SEE FINISH SCHEDULE. <br />• PROVIDE LABOR AND MATERIALS FOR INSTALLATION OF <br />KICK PLATE- SEE NOTES ON A-501 DOOR SCHEDULE <br />SHEET AND WALL PROTECTION FINISH SCHEDULE <br />BASE BID AND ALTERNATE NOTES #04: <br />THE NOTES INCLUDED HEREIN ARE FOR PCU PHASE 2- SEE PLANS & <br />KEYNOTES. <br />BASE BID: <br />A. EXISTING FLOORING AND WALL FINISH IN CONF RM 2272 & OFFICE <br />2273 SHALL REMAIN AND BE PROTECTED THRU CONSTRUCTION <br />ALTERNATE #04: <br />A. EXISTING FLOORING AND WALL FINISHES IN CONF RM 2272 & <br />OFFICE 2273 SHALL BE REMOVED AND NEW FINISHES APPLIED. <br />a. PROVIDE ALL LABOR AND MATERIALS TO REMOVE EXISTING <br />FLOOR FINISH WITHIN ROOMS AND PREPARE FLOOR SLAB TO <br />RECEIVE NEW FLOORING. <br />B. NEW FLOORING TO BE INSTALLED IN CONF RM 2272 AND OFFICE <br />2273. <br />a. PROVIDE ALL LABOR AND MATERIALS TO INSTALL NEW <br />FLOORING, INCLUDING WALL BASE, WITHIN CONK RM 2272 <br />AND OFFICE 2273. SEE FLOOR FINISH PLAN & SCHEDULE. <br />C. CONF RM 2272 & OFFICE 2273 TO RECEIVE NEW PAINT FINISH. <br />a. PROVIDE ALL LABOR AND MATERIALS TO PREP AND PAINT <br />ALL WALLS IN CONF 2272 & OFFICE 2273, SEE WALL FINISH <br />PLAN & SCHEDULE <br />PARTIAL PROJECT LIMIT LINE <br />PAT. RM. <br />I <br />22,s_ <br />G <br />f 22 <br />1 <br />i <br />1 <br />PAT. RM. <br />I <br />2215 <br />J TLT 2215A-A <br />I <br />22,5A <br />i <br />PUBLIC O <br />KEYED NOTES - DEMOLITION <br />O FOR DURATION OF CONSTRUCTION, CONTRACTOR <br />SHALL ERECT TEMPORARY ICRA PARTITIONS AND <br />BARRIERS, AS REQUIRED, TO SEPARATE THE <br />CONSTRUCTION AREA FROM ADJACENT OCCUPIED <br />SPACES/AREAS. DOORS WITHIN ICRA BARRIERS <br />SHALL INCLUDE, AS MINIMUM, A 45-MINUTE FIRE - <br />RATED DOOR, SELF -CLOSING & POSITIVE LATCHING <br />HARDWARE, AND LOCKING MECHANISM. SEE DETAIL <br />FOR TEMPORARY ICRA BARRIER REQUIREMENTS. <br />DURING CONSTRUCTION, CONTRACTOR SHALL <br />LOCATE TEMPORARY 10LB TYPE ABC FIRE <br />EXTINGUISHER WITHIN WORK AREA. <br />0 DURING CONSTRUCTION, CONTRACTOR SHALL <br />LOCATE HEPA FILTER NEGATIVE AIR MACHINE(S) TO <br />NEGATIVELY PRESSURIZE CONSTRUCTION AREA. <br />40 CONTRACTOR SHALL LOCATE WALK -OFF MATS AT <br />ALL ENTRY/EXIT POINTS TO CONSTRUCTION AREA <br />TO PREVENT MIGRATION OF DUST & DEBRIS <br />OUTSIDE OF CONSTRUCTION AREA. CONTRACTOR <br />TO ENSURE THAT CORRIDOR SPACE OUTSIDE OF <br />ENTRY POINT TO KEPT CLEAN OF DUST VIA <br />MOPPING, AS REQUIRED. <br />�5 EXISTING SPACE TO REMAIN ACTIVE FOR THE <br />DURATION OF CONSTRUCTION. CONTRACTOR TO <br />KEEP SPACE FREE OF DEBRIS AND OBSTRUCTIONS <br />TO MAINTAIN EGRESS PATH. <br />LOCATION AND CONSTRUCTION OF ICRA BARRIER <br />SHALL NOT INTERFERE WITH OPERATION OR <br />CLOSURE OF EXISTING CROSS -CORRIDOR DOORS. <br />ROOM NOT IN SCOPE. NO DEMOLITION WORK OR <br />NEW CONSTRUCTION WITHIN THIS SPACE. <br />O EXISTING MILLWORK & PLUMBING FIXTURES TO BE <br />DEMOLISHED AND REMOVED <br />Q EXISTING SUB -NURSE STATIONS AT PCU PATIENT <br />ROOMS INCLUDE EXISTING OBSERVATION <br />WINDOWS W/ MAGNET -CONTROLLED INTEGRAL <br />BLINDS. SEE BASE BID AND ALTERNATE #1 NOTES <br />FOR SCOPE OF REMOVING AND REPLACING <br />EXISTING WINDOWS. <br />10 WITHIN SPACE, CONTRACTOR TO DEMOLISH AND <br />REMOVE EXISTING FLOORING AND WALL FINISHES. <br />PREP EXISTING FLOOR SLAB & WALL SURFACES TO <br />RECEIVE NEW FINISH. EXISTING MILLWORK, <br />CEILINGS, SOFFITS, WALL PROTECTION <br />COMPONENTS, AND OTHER DEVICES TO REMAIN, <br />U.N.O. <br />11 CONTRACTOR TO DEMOLISH AND REMOVE <br />EXISTING WALL PROTECTION, CORNER GUARDS, <br />HANDRAILS, ETC. PREPARE EXISTING WALL TO <br />RECEIVE NEW WALL PROTECTION COMPONENTS AS <br />REQUIRED. SEE NEW WORK AND EQUIPMENT PLANS <br />12 PCU PHASE 2: SEE BASE BID AND ALTERNATE #01 <br />FOR CASEWORK SCOPE IN THIS ROOM/SPACE. <br />13 PCU PHASE 2: SEE BASE BID AND ALTERNATE #02 <br />FOR FINISH AND FIXTURE SCOPE IN THIS TLT RM. <br />14 PCU PHASE 2: SEE BASE BID AND ALTERNATE #04 <br />FOR FINISH SCOPE WITHIN THIS ROOM/SPACE, <br />BASE BID AND ALTERNATE NOTES #01: <br />THE NOTES INCLUDED HEREIN ARE FOR PCU PHASE 2- SEE PLANS & <br />KEYNOTES. <br />BASE BID: <br />A. EXISTING CASEWORK WITHIN NOTED SPACES/ AREAS OF PCU <br />PHASE 2 SHALL REMAIN AS EXISTING AND NOT BE DEMOLISHED. <br />a. SUB -NURSE STATIONS, COMMAND CENTERS, MEDS, AND <br />NOURISH ROOMS IN PCU PHASE 2. SEE DEMOLITION PLAN. <br />b. PROVIDE ALL LABOR AND MATERIALS TO PROTECT (IN <br />PLACE) EXISTING CASEWORK FROM DAMAGE DURING <br />CONSTRUCTION. <br />B. NEW FLOORING IS TO BE INSTALLED TO THE EDGE OF THE <br />EXISTING CASEWORK. <br />ALTERNATE #01: <br />A. EXISTING CASEWORK WITHIN NOTED SPACES/ AREAS SHALL BE <br />DEMOLISHED AND REMOVED. <br />a. SUB -NURSE STATIONS, COMMAND CENTERS, MEDS, AND <br />NOURISH ROOMS IN PCU PHASE 2. SEE DEMOLITION PLAN. <br />b. PROVIDE ALL LABOR AND MATERIALS TO DEMOLISH AND <br />REMOVE EXISTING CASEWORK AT AREAS LISTED ABOVE. SEE <br />DEMOLITION PLAN KEYED NOTES, <br />B. INSTALL NEW CASEWORK AND ASSOCIATED CEILING SOFFITS AS <br />SHOWN IN NEW EQUIPMENT PLAN, ELEVATIONS, AND DETAILS. <br />a. PROVIDE ALL LABOR AND MATERIALS FOR FABRICATION AND <br />INSTALLATION OF NEW CASEWORK FOR NOTED SPACES. <br />C. NEW FLOORING TO BE INSTALLED UNDER NEW CASEWORK, NOT <br />FINISHED TO IT. <br />a. PROVIDE ALL LABOR AND MATERIALS FOR INSTALLATION OF <br />NEW FLOORING UNDER NEW CASEWORK BEYOND THAT <br />INCLUDED WITHIN BASE BID. <br />BASE BID AND ALTERNATE NOTES #02: <br />THE NOTES INCLUDED HEREIN ARE FOR PCU PHASE 2- SEE PLANS & <br />KEYNOTES. <br />BASE BID: <br />A. EXISTING TILE FLOOR & WALL FINISHES WITHIN NOTED PCU <br />PHASE 2 TOILET ROOMS TO REMAIN. TLT ACCESSORIES FOR <br />NOTED TLT RMS TO REMAIN. <br />a. PCU PATIENT TLT RMS, SEMI -PRIVATE PATIENT ROOM TLT <br />RM, AND PUBLIC TLTS 2001, 2002 ,& 2276A. <br />b. PROVIDE ALL LABOR AND MATERIALS TO PREPARE EXISTING <br />GYPSUM -FACED WALLS WITHIN ABOVE NOTED SPACES TO <br />RECEIVE NEW EPDXY PAINT (SEE FINISH SCHEDULE). <br />c. PROVIDE ALL LABOR AND MATERIALS TO APPLY NEW EPXOY <br />PAINT TO GYPSUM WALLS IN ABOVE LISTED SPACES. SEE <br />FINISH PLAN AND KEYNOTES LEGEND. <br />d. PROVIDE ALL LABOR AND MATERIALS TO PREPARE & INSTALL <br />NEW OFOI TLT ACCESSORIES (DISPENSERS) WITHIN NOTED <br />TLT ROOMS. SEE EQUIPMENT PLAN. <br />ALTERNATE #02: <br />A. EXISTING TILE FLOOR AND WALL FINISH AT NOTED PCU PHASE 2 <br />TOILET ROOMS SHALL BE DEMOLISHED AND REMOVED. <br />a. PCU PATIENT TLT RMS, SEMI -PRIVATE PATIENT ROOM TLT <br />RM, AND PUBLIC TLTS 2001, 2002 ,& 2276A <br />b. PROVIDE ALL LABOR AND MATERIALS TO REMOVE EXISTING <br />FLOOR AND WALL TILE IN ROOMS LISTED ABOVE AND PREP <br />FOR NEW FINISHES. <br />B. INSTALL NEW FLOOR AND WALL (TILE & PAINT) FINISHES IN PCU <br />PHASE 2 TOILET ROOMS. SEE FLOOR AND WALL FINISH PLANS <br />FOR FINISHES TO BE INSTALLED. <br />a. PROVIDE ALL LABOR AND MATERIALS TO INSTALL NEW WALL <br />TILE TO BE INSTALLED ON WET WALLS. SEE FINISH PLAN & <br />FINISH SCHEDULE. <br />b. PROVIDE ALL LABOR AND MATERIALS (EPDXY PAINT) TO <br />PAINT ON NON -WET WALLS IN THE SPACES LISTED ABOVE. <br />SEE FINISH PLAN & FINISH SCHEDULE. <br />c. PROVIDE ALL LABOR AND MATERIALS TO INSTALL NEW <br />FLOOR TILE. SEE FINISH PLAN & FINISH SCHEDULE. <br />d. PROVIDE ALL LABOR AND MATERIALS TO INSTALL NEW CFCI, <br />OFCI, & OFCRI TLT ACCESSORIES (GRAB BARS, MIRROR, <br />ETC.) IN NOTED TOILET ROOMS. SEE EQUIP PLAN <br />e. PROVIDE SEPARATE LINE ITEMS FOR FLOOR AND WALL TILE. <br />PLAN - LVL 2 - PCU - SEMI-PRIV. PAT RM - NEW WORK <br />1 HOUR FIRE <br />—-5—♦S—*-S_ 1 HOUR FIRE/ SMOKE BARRIER <br />2 HOUR FIRE <br />-��-S--♦5--��5-- 2 HOUR FIRE/ SMOKE BARRIER <br />—�T—♦T TEMPORARY 1 HOUR FIRE <br />S—S— SMOKE BARRIER <br />-5-----5---�-c- "GRAY" = EXISTING RATING <br />TO REMAIN <br />PARTITIONS: <br />EXISTING/REMAINING <br />NEW WORK <br />C = _ DEMOLISHED <br />GENERAL NOTES: <br />DEMOLITION <br />1. LIGHT LINES INDICATE EXISTING <br />CONSTRUCTION TO REMAIN. <br />2. REMOVE ALL EXISTING CONSTRUCTION <br />INDICATED BY BOLD DASHED LINES. <br />3. REFER TO APH-101 SHEET FOR ADDITIONAL <br />PHASING AND PLAN INFORMATION <br />GENERAL NOTES: <br />NEW WORK <br />1. ALL WALLS ARE TYPE U UNLESS OTHERWISE <br />NOTED. <br />2. ALL DIMENSIONS ARE TO FINISH FACE OF <br />WALLS. <br />3. REFER TO APH-101 SHEET FOR ADDITIONAL <br />PHASING AND PLAN INFORMATION <br />KEYED NOTES: NEW WORK <br />O <br />ROOM NOT IN SCOPE. NO DEMOLITION WORK OR <br />NEW CONSTRUCTION WITHIN THIS SPACE. <br />(�.J <br />PATCH & REPAIR EXISTING WALL ASSEMBLY <br />WHERE EXISTING OR TEMPORARY ELEMENTS <br />HAVE BEEN REMOVED AND/OR DEMOLISHED. <br />a <br />OBSERVATION WINDOW AT SUB NURSE STATION. <br />EXISTING WINDOW TO BE REMOVED AND <br />REPLACED W/ NEW OBSERVATION WINDOW. SEE <br />FINISH SCHEDULE FOR INFORMATION. <br />INFILL WALL OPENING TO CREATE CONTINUOUS <br />WALL SURFACE. INFILL WITH METAL STUD & <br />GYPSUM SYSTEM TO MATCH EXISTING WALL <br />ASSEMBLY. COORDINATE W/ OTHER PATIENT <br />ROOM WALL AND HEADWALL WORK. <br />SEE ENLARGED TYPICAL PLANS AND ELEVATIONS <br />FOR PCU PATIENT ROOM CASEWORK, CEILINGS, <br />AND OTHER NOTES & REQUIREMENTS. <br />Q <br />SEE ENLARGED TYPICAL PLANS AND ELEVATIONS <br />FOR SUB -NURSE STATION CASEWORK, CEILINGS, <br />AND OTHER NOTES & REQUIREMENTS. <br />70 <br />SEE ENLARGED TYPICAL PLANS FOR PCU PATIENT <br />ROOM TOILET FIXTURES, CEILINGS, AND OTHER <br />NOTES & REQUIREMENTS. <br />EXISTING DOOR TO RECEIVE NEW FINISH. SEE <br />DOOR SCHEDULES AND NOTES ON A-501. <br />PCU PHASE 2: SEE BASE BID AND ALTERNATE #01 <br />FOR CASEWORK SCOPE IN THIS ROOM/SPACE. <br />10 <br />PCU PHASE 2: SEE BASE BID AND ALTERNATE #02 <br />FOR FINISH AND FIXTURE SCOPE IN THIS TLT RM. <br />11 <br />PCU PHASE 2: SEE BASE BID AND ALTERNATE #03 <br />FOR RE -FINISH SCOPE RELATED TO THIS EXISTING <br />DOOR. <br />12 <br />PCU PHASE 2: SEE BASE BID AND ALTERNATE #04 <br />FOR FINISH SCOPE WITHIN THIS ROOM/SPACE. <br />THIS SHEET RE -ISSUED <br />IN ITS ENTIRETY <br />PROJECT <br />NORTH <br />E <br />chapuis design group <br />arc hitecture.pa <br />510 VONDERBURG DR. SUITE 216 <br />BRANDON, FL 33511 <br />Tel. 813-667-2340 <br />CGDPA - FL # AA-26003049 <br />PROJECT FOR <br />ADVENTHEALTH - <br />ZEPHYRHILLS <br />PCU REFRESH <br />7050 Gall Blvd. <br />Zephyrhills, FL 33541 <br />AdventHealth <br />AHCA CLIENT CODE / FILE NUMBER: WA <br />1 <br />1 NOV. 2, 2022 <br />Addendum 2 - Construction Coordination <br />MARK <br />DATE <br />DESCRIPTION <br />PROJECT NUMBER <br />042-22-236.01 <br />ORIGINAL ISSUE <br />AUGUST 26, 2022 - <br />PROJECT MANAGER <br />TEC <br />PROJECT DESIGNER <br />TEC <br />PROJECT ARCHITECT <br />THOMAS E. CHAPUIS - AR97109 <br />B LANDSCAPE ARCHITECT <br />WA <br />CIVIL ENGINEER <br />N/A <br />STRUCTURAL ENGINEER <br />N/A <br />MECHANICAL ENGINEER <br />TIMOTHY P. PENNOCK - PE54516 <br />ELECTRICAL ENGINEER <br />CHARLES T. ALEXANDER - PE76422 <br />INTERIOR DESIGNER <br />CDG <br />EQUIPMENT PLANNER <br />WA <br />DRAWN BY <br />SDL <br />PLANS - PCU WING - <br />DEMOLITION &NEW <br />A WORK <br />As indicated <br />Aml 01 <br />92i <br />0 <br />N <br />O <br />Al <br />1/8" = V-0" <br />1 /8" = V-0" <br />1 2 3 4 5 6 <br />Project Status <br />II <br />