<br />WALLS TO BE PREPPED
<br />PRIOR TO WALL INTERIOR WINDOW
<br />PROTECTION INSTALL. I
<br />SEE MANUFACTURER'S
<br />-- TOP CAP TO BE INSTALLED AT
<br />INSTALL GUIDE — SILL REVEAL TO FINISH EDGES OF COMPONENT COVER TO SHEET WALL PROTECTION TOP CAP
<br />CORNER GUARDS OVERLAP PORTION OF WALL -- CORNER GUARD CAP TO ALIGN
<br />PROTECTION WITH SHEET WALL PROTECTION
<br />WHERE SILL DEPTH IS LARGER TOP CAP
<br />TOP CAP I THAN 3/4", INSTALL SCHEDULED
<br />1 SHEET WALL PROTECTION AT -- SURFACE MOUNT CORNER
<br />SILL REVEAL TO HEIGHT OF IF COMPONENT COVER GUARD. TRIM HEIGHT AS NEEDED
<br />MITRE JOINT AT ALL TOP CAP SURROUNDING WALL INTERSECTS TOP CAP OF WALL USING MANUFACTURER'S
<br />AND END TRIM PROTECTION. INSTALL 3/4" WING PROTECTION, INSTALL TOP RECOMMENDED METHOD
<br />INTERSECTIONS, SEAL GAPS ADHESIVE APPLIED CORNER CAP 1/16" FROM EDGE OF
<br />E i WITH MANUFACTURER'S GUARDS TO FINISH EDGES. COVER. SEAL ENDS OF TOP E
<br />RECOMMENDED COLOR CAP W/ COLOR MATCHED — SHEET WALL PROTECTION, AS SCHED.
<br />MATCHED CAULK WHERE SILL DEPTH IS LESS CAULK BEFORE RE -INSTALLING
<br />THAN 3/4", FINISH EDGE OF COMPONENT COVER. Chapuis design group
<br />WALL PROTECTION WITH TOP CORNER GUARD BOTTOM CAP- architecture -pa
<br />END TRIM- ROTATED TOP CAP CAPS. MITRE EDGES WHERE
<br />TRIM. SIZE OF ALL TOP/END CAPS INTERSECT PROVIDE ALLOWANCE FOR WALL
<br />SHEET WALL PROTECTION. BASE. SEE MANUFACTURER'S 510 VONDERBURG DR. SUITE 216
<br />TRIM TO BE SAME SIZE, UNLESS AS SCHED
<br />-- WHERE WINDOW INTERSECTS INSTALL GUIDE BRANDON, FL 33511
<br />OTHERWISE SPECIFIED.
<br />WALL PROTECTION, INSTALL CUT SHEET WALL PROTECTION Tel. 813-667-2340
<br />3/4" WING ADHESIVE APPLIED CGDPA - FL # AA-26003049
<br />TOP CAP SHEET WALL PROTECTION, CORNER GUARDS AT SILL TO TO MATCH DRYWALL OPENING
<br />AS SCHED. OR ANY SURFACE MOUNTED WALL BASE, AS SCHED.
<br />FINISH EDGES. MITRE
<br />CORNERS WHERE CORNER BRACKETS FOR WALL MOUNTED
<br />ITEMS
<br />GUARDS MEET.
<br />END CAP WALL PROTECTION- SURFACE
<br />E2 WALL PROTECTION- END TRIM AND TOP CAP E3 WALL PROTECTION- WINDOW TRIM E4 WALL PROTECTION -WALL MOUNTED COMPONENT E5 MOUNT CORNER GUARD _
<br />SHEET WALL
<br />NTS NTS
<br />PROTECTION HANDRAIL, AS SCHED. WHEN
<br />INSIDE FULLY ASSEMBLED WITH
<br />CORNER RETURNS, HANDRAIL SHALL BE 2" HANDRAIL, AS SCHED. VERIFY HANDRAIL IS 2"
<br />CLEAR OF ALL DOOR FRAMES AND CLR OF DOOR FRAMES AND OTHER EDGES
<br />DIVIDER BAR, OTHER PROTRUSIONS. SEE
<br />WHERE MANUFACTURER'S INSTALL GUIDE.
<br />SPEC'D. IF -
<br />DIV. BAR NOT `
<br />SHOWN, USE WALL GUARD, AS SCHED.
<br />BUTT JOINT. HANDRAILS AND WALL GUARDS � WALL GUARD, AS SCHED. LENGTH OF
<br />SEE MANU. SHALL BE THE SAME LENGTH, HANDRAIL AND WALL GUARD TO MATCH
<br />INSTALL MEASURED WITHOUT RETURNS ` MEASURED WITHOUT ENDS
<br />GUIDE. AND END PIECES.
<br />SHEET WALL PROTECTION, AS PROJECT FOR
<br />SCHED. INSTALLED CENTER TO
<br />WALL BASE
<br />D — OUTSIDE CORNER, SEE DETAILS FOR CENTER BETWEEN HANDRAIL AND �- CORNER GUARD, AS SCHED. SHEET WALL PROTECTION, AS SCHED. D A D V E N T H EA LT H -
<br />SURFACE MOUNT OR TAPE ON PER ��~ WALL GUARD. MEASUREMENTS ,
<br />DRAWINGS \ VARY BASED ON PRODUCT TYPE
<br />AND MOUNTING HEIGHTS. SEE VINYL COVER Z E P H YR H I L LS
<br />PROJECT SPECIFIC ELEVATIONS. U ' SHEET WALL PROTECTION, AS SCHED. INSTALL
<br />exp
<br />N QX ¢ CTR TO CTR BETWEEN HANDRAIL AND WALL
<br />> , GUARD CONTINUOUS ALUMINUM RETAINER
<br />�j
<br />CORNER GUARD. AS SCHED.
<br />WALL PROTECTION- RIGID VINYL SELF -DRILLING SCREWS
<br />WALL BASE, AS SCHED. 2" — WALL BASE, AS SCHED. P C U REFRESH
<br />SHEET AND TRIM COMPONENTS WALL PROTECTION- TYP. CORRIDOR COMPONENTS \3 ELEVATION- TYP. CORRIDOR WALL PROTECTION COMPONENTS D4 SECTION- SURFACE MOUNT CORNER GUARD
<br />D 1 NTS D2 112' = V-0"
<br />7050 Gall Blvd.
<br />Zephyrhills, FL 33541
<br />J
<br />CRAIN METAL AdventHealth
<br />INSIDE CORNER, C
<br />SILVER- U.N.O
<br />FINISHED WALL
<br />— SPECIFIED COVE CAP
<br />CRAIN METAL AHCA CLIENT CODE /FILE NUMBER: N/A
<br />OUTSIDE CORNER,
<br />SILVER- U.N.O
<br />— —
<br />INTEGRAL COVE BASE AS —\— - --
<br />\
<br />SCHEDULED. SEE—__—
<br />\
<br />ELEVATIONS.
<br />C , DETAIL -COVE BASE CORNERS
<br />MARK DATE DESCRIPTION
<br />PROJECT NUMBER 042.22.236.01
<br />WATERPROOF MEMBRANE
<br />AS REQUIRED ORIGINAL ISSUE AUGUST 26, 2022 -
<br />CONCRETE PROJECT MANAGER TEC
<br />WONDERBOARD OR PROJECT DESIGNER TEC
<br />SIMILAR CBU
<br />PROJECT ARCHITECT THOMAS E. CHAPUIS - AR97109
<br />B LANDSCAPE ARCHITECT N/A
<br />CEILING AS SCHED -- SCHLUTER CIVIL ENGINEER N/A
<br />' WALL TILE TO CLG TRANSITION-SCHIENE- ° ° STRUCTURAL ENGINEER N/A
<br />TRANSITION, AS AT TILED OUTSIDE — -
<br />' SCHEDULED CORNERS; UNLESS MECHANICAL ENGINEER TIMOTHY P. PENNOCK - PE54516
<br />OTHERWISE SPECIFIED ° °
<br />ELECTRICAL ENGINEER CHARLES T. ALEXANDER - PE_ 76422
<br />-F -- WALL TILE W/ SOFT JOINT AT WALL TILE INTERIOR DESIGNER CDG
<br />GROUT, AS SCHED. INSIDE CORNER TO W/ GROUT,
<br />EQUIPMENT PLANNER N/A
<br />ABSORB AS SCHED. ° CEMENTITIOUS BACKER UNIT --
<br />i — SCHLUTER MOVEMENT; SEAL (CBU), CONCRETE DRAWN BY JU
<br />TRANSITION- AS REQUIRED WONDERBOARD OR SIMILAR
<br />SCHIENE, AT ALL
<br />TILED OUTSIDE SECTION -WALL TILE W/ EXPANSION JOINTS
<br />' CORNERS,
<br />INSTALLED TO B2 1 1/2" = 1' 0"
<br />HEIGHT OF TILE ° ORGANIC ADHESIVE
<br />INSTALLATION;
<br />UNLESS
<br />OTHERWISE
<br />SPEC'D
<br />FLOOR TILE W/ GROUT AS SCHED. h
<br />SOFT JOINT AT ALL a.
<br />CEILING AS SCHED
<br />4
<br />'- TILED INSIDE t
<br />i CORNERS TO SEALANT, BACKER ROD. COMPRESSIBLE FILLER \ - WALL TILE TO CLG CERAMIC TILE `
<br />s ABSORB ° TRANSITION, AS SCHEDULED DRY -SET OR LATEX-PORTLAND
<br />MOVEMENT; SEAL
<br />AS REQUIRED WALL TILE W/ GROUT, CEMENT MORTAR BOND COAT
<br />i
<br />' — SOFT JOINT AT ° AS SCHEDULED CONCRETE WONDERBOARD
<br />i PERIMITER: CONCRETE SUBFLOOR OR SIMILAR CBU
<br />UNLESS OTHER
<br />' TRANSITION °
<br />SPEC'D; SEAL AS WALL TILE W/ GROUT, AS SCHED
<br />s
<br />'• REQUIRED INTERIOR DETAILS
<br />FLOOR TILE W/
<br />i GROUT, AS SCHED.
<br />A 1/4" WIDE CONTROL JOINT, A
<br />SAW CUT INTO CONCRETE SOFT JOINT; UNLESS OTHER
<br />TRANSITION SPECIFIED, SEAL AS REG.
<br />SHRINKAGE CRACK FLOOR TILE W/ GROUT, AS SCHED
<br />i
<br />CONCRETE SUBFLOOR
<br />SCALE As indicated
<br />— LATEX-PORTLAND CEMENT MORTAR BOND COAT
<br />CONCRETE SUBFLOOR STEEL TROWEL
<br />AND FINE BROOM FINISH: FREE OF
<br />CURING COMPOUNDS AND SEALERS
<br />TILE -FLOOR- EXPANSION JOINT OVER TILE -WALL- MASTIC ON CBU OVER
<br />_ _ 1=401
<br />TILE- EXPANSION JOINT DIAGRAM Cn
<br />A\ CONCRETE CONTROL JOINT A3 ).STEEL STUDS A4 SECTION WALL TILE, FULL HEIGHT / A5 TILE FLOOR-THINSET ON CONCRETE