Laserfiche WebLink
Ef <br />0 <br />A Cn <br />z <br />_O <br />f-- <br />> <br />w <br />J <br />w <br />w <br />w <br />U) <br />1 2 3 4 5 6 <br />ALL FILLERS TO BE FLUSH WITH <br />CABINET BODY <br />BACKSPLASH TO ALIGN <br />WITH EDGE OF COUNTERTOP <br />1 1/2" LAMINATED EDGE <br />COUNTERTOP AS SCHED.; 1" <br />FINISHED END OVERHANG; 1" <br />FRONT OVERHANG MEAS. <br />FROM DOOR / DRAWER FRONT <br />CABINET DRAWER AND <br />DOOR EDGES TO ALIGN, <br />ACCOMODATE FOR <br />HINGE CLEARANCE <br />ALL GRAIN / PATTERN,TO RUN <br />AND MATCH VERTICALLY: SEE <br />AWI STANDARDS FOR <br />PREMIUM GRADE CASEWORK <br />CASEWORK-TYP. BASE CAB <br />ITERTOP AS <br />DULED <br />KING AS <br />TIRED, TYP. <br />OGEE CURVE <br />ORT BRACKET <br />"YP. WORK <br />ACE <br />z <br />0 <br />> <br />w <br />J <br />w <br />O <br />w <br />w <br />w <br />Cc <br />CASEWORK- DRAWER BASE <br />1 1/2" LAMINATED EDGE <br />COUNTERTOP AS <br />SCHEDULED; WITH 3/4" <br />SEALED PLYWOOD <br />SUBSTRATE <br />DRAWER W/ SUBFRONT; <br />SEE SPEC FOR HARDWARE <br />REQUIREMENTS PER <br />DRAWER TYPE <br />HIGH PRESSURE LAMINATE <br />INTERIOR AND SHELVING <br />FINISH: SEE FIN. SCHED. <br />ALL FILLERS TO BE FLUSH WITH <br />CABINET BODY <br />BACKSPLASH TO ALIGN <br />WITH EDGE OF COUNTERTOP <br />1 112" LAMINATED EDGE <br />COUNTERTOP AS SCHED.; 1" <br />FINISHED END OVERHANG; <br />1" FRONT OVERHANG FROM <br />DOOR/DRAWER FRONT <br />CABINET DRAWER AND <br />DOOR EDGES TO ALIGN, <br />ACCOMODATE FOR <br />HINGE CLEARANCE <br />ALL GRAIN / PATTERN <br />TO RUN AND MATCH <br />VERTICALLY; SEE AWI <br />STANDARDSFOR <br />PREMIUM CASEWORK <br />z <br />O_ <br />H <br />a <br />> <br />w <br />J <br />w <br />O <br />w <br />w <br />w <br />w <br />NG FIXTURES AS SCHED. <br />BACKSPLASH TO <br />ALIGN W/ EDGE OF <br />COUNTERTOP; UNLESS <br />NOTED OTHERWISE <br />1 1/2" LAMINATED EDGE <br />COUNTERTOP AS <br />SCHED.; 1" OVERHANG <br />FROM FINISHED END <br />AND DOOR/DRAWER <br />FRONT <br />FINISH PANEL <br />ATTACHED W/ <br />STAINLESS STEEL <br />TAMPER RESISTANT <br />WASHERS AND <br />SCREWS <br />ALL GRAIN / PATTERN <br />TO RUN AND MATCH <br />VERTICALLY; SEE AWI <br />STANDARDS FOR <br />PREMIUM GRADE <br />CASEWORK <br />CASEWORK- SINK BASE W/ REMOVABLE PANEL <br />1 1/2" LAMINATED <br />COUNTERTOP AS <br />SCHEDULED; WITH 3/4" <br />SEALED PLYWOOD <br />SUBSTRATE <br />DRAWERS W/ SUBFRONT; <br />ELEVATION DENOTES TYPE <br />(I.E. "FILE"); SEE SPEC FOR <br />HARDWARE <br />REQUIREMENTS PER <br />DRAWER TYPE <br />3/4" BACK WITH <br />NAILERS; SEE SPEC <br />z <br />0 <br />> <br />w <br />J <br />w <br />0 <br />Ir <br />w <br />w <br />w <br />GYP. ASSEMBLY SOFFIT; <br />UNLESS OTHERWISE <br />SPECIFIED; SEE ELEVATIONS <br />1" CEILING SCRIBE <br />FINISH TO MATCH CASEWORK <br />ALL CABINET DOORS TO BE <br />INSTALLED WITH GRADE 1 <br />WRAPAROUND 5 KNUCKLE <br />HINGES; UNLESS OTHERWISE <br />NOTED <br />WHERE LIGHT VALANCE NOT <br />INSTALLED. WALL CABINET <br />DOORS ARE TO ALIGN WITH <br />BOTTOM EDGE OF CABINET BODY <br />ALL FILLERS TO BE FLUSH WITH <br />CABINET BODY <br />CASEWORK-TYP. WALL CAB <br />4" BACKSPLASH SAME AS <br />SCHEDULED COUNTERTOP; <br />UNLESS OTHERWISE SPECIFIED <br />1 1/2" LAMINATED <br />COUNTERTOP AS <br />SCHEDULED; W/ 3/4" SEALED <br />PLYWOOD SUBSTRATE <br />3/4" BACK WITH NAILERS; FIELD <br />VERIFY-ACCOMODATE FOR <br />PLUMBING AS NEEDED <br />REMOVABLE PANEL; FINISH <br />TO MATCH ADJACENT <br />CASEWORK; ATTACH W/ <br />STAINLESS STEEL TAMPER <br />RESISTANT WASHERS AND <br />SCREWS <br />HIGH PRESSURE LAMINATE CAB <br />INTERIOR NOT INTENDED FOR <br />STORAGE <br />U) <br />z <br />0 <br />t= <br />Q <br />w <br />w <br />0 <br />F- <br />Cr <br />w <br />w <br />w <br />rr <br />z <br />0 <br />> <br />w <br />J <br />w <br />O <br />w <br />w <br />w <br />GYP. ASSEMBLY <br />SOFFIT; UNLESS <br />OTHERWISE SPECIFIED; <br />SEE ELEVATIONS <br />1" CEILING SCRIBE: FINISH <br />TO MATCH CASEWORK <br />3/4" BACK WITH NAILERS <br />HIGH PRESSURE <br />LAMINATE INTERIOR AND <br />SHELVING FINISH: <br />SEE FIN. SCHED. <br />U) <br />z <br />0 <br />F=- <br />> <br />w <br />J <br />w <br />0 <br />w <br />w <br />w <br />CC <br />3YP. ASSEMBLY <br />SOFFIT; UNLESS <br />DTHERWISE <br />SPEC'D: SEE <br />ELEVATIONS <br />1" CEILING SCRIBE: <br />FINISH TO MATCH <br />;,ASEWORK <br />3/4" BACK W/ <br />HAILERS: SEE SPEC <br />HIGH PRESSURE <br />LAMINATE <br />INTERIOR AND <br />SHELVING <br />FINISH; SEE FIN. <br />SCHED. <br />E <br />7 <br />A <br />chapuis design group <br />architecture.pa <br />510 VONDERBURG DR. SUITE 216 <br />BRANDON, FL 33511 <br />Tel. 813-667-2340 <br />CGDPA - FL # AA-26003049 <br />exF <br />PROJECT FOR <br />ADVENTHEALTH - <br />ZEPHYRHILLS <br />PCU REFRESH <br />7050 Gall Blvd. <br />Zephyrhills, FL 33541 <br />AdventHealth <br />AHCA CLIENT CODE / FILE NUMBER: N/A <br />MARK DATE DESCRIPTION <br />PROJECT NUMBER <br />042.22.236.01 <br />ORIGINAL ISSUE <br />AUGUST 26, 2022. <br />PROJECT MANAGER <br />TEC <br />PROJECT DESIGNER <br />TEC <br />PROJECT ARCHITECT <br />THOMAS E. CHAPUIS - AR97109 <br />LANDSCAPE ARCHITECT <br />N/A <br />CIVIL ENGINEER <br />N/A <br />STRUCTURAL ENGINEER <br />N/A <br />MECHANICAL ENGINEER <br />TIMOTHY P. PENNOCK - PE54516 <br />ELECTRICAL ENGINEER <br />CHARLES T. ALEXANDER PE76422 <br />INTERIOR DESIGNER <br />CDG <br />EQUIPMENT PLANNER <br />N/A <br />DRAWN BY <br />JU <br />yC� <br />INTERIOR DETAILS - <br />CASEWORK <br />SCALE 1" = 1'-0" <br />1=402 <br />SECTION -OGEE CURVE BRACKET <br />SECTION-TYP. BASE CAB. <br />SECTION- DRAWER BASE <br />1 " = V-0" <br />SECTION- SINK BASE W/ REMOVABLE PANEL <br />1 " = V-0" <br />SECTION-TYP. WALL CAB. <br />1" = V-0" <br />SECTION- TALL CAB. W/ FULL HT DOOR <br />1" = V-0" <br />1�� 1 = l -U � I _ I -U \� 6 Project Status <br />1 2 3 4 5 <br />