Laserfiche WebLink
1 1_ t <br />i 1 <br />11 - II I ! <br />E <br />IC <br />A <br />1 <br />2 3 <br />4 5 6 <br />MEDICAL GAS OUTLETS <br />OUTLET QUANTITY <br />UNIT NUMBER TYPE OUTLET NOTES <br />MEDICAL ,MEDICAL NITROUS CARBON VACUUM ARRANGEMENT <br />OXYGEN NITROGEN ! WAGD <br />VACUUM AIR OXIDE DIOXIDE j SLIDE <br />i <br />MG 1 WALL OUTLET 2 2 Z - - - - i ' <br />O V A <br />GENERAL NOTES: <br />A. FACILITY CURRENTLY USES PURITAN-BENNETT OHMEDA STYLE OUTLETS. CONTRACTOR TO CONFIRM WITH FACILITY THAT THIS OUTLET STYLE <br />IS TO BE INSTALLED IN THE NEW SPACES PRIOR TO PURCHASING OUTLES. <br />B, VACUUM SLIDES TO BE HUNG ON UTILITY RAIL. <br />C. REFER TO ARCHITECTURAL DRAWINGS FOR OUTLET MOUNTING HEIGHTS AND LOCATIONS. <br />FIXTURE CONNECTIONS <br />FIXTURE <br />WASTE VENT <br />TRAP <br />COLD <br />HOT <br />NOTES <br />WATER CLOSET (FLUSH VALVE) <br />4" 2" INTEGRAL <br />1-1/4" <br />LAVATORY <br />�_ 2" <br />1 112" 1-1/4" <br />1/2' <br />1/2" <br />- <br />SINK <br />SHOWER - <br />2" <br />2" <br />1-1/2" 1-1/2" <br />1-112" -- 2" <br />1/2" 1/2" - <br />1/2" 112" - <br />GENERAL NOTES: <br />A. ALL SIZES INDICATED ARE GENERAL MINIMUM ACCEPTABLE PIPE SIZES TO EACH FIXTURE. <br />ACTUAL CONNECTION SIZES TO EACH FIXTURE MAY REQUIRE A TRANSITION. SEE FLOOR <br />PLANS AND RISERS FOR ADDITIONAL SIZES. <br />MARK <br />MAXIMUM FIXTURE UNITS - <br />MAXIMUM PRESSURE RATING <br />WATER HAMMER ARRESTORS <br />AA A B C D E F <br />I <br />3 11 32 60 113 154 330 <br />350 PSI <br />MANUFACTURER SIOUX CHIEF <br />MODEL NUMBER _ -_ 660 SERIES'. 650 SERIES <br />GENERAL NOTES: <br />A. THE BASIS OF DESIGN MANUFACTURER DOES NOT REQUIRE AN ACCESS PANEL FOR THE DEVICE. <br />MANUFACTURERS THAT REQUIRE ACCESS PANELS ARE NOT ACCEPTABLE. ACCESS PANELS ARE ONLY <br />TO BE PROVIDED FOR HAMMER ARRESTORS WHEN REQUIRED BY THAT JURISDICTION. <br />B. ALL WATER HAMMER ARRESTORS SHALL MEET ASSE 1010-2004 STANDARDS. <br />C. WATER HAMMER ARRESTORS ARE NOTED ON THE PLANS AND RISERS WITH THE ABBREVIATION 'WHA-X'. <br />14 <br />chapuis design group <br />architecture.pa <br />510 VONDERBURG DR. SUITE 216 <br />BRANDON, FL 33511 <br />Tel. 813-667-2340 <br />CGDPA - FL # AA-26003049 <br />exp U.S. Services Inc. <br />t: +1.407.660.0088 f: +1.407.660.1655 <br />2601 Westhall Lane <br />Maitland, FL 32751 <br />USA <br />www.exp.com <br />fj� • <br />•`•�i <br />Project* #22016657 <br />exp. <br />Cart of Auth: 29701 <br />PROJECT FOR <br />D ADVENTHEALTH - <br />ZEPHYRHILLS <br />A2 0PCU REFRESH3 <br />PROJECT <br />NORTH <br />B <br />A <br />7050 Gall Blvd. <br />Zephyrhills, FL 33541 <br />AHCA CLIENT CODE / FILE NUMBER: N/A <br />r <br />I <br />I <br />= <br />� <br />2 , 2022-11-02 <br />ADDENDUM 2 - CONSTRUCTION COORD. <br />1 2022-09-08 <br />'ADDENDUM #1 <br />MARK DATE <br />DESCRIPTION <br />PROJECT NUMBER <br />23/100046 <br />ORIGINAL ISSUE <br />AUGUST 26, 2022 - <br />PROJECT MANAGER <br />TEC <br />PROJECT DESIGNER <br />TEC <br />PROJECT ARCHITECT <br />THOMAS E. CHAPUIS - AR97109 <br />LANDSCAPE ARCHITECT <br />N/A <br />N/A <br />NIA <br />CIVIL ENGINEER <br />STRUCTURAL ENGINEER <br />MECHANICAL ENGINEER <br />TIMOTHY P. PENNOCK - PE54516 <br />ELECTRICAL ENGINEER <br />CHARLES T. ALEXANDER - PE76422 <br />INTERIOR DESIGNER <br />CDG <br />N/A <br />EQUIPMENT PLANNER <br />DRAWN BY j TRF <br />C) <br />No. 54516 <br />v <br />-A STATE OF j <br />:.�''.. '�� 12 <br />Fss t OR10�, *-0` <br />�ONIA 11 � <br />PLUMBING <br />SCHEDULES <br />SCALE': <br />P=601 <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />Project Status <br />