3 <br />If If1 III I qP 1141 It w I I I <br />1 <br />GENERAL NOTES: <br />1 NOT ALL SYMBOLS ON ELECTRICAL SYMBOLS <br />SHEET ARE USED. <br />2 ALL MOUNTING HEIGHTS ARE TO THE CENTERLINE <br />OF THE DEVICE BACKBOX UNLESS NOTED <br />OTHERWISE. <br />3 ALL ELECTRICAL SYSTEMS INSTALLATIONS SHALL <br />COMPLY WITH NFPA 70 (NATIONAL ELECTRICAL <br />CODE) AS WELL AS ALL APPLICABLE STATE AND <br />LOCAL CODES. IN ADDITION, FIRE ALARM SYSTEM <br />INSTALLATIONS SHALL COMPLY WITH NFPA 72 <br />(NATIONAL FIRE ALARM CODE). <br />4 DIVISION 26 CONTRACTOR IS RESPONSIBLE FOR <br />MAKING EVERY ATTEMPT TO CONCEAL RACEWAY <br />E SYSTEMS WITHIN WALLS OR ABOVE CEILINGS. <br />WHERE RACEWAY SYSTEMS MUST BE INSTALLED <br />WITHIN FRONT OF HOUSE EXPOSED AREAS, <br />CONTRACTOR SHALL INSTALL SYSTEM <br />COMPONENT PER CODE WITH CAREFUL <br />CONSIDERATION FOR THEMING AND EXTREME <br />SENSITIVITY FOR VISIBILITY OF SYSTEM <br />COMPONENTS. CONDUIT SHALL BE INSTALLED <br />PARALLEL OR PERPENDICULAR TO STRUCTURE <br />AS BEST FITS ROUTING REQUIREMENTS AND <br />SHALL BE INSTALLED IN A NEAT AND <br />PROFESSIONAL MANNER. REFER TO ARCHITECTS <br />PAINT SPECIFICATION SECTION AND <br />ARCHITECTURAL FINISH SCHEDULES TO <br />DETERMINE PAINT COLOR OF ALL EXPOSED <br />FRONT OF HOUSE RACEWAY SYSTEMS. <br />5 DIVISION 26 CONTRACTOR SHALL COORDINATE <br />ALL WORK WITH OTHER TRADES PRIOR TO AND <br />DURING INSTALLATION. <br />6 DIVISION 26 CONTRACTOR SHALL ENSURE THAT <br />ALL CONDUIT ROUTED THROUGH OR NEAR <br />CASEWORK SHALL NOT INTERFERE IN ANY WAY <br />WITH THE INTENDED USE OF OR SERVICING OF <br />EQUIPMENT OR COUNTERS. <br />7 DIVISION 26 CONTRACTOR SHALL NOT CUT, DRILL, <br />OR IN ANY OTHER MANNER ALTER ANY <br />STRUCTURAL MEMBER WITHOUT PRIOR WRITTEN <br />APPROVAL FROM THE STRUCTURAL ENGINEER. <br />8 DIVISION 26 CONTRACTOR SHALL, AFTER <br />EXAMINATION OF ALL PLANS AND <br />SPECIFICATIONS, INCLUDE ALL COSTS <br />NECESSARY FOR ALTERATION OF, MODIFICATION <br />OF, OR ADDITIONS TO THE ELECTRICAL SYSTEMS <br />NECESSARY FOR A COMPLETE AND APPROVED <br />INSTALLATION IN ALL ASPECTS. IT IS THE INTENT <br />THAT ALL COSTS REQUIRED BE INCLUDED IN THE <br />BID OF THIS TRADE. DIVISION 26 CONTRACTOR <br />D SHALL BASE THEIR PROPOSAL AND BID UPON THE <br />EQUIPMENT AS SCHEDULED OR SPECIFIED, USING <br />THE MANUFACTURERS AND MODEL NUMBERS AS <br />CALLED FOR IN THE SPECIFICATIONS AND <br />SCHEDULED ON THE DRAWINGS. IF MORE THAN <br />ONE MANUFACTURER OF EQUIPMENT IS <br />SPECIFIED, ANY ONE OF THE MANUFACTURERS <br />OF EQUIPMENT MAY BE USED IN THIS <br />CONTRACTOR'S PROPOSAL. <br />9 DIVISION 26 CONTRACTOR TO NOTIFY ELECTRICAL <br />ENGINEER, IN WRITING, OF ANY DISCREPANCIES <br />FOUND BETWEEN THE ELECTRICAL PLANS AND <br />OTHER ENGINEERING PLANS, ARCHITECTURAL <br />PLANS, OR EXISTING FIELD CONDITIONS PRIOR TO <br />FINAL BID PRICE OR PERMITTING. <br />10 IN CASE OF DISPUTE OR DOUBT AS TO INTENT OF <br />DRAWINGS OR SPECIFICATIONS, DIVISION 26 <br />CONTRACTOR SHALL CONTACT ELECTRICAL <br />ENGINEER AND OBTAIN WRITTEN CLARIFICATION <br />PRIOR TO PROCEEDING WITH AND BID OR <br />CONSTRUCTION SCOPE INVOLVED. <br />11 DIVISION 26 CONTRACTOR IS RESPONSIBLE FOR <br />ORDERING ALL MATERIALS IN SUFFICIENT TIME TC <br />AVOID DELAYING THE COMPLETION OF THE <br />PROJECT. DELAY IN DELIVERIES SHALL NOT BE <br />CONSIDERED A JUSTIFIABLE REASON FOR <br />SUBMISSION OF SUBSTITUTE MATERIALS. <br />12 ALL ELECTRICAL DEVICES AND COVER PLATES <br />SHALL BE PROVIDED PER THE COLOR SELECTED <br />BY THE ARCHITECT/INTERIOR DESIGNER. THE GC <br />SHALL BE RESPONSIBLE FOR ENSURING THAT <br />THE TELECOMMUNICATION DEVICE COVER <br />PLATES MATCH THE ELECTRICAL COVER PLATES <br />WITHIN THE SAME AREA. <br />13 DIVISION 26 CONTRACTOR SHALL ASSIST <br />LIGHTING DESIGNER/ARCHITECT/INTERIOR <br />DESIGNER WITH THE PROCESS OF AIMING AND <br />C FOCUSING ALL LUMINAIRES. THIS PROCESS MAY <br />INCLUDE WORKING OFF OF LIFTS AND WORKING <br />DURING NIGHTTIME HOURS. <br />14 FRONT -OF -HOUSE EMERGENCY LIGHTING MAY <br />NOT BE SHADED TO DESIGNATE EMERGENCY <br />LUMINAIRES. REFER TO CIRCUITING LEGEND FOR <br />INFORMATION REGARDING FRONT -OF -HOUSE <br />LUMINAIRE CIRCUITING FOR LUMINAIRES ON <br />EMERGENCY POWER. <br />15 CONTRACTOR SHALL BE RESPONSIBLE FOR <br />FIRESTOPPING ALL PENETRATIONS THROUGH <br />FIRE -RESISTANCE -RATED WALLL& HORIZONTAL <br />ASSEMBLIESLAND WEATHERPROOFING ALL <br />PENETRATIONS THROUGH EXTERIOR WALLS OR <br />ROOFS.LFIRESTOP SYSTEMS SHALL BE APPROVED <br />AND UL-LISTED, MEETING THE F RATING & T <br />RATING REQUIREMENTS IN CHAPTER 7 OF THE <br />BUILDING CODE. REFER TO ARCHITECTURAL <br />PLANS AND SPECIFICATIONS FOR APPLICABLE <br />FIRESTOP SYSTEMS. <br />A <br />a <br />N <br />CV <br />N <br />O <br />N <br />I <br />ABBREVIATIONS <br />A <br />I AMPERES <br />HP <br />HORSEPOWER <br />AAC <br />ABOVE ACCESSIBLE CEILING <br />HZ <br />HERTZ <br />AC <br />ALTERNATING CURRENT <br />IG <br />ISOLATED GROUND <br />ADA <br />AMERICANS WITH DISABILITIES ACT <br />JB <br />JUNCTION BOX <br />AF <br />AMPERE FRAME <br />KCMIL <br />THOUSAND CIRCULAR MILS <br />AFCI <br />ARC FAULT CIRCUIT INTERRUPTOR <br />KVA j <br />KILOVOLT -AMPERES <br />AFF <br />ABOVE FINISHED FLOOR <br />KVAR <br />KILOVOLT -AMPERES, REACTIVE <br />AFG <br />ABOVE FINISHED GRADE <br />KW <br />KILOWATTS <br />AFU <br />AMPERE FUSE <br />LTG <br />LIGHTING <br />AIC <br />AMPERES INTERRUPTING CAPACITY, <br />MAX <br />MAXIMUM <br />SYMMETRICAL <br />MCB j <br />MAIN CIRCUIT BREAKER <br />AL <br />ALUMINUM <br />MCC <br />MOTOR CONTROL CENTER <br />ARCH <br />ARCHITECT <br />AS <br />AMP SWITCH <br />MECH <br />MECHANICAL <br />AT <br />AMP TRIP <br />MIN <br />MINIMUM <br />ATS <br />AUTOMATIC TRANSFER SWITCH <br />MLO <br />MAIN LUGS ONLY <br />AWG <br />AMERICAN WIRE GAUGE <br />MTS <br />MANUAL TRANSFER SWITCH <br />BFC <br />BELOW FINISHED CEILING ( <br />MVA <br />MEGAVOLT-AMPERES <br />BFG <br />BELOW FINISHED GRADE <br />N <br />NEUTRAL <br />BKBD <br />BACKBOARD <br />NA <br />NOT APPLICABLE <br />BOH <br />BACK OF HOUSE <br />NC <br />NORMALLY CLOSED <br />C <br />CONDUIT <br />NEC <br />NATIONAL ELECTRICAL CODE <br />CAT <br />CATALOG <br />NF <br />NON FUSED <br />CB <br />CIRCUIT BREAKER <br />NO <br />NORMALLY OPEN <br />CFCI <br />CONTRACTOR FURNISHED <br />CONTRACTOR INSTALLED <br />NTS <br />NOT TO SCALE <br />CKT <br />CIRCUIT <br />OC <br />ON CENTER <br />CLG <br />CEILING <br />OFCI <br />OWNER FURNISHED CONTRACTOR <br />CO <br />CONDUIT ONLY <br />INSTALLED <br />CONT <br />CONTINUATION <br />OF01 <br />OWNER FURNISHED OWNER INSTALLED <br />CU <br />COPPER <br />O,PH <br />PHASE <br />CT <br />CURRENT TRANSFORMER <br />PC <br />PHOTOCELL <br />DELTA <br />FIR <br />PASSIVE INFRARED <br />DIV <br />I DIVISION <br />POC <br />POINT OF CONNECTION <br />DWG <br />DRAWING <br />POS <br />POINT OF SALE <br />EA <br />EACH <br />PLBG <br />PLUMBING <br />EC <br />EMPTY CONDUIT <br />PT <br />POTENTIAL TRANSFORMER <br />ELEC <br />ELECTRICAL <br />PVC <br />POLYVINYL CHLORIDE <br />EM <br />EMERGENCY <br />PWR <br />POWER <br />EMT <br />ELECTRICAL METALLIC TUBING <br />OTY <br />QUANTITY <br />EO <br />ELECTRICALLY OPERATED <br />REC <br />RECESSED <br />EP <br />EXPLOSION PROOF <br />RECPT <br />RECEPTACLE <br />EPO <br />EMERGENCY POWER OFF <br />REF <br />REFRIGERATOR <br />EQUIP <br />EQUIPMENT <br />RGS <br />RIGID GALVANIZED STEEL <br />ERMS <br />ENERGY -REDUCING MAINTENANCE SWITCH <br />SPD <br />SURGE PROTECTIVE DEVICE <br />EWC <br />ELECTRIC WATER COOLER <br />ST <br />SHUNT TRIP <br />EXIST <br />EXISTING <br />SURF <br />SURFACE <br />EXT <br />EXTERIOR <br />SWBD <br />SWITCHBOARD <br />FA <br />FIRE ALARM <br />SWGR <br />SWITCHGEAR <br />FACP <br />FIRE ALARM CONTROL PANEL <br />TBD <br />TO BE DETERMINED <br />FAA <br />FIRE ALARM ANNUNCIATOR <br />TYP <br />TYPICAL <br />FOH <br />FRONT OF HOUSE <br />UG <br />UNDERGROUND <br />FT <br />FEET OR FOOT <br />LINO <br />UNLESS NOTED OTHERWISE <br />FU <br />FUSE <br />V <br />VOLTS <br />G <br />GROUND <br />VFD <br />VARIABLE FREQUENCY DRIVE <br />GEN <br />GENERATOR <br />W <br />WATTS <br />GFCI <br />GROUND FAULT CIRCUIT INTERRUPTER <br />WP <br />WEATHER PROOF <br />GFI <br />GROUND FAULT INTERRUPTER <br />XFMR <br />TRANSFORMER <br />GFP <br />GROUND FAULT PROTECTION j <br />Y <br />WYE <br />HPRS <br />i HORSEPOWER RATED SWITCH <br />HOA <br />HAND OFF AUTOMATIC <br />DEVICE MOUNTING HEIGHT DIAGRAM <br />NOTE MOUNTING HEIGHTS FOR DEVICES UNLESS NOTED OTHERWISE <br />46" MAX 4" 44" MAX 4" - <br />BACKSPLASH� <br />-J <br />VARIES <br />SEE 48" <br />�I <br />ID/ARCH <br />18" LJ 18" J <br />FLOOR <br />RECEPTACLE COMMUNICATION ABOVE RECEPTACLE TV <br />OUTLET WALL SWITCH, LOW VOLTAGE <br />& TV COUNTER ABOVE WALL (RECESSED) <br />SWITCH, WALL SWITCH <br />RECEPTACLE OR SINK <br />OCCUPANCY SENSOR, TIMER <br />COMMUNICATIONS <br />& WALLBOX DIMMER <br />FILING 12" MAX TO TOP <br />J , <br />I <br />XX <br />NOTED NOTED <br />J II <br />ON ON <br />PLANS PLANS <br />60„ <br />48" 48" 48" <br />FLOOR <br />WALL PHONE CARD READER, SHUNT TRIP TIMECLOCK <br />WALL MOUNTED WALL <br />KEYPAD, RTE, PUSHBUTTON (LIGHTING <br />CAMERA, & PTZ MOUNTED <br />PUSHPLATE,DOORBELL, (EMERGENCY CONTROL) <br />CAMERA SPEAKER <br />& BIOMETRIC READER POWER OFF) <br />- - <br />CL <br />EXIT <br />h 6" <br />I90" (AUDIBLE <br />8" BELOW CEILING, DEVICES SHALL <br />DOOR <br />MAXIMUM 12'-0" AFF. NOT BE CLOSER <br />E THAN 6" TO TOP <br />o <br />OF DEVICE TO <br />4" <br />CEILING IN LOW <br />48" CEILING AREAS) <br />r- <br />EXIT EXIT <br />FLOOR <br />10"-12" 10"-12" <br />< <br />- - <br />WALL WALL MOUNTED FIRE ALARM FIRE ALARM WALL <br />MOUNTED EMERGENCY PULL VISUAL, AUDIO & <br />OCCUPANCY LIGHT STATION AUDIONISUAL <br />SENSOR NOTIFICATION <br />FIRE ALARM SYSTEM <br />XXcd <br />FIRE ALARM VISUAL DEVICE, WALL <br />XXcd <br />FIRE ALARM VISUAL DEVICE, CEILING <br />MOUNTED. 'XXcd' INDICATES STROBE <br />0 <br />MOUNTED. 'XXcd' INDICATES STROBE <br />CANDELA RATING <br />CANDELA RATING <br />75cd UNLESS NOTED OTHERWISE <br />! 75cd UNLESS NOTED OTHERWISE <br />FIRE ALARM AUDIO DEVICE, WALL <br />FIRE ALARM AUDIO DEVICE, CEILING <br />MOUNTED <br />MOUNTED <br />XXcd <br />FIRE ALARM AUDIOVISUAL DEVICE, <br />XXcd <br />FIRE ALARM AUDIOVISUAL DEVICE, <br />7< X <br />WALL MOUNTED. 'XXcd' INDICATES <br />X <br />CEILING MOUNTED. 'XXcd' INDICATES <br />STROBE CANDELA RATING <br />STROBE CANDELA RATING. <br />75cd UNLESS NOTED OTHERWISE <br />75cd UNLESS -NOTED -OTHERWISE <br />NOTE: FOR <br />ABOVE AUDIO AND AUDIOVISUAL DEVICES, SUBSCRIPT'X' <br />INDICATES: <br />O <br />CARBON MONOXIDE DETECTOR, CEILING <br />MOUNTED <br />F1 <br />FIRE ALARM PULL STATION <br />HEAT DETECTOR, CEILING MOUNTED <br />2: <br />SMOKE DETECTOR, WALL MOUNTED <br />FS - FIRE SERVICE ELEVATOR <br />- <br />CO - WITH CARBON MONOXIDE <br />LOBBY TEMPERATURE MONITORING <br />E - ELEVATOR RECALL <br />SB - INTEGRAL SOUNDER BASE <br />J <br />SMOKE DETECTOR, CEILING MOUNTED <br />SS - NON SYSTEM SINGLE STATION TYPE <br />CO - WITH CARBON MONOXIDE <br />E - ELEVATOR RECALL <br />z X <br />BEAM SMOKE DETECTOR, SUBSCRIPT <br />SB - INTEGRAL SOUNDER BASE <br />'X' INDICATES: <br />SS - NON SYSTEM SINGLE STATION TYPE <br />BT - BEAM TRANSMITTER <br />BR - BEAM RECEIVER <br />SMOKE DETECTOR, DUCT MOUNTED. <br />X <br />SUBSCRIPT'X' INDICATES UNIT SERVED <br />SMOKE DAMPER <br />FIRE/SMOKE DAMPER <br />_ <br />FS' <br />FLOW SWITCH <br />TSi <br />TAMPER SWITCH <br />P <br />! PRESSURE ALARM <br />RTI <br />REMOTE TEST STATION <br />CONTROL RELAY <br />4 F <br />FIREFIGHTERS TELEPHONE OUTLET <br />ELECTRO-MAGNETIC DOOR HOLDER <br />_ <br />E <br />KB' <br />KNOX BOX <br />ELECTRIC FIRE BELUGONG <br />FIRE ALARM PANEL <br />XXXX <br />XXXX INDICATES TYPE <br />FACP - FIRE ALARM CONTROL PANEL <br />FATC - FIRE ALARM TERMINAL CABINET <br />FAA - FIRE ALARM REMOTE <br />ANNUNCIATOR <br />ASD - ASPIRATING SMOKE DETECTION <br />CONTROL PANEL <br />VEP - VOICE EVACUATION PANEL <br />COMMUNICATIONS <br />SYSTEM <br />X <br />DATA OUTLET, WALL MOUNTED <br />< X <br />VOICE OUTLET, WALL MOUNTED <br />X <br />DATA OUTLET, FLOOR MOUNTED <br />U X <br />VOICE OUTLET, FLOOR MOUNTED <br />*X <br />DATA OUTLET, CEILING MOUNTED <br />X <br />VOICE OUTLET, CEILING MOUNTED <br />X <br />VOICE -DATA OUTLET, WALL MOUNTED <br />04 <br />AUDIOVISUAL OUTLET, WALL MOUNTED <br />4' <br />X <br />VOICE -DATA OUTLET, FLOOR MOUNTED <br />�i <br />AUDIOVISUAL OUTLET, FLOOR <br />MOUNTED <br />VOICE -DATA OUTLET, CEILING <br />4 <br />j AUDIONISUAL OUTLET, CEILING <br />X <br />MOUNTED <br />MOUNTED <br />- <br />NOTE: FOR ABOVE VOICE, DATA AND AUDIONISUAL DEVICES, SUBSCRIPT'X' INDICATES: <br />C - <br />ABOVE BACKSPLASH OF CABINET, OR COUNTERTOP PV - PHOTO VENDOR <br />F - <br />FURNITURE OR MILLWORK MOUNTED RP <br />- RIDE PHONE -MOUNT 48" A.F.F. <br />H <br />HORIZONTALLY MOUNTED W WALL PHONE -MOUNT 48" A.F.F. <br />POS- <br />DEDICATED FOR POINT OF SELL OUTLET WP WEATHER PROOF <br />SPEAKER WALL MOUNTED X <br />SPEAKER CEILING MOUNTED <br />:1 <br />CCTV CAMERA, WALL MOUNTED ! <br />CCTV CAMERA, CEILING MOUNTED <br />-4 <br />TV OUTLET - WALL MOUNTED i TV <br />TV OUTLET - CEILING MOUNTED <br />j PLYWOOD BACKBOARD <br />COMMUNICATIONS <br />SYSTEMS NOTES: <br />1. FOR WALL AND CEILING MOUNTED DEVICES PROVIDE 4-11/16" BY 2-1/8" DEEP BACKBOX WITH SINGLE GANG <br />REDUCTION RING AT EACH LOCATION, UNO. <br />2. PROVIDE A 1" CONDUIT FROM EACH JUNCTION BOX BACK TO CLOSEST LOW VOLTAGE CABLE PATHWAY <br />(CABLE <br />TRAY, J HOOKS) IF SHOWN ON DRAWINGS OR UP ABOVE ACCESIBLE <br />CEILING IF LOW VOLTAGE CABLE <br />PATHWAYS ARE NOT SHOWN OR SPECIFIED IN SPECIFICATIONS, UNO. <br />ELECTRONIC ACCESS CONTROL SYSTEM <br />DR PROXIMITY/CARD READER DC DOOR CONTACT <br />ELECTRIC STRIKE ES ''I ACP j ACCESS CONTROL PANEL <br />M MAGNETIC LOCK <br />ELECTRONIC ACCESS CONTROL SYSTEM NOTES: <br />1. PROVIDE A 4-11/16" SQUARE BY 2-1/8" DEEP BACK BOX WITH A SINGLE GANG REDUCTION RING AT EACH <br />LOCATION UNO. <br />2. PROVIDE A 3/4" CONDUIT ROUTED TO THE ACCESS CONTROL JUNCTION BOX LOCATED ABOVE THE DOOR <br />UNO. <br />3. DOOR RELEASE BUTTON SHALL BE SURFACE MOUNTED TO UNDERSIDE OF COUNTER/DESK. MOUNT THE <br />BACKBOX DIRECTLY BELOW THE COUNTER PROVIDE AND INSTALL SURFACE MOUNTED RACEWAY FROM <br />THE BACKBOX TO THE DOOR RELEASE BUTTON LOCATION UNO. <br />NURSE CALL SYSTEM <br />tXX <br />NURSE CALL STATION <br />- - <br />DEVICE NOTES: <br />1. NURSE CALL STATION. PROVIDE A 4-11/16" SQUARE BY 2-1/8" DEEP BACK BOX WITH A SINGLE GANG <br />REDUCTION RING <br />AND A 1" CONDUIT ROUTED BETWEEN THE BACK BOX AND THE NEAREST CABLE PATHWAY, UNO. <br />XX = DEVICE DESCRIPTION <br />CB = CODE BLUE <br />CBA = CODE BLUE WITH STAFF ASSIST BUTTON <br />CBM = CODE BLUE ANNUNCIATOR <br />SA = STAFF ASSIST <br />P = PATIENT STATION <br />E = EMERGENCY PULL STATION <br />ES = EMERGENCY PULL SHOWER STATION <br />M = MASTER STATION <br />T = TOILET STATION <br />2. NURSE CALL STATION. PROVIDE A 3-GANG BY 2-1/8" DEEP BACK BOX WITH A 1" CONDUIT ROUTED <br />BETWEEN THE BACK <br />BOX AND THE NEAREST CABLE PATHWAY, UNO. <br />XX = DEVICE DESCRIPTION <br />DS = DUTY STATION <br />P = PATIENT STATION <br />XX <br />NURSE CALL CORRIDOR LIGHT, <br />XX <br />NURSE CALL CORRIDOR LIGHT, <br />XCEILING-MOUNTED <br />WALL -MOUNTED <br />DEVICE NOTES: <br />1. PROVIDE A 4-11/16" SQUARE BY 2-1/8" DEEP BACK BOX WITH A SINGLE GANG REDUCTION RING AT EACH <br />LOCATION, UNO. <br />2. PROVIDE A 1" CONDUIT ROUTED BETWEEN THE BACK BOX AND THE NEAREST CABLE PATHWAY, LINO. <br />XX = DEVICE DESCRIPTION <br />C = CEILING <br />NCCP NURSE CALL CONTROL PANEL <br />❑R NURSE CALL RELAY <br />4 <br />LIGHTING <br />=� R10 UPPER CASE LETTERS INDICATES THE LUMINAIRE SERIES TYPE, <br />7a NUMBER INDICATES A DIFFERENT LUMINAIRE TYPE WITHIN THE SERIES <br />NL <br />NUMBER INDICATES CIRCUIT NUMBER, <br />LOWER CASE LETTER INDICATES SWITCH LEG <br />NIGHT LIGHT DESIGNATION INDICATES UNSWITCHED AND CONTINUOUSLY "ON" <br />LUMINAIRE SHADING LEGEND - TYPICAL FOR EACH LUMINAIRE TYPE <br />NORMAL BRANCH NEC 700 <br />NEC 517 <br />LIFE SAFETY <br />CRITICAL BRANCH <br />BRANCH AND/OR <br />BATTERY PACK <br />--� i <br />—- <br />TROFFER <br />ADJUSTABLE DOWNLIGHT <br />STRIP LIGHT <br />�-O <br />SCONCE <br />RECESSED STRIP LIGHT <br />PENDANT <br />_ <br />WALL MOUNTED STRIP LIGHT <br />BOLLARD <br />CIRCULAR APERTURE DOWNLIGHT <br />POLE MOUNTED LIGHT <br />❑ <br />SQUARE APERTURE DOWNLIGHT <br />EB• <br />SURFACE MOUNTED SPECIALTY LIGHT <br />O <br />I <br />WALL MOUNTED CHARACTER <br />WALL MOUNTED SPECIALTY LIGHT <br />BASE MOUNTED CHARACTER <br />{B+ <br />TRACK MOUNTED SPECIALTY LIGHT q <br />RECESSED PATH LIGHT <br />Q)+ <br />SURFACE MOUNTED ACCENT LIGHT <br />[] <br />SURFACE PATH LIGHT <br />�► <br />WALL MOUNTED ACCENT LIGHT <br />® <br />INGRADE UPLIGHT <br />�► <br />TRACK MOUNTED ACCENT LIGHT <br />®► <br />INGRADE DIRECTIONAL UPLIGHT <br />� <br />SURFACE <br />C MOUNTED CHARACTER <br />Ell <br />UNDERWATER LIGHT <br />O <br />PENDANT MOUNTED CHARACTER <br />►C11 <br />SURFACE UNDERWATER LIGHT <br />C:J <br />I THEATRICAL LEKO <br />ODD <br />FAN <br />C7 <br />THEATRICAL FOLLOW SPOT <br />TRACK <br />Q <br />THEATRICAL PAR <br />LINEAR LIGHT <br />C1 <br />THEATRICAL FRESNEL <br />--_� <br />LINEAR SLOT LIGHT <br />EMERGENCY LIGHT <br />MULTILAMP STRING LIGHT <br />EXIT <br />SIGNS <br />( � <br />CEILING MOUNTED SINGLE FACE EXIT <br />1141 <br />CEILING MOUNTED DOUBLE FACE EXIT <br />SIGN - ARROWS INDICATE DIRECTION <br />SIGN -ARROWS INDICATE DIRECTION <br />II <br />WALL MOUNTED SINGLE FACE EXIT SIGN <br />Kr <br />I WALL MOUNTED DOUBLE FACE EXIT <br />X + <br />ARROWS INDICATE DIRECTION <br />SIGN - ARROWS INDICATE DIRECTION <br />SUBSCRIPT'_' INDICATES LOW <br />LEVEL EXIT SIGN <br />KT <br />WALL END -MOUNTED SINGLE FACE EXIT <br />SIGN ARROWS INDICATE DIRECTION <br />SWITCHES <br />1 CONTROLS <br />X <br />WALL MOUNTED SWITCH <br />OCCUPANCY AND VACANCY SENSORS <br />ab <br />'ab' INDICATES INDIVIDUAL GANGED <br />SWITCHES AND ASSOCIATED SWITCH LEGS <br />CONTROLLED, SUBSCRIPT'X' INDICATES: <br />X OCCUPANCYNACANCY SENSOR, <br />2 DOUBLE POLE <br />ab <br />CEILING MOUNTED <br />3 - THREE WAY <br />OCCUPANCYNACANCY SENSOR, WALL <br />4 - FOUR WAY <br />� �, X <br />MOUNTED (REFER TO MOUNTING HEIGHT <br />D - WALL BOX DIMMER <br />ab <br />LEGEND) <br />EP EXPLOSION PROOF <br />X <br />OCCUPANCYNACANCY SENSOR, WALL <br />F- FAN SWITCH <br />ab <br />SWITCH TYPE <br />H - HORSEPOWER RATED <br />K - KEY OPERATED <br />NOTE: 'ab' INDICATES SWITCH LEGS <br />LV - LOW VOLTAGE TYPE <br />CONTROLLED, SUBSCRIPT'X' <br />P - PILOT LIGHT <br />INDICATES: <br />T - WALL BOX TIMER <br />VS - VACANCY SENSOR TYPE <br />W - WIRELESS <br />OS - OCCUPANCY SENSOR TYPE <br />WP - WEATHER PROOF <br />LV - LOW VOLTAGE SWITCH <br />LIGHTING CONTROL PANEL CONTROL <br />W - WIRELESS <br />JulSTATION <br />SUBSCRIPT'X' INDICATES <br />UNIQUE IDENTIFIER <br />X <br />CONTACTOR, SUBSCRIPT'X' INDICATES <br />n. <br />LIGHTING CONTROL WALL STATION, <br />UNIQUE IDENTIFIER <br />X <br />SUBSCRIPT'X' INDICATES UNIQUE <br />IPCI X <br />PHOTOCELL <br />IDENTIFIER <br />TCI, <br />TIME CLOCK, SUBSCRIPT'X' INDICATES <br />ALCR AUTOMATIC LOAD CONTROL RELAY <br />X <br />UNIQUE IDENTIFIER <br />(EMERGENCY LIGHTING) <br />BCELTSI, BRANCH CIRCUIT EMERGENCY LIGHTING <br />DSI X <br />DAYLIGHT SENSOR, CEILING MOUNTED <br />TRANSFER SWITCH (EMERGENCY LIGHTING) <br />IN -GRADE BOXES <br />I <br />M XX HANDHOLE WX XX - _ X <br />_ - - BOX NUMBER <br />M MANHOLE SIZE DESIGNATION/TYPE <br />- XX - -------BOX TYPE <br />P PULLBOX HH-HANDHOLE <br />__- MH-MANHOLE <br />PB-PULLBOX <br />DEVICE NOTES: UTILITY TYPE <br />REFER TO DETAILS FOR EXACT BOX TYPE, SIZE AND C-COMMUNICATION <br />SPECIFICATIONS. P-POWER <br />EXAMPLE: CMH-1-01 <br />POWER CONNECTIONS <br />JUNCTION BOX, WALL MOUNTED <br />� <br />JUNCTION BOX, CEILING MOUNTED <br />SPECIAL EQUIPMENT CONNECTION, <br />WALL MOUNTED. SUBSCRIPT'X' <br />SPECIAL EQUIPMENT CONNECTION, <br />{� <br />INDICATES UNIQUE IDENTIFIER, REFER <br />� <br />CEILING MOUNTED. SUBSCRIPT'X' <br />X <br />TO EQUIPMENT CONNECTION <br />X <br />INDICATES UNIQUE IDENTIFIER, REFER <br />SCHEDULE. <br />TO EQUIPMENT CONNECTION SCHEDULE. <br />DISCONNECT SWITCH, REFER TO <br />COMBINATION MOTOR STARTER <br />EQUIPMENT CONNECTION SCHEDULE <br />DISCONNECT, REFER TO EQUIPMENT <br />FOR DISCONNECT TYPE, UNO <br />CONNECTION SCHEDULE FOR <br />DISCONNECT TYPE, UNO <br />MOTOR, SUBSCRIPT W DENOTES <br />-B <br />VARIABLE FREQUENCY DRIVE <br />�CVX <br />MOTOR DESIGNATION, REFER TO <br />EQUIPMENT CONNECTION SCHEDULE <br />SHUNT TRIP PUSH BUTTON <br />4 <br />B BUILDING SHUNT TRIP <br />POWER POLE <br />OR - LIGHTING OVERRIDE <br />5 <br />RECEPTACLES <br />rl�j <br />DUPLEX RECEPTACLE, WALL MOUNTED <br />I <br />DOUBLE DUPLEX RECEPTACLE, WALL <br />I <br />MOUNTED <br />DUPLEX RECEPTACLE, ABOVE <br />DOUBLE DUPLEX RECEPTACLE, ABOVE <br />BACKSPLASH OF CABINET, <br />BACKSPLASH OF CABINET, <br />COUNTERTOP OR SINK <br />COUNTERTOP OR SINK <br />DUPLEX RECEPTACLE, FLUSH MTD IN <br />DOUBLE DUPLEX RECEPTACLE, FLUSH <br />CEILING <br />MOUNTED IN CEILING <br />HALF SWITCHED DUPLEX RECEPTACLE, <br />SIMPLEX RECEPTACLE, WALL MOUNTED <br />WALL MOUNTED <br />, <br />I <br />SPECIAL PURPOSE RECEPTACLE, WALL <br />SPECIAL PURPOSE RECEPTACLE, <br />MOUNTED. NEMA CONFIGURATION AS <br />CEILING MOUNTED NEMA <br />TYPE <br />I NOTED ON PLANS TYPE CONFIGURATION AS NOTED ON PLANS <br />OCCUPANCY CONTROLLED/SWITCHED <br />OCCUPANCY CONTROLLED/SWITCHED <br />DUPLEX RECEPTACLE, ABOVE <br />DUPLEX RECEPTACLE, WALL MOUNTED <br />BACKSPLASH OF CABINET, <br />OCCUPANCY CONTROLLED/ HALF <br />COUNTERTOP OR SINK <br />SWITCHED DOUBLE DUPLEX <br />OCCUPANCY CONTROLLED/ HALF <br />RECEPTACLE, WALL MOUNTED <br />SWITCHED DOUBLE DUPLEX <br />MA- <br />MULTI OUTLET ASSEMBLY, "X" <br />RECEPTACLE, ABOVE BACKSPLASH OF <br />X <br />INDICATES TYPE <br />CABINET, COUNTERTOP OR SINK <br />X RECEPTACLE TYPE <br />12— NUMBER INDICATES BRANCH CIRCUIT NUMBER <br />NOTE: <br />FOR ABOVE DEVICES, SUBSCRIPT'X' INDICATES: <br />CK - CLOCK HANGER <br />P PEDESTAL TYPE <br />EP EXPLOSION PROOF <br />R - RECESSED OUTLET <br />EQ EQUIPMENT MOUNTED <br />SS SURGE SUPPRESSION <br />EWC - ELECTRIC WATER COOLER <br />T TAMPER PROOF <br />F - FURNITURE OR MILLWORK MOUNTED <br />TV TELEVISION OUTLET <br />GFI - GROUND FAULT INTERRUPTER <br />WP - WEATHER PROOF <br />H HORIZONTALLY MOUNTED <br />U - USB TYPE <br />IG ISOLATED GROUND <br />RECEPTACLE BRANCH CIRCUIT SHADING <br />' SEE RECEPTACLE TYPES BELOW FOR CONFIGURATION <br />SHADING REPRESENTS RECEPTACLE ` <br />� <br />SHADING REPRESENTS RECEPTACLE <br />! <br />NEC 700 - LIFE SAFETY BRANCH <br />ON NEC 517 CRITICAL BRANCH <br />SHADING REPRESENTS RECEPTACLE <br />ON NEC 701/517 STANDBY/EQUIPMENT <br />SHADING REPRESENTS RECEPTACLE <br />BRANCH <br />ON UPS BRANCH <br />FLOOR <br />OUTLETS <br />j FLOOR BOX, SINGLE SERVICE TYPE <br />FLOOR BOX, SINGLE SERVICE TYPE <br />DUPLEX RECEPTACLE <br />DOUBLE DUPLEX RECEPTACLE <br />FLOOR BOX, MULTI -SERVICE TYPE <br />--, <br />FLOOR BOX, MULTI -SERVICE TYPE, <br />DOUBLE DUPLEX/COMMUNICATIONS <br />DUPLEX/COMMUNICATIONS OUTLET <br />OUTLET <br />00 <br />POKE THRU, SINGLE SERVICE TYPE <br />(J <br />FLOOR BOX, SINGLE -SERVICE TYPE <br />DUPLEX RECEPTACLE <br />JBOX (POWER) - UNO <br />I <br />VO POKE THRU, MULTI -SERVICE TYPE <br />�1 <br />FLOOR BOX, MULTI -SERVICE TYPE <br />JBOX <br />POWER/COMMUNICATIONS OUTLET <br />(POWER)/COMMUNICATIONS <br />POKE THRU, MULTI -SERVICE TYPE1 <br />POKE THRU, SINGLE SERVICE TYPE <br />DOUBLE DUPLEX RECEPTACLE <br />( JBOX (POWER)/COMMUNICATIONS <br />POKE THRU, SINGLE -SERVICE TYPE <br />POKE THRU, MULTI -SERVICE TYPE, <br />DOUBLE DUPLEX/COMMUNICATIONS <br />JBOX (POWER) - UNO <br />OUTLET <br />FLOOR BOX TYPE (REFER <br />TO SPECIFICATIONS FOR FLOOR BOX TYPES AND <br />X- CATALOG NUMBERS AND <br />QUANTITY AND SIZES OF CONDUITS TO EACH BOX,UNO) <br />12—NUMBER INDICATES BRANCH CIRCUIT NUMBER <br />FLOOR BOX, CONFIGURATION AS INDICATED, <br />FLUSH MOUNTED, UNLESS OTHERWISE NOTED. <br />NOTE: FOR ABOVE DEVICES, SUBSCRIPT'X INDICATES: <br />AF - MULTI -SERVICE TYPE - ACCESS FLOOR <br />"'C' SUBSCRIPT NEXT TO ANY <br />BR - MULTI -SERVICE TYPE - BALLROOM TYPE <br />FLOOR BOX INDICATES HALF OF <br />CC - MULTI -SERVICE TYPE - CONVENTION CENTER <br />TYPE RECEPTACLES IN BOX TO BE <br />F - FURNITURE FEED <br />AUTOMATICALLY CONTROLLED <br />M - MULTI -SERVICE TYPE <br />S# - SINGLE -SERVICE TYPE. # - # OF GANGS <br />WP - SINGLE -SERVICE WEATHERPROOF TYPE - (POWER OR DATA ONLY) <br />SINGLE LINE SYMBOLS <br />CKT BREAKER, '###' INDICATES <br />TRIP SETTING, W INDICATES UTILITY METER <br />i NUMBER OF POLES <br />• X <br />SS - SOLID STATE <br />GFP - GROUND FAULT PROTECTION <br />ERMS - ENERGY -REDUCING ^^ ^^ MINI POWER <br />MAINTENANCE SWITCH ZONE PANEL <br />EO - ELECTRICALLY OPERATED PANEL <br />NAME <br />ENCLOSED NON -FUSED <br />DISCONNECT SWITCH <br />I <br />/ ENCLOSED FUSED DISCONNECT PANEL <br />###/# d SWITCH'###' INDICATES TRIP NAME PANELBOARD <br />SETTING,'#' INDICATES NUMBER <br />OF POLES <br />ENCLOSED CIRCUIT BREAKER <br />###I# ) '###' INDICATES TRIP SETTING,'#' <br />INDICATES NUMBER OF POLES <br />I <br />FUSED SWITCH, ### INDICATES <br />###/# q TRIP SETTING,'#' INDICATES <br />�\ NUMBER OF POLES L <br />KIRK KEY E N <br />K -- INTERLOCK <br />DMM DIGITAL MULTI - <br />METER <br />L <br />BP <br />I <br />ST SHUNT TRIP IS <br />0i ATS <br />E N <br />SPD <br />SURGE SUPPRESSION <br />DEVICE <br />_ <br />GROUND <br />TRANSFORMER <br />SHIELD/ISOLATION TRANSFORMER <br />PAD MOUNTED <br />TRANSFORMER <br />I <br />I <br />GF ALARM ONLY <br />(D-- <br />GENERATOR <br />CONNECTION <br />PANEL WITH <br />MANUAL <br />TRANSFER <br />SWITCH <br />AUTOMATIC <br />TRANSFER <br />SWITCH <br />AUTOMATIC <br />TRANSFER <br />SWITCH WITH <br />BYPASS <br />ISOLATION <br />GENERATOR <br />GROUNDING <br />GROUND ROD GROUND BUS BAR <br />6 <br />DISTRIBUTION EQUIPMENT <br />SWITCHBOARD <br />D 1 <br />I <br />I I <br />L— <br />HOUSEKEEPING PAD (TYPICAL, REQUIRED BUT NOT SHOWN ON PLANS) <br />INCOMING OR'MAIN' SECTION <br />` --- DISTRIBUTION SECTION <br />rT _D - D D- -F� <br />MOTOR CONTROL CENTER <br />FUTURE SECTION <br />; <br />DISTRIBUTION SECTION <br />INCOMING SECTION <br />-- --- -- - --- -- HOUSEKEEPING PAD (TYPICAL, REQUIRED BUT NOT SHOWN ON PLANS) <br />PANELBOARD <br />NAME FRONT OF PANEL <br />—_ -WALL <br />RECESSED MOUNTED <br />SURFACE MOUNTED <br />PANELBOARD/SWITCHBOARD NAMING <br />BLDG-E1 MDPHAI <br />T 1-- A,B,C... DESIGNATOR DISTINGUISHES ROOM OR ROOM PANEL SERVED FROM <br />1,2,3... DESIGNATOR DISTINGUISHES INDIVIDUAL PANEUSWITCHBOARD <br />H - 480Y/277V <br />L - 208Y/120V <br />I <br />L NOTHING INDICATES LIGHTING/RECEPTACLE PANEL BRANCH PANEL <br />AV - AUDIO VISUAL PANEL <br />DM DIMMING PANEL <br />DP DISTRIBUTION PANEL <br />EV ELECTRIC VEHICLE CHARGING PANEL <br />GDP GENERATOR DISTRIBUTION PANEL <br />GSB - GENERATOR SWITCHBOARD <br />K - KITCHEN PANEL <br />LC LOAD CENTER <br />LCP LIGHTING CONTROL PANEL <br />MC METER CENTER <br />MCC MOTOR CONTROL CENTER <br />MDP - MAIN DISTRIBUTION PANEL (SERVICE ENTRANCE) <br />MSB - MAIN SWITCHBOARD (SERVICE ENTRANCE) <br />PDU POWER DISTRIBUTION UNIT <br />SB - SWITCHBOARD <br />ST SHUNT TRIP PANEL <br />T - TENANT PANEL <br />TC - TELECOMMUNICATIONS PANEL <br />SC - SHOW CONTROL PANEL <br />R - RIDE POWER PANEL <br />INDICATES WHICH FLOOR PANEL IS LOCATED ON (IF REQUIRED) <br />- NOTHING INDICATES NORMAL <br />LS - LIFE SAFETY LOADS (HEALTHCARE NEC ARTICLE 517) <br />CR - CRITICAL LOADS (HEALTHCARE NEC ARTICLE 517) <br />EQ - EQUIPMENT LOADS (HEALTHCARE NEC ARTICLE 517) <br />N - NORMAL LOADS (HEALTHCARE) <br />--- INDICATES WHICH BUILDING/AREA PANEL IS LOCATED IN (IF REQUIRED) <br />NAME TRANSFORMER <br />FLOOR MOUNTED TRANSFORMER, NUMBER INDICATES KVA RATING <br />HOUSEKEEPING PAD (TYPICAL, REQUIRED BUT NOT SHOWN ON PLANS) <br />--- INDICATES TRANSFORMER IS SUSPENDED <br />BLDG-TE1DPHA1 TRANSFORMER DESIGNATION <br />T INDICATES PANEL SERVED <br />- INDICATES TRANSFORMER <br />-- INDICATES WHICH BUILDING/AREA TRANSFORMER IS LOCATED IN (IF <br />---- REQUIRED) -------..._.. <br />NAME TRANSFER SWITCH <br />BLDG-ATSE1HA1 TRANSFER SWITCH DESIGNATION <br />- INDICATES PANEL SERVED <br />— - - INDICATES TRANSFER SWITCH <br />ATS - AUTOMATIC TRANSFER SWITCH <br />MTS - MANUAL TRANSFER SWITCH <br />INDICATES WHICH BUILDING/AREA AUTOMATIC TRANSFER SWITCH IS <br />LOCATED IN (IF REQUIRED) <br />TAGS AND CALL OUT SYMBOLS <br />SECTION CALLOUT <br />POINT OF CONNECTION <br />1 SECTION DESIGNATION POINT OF DEMARCATION <br />��oXl -SHEET NUMBER <br />REVISION CALLOUT <br />DETAIL CALLOUT <br />DETAIL DESIGNATION <br />-� X ,` KEYNOTE CALLOUT <br />�,XXXXj` mot- SHEET NUMBER <br />DEMOLITION <br />< R > <br />EXISTING TO BE REMOVED <br />< X > <br />EXISTING TO REMAIN <br />< RL > <br />EXISTING TO BE RELOCATED <br />< NL > <br />EXISTING - NEW LOCATION <br />-- ` -' <br />DEMOLITION CONDUIT <br />i <br />DEMOLITION EQUIPMENT <br />CIRCUITING <br />B_LDG-E1 MDPHA-1 3#12,#12G,314"C <br />CIRCUIT NUMBER T CONDUIT SIZE <br />-- - - PANEL DESIGNATION GROUND CONDUCTOR QUANTITY AND SIZE <br />-- CIRCUIT CONDUCTOR QUANTITY AND SIZE <br />APPLICABLE CODES & STANDARDS <br />FLORIDA BUILDING CODE - 7TH EDITION (2020), BUILDING <br />FLORIDA BUILDING CODE - 7TH EDITION (2020), EXISTING BUILDING <br />FLORIDA BUILDING CODE - 7TH EDITION (2020), FUEL GAS <br />FLORIDA FIRE PREVENTION CODE - 7TH EDITION (2020) <br />FGI GUIDELINES FOR DESIGN AND CONSTRUCTION OF RESIDENTIAL HEALTH, CARE AND SUPPORT <br />FACILITIES - 2018 EDITION <br />NATIONAL FIRE PROTECTION ASSOCIATION <br />NFPA 31, 2016 EDITION, STANDARD FOR THE INSTALLATION OF OIL -BURNING EQUIPMENT <br />NFPA 37, 2018 EDITION, STANDARD FOR THE INSTALLATION AND USE OF STATIONARY COMBUSTION <br />ENGINES AND GAS TURBINES <br />NFPA 54, 2018 EDITION, NATIONAL FUEL GAS CODE <br />NFPA 70,2017 EDITION, NATIONAL ELECTRICAL CODE <br />NFPA 72,2016 EDITION, NATIONAL FIRE ALARM AND SIGNALING CODE <br />NFPA 99, 2018 EDITION, HEALTH CARE FACILITIES CODE <br />NFPA 101, 2018 EDITION, THE LIFE SAFETY CODE (FLORIDA-SPECIFIC EDITION) <br />NFPA 110, 2016 EDITION, STANDARD FOR EMERGENCY AND STANDBY POWER SYSTEMS <br />NFPA 170, 2015 EDITION, STANDARD FOR FIRE SAFETY AND EMERGENCY SYMBOLS <br />NFPA 241, 2013 EDITION, STANDARD FOR SAFEGUARDING CONSTRUCTION, ALTERATION AND DEMOLITION <br />OPERATIONS <br />NFPA 704, 2017 EDITION, STANDARD SYSTEM FOR THE IDENTIFICATION OF THE HAZARDS OF MATERIALS <br />FOR EMERGENCY RESPONSE <br />INDUSTRY STANDARDS AND TESTING COMPANIES <br />UNDERWRITERS LABORATORIES INC. (UL) <br />AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE) <br />AMERICAN SOCIETY FOR TESTING MATERIALS (ASTM) <br />NOTE: THIS LIST IS NOT COMPREHENSIVE. THE CODES, GUIDELINES, AND STANDARDS <br />NOT REFERENCED HERE MAY BE APPLICABLE TO THIS PROJECT. <br />E <br />chapuis design group <br />architecture.pa <br />510 VONDERBURG DR. SUITE 216 <br />BRANDON, FL 33511 <br />Tel. 813-667-2340 <br />CGDPA - FL # AA-26003049 <br />exp U.S. Services Inc. <br />2601 Westhall Lane <br />Maitland, FL 32751 <br />USA <br />wexww.exp.com <br />�S��i <br />Project #: #22016657 <br />Cert of Auth: 29701 <br />� <br />PROJECT FOR <br />D ADVENTHEALTH - <br />ZEPHYRHILLS <br />ZL <br />PCU REFRESH <br />7050 Gall Blvd. <br />Zephyrhills, FL 33541 <br />AHCA CLIENT CODE I FILE NUMBER: N/A <br />I <br />1 9/8/2022 ADDENDUM 1 <br />MARK DATE DESCRIPTION <br />PROJECT NUMBER 042-22.236.01 <br />ORIGINAL ISSUE AUGUST 26, 2022 - <br />PROJECT MANAGERITEC - <br />PROJECT DESIGNER TTEC <br />PROJECT ARCHITECT THOMAS E. CHAPUIS - AR97109 <br />B LANDSCAPE ARCHITECT' N/A <br />CIVIL ENGINEER, N/A <br />STRUCTURAL ENGINEER N/A - - <br />MECHANICAL ENGINEER TIMOTHY P. PENNOCK - PE54516 <br />ELECTRICAL ENGINEER CHARLES T. ALEXANDER - PE76422 -- <br />INTERIOR DESIGNER CDG <br />EQUIPMENT PLANNER N/A <br />DRAWN BY t MWH -- - - <br />1. A <br />`��Q`�' '•L�GENgF •• '��jO �i <br />V No. 76422 <br />_ ft'A <br />O °• STATE OF 1(/` <br />S'ONA `,��```�. <br />ELECTRICAL <br />LEGENDS AND <br />A NOTES <br />SCALE' 12" = V-0" <br />E=001 <br />2 <br />3 <br />4 <br />5 <br />11 <br />Project Status <br />