Laserfiche WebLink
3 <br />I I I I ..IV 1l1'. LL. I!_. I. L_ "1-1. I... .. <br />2 <br />UI <br />ml <br />QI <br />4,1 <br />.I.11LAt 7, C, bNT <br />�■ <br />SECTION - 061643 - GYPSUM SHEATHING <br />A. SUMMARY: <br />1. SHEATHING USED IN LIEU OF PLYWOOD IN NON-COMBUSTIBLE BUILDING <br />CONSTRUCTION. <br />B. MATERIALS <br />1. SCREWS: GALVANIZED; SELF -DRILLING; SELF -DRILLING, BUGLE HEAD SCREWS; <br />MINIMUM 1-1/4 INCH LONG. <br />2, GYPSUM SHEATHING: ONE OF THE FOLLOWING: <br />a. G-P GYPSUM CORPORATION "DENS -GLASS GOLD;" GLASS MAT FACED; ASTM C1177; 112 <br />INCH THICK <br />b. USG FIBEROCK BRAND SHEATHING WITH AQUA-TOUGH(TM); 1/2 INCH THICK. <br />C. INSTALLATION: <br />1. INSTALL SQUARE EDGE BOARDS PARALLEL OR PERPENDICULAR TO FRAMING. INSTALL <br />BOARDS PARALLEL TO FRAMING AT FIRE RATED WALLS, APPLY SHEATHING WITH <br />JOINTS STAGGERED. ALL EDGES SHALL BE FIRMLY SUPPORTED. <br />2. INSTALL SHEATHING WITH COATING TOWARDS EXTERIOR. <br />3. SCREW TO FRAMING. SPACE FASTENERS 8 INCHES O.C. IN FIELD AND 4 INCHES O.C. AT <br />ENDS ALONG EACH FRAMING MEMBER. <br />4. DO NOT BRIDGE EXPANSION OR SEISMIC JOINTS. <br />RIM <br />., Y <br />0$TP,iE­::­­:1 <br />072100 THERMAL INSULATION <br />A. SUMMARY: BUILDING INSULATION WHEN INDICATED ON THE DRAWINGS. <br />B. MATERIALS <br />1. UNFACED BATT AND BLANKET INSULATION: ASTM C665, TYPE I; PREFORMED UNFACED <br />GLASS FIBER ROLL; FLAME SPREAD OF 25 OR LESS AND SMOKE DEVELOPED OF 50 OR <br />LESS WHEN TESTED IN ACCORDANCE WITH ASTM E84;OVERSIZE WIDTHS FOR <br />FRICTION -FIT BETWEEN METAL FRAMING. <br />2. BOARD INSULATION: EXTRUDED POLYSTYRENE; DOW CHEMICAL COMPANY <br />"STYROFOAM" OR OWENS CORNING "FOAMULAR 250." <br />C. ACCESSORIES: <br />1. SEPARATE VAPOR BARRIER FOR BATT INSULATION: FOIL SCRIM KRAFT FSK 25; FLAME <br />SPREAD OF 25 OR LESS AND A SMOKE DEVELOPED OF 50 OR LESS WHEN TESTED IN <br />ACCORDANCE WITH ASTM E84. <br />2. TAPE: TO MATCH INSULATION FACING; 2 INCH WIDTH. <br />3. ACOUSTIC INSULATION: SEE SECTION 098100. <br />D. INSTALLATION: <br />1. INSTALL INSULATION IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS <br />AND AS INDICATED. <br />2. TRIM INSULATION NEATLY TO FIT SPACES. INSTALL WITHOUT GAPS OR VOIDS. <br />3. INSTALLATION OF THERMAL BATT INSULATION: <br />a. INSTALL INSULATION WITH VAPOR BARRIER TOWARD WARM SIDE OF BUILDING SPACES. <br />VAPOR BARRIER SHALL BE CONTINUOUS. TAPE SEAL TEARS OR CUTS IN VAPOR BARRIER. <br />b. AT METAL STUD FRAMING, INSERT THE INSULATION EDGES TIGHTLY INTO THE STUD <br />CHANNELS FOR A FRICTION FIT. WHERE INSULATION BUTTS THE BACKSIDE OF STUD <br />CHANNELS, CONTINUOUSLY TAPE INSULATION FLANGES TO THE EXPOSED METAL STUD <br />FLANGE. <br />c. MECHANICAL FASTENING: <br />4. AT LOCATIONS WHERE NO FRAMING IS PRESENT TO SUPPORT THE INSULATION, <br />PROVIDE METAL IMPALING PINS AND RETAINERS TO HOLD THE INSULATION FIRMLY IN <br />POSITION. <br />5. MECHANICALLY OR ADHESIVELY BOND THE RETAINING PINS TO THE SUBSTRATE IN <br />ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. <br />6. SPACE PINS AT MAXIMUM 24 INCHES ON CENTER ALONG THE EDGES AND WITHIN THE <br />FIELD OF THE BLANKET. PLACE EDGE PINS WITHIN 6 INCHES FROM THE EDGE OF THE <br />BATT. <br />a. PACK BATT INSULATION IN SHIM SPACES AT PERIMETER OF WINDOW ASSEMBLY TO <br />MAINTAIN CONTINUITY OF THERMAL BARRIER. <br />7. SEPARATE VAPOR BARRIER INSTALLATION: <br />a. INSTALL SEPARATE VAPOR BARRIER OVER UNFACED INSULATION. <br />b. INSTALL VAPOR BARRIER TOWARD WARM SIDE OF BUILDING SPACES. <br />c. VAPOR BARRIER SHALL BE CONTINUOUS. <br />d. AT LOCATIONS WHERE INSULATION IS MECHANICALLY FASTENED BY IMPALING PINS, <br />PLACE VAPOR RETARDER OVER IMPALING PINS AND HOLD IN POSITION WITH ADDITIONAL <br />RETAINERS. THE INSTALLATION SHALL PRESENT A TIGHT, CONTINUOUS, AND WRINKLE <br />FREE APPEARANCE. <br />e. AT LIGHT GA SUPPORT FRAMING, SECURE TO STUDS WITH DOUBLE STICK TAPE OR <br />SPRAY ADHESIVE. <br />f. LAP JOINTS IN VAPOR BARRIER 2 INCHES, EXCEPT PROVIDE TAPE SEALED JOINTS AT <br />LOCATIONS WHERE VAPOR BARRIER WILL REMAIN EXPOSED IN THE FINISHED WORK. <br />g. TAPE SEAL VAPOR BARRIER TO ADJACENT CONSTRUCTION AT PERIMETER EDGES. <br />h. TAPE AND SEAL TEARS OR CUTS IN VAPOR BARRIER. <br />A. "R" VALUE SCHEDULE: <br />1. BATT INSULATION: PROVIDE MINIMUM 6 INCH INSULATION THICKNESS (R19) TO FILL <br />STUD CAVITY OR GREATER TO MATCH EXISTING IN SIMILAR APPLICATIONS, OR AS <br />INDICATED ON THE DRAWINGS. <br />2. RIGID INSULATION: PROVIDE MINIMUM 2 INCH INSULATION THICKNESS (R10) OR TO <br />MATCH EXISTING IN SIMILAR APPLICATIONS. <br />APPLIED EXTERIOR FINISH SYSTEM DEFS 072401 DIRECT (DEFS) <br />A. SUMMARY: <br />1. WHERE CEMENT PLASTER IS INDICATED ON THE DRAWINGS OVER EXISTING CMU, <br />PROVIDE DIRECT APPLIED EXTERIOR FINISH SYSTEM (DEFS) OVER EXISTING <br />CONCRETE MASONRY UNITS AS SPECIFIED. <br />B. APPLICATOR QUALIFICATIONS: <br />1. MINIMUM OF 5 YEARS EXPERIENCE IN THE APPLICATION OF DEFS OF SIMILAR SCOPE <br />TO THE WORK INDICATED. <br />2. INSTALLER SHALL HAVE BEEN TRAINED BY THE PRODUCT MANUFACTURER PRIOR TO <br />BIDDING, AND SHALL BE CURRENTLY APPROVED BY THE MANUFACTURER TO INSTALL <br />WARRANTABLE DEFS SYSTEM AS SPECIFIED. <br />C. PROTECTION: PROTECT ADJACENT MATERIALS AND THIS SYSTEM FROM DAMAGE DURING <br />INSTALLATION, WHILE CURING OR WHEN UNATTENDED. <br />D. APPROVED MANUFACTURERS: <br />1. DRYVIT SYSTEMS INC. <br />2. STO INDUSTRIES, INC. <br />3. SENERGY, INC. <br />E. MATERIALS: <br />1. PROVIDE MANUFACTURER'S STANDARD MATERIALS AS RECOMMENDED FOR THE <br />INSTALLATION. <br />2. BASE COAT: MANUFACTURER'S STANDARD POLYMER MODIFIED CEMENTITIOUS BASE <br />COAT; MAXIMUM 30% CEMENT; DRY FACTORY PRE -MIXED FORMULA, OR <br />PRE -MEASURED PACKAGED MATERIALS FOR CONSISTENT SITE MIXING. <br />3. FINISH COAT: MANUFACTURER'S STANDARD; 100% ACRYLIC; CUSTOM INTEGRAL COLOR <br />AS SELECTED BY THE ARCHITECT; LISTED BY UNDERWRITER'S LABORATORIES, INC. AS <br />HAVING A FLAME SPREAD OF 25 OR LESS. <br />4. REINFORCING MESH: MANUFACTURER'S STANDARD ALKALINE RESISTANT OPEN WEAVE <br />GLASS FIBER MESH; STANDARD DUTY AND HEAVY DUTY. <br />5. SUBSTRATE MESH TAPE: ALKALINE RESISTANT OPEN WEAVE GLASS FIBER MESH <br />SURFACED ON ONE SIDE WITH PRESSURE SENSITIVE ADHESIVE; TYPE AS <br />RECOMMENDED BY SYSTEM MANUFACTURER. <br />6. DEFS TRIM: <br />a. PRODUCTS OF VINYL CORPORATION (800-648-4695) ARE LISTED AS A STANDARD OF <br />APPROVAL. SIMILAR AND EQUAL PRODUCTS BY PLASTIC COMPONENTS (800-327-7077) MAY <br />BE USED. FABRICATE FROM EXTERIOR GRADE VINYL; PROVIDE MANUFACTURER'S <br />STANDARD SPLICE PLATES AND CONNECTOR CLIPS FOR BUTT JOINT CONNECTIONS. <br />b. CORNER BEAD: CB158E. <br />F. INSTALLATION: <br />1. PROTECT ADJACENT SURFACES FROM CONTACT WITH OVERSPRAY AND SPATTER OF <br />PRIMERS, ADHESIVES, AND FINISH COATS. <br />2. AT CONCRETE AND CMU SURFACES TO RECEIVE FINISH COAT ONLY, REMOVE ALL DIRT, <br />DUST, FORM RELEASE AGENTS, EFFLORESCENCE, AND OTHER ELEMENTS WHICH <br />WOULD IMPAIR BOND. ACID ETCH WITH MURIATIC ACID. <br />3. INSTALL DEFS IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. <br />4. PROVIDE FINISH COAT ONLY OVER EXISTING CONCRETE BLOCK SURFACES AS <br />INDICATED ON THE DRAWINGS. <br />5. FINISH COATING SHALL BE APPLIED AS RECOMMENDED BY THE EXTERIOR INSULATION <br />AND FINISH SYSTEM MANUFACTURER. <br />Olvis"10, it r <br />011 <br />6. TROWEL APPLY SKIM COAT OF MANUFACTURER'S RECOMMENDED FIBER REINFORCED <br />POLYMER MODIFIED MORTAR TO OBTAIN SMOOTH AND FLAT SURFACES WITHIN A <br />TOLERANCE OF 1/8 INCH IN 10 FEET, AND TO FILL SURFACE IMPERFECTIONS. USE <br />BONDING AGENT AS NECESSARY FOR ADEQUATE BOND. <br />7. APPLY COLOR MATCH PRIMER. <br />8. PROVIDE FINISH COAT TO MATCH EXISTING. <br />G. CLEAN-UP: REMOVE DIRT AND STAINS FROM DEFS SURFACES AND ADJACENT SURFACES <br />WITHOUT DAMAGING FINISHES. <br />07241 EXTERIOR INSULATION AND FINISH SYSTEMS - CLASS PB <br />A. SUMMARY <br />1. THIS SECTION INCLUDES CLASS PB EXTERIOR INSULATION AND FINISH SYSTEM (EIFS) <br />[WITH DRAINAGE] APPLIED OVER SUBSTRATE AS INDICATED ON DRAWINGS. <br />a. USE, MANUFACTURER, EXTENT, TEXTURE AND COLOR ARE SUBJECT TO T-MOBILE REVIEW <br />AND APPROVAL <br />2. ACCEPTABLE SUBSTRATES FOR OUTSULATION SYSTEMS. <br />a. UNGLAZED BRICK, CEMENT PLASTER, CONCRETE, OR MASONRY. <br />b. EXTERIOR GRADE GYPSUM SHEATHING MEETING ASTM C79 REQUIREMENTS FOR <br />WATER-RESISTANT CORE OR TYPE X CORE AT THE TIME OF APPLICATION OF THE <br />OUTSULATION SYSTEM. <br />c. SILICONE TREATED GYPSUM CORE SHEATHING SURFACED WITH INORGANIC FIBERGLASS <br />MATS MEETING ASTM C1177. <br />d. EXTERIOR FIBER REINFORCED CEMENT AND CALCIUM SILICATE BOARDS. <br />e. APA EXTERIOR OR EXPOSURE 1 RATED PLYWOOD, GRADE C-D OR BETTER, NOMINAL 13 <br />MM (1/2 IN.), MINIMUM PLY. <br />f. APA EXPOSURE 1 RATED ORIENTED STRAND BOARD (OSB), NOMINAL 13 MM (1/2 IN.) <br />g. GALVANIZED EXPANDED METAL LATH 1.4 OR 1.8 KG/M2 (2.6 OR 3.3 LBS/YD2) INSTALLED <br />OVER A SOLID SUBSTRATE. <br />h. DEFLECTION OF SUBSTRATE SYSTEMS SHALL NOT EXCEED U240. <br />i. THE SLOPE OF INCLINED SURFACES SHALL NOT BE LESS THEN 6:12. <br />j. THE LENGTH OF INCLINED SURFACES SHALL NOT EXCEED 305 MM (121N). <br />B. PERFORMANCE REQUIREMENTS <br />1. CLASS PB EIFS: COMPLY WITH PERFORMANCE CHARACTERISTICS IN EIMA'S "EIMA <br />GUIDELINE SPECIFICATION FOR EXTERIOR INSULATION AND FINIS <br />H SYSTEMS, CLASS <br />FIB." <br />a. STANDARD IMPACT RESISITANCE: 25-49 INCH -LB (2.8-5.6 J) FOR AREAS ABOVE T-0." <br />b. HIGH IMPACT RESISTANCE: 90-150 INCH -LB (10.2 - 17 J) FOR AREAS BELOW T-0." <br />c. POSITIVE AND NEGATIVE WIND -LOAD PERFORMANCE: CAPABILITY TO WITHSTAND WIND <br />LOADS INDICATED WHEN TESTED PER ASTM E 330. <br />2. DRAINAGE: 3 SAMPLES CAPABLE OF DRAINING WATER, AND HAVING AN AVERAGE <br />MINIMUM TRUE DRAINAGE EFFICIENCY OF [90] PERCENT WHEN TESTED PER EIMA 200.2. <br />3. WATER -/WEATHER -RESISTIVE -BARRIER COATING: COMPLY WITH ICBO-ES AC24. <br />C. SUBMITTALS <br />1. PRODUCT DATA: FOR EACH PRODUCT INDICATED. <br />2. SHOP DRAWINGS: INCLUDE PLANS, ELEVATIONS, SECTIONS, DETAILS, PENETRATIONS, <br />TERMINATIONS, FASTENERS, AND ATTACHMENTS TO OTHER WORK. <br />3. SAMPLES: FOR EACH EIFS AND FOR EACH COLOR AND TEXTURE REQUIRED. <br />4. FIELD QUALITY -CONTROL TEST REPORTS. <br />5. PRODUCT [TEST REPORTS]. <br />6. MAINTENANCE DATA. <br />A. QUALITY ASSURANCE <br />1. INSTALLER QUALIFICATIONS: CERTIFIED IN WRITING BY EIFS MANUFACTURER TO <br />INSTALL MANUFACTURER'S SYSTEM USING TRAINED WORKERS. <br />2. SOURCE LIMITATIONS: OBTAIN EIFS THROUGH ONE SOURCE FROM A SINGLE EIFS <br />MANUFACTURER AND FROM SOURCES APPROVED BY EIFS MANUFACTURER AS <br />COMPATIBLE WITH SYSTEM COMPONENTS. <br />3. FIRE -TEST -RESPONSE CHARACTERISTICS: WHERE INDICATED, PROVIDE EIFS AND <br />SYSTEM COMPONENTS IDENTICAL TO THOSE OF EIFS AND SYSTEM COMPONENTS <br />TESTED PER TEST METHOD INDICATED BELOW BY UL OR ANOTHER TESTING AND <br />INSPECTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. IDENTIFY <br />PRODUCTS WITH APPROPRIATE MARKINGS OF APPLICABLE TESTING AND INSPECTING <br />AGENCY. <br />a. FLAME SPREAD OF INSULATION BOARD AND FINISH COATS: 25 OR LESS WHEN TESTED <br />INDIVIDUALLY PER ASTM E 84. <br />b. SMOKE DEVELOPED OF INSULATION BOARD AND FINISH COATS; 450 OR LESS WHEN <br />TESTED INDIVIDUALLY PER ASTM E 84. <br />E. MANUFACTURERS <br />1. AVAILABLE MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, <br />MANUFACTURERS OFFERING PRODUCTS THAT MAY BE INCORPORATED INTO THE <br />WORK INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING: <br />2. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE <br />PRODUCTS BY ONE OF THE FOLLOWING: <br />a. DRYVIT SYSTEMS, INC. <br />b. SENERGY INC.; SKW-MBT CONSTRUCTION CHEMICALS. <br />c. STO CORP. <br />3. BASIS -OF -DESIGN PRODUCT: THE DESIGN FOR EIFS[ WITH DRAINAGE] IS BASED ON <br />DRYVIT OUTSULATION SYSTEM REQUIREMENTS. SUBJECT TO COMPLIANCE WITH <br />REQUIREMENTS, PROVIDE THE NAMED PRODUCT OR A COMPARABLE PRODUCT BY ONE <br />OF THE FOLLOWING MANUFACTURERS LISTED ABOVE. <br />F. MATERIALS <br />1. COMPATIBILITY: PROVIDE SUBSTRATES, ADHESIVE, FASTENERS, BOARD INSULATION, <br />REINFORCING MESHES, BASE- AND FINISH -COAT SYSTEMS, SEALANTS, AND <br />ACCESSORIES THAT ARE COMPATIBLE WITH ONE ANOTHER AND APPROVED FOR USE <br />BY EIFS MANUFACTURER FOR PROJECT. <br />2. WATER -/WEATHER -RESISTIVE -BARRIER COATING: FORMULATION AND ACCESSORIES <br />DESIGNED FOR INDICATED USE. <br />3. PRIMER/SEALER: SUBSTRATE CONDITIONER DESIGNED TO SEAL SUBSTRATES FROM <br />MOISTURE PENETRATION AND TO IMPROVE THE BOND BETWEEN SUBSTRATE OF TYPE <br />INDICATED AND ADHESIVE USED FOR APPLICATION OF INSULATION, <br />4. DRAINAGE MAT: DESIGNED TO DRAIN INCIDENTAL MOISTURE BY GRAVITY; EIFS <br />MANUFACTURER'S STANDARD OR PRODUCT RECOMMENDED IN WRITING BY EIFS <br />MANUFACTURER [WITH MANUFACTURER'S STANDARD CORROSION -RESISTANT <br />MECHANICAL FASTENERS SUITABLE FOR INTENDED SUBSTRATE]. <br />] <br />5. SPACERS: FURRING STRIPS; EIFS MANUFACTURER'S STANDARD OR PRODUCT <br />RECOMMENDED IN WRITING BY EIFS MANUFACTURER [WITH MANUFACTURER'S <br />STANDARD CORROSION -RESISTANT MECHANICAL FASTENERS SUITABLE FOR <br />INTENDED SUBSTRATE]. <br />6, ADHESIVE FOR APPLICATION OF INSULATION: MFR'S STANDARD. <br />7. MOLDED, RIGID CELLULAR POLYSTYRENE BOARD INSULATION: COMPLY WITH EIFS <br />MANUFACTURER'S REQUIREMENTS, ASTM C 578 FOR TYPE I, AND EIMA'S "EIMA <br />GUIDELINE SPECIFICATION FOR EXPANDED POLYSTYRENE (EPS) INSULATION BOARD." <br />a. CHANNELED BOARD INSULATION: EIFS MANUFACTURER'S STANDARD <br />FACTORY -FABRICATED PROFILE WITH LINEAR VERTICAL DRAINAGE CHANNELS, SLOTS, OR <br />WAVES ON THE BACK SIDE OF BOARD. <br />8. REINFORCING MESH: BALANCED, ALKALI -RESISTANT, OPEN -WEAVE GLASS -FIBER MESH <br />TREATED FOR COMPATIBILITY WITH OTHER EIFS MATERIALS AND COMPLYING WITH <br />EIMA 105.01 AND ASTM D 578. <br />a. STANDARD -IMPACT REINFORCING MESH: NOT LESS THAN [4.0 OZ./SQ. YD. (136 G/SQ. M)] <br />b. HIGH -IMPACT REINFORCING MESH: NOT LESS THAN [15 OZ./ SQ. YD. <br />(509 G/SQ. M)] T-0" DOWN TO FF. <br />c. DETAIL REINFORCING MESH: NOT LESS THAN [4.0 OZ./SQ. YD. (136 G/SQ. M)]. <br />d. CORNER REINFORCING MESH: NOT LESS THAN [7.2 OZ./SQ. YD. (244 G/SQ. M)]. <br />9. BASE -COAT MATERIALS: STANDARD MIXTURE. <br />10. WATERPROOF ADHESIVE/BASE-COAT MATERIALS: WATERPROOF MIXTURE. <br />11. PRIMER: FACTORY -MIXED ELASTOMERIC-POLYMER PRIMER FOR PREPARING <br />BASE -COAT SURFACE FOR APPLICATION OF FINISH COAT. <br />12. FINISH -COAT MATERIALS: [STANDARD ACRYLIC -BASED COATING WITH ENHANCED <br />MILDEW RESISTANCE].COLORS, TEXTURES, AND PATTERNS: REFERENCE EXTERIOR <br />FINISH SCHEDULE ON DRAWINGS. <br />13. MECHANICAL FASTENERS: CORROSION -RESISTANT FASTENERS CONSISTING OF <br />THERMAL CAP, STANDARD WASHER AND SHAFT ATTACHMENTS, AND FASTENER <br />SUITABLE FOR SUBSTRATE. <br />14. TRIM ACCESSORIES: MANUFACTURED FROM UV -STABILIZED PVC AND COMPLYING <br />WITH ASTM D 1784 AND ASTM C 1063. <br />A. INSTALLATION <br />1. GENERAL: COMPLY WITH ASTM C 1397 AND EIFS MANUFACTURER'S WRITTEN <br />INSTRUCTIONS FOR INSTALLATION OF EIFS AS APPLICABLE TO EACH TYPE OF <br />SUBSTRATE INDICATED. <br />2. INSULATION: [ADHESIVELY AND MECHANICALLY] ATTACH TO SUBSTRATE. <br />3. EXPANSION JOINTS: INSTALL AT LOCATIONS INDICATED; WHERE REQUIRED BY EIFS <br />MANUFACTURER; WHERE EXPANSION JOINTS ARE INDICATED IN SUBSTRATES BEHIND <br />EIFS; WHERE EIFS ADJOIN DISSIMILAR SUBSTRATES, MATERIALS, AND CONSTRUCTION; <br />AT FLOOR LINES IN MULTILEVEL WOOD -FRAMED CONSTRUCTION; AND WHERE WALL <br />HEIGHT CHANGES. <br />771 <br />- D I■ <br />4. BASE COAT: APPLY TO EXPOSED SURFACES OF INSULATION IN MINIMUM THICKNESS <br />RECOMMENDED IN WRITING BY EIFS MANUFACTURER, BUT NOT LESS THAN [1/16-INCH <br />(1.6-MM)] DRY -COAT THICKNESS. <br />5. REINFORCING MESH: COMPLETELY EMBED MESH IN WET BASE COAT, APPLYING <br />ADDITIONAL BASE -COAT MATERIAL IF NECESSARY, SO REINFORCING -MESH COLOR AND <br />PATTERN ARE NOT VISIBLE. <br />6. DOUBLE -LAYER REINFORCING MESH APPLICATION: WHERE INDICATED, APPLY SECOND <br />BASE COAT AND SECOND LAYER OF [STANDARD] IMPACT REINFORCING MESH. <br />7. DOUBLE BASE -COAT APPLICATION: WHERE INDICATED, APPLY IN SAME MANNER AND <br />THICKNESS AS FIRST APPLICATION EXCEPT WITHOUT REINFORCING MESH. <br />8, FINISH COAT: APPLY OVER DRY [PRIMER] AND [BASE COAT], MAINTAINING A WET EDGE <br />AT ALL TIMES FOR UNIFORM APPEARANCE, IN THICKNESS REQUIRED BY EIFS <br />MANUFACTURER TO PRODUCE A UNIFORM FINISH OF COLOR AND TEXTURE MATCHING <br />APPROVED SAMPLE AND FREE OF COLD JOINTS, SHADOW LINES, AND TEXTURE <br />VARIATIONS. (FINE SAND TEXTURED FINISH). <br />H. FIELD QUALITY CONTROL <br />1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER APPLICATION OF THE <br />OUTSULATION MATERIALS. <br />2. MANUFACTURER ASSUMES NO RESPONSIBILITY FOR ON -SITE INSPECTIONS OR <br />APPLICATION OF ITS PRODUCTS. <br />3. IF REQUIRED, THE CONTRACTOR SHALL CERTIFY IN WRITING THE QUALITY OF WORK <br />PERFORMED RELATIVE TO THE SUBSTRATE SYSTEM,DETAILS, INSTALLATION <br />PROCEDURES, WORKMANSHIP AND AS TO THE SPECIFIC PRODUCTS USED. <br />4. IF REQUIRED, THE EPS SUPPLIER SHALL CERTIFY IN WRITING THA THE EPS MEETS <br />MANUFACTURER'S SPECIFICATIONS. <br />5. IF REQUIRED, THE SEALANT CONTRACTOR SHALL CERTIFY IN WRITING THAT THE <br />SEALANT APPLICATION IS IN ACCORDANCE WITH THE SEALANT MANUFACTURER'S AND <br />MANUFACTURER'S RECOMMENDATIONS. <br />I. CLEANING <br />1. ALL EXCESS OUTSULATION SYSTEM MATERIALS SHALL BE REMOVED FROM THE JOB <br />SITE BY THE CONTRACTOR IN ACCORDANCE WITH CONTRACT PROVISIONS AND AS <br />REQUIRED BY APPLICABLE LAW. <br />2. ALL SURROUNDING AREAS, WHERE THE OUTSULATION SYSTEM HAS BEEN INSTALLED, <br />SHALL BE LEFT FREE OF DEBRIS AND FOREIGN SUBSTANCES RESULTING FROM THE <br />CONTRACTOR'S WORK. <br />J. PROTECTION <br />1. THE OUTSULATION SYSTEM SHALL BE PROTECTED FROM INCLEMENT WEATHER AND <br />OTHER SOURCES OF DAMAGE UNTIL DRY AND PERMANENT PROTECTION IN THE FORM <br />OF FLASHINGS, SEALANTS, ETC. ARE INSTALLED. <br />SECTION 07415 - COMPOSITE WALL PANELS OR BRAKE METAL (IF NOTED ON DRAWINGS) <br />A. PERFORMANCE REQUIREMENTS <br />1. DELEGATED DESIGN: DESIGN METAL -FACED COMPOSITE WALL PANEL OR BRAKE <br />METAL ASSEMBLY, INCLUDING COMPREHENSIVE ENGINEERING ANALYSIS BY A <br />QUALIFIED PROFESSIONAL ENGINEER.STRUCTURAL PERFORMANCE: PROVIDE <br />METAL -FACED COMPOSITE WALL PANEL ASSEMBLIES CAPABLE OF WITHSTANDING THE <br />EFFECTS OF THE FOLLOWING LOADS AND STRESSES WITHIN LIMITS AND UNDER <br />CONDITIONS INDICATED, BASED ON TESTING ACCORDING TO ASTM E 330: <br />2. WIND LOADS: DETERMINE LOADS BASED ON THE FOLLOWING MINIMUM DESIGN WIND <br />PRESSURES: 20 LBF/SQ. FT. UNIFORM PRESSURE OF ACTING (957 PA) INWARD OR <br />OUTWARD. <br />3. DEFLECTION LIMITS: METAL -FACED COMPOSITE WALL PANEL ASSEMBLIES SHALL <br />WITHSTAND WIND LOADS WITH HORIZONTAL DEFLECTIONS NO GREATER THAN [1/175 <br />OF THE SPAN AT THE PERIMETER AND 1/60 OF THE SPAN ANYWHERE IN THE PANEL] < <br />OF THE SPAN. <br />B. PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED. <br />1. SHOP DRAWINGS: SHOW FABRICATION AND INSTALLATION LAYOUTS OF METAL -FACED <br />COMPOSITE WALL PANELS; DETAILS OF EDGE CONDITIONS, JOINTS, PANEL PROFILES, <br />CORNERS, ANCHORAGES, ATTACHMENT SYSTEM, TRIM, FLASHINGS, CLOSURES, AND <br />ACCESSORIES; AND SPECIAL DETAILS. DISTINGUISH AMONG FACTORY-, SHOP-, AND <br />FIELD -ASSEMBLED WORK. SAMPLES: FOR EACH TYPE OF EXPOSED FINISH REQUIRED. <br />2. DELEGATED -DESIGN SUBMITTAL: FOR METAL -FACED COMPOSITE WALL PANEL <br />ASSEMBLY INDICATED TO COMPLY WITH PERFORMANCE REQUIREMENTS AND DESIGN <br />CRITERIA, INCLUDING ANALYSIS DATA AND CALCULATIONS SIGNED AND SEALED BY THE <br />QUALIFIED PROFESSIONAL ENGINEER RESPONSIBLE FOR THEIR PREPARATION. <br />COORDINATION DRAWINGS: EXTERIOR ELEVATIONS, DRAWN TO SCALE, ON WHICH THE <br />FOLLOWING ITEMS ARE SHOWN AND COORDINATED WITH EACH OTHER. <br />C. QUALITY ASSURANCE <br />1. MANUFACTURER QUALIFICATIONS: MINIMUM 5 YEARS CONTINUOUS EXPERIENCE <br />MANUFACTURING THE PANEL MATERIAL SPECIFIED, WITH NO OUTSOURCED <br />PRODUCTION PROCESSES.ISO 9001 CERTIFIED. <br />2. FABRICATOR QUALIFICATIONS: MINIMUM 3 YEARS EXPERIENCE ON PROJECTS OF <br />COMPARABLE SCOPE AND SCALE, AND CAPABLE OF PROVIDING FIELD SERVICE <br />REPRESENTATION DURING CONSTRUCTION. INSTALLER QUALIFICATIONS: MINIMUM 3 <br />YEARS EXPERIENCE ON PROJECTS OF COMPARABLE SCOPE AND SCALE, AND CAPABLE <br />OF PROVIDING FIELD SERVICE REPRESENTATION DURING CONSTRUCTION. <br />3. FIRE -RESISTANCE RATINGS: WHERE INDICATED, PR VIDE METAL -FACED COMP <br />OSITE <br />WALL PANELS IDENTICAL TO THOSE OF ASSEMBLIES TESTED FOR FIRE RESISTANCE <br />PER ASTM E 119 BY A QUALIFIED TESTING AGENCY. IDENTIFY PRODUCTS WITH <br />APPROPRIATE MARKINGS OF APPLICABLE TESTING AGENCY. <br />D. WARRANTY <br />1. SPECIAL WARRANTY: MANUFACTURER'S STANDARD FORM IN WHICH MANUFACTURER <br />AGREES TO REPAIR OR REPLACE COMPONENTS OF METAL -FACED COMPOSITE WALL <br />PANEL ASSEMBLIES THAT FAIL IN MATERIALS OR WORKMANSHIP WITHIN SPECIFIED <br />WARRANTY PERIOD. <br />2. WARRANTY PERIOD: [TEN] YEARS FROM DATE OF SUBSTANTIAL COMPLETION. <br />3. SPECIAL WARRANTY ON PANEL FINISHES: MANUFACTURER'S STANDARD FORM IN <br />WHICH MANUFACTURER AGREES TO REPAIR FINISH OR REPLACE METAL -FACED <br />COMPOSITE WALL PANELS THAT SHOW EVIDENCE OF DETERIORATION OF FACTORY <br />-APPLIED FINISHES WITHIN SPECIFIED WARRANTY PERIOD. <br />4. FINISH WARRANTY PERIOD: [20] > YEARS FROM DATE OF SUBSTANTIAL COMPLETION. <br />E. PRODUCTS <br />1. PANEL MATERIALS. <br />a. ALUMINUM SHEET: COIL -COATED SHEET, ASTM B 209), ALLOY AS STANDARD WITH <br />MANUFACTURER, WITH TEMPER AS REQUIRED TO SUIT FORMING OPERATIONS AND <br />STRUCTURAL PERFORMANCE REQUIRED. <br />2. SURFACE: SMOOTH, FLAT FINISH. <br />3. EXPOSED COIL -COATED FINISHES: <br />a. TWO -COAT FEVE FLUOROPOLYMER: AAMA 620. <br />b. TWO -COAT PVDF FLUOROPOLYMER: AAMA 620. <br />4. EXPOSED ANODIZED FINISHES: <br />a. COLOR ANODIC FINISH: AAMA 611, [AA-M12C22A42/A44, CLASS I, 0.018 MM] <br />[AA-M12C22A32/A34, CLASS 11, 0.010 MM] OR THICKER. <br />b. CONCEALED FINISH: APPLY PRETREATMENT AND MANUFACTURER'S STANDARD WHITE OR <br />LIGHT-COLORED ACRYLIC OR POLYESTER BACKER FINISH, CONSISTING OF PRIME COAT <br />AND WASH COAT 0.5 MIL WITH A MINIMUM TOTAL DRY FILM THICKNESS OF. (0.013 MM) <br />5. PANEL SEALANTS: ASTM C 920. <br />F. MISCELLANEOUS METAL FRAMING <br />1. MISCELLANEOUS METAL FRAMING, GENERAL: ASTM C 645, COLD -FORMED <br />METALLIC -COATED STEEL SHEET, [ASTM A 653 /A 653M, G40 (Z120) HOT -DIP <br />GALVANIZED] OR COATING WITH EQUIVALENT CORROSION RESISTANCE UNLESS <br />OTHERWISE INDICATED. <br />2. SUBGIRTS: MANUFACTURER'S STANDARD C- OR Z-SHAPED SECTIONS 0.064-INCH <br />(1.63-MM) NOMINAL THICKNESS. <br />3. ZEE CLIPS: 0.079-INCH (2.01-MM) NOMINAL THICKNESS. <br />4. BASE OR SILL [ANGLES] [CHANNELS]: 0.079-INCH (2.01-MM) NOMINAL THICKNESS. <br />5. HAT -SHAPED, RIGID FURRING CHANNELS: NOMINAL THICKNESS: [AS INDICATED] [AS <br />REQUIRED TO MEET PERFORMANCE REQUIREMENTS] [0.025 INCH (0.64MM)] > DEPTH: <br />[AS INDICATED] [1-1/2 INCHES (38 MM)] <br />6. COLD -ROLLED FURRING CHANNELS: MINIMUM 1/2-INCH- (13-MM-) WIDE FLANGE. <br />NOMINAL THICKNESS: [AS INDICATED] [AS REQUIRED TO MEET PERFORMANCE <br />REQUIREMENTS] [0.064 INCH (1.63MM)]< DEPTH: [AS INDICATED] [ 3/4 INCH (19 MM)] < <br />7, FURRING BRACKETS: ADJUSTABLE, CORRUGATED -EDGE TYPE OF STEEL SHEET WITH <br />NOMINAL THICKNESS OF 0.040 INCH (1.02. MM) <br />8. TIE WIRE: ASTM A 641/A 641M, CLASS 1 ZINC COATING, SOFT TEMPER, <br />0.062-INCH-(1.57-MM-) DIAMETER WIRE, OR DOUBLE STRAND OF 0.048-INCH- (1.22-MM-) <br />DIAMETER WIRE. <br />G. MISCELLANEOUS MATERIALS <br />1. ALUMINUM EXTRUSIONS: ASTM B 221 <br />2. FASTENERS: SELF -TAPPING SCREWS, BOLTS, NUTS, SELF-LOCKING RIVETS AND BOLTS, <br />END -WELDED STUDS, AND OTHER SUITABLE FASTENERS DESIGNED TO WITHSTAND <br />DESIGN LOADS. PROVIDE EXPOSED FASTENERS WITH HEADS MATCHING COLOR OF <br />METAL -FACED COMPOSITE WALL PANELS BY MEANS OF PLASTIC CAPS OR <br />FACTORY -APPLIED COATING. PROVIDE EPDM, PVC, OR NEOPRENE SEALING WASHERS. <br />NO VISIBLE MECHANICAL FASTENERS. <br />tt <br />H. METAL -FACED COMPOSITE WALL PANELS OR BRAKE METAL <br />1. GENERAL: PROVIDE FACTORY -FORMED AND -ASSEMBLED, METAL -FACED COMPOSITE <br />WALL PANELS FABRICATED FROM TWO METAL FACINGS BONDED, USING NO GLUES OR <br />ADHESIVES, TO SOLID, EXTRUDED THERMOPLASTIC CORE; FORMED INTO PROFILE FOR <br />INSTALLATION METHOD INDICATED. INCLUDE ATTACHMENT SYSTEM COMPONENTS AND <br />ACCESSORIES REQUIRED FOR WEATHERTIGHT SYSTEM. <br />2. FIRE -RETARDANT CORE: NONCOMBUSTIBLE, WITH THE FOLLOWING SURFACE -BURNING <br />CHARACTERISTICS AS DETERMINED BY TESTING IDENTICAL PRODUCTS PER ASTM E 84 <br />BY UL OR ANOTHER TESTING AND INSPECTING AGENCY ACCEPTABLE TO AUTHORITIES <br />HAVING JURISDICTION: <br />3. FLAME -SPREAD INDEX: 25 OR LESS. <br />4. SMOKE -DEVELOPED INDEX: 450 OR LESS. <br />5. BASIS -OF -DESIGN PRODUCT: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE <br />ALPOLIC, DIVISION OF MITSUBISHI CHEMICAL AMERICA, INC.; [ALPOLIC] [ALPOLIC/FR] OR <br />A COMPARABLE PRODUCT FROM ONE OF THE FOLLOWING: <br />a. ALCAN COMPOSITES USA INC.; [ALUCOBOND] <br />b. AMERICAN PRODUCTS, INC.: [API] <br />c. ALCOA INC.; REYNOBOND [PE] <br />6. ALUMINUM -FACED COMPOSITE WALL PANELS: FORMED WITH 0.020-INCH- (0.50-MM-) <br />THICK, COIL -COATED, ALUMINUM SHEET FACINGS. <br />a. PANEL THICKNESS: [0.157 INCH (4 MM)] - 20G STEEL INTERIOR APPLICATION / 18G STEEL <br />EXTERIOR APPLICATION <br />b. EXTERIOR FINISH: 2-COAT FLUOROPOLYMER (TIGER DRYLAC OR EQUAL) <br />c. COLOR: AS NOTED ON DRAWINGS. <br />d. ATTACHMENT SYSTEM COMPONENTS: FORMED FROM MATERIAL COMPATIBLE WITH <br />PANEL FACING. <br />I. ACCESSORIES <br />1. WALL PANEL ACCESSORIES: PROVIDE COMPONENTS REQUIRED FOR A COMPLETE <br />METAL -FACED COMPOSITE WALL PANEL ASSEMBLY INCLUDING TRIM, COPINGS, FASCIA, <br />MULLIONS, SILLS, CORNER UNITS, CLIPS, FLASHINGS, SEALANTS, GASKETS, FILLERS, <br />CLOSURE STRIPS, AND SIMILAR ITEMS. MATCH MATERIAL AND FINISH OF METAL -FACED <br />COMPOSITE WALL PANELS UNLESS OTHERWISE INDICATED. <br />2. FLASHING AND TRIM: FORMED FROM 0.018-INCH- (0.46-MM-) MINIMUM THICKNESS, <br />ZINC -COATED (GALVANIZED) STEEL SHEET OR ALUMINUM -ZINC ALLOY -COATED STEEL <br />SHEET PREPAINTED WITH COIL COATING. PROVIDE FLASHING AND TRIM AS REQUIRED <br />TO SEAL AGAINST WEATHER AND TO PROVIDE FINISHED APPEARANCE. LOCATIONS <br />INCLUDE, BUT ARE NOT LIMITED TO, BASES, DRIPS, SILLS, JAMBS, CORNERS, <br />ENDWALLS, FRAMED OPENINGS, RAKES, FASCIA, PARAPET CAPS, SOFFITS, REVEALS, <br />AND FILLERS. FINISH FLASHING AND TRIM WITH SAME FINISH SYSTEM AS ADJACENT <br />METAL -FACED COMPOSITE WALL PANELS. <br />J. FABRICATION <br />1. GENERAL: FABRICATE AND FINISH METAL -FACED COMPOSITE WALL PANELS AND <br />ACCESSORIES AT THE FACTORY TO GREATEST EXTENT POSSIBLE, BY <br />MANUFACTURER'S STANDARD PROCEDURES AND PROCESSES, AS NECESSARY TO <br />FULFILL INDICATED PERFORMANCE REQUIREMENTS DEMONSTRATED BY LABORATORY <br />TESTING. COMPLY WITH INDICATED PROFILES AND WITH DIMENSIONAL AND <br />STRUCTURAL REQUIREMENTS. <br />2. FABRICATE METAL -FACED COMPOSITE WALL OR BRAKE METAL PANELS IN A MANNER <br />THAT ELIMINATES CONDENSATION ON INTERIOR SIDE OF PANEL AND WITH JOINTS <br />BETWEEN PANELS DESIGNED TO FORM WEATHER TIGHT SEALS. <br />3. METAL -FACED COMPOSITE WALL PANELS: FACTORY FORM PANELS IN A CONTINUOUS <br />PROCESS WITH NO GLUES OR ADHESIVES BETWEEN DISSIMILAR MATERIALS. TRIM AND <br />SQUARE EDGES OF SHEETS WITH NO DISPLACEMENT OF FACE SHEETS OR <br />PROTRUSION OF CORE MATERIAL. <br />4. FORM PANEL LINES, BREAKS, AND ANGLES TO BE SHARP AND TRUE, WITH SURFACES <br />FREE FROM WARP AND BUCKLE. <br />5. FABRICATE PANELS WITH SHARPLY CUT EDGES, WITH NO DISPLACEMENT OF FACE <br />SHEETS OR PROTRUSION OF CORE MATERIAL. <br />6. FABRICATE PANELS WITH PANEL STIFFENERS, AS REQUIRED TO COMPLY WITH <br />DEFLECTION LIMITS, ATTACHED TO BACK OF PANELS WITH STRUCTURAL SILICONE <br />SEALANT OR BOND TAPE. <br />7. DIMENSIONAL TOLERANCES: <br />a. PANEL BOW: 0.5 PERCENT MAXIMUM OF PANEL LENGTH OR WIDTH. <br />b. SQUARENESS: 0.25 INCH (5 MM) MAXIMUM. <br />c. SHEET METAL ACCESSORIES: FABRICATE FLASHING AND TRIM TO COMPLY WITH <br />RECOMMENDATIONS IN SMACNA'S "ARCHITECTURAL SHEET METAL MANUAL" THAT APPLY <br />TO DESIGN, DIMENSIONS, METAL, AND OTHER CHARACTERISTICS OF ITEM INDICATED. <br />K. PREPARATION <br />1. MISCELLANEOUS FRAMING: INSTALL SUBGIRTS, BASE ANGLES, SILLS, FURRING, AND <br />OTHER MISCELLANEOUS WALL PANEL SUPPORT MEMBERS AND ANCHORAGE <br />ACCORDING TO ASTM C 754 AND METAL -FACED COMPOSITE WALL PANEL <br />MANUFACTURER'S WRITTEN INSTRUCTIONS. <br />L. METAL -FACED COMPOSITE WALL PANEL AND BRAKE METAL INSTALLATION <br />1. ATTACHMENT SYSTEM INSTALLATION, GENERAL: INSTALL ATTACHMENT SYSTEM <br />REQUIRED TO SUPPORT METAL -FACED COMPOSITE WALL PANELS AND TO PROVIDE A <br />COMPLETE WEATHERTIGHT WALL SYSTEM, INCLUDING SUBGIRTS, PERIMETER <br />EXTRUSIONS, TRACKS, DRAINAGE CHANNELS, PANEL CLIPS, AND ANCHOR CHANNELS. <br />2. INCLUDE ATTACHMENT TO SUPPORTS, PANEL -TO -PANEL JOINERY, <br />PANEL -TO -DISSIMILAR -MATERIAL JOINERY, AND PANEL -SYSTEM JOINT SEALS. <br />3. DO NOT BEGIN INSTALLATION UNTIL WEATHER BARRIER AND FLASHINGS THAT WILL BE <br />CONCEALED BY COMPOSITE PANELS ARE INSTALLED. <br />4. SEAL HORIZONTAL AND VERTICAL JOINTS BETWEEN ADJACENT PANELS WITH SEALANT <br />BACKING AND SEALANT. INSTALL SEALANT BACKING AND SEALANT ACCORDING TO <br />REQUIREMENTS SPECIFIED IN DIVISION 7 SECTION "JOINT SEALANTS." <br />5. ATTACH ROUTED -AND -RETURNED FLANGES OF WALL PANELS TO PERIMETER <br />EXTRUSIONS WITH MANUFACTURER'S STANDARD FASTENERS. ATTACH FLUSH WALL <br />PANELS TO PERIMETER EXTRUSIONS BY ENGAGING PANEL EDGES AND BY ATTACHING <br />WITH MANUFACTURER'S STANDARD STRUCTURAL SILICONE ADHESIVE. INSTALL WALL <br />PANELS TO ALLOW INDIVIDUAL PANELS TO "FREE FLOAT" AND BE INSTALLED AND <br />REMOVED WITHOUT DISTURBING ADJACENT PANELS. DO NOT APPLY SEALANTS TO <br />JOINTS UNLESS OTHERWISE INDICATED ON DRAWINGS. <br />M. ACCESSORY INSTALLATION <br />1. GENERAL: INSTALL ACCESSORIES WITH POSITIVE ANCHORAGE TO BUILDING AND <br />WEATHERTIGHT MOUNTING AND PROVIDE FOR THERMAL EXPANSION. COORDINATE <br />INSTALLATION WITH FLASHINGS AND OTHER COMPONENTS. <br />2. INSTALL COMPONENTS REQUIRED FOR A COMPLETE METAL -FACED COMPOSITE WALL <br />PANEL ASSEMBLY INCLUDING TRIM, COPINGS, CORNERS, SEAM COVERS, FLASHINGS, <br />SEALANTS, GASKETS, FILLERS, CLOSURE STRIPS, FRY REGLETS, AND SIMILAR ITEMS. <br />3. FLASHING AND TRIM: COMPLY WITH PERFORMANCE REQUIREMENTS, MANUFACTURER'S <br />WRITTEN INSTALLATION INSTRUCTIONS, AND SMACNA'S "ARCHITECTURAL SHEET <br />METAL MANUAL." PROVIDE CONCEALED FASTENERS WHERE POSSIBLE, AND SET UNITS <br />TRUE TO LINE AND LEVEL AS INDICATED. INSTALL WORK WITH LAPS, JOINTS, AND <br />SEAMS THAT WILL BE PERMANENTLY WATERTIGHT AND WEATHER RESISTANT. <br />N. ERECTION TOLERANCES <br />1. 1. INSTALLATION TOLERANCES: SHIM AND ALIGN METAL -FACED COMPOSITE WALL <br />PANEL UNITS WITHIN INSTALLED TOLERANCE <br />2. OF 1/4 INCH IN 20 FEET (6 MM IN 6 M), NONACCUMULATIVE, ON LEVEL, PLUMB, AND <br />LOCATION LINES AS INDICATED <br />3. AND WITHIN 1/8 INCH (3-MM) OFFSET OF ADJOINING FACES AND OF ALIGNMENT OF <br />MATCHING PROFILES. <br />0. CLEANING <br />1. REMOVE TEMPORARY PROTECTIVE COVERINGS AND STRIPPABLE FILMS, IF ANY, AS <br />METAL -FACED COMPOSITE WALL PANELS ARE INSTALLED UNLESS OTHERWISE <br />INDICATED IN MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS. ON <br />COMPLETION OF METAL -FACED COMPOSITE WALL PANEL INSTALLATION, CLEAN <br />FINISHED SURFACES AS RECOMMENDED BY PANEL MANUFACTURER. MAINTAIN IN A <br />CLEAN CONDITION DURING CONSTRUCTION. <br />079200 JOINT SEALANTS <br />A. QUALITY ASSURANCE: USE ONLY SKILLED INSTALLERS SPECIALLY TRAINED IN THE <br />TECHNIQUES OF SEALING, AND FAMILIAR WITH THE PUBLISHED RECOMMENDATIONS OF <br />THE MANUFACTURERS OF THE SEALANTS BEING USED. <br />B. SEALANTS: <br />TYPE S - NEUTRAL CURE SILICONE SEALANTS: <br />a. DOW CORNING, 790 SILICONE BUILDING SEALANT, OR 795 SILICONE STRUCTURAL GLAZING <br />AND WEATHERPROOFING SEALANT. <br />b. PECORA, 890 ARCHITECTURAL SILICONE SEALANT. <br />c. TREMCO "SPECTREM" 1 OR 3. <br />2. TYPE PT: ASTM C920, TYPE S, GRADE P, CLASS 25; TREMCO "THC 901", SONNEBORN <br />"SONOLASTIC SL 1", PECORA "UREXPAN NR-201", OR APPROVED. <br />3. TYPE PTNS: ASTM C920, TYPE M, GRADE NS, CLASS 25; PECORA "DYNATRED," TREMCO <br />"HPL," OR APPROVED; CUSTOM COLORS TO MATCH ARCHITECT'S SAMPLES. <br />T Mobile <br />12920 SE 38th STREET <br />BELLEVUE, WA 98006 <br />www.T-Mobile.com <br />COPYRIGHT NOTICE: <br />THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO <br />COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC 102 OF <br />THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED JANUARY 2003. THE PROTECTION <br />INCLUDES. WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND <br />COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN, UNDER SUCH <br />PROTECTIONUNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS <br />I MAY RESULT N CESSATION OF CONSTRUCTION, BUILDING SEIZURE, AND/OR <br />MONETARY LIABILITY. <br />ARCHITECT <br />rmUzioN <br />9096 EAST BAHIA DRIVE <br />SUITE 103 <br />SCOTTSDALE, AZ 85260 <br />DESIGN@FUZIONVE.COM <br />VWVW.FUZIONVE.COM <br />VENDOR PROJECT NO: 21.11.212680 <br />'OF FAO' <br />a!� �pA LOUTScl <br />' 100 4 ' <br />��R>ED <br />02/10/2022 <br />CONSULTING ENGINEER: <br />DS$CPJP ON 1 OAS gl <br />DATE: February 5, 2022 <br />SCALE: AS NOTED <br />DRAWN BY: LEO V. <br />SAP NUMBER: <br />4SIR <br />CORPORATE TENANT REBUILD <br />LDC <br />SHEET TITLE: <br />SPECIFICATIONS <br />SHEET NUMBER: <br />4 <br />3 <br />2 <br />A702 <br />