<br />SECTION - 061643 - GYPSUM SHEATHING
<br />A. SUMMARY:
<br />1. SHEATHING USED IN LIEU OF PLYWOOD IN NON-COMBUSTIBLE BUILDING
<br />CONSTRUCTION.
<br />B. MATERIALS
<br />1. SCREWS: GALVANIZED; SELF -DRILLING; SELF -DRILLING, BUGLE HEAD SCREWS;
<br />MINIMUM 1-1/4 INCH LONG.
<br />2, GYPSUM SHEATHING: ONE OF THE FOLLOWING:
<br />a. G-P GYPSUM CORPORATION "DENS -GLASS GOLD;" GLASS MAT FACED; ASTM C1177; 112
<br />INCH THICK
<br />b. USG FIBEROCK BRAND SHEATHING WITH AQUA-TOUGH(TM); 1/2 INCH THICK.
<br />C. INSTALLATION:
<br />1. INSTALL SQUARE EDGE BOARDS PARALLEL OR PERPENDICULAR TO FRAMING. INSTALL
<br />BOARDS PARALLEL TO FRAMING AT FIRE RATED WALLS, APPLY SHEATHING WITH
<br />JOINTS STAGGERED. ALL EDGES SHALL BE FIRMLY SUPPORTED.
<br />2. INSTALL SHEATHING WITH COATING TOWARDS EXTERIOR.
<br />3. SCREW TO FRAMING. SPACE FASTENERS 8 INCHES O.C. IN FIELD AND 4 INCHES O.C. AT
<br />ENDS ALONG EACH FRAMING MEMBER.
<br />4. DO NOT BRIDGE EXPANSION OR SEISMIC JOINTS.
<br />RIM
<br />., Y
<br />0$TP,iE:::1
<br />072100 THERMAL INSULATION
<br />A. SUMMARY: BUILDING INSULATION WHEN INDICATED ON THE DRAWINGS.
<br />B. MATERIALS
<br />1. UNFACED BATT AND BLANKET INSULATION: ASTM C665, TYPE I; PREFORMED UNFACED
<br />GLASS FIBER ROLL; FLAME SPREAD OF 25 OR LESS AND SMOKE DEVELOPED OF 50 OR
<br />LESS WHEN TESTED IN ACCORDANCE WITH ASTM E84;OVERSIZE WIDTHS FOR
<br />FRICTION -FIT BETWEEN METAL FRAMING.
<br />2. BOARD INSULATION: EXTRUDED POLYSTYRENE; DOW CHEMICAL COMPANY
<br />"STYROFOAM" OR OWENS CORNING "FOAMULAR 250."
<br />C. ACCESSORIES:
<br />1. SEPARATE VAPOR BARRIER FOR BATT INSULATION: FOIL SCRIM KRAFT FSK 25; FLAME
<br />SPREAD OF 25 OR LESS AND A SMOKE DEVELOPED OF 50 OR LESS WHEN TESTED IN
<br />ACCORDANCE WITH ASTM E84.
<br />2. TAPE: TO MATCH INSULATION FACING; 2 INCH WIDTH.
<br />3. ACOUSTIC INSULATION: SEE SECTION 098100.
<br />D. INSTALLATION:
<br />1. INSTALL INSULATION IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS
<br />AND AS INDICATED.
<br />2. TRIM INSULATION NEATLY TO FIT SPACES. INSTALL WITHOUT GAPS OR VOIDS.
<br />3. INSTALLATION OF THERMAL BATT INSULATION:
<br />a. INSTALL INSULATION WITH VAPOR BARRIER TOWARD WARM SIDE OF BUILDING SPACES.
<br />VAPOR BARRIER SHALL BE CONTINUOUS. TAPE SEAL TEARS OR CUTS IN VAPOR BARRIER.
<br />b. AT METAL STUD FRAMING, INSERT THE INSULATION EDGES TIGHTLY INTO THE STUD
<br />CHANNELS FOR A FRICTION FIT. WHERE INSULATION BUTTS THE BACKSIDE OF STUD
<br />CHANNELS, CONTINUOUSLY TAPE INSULATION FLANGES TO THE EXPOSED METAL STUD
<br />FLANGE.
<br />c. MECHANICAL FASTENING:
<br />4. AT LOCATIONS WHERE NO FRAMING IS PRESENT TO SUPPORT THE INSULATION,
<br />PROVIDE METAL IMPALING PINS AND RETAINERS TO HOLD THE INSULATION FIRMLY IN
<br />POSITION.
<br />5. MECHANICALLY OR ADHESIVELY BOND THE RETAINING PINS TO THE SUBSTRATE IN
<br />ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS.
<br />6. SPACE PINS AT MAXIMUM 24 INCHES ON CENTER ALONG THE EDGES AND WITHIN THE
<br />FIELD OF THE BLANKET. PLACE EDGE PINS WITHIN 6 INCHES FROM THE EDGE OF THE
<br />BATT.
<br />a. PACK BATT INSULATION IN SHIM SPACES AT PERIMETER OF WINDOW ASSEMBLY TO
<br />MAINTAIN CONTINUITY OF THERMAL BARRIER.
<br />7. SEPARATE VAPOR BARRIER INSTALLATION:
<br />a. INSTALL SEPARATE VAPOR BARRIER OVER UNFACED INSULATION.
<br />b. INSTALL VAPOR BARRIER TOWARD WARM SIDE OF BUILDING SPACES.
<br />c. VAPOR BARRIER SHALL BE CONTINUOUS.
<br />d. AT LOCATIONS WHERE INSULATION IS MECHANICALLY FASTENED BY IMPALING PINS,
<br />PLACE VAPOR RETARDER OVER IMPALING PINS AND HOLD IN POSITION WITH ADDITIONAL
<br />RETAINERS. THE INSTALLATION SHALL PRESENT A TIGHT, CONTINUOUS, AND WRINKLE
<br />FREE APPEARANCE.
<br />e. AT LIGHT GA SUPPORT FRAMING, SECURE TO STUDS WITH DOUBLE STICK TAPE OR
<br />SPRAY ADHESIVE.
<br />f. LAP JOINTS IN VAPOR BARRIER 2 INCHES, EXCEPT PROVIDE TAPE SEALED JOINTS AT
<br />LOCATIONS WHERE VAPOR BARRIER WILL REMAIN EXPOSED IN THE FINISHED WORK.
<br />g. TAPE SEAL VAPOR BARRIER TO ADJACENT CONSTRUCTION AT PERIMETER EDGES.
<br />h. TAPE AND SEAL TEARS OR CUTS IN VAPOR BARRIER.
<br />A. "R" VALUE SCHEDULE:
<br />1. BATT INSULATION: PROVIDE MINIMUM 6 INCH INSULATION THICKNESS (R19) TO FILL
<br />STUD CAVITY OR GREATER TO MATCH EXISTING IN SIMILAR APPLICATIONS, OR AS
<br />INDICATED ON THE DRAWINGS.
<br />2. RIGID INSULATION: PROVIDE MINIMUM 2 INCH INSULATION THICKNESS (R10) OR TO
<br />MATCH EXISTING IN SIMILAR APPLICATIONS.
<br />APPLIED EXTERIOR FINISH SYSTEM DEFS 072401 DIRECT (DEFS)
<br />A. SUMMARY:
<br />1. WHERE CEMENT PLASTER IS INDICATED ON THE DRAWINGS OVER EXISTING CMU,
<br />PROVIDE DIRECT APPLIED EXTERIOR FINISH SYSTEM (DEFS) OVER EXISTING
<br />CONCRETE MASONRY UNITS AS SPECIFIED.
<br />B. APPLICATOR QUALIFICATIONS:
<br />1. MINIMUM OF 5 YEARS EXPERIENCE IN THE APPLICATION OF DEFS OF SIMILAR SCOPE
<br />TO THE WORK INDICATED.
<br />2. INSTALLER SHALL HAVE BEEN TRAINED BY THE PRODUCT MANUFACTURER PRIOR TO
<br />BIDDING, AND SHALL BE CURRENTLY APPROVED BY THE MANUFACTURER TO INSTALL
<br />WARRANTABLE DEFS SYSTEM AS SPECIFIED.
<br />C. PROTECTION: PROTECT ADJACENT MATERIALS AND THIS SYSTEM FROM DAMAGE DURING
<br />INSTALLATION, WHILE CURING OR WHEN UNATTENDED.
<br />D. APPROVED MANUFACTURERS:
<br />1. DRYVIT SYSTEMS INC.
<br />2. STO INDUSTRIES, INC.
<br />3. SENERGY, INC.
<br />E. MATERIALS:
<br />1. PROVIDE MANUFACTURER'S STANDARD MATERIALS AS RECOMMENDED FOR THE
<br />INSTALLATION.
<br />2. BASE COAT: MANUFACTURER'S STANDARD POLYMER MODIFIED CEMENTITIOUS BASE
<br />COAT; MAXIMUM 30% CEMENT; DRY FACTORY PRE -MIXED FORMULA, OR
<br />PRE -MEASURED PACKAGED MATERIALS FOR CONSISTENT SITE MIXING.
<br />3. FINISH COAT: MANUFACTURER'S STANDARD; 100% ACRYLIC; CUSTOM INTEGRAL COLOR
<br />AS SELECTED BY THE ARCHITECT; LISTED BY UNDERWRITER'S LABORATORIES, INC. AS
<br />HAVING A FLAME SPREAD OF 25 OR LESS.
<br />4. REINFORCING MESH: MANUFACTURER'S STANDARD ALKALINE RESISTANT OPEN WEAVE
<br />GLASS FIBER MESH; STANDARD DUTY AND HEAVY DUTY.
<br />5. SUBSTRATE MESH TAPE: ALKALINE RESISTANT OPEN WEAVE GLASS FIBER MESH
<br />SURFACED ON ONE SIDE WITH PRESSURE SENSITIVE ADHESIVE; TYPE AS
<br />RECOMMENDED BY SYSTEM MANUFACTURER.
<br />6. DEFS TRIM:
<br />a. PRODUCTS OF VINYL CORPORATION (800-648-4695) ARE LISTED AS A STANDARD OF
<br />APPROVAL. SIMILAR AND EQUAL PRODUCTS BY PLASTIC COMPONENTS (800-327-7077) MAY
<br />BE USED. FABRICATE FROM EXTERIOR GRADE VINYL; PROVIDE MANUFACTURER'S
<br />STANDARD SPLICE PLATES AND CONNECTOR CLIPS FOR BUTT JOINT CONNECTIONS.
<br />b. CORNER BEAD: CB158E.
<br />F. INSTALLATION:
<br />1. PROTECT ADJACENT SURFACES FROM CONTACT WITH OVERSPRAY AND SPATTER OF
<br />PRIMERS, ADHESIVES, AND FINISH COATS.
<br />2. AT CONCRETE AND CMU SURFACES TO RECEIVE FINISH COAT ONLY, REMOVE ALL DIRT,
<br />DUST, FORM RELEASE AGENTS, EFFLORESCENCE, AND OTHER ELEMENTS WHICH
<br />WOULD IMPAIR BOND. ACID ETCH WITH MURIATIC ACID.
<br />3. INSTALL DEFS IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS.
<br />4. PROVIDE FINISH COAT ONLY OVER EXISTING CONCRETE BLOCK SURFACES AS
<br />INDICATED ON THE DRAWINGS.
<br />5. FINISH COATING SHALL BE APPLIED AS RECOMMENDED BY THE EXTERIOR INSULATION
<br />AND FINISH SYSTEM MANUFACTURER.
<br />Olvis"10, it r
<br />011
<br />6. TROWEL APPLY SKIM COAT OF MANUFACTURER'S RECOMMENDED FIBER REINFORCED
<br />POLYMER MODIFIED MORTAR TO OBTAIN SMOOTH AND FLAT SURFACES WITHIN A
<br />TOLERANCE OF 1/8 INCH IN 10 FEET, AND TO FILL SURFACE IMPERFECTIONS. USE
<br />BONDING AGENT AS NECESSARY FOR ADEQUATE BOND.
<br />7. APPLY COLOR MATCH PRIMER.
<br />8. PROVIDE FINISH COAT TO MATCH EXISTING.
<br />G. CLEAN-UP: REMOVE DIRT AND STAINS FROM DEFS SURFACES AND ADJACENT SURFACES
<br />WITHOUT DAMAGING FINISHES.
<br />07241 EXTERIOR INSULATION AND FINISH SYSTEMS - CLASS PB
<br />A. SUMMARY
<br />1. THIS SECTION INCLUDES CLASS PB EXTERIOR INSULATION AND FINISH SYSTEM (EIFS)
<br />[WITH DRAINAGE] APPLIED OVER SUBSTRATE AS INDICATED ON DRAWINGS.
<br />a. USE, MANUFACTURER, EXTENT, TEXTURE AND COLOR ARE SUBJECT TO T-MOBILE REVIEW
<br />AND APPROVAL
<br />2. ACCEPTABLE SUBSTRATES FOR OUTSULATION SYSTEMS.
<br />a. UNGLAZED BRICK, CEMENT PLASTER, CONCRETE, OR MASONRY.
<br />b. EXTERIOR GRADE GYPSUM SHEATHING MEETING ASTM C79 REQUIREMENTS FOR
<br />WATER-RESISTANT CORE OR TYPE X CORE AT THE TIME OF APPLICATION OF THE
<br />OUTSULATION SYSTEM.
<br />c. SILICONE TREATED GYPSUM CORE SHEATHING SURFACED WITH INORGANIC FIBERGLASS
<br />MATS MEETING ASTM C1177.
<br />d. EXTERIOR FIBER REINFORCED CEMENT AND CALCIUM SILICATE BOARDS.
<br />e. APA EXTERIOR OR EXPOSURE 1 RATED PLYWOOD, GRADE C-D OR BETTER, NOMINAL 13
<br />MM (1/2 IN.), MINIMUM PLY.
<br />f. APA EXPOSURE 1 RATED ORIENTED STRAND BOARD (OSB), NOMINAL 13 MM (1/2 IN.)
<br />g. GALVANIZED EXPANDED METAL LATH 1.4 OR 1.8 KG/M2 (2.6 OR 3.3 LBS/YD2) INSTALLED
<br />OVER A SOLID SUBSTRATE.
<br />h. DEFLECTION OF SUBSTRATE SYSTEMS SHALL NOT EXCEED U240.
<br />i. THE SLOPE OF INCLINED SURFACES SHALL NOT BE LESS THEN 6:12.
<br />j. THE LENGTH OF INCLINED SURFACES SHALL NOT EXCEED 305 MM (121N).
<br />B. PERFORMANCE REQUIREMENTS
<br />1. CLASS PB EIFS: COMPLY WITH PERFORMANCE CHARACTERISTICS IN EIMA'S "EIMA
<br />GUIDELINE SPECIFICATION FOR EXTERIOR INSULATION AND FINIS
<br />H SYSTEMS, CLASS
<br />FIB."
<br />a. STANDARD IMPACT RESISITANCE: 25-49 INCH -LB (2.8-5.6 J) FOR AREAS ABOVE T-0."
<br />b. HIGH IMPACT RESISTANCE: 90-150 INCH -LB (10.2 - 17 J) FOR AREAS BELOW T-0."
<br />c. POSITIVE AND NEGATIVE WIND -LOAD PERFORMANCE: CAPABILITY TO WITHSTAND WIND
<br />LOADS INDICATED WHEN TESTED PER ASTM E 330.
<br />2. DRAINAGE: 3 SAMPLES CAPABLE OF DRAINING WATER, AND HAVING AN AVERAGE
<br />MINIMUM TRUE DRAINAGE EFFICIENCY OF [90] PERCENT WHEN TESTED PER EIMA 200.2.
<br />3. WATER -/WEATHER -RESISTIVE -BARRIER COATING: COMPLY WITH ICBO-ES AC24.
<br />C. SUBMITTALS
<br />1. PRODUCT DATA: FOR EACH PRODUCT INDICATED.
<br />2. SHOP DRAWINGS: INCLUDE PLANS, ELEVATIONS, SECTIONS, DETAILS, PENETRATIONS,
<br />TERMINATIONS, FASTENERS, AND ATTACHMENTS TO OTHER WORK.
<br />3. SAMPLES: FOR EACH EIFS AND FOR EACH COLOR AND TEXTURE REQUIRED.
<br />4. FIELD QUALITY -CONTROL TEST REPORTS.
<br />5. PRODUCT [TEST REPORTS].
<br />6. MAINTENANCE DATA.
<br />A. QUALITY ASSURANCE
<br />1. INSTALLER QUALIFICATIONS: CERTIFIED IN WRITING BY EIFS MANUFACTURER TO
<br />INSTALL MANUFACTURER'S SYSTEM USING TRAINED WORKERS.
<br />2. SOURCE LIMITATIONS: OBTAIN EIFS THROUGH ONE SOURCE FROM A SINGLE EIFS
<br />MANUFACTURER AND FROM SOURCES APPROVED BY EIFS MANUFACTURER AS
<br />COMPATIBLE WITH SYSTEM COMPONENTS.
<br />3. FIRE -TEST -RESPONSE CHARACTERISTICS: WHERE INDICATED, PROVIDE EIFS AND
<br />SYSTEM COMPONENTS IDENTICAL TO THOSE OF EIFS AND SYSTEM COMPONENTS
<br />TESTED PER TEST METHOD INDICATED BELOW BY UL OR ANOTHER TESTING AND
<br />INSPECTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. IDENTIFY
<br />PRODUCTS WITH APPROPRIATE MARKINGS OF APPLICABLE TESTING AND INSPECTING
<br />AGENCY.
<br />a. FLAME SPREAD OF INSULATION BOARD AND FINISH COATS: 25 OR LESS WHEN TESTED
<br />INDIVIDUALLY PER ASTM E 84.
<br />b. SMOKE DEVELOPED OF INSULATION BOARD AND FINISH COATS; 450 OR LESS WHEN
<br />TESTED INDIVIDUALLY PER ASTM E 84.
<br />E. MANUFACTURERS
<br />1. AVAILABLE MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS,
<br />MANUFACTURERS OFFERING PRODUCTS THAT MAY BE INCORPORATED INTO THE
<br />WORK INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING:
<br />2. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE
<br />PRODUCTS BY ONE OF THE FOLLOWING:
<br />a. DRYVIT SYSTEMS, INC.
<br />b. SENERGY INC.; SKW-MBT CONSTRUCTION CHEMICALS.
<br />c. STO CORP.
<br />3. BASIS -OF -DESIGN PRODUCT: THE DESIGN FOR EIFS[ WITH DRAINAGE] IS BASED ON
<br />DRYVIT OUTSULATION SYSTEM REQUIREMENTS. SUBJECT TO COMPLIANCE WITH
<br />REQUIREMENTS, PROVIDE THE NAMED PRODUCT OR A COMPARABLE PRODUCT BY ONE
<br />OF THE FOLLOWING MANUFACTURERS LISTED ABOVE.
<br />F. MATERIALS
<br />1. COMPATIBILITY: PROVIDE SUBSTRATES, ADHESIVE, FASTENERS, BOARD INSULATION,
<br />REINFORCING MESHES, BASE- AND FINISH -COAT SYSTEMS, SEALANTS, AND
<br />ACCESSORIES THAT ARE COMPATIBLE WITH ONE ANOTHER AND APPROVED FOR USE
<br />BY EIFS MANUFACTURER FOR PROJECT.
<br />2. WATER -/WEATHER -RESISTIVE -BARRIER COATING: FORMULATION AND ACCESSORIES
<br />DESIGNED FOR INDICATED USE.
<br />3. PRIMER/SEALER: SUBSTRATE CONDITIONER DESIGNED TO SEAL SUBSTRATES FROM
<br />MOISTURE PENETRATION AND TO IMPROVE THE BOND BETWEEN SUBSTRATE OF TYPE
<br />INDICATED AND ADHESIVE USED FOR APPLICATION OF INSULATION,
<br />4. DRAINAGE MAT: DESIGNED TO DRAIN INCIDENTAL MOISTURE BY GRAVITY; EIFS
<br />MANUFACTURER'S STANDARD OR PRODUCT RECOMMENDED IN WRITING BY EIFS
<br />MANUFACTURER [WITH MANUFACTURER'S STANDARD CORROSION -RESISTANT
<br />MECHANICAL FASTENERS SUITABLE FOR INTENDED SUBSTRATE].
<br />]
<br />5. SPACERS: FURRING STRIPS; EIFS MANUFACTURER'S STANDARD OR PRODUCT
<br />RECOMMENDED IN WRITING BY EIFS MANUFACTURER [WITH MANUFACTURER'S
<br />STANDARD CORROSION -RESISTANT MECHANICAL FASTENERS SUITABLE FOR
<br />INTENDED SUBSTRATE].
<br />6, ADHESIVE FOR APPLICATION OF INSULATION: MFR'S STANDARD.
<br />7. MOLDED, RIGID CELLULAR POLYSTYRENE BOARD INSULATION: COMPLY WITH EIFS
<br />MANUFACTURER'S REQUIREMENTS, ASTM C 578 FOR TYPE I, AND EIMA'S "EIMA
<br />GUIDELINE SPECIFICATION FOR EXPANDED POLYSTYRENE (EPS) INSULATION BOARD."
<br />a. CHANNELED BOARD INSULATION: EIFS MANUFACTURER'S STANDARD
<br />FACTORY -FABRICATED PROFILE WITH LINEAR VERTICAL DRAINAGE CHANNELS, SLOTS, OR
<br />WAVES ON THE BACK SIDE OF BOARD.
<br />8. REINFORCING MESH: BALANCED, ALKALI -RESISTANT, OPEN -WEAVE GLASS -FIBER MESH
<br />TREATED FOR COMPATIBILITY WITH OTHER EIFS MATERIALS AND COMPLYING WITH
<br />EIMA 105.01 AND ASTM D 578.
<br />a. STANDARD -IMPACT REINFORCING MESH: NOT LESS THAN [4.0 OZ./SQ. YD. (136 G/SQ. M)]
<br />b. HIGH -IMPACT REINFORCING MESH: NOT LESS THAN [15 OZ./ SQ. YD.
<br />(509 G/SQ. M)] T-0" DOWN TO FF.
<br />c. DETAIL REINFORCING MESH: NOT LESS THAN [4.0 OZ./SQ. YD. (136 G/SQ. M)].
<br />d. CORNER REINFORCING MESH: NOT LESS THAN [7.2 OZ./SQ. YD. (244 G/SQ. M)].
<br />9. BASE -COAT MATERIALS: STANDARD MIXTURE.
<br />10. WATERPROOF ADHESIVE/BASE-COAT MATERIALS: WATERPROOF MIXTURE.
<br />11. PRIMER: FACTORY -MIXED ELASTOMERIC-POLYMER PRIMER FOR PREPARING
<br />BASE -COAT SURFACE FOR APPLICATION OF FINISH COAT.
<br />12. FINISH -COAT MATERIALS: [STANDARD ACRYLIC -BASED COATING WITH ENHANCED
<br />MILDEW RESISTANCE].COLORS, TEXTURES, AND PATTERNS: REFERENCE EXTERIOR
<br />FINISH SCHEDULE ON DRAWINGS.
<br />13. MECHANICAL FASTENERS: CORROSION -RESISTANT FASTENERS CONSISTING OF
<br />THERMAL CAP, STANDARD WASHER AND SHAFT ATTACHMENTS, AND FASTENER
<br />SUITABLE FOR SUBSTRATE.
<br />14. TRIM ACCESSORIES: MANUFACTURED FROM UV -STABILIZED PVC AND COMPLYING
<br />WITH ASTM D 1784 AND ASTM C 1063.
<br />A. INSTALLATION
<br />1. GENERAL: COMPLY WITH ASTM C 1397 AND EIFS MANUFACTURER'S WRITTEN
<br />INSTRUCTIONS FOR INSTALLATION OF EIFS AS APPLICABLE TO EACH TYPE OF
<br />SUBSTRATE INDICATED.
<br />2. INSULATION: [ADHESIVELY AND MECHANICALLY] ATTACH TO SUBSTRATE.
<br />3. EXPANSION JOINTS: INSTALL AT LOCATIONS INDICATED; WHERE REQUIRED BY EIFS
<br />MANUFACTURER; WHERE EXPANSION JOINTS ARE INDICATED IN SUBSTRATES BEHIND
<br />EIFS; WHERE EIFS ADJOIN DISSIMILAR SUBSTRATES, MATERIALS, AND CONSTRUCTION;
<br />AT FLOOR LINES IN MULTILEVEL WOOD -FRAMED CONSTRUCTION; AND WHERE WALL
<br />HEIGHT CHANGES.
<br />771
<br />- D I■
<br />4. BASE COAT: APPLY TO EXPOSED SURFACES OF INSULATION IN MINIMUM THICKNESS
<br />RECOMMENDED IN WRITING BY EIFS MANUFACTURER, BUT NOT LESS THAN [1/16-INCH
<br />(1.6-MM)] DRY -COAT THICKNESS.
<br />5. REINFORCING MESH: COMPLETELY EMBED MESH IN WET BASE COAT, APPLYING
<br />ADDITIONAL BASE -COAT MATERIAL IF NECESSARY, SO REINFORCING -MESH COLOR AND
<br />PATTERN ARE NOT VISIBLE.
<br />6. DOUBLE -LAYER REINFORCING MESH APPLICATION: WHERE INDICATED, APPLY SECOND
<br />BASE COAT AND SECOND LAYER OF [STANDARD] IMPACT REINFORCING MESH.
<br />7. DOUBLE BASE -COAT APPLICATION: WHERE INDICATED, APPLY IN SAME MANNER AND
<br />THICKNESS AS FIRST APPLICATION EXCEPT WITHOUT REINFORCING MESH.
<br />8, FINISH COAT: APPLY OVER DRY [PRIMER] AND [BASE COAT], MAINTAINING A WET EDGE
<br />AT ALL TIMES FOR UNIFORM APPEARANCE, IN THICKNESS REQUIRED BY EIFS
<br />MANUFACTURER TO PRODUCE A UNIFORM FINISH OF COLOR AND TEXTURE MATCHING
<br />APPROVED SAMPLE AND FREE OF COLD JOINTS, SHADOW LINES, AND TEXTURE
<br />VARIATIONS. (FINE SAND TEXTURED FINISH).
<br />H. FIELD QUALITY CONTROL
<br />1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER APPLICATION OF THE
<br />OUTSULATION MATERIALS.
<br />2. MANUFACTURER ASSUMES NO RESPONSIBILITY FOR ON -SITE INSPECTIONS OR
<br />APPLICATION OF ITS PRODUCTS.
<br />3. IF REQUIRED, THE CONTRACTOR SHALL CERTIFY IN WRITING THE QUALITY OF WORK
<br />PERFORMED RELATIVE TO THE SUBSTRATE SYSTEM,DETAILS, INSTALLATION
<br />PROCEDURES, WORKMANSHIP AND AS TO THE SPECIFIC PRODUCTS USED.
<br />4. IF REQUIRED, THE EPS SUPPLIER SHALL CERTIFY IN WRITING THA THE EPS MEETS
<br />MANUFACTURER'S SPECIFICATIONS.
<br />5. IF REQUIRED, THE SEALANT CONTRACTOR SHALL CERTIFY IN WRITING THAT THE
<br />SEALANT APPLICATION IS IN ACCORDANCE WITH THE SEALANT MANUFACTURER'S AND
<br />MANUFACTURER'S RECOMMENDATIONS.
<br />I. CLEANING
<br />1. ALL EXCESS OUTSULATION SYSTEM MATERIALS SHALL BE REMOVED FROM THE JOB
<br />SITE BY THE CONTRACTOR IN ACCORDANCE WITH CONTRACT PROVISIONS AND AS
<br />REQUIRED BY APPLICABLE LAW.
<br />2. ALL SURROUNDING AREAS, WHERE THE OUTSULATION SYSTEM HAS BEEN INSTALLED,
<br />SHALL BE LEFT FREE OF DEBRIS AND FOREIGN SUBSTANCES RESULTING FROM THE
<br />CONTRACTOR'S WORK.
<br />J. PROTECTION
<br />1. THE OUTSULATION SYSTEM SHALL BE PROTECTED FROM INCLEMENT WEATHER AND
<br />OTHER SOURCES OF DAMAGE UNTIL DRY AND PERMANENT PROTECTION IN THE FORM
<br />OF FLASHINGS, SEALANTS, ETC. ARE INSTALLED.
<br />SECTION 07415 - COMPOSITE WALL PANELS OR BRAKE METAL (IF NOTED ON DRAWINGS)
<br />A. PERFORMANCE REQUIREMENTS
<br />1. DELEGATED DESIGN: DESIGN METAL -FACED COMPOSITE WALL PANEL OR BRAKE
<br />METAL ASSEMBLY, INCLUDING COMPREHENSIVE ENGINEERING ANALYSIS BY A
<br />QUALIFIED PROFESSIONAL ENGINEER.STRUCTURAL PERFORMANCE: PROVIDE
<br />METAL -FACED COMPOSITE WALL PANEL ASSEMBLIES CAPABLE OF WITHSTANDING THE
<br />EFFECTS OF THE FOLLOWING LOADS AND STRESSES WITHIN LIMITS AND UNDER
<br />CONDITIONS INDICATED, BASED ON TESTING ACCORDING TO ASTM E 330:
<br />2. WIND LOADS: DETERMINE LOADS BASED ON THE FOLLOWING MINIMUM DESIGN WIND
<br />PRESSURES: 20 LBF/SQ. FT. UNIFORM PRESSURE OF ACTING (957 PA) INWARD OR
<br />OUTWARD.
<br />3. DEFLECTION LIMITS: METAL -FACED COMPOSITE WALL PANEL ASSEMBLIES SHALL
<br />WITHSTAND WIND LOADS WITH HORIZONTAL DEFLECTIONS NO GREATER THAN [1/175
<br />OF THE SPAN AT THE PERIMETER AND 1/60 OF THE SPAN ANYWHERE IN THE PANEL] <
<br />OF THE SPAN.
<br />B. PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED.
<br />1. SHOP DRAWINGS: SHOW FABRICATION AND INSTALLATION LAYOUTS OF METAL -FACED
<br />COMPOSITE WALL PANELS; DETAILS OF EDGE CONDITIONS, JOINTS, PANEL PROFILES,
<br />CORNERS, ANCHORAGES, ATTACHMENT SYSTEM, TRIM, FLASHINGS, CLOSURES, AND
<br />ACCESSORIES; AND SPECIAL DETAILS. DISTINGUISH AMONG FACTORY-, SHOP-, AND
<br />FIELD -ASSEMBLED WORK. SAMPLES: FOR EACH TYPE OF EXPOSED FINISH REQUIRED.
<br />2. DELEGATED -DESIGN SUBMITTAL: FOR METAL -FACED COMPOSITE WALL PANEL
<br />ASSEMBLY INDICATED TO COMPLY WITH PERFORMANCE REQUIREMENTS AND DESIGN
<br />CRITERIA, INCLUDING ANALYSIS DATA AND CALCULATIONS SIGNED AND SEALED BY THE
<br />QUALIFIED PROFESSIONAL ENGINEER RESPONSIBLE FOR THEIR PREPARATION.
<br />COORDINATION DRAWINGS: EXTERIOR ELEVATIONS, DRAWN TO SCALE, ON WHICH THE
<br />FOLLOWING ITEMS ARE SHOWN AND COORDINATED WITH EACH OTHER.
<br />C. QUALITY ASSURANCE
<br />1. MANUFACTURER QUALIFICATIONS: MINIMUM 5 YEARS CONTINUOUS EXPERIENCE
<br />MANUFACTURING THE PANEL MATERIAL SPECIFIED, WITH NO OUTSOURCED
<br />PRODUCTION PROCESSES.ISO 9001 CERTIFIED.
<br />2. FABRICATOR QUALIFICATIONS: MINIMUM 3 YEARS EXPERIENCE ON PROJECTS OF
<br />COMPARABLE SCOPE AND SCALE, AND CAPABLE OF PROVIDING FIELD SERVICE
<br />REPRESENTATION DURING CONSTRUCTION. INSTALLER QUALIFICATIONS: MINIMUM 3
<br />YEARS EXPERIENCE ON PROJECTS OF COMPARABLE SCOPE AND SCALE, AND CAPABLE
<br />OF PROVIDING FIELD SERVICE REPRESENTATION DURING CONSTRUCTION.
<br />3. FIRE -RESISTANCE RATINGS: WHERE INDICATED, PR VIDE METAL -FACED COMP
<br />OSITE
<br />WALL PANELS IDENTICAL TO THOSE OF ASSEMBLIES TESTED FOR FIRE RESISTANCE
<br />PER ASTM E 119 BY A QUALIFIED TESTING AGENCY. IDENTIFY PRODUCTS WITH
<br />APPROPRIATE MARKINGS OF APPLICABLE TESTING AGENCY.
<br />D. WARRANTY
<br />1. SPECIAL WARRANTY: MANUFACTURER'S STANDARD FORM IN WHICH MANUFACTURER
<br />AGREES TO REPAIR OR REPLACE COMPONENTS OF METAL -FACED COMPOSITE WALL
<br />PANEL ASSEMBLIES THAT FAIL IN MATERIALS OR WORKMANSHIP WITHIN SPECIFIED
<br />WARRANTY PERIOD.
<br />2. WARRANTY PERIOD: [TEN] YEARS FROM DATE OF SUBSTANTIAL COMPLETION.
<br />3. SPECIAL WARRANTY ON PANEL FINISHES: MANUFACTURER'S STANDARD FORM IN
<br />WHICH MANUFACTURER AGREES TO REPAIR FINISH OR REPLACE METAL -FACED
<br />COMPOSITE WALL PANELS THAT SHOW EVIDENCE OF DETERIORATION OF FACTORY
<br />-APPLIED FINISHES WITHIN SPECIFIED WARRANTY PERIOD.
<br />4. FINISH WARRANTY PERIOD: [20] > YEARS FROM DATE OF SUBSTANTIAL COMPLETION.
<br />E. PRODUCTS
<br />1. PANEL MATERIALS.
<br />a. ALUMINUM SHEET: COIL -COATED SHEET, ASTM B 209), ALLOY AS STANDARD WITH
<br />MANUFACTURER, WITH TEMPER AS REQUIRED TO SUIT FORMING OPERATIONS AND
<br />STRUCTURAL PERFORMANCE REQUIRED.
<br />2. SURFACE: SMOOTH, FLAT FINISH.
<br />3. EXPOSED COIL -COATED FINISHES:
<br />a. TWO -COAT FEVE FLUOROPOLYMER: AAMA 620.
<br />b. TWO -COAT PVDF FLUOROPOLYMER: AAMA 620.
<br />4. EXPOSED ANODIZED FINISHES:
<br />a. COLOR ANODIC FINISH: AAMA 611, [AA-M12C22A42/A44, CLASS I, 0.018 MM]
<br />[AA-M12C22A32/A34, CLASS 11, 0.010 MM] OR THICKER.
<br />b. CONCEALED FINISH: APPLY PRETREATMENT AND MANUFACTURER'S STANDARD WHITE OR
<br />LIGHT-COLORED ACRYLIC OR POLYESTER BACKER FINISH, CONSISTING OF PRIME COAT
<br />AND WASH COAT 0.5 MIL WITH A MINIMUM TOTAL DRY FILM THICKNESS OF. (0.013 MM)
<br />5. PANEL SEALANTS: ASTM C 920.
<br />F. MISCELLANEOUS METAL FRAMING
<br />1. MISCELLANEOUS METAL FRAMING, GENERAL: ASTM C 645, COLD -FORMED
<br />METALLIC -COATED STEEL SHEET, [ASTM A 653 /A 653M, G40 (Z120) HOT -DIP
<br />GALVANIZED] OR COATING WITH EQUIVALENT CORROSION RESISTANCE UNLESS
<br />OTHERWISE INDICATED.
<br />2. SUBGIRTS: MANUFACTURER'S STANDARD C- OR Z-SHAPED SECTIONS 0.064-INCH
<br />(1.63-MM) NOMINAL THICKNESS.
<br />3. ZEE CLIPS: 0.079-INCH (2.01-MM) NOMINAL THICKNESS.
<br />4. BASE OR SILL [ANGLES] [CHANNELS]: 0.079-INCH (2.01-MM) NOMINAL THICKNESS.
<br />5. HAT -SHAPED, RIGID FURRING CHANNELS: NOMINAL THICKNESS: [AS INDICATED] [AS
<br />REQUIRED TO MEET PERFORMANCE REQUIREMENTS] [0.025 INCH (0.64MM)] > DEPTH:
<br />[AS INDICATED] [1-1/2 INCHES (38 MM)]
<br />6. COLD -ROLLED FURRING CHANNELS: MINIMUM 1/2-INCH- (13-MM-) WIDE FLANGE.
<br />NOMINAL THICKNESS: [AS INDICATED] [AS REQUIRED TO MEET PERFORMANCE
<br />REQUIREMENTS] [0.064 INCH (1.63MM)]< DEPTH: [AS INDICATED] [ 3/4 INCH (19 MM)] <
<br />7, FURRING BRACKETS: ADJUSTABLE, CORRUGATED -EDGE TYPE OF STEEL SHEET WITH
<br />NOMINAL THICKNESS OF 0.040 INCH (1.02. MM)
<br />8. TIE WIRE: ASTM A 641/A 641M, CLASS 1 ZINC COATING, SOFT TEMPER,
<br />0.062-INCH-(1.57-MM-) DIAMETER WIRE, OR DOUBLE STRAND OF 0.048-INCH- (1.22-MM-)
<br />DIAMETER WIRE.
<br />G. MISCELLANEOUS MATERIALS
<br />1. ALUMINUM EXTRUSIONS: ASTM B 221
<br />2. FASTENERS: SELF -TAPPING SCREWS, BOLTS, NUTS, SELF-LOCKING RIVETS AND BOLTS,
<br />END -WELDED STUDS, AND OTHER SUITABLE FASTENERS DESIGNED TO WITHSTAND
<br />DESIGN LOADS. PROVIDE EXPOSED FASTENERS WITH HEADS MATCHING COLOR OF
<br />METAL -FACED COMPOSITE WALL PANELS BY MEANS OF PLASTIC CAPS OR
<br />FACTORY -APPLIED COATING. PROVIDE EPDM, PVC, OR NEOPRENE SEALING WASHERS.
<br />NO VISIBLE MECHANICAL FASTENERS.
<br />tt
<br />H. METAL -FACED COMPOSITE WALL PANELS OR BRAKE METAL
<br />1. GENERAL: PROVIDE FACTORY -FORMED AND -ASSEMBLED, METAL -FACED COMPOSITE
<br />WALL PANELS FABRICATED FROM TWO METAL FACINGS BONDED, USING NO GLUES OR
<br />ADHESIVES, TO SOLID, EXTRUDED THERMOPLASTIC CORE; FORMED INTO PROFILE FOR
<br />INSTALLATION METHOD INDICATED. INCLUDE ATTACHMENT SYSTEM COMPONENTS AND
<br />ACCESSORIES REQUIRED FOR WEATHERTIGHT SYSTEM.
<br />2. FIRE -RETARDANT CORE: NONCOMBUSTIBLE, WITH THE FOLLOWING SURFACE -BURNING
<br />CHARACTERISTICS AS DETERMINED BY TESTING IDENTICAL PRODUCTS PER ASTM E 84
<br />BY UL OR ANOTHER TESTING AND INSPECTING AGENCY ACCEPTABLE TO AUTHORITIES
<br />HAVING JURISDICTION:
<br />3. FLAME -SPREAD INDEX: 25 OR LESS.
<br />4. SMOKE -DEVELOPED INDEX: 450 OR LESS.
<br />5. BASIS -OF -DESIGN PRODUCT: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE
<br />ALPOLIC, DIVISION OF MITSUBISHI CHEMICAL AMERICA, INC.; [ALPOLIC] [ALPOLIC/FR] OR
<br />A COMPARABLE PRODUCT FROM ONE OF THE FOLLOWING:
<br />a. ALCAN COMPOSITES USA INC.; [ALUCOBOND]
<br />b. AMERICAN PRODUCTS, INC.: [API]
<br />c. ALCOA INC.; REYNOBOND [PE]
<br />6. ALUMINUM -FACED COMPOSITE WALL PANELS: FORMED WITH 0.020-INCH- (0.50-MM-)
<br />THICK, COIL -COATED, ALUMINUM SHEET FACINGS.
<br />a. PANEL THICKNESS: [0.157 INCH (4 MM)] - 20G STEEL INTERIOR APPLICATION / 18G STEEL
<br />EXTERIOR APPLICATION
<br />b. EXTERIOR FINISH: 2-COAT FLUOROPOLYMER (TIGER DRYLAC OR EQUAL)
<br />c. COLOR: AS NOTED ON DRAWINGS.
<br />d. ATTACHMENT SYSTEM COMPONENTS: FORMED FROM MATERIAL COMPATIBLE WITH
<br />PANEL FACING.
<br />I. ACCESSORIES
<br />1. WALL PANEL ACCESSORIES: PROVIDE COMPONENTS REQUIRED FOR A COMPLETE
<br />METAL -FACED COMPOSITE WALL PANEL ASSEMBLY INCLUDING TRIM, COPINGS, FASCIA,
<br />MULLIONS, SILLS, CORNER UNITS, CLIPS, FLASHINGS, SEALANTS, GASKETS, FILLERS,
<br />CLOSURE STRIPS, AND SIMILAR ITEMS. MATCH MATERIAL AND FINISH OF METAL -FACED
<br />COMPOSITE WALL PANELS UNLESS OTHERWISE INDICATED.
<br />2. FLASHING AND TRIM: FORMED FROM 0.018-INCH- (0.46-MM-) MINIMUM THICKNESS,
<br />ZINC -COATED (GALVANIZED) STEEL SHEET OR ALUMINUM -ZINC ALLOY -COATED STEEL
<br />SHEET PREPAINTED WITH COIL COATING. PROVIDE FLASHING AND TRIM AS REQUIRED
<br />TO SEAL AGAINST WEATHER AND TO PROVIDE FINISHED APPEARANCE. LOCATIONS
<br />INCLUDE, BUT ARE NOT LIMITED TO, BASES, DRIPS, SILLS, JAMBS, CORNERS,
<br />ENDWALLS, FRAMED OPENINGS, RAKES, FASCIA, PARAPET CAPS, SOFFITS, REVEALS,
<br />AND FILLERS. FINISH FLASHING AND TRIM WITH SAME FINISH SYSTEM AS ADJACENT
<br />METAL -FACED COMPOSITE WALL PANELS.
<br />J. FABRICATION
<br />1. GENERAL: FABRICATE AND FINISH METAL -FACED COMPOSITE WALL PANELS AND
<br />ACCESSORIES AT THE FACTORY TO GREATEST EXTENT POSSIBLE, BY
<br />MANUFACTURER'S STANDARD PROCEDURES AND PROCESSES, AS NECESSARY TO
<br />FULFILL INDICATED PERFORMANCE REQUIREMENTS DEMONSTRATED BY LABORATORY
<br />TESTING. COMPLY WITH INDICATED PROFILES AND WITH DIMENSIONAL AND
<br />STRUCTURAL REQUIREMENTS.
<br />2. FABRICATE METAL -FACED COMPOSITE WALL OR BRAKE METAL PANELS IN A MANNER
<br />THAT ELIMINATES CONDENSATION ON INTERIOR SIDE OF PANEL AND WITH JOINTS
<br />BETWEEN PANELS DESIGNED TO FORM WEATHER TIGHT SEALS.
<br />3. METAL -FACED COMPOSITE WALL PANELS: FACTORY FORM PANELS IN A CONTINUOUS
<br />PROCESS WITH NO GLUES OR ADHESIVES BETWEEN DISSIMILAR MATERIALS. TRIM AND
<br />SQUARE EDGES OF SHEETS WITH NO DISPLACEMENT OF FACE SHEETS OR
<br />PROTRUSION OF CORE MATERIAL.
<br />4. FORM PANEL LINES, BREAKS, AND ANGLES TO BE SHARP AND TRUE, WITH SURFACES
<br />FREE FROM WARP AND BUCKLE.
<br />5. FABRICATE PANELS WITH SHARPLY CUT EDGES, WITH NO DISPLACEMENT OF FACE
<br />SHEETS OR PROTRUSION OF CORE MATERIAL.
<br />6. FABRICATE PANELS WITH PANEL STIFFENERS, AS REQUIRED TO COMPLY WITH
<br />DEFLECTION LIMITS, ATTACHED TO BACK OF PANELS WITH STRUCTURAL SILICONE
<br />SEALANT OR BOND TAPE.
<br />7. DIMENSIONAL TOLERANCES:
<br />a. PANEL BOW: 0.5 PERCENT MAXIMUM OF PANEL LENGTH OR WIDTH.
<br />b. SQUARENESS: 0.25 INCH (5 MM) MAXIMUM.
<br />c. SHEET METAL ACCESSORIES: FABRICATE FLASHING AND TRIM TO COMPLY WITH
<br />RECOMMENDATIONS IN SMACNA'S "ARCHITECTURAL SHEET METAL MANUAL" THAT APPLY
<br />TO DESIGN, DIMENSIONS, METAL, AND OTHER CHARACTERISTICS OF ITEM INDICATED.
<br />K. PREPARATION
<br />1. MISCELLANEOUS FRAMING: INSTALL SUBGIRTS, BASE ANGLES, SILLS, FURRING, AND
<br />OTHER MISCELLANEOUS WALL PANEL SUPPORT MEMBERS AND ANCHORAGE
<br />ACCORDING TO ASTM C 754 AND METAL -FACED COMPOSITE WALL PANEL
<br />MANUFACTURER'S WRITTEN INSTRUCTIONS.
<br />L. METAL -FACED COMPOSITE WALL PANEL AND BRAKE METAL INSTALLATION
<br />1. ATTACHMENT SYSTEM INSTALLATION, GENERAL: INSTALL ATTACHMENT SYSTEM
<br />REQUIRED TO SUPPORT METAL -FACED COMPOSITE WALL PANELS AND TO PROVIDE A
<br />COMPLETE WEATHERTIGHT WALL SYSTEM, INCLUDING SUBGIRTS, PERIMETER
<br />EXTRUSIONS, TRACKS, DRAINAGE CHANNELS, PANEL CLIPS, AND ANCHOR CHANNELS.
<br />2. INCLUDE ATTACHMENT TO SUPPORTS, PANEL -TO -PANEL JOINERY,
<br />PANEL -TO -DISSIMILAR -MATERIAL JOINERY, AND PANEL -SYSTEM JOINT SEALS.
<br />3. DO NOT BEGIN INSTALLATION UNTIL WEATHER BARRIER AND FLASHINGS THAT WILL BE
<br />CONCEALED BY COMPOSITE PANELS ARE INSTALLED.
<br />4. SEAL HORIZONTAL AND VERTICAL JOINTS BETWEEN ADJACENT PANELS WITH SEALANT
<br />BACKING AND SEALANT. INSTALL SEALANT BACKING AND SEALANT ACCORDING TO
<br />REQUIREMENTS SPECIFIED IN DIVISION 7 SECTION "JOINT SEALANTS."
<br />5. ATTACH ROUTED -AND -RETURNED FLANGES OF WALL PANELS TO PERIMETER
<br />EXTRUSIONS WITH MANUFACTURER'S STANDARD FASTENERS. ATTACH FLUSH WALL
<br />PANELS TO PERIMETER EXTRUSIONS BY ENGAGING PANEL EDGES AND BY ATTACHING
<br />WITH MANUFACTURER'S STANDARD STRUCTURAL SILICONE ADHESIVE. INSTALL WALL
<br />PANELS TO ALLOW INDIVIDUAL PANELS TO "FREE FLOAT" AND BE INSTALLED AND
<br />REMOVED WITHOUT DISTURBING ADJACENT PANELS. DO NOT APPLY SEALANTS TO
<br />JOINTS UNLESS OTHERWISE INDICATED ON DRAWINGS.
<br />M. ACCESSORY INSTALLATION
<br />1. GENERAL: INSTALL ACCESSORIES WITH POSITIVE ANCHORAGE TO BUILDING AND
<br />WEATHERTIGHT MOUNTING AND PROVIDE FOR THERMAL EXPANSION. COORDINATE
<br />INSTALLATION WITH FLASHINGS AND OTHER COMPONENTS.
<br />2. INSTALL COMPONENTS REQUIRED FOR A COMPLETE METAL -FACED COMPOSITE WALL
<br />PANEL ASSEMBLY INCLUDING TRIM, COPINGS, CORNERS, SEAM COVERS, FLASHINGS,
<br />SEALANTS, GASKETS, FILLERS, CLOSURE STRIPS, FRY REGLETS, AND SIMILAR ITEMS.
<br />3. FLASHING AND TRIM: COMPLY WITH PERFORMANCE REQUIREMENTS, MANUFACTURER'S
<br />WRITTEN INSTALLATION INSTRUCTIONS, AND SMACNA'S "ARCHITECTURAL SHEET
<br />METAL MANUAL." PROVIDE CONCEALED FASTENERS WHERE POSSIBLE, AND SET UNITS
<br />TRUE TO LINE AND LEVEL AS INDICATED. INSTALL WORK WITH LAPS, JOINTS, AND
<br />SEAMS THAT WILL BE PERMANENTLY WATERTIGHT AND WEATHER RESISTANT.
<br />N. ERECTION TOLERANCES
<br />1. 1. INSTALLATION TOLERANCES: SHIM AND ALIGN METAL -FACED COMPOSITE WALL
<br />PANEL UNITS WITHIN INSTALLED TOLERANCE
<br />2. OF 1/4 INCH IN 20 FEET (6 MM IN 6 M), NONACCUMULATIVE, ON LEVEL, PLUMB, AND
<br />LOCATION LINES AS INDICATED
<br />3. AND WITHIN 1/8 INCH (3-MM) OFFSET OF ADJOINING FACES AND OF ALIGNMENT OF
<br />MATCHING PROFILES.
<br />0. CLEANING
<br />1. REMOVE TEMPORARY PROTECTIVE COVERINGS AND STRIPPABLE FILMS, IF ANY, AS
<br />METAL -FACED COMPOSITE WALL PANELS ARE INSTALLED UNLESS OTHERWISE
<br />INDICATED IN MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS. ON
<br />COMPLETION OF METAL -FACED COMPOSITE WALL PANEL INSTALLATION, CLEAN
<br />FINISHED SURFACES AS RECOMMENDED BY PANEL MANUFACTURER. MAINTAIN IN A
<br />CLEAN CONDITION DURING CONSTRUCTION.
<br />079200 JOINT SEALANTS
<br />A. QUALITY ASSURANCE: USE ONLY SKILLED INSTALLERS SPECIALLY TRAINED IN THE
<br />TECHNIQUES OF SEALING, AND FAMILIAR WITH THE PUBLISHED RECOMMENDATIONS OF
<br />THE MANUFACTURERS OF THE SEALANTS BEING USED.
<br />B. SEALANTS:
<br />TYPE S - NEUTRAL CURE SILICONE SEALANTS:
<br />a. DOW CORNING, 790 SILICONE BUILDING SEALANT, OR 795 SILICONE STRUCTURAL GLAZING
<br />AND WEATHERPROOFING SEALANT.
<br />b. PECORA, 890 ARCHITECTURAL SILICONE SEALANT.
<br />c. TREMCO "SPECTREM" 1 OR 3.
<br />2. TYPE PT: ASTM C920, TYPE S, GRADE P, CLASS 25; TREMCO "THC 901", SONNEBORN
<br />"SONOLASTIC SL 1", PECORA "UREXPAN NR-201", OR APPROVED.
<br />3. TYPE PTNS: ASTM C920, TYPE M, GRADE NS, CLASS 25; PECORA "DYNATRED," TREMCO
<br />"HPL," OR APPROVED; CUSTOM COLORS TO MATCH ARCHITECT'S SAMPLES.
<br />T Mobile
<br />12920 SE 38th STREET
<br />BELLEVUE, WA 98006
<br />www.T-Mobile.com
<br />COPYRIGHT NOTICE:
<br />THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO
<br />COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC 102 OF
<br />THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED JANUARY 2003. THE PROTECTION
<br />INCLUDES. WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND
<br />COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN, UNDER SUCH
<br />PROTECTIONUNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS
<br />I MAY RESULT N CESSATION OF CONSTRUCTION, BUILDING SEIZURE, AND/OR
<br />MONETARY LIABILITY.
<br />ARCHITECT
<br />rmUzioN
<br />9096 EAST BAHIA DRIVE
<br />SUITE 103
<br />SCOTTSDALE, AZ 85260
<br />DESIGN@FUZIONVE.COM
<br />VWVW.FUZIONVE.COM
<br />VENDOR PROJECT NO: 21.11.212680
<br />'OF FAO'
<br />a!� �pA LOUTScl
<br />' 100 4 '
<br />��R>ED
<br />02/10/2022
<br />CONSULTING ENGINEER:
<br />DS$CPJP ON 1 OAS gl
<br />DATE: February 5, 2022
<br />SCALE: AS NOTED
<br />DRAWN BY: LEO V.
<br />SAP NUMBER:
<br />4SIR
<br />CORPORATE TENANT REBUILD
<br />LDC
<br />SHEET TITLE:
<br />SPECIFICATIONS
<br />SHEET NUMBER:
<br />4
<br />3
<br />2
<br />A702
<br />
|