<br />DIVISION 7w
<br />THERMAL AL ANDMOISTIE , CUNT
<br />4. TYPE A: ASTM C834; TREMCO "ACRYLIC LATEX CAULK", PECORA "AC-20", SONNEBORN
<br />"SONOLAC" OR APPROVED.
<br />5. TYPE SM: MILDEW RESISTANT SILICONE SEALANT: USDA APPROVED; DOW CORNING 786
<br />BY DOW CHEMICAL, GE SANITARY SEALANT OR APPROVED; CLEAR.
<br />C. ACCESSORY MATERIALS:
<br />1. PRIMER: NON -STAINING TYPE, RECOMMENDED BY SEALANT MANUFACTURER TO SUIT
<br />APPLICATION.
<br />2. JOINT CLEANER: NON -CORROSIVE AND NON -STAINING TYPE, RECOMMENDED BY
<br />SEALANT MANUFACTURER; COMPATIBLE WITH JOINT FORMING MATERIALS.
<br />3. JOINT FILLER: CLOSED CELL POLYETHYLENE FOAM; ROUND PROFILE; THICKNESS: 130%%%
<br />OF JOINT WIDTH.
<br />4. BOND BREAKER: PRESSURE SENSITIVE TAPE RECOMMENDED BY SEALANT
<br />MANUFACTURER TO SUIT APPLICATION.
<br />5. COMPRESSIBLE FOAM SEALANT: PRECOMPRESSED PREFACED SELF-ADHESIVE OPEN
<br />CELL POLYURETHANE FOAM TAPE; "BACKERSEAL" BY EMSEAL JOINT SYSTEMS, LTD.,
<br />OR APPROVED.
<br />D. PREPARATION:
<br />1. CLEAN AND PREPARE JOINTS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
<br />REMOVE LOOSE MATERIALS AND OTHER FOREIGN MATTER WHICH MIGHT IMPAIR
<br />ADHESION OF SEALANT.
<br />2. APPLY MASKING TIGHTLY AROUND JOINTS TO PROTECT ADJACENT SURFACES FROM
<br />EXCESS SEALANT.
<br />3. PRIME AS REQUIRED FOR PROPER BOND TO SUBSTRATE MATERIALS.
<br />E. INSTALLATION:
<br />1. PERFORM WORK IN ACCORDANCE WITH ASTM C1193, UNLESS SPECIFIED OTHERWISE
<br />OR RECOMMENDED OTHERWISE BY THE SEALANT MANUFACTURER.
<br />2. SEALANT BEADS SHALL HAVE A SECTIONAL WIDTH TO DEPTH RATIO OF 2 TO 1, EXCEPT
<br />THAT SEALANT TYPE PT SHALL BE INSTALLED FULL DEPTH WITHOUT BACKING.
<br />3. INSTALL TYPE PTNS SEALANT FULL DEPTH IN TILE EXPANSION JOINTS WITH NO BACKER
<br />ROD.
<br />4. TOOL JOINTS CONCAVE, UNLESS INDICATED OTHERWISE. FINISH FREE OF AIR
<br />POCKETS, FOREIGN EMBEDDED MATTER, RIDGES, AND SAGS.
<br />5. PROTECT SEALANT IN JOINTS SUBJECT TO DIRT, MOISTURE, AND TRAFFIC DURING THE
<br />SEALANT CURING PROCESS. PROTECTION SHALL BE ABLE TO RESIST TRAFFIC WHILE
<br />REMAINING SECURELY IN POSITION.
<br />F. SCHEDULE:
<br />1. TYPE S: PROVIDE AT ALL EXTERIOR JOINTS UNLESS SPECIFIED OTHERWISE;
<br />STANDARD COLORS AS SELECTED BY ARCHITECT.
<br />2. TYPE PT: PROVIDE AT ALL EXTERIOR HORIZONTAL JOINTS SUBJECT TO TRAFFIC AND
<br />ABRASION; STANDARD COLORS AS SELECTED BY ARCHITECT.
<br />3. TYPE PTNS: PROVIDE AT ALL EXPANSION JOINTS IN TILE; CUSTOM COLORS TO MATCH
<br />GROUT SAMPLES SUBMITTED BY TILE INSTALLER.
<br />4. TYPE A: PROVIDE AT ALL INTERIOR JOINTS, UNLESS SPECIFIED OTHERWISE; STANDARD
<br />COLORS TO MATCH ADJACENT CONSTRUCTION.
<br />5. TYPE SM: PROVIDE AT JOINTS AROUND COUNTERTOPS IN BACH OF HOUSE (BOH) AND
<br />RESTROOMS.
<br />DIvISI N $ OPENINGS
<br />081113 HOLLOW METAL DOORS AND FRAMES
<br />A. SUMMARY:
<br />1. INTERIOR DOOR FRAMES TO BE NOTED ON DOOR SCHEDULE PROVIDE "TIMELY" (OR
<br />EQUAL) PRE -FINISHED DOOR FRAME SYSTEMS (METAL) FOR
<br />2. EXTERIOR DOORS AND FRAMES, WHEN INDICATED ON THE DRAWINGS.
<br />B. REGULATORY REQUIREMENTS:
<br />1. WHERE REQUIRED, INSTALLED FRAME AND DOOR ASSEMBLY SHALL CONFORM TO
<br />NFPA 80 FOR FIRE RATED CLASS INDICATED.
<br />2. WHERE DOORS ARE NOTED WITH AN HOURLY FIRE RESISTANCE RATING, PROVIDE
<br />DOOR AND FRAME ASSEMBLIES LABELED BY UNDERWRITER'S LABORATORY (UL), OR
<br />ANOTHER TESTING LABORATORY APPROVED BY THE LOCAL CODE AUTHORITIES, TO
<br />MEET THE HOURLY FIRE RATING NOTED. ASSEMBLIES SHALL MEET CODE
<br />REQUIREMENTS FOR POSITIVE PRESSURE WHEN REQUIRED.
<br />3. INCLUDE "S" LABEL ON FIRE RATED DOOR ASSEMBLIES LOCATED AT 1 HOUR RATED
<br />EXIT CORRIDORS.
<br />C. QUALITY ASSURANCE:
<br />1. CONFORM TO REQUIREMENTS OF ANSI A250.8.
<br />D. ACCEPTABLE MANUFACTURERS: MEMBERS OF THE STEEL DOOR INSTITUTE AND OF THE
<br />NATIONAL ASSOCIATION OF ARCHITECTURAL METAL MANUFACTURERS, SUBJECT TO
<br />COMPLIANCE WITH SPECIFIED REQUIREMENTS.
<br />E. MATERIALS: STEEL SHEET, COLD ROLLED ASTM A366, OR HOT ROLLED PICKLED AND OILED
<br />SHEET CONFORMING TO ASTM A 569, MINIMUM 30% RECYCLED CONTENT.
<br />F. INTERIOR DOOR CONSTRUCTION:
<br />1. ANSI A250.8; SEAMLESS; MINIMUM 18 GA FACE SHEETS, 16 GA AT INVENTORY ROOM.
<br />2. CORE: VERTICAL STEEL STIFFENERS WITH SOUND DEADENING FILL BETWEEN
<br />STIFFENERS, OR RESIN IMPREGNATED KRAFT PAPER HONEY COMB CORE.
<br />3. PROVIDE CONTINUOUSLY WELDED SEAMLESS EDGES. NO PLASTIC FILLERS WILL BE
<br />ACCEPTED.
<br />G. EXTERIOR DOOR CONSTRUCTION:
<br />1. ANSI A250.8; SEAMLESS; MINIMUM 16 GA FACE SHEETS.
<br />2. CORE: POLYSTYRENE OR POLYURETHANE FOAM CORE.
<br />3. SPECIAL CONSTRUCTION REQUIREMENTS:
<br />a. PROVIDE CONTINUOUSLY WELDED SEAMLESS EDGES. NO PLASTIC FILLERS WILL BE
<br />ACCEPTED.
<br />b. CLOSE TOP EDGES OF EXTERIOR DOORS FLUSH WITH STEEL FILLER CAP; SEAL JOINTS
<br />WATERTIGHT.
<br />c. CUT MORTISES FOR BUTTS USING APPROPRIATE TEMPLATES; UNIVERSAL NON -HANDED
<br />PREPARATION OF DOORS IS NOT ACCEPTABLE.
<br />H. FRAMES:
<br />1. DESIGN: DOUBLE RABBET, EXCEPT FLAT, CASED OPENING FRAME WHERE INDICATED
<br />ON PLANS, UNLESS SPECIFIED OR INDICATED OTHERWISE; FULLY WELDED.
<br />2. GAS:
<br />a. EXTERIOR FRAMES: MINIMUM 14 GA.
<br />b. INTERIOR FRAMES: MINIMUM 16 GA FOR FRAMES OF DOOR OPENINGS UP TO AND
<br />INCLUDING 4 FEET IN WIDTH;14 GA FOR FRAMES GREATER THAN 4 FEET IN WIDTH.
<br />A. FINISH:
<br />1. INTERIOR FRAMES: MANUFACTURER'S STANDARD RUST -INHIBITIVE PRIMER.
<br />2. EXTERIOR FRAMES: HOT DIP GALVANIZED ZINC COATING CONFORMING TO ASTM A653
<br />A60 (.60 OZ/SQ FT. COATING WEIGHT), WITH MANUFACTURER'S STANDARD PRIMER TO
<br />RECEIVE COATING SYSTEM SPECIFIED IN SECTION 099000.
<br />J. INSTALLATION OF FRAMES:
<br />1. INSTALL FRAMES IN ACCORDANCE WITH SDI-105 AND IN ACCORDANCE WITH LABELING
<br />REQUIREMENTS.
<br />2. COORDINATE WITH WALL CONSTRUCTION FOR ANCHOR PLACEMENT.
<br />3. INSTALLATION TOLERANCES; MAXIMUM DIAGONAL DISTORTION: 1/16 INCH MEASURED
<br />WITH STRAIGHT EDGE, CORNER TO CORNER.
<br />4. DOOR AND HARDWARE INSTALLATION IS SPECIFIED IN SECTION 087300.
<br />081400 WOOD DOORS
<br />A. SOLID CORE FLUSH DOORS:
<br />1. 1. APPROVED MANUFACTURERS: ONE OF THE FOLLOWING.
<br />a. ALGOMA HARDWOODS, INC. (ALGOMA WI; 920-487-5221; 800-678-8910).
<br />b. EGGERS INDUSTRIES (TWO RIVERS WI; 920-793-1351).
<br />c. VANCOUVER DOOR (PUYALLUP WA, 800-999-3667)
<br />d. OREGON DOOR (WINSTON OR, 800-722-7269)
<br />2. AWI SECTION 1300, PREMIUM GRADE.
<br />3. CORE: UREA -FORMALDEHYDE FREE, SOLID PARTICLE BOARD CORE, UNLESS REQUIRED
<br />OTHERWISE FOR FIRE LABELING REQUIREMENTS.
<br />4. AWI PC-5 (5 OR 7 PLY CONSTRUCTION).
<br />5. PROVIDE LABELED DOORS AS REQUIRED TO MEET THE HOURLY FIRE RATING
<br />INDICATED.
<br />6. WHERE INTUMESCENT SEALS ARE REQUIRED TO MEET POSITIVE PRESSURE LABELING
<br />REQUIREMENTS, PROVIDE CONCEALED EDGE SEALING SYSTEM BUILT INTO THE DOOR
<br />EDGE.
<br />7. 1-3/4 INCH THICK, UNLESS SCHEDULED OTHERWISE.
<br />8. FRAMES: PROVIDED UNDER SECTION 081113.
<br />B. FABRICATION:
<br />1. FABRICATE DOORS TO THE CONFIGURATIONS INDICATED, IN ACCORDANCE WITH THE
<br />AWI STANDARDS SPECIFIED, AND TO FIRE RATED LABELING REQUIREMENTS. ATTACH
<br />FIRE RATING LABELS.
<br />2. BEVEL LOCK AND HINGE EDGES 1/8 INCH IN 2 INCHES ON ALL SINGLE ACTING DOORS.
<br />r
<br />DIVISION 8 OPEN
<br />INGS NHS C NT,
<br />3. BOND EDGE BANDING TO SOLID CORE WITH HOT MELT OR RF CURED ADHESIVE.
<br />4. PRE -FIT AND PRE -MACHINE DOORS IN ACCORDANCE WITH AWI 1300-S-6. PRE -MACHINE
<br />FOR HARDWARE SPECIFIED IN SECTION 087000, AND LOCATE AS SPECIFIED IN SECTION
<br />087300.
<br />5. DOORS SHALL BE FACTORY PREFINISHED AS SCHEDULED TO MATCH ARCHITECT'S
<br />SAMPLE; AWI PREMIUM GRADE, LOW VOC, POLYURETHANE SYSTEM.
<br />6. WHERE REQUIRED TO MEET LABELING REQUIREMENTS, PROVIDE METAL ASTRAGALS
<br />TO MEET RATING REQUIREMENTS FOR DOUBLE FIRE DOORS.
<br />7. FACTORY PRE -GLAZE DOORS.
<br />8. FLUSH DOOR BLOCKING: FOR FLUSH DOORS, PROVIDE SOLID LOCK BLOCKS AND
<br />SPECIAL BLOCKING AS REQUIRED FOR THE HARDWARE COMPONENTS SPECIFIED
<br />ELSEWHERE. BLOCKING FOR FIRE RATED DOORS SHALL MEET THE DOOR
<br />MANUFACTURER'S LABELING REQUIREMENTS.
<br />C. INSTALLATION:
<br />1. FIT AND PREPARE DOORS FOR INSTALLATION IN ACCORDANCE WITH THE DOOR
<br />MANUFACTURER'S PRINTED INSTRUCTIONS.
<br />2. PROVIDE CLEARANCES OF 1/8 INCH AT JAMBS AND HEADS AND 3/8 INCH FROM BOTTOM
<br />OF DOOR TO TOP OF DECORATIVE FLOOR FINISH OR COVERING, EXCEPT WHERE
<br />THRESHOLD IS SHOWN OR SCHEDULED PROVIDE 1/4 INCH CLEARANCE FROM BOTTOM
<br />OF DOOR TO TOP OF THRESHOLD.
<br />083100 ACCESS DOORS AND PANELS
<br />A. QUALITY ASSURANCE:
<br />1. WHERE ACCESS DOORS ARE INSTALLED IN CONSTRUCTION WITH AN HOURLY FIRE
<br />RESISTANCE RATING, PROVIDE DOOR AND FRAME ASSEMBLIES LABELED BY
<br />UNDERWRITER'S LABORATORY, WARNOCK HERSEY, OR ANY OTHER TESTING
<br />LABORATORY APPROVED BY THE LOCAL CODE AUTHORITIES TO MEET THE
<br />REQUIREMENTS OF THE FIRE RATED ASSEMBLY.
<br />B. ACCEPTABLE MANUFACTURERS:
<br />1. MILCOR, INC., LIMA, OH.
<br />2. J.L. INDUSTRIES, BLOOMINGTON, MN.
<br />3, KARP ASSOCIATES, INC., MASPETH, NY.
<br />4. MM SYSTEMS CORPORATION, TUCKER, GA.
<br />5. NYSTROM, MINNEAPOLIS, MN
<br />C. DOOR TYPES:
<br />1. FIRE RATED METAL ACCESS DOOR FOR USE AT RATED PARTITIONS:
<br />a. FLUSH TYPE DESIGN.
<br />b. 16 GA FRAME; MINIMUM 20 GA STEEL WELDED PAN DOOR PANEL INSULATED WITH
<br />NON-COMBUSTIBLE FILLER
<br />c. SELF CLOSING AND SELF LATCHING, WITH INTERIOR LATCH RELEASE
<br />d. FULLY CONCEALED PIN TYPE HINGES OR CONTINUOUS PIANO HINGE, 175 DEGREE
<br />OPENING.
<br />e. RING TURN LATCH.
<br />2. NON RATED METAL WALL AND CEILING ACCESS DOOR FOR USE AT BACK -OF -HOUSE
<br />(BOH) AREAS:
<br />a. FLUSH TYPE DESIGN.
<br />b. 16 GA STEEL FRAME; 14 GA STEEL DOOR PANEL.
<br />c. FOR INSTALLATION IN DRYWALL: INTEGRAL ATTACHMENT FLANGE AND DRYWALL
<br />BEAD FOR FLUSH INSTALLATION.
<br />d. FULLY CONCEALED PIN TYPE HINGES OR CONTINUOUS PIANO HINGE, 175 DEGREE
<br />OPENING.
<br />e. HARDWARE: SCREW DRIVER SLOT, QUARTER TURN CAM LOCK FOR INTERIOR
<br />LOCATIONS; 2'-0" O.C., MAXIMUM.
<br />3. NON RATED CONCEALED DRYWALL ACCESS DOOR FOR USE AT SALES FLOOR AREAS:
<br />a. RECESSED TYPE DESIGN.
<br />b. MINIMUM 13 GA STEEL FRAME; MINIMUM 16 GA STEEL DOOR PANEL RECESSED TO
<br />RECEIVE DRYWALL.
<br />c. INTEGRAL ATTACHMENT FLANGE AND DRYWALL BEAD FOR FLUSH INSTALLATION.
<br />d. FULLY CONCEALED PIVOT ROD HINGE.
<br />e. LATCHES: SCREW DRIVER OPERATED CAM LATCH.
<br />4. HIGH -SECURITY WALL ACCESS DOOR:
<br />a. KARP ASSOCIATES, INC., "DSB-123SD SECURITY ACCESS DOOR," NYSTROM "HS-GMZ"
<br />OR APPROVED.
<br />b. SIZE: 24 IN X 24 IN.
<br />c. FRAMES: 3/16" X 2" X 2" ANGLE WELDED WITH JOINTS GROUND SMOOTH; APPLIED 1/8"
<br />X 1" X 1" STOP ON FOUR SIDES.
<br />d. DOOR: 10 GA STEEL PLATE.
<br />e. HINGES: PROVIDE FULLY CONCEALED HINGE(S).
<br />f. LOCK: PREPARED FOR INTERCHANGEABLE 5-PIN CYLINDER LOCK, AS SPECIFIED IN
<br />SECTION 087100.
<br />g. WEATHERSTRIP: PROVIDE CONTINUOUS SEAL AS NECESSARY TO MAINTAIN
<br />ASSEMBLY WATERTIGHT WHEN CLOSED.
<br />h. FINISH: FACTORY PRIMED FOR FIELD FINISH WITH MANUFACTURER'S STANDARD
<br />RUST -INHIBITIVE POWDER COAT, COLOR TO MATCH ADJACENT CONSTRUCTION.
<br />D. MINIMUM SIZES: PROVIDE ACCESS DOORS IN SIZES INDICATED. WHEN NOT INDICATED OR
<br />SPECIFIED OTHERWISE, PROVIDE 12" X 12" SIZE FOR HAND ACCESS, AND 24" X 24" SIZE FOR
<br />MAN ENTRY.
<br />E. INSTALLATION:
<br />1. PROVIDE ACCESS DOORS IN THE LOCATIONS INDICATED, AND FOR ACCESS TO
<br />BALANCING AND FIRE DAMPERS, TRAP PRIMERS, VALVES, FANS, TERMINAL UNITS, AND
<br />OTHER EQUIPMENT REQUIRING PERIODIC INSPECTION THROUGH FINISHED WALLS OR
<br />CEILING, WHETHER INDICATED OR NOT.
<br />2. COORDINATE ACCESS REQUIREMENTS WITH OTHER TRADES.
<br />3. PROVIDE CONCEALED DRYWALL ACCESS DOORS UNLESS FIRE RATED ACCESS DOORS
<br />ARE REQUIRED BECAUSE OF FIRE RATED CONSTRUCTION.
<br />083326 OVERHEAD COILING SHUTTERS
<br />A. OVERHEAD COILING SHUTTER ASSEMBLIES SHALL INCLUDE SHUTTERS, GUIDES, BRACKETS,
<br />COUNTERBALANCE, HOOD, MOTOR, CONTROL MECHANISMS, AND OTHER ACCESSORIES
<br />REQUIRED FOR A COMPLETE INSTALLATION.
<br />B. QUALITY ASSURANCE
<br />1. INSTALLERS: INSTALLATION SHALL BE PERFORMED BY A FACTORY TRAINED AND
<br />AUTHORIZED REPRESENTATIVE.
<br />C. APPROVED MANUFACTURER (ONE OF THE FOLLOWING, NO SUBSTITUTIONS):
<br />1. QMI SECURITY SOLUTIONS (ITASCA IL; 630-529-7111)
<br />2. NSBS (800-804-0059) FOR EXTERIOR GRILLS ONLY.
<br />D. SHUTTER TYPE: AS INDICATED AND IN ACCORDANCE WITH T-MOBILE NATIONAL ACCOUNT
<br />REQUIREMENTS.
<br />E. EXAMINATION
<br />1. PRIOR TO STARTING WORK, CAREFULLY INSPECT INSTALLED WORK OF OTHER TRADES
<br />AND VERIFY THAT SUCH WORK IS COMPLETE TO THE POINT WHERE WORK OF THIS
<br />SECTION MAY PROPERLY COMMENCE. NOTIFY THE ARCHITECT IN WRITING OF
<br />CONDITIONS DETRIMENTAL TO THE PROPER AND TIMELY COMPLETION OF THE WORK.
<br />2. DO NOT BEGIN INSTALLATION UNTIL UNSATISFACTORY CONDITIONS ARE RESOLVED.
<br />BEGINNING WORK CONSTITUTES ACCEPTANCE OF SITE CONDITIONS AND
<br />RESPONSIBILITY FOR DEFECTIVE INSTALLATION CAUSED BY PRIOR OBSERVABLE
<br />CONDITIONS.
<br />F. INSTALLATION
<br />1. INSTALL SHUTTER AND OPERATING EQUIPMENT COMPLETE WITH ACCESSORIES IN
<br />ACCORDANCE APPROVED SHOP DRAWINGS, AND MANUFACTURER'S
<br />RECOMMENDATIONS.
<br />G. FIELD QUALITY CONTROL
<br />1. VERIFY THAT MOVING PARTS OPERATE SMOOTHLY, COILING SHUTTERS ARE FREE
<br />FROM WARP, TWISTS, OR DISTORTION, SHUTTERS REMAIN IN REQUIRED POSITION, AND
<br />SAFETY FEATURES FUNCTION PROPERLY.
<br />2. REPAIR DAMAGE TO OVERHEAD COILING SHUTTERS TO MATCH MANUFACTURER'S
<br />ORIGINAL FINISH. REPLACE COMPONENTS WHICH CANNOT BE PROPERLY REPAIRED.
<br />3. ADJUST MECHANISM SO MOVING PARTS OPERATE SMOOTHLY.
<br />H. COLOR
<br />1. PROVIDE ANODIZED ALUMINUM FINISH, REGARDLESS OF STOREFRONT WINDOW
<br />COLOR.
<br />084113 ALUMINUM -FRAMED ENTRANCES AND STOREFRONTS
<br />A. SUMMARY:
<br />1. EXTERIOR ALUMINUM FRAMED STOREFRONT AND WINDOW SYSTEMS.
<br />2. INTERIOR ALUMINUM FRAMED STOREFRONT SYSTEMS.
<br />3. ALUMINUM FRAMED GLASS DOORS.
<br />B. REFERENCES:
<br />1. AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM):
<br />2. B209 - ALUMINUM AND ALUMINUM ALLOY SHEET AND PLATE.
<br />3. B221 - ALUMINUM ALLOY EXTRUDED BARS, RODS, WIRE, SHAPES, AND TUBES.
<br />4. E283 - RATE OF AIR LEAKAGE THROUGH EXTERIOR WINDOWS, CURTAIN WALLS, AND
<br />DOORS.
<br />5. E330 - STRUCTURAL PERFORMANCE OF EXTERIOR WINDOWS, CURTAIN WALLS, AND
<br />DOORS BY UNIFORM STATIC AIR PRESSURE DIFFERENCE.
<br />r
<br />DI1l1S COP NIN C NT SUN � E GS, U
<br />6. ARCHITECTURAL ALUMINUM MANUFACTURER'S ASSOCIATION (AAMA).
<br />C. SYSTEM DESCRIPTION:
<br />1. PERFORMANCE - EXTERIOR ALUMINUM WINDOW AND STOREFRONT SYSTEM:
<br />a. SYSTEM SHALL ACCOMMODATE EXPANSION AND CONTRACTION CAUSED BY A
<br />TEMPERATURE RANGE OF 20 DEGREES TO 140 DEGREES F. WITHOUT DETRIMENTAL
<br />EFFECTS TO COMPONENTS, SEALING SYSTEMS, AND SURROUNDING CONSTRUCTION.
<br />b. DESIGN SYSTEM WITH PROVISIONS TO DRAIN MOISTURE TO THE EXTERIOR OF THE
<br />SYSTEM.
<br />c. AIR INFILTRATION: SHALL NOT EXCEED .05 CFM PER SQUARE FOOT OF FIXED AREA
<br />WHEN TESTED IN ACCORDANCE WITH ASTM E 283,
<br />d. WATER INFILTRATION: NO WATER PENETRATION AT A TEST PRESSURE OF 6.24-LB/SQ
<br />FT. WHEN MEASURED IN ACCORDANCE WITH ASTM E 331.
<br />2. WINDOW AND STOREFRONT STRUCTURAL DESIGN:
<br />a. DESIGN AND SIZE MEMBERS TO WITHSTAND POSITIVE AND NEGATIVE WIND LOADS AS
<br />REQUIRED BY THE CURRENTLY ENFORCED EDITION OF THE BUILDING CODE.
<br />b. LIMIT MULLION DEFLECTION TO 1/175, OR FLEXURE LIMIT OF GLASS WITH FULL
<br />RECOVERY OF GLAZING MATERIALS, WHICHEVER IS LESS.
<br />D. WARRANTY: FURNISH FIVE YEAR WRITTEN WARRANTY EXECUTED TO T-MOBILE, FROM THE
<br />MANUFACTURER OF THE STOREFRONT SYSTEM, AGAINST DEFECTS IN MATERIALS AND
<br />WORKMANSHIP, IN ACCORDANCE WITH DIVISION 1.
<br />E. MATERIALS:
<br />1. EXTRUDED ALUMINUM: ASTM B 221; 6063 T5 ALLOY AND TEMPER.
<br />2. SHEET ALUMINUM: ASTM B 209; 5005-H32 ALLOY, OR APPROVED.
<br />F. COMPONENTS:
<br />1. EXTERIOR STOREFRONT AND WINDOW FRAMING:
<br />a. PARTIAL REPLACEMENT: WHERE NEW ENTRANCE OR FRAMING IS INDICATED TO BE
<br />INSTALLED ALONG WITH EXISTING TO REMAIN, MATCH DIMENSIONS, PROFILE, GLAZING
<br />THICKNESS AND FINISH OF EXISTING ALUMINUM WINDOW FRAMING INDICATED TO
<br />REMAIN.
<br />b. WHERE STOREFRONT SYSTEM AS INDICATED ON THE DRAWINGS IS NEW, PROVIDE
<br />MANUFACTURER'S STANDARD NOMINAL 2" X 4" CENTER -GLAZED THERMALLY BROKEN
<br />STOREFRONT FRAMING SYSTEM.
<br />2. INTERIOR (MALL) STOREFRONT AND WINDOW FRAMING: MANUFACTURER'S STANDARD
<br />NOMINAL 2" X 4" CENTER -GLAZED NON -THERMALLY BROKEN STOREFRONT FRAMING
<br />SYSTEM.
<br />3. ACCEPTABLE MANUFACTURERS: KAWNEER, YKK, EFCO, ARCADIA. UNLESS OTHERWISE
<br />SPECIFIED
<br />4. DOORS: EXTRUDED ALUMINUM FRAME; MEDIUM STILE; PROVIDE WITH SPECIAL 10 INCH
<br />HIGH BOTTOM RAIL.
<br />5. DOOR HARDWARE:
<br />a. PROVIDE MANUFACTURER'S STANDARD OFFSET PIVOT HINGES, UNLESS INDICATED
<br />OTHERWISE ON THE DRAWINGS.
<br />b. MANUFACTURER'S STANDARD WEATHERSTRIPPING, INCLUDING BOTTOM SWEEP.
<br />c. BALANCE OF HARDWARE IS LISTED ON THE DRAWINGS.
<br />d. GLAZING BEADS: MANUFACTURER'S STANDARD EPDM OR NEOPRENE GLAZING BEADS,
<br />FOR A COMPLETE WEATHERPROOF SEAL. FURNISH FOR INSTALLATION AS A PART OF
<br />THE WORK OF SECTION 088000.
<br />G. FABRICATION:
<br />1. FABRICATE FRAMES ALLOWING FOR SHIM SPACING AROUND PERIMETER OF ASSEMBLY,
<br />YET ENABLING INSTALLATION.
<br />2. RIGIDLY FIT JOINTS AND CORNERS. ACCURATELY FIT AND SECURE CORNERS TIGHT.
<br />MAKE CORNER JOINTS FLUSH, HAIRLINE, AND WEATHERPROOF. SEAL JOINTS WITH
<br />SEALANT.
<br />3. PROVIDE DRAINAGE HOLES TO ALLOW WATER TO FLOW TO EXTERIOR.
<br />4. PREPARE COMPONENTS TO RECEIVE ANCHORAGE DEVICES. FABRICATE ANCHORAGE
<br />ITEMS.
<br />5. PROVIDE INTERNAL REINFORCEMENT IN MULLIONS WITH MEMBERS TO MAINTAIN
<br />RIGIDITY. PROVIDE REINFORCING AT ALL DOOR STRIKE JAMBS.
<br />6. FABRICATE STOREFRONT SYSTEM TO ACCOMMODATE HARDWARE USING TEMPLATES
<br />FURNISHED FROM SECTION 087100.
<br />7. FABRICATE CUSTOM EXTRUSIONS, CLOSURES, AND SHEET MATERIALS TO THE SHAPES
<br />INDICATED; FABRICATE FOR ATTACHMENT WITH CONCEALED FASTENERS TO THE
<br />GREATEST POSSIBLE EXTENT.
<br />H. FINISH:
<br />1. ANODIZED FINISH: MANUFACTURER'S STANDARD ANODIZED FINISH; .7 MIL MINIMUM
<br />THICKNESS; CLEAR, UNLESS INDICATED OTHERWISE ON THE DRAWINGS. PROVIDE AT
<br />ALL EXPOSED ALUMINUM SURFACES.
<br />I. INSTALLATION:
<br />1. INSTALL FRAMES, DOORS, AND HARDWARE IN ACCORDANCE WITH MANUFACTURER'S
<br />INSTRUCTIONS.
<br />2. USE ANCHORAGE DEVICES TO SECURELY ATTACH FRAME TO STRUCTURE.
<br />3. ALIGN FRAMES PLUMB AND LEVEL, FREE OF WARP OR TWIST. MAINTAIN DIMENSIONAL
<br />TOLERANCES, ALIGNING WITH ADJACENT WORK.
<br />4. INSTALL ALUMINUM FLASHINGS AT HEAD AND SILL. FINISH TO MATCH STOREFRONT AND
<br />WINDOWS.
<br />5. PERIMETER SEALANT IS PROVIDED UNDER SECTION 079200.
<br />6. ADJUST HARDWARE INSTALLED IN THIS SECTION FOR SMOOTH OPERATION.
<br />7. PROTECT ALUMINUM FROM DISSIMILAR MATERIAL WITH A COATING OF BITUMINOUS
<br />S U
<br />PAINT, A MINIMUM 1-MIL THICKNESS OF ZINC CHROMATE PRIMER, PLASTIC SEPARATOR
<br />MATERIALS, OR ISOLATION TAPE. KEEP ISOLATION MATERIALS UNEXPOSED TO VIEW.
<br />087100 DOOR HARDWARE
<br />A. SUPPLIER: FINISH HARDWARE SHALL BE SUPPLIED BY RECOGNIZED BUILDERS' HARDWARE
<br />SUPPLIER WHO HAS BEEN FURNISHING HARDWARE IN THE SAME AREA AS THE PROJECT
<br />FOR A PERIOD OF NOT LESS THAN TWO YEARS. THE SUPPLIER'S ORGANIZATION SHALL
<br />INCLUDE A MEMBER OF THE AMERICAN SOCIETY OF ARCHITECTURAL HARDWARE
<br />CONSULTANTS WHO IS AVAILABLE AT ALL REASONABLE TIMES DURING THE COURSE OF THE
<br />WORK TO MEET WITH T-MOBILE, ARCHITECT OR CONTRACTOR FOR PROJECT HARDWARE
<br />CONSULTATION.
<br />B. INSTALLER: FINISH HARDWARE SHALL BE INSTALLED ONLY BY EXPERIENCED TRADESMEN IN
<br />COMPLIANCE WITH TRADE UNION JURISDICTIONS, EITHER AT THE DOOR AND FRAME
<br />FABRICATION PLANT OR AT THE PROJECT SITE.
<br />C. CODES:
<br />1. ALL FINISH HARDWARE SHALL COMPLY WITH APPLICABLE LOCAL AND/OR STATE
<br />CURRENT BUILDING CODES.
<br />2. HARDWARE FOR FIRE -RATED OPENINGS SHALL ALSO BE IN COMPLIANCE WITH ALL FIRE
<br />BUILDING CODES APPLICABLE TO THE DISTRICT IN WHICH THE BUILDING IS LOCATED.
<br />PROVIDE ONLY HARDWARE WHICH HAS BEEN TESTED AND LISTED BY UL FOR THE
<br />TYPES AND SIZES OF DOORS REQUIRED, AND WHICH COMPLIES WITH THE
<br />REQUIREMENTS OF THE DOOR AND DOORFRAME LABELS.
<br />3. PROVIDE SMOKE SEALS AS REQUIRED AT EACH FIRE -RATED OPENING.
<br />D. DELIVERY: DELIVER ALL HARDWARE IN MANUFACTURERS' ORIGINAL UNOPENED
<br />UNDAMAGED PACKAGES, CLEARLY IDENTIFYING MANUFACTURER, BRAND NAME, AND
<br />CONTENTS.
<br />E. IN ADDITION TO REQUIRED ONE YEAR WARRANTY UNDER CONDITIONS OF THE CONTRACT,
<br />FURNISH 5-YEAR UNCONDITIONAL GUARANTEES FOR ALL DOOR CLOSERS, UNDER
<br />PROVISIONS OF DIVISION 1.
<br />F. FACTORY REPRESENTATIVES FOR DOOR CLOSERS, EXIT BOLTS, AND LOCKSETS SHALL BE
<br />AVAILABLE DURING THE CONSTRUCTION TO INSTRUCT THE CONTRACTOR ON THE PROPER
<br />METHOD OF INSTALLATION OF THEIR MATERIALS. THEY SHALL INSPECT AND ADJUST THEIR
<br />MATERIALS AT THE COMPLETION OF THE WORK, AND SUPPLY PROPER MAINTENANCE
<br />MANUALS TO T-MOBILE.
<br />G. FURNISH 2 SETS OF SPECIAL TOOLS FOR INSTALLATION AND MAINTENANCE OF HARDWARE.
<br />TOOLS FOR MAINTENANCE AND ADJUSTMENTS ARE TO BE DELIVERED TO T-MOBILE UPON
<br />COMPLETION OF THE WORK.
<br />H. IN GENERAL, UNLESS OTHERWISE INDICATED, FINISHES SHALL BE SATIN CHROME US26D.
<br />I. GENERAL: CONSTRUCTION MASTERKEY ALL LOCKSETS AND CYLINDER ITEMS; PROVIDE 6
<br />CONSTRUCTION MASTERKEYS.
<br />J. KEYING: CONTRACTOR SHALL BE RESPONSIBLE FOR FINAL KEYING, AS FOLLOWS:
<br />1. CONSULT WITH T-MOBILE'S AUTHORIZED REPRESENTATIVE AND PREPARE DETAILED
<br />KEYING SCHEDULE ACCORDINGLY. T-MOBILE'S REPRESENTATIVE WILL COORDINATE
<br />KEYING REQUIREMENTS WITH AUTHORIZED REPRESENTATIVE OF HARDWARE SUPPLIER.
<br />2. STAMP "DO NOT DUPLICATE" ON ALL KEYS.
<br />K. BUTTS:
<br />1. IN THE FOLLOWING PARAGRAPHS WHERE HAGER NUMBERS ARE LISTED, EQUIVALENT
<br />ITEMS OF LAWRENCE, MCKINNEY SALES COMPANY, OR THE STANLEY WORKS MAY BE
<br />SUPPLIED.
<br />2. EXTERIOR DOORS (OUTSWING) 38" WIDE OR LESS SHALL HAVE HAGER BB1191 BUTTS,
<br />SIZE 4 1/2 X 4 1/2.
<br />3. INTERIOR DOORS 38" WIDE OR LESS SHALL HAVE HAGER BB1279 BUTTS, SIZE 4 1/2 X 4
<br />1/2.
<br />4. PROVIDE BUTTS ON EXTERIOR DOORS WITH NON -REMOVABLE PINS (SET SCREW IN
<br />BARREL, PIN NON -REMOVABLE WHEN DOOR IS CLOSED), AND SAFETY STUD.
<br />5. PROVIDE FULL THREADED WOOD SCREWS FOR WOOD DOORS AND/OR JAMBS.
<br />6. BUTT WIDTHS LISTED ARE MINIMUM. PROVIDE BUTTS OF WIDER THROW TO SUITE
<br />CONDITIONS FOR 180° OPERATION OF DOORS, STRUCTURAL CONDITIONS PERMITTING.
<br />D,1.ISION $ - OPENINGSI CUNT, -
<br />L. LOCKSETS, DEADLOCKS, CYLINDERS AND PADLOCKS:
<br />1. MANUFACTURER:
<br />A. LOCKS AND DEADLOCKS - AS NOTED IN HARDWARE SCHEDULE ON DRAWINGS
<br />B. CYLINDERS AND PADLOCKS - AS NOTED IN HARDWARE SCHEDULE ON DRAWINGS
<br />2. PROVIDE NEW CYLINDER AT EACH EXISTING DOOR THAT HAS DEADLOCK OR LOCKSET.
<br />3. PROVIDE LOCK STRIKES WITH MINIMUM PROJECTION TO PROTECT TRIM.
<br />4. PROVIDE WROUGHT BOXES FOR LOCKSETS AND DEADLOCKS.
<br />5. PROVIDE DEADLOCKS WITH ARMORED FRONTS.
<br />6. FUNCTION AS INDICATED IN HARDWARE GROUPS.
<br />7. DEAD BOLTS AT EXTERIOR DOORS SHALL HAVE A MINIMUM THROW OF 1 INCH AND
<br />MINIMUM EMBEDMENT OF % INCH.
<br />8. TYPES: AS INDICATED ON THE DRAWINGS.
<br />M. ELECTRONIC HARDWARE
<br />1. TYPES: AS INDICATED ON THE DRAWINGS.
<br />N. DOOR CLOSERS:
<br />1. MANUFACTURERS:
<br />a. OVERHEAD CLOSERS: LCN OR RIXSON.
<br />b. FLOOR CLOSERS: LCN OR RIXSON.
<br />2. ALL OVERHEAD CLOSERS TO BE MOUNTED ON INTERIOR SIDE OF DOOR. NO THRU
<br />BOLTS.
<br />3. PROVIDE MOUNTING BRACKETS AND PROPER LENGTH ARMS TO SUIT ALL CONDITIONS.
<br />PROVIDE ARM OPTIONS AS SCHEDULED OR RECOMMENDED BY MANUFACTURER.
<br />FINISH SHALL MATCH LOCKSETS
<br />4. SIZES SHALL BE AS RECOMMENDED BY THE MANUFACTURER. CLOSERS SHALL HAVE A
<br />5-YEAR UNCONDITIONAL GUARANTEE.
<br />5. PROVIDE STANDARD FULL COVERS AT OVERHEAD CLOSERS; FINISH TO MATCH ARMS,
<br />UNLESS OTHERWISE INDICATED.
<br />6. CLOSURE PRESSURE: SET TO 5 POUNDS FOR BOTH EXTERIOR AND INTERIOR DOORS,
<br />PER CURRENT REQUIREMENTS OF THE AMERICANS WITH DISABILITIES ACT, UNLESS
<br />REQUIRED OTHERWISE BY LOCAL JURISDICTIONAL AUTHORITIES.
<br />7. TYPES: AS INDICATED ON THE DRAWINGS.
<br />0. DOOR STOPS AND OVERHEAD STOPS: AS SCHEDULED.
<br />1. LOCATE FLOOR STOPS FREE FROM FOOT TRAFFIC.
<br />2. TYPES: AS INDICATED ON THE DRAWINGS.
<br />P. PUSH/PULL BARS AND SETS:
<br />1. TYPES: AS INDICATED ON THE DRAWINGS.
<br />Q. WEATHERSTRIP, THRESHOLDS, DOOR BOTTOM AND GASKETS:
<br />1. MANUFACTURER: PEMKO MFG. CO., OR APPROVED EQUAL BY RIXSON.
<br />2. TYPES: AS INDICATED ON THE DRAWINGS.
<br />R. MISCELLANEOUS:
<br />1. PROVIDE SILENCERS FOR ALL DOORJAMBS, 3 FOR SINGLE JAMBS AND 4 FOR DOUBLE
<br />JAMBS.
<br />2. TYPES: AS INDICATED ON THE DRAWINGS.
<br />S. FURNISH FOR EACH DOOR THE ITEMS SCHEDULED WITHIN THE DESIGNATED HARDWARE
<br />GROUPS AS SHOWN ON THE DRAWINGS.
<br />T. ADJUSTMENTS AND TESTING:
<br />1. ADJUST AND CHECK EACH OPERATING ITEM OF HARDWARE AND EACH DOOR TO
<br />ENSURE PROPER OPERATION OF FUNCTION OF EVERY UNIT,
<br />2. LUBRICATE MOVING PARTS WITH GRAPHITE TYPE LUBRICANT UNLESS OTHERWISE
<br />RECOMMENDED BY THE HARDWARE MANUFACTURER.
<br />3. REPLACE UNITS WHICH CANNOT BE ADJUSTED AND LUBRICATED TO OPERATE FREELY
<br />AND SMOOTHLY AS INTENDED FOR THE APPLICATION MADE.
<br />4. ADJUST CLOSER PRESSURES AS SPECIFIED IN SECTION 087100, UNLESS OTHERWISE
<br />REQUIRED BY JURISDICTIONAL AUTHORITIES.
<br />5. TESTING:
<br />a. TEST CLOSER FOR COMPLIANCE WITH REQUIREMENTS OF SECTION 087100, INCLUDING
<br />OPENING FORCE AND CLOSING SPEED REQUIRED BY JURISDICTIONAL AUTHORITIES.
<br />b. PROVIDE TESTING DEVICE, OPERATE TEST AT EACH DOOR, AND PROVIDE A WRITTEN
<br />REPORT ON RESULTS OF TESTS.
<br />c. TESTING DEVICE SHALL REMAIN IN THE POSSESSION OF T-MOBILE.
<br />087300 DOOR AND HARDWARE INSTALLATION
<br />A. QUALITY ASSURANCE: INSTALLERS OF DOORS AND FINISH HARDWARE SHALL BE SKILLED
<br />MECHANICS REGULARLY EMPLOYED IN THE DOOR HARDWARE INDUSTRY AND
<br />EXPERIENCED IN THE INSTALLATION OF DOORS AND DOOR HARDWARE.
<br />B. DOORS, FRAMES, AND HARDWARE: SPECIFIED IN OTHER SECTIONS.
<br />C. DOOR AND HARDWARE INSTALLATION
<br />1. FIT AND PREPARE DOORS FOR INSTALLATION IN ACCORDANCE WITH THE DOOR
<br />MANUFACTURER'S PRINTED INSTRUCTIONS.
<br />2. INSTALL DOORS PLUMB AND SQUARE.
<br />3. PROVIDE CLEARANCES OF 1/8 INCH AT JAMBS AND HEADS, 1/8 INCH AT MEETING STILES
<br />FOR PAIRS OF DOORS, AND 1/2 INCH FROM BOTTOM OF DOOR TO TOP OF DECORATIVE
<br />FLOOR FINISH OR COVERING, EXCEPT WHERE THRESHOLD IS SHOWN OR SCHEDULED
<br />PROVIDE 1/4-INCH CLEARANCE FROM BOTTOM OF DOOR TO TOP OF THRESHOLD.
<br />4. INSTALL ROSES, KICK PLATES, CLOSERS, AND OTHER SURFACE MOUNTED HARDWARE
<br />ONLY AFTER DOOR FINISHING IS COMPLETE AND FINISHES ARE COMPLETELY CURED.
<br />5. FIT HOLLOW METAL DOORS IN ACCORDANCE WITH SDI 100.
<br />6. FINISH HARDWARE INSTALLATION
<br />a. INSTALLER SHALL RECEIVE DELIVERY AND UNPACK, TAG, INDEX, AND FILE ALL KEYS. KEEP
<br />HARDWARE IN A SEPARATE ROOM UNDER LOCK AND KEY AT THE SITE UNTIL
<br />INSTALLATION IS MADE.
<br />b. VERIFY ALL DIMENSIONS AND BE RESPONSIBLE FOR THE CORRECT INSTALLATION AND FIT
<br />OF HARDWARE AT THE LOCATIONS INDICATED ON THE DRAWINGS AND AS SPECIFIED.
<br />c. INSTALL EACH HARDWARE ITEM IN COMPLIANCE WITH THE MANUFACTURER'S
<br />INSTRUCTIONS AND RECOMMENDATIONS.
<br />d. WHEREVER CUTTING AND FITTING ARE REQUIRED TO INSTALL HARDWARE ONTO OR INTO
<br />SURFACES WHICH ARE LATER TO BE PAINTED OR FINISHED IN ANOTHER WAY, INSTALL
<br />EACH ITEM COMPLETELY AND THEN REMOVE AND STORE IN A SECURE PLACE DURING
<br />THE FINISH APPLICATION. AFTER COMPLETION OF THE FINISHES, REINSTALL EACH ITEM.
<br />DO NOT INSTALL SURFACE -MOUNTED ITEMS UNTIL FINISHES HAVE BEEN COMPLETED ON
<br />THE SUBSTRATE.
<br />e. HARDWARE MOUNTING HEIGHTS: AS INDICATED. WHERE NOT INDICATED, COMPLY WITH
<br />RECOMMENDATIONS OF THE NATIONAL BUILDERS HARDWARE ASSOCIATION (NBHA).
<br />7. ADJUSTMENT AND CLEANING: ADJUST AND CHECK EACH OPERATING ITEM OF
<br />HARDWARE AND EACH DOOR TO ENSURE PROPER OPERATION OF FUNCTION OF EVERY
<br />UNIT. LUBRICATE MOVING PARTS WITH GRAPHITE TYPE LUBRICANT UNLESS
<br />OTHERWISE RECOMMENDED BY THE HARDWARE MANUFACTURER. REPLACE UNITS
<br />WHICH CANNOT BE ADJUSTED AND LUBRICATED TO OPERATE FREELY AND SMOOTHLY
<br />AS INTENDED FOR THE APPLICATION MADE.
<br />088000 GLAZING
<br />A. GLASS: PROVIDE THE FOLLOWING GLASS AS SCHEDULED ON THE DRAWINGS:
<br />1. CLEAR GLASS: ASTM C1036, TYPE I, CLASS 1, CLEAR, QUALITY Q3 GLAZING SELECT.
<br />B. PLASTIC GLAZING: ACRYLIC PANEL AS SCHEDULED ON THE DRAWINGS.
<br />C. ACCESSORIES:
<br />1. SILICONE SEALANT: DOW CORNING "795"; CLEAR COLOR.
<br />2. SETTING BLOCKS: COMPATIBLE WITH SILICONE SEALANTS; 70-90 SHORE A HARDNESS.
<br />3. SPACERS: COMPATIBLE WITH SILICONE SEALANT.
<br />4. GLAZING TAPE: TREMCO "CCN" SPONGE, OR APPROVED.
<br />5. GLAZING CHANNELS: EXTRUDED ALUMINUM; PROFILE AS INDICATED ON THE
<br />DRAWINGS; CLEAR ANODIZED FINISH.
<br />D. FABRICATION:
<br />1. INSULATING GLASS UNITS:
<br />a. DUAL LITE UNITS FABRICATED FROM GLASS AS SCHEDULED; 1/2 INCH NOMINAL AIRSPACE;
<br />DUAL SEAL SYSTEM.
<br />b. TWIN SEALS; POLYISOBUTYLENE PRIMARY SEAL AND SILICONE SECONDARY SEAL. OUTER
<br />SEAL SHALL BE COMPATIBLE WITH GLAZING SYSTEM.
<br />c. SPACER BAR: MILL FINISH ALUMINUM; FILL WITH DESICCANT; CORNERS SHALL BE
<br />PARTIALLY MITER CUT AND BENT (NOT CUT THROUGH), OR FORMED WITH CORNER KEYS
<br />ULTRASONICALLY SOLDERED IN PLACE.
<br />d. CERTIFIED THROUGH THE INSULATING GLASS CERTIFICATION COUNCIL (IG.C.C) IN
<br />ACCORDANCE WITH ASTM E773 AND E774; CERTIFIED TO LEVEL CBA.
<br />e. EACH PIECE SHALL BEAR CERTIFICATION NUMBER, DATE, AND MANUFACTURER'S
<br />IDENTIFICATION MARK.
<br />2. TEMPERED AND HEAT STRENGTHENED GLASS:
<br />a. TEMPERED GLASS: GLASS WHICH HAS BEEN HEAT TREATED TO STRENGTHEN GLASS IN
<br />BENDING TO NOT LESS THAN 4 TIMES THE ANNEALED STRENGTH; CERTIFIED SAFETY
<br />GLASS IN ACCORDANCE WITH ANSI Z97.1.
<br />b. HEAT STRENGTHENED GLASS: ASTM C1048; GLASS WHICH HAS BEEN HEAT TREATED TO
<br />STRENGTHEN GLASS IN BENDING TO NOT LESS THAN 2 TIMES ANNEALED STRENGTH.
<br />c. FABRICATE TEMPERED AND HEAT STRENGTHENED GLASS UNITS SO THAT PRINCIPLE
<br />DISTORTION WILL BE IN THE HORIZONTAL DIRECTION IN THE FINISHED INSTALLATION.
<br />d. UNLESS OTHERWISE APPROVED BY THE BUILDING OFFICIAL, PROVIDE MANUFACTURER'S
<br />LABEL ON EACH LIGHT, INDICATING TYPE AND THICKNESS OF GLASS.
<br />Mobi*le"
<br />12920 SE 38th STREET
<br />BELLEVUE, WA 98006
<br />www.T-Mobile.com
<br />COPYRIGHT NOTICE
<br />THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO
<br />COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF
<br />THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED JANUARY 2003. THE PROTECTION
<br />INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND
<br />COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH
<br />PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS
<br />MAY RESULT IN CESSATION OF CONSTRUCTION, BUILDING SEIZURE, AND/OR
<br />MONETARY LIABILITY.
<br />ARCHITECT
<br />rmUzioN
<br />9096 EAST BAHIA DRIVE
<br />SUITE 103
<br />SCOTTSDALE, AZ 85260
<br />DESIGN@FUZIONVE.COM
<br />WWW.FUZIONVE.COM
<br />VENDOR PROJECT NO: 21.11.212680
<br />E CF. F
<br />OLQU
<br />�4 ✓C .
<br />ti,
<br />�0K 0 4
<br />'SrFR -D A�G��
<br />02/10/2022
<br />CONSULTING ENGINEER:
<br />CV
<br />W
<br />Q
<br />Lu
<br />Q r
<br />Z Q M
<br />W > cM
<br />o Lu JJ
<br />.j 5
<br />O J
<br />m �
<br />od
<br />� J -
<br />� J �
<br />♦♦a^^
<br />V
<br />00
<br />> N W
<br />-JN
<br />J
<br />♦Q
<br />V
<br />DATE: February 5, 2022
<br />SCALE: AS NOTED
<br />DRAWN BY: LEO V.
<br />SAP NUMBER:
<br />4SIR
<br />CORPORATE TENANT REBUILD
<br />LDC
<br />SHEET TITLE:
<br />SPECIFICATIONS
<br />SHEET NUMBER:
<br />4
<br />3
<br />e
<br />1
<br />A703
<br />
|