Laserfiche WebLink
4 <br />1 11 I 11 I 1 L I I I I I I II II III IT I, I , ! I I I I I 1 ,I P I I I 1 11,1 1 I I 1 11 <br />3 I 2 <br />LII <br />UI <br />Im I <br />¢I <br />DIVISION 7w <br />THERMAL AL ANDMOISTIE , CUNT <br />4. TYPE A: ASTM C834; TREMCO "ACRYLIC LATEX CAULK", PECORA "AC-20", SONNEBORN <br />"SONOLAC" OR APPROVED. <br />5. TYPE SM: MILDEW RESISTANT SILICONE SEALANT: USDA APPROVED; DOW CORNING 786 <br />BY DOW CHEMICAL, GE SANITARY SEALANT OR APPROVED; CLEAR. <br />C. ACCESSORY MATERIALS: <br />1. PRIMER: NON -STAINING TYPE, RECOMMENDED BY SEALANT MANUFACTURER TO SUIT <br />APPLICATION. <br />2. JOINT CLEANER: NON -CORROSIVE AND NON -STAINING TYPE, RECOMMENDED BY <br />SEALANT MANUFACTURER; COMPATIBLE WITH JOINT FORMING MATERIALS. <br />3. JOINT FILLER: CLOSED CELL POLYETHYLENE FOAM; ROUND PROFILE; THICKNESS: 130%%% <br />OF JOINT WIDTH. <br />4. BOND BREAKER: PRESSURE SENSITIVE TAPE RECOMMENDED BY SEALANT <br />MANUFACTURER TO SUIT APPLICATION. <br />5. COMPRESSIBLE FOAM SEALANT: PRECOMPRESSED PREFACED SELF-ADHESIVE OPEN <br />CELL POLYURETHANE FOAM TAPE; "BACKERSEAL" BY EMSEAL JOINT SYSTEMS, LTD., <br />OR APPROVED. <br />D. PREPARATION: <br />1. CLEAN AND PREPARE JOINTS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. <br />REMOVE LOOSE MATERIALS AND OTHER FOREIGN MATTER WHICH MIGHT IMPAIR <br />ADHESION OF SEALANT. <br />2. APPLY MASKING TIGHTLY AROUND JOINTS TO PROTECT ADJACENT SURFACES FROM <br />EXCESS SEALANT. <br />3. PRIME AS REQUIRED FOR PROPER BOND TO SUBSTRATE MATERIALS. <br />E. INSTALLATION: <br />1. PERFORM WORK IN ACCORDANCE WITH ASTM C1193, UNLESS SPECIFIED OTHERWISE <br />OR RECOMMENDED OTHERWISE BY THE SEALANT MANUFACTURER. <br />2. SEALANT BEADS SHALL HAVE A SECTIONAL WIDTH TO DEPTH RATIO OF 2 TO 1, EXCEPT <br />THAT SEALANT TYPE PT SHALL BE INSTALLED FULL DEPTH WITHOUT BACKING. <br />3. INSTALL TYPE PTNS SEALANT FULL DEPTH IN TILE EXPANSION JOINTS WITH NO BACKER <br />ROD. <br />4. TOOL JOINTS CONCAVE, UNLESS INDICATED OTHERWISE. FINISH FREE OF AIR <br />POCKETS, FOREIGN EMBEDDED MATTER, RIDGES, AND SAGS. <br />5. PROTECT SEALANT IN JOINTS SUBJECT TO DIRT, MOISTURE, AND TRAFFIC DURING THE <br />SEALANT CURING PROCESS. PROTECTION SHALL BE ABLE TO RESIST TRAFFIC WHILE <br />REMAINING SECURELY IN POSITION. <br />F. SCHEDULE: <br />1. TYPE S: PROVIDE AT ALL EXTERIOR JOINTS UNLESS SPECIFIED OTHERWISE; <br />STANDARD COLORS AS SELECTED BY ARCHITECT. <br />2. TYPE PT: PROVIDE AT ALL EXTERIOR HORIZONTAL JOINTS SUBJECT TO TRAFFIC AND <br />ABRASION; STANDARD COLORS AS SELECTED BY ARCHITECT. <br />3. TYPE PTNS: PROVIDE AT ALL EXPANSION JOINTS IN TILE; CUSTOM COLORS TO MATCH <br />GROUT SAMPLES SUBMITTED BY TILE INSTALLER. <br />4. TYPE A: PROVIDE AT ALL INTERIOR JOINTS, UNLESS SPECIFIED OTHERWISE; STANDARD <br />COLORS TO MATCH ADJACENT CONSTRUCTION. <br />5. TYPE SM: PROVIDE AT JOINTS AROUND COUNTERTOPS IN BACH OF HOUSE (BOH) AND <br />RESTROOMS. <br />DIvISI N $ OPENINGS <br />081113 HOLLOW METAL DOORS AND FRAMES <br />A. SUMMARY: <br />1. INTERIOR DOOR FRAMES TO BE NOTED ON DOOR SCHEDULE PROVIDE "TIMELY" (OR <br />EQUAL) PRE -FINISHED DOOR FRAME SYSTEMS (METAL) FOR <br />2. EXTERIOR DOORS AND FRAMES, WHEN INDICATED ON THE DRAWINGS. <br />B. REGULATORY REQUIREMENTS: <br />1. WHERE REQUIRED, INSTALLED FRAME AND DOOR ASSEMBLY SHALL CONFORM TO <br />NFPA 80 FOR FIRE RATED CLASS INDICATED. <br />2. WHERE DOORS ARE NOTED WITH AN HOURLY FIRE RESISTANCE RATING, PROVIDE <br />DOOR AND FRAME ASSEMBLIES LABELED BY UNDERWRITER'S LABORATORY (UL), OR <br />ANOTHER TESTING LABORATORY APPROVED BY THE LOCAL CODE AUTHORITIES, TO <br />MEET THE HOURLY FIRE RATING NOTED. ASSEMBLIES SHALL MEET CODE <br />REQUIREMENTS FOR POSITIVE PRESSURE WHEN REQUIRED. <br />3. INCLUDE "S" LABEL ON FIRE RATED DOOR ASSEMBLIES LOCATED AT 1 HOUR RATED <br />EXIT CORRIDORS. <br />C. QUALITY ASSURANCE: <br />1. CONFORM TO REQUIREMENTS OF ANSI A250.8. <br />D. ACCEPTABLE MANUFACTURERS: MEMBERS OF THE STEEL DOOR INSTITUTE AND OF THE <br />NATIONAL ASSOCIATION OF ARCHITECTURAL METAL MANUFACTURERS, SUBJECT TO <br />COMPLIANCE WITH SPECIFIED REQUIREMENTS. <br />E. MATERIALS: STEEL SHEET, COLD ROLLED ASTM A366, OR HOT ROLLED PICKLED AND OILED <br />SHEET CONFORMING TO ASTM A 569, MINIMUM 30% RECYCLED CONTENT. <br />F. INTERIOR DOOR CONSTRUCTION: <br />1. ANSI A250.8; SEAMLESS; MINIMUM 18 GA FACE SHEETS, 16 GA AT INVENTORY ROOM. <br />2. CORE: VERTICAL STEEL STIFFENERS WITH SOUND DEADENING FILL BETWEEN <br />STIFFENERS, OR RESIN IMPREGNATED KRAFT PAPER HONEY COMB CORE. <br />3. PROVIDE CONTINUOUSLY WELDED SEAMLESS EDGES. NO PLASTIC FILLERS WILL BE <br />ACCEPTED. <br />G. EXTERIOR DOOR CONSTRUCTION: <br />1. ANSI A250.8; SEAMLESS; MINIMUM 16 GA FACE SHEETS. <br />2. CORE: POLYSTYRENE OR POLYURETHANE FOAM CORE. <br />3. SPECIAL CONSTRUCTION REQUIREMENTS: <br />a. PROVIDE CONTINUOUSLY WELDED SEAMLESS EDGES. NO PLASTIC FILLERS WILL BE <br />ACCEPTED. <br />b. CLOSE TOP EDGES OF EXTERIOR DOORS FLUSH WITH STEEL FILLER CAP; SEAL JOINTS <br />WATERTIGHT. <br />c. CUT MORTISES FOR BUTTS USING APPROPRIATE TEMPLATES; UNIVERSAL NON -HANDED <br />PREPARATION OF DOORS IS NOT ACCEPTABLE. <br />H. FRAMES: <br />1. DESIGN: DOUBLE RABBET, EXCEPT FLAT, CASED OPENING FRAME WHERE INDICATED <br />ON PLANS, UNLESS SPECIFIED OR INDICATED OTHERWISE; FULLY WELDED. <br />2. GAS: <br />a. EXTERIOR FRAMES: MINIMUM 14 GA. <br />b. INTERIOR FRAMES: MINIMUM 16 GA FOR FRAMES OF DOOR OPENINGS UP TO AND <br />INCLUDING 4 FEET IN WIDTH;14 GA FOR FRAMES GREATER THAN 4 FEET IN WIDTH. <br />A. FINISH: <br />1. INTERIOR FRAMES: MANUFACTURER'S STANDARD RUST -INHIBITIVE PRIMER. <br />2. EXTERIOR FRAMES: HOT DIP GALVANIZED ZINC COATING CONFORMING TO ASTM A653 <br />A60 (.60 OZ/SQ FT. COATING WEIGHT), WITH MANUFACTURER'S STANDARD PRIMER TO <br />RECEIVE COATING SYSTEM SPECIFIED IN SECTION 099000. <br />J. INSTALLATION OF FRAMES: <br />1. INSTALL FRAMES IN ACCORDANCE WITH SDI-105 AND IN ACCORDANCE WITH LABELING <br />REQUIREMENTS. <br />2. COORDINATE WITH WALL CONSTRUCTION FOR ANCHOR PLACEMENT. <br />3. INSTALLATION TOLERANCES; MAXIMUM DIAGONAL DISTORTION: 1/16 INCH MEASURED <br />WITH STRAIGHT EDGE, CORNER TO CORNER. <br />4. DOOR AND HARDWARE INSTALLATION IS SPECIFIED IN SECTION 087300. <br />081400 WOOD DOORS <br />A. SOLID CORE FLUSH DOORS: <br />1. 1. APPROVED MANUFACTURERS: ONE OF THE FOLLOWING. <br />a. ALGOMA HARDWOODS, INC. (ALGOMA WI; 920-487-5221; 800-678-8910). <br />b. EGGERS INDUSTRIES (TWO RIVERS WI; 920-793-1351). <br />c. VANCOUVER DOOR (PUYALLUP WA, 800-999-3667) <br />d. OREGON DOOR (WINSTON OR, 800-722-7269) <br />2. AWI SECTION 1300, PREMIUM GRADE. <br />3. CORE: UREA -FORMALDEHYDE FREE, SOLID PARTICLE BOARD CORE, UNLESS REQUIRED <br />OTHERWISE FOR FIRE LABELING REQUIREMENTS. <br />4. AWI PC-5 (5 OR 7 PLY CONSTRUCTION). <br />5. PROVIDE LABELED DOORS AS REQUIRED TO MEET THE HOURLY FIRE RATING <br />INDICATED. <br />6. WHERE INTUMESCENT SEALS ARE REQUIRED TO MEET POSITIVE PRESSURE LABELING <br />REQUIREMENTS, PROVIDE CONCEALED EDGE SEALING SYSTEM BUILT INTO THE DOOR <br />EDGE. <br />7. 1-3/4 INCH THICK, UNLESS SCHEDULED OTHERWISE. <br />8. FRAMES: PROVIDED UNDER SECTION 081113. <br />B. FABRICATION: <br />1. FABRICATE DOORS TO THE CONFIGURATIONS INDICATED, IN ACCORDANCE WITH THE <br />AWI STANDARDS SPECIFIED, AND TO FIRE RATED LABELING REQUIREMENTS. ATTACH <br />FIRE RATING LABELS. <br />2. BEVEL LOCK AND HINGE EDGES 1/8 INCH IN 2 INCHES ON ALL SINGLE ACTING DOORS. <br />r <br />DIVISION 8 OPEN <br />INGS NHS C NT, <br />3. BOND EDGE BANDING TO SOLID CORE WITH HOT MELT OR RF CURED ADHESIVE. <br />4. PRE -FIT AND PRE -MACHINE DOORS IN ACCORDANCE WITH AWI 1300-S-6. PRE -MACHINE <br />FOR HARDWARE SPECIFIED IN SECTION 087000, AND LOCATE AS SPECIFIED IN SECTION <br />087300. <br />5. DOORS SHALL BE FACTORY PREFINISHED AS SCHEDULED TO MATCH ARCHITECT'S <br />SAMPLE; AWI PREMIUM GRADE, LOW VOC, POLYURETHANE SYSTEM. <br />6. WHERE REQUIRED TO MEET LABELING REQUIREMENTS, PROVIDE METAL ASTRAGALS <br />TO MEET RATING REQUIREMENTS FOR DOUBLE FIRE DOORS. <br />7. FACTORY PRE -GLAZE DOORS. <br />8. FLUSH DOOR BLOCKING: FOR FLUSH DOORS, PROVIDE SOLID LOCK BLOCKS AND <br />SPECIAL BLOCKING AS REQUIRED FOR THE HARDWARE COMPONENTS SPECIFIED <br />ELSEWHERE. BLOCKING FOR FIRE RATED DOORS SHALL MEET THE DOOR <br />MANUFACTURER'S LABELING REQUIREMENTS. <br />C. INSTALLATION: <br />1. FIT AND PREPARE DOORS FOR INSTALLATION IN ACCORDANCE WITH THE DOOR <br />MANUFACTURER'S PRINTED INSTRUCTIONS. <br />2. PROVIDE CLEARANCES OF 1/8 INCH AT JAMBS AND HEADS AND 3/8 INCH FROM BOTTOM <br />OF DOOR TO TOP OF DECORATIVE FLOOR FINISH OR COVERING, EXCEPT WHERE <br />THRESHOLD IS SHOWN OR SCHEDULED PROVIDE 1/4 INCH CLEARANCE FROM BOTTOM <br />OF DOOR TO TOP OF THRESHOLD. <br />083100 ACCESS DOORS AND PANELS <br />A. QUALITY ASSURANCE: <br />1. WHERE ACCESS DOORS ARE INSTALLED IN CONSTRUCTION WITH AN HOURLY FIRE <br />RESISTANCE RATING, PROVIDE DOOR AND FRAME ASSEMBLIES LABELED BY <br />UNDERWRITER'S LABORATORY, WARNOCK HERSEY, OR ANY OTHER TESTING <br />LABORATORY APPROVED BY THE LOCAL CODE AUTHORITIES TO MEET THE <br />REQUIREMENTS OF THE FIRE RATED ASSEMBLY. <br />B. ACCEPTABLE MANUFACTURERS: <br />1. MILCOR, INC., LIMA, OH. <br />2. J.L. INDUSTRIES, BLOOMINGTON, MN. <br />3, KARP ASSOCIATES, INC., MASPETH, NY. <br />4. MM SYSTEMS CORPORATION, TUCKER, GA. <br />5. NYSTROM, MINNEAPOLIS, MN <br />C. DOOR TYPES: <br />1. FIRE RATED METAL ACCESS DOOR FOR USE AT RATED PARTITIONS: <br />a. FLUSH TYPE DESIGN. <br />b. 16 GA FRAME; MINIMUM 20 GA STEEL WELDED PAN DOOR PANEL INSULATED WITH <br />NON-COMBUSTIBLE FILLER <br />c. SELF CLOSING AND SELF LATCHING, WITH INTERIOR LATCH RELEASE <br />d. FULLY CONCEALED PIN TYPE HINGES OR CONTINUOUS PIANO HINGE, 175 DEGREE <br />OPENING. <br />e. RING TURN LATCH. <br />2. NON RATED METAL WALL AND CEILING ACCESS DOOR FOR USE AT BACK -OF -HOUSE <br />(BOH) AREAS: <br />a. FLUSH TYPE DESIGN. <br />b. 16 GA STEEL FRAME; 14 GA STEEL DOOR PANEL. <br />c. FOR INSTALLATION IN DRYWALL: INTEGRAL ATTACHMENT FLANGE AND DRYWALL <br />BEAD FOR FLUSH INSTALLATION. <br />d. FULLY CONCEALED PIN TYPE HINGES OR CONTINUOUS PIANO HINGE, 175 DEGREE <br />OPENING. <br />e. HARDWARE: SCREW DRIVER SLOT, QUARTER TURN CAM LOCK FOR INTERIOR <br />LOCATIONS; 2'-0" O.C., MAXIMUM. <br />3. NON RATED CONCEALED DRYWALL ACCESS DOOR FOR USE AT SALES FLOOR AREAS: <br />a. RECESSED TYPE DESIGN. <br />b. MINIMUM 13 GA STEEL FRAME; MINIMUM 16 GA STEEL DOOR PANEL RECESSED TO <br />RECEIVE DRYWALL. <br />c. INTEGRAL ATTACHMENT FLANGE AND DRYWALL BEAD FOR FLUSH INSTALLATION. <br />d. FULLY CONCEALED PIVOT ROD HINGE. <br />e. LATCHES: SCREW DRIVER OPERATED CAM LATCH. <br />4. HIGH -SECURITY WALL ACCESS DOOR: <br />a. KARP ASSOCIATES, INC., "DSB-123SD SECURITY ACCESS DOOR," NYSTROM "HS-GMZ" <br />OR APPROVED. <br />b. SIZE: 24 IN X 24 IN. <br />c. FRAMES: 3/16" X 2" X 2" ANGLE WELDED WITH JOINTS GROUND SMOOTH; APPLIED 1/8" <br />X 1" X 1" STOP ON FOUR SIDES. <br />d. DOOR: 10 GA STEEL PLATE. <br />e. HINGES: PROVIDE FULLY CONCEALED HINGE(S). <br />f. LOCK: PREPARED FOR INTERCHANGEABLE 5-PIN CYLINDER LOCK, AS SPECIFIED IN <br />SECTION 087100. <br />g. WEATHERSTRIP: PROVIDE CONTINUOUS SEAL AS NECESSARY TO MAINTAIN <br />ASSEMBLY WATERTIGHT WHEN CLOSED. <br />h. FINISH: FACTORY PRIMED FOR FIELD FINISH WITH MANUFACTURER'S STANDARD <br />RUST -INHIBITIVE POWDER COAT, COLOR TO MATCH ADJACENT CONSTRUCTION. <br />D. MINIMUM SIZES: PROVIDE ACCESS DOORS IN SIZES INDICATED. WHEN NOT INDICATED OR <br />SPECIFIED OTHERWISE, PROVIDE 12" X 12" SIZE FOR HAND ACCESS, AND 24" X 24" SIZE FOR <br />MAN ENTRY. <br />E. INSTALLATION: <br />1. PROVIDE ACCESS DOORS IN THE LOCATIONS INDICATED, AND FOR ACCESS TO <br />BALANCING AND FIRE DAMPERS, TRAP PRIMERS, VALVES, FANS, TERMINAL UNITS, AND <br />OTHER EQUIPMENT REQUIRING PERIODIC INSPECTION THROUGH FINISHED WALLS OR <br />CEILING, WHETHER INDICATED OR NOT. <br />2. COORDINATE ACCESS REQUIREMENTS WITH OTHER TRADES. <br />3. PROVIDE CONCEALED DRYWALL ACCESS DOORS UNLESS FIRE RATED ACCESS DOORS <br />ARE REQUIRED BECAUSE OF FIRE RATED CONSTRUCTION. <br />083326 OVERHEAD COILING SHUTTERS <br />A. OVERHEAD COILING SHUTTER ASSEMBLIES SHALL INCLUDE SHUTTERS, GUIDES, BRACKETS, <br />COUNTERBALANCE, HOOD, MOTOR, CONTROL MECHANISMS, AND OTHER ACCESSORIES <br />REQUIRED FOR A COMPLETE INSTALLATION. <br />B. QUALITY ASSURANCE <br />1. INSTALLERS: INSTALLATION SHALL BE PERFORMED BY A FACTORY TRAINED AND <br />AUTHORIZED REPRESENTATIVE. <br />C. APPROVED MANUFACTURER (ONE OF THE FOLLOWING, NO SUBSTITUTIONS): <br />1. QMI SECURITY SOLUTIONS (ITASCA IL; 630-529-7111) <br />2. NSBS (800-804-0059) FOR EXTERIOR GRILLS ONLY. <br />D. SHUTTER TYPE: AS INDICATED AND IN ACCORDANCE WITH T-MOBILE NATIONAL ACCOUNT <br />REQUIREMENTS. <br />E. EXAMINATION <br />1. PRIOR TO STARTING WORK, CAREFULLY INSPECT INSTALLED WORK OF OTHER TRADES <br />AND VERIFY THAT SUCH WORK IS COMPLETE TO THE POINT WHERE WORK OF THIS <br />SECTION MAY PROPERLY COMMENCE. NOTIFY THE ARCHITECT IN WRITING OF <br />CONDITIONS DETRIMENTAL TO THE PROPER AND TIMELY COMPLETION OF THE WORK. <br />2. DO NOT BEGIN INSTALLATION UNTIL UNSATISFACTORY CONDITIONS ARE RESOLVED. <br />BEGINNING WORK CONSTITUTES ACCEPTANCE OF SITE CONDITIONS AND <br />RESPONSIBILITY FOR DEFECTIVE INSTALLATION CAUSED BY PRIOR OBSERVABLE <br />CONDITIONS. <br />F. INSTALLATION <br />1. INSTALL SHUTTER AND OPERATING EQUIPMENT COMPLETE WITH ACCESSORIES IN <br />ACCORDANCE APPROVED SHOP DRAWINGS, AND MANUFACTURER'S <br />RECOMMENDATIONS. <br />G. FIELD QUALITY CONTROL <br />1. VERIFY THAT MOVING PARTS OPERATE SMOOTHLY, COILING SHUTTERS ARE FREE <br />FROM WARP, TWISTS, OR DISTORTION, SHUTTERS REMAIN IN REQUIRED POSITION, AND <br />SAFETY FEATURES FUNCTION PROPERLY. <br />2. REPAIR DAMAGE TO OVERHEAD COILING SHUTTERS TO MATCH MANUFACTURER'S <br />ORIGINAL FINISH. REPLACE COMPONENTS WHICH CANNOT BE PROPERLY REPAIRED. <br />3. ADJUST MECHANISM SO MOVING PARTS OPERATE SMOOTHLY. <br />H. COLOR <br />1. PROVIDE ANODIZED ALUMINUM FINISH, REGARDLESS OF STOREFRONT WINDOW <br />COLOR. <br />084113 ALUMINUM -FRAMED ENTRANCES AND STOREFRONTS <br />A. SUMMARY: <br />1. EXTERIOR ALUMINUM FRAMED STOREFRONT AND WINDOW SYSTEMS. <br />2. INTERIOR ALUMINUM FRAMED STOREFRONT SYSTEMS. <br />3. ALUMINUM FRAMED GLASS DOORS. <br />B. REFERENCES: <br />1. AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM): <br />2. B209 - ALUMINUM AND ALUMINUM ALLOY SHEET AND PLATE. <br />3. B221 - ALUMINUM ALLOY EXTRUDED BARS, RODS, WIRE, SHAPES, AND TUBES. <br />4. E283 - RATE OF AIR LEAKAGE THROUGH EXTERIOR WINDOWS, CURTAIN WALLS, AND <br />DOORS. <br />5. E330 - STRUCTURAL PERFORMANCE OF EXTERIOR WINDOWS, CURTAIN WALLS, AND <br />DOORS BY UNIFORM STATIC AIR PRESSURE DIFFERENCE. <br />r <br />DI1l1S COP NIN C NT SUN � E GS, U <br />6. ARCHITECTURAL ALUMINUM MANUFACTURER'S ASSOCIATION (AAMA). <br />C. SYSTEM DESCRIPTION: <br />1. PERFORMANCE - EXTERIOR ALUMINUM WINDOW AND STOREFRONT SYSTEM: <br />a. SYSTEM SHALL ACCOMMODATE EXPANSION AND CONTRACTION CAUSED BY A <br />TEMPERATURE RANGE OF 20 DEGREES TO 140 DEGREES F. WITHOUT DETRIMENTAL <br />EFFECTS TO COMPONENTS, SEALING SYSTEMS, AND SURROUNDING CONSTRUCTION. <br />b. DESIGN SYSTEM WITH PROVISIONS TO DRAIN MOISTURE TO THE EXTERIOR OF THE <br />SYSTEM. <br />c. AIR INFILTRATION: SHALL NOT EXCEED .05 CFM PER SQUARE FOOT OF FIXED AREA <br />WHEN TESTED IN ACCORDANCE WITH ASTM E 283, <br />d. WATER INFILTRATION: NO WATER PENETRATION AT A TEST PRESSURE OF 6.24-LB/SQ <br />FT. WHEN MEASURED IN ACCORDANCE WITH ASTM E 331. <br />2. WINDOW AND STOREFRONT STRUCTURAL DESIGN: <br />a. DESIGN AND SIZE MEMBERS TO WITHSTAND POSITIVE AND NEGATIVE WIND LOADS AS <br />REQUIRED BY THE CURRENTLY ENFORCED EDITION OF THE BUILDING CODE. <br />b. LIMIT MULLION DEFLECTION TO 1/175, OR FLEXURE LIMIT OF GLASS WITH FULL <br />RECOVERY OF GLAZING MATERIALS, WHICHEVER IS LESS. <br />D. WARRANTY: FURNISH FIVE YEAR WRITTEN WARRANTY EXECUTED TO T-MOBILE, FROM THE <br />MANUFACTURER OF THE STOREFRONT SYSTEM, AGAINST DEFECTS IN MATERIALS AND <br />WORKMANSHIP, IN ACCORDANCE WITH DIVISION 1. <br />E. MATERIALS: <br />1. EXTRUDED ALUMINUM: ASTM B 221; 6063 T5 ALLOY AND TEMPER. <br />2. SHEET ALUMINUM: ASTM B 209; 5005-H32 ALLOY, OR APPROVED. <br />F. COMPONENTS: <br />1. EXTERIOR STOREFRONT AND WINDOW FRAMING: <br />a. PARTIAL REPLACEMENT: WHERE NEW ENTRANCE OR FRAMING IS INDICATED TO BE <br />INSTALLED ALONG WITH EXISTING TO REMAIN, MATCH DIMENSIONS, PROFILE, GLAZING <br />THICKNESS AND FINISH OF EXISTING ALUMINUM WINDOW FRAMING INDICATED TO <br />REMAIN. <br />b. WHERE STOREFRONT SYSTEM AS INDICATED ON THE DRAWINGS IS NEW, PROVIDE <br />MANUFACTURER'S STANDARD NOMINAL 2" X 4" CENTER -GLAZED THERMALLY BROKEN <br />STOREFRONT FRAMING SYSTEM. <br />2. INTERIOR (MALL) STOREFRONT AND WINDOW FRAMING: MANUFACTURER'S STANDARD <br />NOMINAL 2" X 4" CENTER -GLAZED NON -THERMALLY BROKEN STOREFRONT FRAMING <br />SYSTEM. <br />3. ACCEPTABLE MANUFACTURERS: KAWNEER, YKK, EFCO, ARCADIA. UNLESS OTHERWISE <br />SPECIFIED <br />4. DOORS: EXTRUDED ALUMINUM FRAME; MEDIUM STILE; PROVIDE WITH SPECIAL 10 INCH <br />HIGH BOTTOM RAIL. <br />5. DOOR HARDWARE: <br />a. PROVIDE MANUFACTURER'S STANDARD OFFSET PIVOT HINGES, UNLESS INDICATED <br />OTHERWISE ON THE DRAWINGS. <br />b. MANUFACTURER'S STANDARD WEATHERSTRIPPING, INCLUDING BOTTOM SWEEP. <br />c. BALANCE OF HARDWARE IS LISTED ON THE DRAWINGS. <br />d. GLAZING BEADS: MANUFACTURER'S STANDARD EPDM OR NEOPRENE GLAZING BEADS, <br />FOR A COMPLETE WEATHERPROOF SEAL. FURNISH FOR INSTALLATION AS A PART OF <br />THE WORK OF SECTION 088000. <br />G. FABRICATION: <br />1. FABRICATE FRAMES ALLOWING FOR SHIM SPACING AROUND PERIMETER OF ASSEMBLY, <br />YET ENABLING INSTALLATION. <br />2. RIGIDLY FIT JOINTS AND CORNERS. ACCURATELY FIT AND SECURE CORNERS TIGHT. <br />MAKE CORNER JOINTS FLUSH, HAIRLINE, AND WEATHERPROOF. SEAL JOINTS WITH <br />SEALANT. <br />3. PROVIDE DRAINAGE HOLES TO ALLOW WATER TO FLOW TO EXTERIOR. <br />4. PREPARE COMPONENTS TO RECEIVE ANCHORAGE DEVICES. FABRICATE ANCHORAGE <br />ITEMS. <br />5. PROVIDE INTERNAL REINFORCEMENT IN MULLIONS WITH MEMBERS TO MAINTAIN <br />RIGIDITY. PROVIDE REINFORCING AT ALL DOOR STRIKE JAMBS. <br />6. FABRICATE STOREFRONT SYSTEM TO ACCOMMODATE HARDWARE USING TEMPLATES <br />FURNISHED FROM SECTION 087100. <br />7. FABRICATE CUSTOM EXTRUSIONS, CLOSURES, AND SHEET MATERIALS TO THE SHAPES <br />INDICATED; FABRICATE FOR ATTACHMENT WITH CONCEALED FASTENERS TO THE <br />GREATEST POSSIBLE EXTENT. <br />H. FINISH: <br />1. ANODIZED FINISH: MANUFACTURER'S STANDARD ANODIZED FINISH; .7 MIL MINIMUM <br />THICKNESS; CLEAR, UNLESS INDICATED OTHERWISE ON THE DRAWINGS. PROVIDE AT <br />ALL EXPOSED ALUMINUM SURFACES. <br />I. INSTALLATION: <br />1. INSTALL FRAMES, DOORS, AND HARDWARE IN ACCORDANCE WITH MANUFACTURER'S <br />INSTRUCTIONS. <br />2. USE ANCHORAGE DEVICES TO SECURELY ATTACH FRAME TO STRUCTURE. <br />3. ALIGN FRAMES PLUMB AND LEVEL, FREE OF WARP OR TWIST. MAINTAIN DIMENSIONAL <br />TOLERANCES, ALIGNING WITH ADJACENT WORK. <br />4. INSTALL ALUMINUM FLASHINGS AT HEAD AND SILL. FINISH TO MATCH STOREFRONT AND <br />WINDOWS. <br />5. PERIMETER SEALANT IS PROVIDED UNDER SECTION 079200. <br />6. ADJUST HARDWARE INSTALLED IN THIS SECTION FOR SMOOTH OPERATION. <br />7. PROTECT ALUMINUM FROM DISSIMILAR MATERIAL WITH A COATING OF BITUMINOUS <br />S U <br />PAINT, A MINIMUM 1-MIL THICKNESS OF ZINC CHROMATE PRIMER, PLASTIC SEPARATOR <br />MATERIALS, OR ISOLATION TAPE. KEEP ISOLATION MATERIALS UNEXPOSED TO VIEW. <br />087100 DOOR HARDWARE <br />A. SUPPLIER: FINISH HARDWARE SHALL BE SUPPLIED BY RECOGNIZED BUILDERS' HARDWARE <br />SUPPLIER WHO HAS BEEN FURNISHING HARDWARE IN THE SAME AREA AS THE PROJECT <br />FOR A PERIOD OF NOT LESS THAN TWO YEARS. THE SUPPLIER'S ORGANIZATION SHALL <br />INCLUDE A MEMBER OF THE AMERICAN SOCIETY OF ARCHITECTURAL HARDWARE <br />CONSULTANTS WHO IS AVAILABLE AT ALL REASONABLE TIMES DURING THE COURSE OF THE <br />WORK TO MEET WITH T-MOBILE, ARCHITECT OR CONTRACTOR FOR PROJECT HARDWARE <br />CONSULTATION. <br />B. INSTALLER: FINISH HARDWARE SHALL BE INSTALLED ONLY BY EXPERIENCED TRADESMEN IN <br />COMPLIANCE WITH TRADE UNION JURISDICTIONS, EITHER AT THE DOOR AND FRAME <br />FABRICATION PLANT OR AT THE PROJECT SITE. <br />C. CODES: <br />1. ALL FINISH HARDWARE SHALL COMPLY WITH APPLICABLE LOCAL AND/OR STATE <br />CURRENT BUILDING CODES. <br />2. HARDWARE FOR FIRE -RATED OPENINGS SHALL ALSO BE IN COMPLIANCE WITH ALL FIRE <br />BUILDING CODES APPLICABLE TO THE DISTRICT IN WHICH THE BUILDING IS LOCATED. <br />PROVIDE ONLY HARDWARE WHICH HAS BEEN TESTED AND LISTED BY UL FOR THE <br />TYPES AND SIZES OF DOORS REQUIRED, AND WHICH COMPLIES WITH THE <br />REQUIREMENTS OF THE DOOR AND DOORFRAME LABELS. <br />3. PROVIDE SMOKE SEALS AS REQUIRED AT EACH FIRE -RATED OPENING. <br />D. DELIVERY: DELIVER ALL HARDWARE IN MANUFACTURERS' ORIGINAL UNOPENED <br />UNDAMAGED PACKAGES, CLEARLY IDENTIFYING MANUFACTURER, BRAND NAME, AND <br />CONTENTS. <br />E. IN ADDITION TO REQUIRED ONE YEAR WARRANTY UNDER CONDITIONS OF THE CONTRACT, <br />FURNISH 5-YEAR UNCONDITIONAL GUARANTEES FOR ALL DOOR CLOSERS, UNDER <br />PROVISIONS OF DIVISION 1. <br />F. FACTORY REPRESENTATIVES FOR DOOR CLOSERS, EXIT BOLTS, AND LOCKSETS SHALL BE <br />AVAILABLE DURING THE CONSTRUCTION TO INSTRUCT THE CONTRACTOR ON THE PROPER <br />METHOD OF INSTALLATION OF THEIR MATERIALS. THEY SHALL INSPECT AND ADJUST THEIR <br />MATERIALS AT THE COMPLETION OF THE WORK, AND SUPPLY PROPER MAINTENANCE <br />MANUALS TO T-MOBILE. <br />G. FURNISH 2 SETS OF SPECIAL TOOLS FOR INSTALLATION AND MAINTENANCE OF HARDWARE. <br />TOOLS FOR MAINTENANCE AND ADJUSTMENTS ARE TO BE DELIVERED TO T-MOBILE UPON <br />COMPLETION OF THE WORK. <br />H. IN GENERAL, UNLESS OTHERWISE INDICATED, FINISHES SHALL BE SATIN CHROME US26D. <br />I. GENERAL: CONSTRUCTION MASTERKEY ALL LOCKSETS AND CYLINDER ITEMS; PROVIDE 6 <br />CONSTRUCTION MASTERKEYS. <br />J. KEYING: CONTRACTOR SHALL BE RESPONSIBLE FOR FINAL KEYING, AS FOLLOWS: <br />1. CONSULT WITH T-MOBILE'S AUTHORIZED REPRESENTATIVE AND PREPARE DETAILED <br />KEYING SCHEDULE ACCORDINGLY. T-MOBILE'S REPRESENTATIVE WILL COORDINATE <br />KEYING REQUIREMENTS WITH AUTHORIZED REPRESENTATIVE OF HARDWARE SUPPLIER. <br />2. STAMP "DO NOT DUPLICATE" ON ALL KEYS. <br />K. BUTTS: <br />1. IN THE FOLLOWING PARAGRAPHS WHERE HAGER NUMBERS ARE LISTED, EQUIVALENT <br />ITEMS OF LAWRENCE, MCKINNEY SALES COMPANY, OR THE STANLEY WORKS MAY BE <br />SUPPLIED. <br />2. EXTERIOR DOORS (OUTSWING) 38" WIDE OR LESS SHALL HAVE HAGER BB1191 BUTTS, <br />SIZE 4 1/2 X 4 1/2. <br />3. INTERIOR DOORS 38" WIDE OR LESS SHALL HAVE HAGER BB1279 BUTTS, SIZE 4 1/2 X 4 <br />1/2. <br />4. PROVIDE BUTTS ON EXTERIOR DOORS WITH NON -REMOVABLE PINS (SET SCREW IN <br />BARREL, PIN NON -REMOVABLE WHEN DOOR IS CLOSED), AND SAFETY STUD. <br />5. PROVIDE FULL THREADED WOOD SCREWS FOR WOOD DOORS AND/OR JAMBS. <br />6. BUTT WIDTHS LISTED ARE MINIMUM. PROVIDE BUTTS OF WIDER THROW TO SUITE <br />CONDITIONS FOR 180° OPERATION OF DOORS, STRUCTURAL CONDITIONS PERMITTING. <br />D,1.ISION $ - OPENINGSI CUNT, - <br />L. LOCKSETS, DEADLOCKS, CYLINDERS AND PADLOCKS: <br />1. MANUFACTURER: <br />A. LOCKS AND DEADLOCKS - AS NOTED IN HARDWARE SCHEDULE ON DRAWINGS <br />B. CYLINDERS AND PADLOCKS - AS NOTED IN HARDWARE SCHEDULE ON DRAWINGS <br />2. PROVIDE NEW CYLINDER AT EACH EXISTING DOOR THAT HAS DEADLOCK OR LOCKSET. <br />3. PROVIDE LOCK STRIKES WITH MINIMUM PROJECTION TO PROTECT TRIM. <br />4. PROVIDE WROUGHT BOXES FOR LOCKSETS AND DEADLOCKS. <br />5. PROVIDE DEADLOCKS WITH ARMORED FRONTS. <br />6. FUNCTION AS INDICATED IN HARDWARE GROUPS. <br />7. DEAD BOLTS AT EXTERIOR DOORS SHALL HAVE A MINIMUM THROW OF 1 INCH AND <br />MINIMUM EMBEDMENT OF % INCH. <br />8. TYPES: AS INDICATED ON THE DRAWINGS. <br />M. ELECTRONIC HARDWARE <br />1. TYPES: AS INDICATED ON THE DRAWINGS. <br />N. DOOR CLOSERS: <br />1. MANUFACTURERS: <br />a. OVERHEAD CLOSERS: LCN OR RIXSON. <br />b. FLOOR CLOSERS: LCN OR RIXSON. <br />2. ALL OVERHEAD CLOSERS TO BE MOUNTED ON INTERIOR SIDE OF DOOR. NO THRU <br />BOLTS. <br />3. PROVIDE MOUNTING BRACKETS AND PROPER LENGTH ARMS TO SUIT ALL CONDITIONS. <br />PROVIDE ARM OPTIONS AS SCHEDULED OR RECOMMENDED BY MANUFACTURER. <br />FINISH SHALL MATCH LOCKSETS <br />4. SIZES SHALL BE AS RECOMMENDED BY THE MANUFACTURER. CLOSERS SHALL HAVE A <br />5-YEAR UNCONDITIONAL GUARANTEE. <br />5. PROVIDE STANDARD FULL COVERS AT OVERHEAD CLOSERS; FINISH TO MATCH ARMS, <br />UNLESS OTHERWISE INDICATED. <br />6. CLOSURE PRESSURE: SET TO 5 POUNDS FOR BOTH EXTERIOR AND INTERIOR DOORS, <br />PER CURRENT REQUIREMENTS OF THE AMERICANS WITH DISABILITIES ACT, UNLESS <br />REQUIRED OTHERWISE BY LOCAL JURISDICTIONAL AUTHORITIES. <br />7. TYPES: AS INDICATED ON THE DRAWINGS. <br />0. DOOR STOPS AND OVERHEAD STOPS: AS SCHEDULED. <br />1. LOCATE FLOOR STOPS FREE FROM FOOT TRAFFIC. <br />2. TYPES: AS INDICATED ON THE DRAWINGS. <br />P. PUSH/PULL BARS AND SETS: <br />1. TYPES: AS INDICATED ON THE DRAWINGS. <br />Q. WEATHERSTRIP, THRESHOLDS, DOOR BOTTOM AND GASKETS: <br />1. MANUFACTURER: PEMKO MFG. CO., OR APPROVED EQUAL BY RIXSON. <br />2. TYPES: AS INDICATED ON THE DRAWINGS. <br />R. MISCELLANEOUS: <br />1. PROVIDE SILENCERS FOR ALL DOORJAMBS, 3 FOR SINGLE JAMBS AND 4 FOR DOUBLE <br />JAMBS. <br />2. TYPES: AS INDICATED ON THE DRAWINGS. <br />S. FURNISH FOR EACH DOOR THE ITEMS SCHEDULED WITHIN THE DESIGNATED HARDWARE <br />GROUPS AS SHOWN ON THE DRAWINGS. <br />T. ADJUSTMENTS AND TESTING: <br />1. ADJUST AND CHECK EACH OPERATING ITEM OF HARDWARE AND EACH DOOR TO <br />ENSURE PROPER OPERATION OF FUNCTION OF EVERY UNIT, <br />2. LUBRICATE MOVING PARTS WITH GRAPHITE TYPE LUBRICANT UNLESS OTHERWISE <br />RECOMMENDED BY THE HARDWARE MANUFACTURER. <br />3. REPLACE UNITS WHICH CANNOT BE ADJUSTED AND LUBRICATED TO OPERATE FREELY <br />AND SMOOTHLY AS INTENDED FOR THE APPLICATION MADE. <br />4. ADJUST CLOSER PRESSURES AS SPECIFIED IN SECTION 087100, UNLESS OTHERWISE <br />REQUIRED BY JURISDICTIONAL AUTHORITIES. <br />5. TESTING: <br />a. TEST CLOSER FOR COMPLIANCE WITH REQUIREMENTS OF SECTION 087100, INCLUDING <br />OPENING FORCE AND CLOSING SPEED REQUIRED BY JURISDICTIONAL AUTHORITIES. <br />b. PROVIDE TESTING DEVICE, OPERATE TEST AT EACH DOOR, AND PROVIDE A WRITTEN <br />REPORT ON RESULTS OF TESTS. <br />c. TESTING DEVICE SHALL REMAIN IN THE POSSESSION OF T-MOBILE. <br />087300 DOOR AND HARDWARE INSTALLATION <br />A. QUALITY ASSURANCE: INSTALLERS OF DOORS AND FINISH HARDWARE SHALL BE SKILLED <br />MECHANICS REGULARLY EMPLOYED IN THE DOOR HARDWARE INDUSTRY AND <br />EXPERIENCED IN THE INSTALLATION OF DOORS AND DOOR HARDWARE. <br />B. DOORS, FRAMES, AND HARDWARE: SPECIFIED IN OTHER SECTIONS. <br />C. DOOR AND HARDWARE INSTALLATION <br />1. FIT AND PREPARE DOORS FOR INSTALLATION IN ACCORDANCE WITH THE DOOR <br />MANUFACTURER'S PRINTED INSTRUCTIONS. <br />2. INSTALL DOORS PLUMB AND SQUARE. <br />3. PROVIDE CLEARANCES OF 1/8 INCH AT JAMBS AND HEADS, 1/8 INCH AT MEETING STILES <br />FOR PAIRS OF DOORS, AND 1/2 INCH FROM BOTTOM OF DOOR TO TOP OF DECORATIVE <br />FLOOR FINISH OR COVERING, EXCEPT WHERE THRESHOLD IS SHOWN OR SCHEDULED <br />PROVIDE 1/4-INCH CLEARANCE FROM BOTTOM OF DOOR TO TOP OF THRESHOLD. <br />4. INSTALL ROSES, KICK PLATES, CLOSERS, AND OTHER SURFACE MOUNTED HARDWARE <br />ONLY AFTER DOOR FINISHING IS COMPLETE AND FINISHES ARE COMPLETELY CURED. <br />5. FIT HOLLOW METAL DOORS IN ACCORDANCE WITH SDI 100. <br />6. FINISH HARDWARE INSTALLATION <br />a. INSTALLER SHALL RECEIVE DELIVERY AND UNPACK, TAG, INDEX, AND FILE ALL KEYS. KEEP <br />HARDWARE IN A SEPARATE ROOM UNDER LOCK AND KEY AT THE SITE UNTIL <br />INSTALLATION IS MADE. <br />b. VERIFY ALL DIMENSIONS AND BE RESPONSIBLE FOR THE CORRECT INSTALLATION AND FIT <br />OF HARDWARE AT THE LOCATIONS INDICATED ON THE DRAWINGS AND AS SPECIFIED. <br />c. INSTALL EACH HARDWARE ITEM IN COMPLIANCE WITH THE MANUFACTURER'S <br />INSTRUCTIONS AND RECOMMENDATIONS. <br />d. WHEREVER CUTTING AND FITTING ARE REQUIRED TO INSTALL HARDWARE ONTO OR INTO <br />SURFACES WHICH ARE LATER TO BE PAINTED OR FINISHED IN ANOTHER WAY, INSTALL <br />EACH ITEM COMPLETELY AND THEN REMOVE AND STORE IN A SECURE PLACE DURING <br />THE FINISH APPLICATION. AFTER COMPLETION OF THE FINISHES, REINSTALL EACH ITEM. <br />DO NOT INSTALL SURFACE -MOUNTED ITEMS UNTIL FINISHES HAVE BEEN COMPLETED ON <br />THE SUBSTRATE. <br />e. HARDWARE MOUNTING HEIGHTS: AS INDICATED. WHERE NOT INDICATED, COMPLY WITH <br />RECOMMENDATIONS OF THE NATIONAL BUILDERS HARDWARE ASSOCIATION (NBHA). <br />7. ADJUSTMENT AND CLEANING: ADJUST AND CHECK EACH OPERATING ITEM OF <br />HARDWARE AND EACH DOOR TO ENSURE PROPER OPERATION OF FUNCTION OF EVERY <br />UNIT. LUBRICATE MOVING PARTS WITH GRAPHITE TYPE LUBRICANT UNLESS <br />OTHERWISE RECOMMENDED BY THE HARDWARE MANUFACTURER. REPLACE UNITS <br />WHICH CANNOT BE ADJUSTED AND LUBRICATED TO OPERATE FREELY AND SMOOTHLY <br />AS INTENDED FOR THE APPLICATION MADE. <br />088000 GLAZING <br />A. GLASS: PROVIDE THE FOLLOWING GLASS AS SCHEDULED ON THE DRAWINGS: <br />1. CLEAR GLASS: ASTM C1036, TYPE I, CLASS 1, CLEAR, QUALITY Q3 GLAZING SELECT. <br />B. PLASTIC GLAZING: ACRYLIC PANEL AS SCHEDULED ON THE DRAWINGS. <br />C. ACCESSORIES: <br />1. SILICONE SEALANT: DOW CORNING "795"; CLEAR COLOR. <br />2. SETTING BLOCKS: COMPATIBLE WITH SILICONE SEALANTS; 70-90 SHORE A HARDNESS. <br />3. SPACERS: COMPATIBLE WITH SILICONE SEALANT. <br />4. GLAZING TAPE: TREMCO "CCN" SPONGE, OR APPROVED. <br />5. GLAZING CHANNELS: EXTRUDED ALUMINUM; PROFILE AS INDICATED ON THE <br />DRAWINGS; CLEAR ANODIZED FINISH. <br />D. FABRICATION: <br />1. INSULATING GLASS UNITS: <br />a. DUAL LITE UNITS FABRICATED FROM GLASS AS SCHEDULED; 1/2 INCH NOMINAL AIRSPACE; <br />DUAL SEAL SYSTEM. <br />b. TWIN SEALS; POLYISOBUTYLENE PRIMARY SEAL AND SILICONE SECONDARY SEAL. OUTER <br />SEAL SHALL BE COMPATIBLE WITH GLAZING SYSTEM. <br />c. SPACER BAR: MILL FINISH ALUMINUM; FILL WITH DESICCANT; CORNERS SHALL BE <br />PARTIALLY MITER CUT AND BENT (NOT CUT THROUGH), OR FORMED WITH CORNER KEYS <br />ULTRASONICALLY SOLDERED IN PLACE. <br />d. CERTIFIED THROUGH THE INSULATING GLASS CERTIFICATION COUNCIL (IG.C.C) IN <br />ACCORDANCE WITH ASTM E773 AND E774; CERTIFIED TO LEVEL CBA. <br />e. EACH PIECE SHALL BEAR CERTIFICATION NUMBER, DATE, AND MANUFACTURER'S <br />IDENTIFICATION MARK. <br />2. TEMPERED AND HEAT STRENGTHENED GLASS: <br />a. TEMPERED GLASS: GLASS WHICH HAS BEEN HEAT TREATED TO STRENGTHEN GLASS IN <br />BENDING TO NOT LESS THAN 4 TIMES THE ANNEALED STRENGTH; CERTIFIED SAFETY <br />GLASS IN ACCORDANCE WITH ANSI Z97.1. <br />b. HEAT STRENGTHENED GLASS: ASTM C1048; GLASS WHICH HAS BEEN HEAT TREATED TO <br />STRENGTHEN GLASS IN BENDING TO NOT LESS THAN 2 TIMES ANNEALED STRENGTH. <br />c. FABRICATE TEMPERED AND HEAT STRENGTHENED GLASS UNITS SO THAT PRINCIPLE <br />DISTORTION WILL BE IN THE HORIZONTAL DIRECTION IN THE FINISHED INSTALLATION. <br />d. UNLESS OTHERWISE APPROVED BY THE BUILDING OFFICIAL, PROVIDE MANUFACTURER'S <br />LABEL ON EACH LIGHT, INDICATING TYPE AND THICKNESS OF GLASS. <br />Mobi*le" <br />12920 SE 38th STREET <br />BELLEVUE, WA 98006 <br />www.T-Mobile.com <br />COPYRIGHT NOTICE <br />THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO <br />COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF <br />THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED JANUARY 2003. THE PROTECTION <br />INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND <br />COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH <br />PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS <br />MAY RESULT IN CESSATION OF CONSTRUCTION, BUILDING SEIZURE, AND/OR <br />MONETARY LIABILITY. <br />ARCHITECT <br />rmUzioN <br />9096 EAST BAHIA DRIVE <br />SUITE 103 <br />SCOTTSDALE, AZ 85260 <br />DESIGN@FUZIONVE.COM <br />WWW.FUZIONVE.COM <br />VENDOR PROJECT NO: 21.11.212680 <br />E CF. F <br />OLQU <br />�4 ✓C . <br />ti, <br />�0K 0 4 <br />'SrFR -D A�G�� <br />02/10/2022 <br />CONSULTING ENGINEER: <br />CV <br />W <br />Q <br />Lu <br />Q r <br />Z Q M <br />W > cM <br />o Lu JJ <br />.j 5 <br />O J <br />m � <br />od <br />� J - <br />� J � <br />♦♦a^^ <br />V <br />00 <br />> N W <br />-JN <br />J <br />♦Q <br />V <br />DATE: February 5, 2022 <br />SCALE: AS NOTED <br />DRAWN BY: LEO V. <br />SAP NUMBER: <br />4SIR <br />CORPORATE TENANT REBUILD <br />LDC <br />SHEET TITLE: <br />SPECIFICATIONS <br />SHEET NUMBER: <br />4 <br />3 <br />e <br />1 <br />A703 <br />