4 I 3 I 2 <br />1 <br />0 1 <br />ml <br />QI <br />I li ION p; E 7N 0 l � . � � t� I�II��, '�>, <br />E. COMPLY WITH UBC REQUIREMENTS FOR IDENTIFICATION AND LABELING OF <br />SAFETY -GLAZING MATERIALS IN HAZARDOUS LOCATIONS SUBJECT TO HUMAN IMPACT <br />LOADS. <br />3. GLAZING CLIPS: <br />a. PROVIDE GLAZING CLIPS AS INDICATED IN DRAWINGS <br />b. C.R. LAURENCE CO., INC.: 90 DEGREE; FINISH: POLISHED <br />STAINLESS; PRODUCT: MFC34 - 2" DIA. <br />c. C.R. LAURENCE CO., INC.: 135 DEGREE; FINISH: POLISHED <br />STAINLESS; PRODUCT: MFC38 - 2" DIA. <br />d. C.R. LAURENCE CO., INC.: 180 DEGREE; FINISH: POLISHED <br />STAINLESS; PRODUCT: MFC30 - 2" DIA. <br />F. PREPARATION: <br />1. CLEAN CONTACT SURFACES AND WIPE DRY. <br />2. SEAL FRAME CORNER JOINTS, AND OTHER LEAKAGE POINTS WITH SEALANT. AT <br />INSULATING GLASS UNITS THE SEALANT SHALL BE COMPATIBLE WITH THE SEAL OF THE <br />UNIT. DO NOT PLUG WEEP HOLES. <br />3. PRIME SURFACES SCHEDULED TO RECEIVE SEALANT, UNLESS OTHERWISE <br />RECOMMENDED BY THE SEALANT MANUFACTURER. <br />F. INSTALLATION: <br />1. UNLESS SPECIFIED OTHERWISE, GLAZE IN ACCORDANCE WITH THE CURRENT EDITION <br />OF GLASS ASSOCIATION OF NORTH AMERICA (GANA): GLAZING MANUAL. <br />2. SETTING BLOCKS: PLACE SETTING BLOCKS IN FRAMES FOR SUPPORT OF GLASS. PLACE <br />AT QUARTER POINTS UNLESS APPROVED OTHERWISE. <br />3. SET GLASS TIGHTLY IN POSITION WITH PROPER CLEARANCES IN ACCORDANCE WITH <br />THE REFERENCED STANDARD. <br />4. UNLESS SPECIFIED OTHERWISE, GLAZE UNITS WITH GASKETS FURNISHED WITH THE <br />FRAMING SYSTEMS SPECIFIED IN OTHER SECTIONS. <br />5. GLAZING FOR INTERIOR NON -RATED DOORS AND WINDOWS, WHERE GASKETS ARE NOT <br />FURNISHED: <br />a. GLAZE WITH GLAZING TAPE. <br />b. PRE -MEASURE AND CUT TAPES TO REQUIRED LENGTHS; ADHERE TO FIXED STOPS, <br />SETTING HORIZONTAL TAPE AT HEADS AND SILLS BEFORE VERTICAL TAPE. <br />C. INSTALL TAPE WITH TIGHT BUTT JOINTS; NO OVERLAPS WILL BE ACCEPTED. SET TAPE <br />WITH STRAIGHT LINES LEVEL WITH FRAME SIGHT LINE. <br />d. POSITION GLASS, UNIFORMLY SEALING AGAINST TAPE. INSTALL INSIDE REMOVABLE <br />STOPS AND PLACE TAPE IN STOPS FORMING A UNIFORM SEAL AGAINST GLASS, LEVEL <br />WITH SIGHT LINES. <br />6. GLAZING FOR FIRE RATED DOORS AND WINDOWS: GLAZE IN ACCORDANCE WITH NFPA <br />80, UNLESS REQUIRED OTHERWISE BY THE LABELING REQUIREMENT OF THE FRAME. <br />7. ADJUST GLAZING MATERIALS TO FORM A UNIFORM SIGHT LINE. <br />G.SCHEDULE: <br />1. TYPE 1: CLEAR TEMPERED GLAZING WHERE INDICATED AND SPECIFIED. <br />2. TYPE 2: INSULATING GLASS, DOUBLE GLAZED UNITS WITH 1/2 INCH AIR SPACE BETWEEN <br />TWO PANES OF 1/4 INCH GLASS; OUTER PANE SHALL BE TINTED HEAT STRENGTHENED <br />OR TEMPERED GLASS; INNER PANE SHALL BE CLEAR GLASS. <br />3. PROVIDE TEMPERED WHERE INDICATED AND SPECIFIED. WHERE NOT REQUIRED BY <br />CODE TO BE TEMPERED, PROVIDE ANNEALED, HEAT -STRENGTHENED OR TEMPERED <br />GLASS AS DETERMINED BY GLASS MANUFACTURER'S GLASS ANALYSIS. <br />H. PROVIDE TEMPERED GLASS IN HAZARDOUS LOCATIONS TO MEET THE REQUIREMENTS <br />OF THE JURISDICTIONAL CODE AUTHORITIES. <br />DIV1*ION f �� - FIIVI IH S <br />090561.13 MOISTURE VAPOR EMISSIONG CONTROL <br />A.GENERAL: PRE -FORMED MOISTURE SUPPRESSION MEMBRANE INSTALLED OVER <br />CONCRETE SUBFLOOR AS A FLOOR COVERING UNDERLAYMENT. <br />B. REFERENCES: <br />1. D3273-00- STANDARD TEST METHOD FOR RESISTANCE TO GROWTH OF MOLD ON THE <br />SURFACE OF INTERIOR COATINGS IN AN ENVIRONMENTAL CHAMBER <br />2. E-96-05 - STANDARD TEST METHODS FOR WATER VAPOR TRANSMISSION OF MATERIALS <br />3. F 2170 - STANDARD TEST METHOD FOR DETERMINING RELATIVE HUMIDITY IN <br />CONCRETE FLOOR SLABS USING IN SITU PROBES <br />C.SUBMITTALS: <br />1. MANUFACTURER'S CURRENT INSTALLATION INSTRUCTIONS <br />2. MANUFACTURER'S WARRANTY REGISTRATION WITH CONCRETE SUBFLOOR MOISTURE <br />TEST RESULTS AND BUILDING AMBIENT AIR TEMPERATURE AND RELATIVE HUMIDITY <br />TEST RESULTS. <br />SECTION 0 D. COORDINATION: COORDINATE THIS F WORK AND DIRECTLY RELATED <br />O <br />SECTION S WITH CONCRETE FLOOR CONSTRUCTION AND REPAIR AND FINISH <br />FLOORING WORK. <br />E. MATERIALS <br />1. MANUFACTURER: HALEX CORPORATION; VERSASHIELD. WWW.HALEXCORP.COM <br />(800)576-1636 <br />2. PRODUCT NAME: VERSASHIELD 95 FLOORING UNDERLAYMENT <br />LY 4-PLY COMPOSITE PRODUCT, a. MATERIAL: FREE-STANDING, DIMENSIONAL STABLE, 4 P GO SI O , <br />ENGINEERED AS A MOISTURE SUPPRESSION MEMBRANE TO BE USED ON CONCRETE <br />FLOORS WHERE HIGH MOISTURE EXISTS. <br />b. DIMENSIONS: [144 FT LONG BY 5 FT WIDE] STANDARD ROLL. <br />c. MOLD, MILDEW & FUNGAL RESISTANCE, ASTM D3273: 10 RATING <br />d. MOISTURE VAPOR TRANSMISSION RATE, ASTM E96-05: LESS THAN 0.01 G/HR/ SQ M <br />e. NO SUBSTITUTIONS PERMITTED <br />3. PRODUCT NAME: VERSASHIELD MBX FLOORING UNDERLAYMENT <br />a. MATERIAL: FREE-STANDING, DIMENSIONALLY STABLE, 4-PLY COMPOSITE PRODUCT, <br />ENGINEERED AS A MOISTURE SUPPRESSION MEMBRANE TO BE USED ON CONCRETE <br />FLOORS WHERE HIGH MOISTURE EXISTS. <br />b. DIMENSIONS: [144 FT LONG BY 5 FT WIDE] STANDARD ROLL. <br />c. MOLD, MILDEW & FUNGAL RESISTANCE, ASTM D3273: 10 RATING <br />d. MOISTURE VAPOR TRANSMISSION RATE, ASTM E96-05: LESS THAN 0.01 G/HR/ SQ M <br />e. NO SUBSTITUTIONS PERMITTED <br />4. ACCESSORIES: VERSASHIELD TAPE <br />a. APPLICATION: JOINING OF MOISTURE SUPPRESSION UNDERLAYMENT SEAMS <br />b. DESCRIPTION: MEMBRANE MANUFACTURER'S MOISTURE SUPPRESSION TAPE WITH <br />PRESSURE SENSITIVE ADHESIVE. <br />F. EXAMINATION <br />1. REFERENCE: SECTION 017000: VERIFY EXISTING CONDITIONS BEFORE STARTING <br />WORK. <br />2. VERIFY THAT SUB -FLOOR SURFACES ARE SMOOTH AND FLAT WITHIN TOLERANCES <br />SPECIFIED FOR THE TYPE OF WORK AND ARE READY TO RECEIVE FLOORING. <br />3. VERIFY THAT SUB -FLOOR IS PREPARED PER ASTM 710. REMOVE COATINGS, INCLUDING <br />CURING COMPOUNDS, AND OTHER SUBSTANCES THAT ARE INCOMPATIBLE WITH <br />ADHESIVES AND THAT CONTAIN SOAP, WAX, OILS, OR SILICONE, WITHOUT USING <br />SOLVENTS. DO NO INSTALL FLOORING IF ALKALINITY EXCEEDS 9 PH. <br />4. VERIFY SUB -FLOOR MOISTURE TEST RESULTS BY CONDUCT RELATIVE HUMIDITY PER <br />ASTM F2170. DO NOT INSTALL FLOORING IS RH EXCEED 75% RELATIVE HUMIDITY. <br />REPORT MOISTURE TEST RESULTS TO ARCHITECT PRIOR TO FLOOR INSTALLATION. <br />a. IF SUB -FLOOR TEST RESULTS EXCEED 75% RELATIVE HUMIDITY AND 9 PH, PROVIDE AND <br />INSTALL MOISTURE MITIGATION SYSTEM, VERSASHIELD 95 UP TO 95% RELATIVE HUMIDITY <br />OR VERSASHIELD MBX UP TO 99% RELATIVE HUMIDITY. <br />b. DO NOT INSTALL IF RH WITHIN THE CONCRETE EXCEEDS 99% <br />G. INSTALLATION <br />1. INSTALL MOISTURE SUPPRESSION MEMBRANE WITH SMOOTH FILM SIDE FACING <br />CONCRETE SLAB. <br />2. INSTALL IN ACCORDANCE WITH MEMBRANE MANUFACTURER'S CURRENT WRITTEN <br />INSTALLATION INSTRUCTIONS. <br />3. IF ANY JOBSITE CONDITION INTERFERES WITH COMPLIANCE WITH MANUFACTURER'S <br />INSTRUCTIONS, CONTACT MANUFACTURER AND OBTAIN WRITTEN JOB -SPECIFIC <br />PROCEDURES. NOTIFY ARCHITECT OR T-MOBILE'S REPRESENTATIVE AS REQUIRED. <br />4. ADHESIVES - APPLY ADHESIVE TO MINERAL -COATED SURFACE OF MOISTURE <br />SUPPRESSION MEMBRANE. USE ONLY WATER -BASED ADHESIVES. DO NOT USE <br />SOLVENT -BASED ADHESIVES. <br />5. PROTECTION - PROTECT MOISTURE SUPPRESSION MEMBRANE FROM DAMAGE DURING <br />FLOORING INSTALLATION. DO NOT TEAR, RIP, PUNCTURE, OR DELAMINATE MEMBRANE <br />WHEN APPLYING TROWEL -ON ADHESIVE. REPAIR DAMAGED AREAS ACCORDING TO <br />MEMBRANE MANUFACTURER'S INSTRUCTIONS BEFORE FLOORING INSTALLATION. <br />PROVIDE CONTINUOUS, INTACT MOISTURE SUPPRESSION MEMBRANE UNDER ENTIRE <br />DESIGNATED FLOORING AREA. <br />6. INSTALL FLOORING ACCORDING TO FLOORING MANUFACTURER'S INSTRUCTIONS <br />DI �iI�JN # C�►I'� <br />092200 LIGHT GAGE METAL SUPPORT FRAMING <br />A. SUMMARY: INTERIOR PARTITION, CEILING, AND SOFFIT CONSTRUCTION, NOT COVERED BY <br />SECTION 054000. <br />B. SYSTEM DESCRIPTION: <br />1. STRUCTURAL DESIGN: <br />a. SELECT FRAMING SYSTEMS, GAGES, SUPPORTS, BRACING, AND CONNECTIONS AS <br />NECESSARY TO MEET THE STRUCTURAL REQUIREMENTS SPECIFIED. <br />b. PARTITION FRAMING SHALL CONFORM TO THE WIDTHS INDICATED, UNLESS APPROVED <br />OTHERWISE. PROVIDE THICKER GAGES AND DECREASED STUD SPACING AS NECESSARY <br />TO MEET THE DESIGN REQUIREMENTS. <br />2. DESIGN LOADS: <br />a. INTERIOR CEILING ASSEMBLIES: 5 POUNDS PER SQUARE FOOT UNIFORM LIVE LOAD, PLUS <br />DEAD LOADS. <br />b. INTERIOR PARTITIONS: 5 POUNDS PER SQUARE FOOT UNIFORM LIVE LATERAL LOAD. <br />c. EXTERIOR SOFFITS: 25 POUNDS PER SQUARE FOOT UNIFORM LIVE LOAD. <br />3. DEFLECTION REQUIREMENTS: MAXIMUM OF 1/240 THE SPAN, EXCEPT MAXIMUM 1/360 AT <br />TILE. <br />C. CODE REQUIREMENTS: <br />1. PROVIDE ASSEMBLIES MEETING THE HOURLY FIRE RATINGS INDICATED AND <br />SPECIFIED. ASSEMBLIES SHALL BEEN TESTED IN ACCORDANCE WITH ASTM E119, AND <br />SHALL BE APPROVED BY THE LOCAL JURISDICTIONAL CODE AUTHORITIES. <br />2. COORDINATE INSTALLATION OF OTHER MATERIALS WHICH ARE A PART EACH <br />ASSEMBLY. <br />3. FIRE RATING REQUIREMENTS TAKE PRECEDENCE OVER THE CONSTRUCTION <br />REQUIREMENTS INDICATED. IN THE EVENT OF CONFLICT, NOTIFY THE ARCHITECT, AND <br />DO NOT BEGIN CONSTRUCTION IN THE AREA OF CONFLICT UNTIL THE CONFLICT HAS <br />BEEN RESOLVED. <br />4. PROVIDE ALL CALCULATIONS, DRAWINGS, PRODUCT DATA, AND OTHER VERIFICATION <br />AS REQUIRED BY THE JURISDICTIONAL CODE AUTHORITY TO OBTAIN APPROVAL OF THE <br />LIGHT GAGE METAL FRAMING INSTALLATION. <br />D. MATERIALS: <br />1. LIGHT GAGE METAL FRAMING: ASTM C645; GALVANIZED; PROVIDE "C" SHAPED STUDS, U <br />SHAPED RUNNERS, HAT AND "Z" SHAPED FURRING CHANNELS, AND OTHER SIZES AND <br />SHAPES AS NECESSARY. MINIMUM 25 GAGE, EXCEPT FURNISH THICKER GAGES AS <br />REQUIRED TO MEET DEFLECTION REQUIREMENTS. <br />2. COLD ROLLED CHANNELS: RUST INHIBITIVE PAINT COATING; SIZES IN ACCORDANCE <br />WITH ASTM C754. <br />3. SCREWS: SELF -TAPPING; LOW PROFILE HEAD. <br />4. SECURITY MESH: AMICO (ALABAMA METAL INDUSTRIES CORP) BIRMINGHAM AL <br />(800/366-2642); ASM .50-13F, MINIMUM 13 GAGE, UNLESS APPROVED OTHERWISE. <br />5. PROPRIETARY CEILING SUSPENSION SYSTEM: <br />A. MANUFACTURER: <br />I. AS SPECIFIED: ARMSTRONG (800-207-2321). <br />11. ACCEPTABLE SUBSTITUTIONS: <br />III. USG INTERIORS, INC. (CHICAGO, IL; 800-874-4968). <br />IV. CHICAGO METALLIC (CHICAGO, IL LOS ANGELES, CA; 800-323-7164). <br />B. SUSPENSION SYSTEM: SIMILAR TO SYSTEM 650, OR 670; ASTM C635 HEAVY DUTY <br />CLASSIFICATION. <br />I. FURRING RUNNERS: MANUFACTURED FROM 0.020 INCH THICK STEEL 1-3/8 INCH WIDE WITH <br />KNURLED FACE BY 1-1/2 INCHES HIGH; FACTORY PUNCHED CROSS TEE SLOTS, HANGER <br />HOLES, AND NON -DIRECTIONAL BAYONET END TAB COUPLINGS. <br />11. FURRING TEES: MANUFACTURED FROM 0.020 INCH THICK L-3/8 INCH WIDE WITH KNURLED <br />FACE BY 1-1/2 INCHES HIGH; FACTORY PUNCHED CROSS TEE SLOTS AND HANGER HOLES. <br />111. FURRING CROSS CHANNEL: 0.020 INCH THICK STEEL; 1-3/8 INCH WIDE WITH KNURLED FACE <br />BY 7/8 INCHES HIGH BY 48 INCHES LONG WITH STRAIGHT LOCKING END TABS. <br />IV. CROSS TEES: 0.020 INCH THICK STEEL 15/16 INCH WIDE BY 1-1/2 INCHES HIGH; WITH <br />STAKED -ON DIP END TAB COUPLINGS, FACTORY PUNCHED CROSS TEE SLOTS. <br />V. MOLDINGS: MANUFACTURER'S STANDARD. <br />6. PARTITION HEAD COMPENSATING CHANNEL (NON -RATED): DESIGN FOR <br />MINIMUM +/- 1/2" DEFLECTION. PROFILES AS INDICATED; ONE OF THE FOLLOWING: <br />a. 20 GAGE DEEP LEG TRACK; 2 INCH LEGS. <br />b. SLIP TRACK SYSTEMS INC. (ANAHEIM, CA; 714-761-1921) "SLP-TRK." <br />7. OTHER FRAMING MATERIALS: FURNISH IN ACCORDANCE WITH ASTM C 754. <br />E. PARTITION FRAMING: <br />1. RUNNERS: <br />a. SECURE RUNNERS WITH FASTENERS AT MAXIMUM 24 INCHES OC. <br />b. AT CONCRETE FLOORS, USE POWDER DRIVEN FASTENERS OR DRILLED IN CONCRETE <br />ANCHORS. <br />c. TOP RUNNER: USE PROPRIETARY COMPENSATING CHANNEL OR DEEP LEG TRACK AT <br />CONTRACTOR'S OPTION, AS NECESSARY TO ACCOMMODATE BUILDING DEFLECTION. <br />d. ALIGN TO TOLERANCES SPECIFIED. <br />2. UNLESS INDICATED OTHERWISE, INSTALL STUDS VERTICALLY AT 16 INCHES O.C., AND <br />NOT MORE THAN 2 INCHES FROM ABUTTING CONSTRUCTION, AT EACH SIDE OF <br />OPENINGS, AND AT CORNERS. <br />3. FIT RUNNERS UNDER AND ABOVE OPENINGS; SECURE INTERMEDIATE STUDS AT <br />SPACING OF WALL STUDS. <br />4. BRACE PARTITION FRAMING SYSTEM AND MAKE RIGID. <br />5. INSTALL DOUBLE STUDS CONTINUOUS FROM FLOOR TO CEILING TRACK AT THE JAMB <br />OF EACH DOOR FRAME AND CASED OPENING. STUDS SHALL BE THE SAME GAGE AS <br />THE ADJACENT STUDS, BUT NO LESS THAN 20 GAGE. PROVIDE DIAGONAL STEEL STUD <br />BRACING TO STRUCTURE AT EACH JAMB AT PARTITIONS WHICH DO NOT EXTEND TO <br />STRUCTURE. <br />6. COORDINATE ERECTION OF STUD SYSTEM WITH REQUIREMENTS OF DOOR AND <br />WINDOW FRAMES, FIRE EXTINGUISHER CABINETS, RECESSED TOILET ACCESSORIES, <br />ACCESS DOORS, AND OTHER CONSTRUCTION WITHIN MOUNTED PARTITION <br />CONSTRUCTION. <br />7. COORDINATE THE INSTALLATION OF FRAMING WITH THE GYPSUM BOARD INSTALLER TO <br />ENSURE SUPPORT AT ALL BOARD EDGES. PROVIDE FRAMING IMMEDIATELY EITHER <br />SIDE OF EXPANSION JOINTS. <br />8. STUD SPLICING NOT PERMISSIBLE. <br />9. AT NON -LOAD BEARING FULL HEIGHT PARTITIONS SUBJECT TO COMPRESSION CAUSED <br />BY OVERHEAD STRUCTURAL DEFLECTION, CUT STUDS 1/2 INCH SHORT FROM FULL <br />HEIGHT, EXCEPT AS OTHERWISE INDICATED. DO NOT RIGIDLY CONNECT STUD TO TOP <br />RUNNER. <br />10. STUD BRIDGING: <br />a. AT INTERIOR PARTITIONS GREATER THAN 4 FEET IN LENGTH, AND WITH RIGID FACING <br />MATERIAL ON ONE STUD FLANGE ONLY, PROVIDE 3/4" BRIDGING CHANNELS IN <br />HORIZONTAL ROWS AT A MAXIMUM OF 5'-0" ON CENTER FOR THE FULL HEIGHT OF THE <br />PARTITION. <br />b. INTERIOR FULL HEIGHT PARTITIONS (STUDS EXTENDING FROM THE FLOOR TO THE <br />STRUCTURE ABOVE) WITH RIGID FACING MATERIAL STOPPING T-0" OR MORE BELOW TOP <br />OF STUDS - PROVIDE ONE ROW 3/4" BRIDGING CHANNEL HORIZONTALLY AT TERMINATION <br />OF GYPSUM BOARD MATERIAL, AND ONE ADDITIONAL ROW FOR EACH 5'-0" OF EXPOSED <br />STUDS. <br />C. INSTALL STUD BRIDGING CHANNELS IN LONG LENGTHS, WIRE TYING AND LAPPING THE <br />JOINTS A MINIMUM OF 12." <br />11. ATTACH BRIDGING CHANNEL TO EACH STUD AS SHOWN IN MANUFACTURER'S PRINTED <br />INSTRUCTIONS. <br />12. INSTALL SECURITY MESH AT ALL WALLS OF THE INVENTORY ROOM PER SECTION <br />092200. <br />F. CEILING AND SOFFIT FRAMING: <br />1. COORDINATE LOCATIONS OF HANGERS AND SUPPORTS WITH THE WORK OF OTHER <br />SECTIONS. <br />2. PROVIDE CEILING AND SOFFIT FRAMING AS INDICATED. WHERE NOT INDICATED <br />PROVIDE, STUD AND RUNNER FRAMING, SUSPENDED FRAMING, OR PROPRIETARY <br />SUSPENDED FRAMING. <br />3. PROPRIETARY SUSPENDED FRAMING: INSTALL IN ACCORDANCE WITH <br />MANUFACTURER'S RECOMMENDATIONS. <br />4. STUD AND RUNNER FRAMING: <br />a. SECURE RUNNERS TO STRUCTURE ABOVE WITH FASTENERS AT A MAXIMUM OF 24 INCHES <br />ON CENTER. SIZE FASTENERS AND USE REINFORCEMENTS AS NECESSARY TO SUPPORT <br />THE DEAD LOADS APPLIED. <br />b. SCREW FASTEN FRAMING AT EACH FLANGE JOINT. <br />c. SPACE STUDS AT 16 INCHES ON CENTER AT HORIZONTAL LOCATIONS. <br />d. SELECT MEMBERS TO MEET THE STRUCTURAL REQUIREMENTS SPECIFIED. <br />5. LIGHT GAGE SUSPENDED FRAMING: <br />a. INSTALL IN ACCORDANCE WITH ASTM C754, UNLESS INDICATED OR SPECIFIED <br />OTHERWISE. <br />b. SUSPEND CEILING FROM OVERHEAD STRUCTURAL ELEMENTS ONLY. DO NOT SUPPORT <br />FROM ANY ELECTRICAL, HVAC, PLUMBING, OR SPRINKLER SYSTEM COMPONENTS. <br />c. SPACE CARRYING CHANNELS 4 FEET ON CENTER WITH SPLICES LAPPED 12 INCHES AND <br />TIED. <br />d. SUPPORT COLD ROLLED CARRYING CHANNELS WITH HANGER WIRES SPACED AT 3 FEET <br />ON CENTER FOR LATH AND PLASTER CEILINGS AND 4 FEET ON CENTER FOR GYPSUM <br />BOARD CEILINGS. LOOP HANGER WIRE AROUND SUPPORT ELEMENT AND TIGHTLY WRAP <br />AROUND VERTICAL WIRE 3 TIMES; CUT OFF NEATLY. <br />' ON � \ ■- , <br />D E <br />e. SPACE FURRING CHANNELS 16" O.C. WITH SPLICES LAPPED 12", MINIMUM AND TIED; CLIP <br />OR SADDLE TIE TO RUNNER CHANNELS WITH 16-GAGE TIE WIRE. <br />f. WHERE OVERHEAD OBSTRUCTIONS PREVENT THE REGULAR SPACING OF HANGERS, <br />PROVIDE SECONDARY CARRYING MEMBERS FOR INDIRECT SUPPORT OF THE <br />SUSPENSION SYSTEM, OR REINFORCE THE NEAREST ADJACENT HANGERS AND RELATED <br />FRAMING COMPONENTS AS REQUIRED TO SPAN THE REQUIRED DISTANCE. <br />6. STABILIZE SUSPENDED CEILING, SOFFIT, AND FASCIA FRAMING AGAINST LATERAL <br />MOVEMENT BY MEANS OF DIAGONAL BRACING. AT LOCATIONS WHERE PARTITIONS <br />EXTEND TO CEILING, ONLY, INSTALL SUPPLEMENTARY BRACING AT MAXIMUM 8'-0" O.C. <br />ALONG LENGTH OF PARTITION, AND ABOVE EACH DOOR HINGE AND STRIKE JAMB. <br />7. FORM OPENINGS IN CEILINGS AND FRAME OPENINGS FOR RECESSED LIGHT FIXTURES, <br />AIR DIFFUSERS, ACCESS DOORS, HATCHES, ETC. <br />8. INSTALL SUPPLEMENTARY HANGER WIRES FOR SUPPORT OF CEILING MOUNTED <br />EQUIPMENT. <br />G.BACKING: <br />1. PROVIDE STEEL BACKING WHERE INDICATED. AT CONTRACTOR'S OPTION STEEL <br />BACKING PLATES MAY BE SUBSTITUTED FOR WOOD BLOCKING, EXCEPT WOOD <br />BLOCKING SHALL BE USED AT THE FOLLOWING LOCATIONS: HANDRAILS, GUARDRAILS, <br />GRAB BARS, AND SIMILAR SAFETY ITEMS. <br />2. UNLESS INDICATED OTHERWISE, STEEL BACKING SHALL CONSIST OF MINIMUM 4 INCH <br />WIDE 16 GAGE STEEL PLATE SCREWED RIGIDLY TO THE STUDS. <br />H. INSTALLATION TOLERANCES: <br />1. INSTALL MEMBERS TO PROVIDE SURFACE PLANE WITH MAXIMUM VARIATION OF 1/8 <br />INCH IN 10 FEET IN ANY DIRECTION. <br />2. LOCATE ASSEMBLIES WITHIN 1/4 INCH OF REQUIRED LOCATIONS. <br />METAL STUD SCHEDULE <br />INTERIOR <br />HEIGHT <br />STUD <br />FLANGE <br />GAGE <br />SPACING <br />12'4" <br />3 5/8" <br />1 5/8" <br />20 <br />24" O.C. <br />14'-0" <br />3 5/8" <br />1 5/8" <br />20 <br />16" O.C. <br />16'4" <br />3 5/8" <br />1 5/8" <br />18 <br />16" O.C. <br />18'4" <br />3 5/8" <br />1 5/8" <br />1 16 <br />12" O.C. <br />EXTERIOR <br />HEIGHT <br />STUD <br />FLANGE <br />GAGE <br />SPACING <br />12'-0" <br />6" <br />2" <br />18 <br />16" O.C. <br />14'-0" <br />6" <br />2" <br />16 <br />12" O.C. <br />16'-0" <br />6" <br />2 1/2" <br />14 <br />12" O.C. <br />18'-0" <br />6" <br />2 1/2" <br />12 <br />12" O.C. <br />092200 INVENTORY ROOM SPECIFICATIONS <br />A.WALLS AND CEILING <br />1. WALLS MUST BE DECK -TO -DECK, CEILING TO HARD DECK CEILING, OR 6" ABOVE <br />CEILING AS DESCRIBED IN THE WALL TYPES ON SHEET A531. <br />2. HARDENING: EXPANDED CARBON STEEL AND FIBER -CEMENT BACKERBOARD <br />MATERIALS MUST BE INSTALLED ON THE INTERIOR SIDE OF THE INVENTORY ROOM <br />WALL STUDS. <br />a. EXPANDED CARBON STEEL SECURITY MESH: AMICO (ALABAMA METAL INDUSTRIES CORP) <br />BIRMINGHAM AL (800/366-2642); ASM .50-13F, MINIMUM 13 GAGE, UNLESS APPROVED <br />OTHERWISE. INSTALL ON THE INTERIOR SIDE OF THE WALL STUDS. <br />I. STEEL MUST MEET OR EXCEED ASTM A-569 HSLA STEEL. CONVENTIONAL EXPANDED <br />CARBON STEEL THAT IS NOT MANUFACTURED SPECIFICALLY FOR SECURITY PURPOSES <br />IS NOT ACCEPTABLE FOR THIS USE. <br />11. CARBON STEEL (MESH) SIZE OPENINGS MAY NOT EXCEED THE FOLLOWING <br />DIMENSIONS: 0.5 INCH X 1.26 INCHES. <br />III.ANCHOR THE EXPANDED CARBON STEEL (INCLUDING ALL SEAMS) TO EACH STUD <br />USING SECURE CLIPS [AMICO SECURA CLIPS] (FASTENERS WITH AN EXPANDED <br />SURFACE AREA) WITH FLAT HEAD, PHILLIPS, ONE-WAY, STEEL SCREWS SPACED NO <br />MORE THAN 12 INCHES APART VERTICALLY (DRYWALL SCREWS ARE UNACCEPTABLE). <br />STEEL SCREWS MUST PENETRATE THROUGH THE STUDS BY AT LEAST 0.25 INCH, PER <br />MANUFACTURER INSTRUCTIONS. <br />IV. END JOINTS MUST BE BUTTED AND OCCUR OVER STUDS. IF OVERLAPPING IS <br />NECESSARY, A LONGER SCREW MUST BE USED TO MAINTAIN A 0.25 INCH STUD <br />PENETRATION. <br />B. FIBER -CEMENT BACKERBOARD <br />I. INSTALL 0.5 INCH FIBER -CEMENT HARDIBACKER (JAMES HARDIE BUILDING PRODUCTS, <br />INC.) BACKERBOARD ON THE INTERIOR SIDE OF THE WALL STUDS (BUT DIRECTLY OVER <br />THE EXPANDED CARBON STEEL). <br />11. HARDIBACKER FIBER -CEMENT BACKERBOARD MUST BE INSTALLED IN ACCORDANCE <br />WITH THE MANUFACTURER'S INSTRUCTIONS. HARDIBACKER INFORMATION CAN BE <br />FOUND AT: <br />HTTP://WVWV.JAMESHARD IE.COM/BACKERBOARD/HOMEOWNER/HARDI BACKER500, PHP <br />III.END JOINTS MUST BE BUTTED AND OCCUR OVER STUDS. <br />4. AVOID VENTS IN THE INVENTORY ROOMS. IF REQUIRED, VENTS OR LOUVERS MUST BE: <br />a. NO GREATER THAN 24 SQUARE INCHES AND LOCATED BEHIND (EXTERIOR SIDE OF) THE <br />EXPANDED CARBON STEEL DESCRIBED IN SECTION 1.3.1 (ABOVE). <br />b. SUPPLY / RETURN DUCTS SHALL NOT EXCEED 24" SQUARE. INSTALL BURGLAR BARS IF <br />OPENING EXCEEDS THE RECOMMENDED SIZES. <br />B. INVENTORY ROOM DOOR (SEE DOOR SCHEDULE AND BELOW) <br />1. INVENTORY ROOMS MAY ONLY HAVE ONE (1) ACCESS POINT/DOOR. <br />2. DUTCH DOORS MUST NOT BE INSTALLED. <br />3. THE DOOR MUST BE METAL OR OF SOLID CORE WOOD CONSTRUCTION, AND A MINIMUM <br />OF 1.75 INCHES THICK. <br />a. A METAL DOOR MUST BE OF 16-GAUGE STEEL. E-016; <br />b. A SOLID CORE WOODEN DOOR REQUIRES A 16-GAUGE STEEL SKIN. <br />c. THE DOOR MAY NOT HAVE VENTS, LOUVERS, OR CONTAIN ANY OPENINGS OTHER THAN <br />THOSE NECESSARY TO AFFIX THE DOOR HARDWARE/HANDLE. <br />4. THE DOOR FRAME MUST BE STEEL AND REINFORCED TO ENSURE DURABILITY. <br />a. THE STEEL FRAME MUST BE ANCHORED TO THE WALL IN ACCORDANCE WITH <br />MANUFACTURER INSTRUCTIONS OR BEST PRACTICES; <br />b. SUPPORTING WALL STRUCTURES MUST CONSIST OF DOUBLE STUDDING OR FRAMING OF <br />EQUIVALENT STRENGTH; AND <br />c. THERE MUST NOT BE MORE THAN 0.125 INCH CLEARANCE BETWEEN THE DOOR AND THE <br />FRAME. <br />5. THE DOOR MUST BE EQUIPPED WITH A PROPERLY FUNCTIONING, COMMERCIAL GRADE, <br />AUTOMATIC DOOR CLOSER DEVICE. <br />6. IF THE DOOR HINGES ARE ACCESSIBLE FROM THE EXTERIOR SIDE, THE HINGE MUST BE <br />A HEAVY DUTY CONTINUOUS (PIANO OR ROTON) HINGE. <br />7. THE DOOR MUST BE EQUIPPED WITH A LATCH GUARD COVERING THE EXTERIOR LATCH <br />EXPOSURE. <br />CLOCKS/ KEYS <br />1. INVENTORY ROOM DOORS MUST BE EQUIPPED WITH HIGH QUALITY, COMMERCIAL <br />GRADE LOCKS THAT: <br />a. USE MANUFACTURER -RESTRICTED KEYWAYS (INCLUDING INSTAKEY) AND <br />b. CANNOT BE SET IN AN UNLOCKED STATE (I.E., STOREROOM FUNCTION). <br />2. THE SECURITECH 4850 MP 5 POLICE LOCK (5-POINT SECURITY LOCK) LOCKING SYSTEM <br />MUST BE INSTALLED ON THE INTERIOR SIDE OF THE INVENTORY ROOM TO SECURE THE <br />INVENTORY ROOM DOOR AFTER HOURS. SECURITECH 4850 INFORMATION CAN BE <br />FOUND AT: <br />a. HTTP://WVWV.SECURITECH.COM/DO1-MP-POLICE-LOCK.HTML AND <br />b. <br />HTTP://WWW. SECURITECH,COM/WE/20CATALOG/4/20MULTI-POINT/20LOCKING/D18. PDF <br />092813 GYPSUM SHEATHING <br />A. MATER IALS: <br />1. GYPSUM SHEATHING: ONE OF THE FOLLOWING: <br />A. G-P GYPSUM CORPORATION "DENS -GLASS GOLD"; GLASS MAT FACED; ASTM C1177; 1/2 <br />INCH THICK <br />B. USG FIBEROCK BRAND SHEATHING WITH AQUA -TOUGH TM; 1/2 INCH THICK. <br />2. SCREWS: GALVANIZED; SELF -DRILLING; SELF -DRILLING, BUGLE HEAD SCREWS; <br />MINIMUM 1-1/4 INCH LONG. <br />B. INSTALLATION: <br />1. INSTALL SQUARE EDGE BOARDS PARALLEL OR PERPENDICULAR TO FRAMING. INSTALL <br />BOARDS PARALLEL TO FRAMING AT FIRE RATED WALLS. APPLY SHEATHING WITH <br />JOINTS STAGGERED. ALL EDGES SHALL BE FIRMLY SUPPORTED. <br />2. INSTALL SHEATHING WITH COATING TOWARDS EXTERIOR. <br />3. SCREW TO FRAMING. SPACE FASTENERS 8 INCHES O.C. IN FIELD AND 4 INCHES O.C. AT <br />ENDS ALONG EACH FRAMING MEMBER. <br />4. 4. DO NOT BRIDGE EXPANSION OR SEISMIC JOINTS. <br />DI" SIO D0 <br />092900 GYPSUM BOARD <br />A. QUALITY CONTROL: <br />1. PROVIDE ASSEMBLIES MEETING THE HOURLY FIRE RATINGS INDICATED. ASSEMBLIES <br />SHALL BE APPROVED BY THE LOCAL JURISDICTIONAL CODE AUTHORITIES. <br />B. MATERIALS: <br />1. SYNTHETIC GYPSUM BOARD: <br />a. MANUFACTURERS: NATIONAL GYPSUM CO. "GOLD BOND BRAND"; USG <br />CORPORATION, "SHEETROCK BRAND"; TEMPLE -INLAND GYPSUM, "SYNTHETIC GYPSUM." <br />b. 5/8 INCH THICK UNLESS NOTED OTHERWISE; PROVIDE TYPE X IN FIRE RATED PARTITIONS. <br />c. STANDARD BOARD: ASTM C36. <br />2. ACCESSORIES: <br />a. TRIM: CONCEALED FLANGE SCREW -ON TYPE; METAL: GA 216. <br />b. JOINT COMPOUND, TAPE, AND FINISHING COMPOUND: ASTM C475 AND GA 216. <br />c. SCREWS: ASTM C1002. <br />d. PROPRIETARY SKIM COAT: USG "TUFF -HIDE SHEETROCK BRAND PRIMER -SURFACER." <br />C. INSTALLATION: <br />1. INSTALLATION STANDARD: UNLESS SPECIFIED OTHERWISE, PERFORM WORK IN <br />ACCORDANCE WITH GYPSUM ASSOCIATION 216, "RECOMMENDED SPECIFICATIONS FOR <br />THE APPLICATION AND FINISHING OF GYPSUM WALLBOARD." <br />2. INSTALL WATER RESISTANT BOARD RESTROOM WALLS AS A SUBSTRATE FOR <br />SURFACES <br />3. SCREW FASTEN BOARD TO FRAMING, UNLESS APPROVED OTHERWISE. <br />4. TRIM: <br />a. USE LONGEST PRACTICAL LENGTHS, WITH NO PIECE LESS THAN 2 FEET LONG FOR <br />CONTINUOUS RUNS GREATER THAN 8 FEET. SECURELY FASTEN AND ALIGN TRIM ENDS AT <br />JOINTS. <br />b. PLACE CONCEALED FLANGE CORNER BEADS AT ALL EXTERNAL CORNERS. AT ANGLES <br />OTHER THAN 90 DEGREES, BEND THE FLANGE TO CONFORM TO THE ANGLE. <br />c. PLACE CONCEALED FLANGE TYPE L TRIM WHERE GYPSUM BOARD ABUTS DISSIMILAR <br />MATERIALS. <br />d. USE J TRIM AT EXPOSED GYPSUM BOARD EDGES (INCLUDING LIGHT COVES) WHERE <br />SEALANT JOINT IS INDICATED. <br />5. CONTROL JOINTS: <br />a. POSITION CONTROL JOINTS TO INTERSECT LIGHT FIXTURES, AIR DIFFUSERS, DOOR <br />OPENINGS, AND OTHER AREAS OF STRESS CONCENTRATION. <br />b. POSITION CONTROL JOINTS AT LOCATIONS WHERE EXPANSION OR CONTROL JOINTS <br />OCCUR IN THE BUILDING STRUCTURE. <br />c. LOCATE CONTROL JOINTS TO FORM RECTANGULAR OR SQUARE SECTIONS, IN "L," "U," "T," <br />OR OTHER IRREGULARLY SHAPED AREAS. <br />6. FINISHING: <br />a. PROVIDE FINISHING IN ACCORDANCE WITH GA 214. <br />b. WHERE NECESSARY TO SAND, DO SO WITHOUT DAMAGING THE FACE OF THE GYPSUM <br />BOARD. <br />c. LEVELS OF FINISH: PROVIDE AS NOTED IN DRAWINGS <br />c.a. LEVEL 4: SALES AREA. PROVIDE UNLESS INDICATED OR SPECIFIED OTHERWISE. <br />c.b. LEVEL 3: PUBLIC TOILET ROOMS & HALLWAYS OR AS NOTED ON DRAWINGS. <br />c.c. LEVEL 2: BACK OF HOUSE, STORAGE ROOMS, MECHANICAL ROOMS, JANITOR'S CLOSETS <br />OR AS NOTED ON DRAWINGS. <br />CA. LEVEL 1: PROVIDE AT THE FOLLOWING LOCATIONS: <br />c.d.a. SURFACES OF FIRE RATED ASSEMBLIES CONCEALED FROM VIEW IN THE FINISHED <br />WORK ("FIRE TAPING"). <br />c.d.b. SURFACES OF ACOUSTICAL ASSEMBLIES CONCEALED FORM VIEW IN THE FINISHED <br />WORK <br />c.e. LEVEL 0: PROVIDE AT THE FOLLOWING LOCATIONS:SURFACES OF NON -FIRE RATED <br />ASSEMBLIES CONCEALED FROM VIEW IN THE FINISHED WORKLEVEL 4 AND 5 FINISHES: <br />RETURN TO THE SITE AFTER PRIMER IS APPLIED, AND TOUCH-UP SURFACE DEFECTS. <br />D. PROPRIETARY SKIM COAT MATERIAL MAYBE USED IN LIEU OF JOINT COMPOUND AS SKIM <br />COAT AT LEVEL 5 SURFACES <br />093105 CERAMIC TILE <br />A. GENERAL <br />1. RELATED DOCUMENTS <br />a. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND <br />SUPPLEMENTARY CONDITIONS AND OTHER DIVISION 1 SPECIFICATION SECTIONS, APPLY <br />TO THIS SECTION. <br />b. STATIC COEFFICIENT OF FRICTION: FOR TILE INSTALLED ON WALKWAY SURFACES, <br />PROVIDE PRODUCTS WITH THE FOLLOWING VALUES AS DETERMINED BY TESTING <br />IDENTICAL PRODUCTS PER ASTM C 1028: <br />c. LEVEL SURFACES: MINIMUM 0.6. <br />B. PRODUCTS <br />1. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE <br />PRODUCTS AS SHOWN ON FINISH MATERIAL SCHEDULE. <br />a. TILE -SETTING AND -GROUTING MATERIALS: AS SHOWN ON FINISH MATERIAL SCHEDULE. <br />2. ANSI CERAMIC TILE STANDARD: PROVIDE TILE THAT COMPLIES WITH STANDARD GRADE <br />REQUIREMENTS OF ANSI A137.1, "SPECIFICATIONS FOR CERAMIC TILE," FOR TYPES, <br />COMPOSITIONS, AND OTHER CHARACTERISTICS INDICATED. <br />3. ANSI STANDARDS FOR TILE INSTALLATION MATERIALS: PROVIDE MATERIALS <br />COMPLYING WITH REFERENCED ANSI STANDARDS, <br />4. COLORS, TEXTURES, AND PATTERNS: FOR TILE, GROUT, AND OTHER PRODUCTS <br />REQUIRING SELECTION OF COLORS, SURFACE TEXTURES, PATTERNS, AND OTHER <br />APPEARANCE CHARACTERISTICS, COMPLY WITH THE FOLLOWING REQUIREMENTS: <br />a. MATCH COLORS, TEXTURES, AND PATTERNS INDICATED BY REFERENCING <br />MANUFACTURER'S STANDARD DESIGNATIONS FOR THESE CHARACTERISTICS. <br />5. FACTORY BLENDING: FOR TILE EXHIBITING COLOR VARIATIONS WITHIN THE RANGES <br />SELECTED DURING SAMPLE SUBMITTALS, BLEND TILE IN THE FACTORY AND PACKAGE <br />SO TILE UNITS TAKEN FROM ONE PACKAGE SHOW THE SAME RANGE IN COLORS AS <br />THOSE TAKEN FROM OTHER PACKAGES AND MATCH APPROVED SAMPLES. <br />6. FLOOR TILE: PROVIDE FLAT TILE COMPLYING WITH THE FOLLOWING REQUIREMENTS: <br />a. COMPOSITION: AS NOTED IN DRAWINGS. <br />b. FACIAL DIMENSIONS: AS NOTED IN DRAWINGS. <br />c. THICKNESS: AS NOTED IN DRAWINGS <br />d. FACE: AS NOTED IN DRAWINGS. <br />e. FOR LATEX-PORTLAND CEMENT MORTARED AND GROUTED PAVER TILE, PRE -COAT WITH <br />TEMPORARY PROTECTIVE COATING. <br />7. 7. WALL TILE: PROVIDE FLAT TILE COMPLYING WITH THE FOLLOWING REQUIREMENTS: <br />a. MODULE SIZE: AS NOTED IN DRAWINGS <br />b. THICKNESS: AS NOTED IN DRAWINGS <br />c. FACE: AS NOTED IN DRAWINGS <br />d. MOUNTING: PRE -GROUTED SHEETS OF TILES FACTORY ASSEMBLED AND GROUTED WITH <br />MANUFACTURER'S STANDARD SILICONE RUBBER COMPLYING WITH ANSI A118.6. <br />8. WATERPROOFING FOR THIN -SET TILE INSTALLATIONS: PROVIDE PRODUCTS THAT <br />COMPLY WITH ANSI Al18.10. <br />9. SETTING MATERIALS: AS FOLLOWS: <br />a. LATEX-PORTLAND CEMENT MORTAR: ANSI A118.4, COMPOSED AS FOLLOWS: <br />b. PREPACKAGED DRY -MORTAR MIX: FACTORY -PREPARED MIXTURE OF PORTLAND CEMENT; <br />DRY, REDISPERSIBLE, ETHYLENE VINYL ACETATE ADDITIVE; AND OTHER INGREDIENTS TO <br />WHICH ONLY WATER NEEDS TO BE ADDED AT PROJECT SITE. <br />c. MIXTURE OF DRY -MORTAR MIX AND LATEX ADDITIVE: MIXTURE OF PREPACKAGED <br />DRY -MORTAR MIX AND LIQUID -LATEX ADDITIVE COMPLYING WITH THE FOLLOWING <br />REQUIREMENTS: <br />10. LATEX ADDITIVE: STYRENE BUTADIENE RUBBER. <br />11. LATEX ADDITIVE: ACRYLIC RESIN. <br />a. CHEMICAL -RESISTANT, WATER -CLEANABLE, CERAMIC TILE -SETTING AND -GROUTING <br />EPDXY: ANSI A118.3. <br />b. PROVIDE PRODUCT CAPABLE OF RESISTING CONTINUOUS AND INTERMITTENT EXPOSURE <br />TO TEMPERATURES OF UP TO 140 DEG F (60 DEG C) AND 212 DEG F (100 DEG C), <br />RESPECTIVELY, AS CERTIFIED BY MORTAR MANUFACTURER FOR INTENDED USE. <br />c. WATER -CLEANABLE, TILE -SETTING EPDXY ADHESIVE: ANSI A118.3. <br />d. GROUT FOR EXTERIOR: LATICRETE 4237 LATEX THIN SET MORTAR ADDITIVE WITH 211 <br />CRETE FILLER POWDER OR LATICRETE 3701 LATEX ADMIXTURE WITH LATICRETE FLOOR <br />AND WALL THIN SET. PROVIDE LATICRETE 9235 WATERPROOF MEMBRANE PER MFR. <br />RECOMMENDATIONS. <br />12. GROUTING MATERIALS: AS FOLLOWS: <br />a. LATEX-PORTLAND CEMENT GROUT: ANSI A118.6 FOR MATERIALS DESCRIBED IN SECTION <br />H-2.4, COMPOSED AS FOLLOWS: <br />a.a. MIXTURE OF DRY -GROUT MIX AND LATEX ADDITIVE: MIXTURE OF FACTORY -PREPARED, <br />DRY -GROUT MIX AND LATEX ADDITIVE COMPLYING WITH THE FOLLOWING <br />REQUIREMENTS: <br />13. UNSANDED DRY -GROUT MIX: DRY -SET GROUT COMPLYING WITH ANSI A118.6 FOR <br />MATERIALS DESCRIBED IN SECTION H-2.3, FOR JOINTS 1/8 INCH (3.2 MM) AND <br />NARROWER. <br />14. SANDED DRY -GROUT MIX: COMMERCIAL PORTLAND CEMENT GROUT COMPLYING WITH <br />ANSI A118.6 FOR MATERIALS DESCRIBED IN SECTION H-2.1, FOR JOINTS 1/8 INCH (3.2 <br />MM) AND WIDER. <br />15. LATEX ADDITIVE: STYRENE BUTADIENE RUBBER. <br />16. LATEX ADDITIVE: ACRYLIC RESIN. <br />Mobile <br />12920 SE 38th STREET <br />BELLEVUE, WA 98006 <br />www.T-Mobile.com <br />COPYRIGHT NOTICE: <br />THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO <br />COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK' UNDER SEC. 102 OF <br />THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED JANUARY 2003. THE PROTECTION <br />INCLUDES. WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND <br />COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH <br />PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS <br />MAY RESULT IN CESSATION OF CONSTRUCTION, BUILDING SEIZURE, AND/OR <br />MONETARY LIABILITY. <br />ARCHITECT <br />rmUzioN <br />9096 EAST BAHIA DRIVE <br />SUITE 103 <br />SCOTTSDALE, AZ 85260 <br />DESIGN@FUZIONVE.COM <br />WM.FUZIONVE.COM <br />VENDOR PROJECT NO: 21.11.212680 <br />�Q•�i. O F FL O <br />•���P,<,(t LOUI,Sy4�✓ •0'9 <br />100 4 ' <br />'SrFR�D <br />02/10/2022 <br />CONSULTING ENGINEER: <br />DESCROMON DATE <br />DATE: February 5, 2022 <br />,„ <br />SCALE: AS NOTED <br />DRAWN BY: LEO V. <br />SAP NUMBER: <br />4SIR <br />CORPORATE TENANT REBUILD <br />LDC <br />SHEET TITLE: <br />SPECIFICATIONS <br />4 <br />3 <br />2 <br />SHEET NUMBER: <br />A704 <br />.;i <br />