Laserfiche WebLink
JI t 11111 1 1 I <br />1 4 <br />II 1 II 1 1 1 <br />3 <br />I III I I 1 11 1111 1 1 1 11 11 _iI _ I I <br />2 <br />vl <br />ml <br />QI <br />u s <br />DIV ► <br />16.a. CHEMICAL -RESISTANT EPDXY GROUT: ANSI A118.3, COLOR AS INDICATED. <br />16.b. PROVIDE PRODUCT CAPABLE OF RESISTING CONTINUOUS AND INTERMITTENT EXPOSURE <br />TO TEMPERATURES OF UP TO 140 DEG F (60 DEG C) AND 212 DEG F (100 DEG C), <br />RESPECTIVELY, AS CERTIFIED BY MORTAR MANUFACTURER FOR INTENDED USE. <br />17. ELASTOMERIC SEALANTS: PROVIDE MANUFACTURER'S STANDARD CHEMICALLY <br />CURING, ELASTOMERIC SEALANTS OF BASE POLYMER AND CHARACTERISTICS <br />INDICATED THAT COMPLY WITH APPLICABLE REQUIREMENTS OF DIVISION 7 SECTION <br />"JOINT SEALANTS." <br />17.a. ONE -PART, MILDEW -RESISTANT SILICONE SEALANT: ASTM C 920; TYPE S; GRADE NS; <br />CLASS 25; USES NT, G, A, AND, AS APPLICABLE TO NONPOROUS JOINT SUBSTRATES <br />INDICATED, 0; FORMULATED WITH FUNGICIDE. <br />18. CEMENTITIOUS BACKER UNITS: PROVIDE PRODUCTS COMPLYING WITH ANSI A118.9, OF <br />THICKNESS AND WIDTH INDICATED, AND IN MAXIMUM LENGTHS AVAILABLE TO MINIMIZE <br />END -TO -END BUTT JOINTS. <br />19. MISCELLANEOUS MATERIALS: AS FOLLOWS: <br />a. TROWELABLE UNDERLAYMENTS AND PATCHING COMPOUNDS: LATEX -MODIFIED, <br />PORTLAND-CEMENT-BASED FORMULATION PROVIDED OR APPROVED BY MANUFACTURER <br />OF TILE -SETTING MATERIALS FOR INSTALLATIONS INDICATED. <br />b. METAL EDGE STRIPS: WHITE -ZINC -ALLOY TERRAZZO STRIPS, 1/8 INCH (3,2 MM) WIDE AT <br />TOP EDGE WITH INTEGRAL PROVISION FOR ANCHORAGE TO MORTAR BED OR SUBSTRATE, <br />UNLESS OTHERWISE INDICATED. <br />20. WATERPROOF MEMBRANE INSTALLATION: (COORDINATE WITH LANDLORD <br />REQUIREMENTS) <br />a. INSTALL WATERPROOF MEMBRANES IN STRICT ACCORDANCE WITH MANUFACTURER'S <br />INSTALLATION INSTRUCTIONS. <br />C.PREPARATION: CLEAN SUBSTRATE SURFACES FREE OF GREASE, DIRT, DUST, ORGANIC <br />IMPURITIES, CURING AGENTS, AND OTHER MATERIALS THAT WOULD IMPAIR BOND. <br />CLEAN FLOORS WITH "BLAST -TRACK" UNIT IF NECESSARY. <br />1. SLAB LEVELING: (COORDINATE WITH LANDLORD REQUIREMENTS) <br />2. PRIOR TO INSTALLATION OF THINSET FLOOR TILE, WHERE LOCAL IRREGULARITIES IN <br />THE SUBSTRATE SURFACE WOULD PREVENT LEVEL INSTALLATION OF THE TILE, THE <br />SUBSTRATE SHALL BE BROUGHT TO PLANE SURFACE WITH VARIATIONS NOT TO <br />EXCEED 1/8 INCH IN 4 FEET (CUMULATIVE) AND 1/4 INCH IN 10 FEET (NON -CUMULATIVE). <br />SMOOTH ALL ABRUPT CHANGES IN PLANE. <br />3. USE THINSET MORTAR OR OTHER FILLER FOR SLAB LEVELING. OTHER FILLERS ARE <br />SUBJECT TO ENDORSEMENT BY THE SETTING MORTAR MANUFACTURER. <br />4. SCREED OR FLOAT TO APPROPRIATE THICKNESS AND SPECIFIED SURFACE <br />TOLERANCE. ALLOW TO SET PRIOR TO PROCEEDING WITH INSTALLATION, DO NOT <br />EXCEED THE MAXIMUM THICKNESSES FOR THIN BED MORTAR AS RECOMMENDED BY <br />THE MANUFACTURER. <br />D. EXECUTION <br />1. PROVIDE CONCRETE SUBSTRATES FOR TILE FLOORS INSTALLED WITH DRY -SET OR <br />LATEX-PORTLAND CEMENT MORTARS THAT COMPLY WITH FLATNESS TOLERANCES <br />SPECIFIED IN REFERENCED ANSI A108 SERIES OF TILE INSTALLATION STANDARDS FOR <br />INSTALLATIONS INDICATED. <br />a. USE TROWELABLE LEVELING AND PATCHING COMPOUNDS PER TILE -SETTING MATERIAL <br />MANUFACTURER'S WRITTEN INSTRUCTIONS TO FILL CRACKS, HOLES, AND DEPRESSIONS. <br />b. REMOVE PROTRUSIONS, BUMPS, AND RIDGES BY SANDING OR GRINDING. <br />2. BLENDING: FOR TILE EXHIBITING COLOR VARIATIONS WITHIN THE RANGES SELECTED <br />DURING SAMPLE SUBMITTALS, VERIFY THAT TILE HAS BEEN BLENDED IN THE FACTORY <br />AND PACKAGED SO TILE UNITS TAKEN FROM ONE PACKAGE SHOW THE SAME RANGE IN <br />COLORS AS THOSE TAKEN FROM OTHER PACKAGES AND MATCH APPROVED SAMPLES. <br />3. ANSI TILE INSTALLATION STANDARDS: COMPLY WITH PARTS OF ANSI A108 SERIES OF <br />TILE INSTALLATION STANDARDS IN "SPECIFICATIONS FOR INSTALLATION OF CERAMIC <br />TILE" THAT APPLY TO TYPES OF SETTING AND GROUTING MATERIALS AND TO METHODS <br />INDICATED OR REQUIRED. <br />4. TCA INSTALLATION GUIDELINES: TCA'S "HANDBOOK FOR CERAMIC TILE INSTALLATION." <br />COMPLY WITH TCA INSTALLATION METHODS INDICATED OR REQUIRED. <br />5. EXTEND TILE WORK INTO RECESSES AND UNDER OR BEHIND EQUIPMENT AND <br />FIXTURES TO FORM A COMPLETE COVERING WITHOUT INTERRUPTIONS, UNLESS <br />OTHERWISE INDICATED. TERMINATE WORK NEATLY AT OBSTRUCTIONS, EDGES, AND <br />CORNERS WITHOUT DISRUPTING PATTERN OR JOINT ALIGNMENTS. <br />6. ACCURATELY FORM INTERSECTIONS AND RETURNS. PERFORM CUTTING AND DRILLING <br />OF TILE WITHOUT MARRING VISIBLE SURFACES. CAREFULLY GRIND CUT EDGES OF TILE <br />ABUTTING TRIM, FINISH, OR BUILT-IN ITEMS FOR STRAIGHT ALIGNED JOINTS. FIT TILE <br />CLOSELY TO ELECTRICAL OUTLETS, PIPING, FIXTURES, AND OTHER PENETRATIONS SO <br />PLATES, COLLARS, OR COVERS OVERLAP TILE. <br />7. JOINTING PATTERN: LAY TILE IN GRID PATTERN, UNLESS OTHERWISE INDICATED. ALIGN <br />JOINTS WHERE ADJOINING TILES ON FLOOR, BASE, WALLS, AND TRIM ARE THE SAME <br />SIZE. LAY OUT TILE WORK AND CENTER TILE FIELDS IN BOTH DIRECTIONS IN EACH <br />SPACE OR ON EACH WALL AREA. ADJUST TO MINIMIZE TILE CUTTING. PROVIDE <br />UNIFORM JOINT WIDTHS, UNLESS OTHERWISE INDICATED. <br />8. EXPANSION JOINTS: LOCATE EXPANSION JOINTS AND OTHER SEALANT -FILLED JOINTS, <br />INCLUDING CONTROL, CONTRACTION, AND ISOLATION JOINTS, WHERE INDICATED <br />DURING INSTALLATION OF SETTING MATERIALS, MORTAR BEDS, AND TILE. DO NOT <br />SAW - <br />CUT JOINTS AFTER INSTALLING TILES. <br />9. LOCATE JOINTS IN TILE SURFACES DIRECTLY ABOVE JOINTS IN CONCRETE <br />SUBSTRATES. <br />10. PREPARE JOINTS AND APPLY SEALANTS TO COMPLY WITH REQUIREMENTS OF DIVISION <br />7 SECTION "JOINT SEALANTS." <br />11. GROUT TILE TO COMPLY WITH THE REQUIREMENTS OF THE FOLLOWING TILE <br />INSTALLATION STANDARDS: <br />12. FOR CERAMIC TILE GROUTS (SAND-PORTLAND CEMENT, DRY -SET, COMMERCIAL <br />PORTLAND CEMENT, AND LATEX-PORTLAND CEMENT GROUTS), COMPLY WITH ANSI <br />A108.10. <br />13. FLOOR TILE INSTALLATION: INSTALL TILE TO COMPLY WITH REQUIREMENTS INDICATED, <br />INCLUDING THOSE REFERENCING TCA INSTALLATION METHODS AND ANSI A108 SERIES <br />OF TILE STANDARDS. <br />14. JOINT WIDTHS: INSTALL TILE ON FLOORS WITH THE FOLLOWING JOINT WIDTHS: <br />15. PAVER TILE: 1/4 INCH (6.35 MM). <br />16. BACK BUTTERING: FOR INSTALLATIONS INDICATED, OBTAIN 100 PERCENT MORTAR <br />COVERAGE BY COMPLYING WITH APPLICABLE SPECIAL REQUIREMENTS FOR BACK <br />BUTTERING OF TILE IN REFERENCED ANSI A108 SERIES OF TILE INSTALLATION <br />STANDARDS. <br />17. METAL EDGE STRIPS: INSTALL AT LOCATIONS INDICATED OR WHERE EXPOSED EDGE <br />OF TILE FLOORING MEETS CARPET, WOOD, OR OTHER FLOORING THAT FINISHES FLUSH <br />WITH TOP OF TILE. <br />18. WALL TILE INSTALLATION: INSTALL TYPES OF TILE DESIGNATED FOR WALL <br />INSTALLATIONS TO COMPLY WITH MANUFACTURERS' REQUIREMENTS, INCLUDING <br />THOSE REFERENCING TCA INSTALLATION METHODS AND ANSI SETTING -BED <br />STANDARDS. <br />19. JOINT WIDTHS: INSTALL TILE ON WALLS WITH THE FOLLOWING JOINT WIDTHS: <br />20. WALL TILE: 1/16 INCH (1.6 MM). <br />21. BACK BUTTERING: FOR INSTALLATIONS INDICATED, OBTAIN 100 PERCENT MORTAR <br />COVERAGE BY COMPLYING WITH APPLICABLE SPECIAL REQUIREMENTS FOR BACK <br />BUTTERING OF TILE IN REFERENCED ANSI A108 SERIES OF TILE INSTALLATION <br />STANDARDS. <br />22. CLEANING: ON COMPLETION OF PLACEMENT AND GROUTING, CLEAN ALL CERAMIC TILE <br />SURFACES SO THEY ARE FREE OF FOREIGN MATTER. USE CLEANING MATERIALS AND <br />METHODS THAT COMPLY WITH TILE AND GROUT MANUFACTURERS' WRITTEN <br />INSTRUCTIONS. <br />096403 WOOD FLOORING <br />A.GENERAL <br />1. RELATED DOCUMENTS: DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, <br />INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND DIVISION 1 <br />SPECIFICATION SECTIONS, APPLY TO THIS SECTION. <br />2. SUMMARY <br />a. ENGINEERED WOOD FLOOR. <br />3. QUALITY ASSURANCE <br />a. INSTALLER QUALIFICATIONS: INSTALLATION SHALL BE PERFORMED BY A FIRM <br />EXPERIENCED IN THE APPLICATION OF SYSTEMS SIMILAR IN COMPLEXITY TO THOSE <br />REQUIRED FOR THIS PROJECT. ADDITIONALLY, INSTALLERS SHALL BE IN POSSESSION OF <br />THE MANUFACTURER'S INSTALLATION MANUAL AND ADHERE TO THE INSTRUCTIONS. <br />b. HARDWOOD FLOORING: COMPLY WITH NOFMA GRADING RULES FOR SPECIES, GRADE, <br />AND CUT. CERTIFICATION: PROVIDE FLOORING THAT CARRIES NOFMA GRADE STAMP ON <br />EACH BUNDLE OR PIECE. <br />c. MAPLE FLOORING: COMPLY WITH MFMA GRADING RULES FOR SPECIES, GRADE, AND CUT. <br />CERTIFICATION: PROVIDE FLOORING THAT CARRIES MFMA MARK ON EACH BUNDLE OR <br />PIECE. <br />d. SOUTHERN PINE FLOORING: COMPLY WITH SPIB GRADING RULES FOR SPECIES, GRADE, <br />AND CUT. <br />e. SOFTWOOD FLOORING: COMPLY WITH WCLIB NO. 17 GRADING RULES FOR SPECIES, <br />GRADE, AND CUT. <br />4. PROJECT CONDITIONS <br />nn Y11 <br />DI f! - <br />'til <br />} <br />a. CONDITIONING: MAINTAIN RELATIVE HUMIDITY PLANNED FOR BUILDING OCCUPANTS AND <br />AN AMBIENT TEMPERATURE BETWEEN 65 AND 75 DEG F (18 AND 24 DEG C) IN SPACES TO <br />RECEIVE WOOD FLOORING FOR AT LEAST SEVEN DAYS BEFORE INSTALLATION, DURING <br />INSTALLATION, AND FOR AT LEAST SEVEN DAYS AFTER INSTALLATION. AFTER <br />POST -INSTALLATION PERIOD, MAINTAIN RELATIVE HUMIDITY AND AMBIENT TEMPERATURE <br />PLANNED FOR BUILDING OCCUPANTS. <br />b. MOVE WOOD FLOORING INTO SPACES WHERE IT WILL BE INSTALLED, AT LEAST SEVEN <br />DAYS BEFORE INSTALLATION. <br />c. FOR UNFINISHED PRODUCTS, OPEN SEALED PACKAGES TO ALLOW WOOD FLOORING TO <br />ACCLIMATIZE. <br />d. DO NOT INSTALL FLOORING UNTIL IT ADJUSTS TO THE RELATIVE HUMIDITY OF AND IS AT <br />THE SAME TEMPERATURE AS THE SPACE WHERE IT IS TO BE INSTALLED. <br />e. INSTALL FACTORY -FINISHED WOOD FLOORING AFTER OTHER FINISHING OPERATIONS, <br />INCLUDING PAINTING, HAVE BEEN COMPLETED. <br />B. PRODUCTS <br />1. ENGINEERED -WOOD STRIP OR PLANK FLOORING PRODUCTS: AS INDICATED ON THE <br />FINISH MATERIAL SCHEDULE. NO SUBSTITUTIONS. ENGINEERED -WOOD STRIP OR <br />PLANK FLOORING: ANSI/HPVA LF. <br />a. SPECIES: AS INDICATED ON DRAWINGS. <br />b. GRADE: MANUFACTURERS STANDARD. <br />c. THICKNESS: AS NOTED IN DRAWINGS <br />d. CONSTRUCTION: AS NOTED IN DRAWINGS <br />e. WIDTH: AS NOTED IN DRAWINGS <br />f. LENGTH: AS NOTED IN DRAWINGS. <br />g. EDGES: AS NOTED IN DRAWINGS. <br />h. FINISH: AS NOTED IN DRAWINGS. <br />2. ACCESSORY MATERIALS <br />a. WOOD FLOORING ADHESIVE: MASTIC RECOMMENDED BY FLOORING AND ADHESIVE <br />MANUFACTURERS FOR APPLICATION INDICATED. (NOT USED IN FLOATING FLOOR SYSTEM) <br />b. FASTENERS: AS RECOMMENDED BY MANUFACTURER, BUT NOT LESS THAN THAT <br />RECOMMENDED IN NOFMA'S "INSTALLING HARDWOOD FLOORING." (NOT USED IN <br />FLOATING FLOOR SYSTEM) <br />c. VAPOR RETARDER: ASTM D 4397, POLYETHYLENE SHEET NOT LESS THAN [6.0 MILS (0.15 <br />MM)] THICK. <br />d. VERSASHIELD FLOORING UNDERLAYMENT WITH VERSASSHIELD SEAM TAPE INSTALLED <br />PER MANUFACTURER INSTRUCTIONS. <br />e. CORK EXPANSION STRIP: COMPOSITION CORK STRIP COMPLYING WITH FS HH-C-576, TYPE <br />I-B, CLASS 2. <br />f. WOOD FEATURE STRIPS: 2-INCH- (51-MM-) WIDE, SQUARE -EDGED WALNUT STRIPS <br />FURNISHED IN LENGTHS AS LONG AS PRACTICAL AND IN THICKNESS TO MATCH WOOD <br />FLOORING. <br />g. METAL FEATURE STRIPS: 1/8-BY-1/8-INCH (3-BY-3-MM) SOLID BRASS STRIP, DESIGNED FOR <br />INLAYING INTO ROUTED REVEAL IN WOOD FLOORING SURFACE. <br />h. WOOD TRIM: IN SAME SPECIES AND GRADE AS WOOD FLOORING, UNLESS OTHERWISE <br />INDICATED. <br />i. WOOD BASE: 3/4 INCH (16 MM) THICK BY 2 INCHES (100 MM) HIGH. <br />j. BASE SHOE MOLDING: 1/2 BY 3/4 INCH (13 BY 19 MM). <br />k. THRESHOLD: TAPERED ON EACH SIDE AND ROUTED AT BOTTOM OF ONE SIDE TO <br />ACCOMMODATE WOOD FLOORING. <br />I. REDUCER STRIP: AS NOTED IN DRAWINGS. <br />C. PREPARATION: <br />1. CONCRETE SLABS: GRIND HIGH SPOTS AND FILL LOW SPOTS TO PRODUCE A MAXIMUM <br />1/8-INCH (3-MM) DEVIATION IN ANY DIRECTION WHEN CHECKED WITH A 10-FOOT (3-M) <br />STRAIGHT EDGE. <br />2. USE TROWELABLE LEVELING AND PATCHING COMPOUNDS, ACCORDING TO <br />MANUFACTURER'S WRITTEN INSTRUCTIONS, TO FILL CRACKS, HOLES, AND <br />DEPRESSIONS IN SUBSTRATES. <br />3. REMOVE COATINGS, INCLUDING CURING COMPOUNDS, AND OTHER SUBSTANCES ON <br />SUBSTRATES THAT ARE INCOMPATIBLE WITH INSTALLATION ADHESIVES AND THAT <br />CONTAIN SOAP, WAX, OIL, OR SILICONE, USING MECHANICAL METHODS RECOMMENDED <br />BY MANUFACTURER. DO NOT USE SOLVENTS. <br />4. BROOM OR VACUUM CLEAN SUBSTRATES TO BE COVERED IMMEDIATELY BEFORE <br />PRODUCT INSTALLATION. AFTER CLEANING, EXAMINE SUBSTRATES FOR MOISTURE, <br />ALKALINE SALTS, CARBONATION, OR DUST. PROCEED WITH INSTALLATION ONLY AFTER <br />UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. <br />D. EXECUTION <br />1. INSTALLATION <br />A. COMPLY WITH FLOORING MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS, BUT <br />NOT LESS THAN RECOMMENDATIONS IN NOFMA'S "INSTALLING HARDWOOD FLOORING." <br />B. CONCRETE SUBSTRATES: VERIFY THAT SLABS ARE DRY ACCORDING TO TEST METHODS <br />RECOMMENDED BY FLOORING MANUFACTURER OR, IF NONE, BY TEST METHODS IN <br />NOFMA'S "INSTALLING HARDWOOD FLOORING." <br />C. WHERE WOOD FLOORING IS ADHESIVELY ATTACHED TO CONCRETE SLABS, VERIFY THAT <br />SLABS ARE FREE OF CURING COMPOUNDS, SEALERS, HARDENERS, AND OTHER MATERIALS <br />THAT MAY INTERFERE WITH ADHESIVE BOND. <br />D. PROVIDE EXPANSION SPACE AT WALLS AND OTHER OBSTRUCTIONS AND TERMINATIONS OF <br />FLOORING OF NOT LESS THAN DIRECTED BY MANUFACTURER. <br />E. ENGINEERED -WOOD FLOORING: SET IN ADHESIVE PER MANUFACTURER'S INSTRUCTIONS. <br />F. WOOD TRIM: NAIL BASEBOARD TO WALL AND NAIL SHOE MOLDING OR OTHER TRIM TO <br />BASEBOARD; DO NOT NAIL TO FLOORING. <br />G. PROVIDE EXPANSION SPACE AT WALLS AND OTHER OBSTRUCTIONS AND TERMINATIONS OF <br />FLOORING <br />E. CLEANING AND PROTECTION <br />1. COVER WOOD FLOORING BEFORE AND AFTER FINISHING DURING REMAINDER OF <br />CONSTRUCTION PERIOD. USE HEAVY KRAFT-PAPER OR OTHER SUITABLE COVERING. <br />DO NOT USE PLASTIC SHEET OR FILM THAT COULD CAUSE CONDENSATION. <br />2. CLEAN AND BUFF PER MANUFACTURE'S RECOMMENDATION IMMEDIATE <br />LY PRIOR TO <br />BUILDING OCCUPANCY. <br />095300 ACOUSTICAL PANEL CEILINGS <br />A. REFERENCES: <br />1. AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM): <br />a. C635 - METAL SUSPENSION SYSTEMS FOR ACOUSTIC TILE AND LAY -IN PANEL CEILINGS. <br />U C CE GS <br />b. C636 -RECOMMENDED PRACTICE FOR THE INSTALLATION OF METAL CEILING SUSPENSION <br />SYSTEMS FOR ACOUSTIC TILE AND LAY -IN PANELS. <br />B. QUALITY ASSURANCE: <br />1. CODES: CONFORM TO THE REQUIREMENTS OF THE AHJ, SEISMIC ZONE AS INDICATED <br />ON THE DRAWINGS, CISCA, AND THE REQUIREMENTS OF THE JURISDICTIONAL CODE <br />AUTHORITIES. <br />PRODUCTS: <br />1. ACOUSTICAL PANELS: AS INDICATED ON THE DRAWINGS. <br />2. SUSPENSION SYSTEM: EXPOSED T SYSTEM: ASTM C635, HEAVY DUTY CLASSIFICATION; <br />DIRECT HUNG; EXPOSED "T" DESIGN; FACTORY BAKED ON FINISH TO MATCH <br />ACOUSTICAL PANELS. FURNISH STABILIZER BARS, SPLICES, EDGE AND WALL <br />MOLDINGS, AND OTHER ITEMS AS NECESSARY TO COMPLETE SUSPENDED CEILING <br />GRID SYSTEM. <br />D. INSTALLATION: <br />1. INSTALL AFTER MAJOR ABOVE -CEILING WORK IS COMPLETE. <br />2. INSTALL SYSTEM IN ACCORDANCE WITH ASTM C636, IBC 1621.2.5 AND CISCA, THE <br />MANUFACTURER'S INSTRUCTIONS, AND AS SUPPLEMENTED IN THIS SECTION. <br />3. INSTALL GRID TO PRODUCE FINISHED CEILING TRUE TO LINES AND LEVELS INDICATED, <br />WITHIN THE SPECIFIED TOLERANCES. <br />4. INSTALL SUSPENSION SYSTEMS IN A MANNER TO SUPPORT ALL SUPERIMPOSED LOADS, <br />WITH MAXIMUM PERMISSIBLE DEFLECTION OF 1/270 OF SPAN. AT LOCATIONS WHERE <br />PARTITIONS EXTEND TO CEILING, ONLY, INSTALL SUPPLEMENTARY DIAGONAL BRACING <br />TO STRUCTURE AT MAXIMUM 8'-0" O.C. ALONG LENGTH OF PARTITION, AND ABOVE <br />EACH DOOR HINGE AND STRIKE JAMB <br />5. HANG SYSTEM INDEPENDENT OF WALLS, COLUMNS, DUCTS, PIPES AND CONDUIT. <br />WHERE DUCTS OR OTHER EQUIPMENT PREVENT THE REGULAR SPACING OF HANGERS, <br />PROVIDE SECONDARY CARRYING MEMBERS FOR INDIRECT SUPPORT OF THE <br />SUSPENSION SYSTEM, OR REINFORCE THE NEAREST ADJACENT HANGERS AND <br />RELATED CARRYING CHANNELS AS REQUIRED TO SPAN THE REQUIRED DISTANCE. <br />6. CENTER SYSTEM ON ROOM AXIS ACCORDING TO REFLECTED CEILING PLANS. <br />7. ANCHORAGE: <br />a. PROVIDE ALL ANCHORS REQUIRED FOR THE INSTALLATION OF THE CEILING SYSTEM <br />UNLESS OTHERWISE NOTED. <br />b. DO NOT FASTEN TO THE UPPER FLUTES OF METAL DECKING. DO NOT USE FASTENERS IN <br />STEEL DECK WHICH PENETRATE MORE THAN 1 INCH. <br />c. VERIFY LOCATION OF ALL CONDUIT IN POURED CONCRETE CONSTRUCTION BEFORE <br />MAKING ATTACHMENTS. <br />8. INSTALL EDGE MOLDING AT INTERSECTION OF CEILING AND VERTICAL SURFACES, <br />USING LONGEST PRACTICAL LENGTHS. MITER CORNERS. PROVIDE EDGE MOLDINGS AT <br />JUNCTIONS WITH OTHER INTERRUPTIONS. FABRICATE EDGE MOLDINGS TO FIT THE <br />SURFACES ENCOUNTERED. <br />i rr" <br />i <br />Ml ON <br />9. FORM EXPANSION JOINTS AS DETAILED. MAINTAIN VISUAL CLOSURE. <br />10. FIT ACOUSTIC LAY -IN PANELS IN PLACE, FREE FROM DAMAGED EDGES OR OTHER <br />DEFECTS DETRIMENTAL TO APPEARANCE AND FUNCTION. FIT BORDER UNITS NEATLY <br />AGAINST ABUTTING SURFACES. SCRIBE AND MILL RECESSED REGULAR EDGE INTO <br />PARTIAL BORDER UNITS SUPPORTED AT EDGE BY WALL MOLDING. <br />11. ADJUST SAGS OR TWISTS WHICH DEVELOP IN THE CEILING SYSTEM AND REPLACE <br />PARTS WHICH ARE DAMAGED OR DEFECTIVE. <br />12. INSTALL HOLD-DOWN CLIPS TO RETAIN PANELS TIGHT TO GRID SYSTEM WITHIN 20 FT <br />OF AN EXTERIOR DOOR. <br />13. TOLERANCES: <br />14. VARIATION FROM FLAT AND LEVEL SURFACE: 1/8 INCH IN 12 FT. <br />15. VARIATION FROM PLUMB OF GRID MEMBERS CAUSED BY ECCENTRIC LOADS: TWO <br />DEGREES MAXIMUM. <br />E. PERFORMANCE <br />1. SEISMIC PERFORMANCE: ACOUSTICAL CEILING SHALL WITHSTAND THE EFFECTS OF <br />EARTHQUAKE MOTIONS DETERMINED ACCORDING TO ASCE/SEI 7. <br />2. SURFACE -BURNING CHARACTERISTICS: COMPLY WITH ASTM E 84; TESTING BY A <br />QUALIFIED TESTING AGENCY. IDENTIFY PRODUCTS WITH APPROPRIATE MARKINGS OF <br />APPLICABLE TESTING AGENCY. <br />3. FLAME -SPREAD INDEX: COMPLY WITH ASTM E 1264 FOR CLASS A MATERIALS. <br />4. SMOKE -DEVELOPED INDEX: [50] [450] OR LESS. <br />5. FIRE -RESISTANCE RATINGS: COMPLY WITH ASTM E 119; TESTING BY A QUALIFIED <br />TESTING AGENCY. IDENTIFY PRODUCTS WITH APPROPRIATE MARKINGS OF APPLICABLE <br />TESTING AGENCY. <br />6. SEISMIC STRUTS: MANUFACTURER'S STANDARD COMPRESSION STRUTS DESIGNED TO <br />ACCOMMODATE LATERAL FORCES. <br />7. SEISMIC CLIPS: MANUFACTURER'S STANDARD SEISMIC CLIPS DESIGNED AND SPACED <br />TO SECURE ACOUSTICAL TILES IN -PLACE. <br />096500 RESILIENT FLOORING <br />A. SUMMARY: <br />1. RESILIENT SHEET FLOORING. <br />2. RESILIENT BASE. <br />B. SUBMITTALS: <br />1. SUBMIT PRODUCT LITERATURE FOR EACH PRODUCT PROPOSED, INCLUDING BASE, <br />RESILIENT FLOORING, TRANSITION STRIPS, AND ADHESIVES. <br />2. SUBMITTALS: SUBMIT SAMPLES OF EACH TYPE OF RESILIENT FLOORING, AND EACH <br />TYPE OF RUBBER BASE FOR COLOR SELECTION BY THE INTERIOR DESIGNER. <br />C. MATERIALS: <br />1. RESILIENT SHEET FLOORING: AS INDICATED ON THE DRAWINGS <br />2. RUBBER BASE: <br />a. RESILIENT BASE: ASTM F1861, TYPE TPR THERMOPLASTIC RUBBER; 1/8 INCH THICK; ROLL <br />STOCK; COVED AND STRAIGHT BASE AS SPECIFIED; 4 INCH HEIGHT, UNLESS OTHERWISE <br />INDICATED ON THE DRAWINGS. <br />3. ACCESSORIES: <br />a. SUBFLOOR FILLER: PORTLAND CEMENT BASED LATEX FILLER, MIXED WITH WATER TO <br />PRODUCE A SELF LEVELING UNDERLAYMENT, OR CEMENTITIOUS PASTE, AS <br />APPROPRIATE TO PROJECT REQUIREMENTS. <br />b. ADHESIVES: TYPES RECOMMENDED BY RESILIENT FLOORING AND BASE MANUFACTURERS <br />FOR SPECIFIC APPLICATION. <br />c. TRANSITION STRIPS: VINYL; PRODUCTS AS INDICATED; COLOR AS SELECTED BY THE <br />ARCHITECT FROM MANUFACTURER'S STANDARD. <br />d. ALL OTHER MATERIALS NOT SPECIFICALLY DESCRIBED, BUT REQUIRED FOR A COMPLETE <br />AND PROPER INSTALLATION OF RESILIENT FLOORING, SHALL BE ONLY AS RECOMMENDED <br />BY THE MANUFACTURER OF THE MATERIAL TO WHICH IT IS APPLIED AND SHALL BE <br />SUBJECT TO THE APPROVAL OF THE ARCHITECT. <br />D. GENERAL RESILIENT FLOORING INSTALLATION REQUIREMENTS: <br />1. INSTALL SUBFLOOR FILLER TO FILL LOW SPOTS, CRACKS, CONSTRUCTION JOINTS, <br />HOLES AND OTHER DEFECTS, AND AS REQUIRED TO ADJUST LEVEL TO MEET <br />ADJACENT FINISHES. FEATHER TO MAXIMUM SLOPE OF 1/8 INCH IN 3 FEET; FLOAT TO <br />SMOOTH, FLAT, HARD SURFACE. PROHIBIT TRAFFIC OVER FILLER. <br />2. INSTALL ALL RESILIENT FLOORING WHERE SCHEDULED IN ACCORDANCE WITH THE <br />MANUFACTURER'S RECOMMENDATIONS. <br />3. UNLESS INDICATED OTHERWISE, INSTALL RESILIENT FLOORING WITH JOINTS AND <br />SEAMS AS INDICATED ON THE DRAWINGS. <br />4. TERMINATE RESILIENT FLOORING AT CENTERLINE OF DOOR AT DOOR OPENINGS <br />WHERE ADJACENT FLOOR FINISH IS DISSIMILAR, AND WHERE NO THRESHOLD IS <br />INDICATED. <br />5. INSTALL EDGE STRIPS AT UNPROTECTED OR EXPOSED EDGES WHERE FLOORING <br />TERMINATES. <br />6. SCRIBE FLOORING TO WALLS, COLUMNS, CABINETS, FLOOR OUTLETS AND OTHER <br />APPURTENANCES TO PRODUCE TIGHT JOINTS. <br />7. CLEAN SUBSTRATE. SPREAD CEMENT EVENLY IN QUANTITY RECOMMENDED BY <br />MANUFACTURER TO ENSURE ADHESION OVER ENTIRE AREA OF INSTALLATION. SPREAD <br />ONLY ENOUGH ADHESIVE TO PERMIT INSTALLATION OF FLOORING BEFORE INITIAL SET, <br />8. SET FLOORING IN PLACE, PRESS WITH HEAVY ROLLER TO ENSURE FULL ADHESION. <br />9. SEAL JOINT BETWEEN FLOORING AND ADJACENT MATERIALS AT RESTROOMS, <br />BATHROOMS, KITCHENS, AND OTHER MOIST AREAS WITH CLEAR SILICONE SEALANT. <br />E. SPECIAL REQUIREMENTS FOR SHEET FLOORING: <br />1. INSTALL SHEET FLOORING TO A MINIMUM 1/3 FULL MATERIAL WIDTH, WITH LENGTH OF <br />SHEET PARALLEL TO LENGTH OF ROOM. WHERE CUTTING IS REQUIRED, DOUBLE CUT <br />AND WELD AS SPECIFIED. TRIM IN ACCORDANCE WITH MANUFACTURER'S <br />INSTRUCTIONS. <br />2. SEAMS IN ACCORDANCE WITH THE MANUFACTURER'S PRINTED INSTRUCTIONS. <br />3. UNLESS INDICATED OTHERWISE, LAY FLOORING WITH SEAMS PARALLEL TO BUILDING <br />LINES TO PRODUCE MINIMUM NUMBER OF SEAMS. <br />4. SPECIAL FLASHED COVED BASE REQUIREMENTS: <br />a. PROVIDE COVE FILLET AT INTERSECTION OF FLOOR AND WALL TO EASE TRANSITION. <br />b. MITER CUT, FIT, AND HEAT WELD ALL SEAMS, JOINTS, PENETRATIONS, AND TRANSITIONS. <br />EXTEND FLOORING TO ELEVATION ABOVE FINISHED FLOOR LEVEL AS INDICATED. <br />c. CUT TOP EXPOSED EDGE STRAIGHT AND LEVEL. <br />d. CAP TOP EDGE WITH CAP TRIM. MITER ALL TRIM CORNER JOINTS. INSTALL TRIM IN <br />MAXIMUM PRACTICAL LENGTHS WITH NO PIECE SHORTER THAN 18 INCHES FOR <br />CONTINUOUS RUNS LONGER THAN 18 INCHES. <br />F. RUBBER BASE INSTALLATION: <br />1. ADHESIVELY INSTALL RESILIENT BASE TIGHTLY TO WALL AND FLOOR SURFACES IN <br />ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. <br />2. FIT JOINTS TIGHT, VERTICAL, AND IN ACCURATE ALIGNMENT. INSTALL BASE IN MAXIMUM <br />LENGTHS, WITH MINIMUM NUMBER OF JOINTS IN EACH RUN, NO SECTION MAY BE <br />SHORTER THAN 48 INCHES, EXCEPT AS REQUIRED BY WALL CONDITIONS. <br />3. INSTALL BASE TO WALLS, COLUMNS, AND CASEWORK TOE KICKS IN ALL AREAS WHERE <br />RESILIENT BASE IS SCHEDULED. <br />4. MITER OR COPE INSIDE CORNERS FOR ACCURATE FIT. SCRIBE AND FIT TO DOOR <br />FRAMES AND OTHER OBSTRUCTIONS. <br />5. OUTSIDE CORNERS: <br />a. SCORE BACK OF BASE MATERIAL WITH GROOVING TOOL AND ACCURATELY ALIGN TO <br />CORNER. <br />b. FIRMLY ADHERE TO WALL AT BOTH SIDES OF CORNER, WITH NO VISIBLE GAPS AT TOP OF <br />BASE. <br />c. STRETCH TOE OF COVED BASE FOR SMOOTH TRANSITION AROUND CORNER, WITH TOE IN <br />UNIFORM CONTACT WITH THE FINISH FLOORING. <br />6. REMOVE EXCESS ADHESIVE FROM SURFACES WITHOUT DAMAGE. <br />G. CLEANING <br />1. REMOVE EXCESS ADHESIVE FROM FLOOR, BASE, AND WALL SURFACES WITHOUT <br />DAMAGE. <br />2. CLEAN BASE AND FLOOR IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. <br />096813 CARPETING <br />A. QUALITY ASSURANCE: CARPET INSTALLER SHALL HAVE MINIMUM OF 3 YEARS EXPERIENCE <br />IN CARPET INSTALLATIONS OF SIMILAR SIZE AND SCOPE. <br />B. WARRANTY: FURNISH MANUFACTURER'S STANDARD 5-YEAR WARRANTY AGAINST WEAR <br />AND DETERIORATION. <br />C. MATERIALS: <br />1. CARPET: AS SCHEDULED ON THE DRAWINGS. <br />2. PAD: AS SCHEDULED ON THE DRAWINGS. <br />3. WALK -OFF MAT: AS SCHEDULED ON THE DRAWINGS. <br />4. ACCESSORIES: <br />a. CARPET GRIPPERS: ROBERTS ARCHITECTURAL "22-333", OR APPROVED. <br />b. PAD TAPE: NON -PAPER TAPE RECOMMENDED BY PAD MANUFACTURER. <br />c. EDGE STRIPS: REDUCER STRIPS; SIZE AND CONFIGURATION AS APPROPRIATE FOR <br />CONDITIONS; COLOR AS SELECTED BY ARCHITECT FROM MANUFACTURER'S STANDARD <br />LINE. <br />d. WALK -OFF MAT SCREED: SCHLUTER; ALUMINUM; PROFILE AS INDICATED ON THE <br />DRAWINGS, AND TO SUIT JOB CONDITIONS. <br />} -:00INt�, <br />e. ADHESIVES: TYPE AS RECOMMENDED BY CARPET, MAT OR SCREED MANUFACTURER FOR <br />INTENDED USE. USE WATERPROOF ADHESIVE AT WALK -OFF MAT. <br />f. LATEX UNDERLAYMENT: WHITE PREMIX LATEX FILLER. <br />g. BACKING: AS INDICATED ON THE DRAWINGS. <br />D. PREPARATION: <br />1. CLEAN FLOORS OF DUST, DIRT, SOLVENTS, OIL, GREASE, PAINT, PLASTER, AND OTHER <br />SUBSTANCES WHICH WOULD BE DETRIMENTAL TO THE PROPER PERFORMANCE OF <br />ADHESIVE AND CARPET. <br />2. FILL LOW SPOTS AND CRACKS OVER 1/8 INCH IN WIDTH WITH LATEX UNDERLAYMENT. <br />E. INSTALLATION: <br />1. INSTALL CARPETS IN STRICT ACCORDANCE WITH THE MANUFACTURER'S <br />RECOMMENDATIONS. <br />2. VERIFY MATCHING OF CARPET PRIOR TO CUTTING AND ENSURE THAT THERE IS NO <br />VISIBLE VARIATION BETWEEN DYE LOTS. <br />3. CUT CARPET, WHERE REQUIRED IN A MANNER TO ALLOW PROPER SEAM AND PATTERN <br />MATCH. ENSURE CUTS ARE STRAIGHT AND TRUE AND UNFRAYED. <br />4. MAKE SEAMS STRAIGHT AND UNIFORM. <br />5. SEAMING SHALL BE BY HAND SEWING OR WITH HOT MELT TAPE METHODS. <br />6. DO NOT CHANGE RUN OF PILE IN ANY ONE ROOM. <br />7. ENSURE MONOLITHIC COLOR, PATTERN AND TEXTURE MATCH WITHIN EACH DISTINCT <br />ROOM. <br />8. INSTALL EDGING STRIPS WHERE CARPET TERMINATES AT OTHER FLOOR COVERINGS. <br />USE FULL LENGTH PIECES ONLY. BUTT TIGHT TO VERTICAL SURFACES. WHERE <br />SPLICING CANNOT BE AVOIDED, BUTT ENDS TIGHT, FLUSH, AND ACCURATELY ALIGNED. <br />F. REMNANTS: UPON COMPLETION OF THE INSTALLATION, CONTACT THE ARCHITECT FOR <br />SELECTION OF CARPET REMAINING AFTER TRIMMING. CAREFULLY WRAP AND MARK <br />SEPARATELY THE SELECTED REMNANTS. REMOVE AND DISPOSE OF REMAINDER AT A <br />LEGAL OFF -SITE LOCATION. <br />G.CLEANUP: <br />1. THE PREMISES SHALL BE KEPT FREE FROM UNNECESSARY ACCUMULATION OF TOOLS, <br />EQUIPMENT AND SURPLUS MATERIALS DURING THE PROGRESS OF THE WORK. <br />2. REMOVE THREADS WITH SHARP SCISSORS. REMOVE SPOTS WITH MANUFACTURER'S <br />RECOMMENDED SPOT REMOVER. <br />3. THOROUGHLY POWER VACUUM ENTIRE SURFACE USING EQUIPMENT WITH MOTOR <br />DRIVEN BRUSHES. <br />097733 REINFORCED PLASTIC PANEL WALL COVERINGS <br />A.SUMMARY: FIBERGLASS REINFORCED POLYESTER PANEL (FRP) WALL COVERING. <br />B. SUBMITTALS: PRODUCT DATA, INCLUDING ADHESIVES AND SEALANTS. <br />C.PANEL SYSTEM COMPONENTS: <br />1. PANEL MATERIAL: <br />a. MARLITE (AS NOTED IN DRAWINGS). <br />b. PANEL TYPE: AS SCHEDULED IN THE FINISH LEGEND. <br />c. THICKNESS: 3/32 INCH. <br />d. SIZE: 48 INCHES X LENGTH REQUIRED FOR CONDITIONS INDICATED. <br />e. FIRE RATING: MAXIMUM 25/450 FLAME SPREAD / SMOKE DEVELOPED IN ACCORDANCE <br />WITH ASTM E84. <br />2. MOLDINGS: MANUFACTURER'S STANDARD PVC CAP, CORNER, AND DIVISION MOLDINGS; <br />COLOR TO MATCH PANELS. OMIT BOTTOM TRIM WHERE PANEL ABUTS FLASH COVED <br />BASE. <br />3. PANEL AND MOLDING INSTALLATION ADHESIVE: AS RECOMMENDED BY THE FRP PANEL <br />MANUFACTURER. <br />4. SEALANT: FLEXIBLE WATERPROOF SILICONE SEALANT FOR BEDDING PANEL EDGES; <br />WHITE COLOR. <br />D. INSTALLATION <br />1. CUTTING AND FITTING <br />a. CUT PANELS ACCURATELY TO SIZE WITH PROPER ALLOWANCE FOR EXPANSION AND <br />MOLDINGS. <br />b. SAND OR FILE ALL EDGES SMOOTH WITHOUT CHIPPING. <br />c. CUT OPENINGS FOR PENETRATIONS IN ACCURATE LOCATION WITH APPROXIMATE <br />1/8-INCH CLEARANCE AROUND PENETRATIONS. <br />2. ESTABLISH CENTERLINE OF EACH DISTINCT FLAT AREA TO BE COVERED. TRIM DIVISION <br />MOLDINGS TO MATE WITH BASE MOLDINGS; INSTALL IN SOLID BED OF ADHESIVE, <br />EITHER ON CENTERLINE, OR OFFSET 24 INCHES FROM CENTER, AS NECESSARY TO <br />MAXIMIZE PANEL WIDTHS AT CORNERS. MOLDING SHALL BE INSTALLED STRAIGHT AND <br />PLUMB. <br />3. CUT TOP CAP AND DIVISION OR CORNER MOLDINGS TO SHAPE, WITH EDGES TRIMMED <br />TO FIT TO ADJACENT MOLDINGS. <br />4. APPLY SEALANT INTO INSTALLED MOLDINGS IN SEQUENCE WITH PANEL INSTALLATION. <br />5. APPLY ADHESIVE TO BACKS OF PANELS IN ACCORDANCE WITH THE MANUFACTURER'S <br />RECOMMENDATIONS. <br />6. MAINTAIN LINES AND LEVELS OF PANEL EDGES AND MOLDINGS. <br />7. INSTALL PANELS TIGHT TO FLASH -COVED BASE TRIM. <br />8. ALLOW 1/8-INCH GAP BETWEEN TOP CAP, CORNER, OR DIVISION MOLDING POSTS, AND <br />PANEL EDGE; ALL EDGES SHALL BE FIRMLY BEDDED TO THE MOLDINGS IN SEALANT. <br />9. PROMPTLY REMOVE SEALANT SQUEEZE OUT WITH A DAMP CLOTH, AS WORK <br />PROGRESSES; REMOVE ADHESIVE WITH APPROPRIATE SOLVENT. <br />10. INSTALL SEALANT BEHIND FLANGES AND AT PENETRATIONS THROUGH PANELING, AND <br />BETWEEN TOP CAP OF PANEL AND SUBSTRATE. <br />11. CLEANING: REMOVE EXCESS ADHESIVE FROM FACE OF LAMINATE USING SOLVENT <br />RECOMMENDED B MANUFACTURER, <br />098100 ACOUSTIC INSULATION <br />A.SUMMARY: ACOUSTIC INSULATION AND SEALANTS. <br />B. MATERIALS: <br />1. MANUFACTURERS: JOHNS MANVILLE "SOUND CONTROL <br />BATTS", CERTAINTEED "GREENGUARD CERTIFIED", OWNS CORNING "SOUND CONTROL <br />BATTS." <br />2. ACOUSTIC INSULATION: ASTM C665, TYPE I; UNFACED GLASS FIBER BATTS, BLANKETS, <br />OR ROLLS; MINIMUM FIRE HAZARD CLASSIFICATION RATING OF 25/50 PER ASTM E84; <br />MINIMUM 3-INCH THICK, UNLESS REQUIRED OTHERWISE TO MEET THE STC <br />REQUIREMENTS INDICATED OR SPECIFIED; WIDTHS TO FRICTION -FIT BETWEEN STUDS, <br />WHERE INDICATED FOR INSTALLATION IN STUD WALLS. <br />3. ACOUSTICAL SEALANT: NON -HARDENING, NON -SKINNING, FOR USE IN CONJUNCTION <br />WITH GYPSUM BOARD; SIMILAR TO USG "ACOUSTICAL SEALANT." <br />4. ACCESSORIES: FURNISH OTHER ACCESSORIES SUCH AS FASTENERS AND RETAINERS, <br />NOT SPECIFICALLY DESCRIBED, BUT REQUIRED FOR A COMPLETE INSTALLATION. <br />C.INSULATION: <br />1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS, AND AS INDICATED. <br />2. TRIM INSULATION NEATLY TO FIT SPACES..INSTALL WITHOUT GAPS OR VOIDS. <br />D. SEAL PENETRATIONS THROUGH ACOUSTICAL ASSEMBLIES, EXCEPT FOR <br />PENETRATIONS IN FIRE RATED CONSTRUCTION TO RECEIVE FIRESTOPPING. <br />099000 PAINTING AND COATING <br />A.SUMMARY: SITE APPLIED PAINT COATINGS, EXCEPT AS OTHERWISE NOTED. <br />B. QUALITY ASSURANCE: <br />1. APPLICATOR: COMPANY SPECIALIZING IN COMMERCIAL PAINTING AND FINISHING WITH <br />A MINIMUM OF THREE YEARS DOCUMENTED EXPERIENCE. <br />2. VISUAL STANDARDS: EACH DISTINCT AREA OF THE FINISHED WORK SHALL BE FREE OF <br />VARIATIONS IN COLOR AND SHEEN, ORANGE PEEL, RUNS, SAGS, BLISTERING, <br />CHECKING, CRACKING, SCRATCHES, DUST, DIRT, BUGS, AND OTHER CONTAMINANTS. <br />C.SITE CONDITIONS: <br />1. WEATHER CONDITIONS: <br />a. DO NO EXTERIOR WORK ON UNPROTECTED SURFACES WHEN RAINING, OR OTHER <br />MOISTURE IS PRESENT OR EXPECTED, OR BEFORE APPLIED PAINTS CAN DRY OR ATTAIN <br />PROPER CURE. <br />b. ALLOW WETTED SURFACES TO DRY AND ATTAIN TEMPERATURES AND CONDITION <br />SPECIFIED HEREINAFTER BEFORE PROCEEDING WITH PREVIOUSLY STARTED WORK. <br />2. TEMPERATURE: <br />a. DO NO PAINTING WORK WHEN SURFACE AND AIR TEMPERATURES ARE BELOW 40 <br />DEGREES F OR BELOW THOSE TEMPERATURES RECOMMENDED BY THE MANUFACTURER <br />FOR THE MATERIAL TYPE USED. <br />b. MINIMUM TEMPERATURES FOR LATEX FINISHES: 45 DEGREES F FOR INTERIOR WORK AND <br />50 DEGREES F. FOR EXTERIOR WORK, UNLESS APPROVED OTHERWISE. <br />3. LIGHTING: MAINTAIN A LIGHTING LEVEL OF MINIMUM 50 FOOT-CANDLES ON THE <br />SURFACES TO BE PAINTED OR FINISHED. <br />4. VENTILATION: PROVIDE ADEQUATE CONTINUOUS VENTILATION. <br />D. MAINTENANCE: <br />1. FURNISH OVERAGE OF PAINT MATERIALS EQUAL TO 10 PERCENT MINIMUM OF <br />QUANTITY OF EACH PAINT AND TRANSPARENT FINISH SYSTEM COMPONENT, COLOR <br />AND SHEEN REQUIRED FOR THE WORK, BUT FURNISH NOT MORE THAN FIVE FULL ONE <br />GALLON CANS, NOR LESS THAN TWO FULL ONE QUART CANS, OF EACH TYPE. <br />OVERRUNS IN EXCESS OF FIVE GALLONS MAY BE FURNISHED TO T-MOBILE AT THE <br />CONTRACTOR'S OPTION. OVERAGE SHALL BE TAKEN FROM THE BATCH MIX FURNISHED <br />FOR THE WORK. OVERAGE SHALL BE FURNISHED IN COMPLETELY FILLED, PROPERLY <br />LABELED, SEALED CANS. <br />T Mobile <br />12920 SE 38th STREET <br />BELLEVUE, WA 98006 <br />www.T-Mobile.com <br />COPYRIGHT NOTICE <br />THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO <br />COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF <br />THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED JANUARY 2003, THE PROTECTION <br />INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND <br />COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH <br />PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS <br />MAY RESULT IN CESSATION OF CONSTRUCTION, BUILDING SEIZURE, AND/OR <br />MONETARY LIABILITY. <br />ARCHITECT: <br />rmUzioN <br />9096 EAST BAHIA DRIVE <br />SUITE 103 <br />SCOTTSDALE, AZ 85260 <br />DESIGN@FUZIONVE.COM <br />VVVVVV.FUZIONVE.COM <br />VENDOR PROJECT NO: 21.11.212680 <br />oo LOUas �,, ✓ ..v <br />OS-1 <br />(1100 4 <br />Sr�REo <br />02/10/2022 <br />CONSULTING ENGINEER: <br />N <br />W <br />Lu <br />wv <br />Q r <br />Lo <br />W > M <br />C� J J <br />J = � <br />V J <br />m <br />J. J <br />LJ.IJ= <br />0 <br />CO <br />o.qa <br />JC-4 W <br />m ti N <br />J <br />J <br />,Q <br />V <br />DATE: February 5, 2022 <br />SCALE: AS NOTED <br />DRAWN BY: LEO V. <br />SAP NUMBER: <br />4SIR <br />CORPORATE TENANT REBUILD <br />LDC <br />SHEET TITLE: <br />SPECIFICATIONS <br />SHEET NUMBER: <br />4 <br />3 <br />M <br />1 <br />A705 <br />