<br />16.a. CHEMICAL -RESISTANT EPDXY GROUT: ANSI A118.3, COLOR AS INDICATED.
<br />16.b. PROVIDE PRODUCT CAPABLE OF RESISTING CONTINUOUS AND INTERMITTENT EXPOSURE
<br />TO TEMPERATURES OF UP TO 140 DEG F (60 DEG C) AND 212 DEG F (100 DEG C),
<br />RESPECTIVELY, AS CERTIFIED BY MORTAR MANUFACTURER FOR INTENDED USE.
<br />17. ELASTOMERIC SEALANTS: PROVIDE MANUFACTURER'S STANDARD CHEMICALLY
<br />CURING, ELASTOMERIC SEALANTS OF BASE POLYMER AND CHARACTERISTICS
<br />INDICATED THAT COMPLY WITH APPLICABLE REQUIREMENTS OF DIVISION 7 SECTION
<br />"JOINT SEALANTS."
<br />17.a. ONE -PART, MILDEW -RESISTANT SILICONE SEALANT: ASTM C 920; TYPE S; GRADE NS;
<br />CLASS 25; USES NT, G, A, AND, AS APPLICABLE TO NONPOROUS JOINT SUBSTRATES
<br />INDICATED, 0; FORMULATED WITH FUNGICIDE.
<br />18. CEMENTITIOUS BACKER UNITS: PROVIDE PRODUCTS COMPLYING WITH ANSI A118.9, OF
<br />THICKNESS AND WIDTH INDICATED, AND IN MAXIMUM LENGTHS AVAILABLE TO MINIMIZE
<br />END -TO -END BUTT JOINTS.
<br />19. MISCELLANEOUS MATERIALS: AS FOLLOWS:
<br />a. TROWELABLE UNDERLAYMENTS AND PATCHING COMPOUNDS: LATEX -MODIFIED,
<br />PORTLAND-CEMENT-BASED FORMULATION PROVIDED OR APPROVED BY MANUFACTURER
<br />OF TILE -SETTING MATERIALS FOR INSTALLATIONS INDICATED.
<br />b. METAL EDGE STRIPS: WHITE -ZINC -ALLOY TERRAZZO STRIPS, 1/8 INCH (3,2 MM) WIDE AT
<br />TOP EDGE WITH INTEGRAL PROVISION FOR ANCHORAGE TO MORTAR BED OR SUBSTRATE,
<br />UNLESS OTHERWISE INDICATED.
<br />20. WATERPROOF MEMBRANE INSTALLATION: (COORDINATE WITH LANDLORD
<br />REQUIREMENTS)
<br />a. INSTALL WATERPROOF MEMBRANES IN STRICT ACCORDANCE WITH MANUFACTURER'S
<br />INSTALLATION INSTRUCTIONS.
<br />C.PREPARATION: CLEAN SUBSTRATE SURFACES FREE OF GREASE, DIRT, DUST, ORGANIC
<br />IMPURITIES, CURING AGENTS, AND OTHER MATERIALS THAT WOULD IMPAIR BOND.
<br />CLEAN FLOORS WITH "BLAST -TRACK" UNIT IF NECESSARY.
<br />1. SLAB LEVELING: (COORDINATE WITH LANDLORD REQUIREMENTS)
<br />2. PRIOR TO INSTALLATION OF THINSET FLOOR TILE, WHERE LOCAL IRREGULARITIES IN
<br />THE SUBSTRATE SURFACE WOULD PREVENT LEVEL INSTALLATION OF THE TILE, THE
<br />SUBSTRATE SHALL BE BROUGHT TO PLANE SURFACE WITH VARIATIONS NOT TO
<br />EXCEED 1/8 INCH IN 4 FEET (CUMULATIVE) AND 1/4 INCH IN 10 FEET (NON -CUMULATIVE).
<br />SMOOTH ALL ABRUPT CHANGES IN PLANE.
<br />3. USE THINSET MORTAR OR OTHER FILLER FOR SLAB LEVELING. OTHER FILLERS ARE
<br />SUBJECT TO ENDORSEMENT BY THE SETTING MORTAR MANUFACTURER.
<br />4. SCREED OR FLOAT TO APPROPRIATE THICKNESS AND SPECIFIED SURFACE
<br />TOLERANCE. ALLOW TO SET PRIOR TO PROCEEDING WITH INSTALLATION, DO NOT
<br />EXCEED THE MAXIMUM THICKNESSES FOR THIN BED MORTAR AS RECOMMENDED BY
<br />THE MANUFACTURER.
<br />D. EXECUTION
<br />1. PROVIDE CONCRETE SUBSTRATES FOR TILE FLOORS INSTALLED WITH DRY -SET OR
<br />LATEX-PORTLAND CEMENT MORTARS THAT COMPLY WITH FLATNESS TOLERANCES
<br />SPECIFIED IN REFERENCED ANSI A108 SERIES OF TILE INSTALLATION STANDARDS FOR
<br />INSTALLATIONS INDICATED.
<br />a. USE TROWELABLE LEVELING AND PATCHING COMPOUNDS PER TILE -SETTING MATERIAL
<br />MANUFACTURER'S WRITTEN INSTRUCTIONS TO FILL CRACKS, HOLES, AND DEPRESSIONS.
<br />b. REMOVE PROTRUSIONS, BUMPS, AND RIDGES BY SANDING OR GRINDING.
<br />2. BLENDING: FOR TILE EXHIBITING COLOR VARIATIONS WITHIN THE RANGES SELECTED
<br />DURING SAMPLE SUBMITTALS, VERIFY THAT TILE HAS BEEN BLENDED IN THE FACTORY
<br />AND PACKAGED SO TILE UNITS TAKEN FROM ONE PACKAGE SHOW THE SAME RANGE IN
<br />COLORS AS THOSE TAKEN FROM OTHER PACKAGES AND MATCH APPROVED SAMPLES.
<br />3. ANSI TILE INSTALLATION STANDARDS: COMPLY WITH PARTS OF ANSI A108 SERIES OF
<br />TILE INSTALLATION STANDARDS IN "SPECIFICATIONS FOR INSTALLATION OF CERAMIC
<br />TILE" THAT APPLY TO TYPES OF SETTING AND GROUTING MATERIALS AND TO METHODS
<br />INDICATED OR REQUIRED.
<br />4. TCA INSTALLATION GUIDELINES: TCA'S "HANDBOOK FOR CERAMIC TILE INSTALLATION."
<br />COMPLY WITH TCA INSTALLATION METHODS INDICATED OR REQUIRED.
<br />5. EXTEND TILE WORK INTO RECESSES AND UNDER OR BEHIND EQUIPMENT AND
<br />FIXTURES TO FORM A COMPLETE COVERING WITHOUT INTERRUPTIONS, UNLESS
<br />OTHERWISE INDICATED. TERMINATE WORK NEATLY AT OBSTRUCTIONS, EDGES, AND
<br />CORNERS WITHOUT DISRUPTING PATTERN OR JOINT ALIGNMENTS.
<br />6. ACCURATELY FORM INTERSECTIONS AND RETURNS. PERFORM CUTTING AND DRILLING
<br />OF TILE WITHOUT MARRING VISIBLE SURFACES. CAREFULLY GRIND CUT EDGES OF TILE
<br />ABUTTING TRIM, FINISH, OR BUILT-IN ITEMS FOR STRAIGHT ALIGNED JOINTS. FIT TILE
<br />CLOSELY TO ELECTRICAL OUTLETS, PIPING, FIXTURES, AND OTHER PENETRATIONS SO
<br />PLATES, COLLARS, OR COVERS OVERLAP TILE.
<br />7. JOINTING PATTERN: LAY TILE IN GRID PATTERN, UNLESS OTHERWISE INDICATED. ALIGN
<br />JOINTS WHERE ADJOINING TILES ON FLOOR, BASE, WALLS, AND TRIM ARE THE SAME
<br />SIZE. LAY OUT TILE WORK AND CENTER TILE FIELDS IN BOTH DIRECTIONS IN EACH
<br />SPACE OR ON EACH WALL AREA. ADJUST TO MINIMIZE TILE CUTTING. PROVIDE
<br />UNIFORM JOINT WIDTHS, UNLESS OTHERWISE INDICATED.
<br />8. EXPANSION JOINTS: LOCATE EXPANSION JOINTS AND OTHER SEALANT -FILLED JOINTS,
<br />INCLUDING CONTROL, CONTRACTION, AND ISOLATION JOINTS, WHERE INDICATED
<br />DURING INSTALLATION OF SETTING MATERIALS, MORTAR BEDS, AND TILE. DO NOT
<br />SAW -
<br />CUT JOINTS AFTER INSTALLING TILES.
<br />9. LOCATE JOINTS IN TILE SURFACES DIRECTLY ABOVE JOINTS IN CONCRETE
<br />SUBSTRATES.
<br />10. PREPARE JOINTS AND APPLY SEALANTS TO COMPLY WITH REQUIREMENTS OF DIVISION
<br />7 SECTION "JOINT SEALANTS."
<br />11. GROUT TILE TO COMPLY WITH THE REQUIREMENTS OF THE FOLLOWING TILE
<br />INSTALLATION STANDARDS:
<br />12. FOR CERAMIC TILE GROUTS (SAND-PORTLAND CEMENT, DRY -SET, COMMERCIAL
<br />PORTLAND CEMENT, AND LATEX-PORTLAND CEMENT GROUTS), COMPLY WITH ANSI
<br />A108.10.
<br />13. FLOOR TILE INSTALLATION: INSTALL TILE TO COMPLY WITH REQUIREMENTS INDICATED,
<br />INCLUDING THOSE REFERENCING TCA INSTALLATION METHODS AND ANSI A108 SERIES
<br />OF TILE STANDARDS.
<br />14. JOINT WIDTHS: INSTALL TILE ON FLOORS WITH THE FOLLOWING JOINT WIDTHS:
<br />15. PAVER TILE: 1/4 INCH (6.35 MM).
<br />16. BACK BUTTERING: FOR INSTALLATIONS INDICATED, OBTAIN 100 PERCENT MORTAR
<br />COVERAGE BY COMPLYING WITH APPLICABLE SPECIAL REQUIREMENTS FOR BACK
<br />BUTTERING OF TILE IN REFERENCED ANSI A108 SERIES OF TILE INSTALLATION
<br />STANDARDS.
<br />17. METAL EDGE STRIPS: INSTALL AT LOCATIONS INDICATED OR WHERE EXPOSED EDGE
<br />OF TILE FLOORING MEETS CARPET, WOOD, OR OTHER FLOORING THAT FINISHES FLUSH
<br />WITH TOP OF TILE.
<br />18. WALL TILE INSTALLATION: INSTALL TYPES OF TILE DESIGNATED FOR WALL
<br />INSTALLATIONS TO COMPLY WITH MANUFACTURERS' REQUIREMENTS, INCLUDING
<br />THOSE REFERENCING TCA INSTALLATION METHODS AND ANSI SETTING -BED
<br />STANDARDS.
<br />19. JOINT WIDTHS: INSTALL TILE ON WALLS WITH THE FOLLOWING JOINT WIDTHS:
<br />20. WALL TILE: 1/16 INCH (1.6 MM).
<br />21. BACK BUTTERING: FOR INSTALLATIONS INDICATED, OBTAIN 100 PERCENT MORTAR
<br />COVERAGE BY COMPLYING WITH APPLICABLE SPECIAL REQUIREMENTS FOR BACK
<br />BUTTERING OF TILE IN REFERENCED ANSI A108 SERIES OF TILE INSTALLATION
<br />STANDARDS.
<br />22. CLEANING: ON COMPLETION OF PLACEMENT AND GROUTING, CLEAN ALL CERAMIC TILE
<br />SURFACES SO THEY ARE FREE OF FOREIGN MATTER. USE CLEANING MATERIALS AND
<br />METHODS THAT COMPLY WITH TILE AND GROUT MANUFACTURERS' WRITTEN
<br />INSTRUCTIONS.
<br />096403 WOOD FLOORING
<br />A.GENERAL
<br />1. RELATED DOCUMENTS: DRAWINGS AND GENERAL PROVISIONS OF CONTRACT,
<br />INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND DIVISION 1
<br />SPECIFICATION SECTIONS, APPLY TO THIS SECTION.
<br />2. SUMMARY
<br />a. ENGINEERED WOOD FLOOR.
<br />3. QUALITY ASSURANCE
<br />a. INSTALLER QUALIFICATIONS: INSTALLATION SHALL BE PERFORMED BY A FIRM
<br />EXPERIENCED IN THE APPLICATION OF SYSTEMS SIMILAR IN COMPLEXITY TO THOSE
<br />REQUIRED FOR THIS PROJECT. ADDITIONALLY, INSTALLERS SHALL BE IN POSSESSION OF
<br />THE MANUFACTURER'S INSTALLATION MANUAL AND ADHERE TO THE INSTRUCTIONS.
<br />b. HARDWOOD FLOORING: COMPLY WITH NOFMA GRADING RULES FOR SPECIES, GRADE,
<br />AND CUT. CERTIFICATION: PROVIDE FLOORING THAT CARRIES NOFMA GRADE STAMP ON
<br />EACH BUNDLE OR PIECE.
<br />c. MAPLE FLOORING: COMPLY WITH MFMA GRADING RULES FOR SPECIES, GRADE, AND CUT.
<br />CERTIFICATION: PROVIDE FLOORING THAT CARRIES MFMA MARK ON EACH BUNDLE OR
<br />PIECE.
<br />d. SOUTHERN PINE FLOORING: COMPLY WITH SPIB GRADING RULES FOR SPECIES, GRADE,
<br />AND CUT.
<br />e. SOFTWOOD FLOORING: COMPLY WITH WCLIB NO. 17 GRADING RULES FOR SPECIES,
<br />GRADE, AND CUT.
<br />4. PROJECT CONDITIONS
<br />nn Y11
<br />DI f! -
<br />'til
<br />}
<br />a. CONDITIONING: MAINTAIN RELATIVE HUMIDITY PLANNED FOR BUILDING OCCUPANTS AND
<br />AN AMBIENT TEMPERATURE BETWEEN 65 AND 75 DEG F (18 AND 24 DEG C) IN SPACES TO
<br />RECEIVE WOOD FLOORING FOR AT LEAST SEVEN DAYS BEFORE INSTALLATION, DURING
<br />INSTALLATION, AND FOR AT LEAST SEVEN DAYS AFTER INSTALLATION. AFTER
<br />POST -INSTALLATION PERIOD, MAINTAIN RELATIVE HUMIDITY AND AMBIENT TEMPERATURE
<br />PLANNED FOR BUILDING OCCUPANTS.
<br />b. MOVE WOOD FLOORING INTO SPACES WHERE IT WILL BE INSTALLED, AT LEAST SEVEN
<br />DAYS BEFORE INSTALLATION.
<br />c. FOR UNFINISHED PRODUCTS, OPEN SEALED PACKAGES TO ALLOW WOOD FLOORING TO
<br />ACCLIMATIZE.
<br />d. DO NOT INSTALL FLOORING UNTIL IT ADJUSTS TO THE RELATIVE HUMIDITY OF AND IS AT
<br />THE SAME TEMPERATURE AS THE SPACE WHERE IT IS TO BE INSTALLED.
<br />e. INSTALL FACTORY -FINISHED WOOD FLOORING AFTER OTHER FINISHING OPERATIONS,
<br />INCLUDING PAINTING, HAVE BEEN COMPLETED.
<br />B. PRODUCTS
<br />1. ENGINEERED -WOOD STRIP OR PLANK FLOORING PRODUCTS: AS INDICATED ON THE
<br />FINISH MATERIAL SCHEDULE. NO SUBSTITUTIONS. ENGINEERED -WOOD STRIP OR
<br />PLANK FLOORING: ANSI/HPVA LF.
<br />a. SPECIES: AS INDICATED ON DRAWINGS.
<br />b. GRADE: MANUFACTURERS STANDARD.
<br />c. THICKNESS: AS NOTED IN DRAWINGS
<br />d. CONSTRUCTION: AS NOTED IN DRAWINGS
<br />e. WIDTH: AS NOTED IN DRAWINGS
<br />f. LENGTH: AS NOTED IN DRAWINGS.
<br />g. EDGES: AS NOTED IN DRAWINGS.
<br />h. FINISH: AS NOTED IN DRAWINGS.
<br />2. ACCESSORY MATERIALS
<br />a. WOOD FLOORING ADHESIVE: MASTIC RECOMMENDED BY FLOORING AND ADHESIVE
<br />MANUFACTURERS FOR APPLICATION INDICATED. (NOT USED IN FLOATING FLOOR SYSTEM)
<br />b. FASTENERS: AS RECOMMENDED BY MANUFACTURER, BUT NOT LESS THAN THAT
<br />RECOMMENDED IN NOFMA'S "INSTALLING HARDWOOD FLOORING." (NOT USED IN
<br />FLOATING FLOOR SYSTEM)
<br />c. VAPOR RETARDER: ASTM D 4397, POLYETHYLENE SHEET NOT LESS THAN [6.0 MILS (0.15
<br />MM)] THICK.
<br />d. VERSASHIELD FLOORING UNDERLAYMENT WITH VERSASSHIELD SEAM TAPE INSTALLED
<br />PER MANUFACTURER INSTRUCTIONS.
<br />e. CORK EXPANSION STRIP: COMPOSITION CORK STRIP COMPLYING WITH FS HH-C-576, TYPE
<br />I-B, CLASS 2.
<br />f. WOOD FEATURE STRIPS: 2-INCH- (51-MM-) WIDE, SQUARE -EDGED WALNUT STRIPS
<br />FURNISHED IN LENGTHS AS LONG AS PRACTICAL AND IN THICKNESS TO MATCH WOOD
<br />FLOORING.
<br />g. METAL FEATURE STRIPS: 1/8-BY-1/8-INCH (3-BY-3-MM) SOLID BRASS STRIP, DESIGNED FOR
<br />INLAYING INTO ROUTED REVEAL IN WOOD FLOORING SURFACE.
<br />h. WOOD TRIM: IN SAME SPECIES AND GRADE AS WOOD FLOORING, UNLESS OTHERWISE
<br />INDICATED.
<br />i. WOOD BASE: 3/4 INCH (16 MM) THICK BY 2 INCHES (100 MM) HIGH.
<br />j. BASE SHOE MOLDING: 1/2 BY 3/4 INCH (13 BY 19 MM).
<br />k. THRESHOLD: TAPERED ON EACH SIDE AND ROUTED AT BOTTOM OF ONE SIDE TO
<br />ACCOMMODATE WOOD FLOORING.
<br />I. REDUCER STRIP: AS NOTED IN DRAWINGS.
<br />C. PREPARATION:
<br />1. CONCRETE SLABS: GRIND HIGH SPOTS AND FILL LOW SPOTS TO PRODUCE A MAXIMUM
<br />1/8-INCH (3-MM) DEVIATION IN ANY DIRECTION WHEN CHECKED WITH A 10-FOOT (3-M)
<br />STRAIGHT EDGE.
<br />2. USE TROWELABLE LEVELING AND PATCHING COMPOUNDS, ACCORDING TO
<br />MANUFACTURER'S WRITTEN INSTRUCTIONS, TO FILL CRACKS, HOLES, AND
<br />DEPRESSIONS IN SUBSTRATES.
<br />3. REMOVE COATINGS, INCLUDING CURING COMPOUNDS, AND OTHER SUBSTANCES ON
<br />SUBSTRATES THAT ARE INCOMPATIBLE WITH INSTALLATION ADHESIVES AND THAT
<br />CONTAIN SOAP, WAX, OIL, OR SILICONE, USING MECHANICAL METHODS RECOMMENDED
<br />BY MANUFACTURER. DO NOT USE SOLVENTS.
<br />4. BROOM OR VACUUM CLEAN SUBSTRATES TO BE COVERED IMMEDIATELY BEFORE
<br />PRODUCT INSTALLATION. AFTER CLEANING, EXAMINE SUBSTRATES FOR MOISTURE,
<br />ALKALINE SALTS, CARBONATION, OR DUST. PROCEED WITH INSTALLATION ONLY AFTER
<br />UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED.
<br />D. EXECUTION
<br />1. INSTALLATION
<br />A. COMPLY WITH FLOORING MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS, BUT
<br />NOT LESS THAN RECOMMENDATIONS IN NOFMA'S "INSTALLING HARDWOOD FLOORING."
<br />B. CONCRETE SUBSTRATES: VERIFY THAT SLABS ARE DRY ACCORDING TO TEST METHODS
<br />RECOMMENDED BY FLOORING MANUFACTURER OR, IF NONE, BY TEST METHODS IN
<br />NOFMA'S "INSTALLING HARDWOOD FLOORING."
<br />C. WHERE WOOD FLOORING IS ADHESIVELY ATTACHED TO CONCRETE SLABS, VERIFY THAT
<br />SLABS ARE FREE OF CURING COMPOUNDS, SEALERS, HARDENERS, AND OTHER MATERIALS
<br />THAT MAY INTERFERE WITH ADHESIVE BOND.
<br />D. PROVIDE EXPANSION SPACE AT WALLS AND OTHER OBSTRUCTIONS AND TERMINATIONS OF
<br />FLOORING OF NOT LESS THAN DIRECTED BY MANUFACTURER.
<br />E. ENGINEERED -WOOD FLOORING: SET IN ADHESIVE PER MANUFACTURER'S INSTRUCTIONS.
<br />F. WOOD TRIM: NAIL BASEBOARD TO WALL AND NAIL SHOE MOLDING OR OTHER TRIM TO
<br />BASEBOARD; DO NOT NAIL TO FLOORING.
<br />G. PROVIDE EXPANSION SPACE AT WALLS AND OTHER OBSTRUCTIONS AND TERMINATIONS OF
<br />FLOORING
<br />E. CLEANING AND PROTECTION
<br />1. COVER WOOD FLOORING BEFORE AND AFTER FINISHING DURING REMAINDER OF
<br />CONSTRUCTION PERIOD. USE HEAVY KRAFT-PAPER OR OTHER SUITABLE COVERING.
<br />DO NOT USE PLASTIC SHEET OR FILM THAT COULD CAUSE CONDENSATION.
<br />2. CLEAN AND BUFF PER MANUFACTURE'S RECOMMENDATION IMMEDIATE
<br />LY PRIOR TO
<br />BUILDING OCCUPANCY.
<br />095300 ACOUSTICAL PANEL CEILINGS
<br />A. REFERENCES:
<br />1. AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM):
<br />a. C635 - METAL SUSPENSION SYSTEMS FOR ACOUSTIC TILE AND LAY -IN PANEL CEILINGS.
<br />U C CE GS
<br />b. C636 -RECOMMENDED PRACTICE FOR THE INSTALLATION OF METAL CEILING SUSPENSION
<br />SYSTEMS FOR ACOUSTIC TILE AND LAY -IN PANELS.
<br />B. QUALITY ASSURANCE:
<br />1. CODES: CONFORM TO THE REQUIREMENTS OF THE AHJ, SEISMIC ZONE AS INDICATED
<br />ON THE DRAWINGS, CISCA, AND THE REQUIREMENTS OF THE JURISDICTIONAL CODE
<br />AUTHORITIES.
<br />PRODUCTS:
<br />1. ACOUSTICAL PANELS: AS INDICATED ON THE DRAWINGS.
<br />2. SUSPENSION SYSTEM: EXPOSED T SYSTEM: ASTM C635, HEAVY DUTY CLASSIFICATION;
<br />DIRECT HUNG; EXPOSED "T" DESIGN; FACTORY BAKED ON FINISH TO MATCH
<br />ACOUSTICAL PANELS. FURNISH STABILIZER BARS, SPLICES, EDGE AND WALL
<br />MOLDINGS, AND OTHER ITEMS AS NECESSARY TO COMPLETE SUSPENDED CEILING
<br />GRID SYSTEM.
<br />D. INSTALLATION:
<br />1. INSTALL AFTER MAJOR ABOVE -CEILING WORK IS COMPLETE.
<br />2. INSTALL SYSTEM IN ACCORDANCE WITH ASTM C636, IBC 1621.2.5 AND CISCA, THE
<br />MANUFACTURER'S INSTRUCTIONS, AND AS SUPPLEMENTED IN THIS SECTION.
<br />3. INSTALL GRID TO PRODUCE FINISHED CEILING TRUE TO LINES AND LEVELS INDICATED,
<br />WITHIN THE SPECIFIED TOLERANCES.
<br />4. INSTALL SUSPENSION SYSTEMS IN A MANNER TO SUPPORT ALL SUPERIMPOSED LOADS,
<br />WITH MAXIMUM PERMISSIBLE DEFLECTION OF 1/270 OF SPAN. AT LOCATIONS WHERE
<br />PARTITIONS EXTEND TO CEILING, ONLY, INSTALL SUPPLEMENTARY DIAGONAL BRACING
<br />TO STRUCTURE AT MAXIMUM 8'-0" O.C. ALONG LENGTH OF PARTITION, AND ABOVE
<br />EACH DOOR HINGE AND STRIKE JAMB
<br />5. HANG SYSTEM INDEPENDENT OF WALLS, COLUMNS, DUCTS, PIPES AND CONDUIT.
<br />WHERE DUCTS OR OTHER EQUIPMENT PREVENT THE REGULAR SPACING OF HANGERS,
<br />PROVIDE SECONDARY CARRYING MEMBERS FOR INDIRECT SUPPORT OF THE
<br />SUSPENSION SYSTEM, OR REINFORCE THE NEAREST ADJACENT HANGERS AND
<br />RELATED CARRYING CHANNELS AS REQUIRED TO SPAN THE REQUIRED DISTANCE.
<br />6. CENTER SYSTEM ON ROOM AXIS ACCORDING TO REFLECTED CEILING PLANS.
<br />7. ANCHORAGE:
<br />a. PROVIDE ALL ANCHORS REQUIRED FOR THE INSTALLATION OF THE CEILING SYSTEM
<br />UNLESS OTHERWISE NOTED.
<br />b. DO NOT FASTEN TO THE UPPER FLUTES OF METAL DECKING. DO NOT USE FASTENERS IN
<br />STEEL DECK WHICH PENETRATE MORE THAN 1 INCH.
<br />c. VERIFY LOCATION OF ALL CONDUIT IN POURED CONCRETE CONSTRUCTION BEFORE
<br />MAKING ATTACHMENTS.
<br />8. INSTALL EDGE MOLDING AT INTERSECTION OF CEILING AND VERTICAL SURFACES,
<br />USING LONGEST PRACTICAL LENGTHS. MITER CORNERS. PROVIDE EDGE MOLDINGS AT
<br />JUNCTIONS WITH OTHER INTERRUPTIONS. FABRICATE EDGE MOLDINGS TO FIT THE
<br />SURFACES ENCOUNTERED.
<br />i rr"
<br />i
<br />Ml ON
<br />9. FORM EXPANSION JOINTS AS DETAILED. MAINTAIN VISUAL CLOSURE.
<br />10. FIT ACOUSTIC LAY -IN PANELS IN PLACE, FREE FROM DAMAGED EDGES OR OTHER
<br />DEFECTS DETRIMENTAL TO APPEARANCE AND FUNCTION. FIT BORDER UNITS NEATLY
<br />AGAINST ABUTTING SURFACES. SCRIBE AND MILL RECESSED REGULAR EDGE INTO
<br />PARTIAL BORDER UNITS SUPPORTED AT EDGE BY WALL MOLDING.
<br />11. ADJUST SAGS OR TWISTS WHICH DEVELOP IN THE CEILING SYSTEM AND REPLACE
<br />PARTS WHICH ARE DAMAGED OR DEFECTIVE.
<br />12. INSTALL HOLD-DOWN CLIPS TO RETAIN PANELS TIGHT TO GRID SYSTEM WITHIN 20 FT
<br />OF AN EXTERIOR DOOR.
<br />13. TOLERANCES:
<br />14. VARIATION FROM FLAT AND LEVEL SURFACE: 1/8 INCH IN 12 FT.
<br />15. VARIATION FROM PLUMB OF GRID MEMBERS CAUSED BY ECCENTRIC LOADS: TWO
<br />DEGREES MAXIMUM.
<br />E. PERFORMANCE
<br />1. SEISMIC PERFORMANCE: ACOUSTICAL CEILING SHALL WITHSTAND THE EFFECTS OF
<br />EARTHQUAKE MOTIONS DETERMINED ACCORDING TO ASCE/SEI 7.
<br />2. SURFACE -BURNING CHARACTERISTICS: COMPLY WITH ASTM E 84; TESTING BY A
<br />QUALIFIED TESTING AGENCY. IDENTIFY PRODUCTS WITH APPROPRIATE MARKINGS OF
<br />APPLICABLE TESTING AGENCY.
<br />3. FLAME -SPREAD INDEX: COMPLY WITH ASTM E 1264 FOR CLASS A MATERIALS.
<br />4. SMOKE -DEVELOPED INDEX: [50] [450] OR LESS.
<br />5. FIRE -RESISTANCE RATINGS: COMPLY WITH ASTM E 119; TESTING BY A QUALIFIED
<br />TESTING AGENCY. IDENTIFY PRODUCTS WITH APPROPRIATE MARKINGS OF APPLICABLE
<br />TESTING AGENCY.
<br />6. SEISMIC STRUTS: MANUFACTURER'S STANDARD COMPRESSION STRUTS DESIGNED TO
<br />ACCOMMODATE LATERAL FORCES.
<br />7. SEISMIC CLIPS: MANUFACTURER'S STANDARD SEISMIC CLIPS DESIGNED AND SPACED
<br />TO SECURE ACOUSTICAL TILES IN -PLACE.
<br />096500 RESILIENT FLOORING
<br />A. SUMMARY:
<br />1. RESILIENT SHEET FLOORING.
<br />2. RESILIENT BASE.
<br />B. SUBMITTALS:
<br />1. SUBMIT PRODUCT LITERATURE FOR EACH PRODUCT PROPOSED, INCLUDING BASE,
<br />RESILIENT FLOORING, TRANSITION STRIPS, AND ADHESIVES.
<br />2. SUBMITTALS: SUBMIT SAMPLES OF EACH TYPE OF RESILIENT FLOORING, AND EACH
<br />TYPE OF RUBBER BASE FOR COLOR SELECTION BY THE INTERIOR DESIGNER.
<br />C. MATERIALS:
<br />1. RESILIENT SHEET FLOORING: AS INDICATED ON THE DRAWINGS
<br />2. RUBBER BASE:
<br />a. RESILIENT BASE: ASTM F1861, TYPE TPR THERMOPLASTIC RUBBER; 1/8 INCH THICK; ROLL
<br />STOCK; COVED AND STRAIGHT BASE AS SPECIFIED; 4 INCH HEIGHT, UNLESS OTHERWISE
<br />INDICATED ON THE DRAWINGS.
<br />3. ACCESSORIES:
<br />a. SUBFLOOR FILLER: PORTLAND CEMENT BASED LATEX FILLER, MIXED WITH WATER TO
<br />PRODUCE A SELF LEVELING UNDERLAYMENT, OR CEMENTITIOUS PASTE, AS
<br />APPROPRIATE TO PROJECT REQUIREMENTS.
<br />b. ADHESIVES: TYPES RECOMMENDED BY RESILIENT FLOORING AND BASE MANUFACTURERS
<br />FOR SPECIFIC APPLICATION.
<br />c. TRANSITION STRIPS: VINYL; PRODUCTS AS INDICATED; COLOR AS SELECTED BY THE
<br />ARCHITECT FROM MANUFACTURER'S STANDARD.
<br />d. ALL OTHER MATERIALS NOT SPECIFICALLY DESCRIBED, BUT REQUIRED FOR A COMPLETE
<br />AND PROPER INSTALLATION OF RESILIENT FLOORING, SHALL BE ONLY AS RECOMMENDED
<br />BY THE MANUFACTURER OF THE MATERIAL TO WHICH IT IS APPLIED AND SHALL BE
<br />SUBJECT TO THE APPROVAL OF THE ARCHITECT.
<br />D. GENERAL RESILIENT FLOORING INSTALLATION REQUIREMENTS:
<br />1. INSTALL SUBFLOOR FILLER TO FILL LOW SPOTS, CRACKS, CONSTRUCTION JOINTS,
<br />HOLES AND OTHER DEFECTS, AND AS REQUIRED TO ADJUST LEVEL TO MEET
<br />ADJACENT FINISHES. FEATHER TO MAXIMUM SLOPE OF 1/8 INCH IN 3 FEET; FLOAT TO
<br />SMOOTH, FLAT, HARD SURFACE. PROHIBIT TRAFFIC OVER FILLER.
<br />2. INSTALL ALL RESILIENT FLOORING WHERE SCHEDULED IN ACCORDANCE WITH THE
<br />MANUFACTURER'S RECOMMENDATIONS.
<br />3. UNLESS INDICATED OTHERWISE, INSTALL RESILIENT FLOORING WITH JOINTS AND
<br />SEAMS AS INDICATED ON THE DRAWINGS.
<br />4. TERMINATE RESILIENT FLOORING AT CENTERLINE OF DOOR AT DOOR OPENINGS
<br />WHERE ADJACENT FLOOR FINISH IS DISSIMILAR, AND WHERE NO THRESHOLD IS
<br />INDICATED.
<br />5. INSTALL EDGE STRIPS AT UNPROTECTED OR EXPOSED EDGES WHERE FLOORING
<br />TERMINATES.
<br />6. SCRIBE FLOORING TO WALLS, COLUMNS, CABINETS, FLOOR OUTLETS AND OTHER
<br />APPURTENANCES TO PRODUCE TIGHT JOINTS.
<br />7. CLEAN SUBSTRATE. SPREAD CEMENT EVENLY IN QUANTITY RECOMMENDED BY
<br />MANUFACTURER TO ENSURE ADHESION OVER ENTIRE AREA OF INSTALLATION. SPREAD
<br />ONLY ENOUGH ADHESIVE TO PERMIT INSTALLATION OF FLOORING BEFORE INITIAL SET,
<br />8. SET FLOORING IN PLACE, PRESS WITH HEAVY ROLLER TO ENSURE FULL ADHESION.
<br />9. SEAL JOINT BETWEEN FLOORING AND ADJACENT MATERIALS AT RESTROOMS,
<br />BATHROOMS, KITCHENS, AND OTHER MOIST AREAS WITH CLEAR SILICONE SEALANT.
<br />E. SPECIAL REQUIREMENTS FOR SHEET FLOORING:
<br />1. INSTALL SHEET FLOORING TO A MINIMUM 1/3 FULL MATERIAL WIDTH, WITH LENGTH OF
<br />SHEET PARALLEL TO LENGTH OF ROOM. WHERE CUTTING IS REQUIRED, DOUBLE CUT
<br />AND WELD AS SPECIFIED. TRIM IN ACCORDANCE WITH MANUFACTURER'S
<br />INSTRUCTIONS.
<br />2. SEAMS IN ACCORDANCE WITH THE MANUFACTURER'S PRINTED INSTRUCTIONS.
<br />3. UNLESS INDICATED OTHERWISE, LAY FLOORING WITH SEAMS PARALLEL TO BUILDING
<br />LINES TO PRODUCE MINIMUM NUMBER OF SEAMS.
<br />4. SPECIAL FLASHED COVED BASE REQUIREMENTS:
<br />a. PROVIDE COVE FILLET AT INTERSECTION OF FLOOR AND WALL TO EASE TRANSITION.
<br />b. MITER CUT, FIT, AND HEAT WELD ALL SEAMS, JOINTS, PENETRATIONS, AND TRANSITIONS.
<br />EXTEND FLOORING TO ELEVATION ABOVE FINISHED FLOOR LEVEL AS INDICATED.
<br />c. CUT TOP EXPOSED EDGE STRAIGHT AND LEVEL.
<br />d. CAP TOP EDGE WITH CAP TRIM. MITER ALL TRIM CORNER JOINTS. INSTALL TRIM IN
<br />MAXIMUM PRACTICAL LENGTHS WITH NO PIECE SHORTER THAN 18 INCHES FOR
<br />CONTINUOUS RUNS LONGER THAN 18 INCHES.
<br />F. RUBBER BASE INSTALLATION:
<br />1. ADHESIVELY INSTALL RESILIENT BASE TIGHTLY TO WALL AND FLOOR SURFACES IN
<br />ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS.
<br />2. FIT JOINTS TIGHT, VERTICAL, AND IN ACCURATE ALIGNMENT. INSTALL BASE IN MAXIMUM
<br />LENGTHS, WITH MINIMUM NUMBER OF JOINTS IN EACH RUN, NO SECTION MAY BE
<br />SHORTER THAN 48 INCHES, EXCEPT AS REQUIRED BY WALL CONDITIONS.
<br />3. INSTALL BASE TO WALLS, COLUMNS, AND CASEWORK TOE KICKS IN ALL AREAS WHERE
<br />RESILIENT BASE IS SCHEDULED.
<br />4. MITER OR COPE INSIDE CORNERS FOR ACCURATE FIT. SCRIBE AND FIT TO DOOR
<br />FRAMES AND OTHER OBSTRUCTIONS.
<br />5. OUTSIDE CORNERS:
<br />a. SCORE BACK OF BASE MATERIAL WITH GROOVING TOOL AND ACCURATELY ALIGN TO
<br />CORNER.
<br />b. FIRMLY ADHERE TO WALL AT BOTH SIDES OF CORNER, WITH NO VISIBLE GAPS AT TOP OF
<br />BASE.
<br />c. STRETCH TOE OF COVED BASE FOR SMOOTH TRANSITION AROUND CORNER, WITH TOE IN
<br />UNIFORM CONTACT WITH THE FINISH FLOORING.
<br />6. REMOVE EXCESS ADHESIVE FROM SURFACES WITHOUT DAMAGE.
<br />G. CLEANING
<br />1. REMOVE EXCESS ADHESIVE FROM FLOOR, BASE, AND WALL SURFACES WITHOUT
<br />DAMAGE.
<br />2. CLEAN BASE AND FLOOR IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
<br />096813 CARPETING
<br />A. QUALITY ASSURANCE: CARPET INSTALLER SHALL HAVE MINIMUM OF 3 YEARS EXPERIENCE
<br />IN CARPET INSTALLATIONS OF SIMILAR SIZE AND SCOPE.
<br />B. WARRANTY: FURNISH MANUFACTURER'S STANDARD 5-YEAR WARRANTY AGAINST WEAR
<br />AND DETERIORATION.
<br />C. MATERIALS:
<br />1. CARPET: AS SCHEDULED ON THE DRAWINGS.
<br />2. PAD: AS SCHEDULED ON THE DRAWINGS.
<br />3. WALK -OFF MAT: AS SCHEDULED ON THE DRAWINGS.
<br />4. ACCESSORIES:
<br />a. CARPET GRIPPERS: ROBERTS ARCHITECTURAL "22-333", OR APPROVED.
<br />b. PAD TAPE: NON -PAPER TAPE RECOMMENDED BY PAD MANUFACTURER.
<br />c. EDGE STRIPS: REDUCER STRIPS; SIZE AND CONFIGURATION AS APPROPRIATE FOR
<br />CONDITIONS; COLOR AS SELECTED BY ARCHITECT FROM MANUFACTURER'S STANDARD
<br />LINE.
<br />d. WALK -OFF MAT SCREED: SCHLUTER; ALUMINUM; PROFILE AS INDICATED ON THE
<br />DRAWINGS, AND TO SUIT JOB CONDITIONS.
<br />} -:00INt�,
<br />e. ADHESIVES: TYPE AS RECOMMENDED BY CARPET, MAT OR SCREED MANUFACTURER FOR
<br />INTENDED USE. USE WATERPROOF ADHESIVE AT WALK -OFF MAT.
<br />f. LATEX UNDERLAYMENT: WHITE PREMIX LATEX FILLER.
<br />g. BACKING: AS INDICATED ON THE DRAWINGS.
<br />D. PREPARATION:
<br />1. CLEAN FLOORS OF DUST, DIRT, SOLVENTS, OIL, GREASE, PAINT, PLASTER, AND OTHER
<br />SUBSTANCES WHICH WOULD BE DETRIMENTAL TO THE PROPER PERFORMANCE OF
<br />ADHESIVE AND CARPET.
<br />2. FILL LOW SPOTS AND CRACKS OVER 1/8 INCH IN WIDTH WITH LATEX UNDERLAYMENT.
<br />E. INSTALLATION:
<br />1. INSTALL CARPETS IN STRICT ACCORDANCE WITH THE MANUFACTURER'S
<br />RECOMMENDATIONS.
<br />2. VERIFY MATCHING OF CARPET PRIOR TO CUTTING AND ENSURE THAT THERE IS NO
<br />VISIBLE VARIATION BETWEEN DYE LOTS.
<br />3. CUT CARPET, WHERE REQUIRED IN A MANNER TO ALLOW PROPER SEAM AND PATTERN
<br />MATCH. ENSURE CUTS ARE STRAIGHT AND TRUE AND UNFRAYED.
<br />4. MAKE SEAMS STRAIGHT AND UNIFORM.
<br />5. SEAMING SHALL BE BY HAND SEWING OR WITH HOT MELT TAPE METHODS.
<br />6. DO NOT CHANGE RUN OF PILE IN ANY ONE ROOM.
<br />7. ENSURE MONOLITHIC COLOR, PATTERN AND TEXTURE MATCH WITHIN EACH DISTINCT
<br />ROOM.
<br />8. INSTALL EDGING STRIPS WHERE CARPET TERMINATES AT OTHER FLOOR COVERINGS.
<br />USE FULL LENGTH PIECES ONLY. BUTT TIGHT TO VERTICAL SURFACES. WHERE
<br />SPLICING CANNOT BE AVOIDED, BUTT ENDS TIGHT, FLUSH, AND ACCURATELY ALIGNED.
<br />F. REMNANTS: UPON COMPLETION OF THE INSTALLATION, CONTACT THE ARCHITECT FOR
<br />SELECTION OF CARPET REMAINING AFTER TRIMMING. CAREFULLY WRAP AND MARK
<br />SEPARATELY THE SELECTED REMNANTS. REMOVE AND DISPOSE OF REMAINDER AT A
<br />LEGAL OFF -SITE LOCATION.
<br />G.CLEANUP:
<br />1. THE PREMISES SHALL BE KEPT FREE FROM UNNECESSARY ACCUMULATION OF TOOLS,
<br />EQUIPMENT AND SURPLUS MATERIALS DURING THE PROGRESS OF THE WORK.
<br />2. REMOVE THREADS WITH SHARP SCISSORS. REMOVE SPOTS WITH MANUFACTURER'S
<br />RECOMMENDED SPOT REMOVER.
<br />3. THOROUGHLY POWER VACUUM ENTIRE SURFACE USING EQUIPMENT WITH MOTOR
<br />DRIVEN BRUSHES.
<br />097733 REINFORCED PLASTIC PANEL WALL COVERINGS
<br />A.SUMMARY: FIBERGLASS REINFORCED POLYESTER PANEL (FRP) WALL COVERING.
<br />B. SUBMITTALS: PRODUCT DATA, INCLUDING ADHESIVES AND SEALANTS.
<br />C.PANEL SYSTEM COMPONENTS:
<br />1. PANEL MATERIAL:
<br />a. MARLITE (AS NOTED IN DRAWINGS).
<br />b. PANEL TYPE: AS SCHEDULED IN THE FINISH LEGEND.
<br />c. THICKNESS: 3/32 INCH.
<br />d. SIZE: 48 INCHES X LENGTH REQUIRED FOR CONDITIONS INDICATED.
<br />e. FIRE RATING: MAXIMUM 25/450 FLAME SPREAD / SMOKE DEVELOPED IN ACCORDANCE
<br />WITH ASTM E84.
<br />2. MOLDINGS: MANUFACTURER'S STANDARD PVC CAP, CORNER, AND DIVISION MOLDINGS;
<br />COLOR TO MATCH PANELS. OMIT BOTTOM TRIM WHERE PANEL ABUTS FLASH COVED
<br />BASE.
<br />3. PANEL AND MOLDING INSTALLATION ADHESIVE: AS RECOMMENDED BY THE FRP PANEL
<br />MANUFACTURER.
<br />4. SEALANT: FLEXIBLE WATERPROOF SILICONE SEALANT FOR BEDDING PANEL EDGES;
<br />WHITE COLOR.
<br />D. INSTALLATION
<br />1. CUTTING AND FITTING
<br />a. CUT PANELS ACCURATELY TO SIZE WITH PROPER ALLOWANCE FOR EXPANSION AND
<br />MOLDINGS.
<br />b. SAND OR FILE ALL EDGES SMOOTH WITHOUT CHIPPING.
<br />c. CUT OPENINGS FOR PENETRATIONS IN ACCURATE LOCATION WITH APPROXIMATE
<br />1/8-INCH CLEARANCE AROUND PENETRATIONS.
<br />2. ESTABLISH CENTERLINE OF EACH DISTINCT FLAT AREA TO BE COVERED. TRIM DIVISION
<br />MOLDINGS TO MATE WITH BASE MOLDINGS; INSTALL IN SOLID BED OF ADHESIVE,
<br />EITHER ON CENTERLINE, OR OFFSET 24 INCHES FROM CENTER, AS NECESSARY TO
<br />MAXIMIZE PANEL WIDTHS AT CORNERS. MOLDING SHALL BE INSTALLED STRAIGHT AND
<br />PLUMB.
<br />3. CUT TOP CAP AND DIVISION OR CORNER MOLDINGS TO SHAPE, WITH EDGES TRIMMED
<br />TO FIT TO ADJACENT MOLDINGS.
<br />4. APPLY SEALANT INTO INSTALLED MOLDINGS IN SEQUENCE WITH PANEL INSTALLATION.
<br />5. APPLY ADHESIVE TO BACKS OF PANELS IN ACCORDANCE WITH THE MANUFACTURER'S
<br />RECOMMENDATIONS.
<br />6. MAINTAIN LINES AND LEVELS OF PANEL EDGES AND MOLDINGS.
<br />7. INSTALL PANELS TIGHT TO FLASH -COVED BASE TRIM.
<br />8. ALLOW 1/8-INCH GAP BETWEEN TOP CAP, CORNER, OR DIVISION MOLDING POSTS, AND
<br />PANEL EDGE; ALL EDGES SHALL BE FIRMLY BEDDED TO THE MOLDINGS IN SEALANT.
<br />9. PROMPTLY REMOVE SEALANT SQUEEZE OUT WITH A DAMP CLOTH, AS WORK
<br />PROGRESSES; REMOVE ADHESIVE WITH APPROPRIATE SOLVENT.
<br />10. INSTALL SEALANT BEHIND FLANGES AND AT PENETRATIONS THROUGH PANELING, AND
<br />BETWEEN TOP CAP OF PANEL AND SUBSTRATE.
<br />11. CLEANING: REMOVE EXCESS ADHESIVE FROM FACE OF LAMINATE USING SOLVENT
<br />RECOMMENDED B MANUFACTURER,
<br />098100 ACOUSTIC INSULATION
<br />A.SUMMARY: ACOUSTIC INSULATION AND SEALANTS.
<br />B. MATERIALS:
<br />1. MANUFACTURERS: JOHNS MANVILLE "SOUND CONTROL
<br />BATTS", CERTAINTEED "GREENGUARD CERTIFIED", OWNS CORNING "SOUND CONTROL
<br />BATTS."
<br />2. ACOUSTIC INSULATION: ASTM C665, TYPE I; UNFACED GLASS FIBER BATTS, BLANKETS,
<br />OR ROLLS; MINIMUM FIRE HAZARD CLASSIFICATION RATING OF 25/50 PER ASTM E84;
<br />MINIMUM 3-INCH THICK, UNLESS REQUIRED OTHERWISE TO MEET THE STC
<br />REQUIREMENTS INDICATED OR SPECIFIED; WIDTHS TO FRICTION -FIT BETWEEN STUDS,
<br />WHERE INDICATED FOR INSTALLATION IN STUD WALLS.
<br />3. ACOUSTICAL SEALANT: NON -HARDENING, NON -SKINNING, FOR USE IN CONJUNCTION
<br />WITH GYPSUM BOARD; SIMILAR TO USG "ACOUSTICAL SEALANT."
<br />4. ACCESSORIES: FURNISH OTHER ACCESSORIES SUCH AS FASTENERS AND RETAINERS,
<br />NOT SPECIFICALLY DESCRIBED, BUT REQUIRED FOR A COMPLETE INSTALLATION.
<br />C.INSULATION:
<br />1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS, AND AS INDICATED.
<br />2. TRIM INSULATION NEATLY TO FIT SPACES..INSTALL WITHOUT GAPS OR VOIDS.
<br />D. SEAL PENETRATIONS THROUGH ACOUSTICAL ASSEMBLIES, EXCEPT FOR
<br />PENETRATIONS IN FIRE RATED CONSTRUCTION TO RECEIVE FIRESTOPPING.
<br />099000 PAINTING AND COATING
<br />A.SUMMARY: SITE APPLIED PAINT COATINGS, EXCEPT AS OTHERWISE NOTED.
<br />B. QUALITY ASSURANCE:
<br />1. APPLICATOR: COMPANY SPECIALIZING IN COMMERCIAL PAINTING AND FINISHING WITH
<br />A MINIMUM OF THREE YEARS DOCUMENTED EXPERIENCE.
<br />2. VISUAL STANDARDS: EACH DISTINCT AREA OF THE FINISHED WORK SHALL BE FREE OF
<br />VARIATIONS IN COLOR AND SHEEN, ORANGE PEEL, RUNS, SAGS, BLISTERING,
<br />CHECKING, CRACKING, SCRATCHES, DUST, DIRT, BUGS, AND OTHER CONTAMINANTS.
<br />C.SITE CONDITIONS:
<br />1. WEATHER CONDITIONS:
<br />a. DO NO EXTERIOR WORK ON UNPROTECTED SURFACES WHEN RAINING, OR OTHER
<br />MOISTURE IS PRESENT OR EXPECTED, OR BEFORE APPLIED PAINTS CAN DRY OR ATTAIN
<br />PROPER CURE.
<br />b. ALLOW WETTED SURFACES TO DRY AND ATTAIN TEMPERATURES AND CONDITION
<br />SPECIFIED HEREINAFTER BEFORE PROCEEDING WITH PREVIOUSLY STARTED WORK.
<br />2. TEMPERATURE:
<br />a. DO NO PAINTING WORK WHEN SURFACE AND AIR TEMPERATURES ARE BELOW 40
<br />DEGREES F OR BELOW THOSE TEMPERATURES RECOMMENDED BY THE MANUFACTURER
<br />FOR THE MATERIAL TYPE USED.
<br />b. MINIMUM TEMPERATURES FOR LATEX FINISHES: 45 DEGREES F FOR INTERIOR WORK AND
<br />50 DEGREES F. FOR EXTERIOR WORK, UNLESS APPROVED OTHERWISE.
<br />3. LIGHTING: MAINTAIN A LIGHTING LEVEL OF MINIMUM 50 FOOT-CANDLES ON THE
<br />SURFACES TO BE PAINTED OR FINISHED.
<br />4. VENTILATION: PROVIDE ADEQUATE CONTINUOUS VENTILATION.
<br />D. MAINTENANCE:
<br />1. FURNISH OVERAGE OF PAINT MATERIALS EQUAL TO 10 PERCENT MINIMUM OF
<br />QUANTITY OF EACH PAINT AND TRANSPARENT FINISH SYSTEM COMPONENT, COLOR
<br />AND SHEEN REQUIRED FOR THE WORK, BUT FURNISH NOT MORE THAN FIVE FULL ONE
<br />GALLON CANS, NOR LESS THAN TWO FULL ONE QUART CANS, OF EACH TYPE.
<br />OVERRUNS IN EXCESS OF FIVE GALLONS MAY BE FURNISHED TO T-MOBILE AT THE
<br />CONTRACTOR'S OPTION. OVERAGE SHALL BE TAKEN FROM THE BATCH MIX FURNISHED
<br />FOR THE WORK. OVERAGE SHALL BE FURNISHED IN COMPLETELY FILLED, PROPERLY
<br />LABELED, SEALED CANS.
<br />T Mobile
<br />12920 SE 38th STREET
<br />BELLEVUE, WA 98006
<br />www.T-Mobile.com
<br />COPYRIGHT NOTICE
<br />THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO
<br />COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF
<br />THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED JANUARY 2003, THE PROTECTION
<br />INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND
<br />COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH
<br />PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS
<br />MAY RESULT IN CESSATION OF CONSTRUCTION, BUILDING SEIZURE, AND/OR
<br />MONETARY LIABILITY.
<br />ARCHITECT:
<br />rmUzioN
<br />9096 EAST BAHIA DRIVE
<br />SUITE 103
<br />SCOTTSDALE, AZ 85260
<br />DESIGN@FUZIONVE.COM
<br />VVVVVV.FUZIONVE.COM
<br />VENDOR PROJECT NO: 21.11.212680
<br />oo LOUas �,, ✓ ..v
<br />OS-1
<br />(1100 4
<br />Sr�REo
<br />02/10/2022
<br />CONSULTING ENGINEER:
<br />N
<br />W
<br />Lu
<br />wv
<br />Q r
<br />Lo
<br />W > M
<br />C� J J
<br />J = �
<br />V J
<br />m
<br />J. J
<br />LJ.IJ=
<br />0
<br />CO
<br />o.qa
<br />JC-4 W
<br />m ti N
<br />J
<br />J
<br />,Q
<br />V
<br />DATE: February 5, 2022
<br />SCALE: AS NOTED
<br />DRAWN BY: LEO V.
<br />SAP NUMBER:
<br />4SIR
<br />CORPORATE TENANT REBUILD
<br />LDC
<br />SHEET TITLE:
<br />SPECIFICATIONS
<br />SHEET NUMBER:
<br />4
<br />3
<br />M
<br />1
<br />A705