Laserfiche WebLink
I I I ii I I 1 U 1 I <br />4 <br />3 <br />2 <br />1 <br />UI <br />Ill <br /><I <br />DIYISI N 9 FINISHES C � . O E �T <br />E. MATERIALS: <br />1. GENERAL REQUIREMENTS: PAINTS NOT SPECIFICALLY LISTED SHALL BE "FIRST <br />QUALITY" COMMERCIAL PRODUCTS FROM ONE OF THE FOLLOWING: <br />a. BENJAMIN MOORE PAINT COMPANY. <br />b. ICI PAINTS NORTH AMERICA <br />2. ACRYLIC WALL SIZE: ONE OF THE FOLLOWING: <br />a. ICI DEVOE "WONDERPRIME" DR51701 VAPOR BARRIER PRIMER/SEALER. <br />b. ICI DULUX "ULTRA -HIDE" 1060 VAPOR BARRIER PRIMER/SEALER. <br />c. BENJAMIN MOORE PAINT COMPANY "MOORE'S WALL -GRIP 203." <br />F. SURFACE PREPARATION: <br />1. PREPARE SURFACES BY REMOVING ALL DIRT, DUST, GREASE, OIL, MOISTURE, AND <br />OTHER CONTAMINANTS WHICH WILL IMPAIR THE PROPER ADHESION OF THE FINISH. <br />2. FERROUS METAL SHOP PRIMED UNDER OTHER SECTIONS: CLEAN PREVIOUSLY PRIMED <br />SURFACES WITH NON -PETROLEUM BASED SOLVENT TO REMOVE OIL AND GREASE. <br />REMOVE LOOSE RUST, BLISTERED AND PEELING PAINT TO BARE METAL BY SCRAPING, <br />SANDING, AND WIRE BRUSHING IN ACCORDANCE WITH SSPC-SP2 AND SSPC-SP3. <br />IMMEDIATELY APPLY TOUCH UP PRIME DAMAGED OR ABRADED SURFACES. LIGHTLY <br />SAND ALL SHOP PRIME PAINTED SURFACES TO RECEIVE PAINT FINISH. <br />3. GALVANIZED FERROUS METAL: CLEAN WITH NON -PETROLEUM BASED IN ACCORDANCE <br />WITH SSPC-SP1; ABRADE SURFACE WITH 3M "SCOTCHBRITE HEAVY DUTY" (BROWN) <br />PAD, AS NECESSARY TO ACHIEVE SUFFICIENT PROFILE FOR PAINT ADHESION. <br />4. UNPRIMED FERROUS METAL: <br />a. SOLVENT CLEAN IN ACCORDANCE WITH SSPC SP-1. <br />b. COMMERCIAL BLAST PER SSPC SP6. <br />5. WOOD - OPAQUE PAINT FINISH: <br />a. SPOT COAT KNOTS, PITCH STREAKS, AND SAPPY SECTIONS WITH SEALER. <br />b. FILL ALL NAIL HOLES AND CRACKS. SAND FILLER SMOOTH AND LEVEL WITH WOOD <br />SURFACE. <br />6. WOOD - TRANSPARENT FINISH: FILL ALL EXPOSED FINISH NAIL HOLES AND CRACKS <br />WITH MATCHING COLOR FILLER AFTER PRIME COAT IS APPLIED. SAND FILLER SMOOTH <br />AND LEVEL WITH ADJACENT SURFACES. <br />7. CONCRETE AND CONCRETE MASONRY UNITS: REMOVE ALL CONTAMINANTS BY <br />WASHING AND WIRE BRUSHING. SANDBLAST IF NECESSARY. <br />8. GYPSUM PLASTER AND WALL BOARD: REMOVE ALL LIGHT DUST AND DIRT. <br />9. EXISTING FINISHED SURFACES TO BE REPAINTED: <br />a. REMOVE LOOSE, BLISTERED, SCALED, OR CRAZED FINISHES TO BARE SUBSTRATE; <br />FEATHER NEW WORK INTO EXISTING WORK. PREPARE SURFACES TO THE NEAREST <br />BREAK LINE IF NECESSARY TO BLEND NEW FINISHES WITH OLD FINISHES. <br />b. WASH AND RINSE SURFACES WITH TRISODIUM PHOSPHATE AND WATER OR OTHER <br />SOLUTION REQUIRED TO REMOVE REMAINING FILM WAX OIL GREASE, SMOKE OR <br />FOREIGN MATTER WHICH WILL IMPAIR BOND OR CAUSE BLEED THROUGH OF NEWLY <br />APPLIED FINISHES. <br />c. LIGHTLY SAND, OR APPLY A LIQUID DEGLOSSER ON EXISTING SEMI -GLOSS AND <br />HIGH -GLOSS FINISHES BEFORE REFINISHING. <br />G. SPECIAL APPLICATION REQUIREMENTS: <br />1. UNLESS SPECIFIED OR INDICATED OTHERWISE, FOLLOW PAINT MANUFACTURER'S <br />LABEL DIRECTIONS FOR GENERAL APPLICATION PROCEDURES AND COVERAGE RATES. <br />2. DO NOT APPLY FINISHES ON SURFACES THAT ARE NOT SUFFICIENTLY DRY. MAKE SURE <br />EACH COAT OF FINISH IS DRY AND HARD BEFORE A FOLLOWING COAT IS APPLIED <br />UNLESS THE MANUFACTURER'S DIRECTIONS STATE OTHERWISE. <br />3. TINT FILLER TO MATCH STAIN WHEN CLEAR FINISHES ARE SPECIFIED; WORK FILLER <br />WELL INTO GRAIN AND, BEFORE IT HAS SET, WORKING PERPENDICULARLY TO THE <br />GRAIN, WIPE THE EXCESS FROM THE SURFACE. <br />4. OPAQUE FINISHES: <br />a. APPLY NUMBER OF COATS SCHEDULED FOR EACH APPLICATION, EXCEPT THAT <br />ADDITIONAL FINISH COATS SHALL BE APPLIED AS NECESSARY FOR COMPLETE HIDING OF <br />SUBSTRATE COLORS. <br />b. APPLY PRIMER COATS UN -TINTED. WHERE MORE THAN ONE COAT OF PAINT IS REQUIRED, <br />TINT EACH SUCCEEDING COAT UP TO THE FINAL COAT SIMILAR IN TINT, BUT SLIGHTLY <br />LIGHTER IN VALUE (SHADE). <br />c. SAND LIGHTLY BETWEEN COATS IF NECESSARY TO ACHIEVE REQUIRED FINISH; SAND <br />BETWEEN ALL COATS APPLIED TO WOOD SUBSTRATES. <br />5. ROLLERS FOR APPLICATION AND BACKROLLING OF LATEX PAINTS SHALL HAVE A NAP <br />OF 3/8 INCH OR LESS. <br />6. WHERE ROLLER TEXTURE IS SCHEDULED FOR APPLICATION TO GYPSUM BOARD <br />SURFACES, FINISH COATS MAY BE ROLLER APPLIED, OR SPRAY APPLIED AND <br />BACKROLLED AT CONTRACTOR'S OPTION. <br />7. FACTORY PRIMED SURFACES: APPLY SCHEDULED FINISH SYSTEM, LESS PRIMER COAT, <br />EXCEPT AS NECESSARY TO FOR PATCHING DAMAGE TO FACTORY PRIME COATING. <br />8. EXCEPT WHERE SCHEDULED OR INDICATED OTHERWISE, THE INTENT IS TO PAINT ALL <br />NEW ROOMS AND AREAS. <br />9. EXISTING AREAS WHICH HAVE NOT BEEN REMODELED OR DO NOT HAVE PATCHED <br />SURFACES ARE NOT TO BE REPAINTED. WHERE EXISTING SURFACES HAVE BEEN <br />REMODELED OR PATCHED THE ENTIRE ROOM IS TO BE REPAINTED, INCLUDING THE <br />ASSOCIATED ACCESS PANELS, ELECTRICAL PANELS, HOLLOW METAL DOORS AND <br />FRAMES (BOTH SIDES), AND SIMILAR ELEMENTS WITHIN THE ROOM. <br />H. INTERIOR SYSTEMS: <br />1. GYPSUM BOARD - LATEX SYSTEM: <br />a. SYSTEM: THREE COATS - FIRST COAT LATEX PRIMER SEALER (UN -TINTED), SECOND AND <br />THIRD COAT LATEX PAINT. <br />b. SHEEN: ROLLER TEXTURE, SATIN SHEEN, EXCEPT PROVIDE FLAT SHEEN AT LIGHT COVES, <br />CEILINGS, SKYLIGHT AREAS, CLERESTORY AREAS, INTERIOR FASCIAS, AND OTHER LIGHT <br />SENSITIVE SURFACES. VERIFY LOCATIONS OF EACH SHEEN WITH ARCHITECT BEFORE <br />PROCEEDING WITH WORK. <br />c. APPLICATION: <br />i. USE ON ALL EXPOSED GYPSUM BOARD SURFACES, INCLUDING THE EXPOSED PORTIONS <br />OF WALL SURFACES BETWEEN ADJACENT WALL -MOUNTED FIXTURES. <br />ii, PROVIDE PRIME COAT ONLY BEHIND PERMANENTLY MOUNTED MECHANICALLY WALL <br />MOUNTED FIXTURES. <br />iii. DO NOT APPLY PRIMER OR PAINT COATINGS TO SURFACES TO RECEIVE ADHESIVELY <br />MOUNTED MIRRORS OR TILE. <br />2. GYPSUM BOARD - SURFACES TO RECEIVE WALL COVERING: APPLY ONE COAT OF <br />ACRYLIC WALL SIZE. <br />I. COLOR SCHEDULE: PROVIDE PAINT COLORS TO MATCH THOSE INDICATED ON THE <br />DRAWINGS. WHERE A PAINT COLOR IS LISTED FROM A SPECIFIC MANUFACTURER, PAINT <br />PRODUCTS FROM OTHER APPROVED MANUFACTURERS MAY BE USED, PROVIDED THE <br />COLOR EXACTLY MATCHES THE SPECIFIED COLOR, AND THE PAINT SYSTEM MEETS THE <br />SPECIFIED REQUIREMENTS. WHERE NO PAINT COLOR IS INDICATED, PROVIDE COLOR AND <br />SHEEN AS SELECTED BY THE ARCHITECT. <br />1. INSTALL SEALANT BEHIND FLANGES AND AT PENETRATIONS THROUGH PANELING, AND <br />BETWEEN TOP CAP OF PANEL AND SUBSTRATE. <br />2. CLEANING: REMOVE EXCESS ADHESIVE FROM FACE OF LAMINATE USING SOLVENT <br />RECOMMENDED BY MANUFACTURER. <br />Df�'imb 1 q SP ci TtfES <br />101402 REST ROOM SIGNAGE <br />A. SUMMARY: <br />1. CODE -REQUIRED INTERIOR SIGNAGE. <br />2. INSTALLATION OF SIGNAGE. <br />B. SYSTEM DESCRIPTION: <br />1. ACCESSIBILITY SIGNAGE: PROVIDE ACRYLIC PLASTIC REVERSE SILK SCREENED SIGNS <br />WITH INTERNATIONAL SYMBOL OF ACCESSIBILITY, RAISED LETTERS, AND BRAILLE, AT <br />ACCESSIBLE TOILET FACILITIES; ONE FOR EACH SEX. <br />C. QUALITY ASSURANCE: <br />1. REGULATORY REQUIREMENTS: SIGNAGE SHALL CONFORM TO THE REQUIREMENTS OF <br />THE JURISDICTIONAL CODE AUTHORITIES. <br />D. MATERIALS: <br />1. PLASTIC SHEET: 1/8 INCH THICK ACRYLIC SHEET; LOW GLOSS FINISH. <br />2. DOUBLE STICK TAPE: 3M "SCOTCH BRAND #665" DOUBLE -STICK, DOUBLE -COATED TAPE, <br />1/4" WIDE. <br />SECTION 10810 -TOILET ACCESSORIES <br />A. QUALITY ASSURANCE <br />1. CONFORM TO APPLICABLE ACCESSIBILITY CODE FOR LOCATING ACCESSORIES. <br />B. MATERIALS <br />1. STAINLESS STEEL: SHEET - IN ACCORDANCE WITH ASTM A 167, TYPE 304. <br />2. STAINLESS STEEL: TUBING - IN ACCORDANCE WITH ASTM A 269. <br />3. GALVANIZED STEEL: IN ACCORDANCE WITH ASTM A 366. <br />4. MIRROR GLASS: IN ACCORDANCE WITH ASTM C 1036, TYPE L, CLASS 1, QUALITY Q1. <br />DIVISION 10SPECIALTIES, tONT. <br />C. ACCESSORIES <br />1. FASTENERS: STAINLESS STEEL WHERE EXPOSED, HOT DIP GALVANIZED WHERE <br />CONCEALED; TYPE BEST SUITED TO SUBSTRATE CONDITIONS. <br />2. FRAMED MIRROR: BOBRICK B-1652436 <br />3. WASTE RECEPTACLE: PROVIDED BY T-MOBILE, INSTALLED BY G.C.. <br />4. SEAT COVER DISPENSER: HEALTH GUARDS ITEM# 420660, MODEL #HG12-FURNISHED BY <br />T-MOBILES VENDOR, INSTALLED BY G.C. <br />5. GRAB BAR: BOBRICK B-6806 <br />6. AUTOMATIC HAND DRYER: EXCEL XL-BW WITH ADA RECSEED MOUNTING KIT 40502. <br />FIXED NOZZLE, WHITE FINISH. FURNISHED BY T-MOBILE'S VENDOR, INSTALLED BY G.C. <br />7. 7. TOILET PAPER DISPENSER: BOBRICK B-76857 <br />D. FABRICATION <br />1. USE STAINLESS STEEL FOR EXPOSED SURFACES; GALVANIZED STEEL MAY BE USED IN <br />CONCEALED LOCATIONS. FORM EXPOSED SURFACES FROM SINGLE SHEET OF STOCK, <br />FREE FROM JOINTS, AND FLAT WITHOUT DISTORTION. WELD JOINTS OF FABRICATED <br />COMPONENTS AND GRIND SMOOTH. FABRICATE GRAB BARS OF TUBING, FREE OF <br />VISIBLE JOINTS, RETURN TO WALL WITH END ATTACHMENT FLANGES. KNURL GRIP <br />SURFACES. FABRICATE SOAP DISPENSERS TO OPERATE WITH LESS THAN 5 POUND <br />FORCE. PROVIDE HANGERS, ADAPTERS, ANCHOR PLATES AND ACCESSORIES <br />REQUIRED FOR INSTALLATION. KEY LOCKS ALIKE; FURNISH SIX (6) KEYS. <br />2. FRAMED MIRRORS: ONE COAT OF ORGANIC MIRROR BACKING COMPOUND TO THE BACK <br />SURFACE OF THE GLASS. <br />3. BACKING: GALVANIZED SHEET STEEL. ISOLATE GLASS FROM FRAME AND BACKING WITH <br />RESILIENT, WATERPROOF PADDING <br />4. FINISHES: <br />a. STAINLESS STEEL: NO.4 SATIN. <br />b. GALVANIZING: ASTM A 123 TO 1.25 OUNCES PER SQUARE FOOT. <br />c. CHROME PLATING: ASTM B 456, TYPE SC 2, POLISHED FINISH <br />5. SHOP ASSEMBLE UNITS AND PACKAGE COMPLETE WITH ANCHORS AND FITTINGS. <br />E. INSTALLATION <br />1. SET PLUMB AND LEVEL, SQUARE AND RIGIDLY ANCHORED. INSTALL IN ACCORDANCE <br />WITH MANUFACTURER'S INSTRUCTIONS. <br />104416 FIRE EXTINGUISHERS AND CABINETS <br />A. SUBMITTALS: PRODUCT LITERATURE, INCLUDING EXTINGUISHER DIMENSIONS. <br />B. EXTINGUISHERS: MULTI -PURPOSE DRY CHEMICAL TYPE: HEAVY DUTY DOT STEEL TANK; UL <br />RATING 2A-10B;C, 5 LB CAPACITY, FM APPROVED; RED ENAMEL FINISH; PRESSURE GAGE; <br />METAL VALVES AND SIPHON TUBES. <br />C. FIRE EXTINGUISHER CABINETS: <br />1. TYPE ONE OF THE EMER POTTER-R: FOLLOWING): INC.-DV-VB-RR OR <br />O 0 INC #7023 <br />#7023-DV-VB-RR-FRC AT RATED CONSTRUCTION, LARSEN'S MANUFACTURING COMPANY <br />#2409-R3 OR #FS-2409-R3 AT RATED CONSTRUCTION, J.L INDUSTRIES #1817V17 OR <br />#1817V17 FIRE-FX AT RATED CONSTRUCTION. <br />2. STYLE: SEMI -RECESSED (APPROXIMATELY 2-1/2" PROJECTION; ROLLED EDGE); STEEL <br />FRAME AND DOOR WITH CONTEMPORARY 2 INCH WIDE DOUBLE STRENGTH GLASS <br />INSERT. <br />3. FINISH: MANUFACTURER'S STANDARD BAKED WHITE ENAMEL INTERIOR; FURNISH TO <br />SECTION 099000 FOR FIELD PAINTING. <br />4. LETTERING: BLACK LETTERING IN VERTICAL FORMAT. <br />D. FIRE EXTINGUISHER BRACKETS: MANUFACTURER'S STANDARD J-TYPE. PROVIDE AT FIRE <br />EXTINGUISHER LOCATIONS WHERE NO CABINET IS INDICATED. <br />E. INSTALLATION: <br />1. INSTALL BRACKETS 48 INCHES FROM FINISHED FLOOR TO TOP OF BRACKET. <br />2. SECURE RIGIDLY IN PLACE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. <br />3. INSTALL CABINETS PLUMB AND LEVEL IN WALL OPENINGS IN LOCATIONS AS INDICATED. <br />UNLESS OTHERWISE INDICATED, INSTALL 30 INCHES FROM FINISHED FLOOR TO INSIDE <br />BOTTOM OF CABINET. <br />4. WHEN RECESSED CABINETS ARE INSTALLED IN FIRE RATED WALLS, MAINTAIN FIRE <br />RESISTANCE RATING CONTINUOUSLY BEHIND THE CABINET. <br />5. INSTALL IN LOCATIONS AS INDICATED ON THE DRAWINGS. <br />105623 WIRE STORAGE SHELVING <br />A. GENERAL: SHELVING SHALL CARRY THE APPROVAL OF THE NATIONAL SANITATION <br />FOUNDATION (NSF) <br />B. PRODUCT: APPROVED PRODUCTS BELOW (OR EQUAL): <br />a. ALERA WIRE SHELVING 48" X 24" X 72" <br />b. METRO SUPER ERECTA® (SES) 48" X 24" X 72" <br />C. MATERIAL: SHELVES SHALL BE BRIGHT BASIC CARBON STEEL WIRE. POSTS SHALL BE COLD <br />ROLLED CARBON STEEL TUBING, ELECTRIC WELDED. PLASTIC CLIPS MATERIAL SHALL BE <br />ABS. <br />D. FINISH: BRIGHT PLATED <br />E. SHELVES: CONSTRUCTION SHALL BE OF OPEN WIRE DESIGN OFFERING GREATER LIGHT <br />PENETRATION AND VISIBILITY, LIGHTER WEIGHT, AIR CIRCULATION AND MINIMAL DUST AND <br />DIRT ACCUMULATION. <br />F. FABRICATION: FACE RIBS SHALL RUN FRONT TO BACK EQUALLY SPACED ON 20.6MM <br />CENTERS AND TO BE OF 3AMM WIRE. EACH SIDE (FOUR) OF SHELF SHALL CONSIST OF A <br />CORRUGATED, REINFORCING TRUSS OF 4,5MM WIRE. AT THE FRONT AND BACK OF THE <br />SHELF, THIS CORRUGATED REINFORCING SHALL BE WELDED TO 6.2MM RIB WIRE RUNNING <br />PERPENDICULAR AND ABOVE THE FACE RIBS. A 6.2MM RIB WIRE SHALL BE WELDED TO THE <br />BOTTOM OF THE TRUSS. AT THE ENDS OF THE SHELF, THE CORRUGATED REINFORCING <br />TRUSS SHALL BE WELDED TO PARALLEL 6.2MM WIRE RIBS. DEPENDING UPON THE WIDTH <br />AND LENGTH OF THE SHELF, IT SHALL HAVE THREE OR FIVE LONGITUDINAL RIBS (6.2 MM) <br />WELDED TO THE FACE RIBS. IN ADDITION, CERTAIN LONGER LENGTHS SHALL HAVE ONE OR <br />TWO CORRUGATED REINFORCING TRUSSES (6.2MM) WELDED TO THE UNDERSIDE. AT EACH <br />CORNER OF THE SHELF THERE SHALL BE A TAPERED, CONICAL FITTING MADE OF 2.6MM <br />COLD ROLLED STEEL TO THE PARALLEL RIB SUPPORTS. THE FITTING SHALL BE DESIGNED <br />TO ACCOMMODATE THE VERTICAL SUPPORTS. THE CORRUGATED TRUSS SHALL BE IN THE <br />SHAPE OF THE LETTER "W." <br />G. POSTS: SHALL OF 1" O.D. ROUND STEEL TUBING, 1.5 MM THICK. THEY SHALL HAVE ROLLED <br />GROOVES SPACED AT 1" O.C. ALONG THEIR LENGTH. THE TOPOF THE POST SHALL HAVE A <br />FINISHED PLASTIC CAP. A DIE CAST THREADED INSERT WITH AN ADJUSTABLE LEVELING <br />FOOT SHALL BE SHIPPED LOOSE FOR LATER INSERTION INTO THE POST BOTTOM. <br />H. METHOD OF ASSEMBLY: SHALL BE OF THE FRUSTAL-CONICAL DESIGN INCORPORATING A <br />TWO PART TAPERED PLASTIC CLIP. ENGAGEMENT AND LOCKING SHALL BE ACCOMPLISHED <br />WITH A PROTRUDING BEAD ON THE INNER CIRCUMFERENCE OF THE PLASTIC CLIP WHICH <br />WILL MATCH THE GROOVE IN THE POST. TWO PLASTIC CLIPS SHALL BE ATTACHED TO EACH <br />CORNER POST FOR EACH SHELF. BOTH THE CLIPS AND THE CORNER FITTING OF THE <br />SHELVES SHALL HAVE THE IDENTICAL TAPER TO CREATE A WEDGE EFFECT, THEREBY <br />LOCKING THE SHELF SECURELY IN A RIGID POSITION. NO SCREWS OR OTHER FITTINGS <br />SHALL BE REQUIRED TO EFFECT THIS ASSEMBLY. SHELVES SHALL BE VERTICALLY <br />ADJUSTABLE IN 1" INCREMENTS. <br />I. LOAD CAPACITY: 800 LBS. PER SHELF EVENLY DISTRIBUTED. MAXIMUM LOAD PER <br />ASSEMBLED UNIT NOT TO EXCEED 2,000 LBS. <br />J. CASTORS: SHALL BE ZINC PLATE ROUND STEM CASTER WITH POLYURETHANE TREAD AND <br />WHEEL DIMENSIONS OF 5" X 1 %". WIRE SHELF CARTS ARE STANDARD WITH (2) SWIVEL <br />AND (2) SWIVEL LOCKING CASTORS. <br />K. SEISMIC ANCHORAGE: WHERE REQUIRED BY CODE AND/OR JURISDICTION HAVING <br />GOVERNANCE, PROVIDE CROSS -BRACING AND ANCHOR PLATES FOR SUPER ERECTA® <br />(SES) PER MANUFACTURER'S SPECIFICATIONS, <br />E3NISIt3N 11-NOT USA <br />DI' LS#C f.1,1 Fl f f I H: O <br />0124813 -ENTRANCE FLOOR MATS AND FRAMES <br />A. RELATED DOCUMENTS <br />1. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND <br />SUPPLEMENTARY CONDITIONS AND DIVISION 01 SPECIFICATION SECTIONS, APPLY TO <br />THIS SECTION. <br />B. PRODUCTS <br />1. REGULATORY REQUIREMENTS: COMPLY WITH APPLICABLE PROVISIONS IN [THE U.S. <br />ARCHITECTURAL & TRANSPORTATION BARRIERS COMPLIANCE BOARD'S ADA-ABA <br />ACCESSIBILITY GUIDELINES FOR BUILDINGS AND FACILITIES] AND [ICC A117.1] <br />I-V `I ` N .F Nf HIN - C NT, <br />t� 1S C� �! �f� � ��, a <br />2. RESILIENT ENTRANCE MAT: RETAIN "MANUFACTURERS" PARAGRAPH AND LIST OF <br />MANUFACTURERS BELOW TO REQUIRE PRODUCTS FROM MANUFACTURERS LISTED OR <br />A COMPARABLE PRODUCT FROM OTHER MANUFACTURERS. <br />3. MANUFACTURERS: <br />a. LEGACY NOP BY MATS INC., PO BOX 839,37 SHUMAN AVENUE, STOUGHTON, MA, 02072; <br />TELEPHONE 800-MATS-INC (800-628-7462) OR 781-344-1536; FAX 781-344-1537; <br />WWW.MATSINC.COM. <br />b. FOR VESTIBULES OR WHERE LOWER PROFILE IS REQUIRED: SUPREME NOP BY MATS INC. <br />4. RECESSED FRAMES: AS SHOWN IN DRAWINGS. <br />5. COLOR: MILL FINISH <br />C. EXECUTION <br />1. EXAMINE SUBSTRATES AND CONDITIONS WHERE FLOOR MATS WILL BE INSTALLED. DO <br />NOT PROCEED WITH INSTALLATION UNTIL UNSATISFACTORY CONDITIONS ARE <br />CORRECTED. SUB FLOOR SHALL BE CLEAN AND DRY, AND WITHIN ACCEPTABLE <br />TOLERANCES. <br />2. INSTALLATION <br />a. INSTALL RECESSED MAT FRAMES TO COMPLY WITH MANUFACTURER'S WRITTEN <br />INSTRUCTIONS. SET MAT TOPS AT HEIGHT RECOMMENDED BY MANUFACTURER FOR MOST <br />EFFECTIVE CLEANING ACTION; COORDINATE TOPS OF MAT SURFACES WITH BOTTOMS OF <br />DOORS THAT SWING ACROSS MATS TO PROVIDE CLEARANCE BETWEEN DOOR AND MAT. <br />b. INSTALL NECESSARY SHIMS, SPACERS, AND ANCHORAGES FOR PROPER LOCATION, AND <br />SECURE ATTACHMENT OF FRAMES. <br />3. INSTALL GROUT AND FILL AROUND FRAMES AND, IF REQUIRED TO SET MAT TOPS AT <br />PROPER ELEVATIONS, IN RECESSES UNDER MATS. FINISH GROUT AND FILL SMOOTH <br />AND LEVEL. <br />D. PROTECTION <br />4. AFTER COMPLETING FRAME INSTALLATION AND CONCRETE WORK, PROVIDE <br />TEMPORARY FILLER OF PLYWOOD OR FIBERBOARD IN RECESSES AND COVER FRAMES <br />WITH PLYWOOD PROTECTIVE FLOORING. MAINTAIN PROTECTION UNTIL CONSTRUCTION <br />TRAFFIC HAS ENDED AND PROJECT IS NEAR SUBSTANTIAL COMPLETION. <br />DIVISION`13 -NOT USED <br />DIYISICiN 14 *AN07 USED <br />DIVISION 'IICI, fly f=ffE <br />SECTION 15000 - MECHANICAL, PLUMBING & FIRE PROTECTION <br />A. MECHANICAL <br />1. INSTALLATION AND MATERIALS OF ALL SYSTEMS SHALL CONFORM TO THE <br />REQUIREMENTS OF THE CITY, COUNTY, STATE, AND NATIONAL CODES. <br />2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR AND REQUIRED TO VISIT THE SITE, <br />VERIFY DIMENSIONAL DATA AND REVIEW EXISTING CONDITIONS BEFORE PROCEEDING <br />WITH THE WORK. ANY CONFLICTS WITH THE EXISTING CONDITIONS SHALL BE BROUGHT <br />TO THE ATTENTION OF THE ARCHITECT. <br />3. A COMPLETE AND OPERABLE SYSTEM SHALL BE PROVIDED. THIS IS DEFINED AS ONE <br />WHICH HAS BEEN FURNISHED, MOUNTED, INSTALLED, AND PLACED IN OPERATION, <br />BALANCED FOR AIR AND WATER, TESTED FOR CONFORMANCE TO THE CAPACITIES <br />CORRESPONDING TO THE DESIGN CRITERIA. <br />4. THE SYSTEM SHALL BE INSTALLED AND ADJUSTED IN ACCORDANCE TO THE <br />MANUFACTURER'S RECOMMENDATIONS, TESTED FOR SEQUENCE OF CONTROL <br />INCLUDING FAIL SAFE AND LIFE SAFETY CONSIDERATIONS AND AVAILABLE IN A CLEAN <br />CONDITION. <br />5. COORDINATE LOCATIONS OF ALL VISIBLE DEVICES WITH THE LIGHTING PLAN. <br />B. DESIGN CRITERIA - HVAC SYSTEM <br />1. MAINTAIN AN AVERAGE TEMPERATURE OF 68 TO 70 DEGREES DURING THE WINTER. 75 <br />TO 77 DEGREES DURING THE SUMMER. <br />2. INTERIOR ZONES SHALL BE DESIGNED TO SERVE 1,800 SQUARE FEET EACH. EXTERIOR <br />ZONES SHALL BE DESIGNED TO SERVE 700 SQUARE FEET EACH. <br />3. EXHAUST ALL TOILET ROOMS TO THE OUTSIDE AT A RATE OF 2 CFM PER SQ. FT. <br />C. DESIGN CRITERIA - PLUMBING SYSTEM <br />1. PROVIDE COMPLETE PLUMBING SYSTEMS NECESSARY TO OPERATE THE DEVICES <br />SHOWN IN THESE DOCUMENTS. <br />D. DESIGN CRITERIA - FIRE PROTECTION SYSTEM <br />1. PROVIDE THE NECESSARY FIRE SPRINKLER SYSTEMS AND FIRE ALARM SYSTEMS TO <br />GIVE COMPLETE PROTECTION AS REQUIRED BY CODE. <br />E. MEP / SPRINKLER NOTES <br />1. ALL FIRE SPRINKLER WORK SHALL BE PERFORMED BY A BASE BUILDING APPROVED <br />CONTRACTOR. SPRINKLER HEADS IN GYPSUM BOARD AND MALL FRONTS SHALL BE <br />CONCEALED HEAD TYPE. SEMI -RECESSED OR CONCEALED TYPE MAY BE USED IN <br />LAY -IN CEILINGS VISIBLE TO CUSTOMERS. SURFACE MOUNTED HEADS ARE <br />ACCEPTABLE IN THE BACK AREA. <br />2. FIRE SPRINKLER DESIGN SHALL BE PERFORMED BY A STATE LICENSED DESIGNER. <br />3. PAINT ALL DIFFUSERS AND GRILLS TO MATCH ADJACENT SURFACES. <br />4. BATTERY PACKS FOR EMERGENCY LIGHTS SHALL BE REMOTE OR RECESSED. <br />5. IF CEILING ACCESS PANELS ARE REQUIRED, PAINT TO MATCH ADJACENT SURFACE. <br />6. ALL TRACK LIGHTS MOUNTED ON P1 FINISH SHALL BE WHITE. <br />7. VERIFY LOCATIONS OF DEMISING WALLS, CLEAR HEIGHTS, COLUMNS, MALL FRONTS <br />AND ANY OTHER SIGNIFICANT COMPONENTS WITH THOSE INDICATED ON THE PLAN. <br />NOTIFY THE ARCHITECT OF ANY DIFFERENCES. <br />8. CEILING HEIGHTS INDICATED ON SHEET A-3 ARE INTENDED TO REPRESENT AN "IF <br />POSSIBLE" SCENARIO. IF THE EXISTING STRUCTURE, MAJOR DUCTWORK OR OTHER <br />OBSTRUCTIONS PROHIBIT THE REFERENCED HEIGHTS, PROVIDE AS MUCH HEIGHT AS <br />POSSIBLE, MAINTAINING A 6" DIFFERENCE FROM THE GYPSUM BOARD SURROUND TO <br />THE LAY -IN CEILING. NOTIFY THE ARCHITECT OF THE DIFFERENCES PRIOR TO <br />INSTALLATION. <br />Df VII+DN "I I=ARE <br />DIVISION 16 <br />SECTION 16720 - FIRE ALARM SYSTEM <br />A. GENERAL <br />1. CONDITIONS OF THE CONTRACT <br />A. THE GENERAL CONDITIONS AND SUPPLEMENTARY CONDITIONS SHALL APPLY TO AND FORM <br />PART OF THIS DIVISION. <br />2. SCOPE: <br />A. THIS SECTION INCLUDES ALL LABOR, MATERIAL, EQUIPMENT AND RELATED SERVICES <br />NECESSARY TO FURNISH, INSTALL AND CONNECT A COMPLETE FIRE ALARM SYSTEM. <br />B. A FIRE ALARM SYSTEM SHALL BE PROVIDED WHERE REQUIRED BY LOCAL CODES AND/OR <br />AS REQUIRED BY THE AHJ. <br />C. PROVIDE COMPLETE SYSTEM DESIGN AND SUBMITTAL INCLUDING PRODUCT DATA AND <br />SHOP DRAWINGS AND SUBMIT TO T-MOBILE FOR APPROVAL. UPON T-MOBILE APPROVAL, <br />SUBMIT TO THE AHJ FOR APPROVAL AND PERMIT. COORDINATE ALL INSPECTIONS AND <br />PERFORM SYSTEM TESTING PER THE AHJ REQUIREMENTS. <br />B. PRODUCTS <br />1. COMPLY WITH NFPA 72 AND THE NEC AS APPLICABLE TO CONSTRUCTION AND <br />INSTALLATION OF FIRE ALARM AND DETECTION SYSTEM COMPONENTS AND <br />ACCESSORIES. PROVIDE COMPONENTS AND SYSTEMS WHICH ARE UL LISTED AND <br />LABELED FOR FIRE ALARM. PROVIDE FIRE ALARM AND DETECTION SYSTEMS AND <br />ACCESSORIES WHICH ARE FM APPROVED. COMPLY WITH STATE AND LOCAL <br />REQUIREMENTS AS APPLICABLE. <br />1 IRE ALARfW C N DIVISION .6 F � "T <br />2. ACCEPTABLE MANUFACTURERS: EDWARDS, NOTIFIER, SIEMENS, SIMPLEX. WHERE <br />PART OF THE LANDLORD SYSTEM PROVIDE DEVICES MANUFACTURED BY AND <br />COMPATIBLE WITH LANDLORD SYSTEM. <br />3. WHERE PART OF THE LANDLORD SYSTEM PROVIDE DEVICES MANUFACTURED BY AND <br />COMPATIBLE WITH LANDLORD SYSTEM. COMPLY WITH ALL REQUIREMENTS AS <br />ESTABLISHED BY THE AHJ AND LANDLORD FOR TENANT SPACES. <br />4. THE SYSTEM SHALL OPERATE AS A LOW VOLTAGE, INTELLIGENT, POINT IDENTIFICATION <br />FIRE MANAGEMENT SYSTEM. THE FIRE DETECTION AND CONTROL SYSTEM SHALL <br />MONITOR INTELLIGENT (ANALOG) AND ADDRESSABLE (DIGITAL) DEVICES, TRADITIONAL <br />INITIATING DEVICES, POINT IDENTIFY THE ALARM LOCATION AND TRANSMIT A SIGNAL <br />TO THE MONITORING AGENCY. <br />5. AN ALARM SHALL BE DISPLAYED ON AN 80 CHARACTER ALPHANUMERIC DISPLAY AT <br />THE MAIN PANEL. WHEN REQUIRED BY THE AHJ, PROVIDE REMOTE 80 CHARACTER <br />KEYPAD ANNUNCIATOR AT APPROVED LOCATION. <br />6. PROVIDE REQUIRED INTERFACE CONNECTION TO FIRE SPRINKLER SYSTEM TAMPER <br />SWITCHES, FLOW SWITCHES AND HIGH/LOW AIR PRESSURE ALARM SWITCHES. <br />INCLUDE CONNECTION TO TAMPER SWITCHES IN EXTERIOR VAULTS. <br />7. PROVIDE CONNECTION FROM DUCT SMOKE DETECTORS TO FAN STARTER CONTROL <br />CIRCUIT. FANS SHALL BE SHUT DOWN ON LOCAL DETECTION ONLY. PROVIDE <br />INTERFACE RELAY TO CONTROL SYSTEM. <br />8. PROVIDE F.A. POWER AND FIRE CLOSURE SIGNAL CONNECTION TO ALL FIRE SHUTTERS <br />IN CORRIDORS. SHUTTERS SHALL BE POWERED FROM FIRE ALARM PANEL. <br />9. PROVIDE MANUAL STATIONS WHERE REQUIRED. MANUAL STATIONS SHALL BE DIE-CAST <br />ALUMINUM WITH WHITE LETTERING AND RED FINISH. EQUIP WITH PLASTIC GUARDS. <br />10. PROVIDE SMOKE DETECTORS WHERE REQUIRED. SMOKE DETECTORS SHALL BE <br />PHOTOELECTRIC TYPE WITH VISUAL INDICATION OF DETECTOR ACTUATION. <br />DETECTORS SHALL BE ADDRESSABLE AND INTELLIGENT TYPE. <br />11. DUCT SMOKE DETECTORS SHALL BE PHOTOELECTRIC TYPE AND SHALL OPERATE AT <br />AIR VELOCITIES OF 300 FEET PER MINUTE TO 2000 FEET PER MINUTE. AN INTEGRAL <br />FILTER SYSTEM SHALL BE INCLUDED TO REDUCE DUST AND RESIDUE ACCUMULATION. <br />AN AIR FLOW MONITOR SHALL BE INCLUDED TO INDICATE THE PRESENCE AND <br />DIRECTION OF AIR FLOW THROUGH THE DETECTOR. PROVIDE FOR ALL FAN SUPPLYING <br />AIR TO BUILDING WITH CFM TOTALS OF 2000 CFM OR GREATER. PROVIDE AT SUPPLY <br />AND/OR RETURN DUCT AS REQUIRED BY LOCAL CODE. <br />12. HORN/STROBES SHALL BE SOLID STATE CONSTRUCTION AND SHALL PRO <br />DUCE A <br />BROADBAND HORN SOUND OUTPUT OF 96 DBA (103 PEAK DBA) AT 10 FEET IN AN <br />ANECHOIC CHAMBER. THE STROBES SHALL PRODUCE 8000 PEAK CANDLEPOWER AT <br />ONE FLASH PER SECOND. <br />C. EXECUTION: <br />1. INSTALLATION: <br />a. PROVIDE THE SYSTEM IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS, ALL <br />APPLICABLE CODES AND THE MANUFACTURER'S RECOMMENDATIONS. ALL WIRING SHALL <br />BE INSTALLED IN STRICT COMPLIANCE WITH ALL THE PROVISIONS OF NEC: ARTICLE 760 A <br />AND C, POWER -LIMITED FIRE PROTECTIVE SIGNALING CIRCUITS OR, IF REQUIRED, MAY BE <br />RECLASSIFIED AS NON -POWER LIMITED AND WIRED IN ACCORDANCE WITH NEC: ARTICLE <br />760 A AND B. UPON COMPLETION, THE CONTRACTOR SHALL SO CERTIFY IN WRITING TO <br />T-MOBILE AND GENERAL CONTRACTOR. <br />b. THE SUPPLIER SHALL HAVE THE CAPABILITIES OF RESPONDING TO A SERVICE CALL WITH <br />A FACTORY TRAINED TECHNICAL REPRESENTATIVE WITHIN 24 HOURS. ALSO, THIS <br />SUPPLIER SHALL MAINTAIN AN ADEQUATE STOCK OF ALL PARTS NECESSARY FOR THE <br />REPAIR OF THIS EQUIPMENT ON HAND AT ALL TIMES. <br />c. THE SYSTEM, UPON COMPLETION OF INSTALLATION BY THE CONTRACTOR, SHALL BE <br />CHECKED OUT AND ALL CONNECTIONS TO INITIATING AND INDICATING DEVICES SHALL BE <br />SUPERVISED BY FACTORY TRAINED TECHNICIANS IN THE EMPLOY OF A FACTORY <br />FRANCHISED DEALER FOR THE PRODUCT INSTALLED. EACH INDIVIDUAL DEVICE SHALL BE <br />CHECKED OUT AND TESTED FOR OPERATION BY A FACTORY TRAINED TECHNICIAN. <br />d. THE COMPLETED FIRE ALARM SYSTEM SHALL BE FULLY TESTED IN ACCORDANCE WITH <br />NFPA 72H BY THE CONTRACTOR IN THE PRESENCE OF T-MOBILE'S REPRESENTATIVE AND <br />THE LOCAL FIRE MARSHAL. UPON COMPLETION OF A SUCCESSFUL TEST, THE <br />CONTRACTOR SHALL SO CERTIFY IN WRITING TO T-MOBILE. <br />Mobi'le'D <br />12920 SE 38th STREET <br />BELLEVUE, WA 98006 <br />www.T-Mobile.com <br />COPYRIGHT NOTICE <br />THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO <br />COPYRIGHT PROTECTION AS AN'ARCHITECTURAL WORK" UNDER SEC. 102 OF <br />THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED JANUARY 2003. THE PROTECTION <br />INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND <br />COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH <br />PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS <br />MAY RESULT IN CESSATION OF CONSTRUCTION, BUILDING SEIZURE, AND/OR <br />MONETARY LIABILITY. <br />ARCHITECT <br />rmUzioN <br />9096 EAST BAHIA DRIVE <br />SUITE 103 <br />SCOTTSDALE, AZ 85260 <br />DESIGN@FUZIONVE.COM <br />WWW.FUZIONVE.COM <br />VENDOR PROJECT NO: 21,11.212680 <br />O F F(0 ' <br />a! • ��PM LOUIS P1 <br />✓C <br />ti, <br />ReD AR <br />02/10/2022 <br />CONSULTING ENGINEER <br />N <br />W <br />Q <br />Q r <br />Z ! M <br />W <br />C� W J <br />J = � <br />V O J <br />m J <br />0 <br />W J = <br />00 <br />� N W <br />-tiN <br />J <br />J <br />,Q <br />V <br />DATE: February 5, 2022 <br />SCALE: AS NOTED <br />DRAWN BY: LEO V. <br />SAP NUMBER: <br />4SIR <br />CORPORATE TENANT REBUILD <br />LDC <br />SHEET TITLE: <br />SPECIFICATIONS <br />4 <br />3 <br />M <br />1 <br />SHEET NUMBER: <br />