Laserfiche WebLink
DRAWING I-NDEX- <br />GENERAL- <br />CVR COVER SHEET <br />01.1 BID NOTES <br />F1.0 FIXTURE PLAN (DO NOT BID) <br />L1.0 LIFE SAFETY PLAN <br />ARCHITECTURAL <br />SP1.0 ARCH SITE PLAN <br />D1.0 DEMOLITION PLAN <br />A1.0 FLOOR PLAN <br />A1.1 ENLARGED RESTROOM PLANS AND DETAILS <br />A1.2 ENLARGED PLANS AND DETAILS <br />A2.0 REFLECTED CEILING PLAN <br />A3.0 BUILDING ELEVATIONS AND DETAILS <br />A4.0 ROOF PLAN <br />A5.0 WALL SECTIONS <br />A5.1 ARCH DETAILS <br />A6.0 DETAILS <br />A6.1 PEGBOARD DETAILS <br />A7.0 WALL TYPES AND DETAILS <br />A8.0 DOOR SCHEDULE AND DETAILS <br />A8.1 SCHEDULES <br />STRUCTURAL- <br />ELECTRICAL- <br />SO.0 GENERAL NOTES <br />E1.0 <br />LIGHTING PLAN <br />S1.0 FOUNDATION PLAN <br />E1.1 <br />ENLARGED LIGHTING PLANS <br />S2.0 FRAMING PLANS <br />E2.0 <br />POWER PLAN <br />S2.1 DETAILS <br />E2.1 <br />ENLARGED POWER PLANS <br />E3.0 <br />ELECTRICAL DETAILS <br />PLUMBING <br />E4.0 <br />ELECTRICAL DETAILS <br />E5.0 <br />ELECTRICAL RISER AND SCHEDULES <br />P1.0 PLUMBING PLAN <br />E5.1 <br />ELECTRICAL SCHEDULES <br />P1.I ENLARGED PLUMBING PLANS <br />E6.0 <br />TELECOM PLAN <br />P2.0 PLUMBING SCHEDULES AND DETAILS <br />E7.0 <br />AUDIO PLAN <br />MECHANICAL- <br />M1.0 <br />MECHANICAL PLAN <br />M1.1 <br />ROOF PLAN <br />M1.2 <br />ENLARGED MECHANICAL PLANS <br />M2.0 <br />MECHANICAL DETAILS <br />M3.0 <br />MECHANICAL SCHEDULES <br />BUILDING CODE SUMMARY <br />NAME OF PROJECT: <br />ZEPHYRHILLS, <br />FLORIDA <br />STREET ADDRESS: <br />7333 GALL BOULEVARD <br />PROPOSED USE: <br />RETAIL <br />CODES: BUILDING CODE <br />2010 FLORIDA <br />BUILDING <br />CODE <br />PLUMBING CODE <br />2010 FLORIDA <br />BUILDING <br />CODE, PLUMBING <br />MECHANICAL CODE <br />2010 FLORIDA <br />BUILDING <br />CODE, MECHANICAL <br />FUEL GAS CODE <br />2010 FLORIDA <br />BUILDING <br />CODE, FUEL GAS <br />ELECTRICAL CODE <br />2011 NATIONAL <br />ELECTRICAL CODE <br />FIRE CODE <br />FLORIDA FIRE <br />PREVENTION CODE <br />ENERGY CODE <br />2010 FLORIDA <br />BUILDING <br />CODE, ENERGY CONSERVATION <br />ACCESSIBILITY: ACCESSIBILITY <br />OCCUPANCY: <br />TYPE OF CONSTRUCTION: <br />ALLOWABLE AREA: <br />MERCANTILE: <br />ASSEMBLY (1 <br />PER 15): <br />STORAGE (1 <br />PER 300): <br />BUSINESS (1 <br />PER 100): <br />MERCANTILE <br />(1 PER 30) <br />MEZZANINE (1 <br />PER 300) <br />TOTAL: <br />IIB (SPRINKLERED) <br />57,250 <br />2010 FLORIDA BUILDING CODE, ACCESSIBILITY <br />345 S.F. = 23 OCCUPANT LOAD = 5 INCHES REQUIRED <br />2,035 S.F. = 7 OCCUPANT LOAD = 2 INCHES REQUIRED <br />1,822 S.F. = 19 OCCUPANT LOAD = 4 INCHES REQUIRED <br />41,813 S.F. = 1,394 OCCUPANT LOAD = 279 INCHES REQUIRED <br />2,548 S.F. = 9 OCCUPANT LOAD = 3 INCHES REQUIRED <br />48,564 S.F. 1,635 OCCUPANT LOAD 292 INCHES REQUIRED <br />500 INCHES PROVIDED <br />SECTION 506 <br />FIRE PROTECTION: BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM <br />IN ACCORDANCE WITH SECTION 903.3.1.1 <br />EXTERIOR BEARING WALLS 0 <br />STRUCTURAL FRAME 0 <br />ROOF/CEILING CONSTRUCTION 0 <br />INTERIOR BEARING AND NON -BEARING PARTITIONS 0 <br />COLUMNS 0 <br />PLUMBING FIXTURE COUNT: 2010 FLORIDA BUILDING CODE, PLUMBING <br />WATER CLOSETS: REQUIRED PROVIDED <br />FEMALE 2 4 <br />MALE 2 2 <br />URINALS: <br />MALE 0 2 <br />LAVATORIES: <br />FEMALE 2 3 <br />MALE 2 3 <br />DRINKING FOUNTAINS: <br />ALL 2 2 <br />SERVICE SINK: <br />ALL WOOD MATERIALS SHOWN IN DETAILS IN THESE DRAWINGS SHALL BE <br />FIRE RETARDANT TREATED WOOD(FRTW) IN ACCORDANCE WITH FBC <br />SECTION 603.1. THIS INCLUDES ALL REFERENCES TO "BLOCKING", <br />"NAILERS", "PLYWOOD", "SHEATHING" AND IF APPLICABLE "WOOD STUDS". <br />GENERAL REQUIREMENTS <br />EXTENT OF THE WORK: <br />• THE SPECIFICATIONS AND DRAWINGS COVER THE COMPLETE CONSTRUCTION <br />SCOPE. THEY ARE INTENDED TO BE COMPLEMENTARY AND ANYTHING <br />MENTIONED OR IMPLIED BY ONE WILL BE CONSIDERED TO BE INCLUDED AS <br />THOUGH MENTIONED BY ALL. <br />CODES, PERMITS, LAWS, ETC.: <br />• COMPLY WITH ALL FEDERAL, STATE, AND MUNICIPAL LAWS, CODES, <br />ORDINANCES APPLICABLE TO THE WORK AND ALL REQUIREMENTS OF THE <br />NATIONAL BOARD OF FIRE UNDERWRITERS HAVING JURISDICTION. IF THE ABOVE <br />LAWS, CODES, OR ORDINANCES CONFLICT WITH THE SPECIFICATIONS, THE LAWS, <br />ETC., SHALL GOVERN, EXCEPT WHERE THE SPECIFICATIONS EXCEED THEM IN <br />QUALITY OR QUANTITY OF LABOR OR MATERIALS. THE SUBCONTRACTOR WILL <br />OBTAIN AND PAY FOR ALL PERMITS REQUIRED IN CONNECTION WITH THE <br />EXECUTION OF HIS WORK. <br />SAFETY: <br />• IT IS THE POLICY OF HOBBY LOBBY STORES, INC. TO, AT ALL TIMES, PROVIDE <br />SAFE WORK ENVIRONMENTS, CONDUCT ALL OPERATIONS IN A MANNER THAT <br />ELIMINATES RISK TO ANY TRADES PERSON, MAINTAIN ALL CONDITIONS IN A <br />WAY THAT ELIMINATES ALL RISK TO VISITORS AND TO THE PUBLIC, AND <br />ELIMINATE THE RISK OF DAMAGE TO PROPERTY ON AND ADJACENT TO THE <br />SI TE. <br />• THIS IS THE FUNDAMENTAL RESPONSIBILITY OF EVERY INDIVIDUAL ON THE SITE. <br />ALL SUPERVISORS MUST ACCEPT COMPLETE RESPONSIBILITY FOR PREVENTION <br />OF ACCIDENTS AND FOR SAFETY OF ALL WORK UNDER THEIR DIRECTION. <br />• BY CONTRACT AND BY LAW, EVERY COMPANY ON THE SITE IS AT A MINIMUM <br />TO CONFORM TO THE FEDERAL OCCUPATIONAL SAFETY AND HEALTH ACT, AND <br />TO THE LAWS OF EVERY ENTITY HAVING JURISDICTION OVER THE WORK. <br />• ANY COMPANY OR INDIVIDUAL REFUSING TO CORRECT OBSERVED SAFETY <br />VIOLATIONS WILL BE BANNED FROM THE SITE AT LEAST UNTIL SUCH <br />VIOLATIONS ARE CORRECTED, AND WILL BE HELD COMPLETELY RESPONSIBLE <br />FOR ALL RESULTING EFFECTS. <br />HAZARDOUS MATERIALS: <br />• IN THE EVENT A SUB -CONTRACTOR DISCOVERS, AT ANY TIME DURING <br />DEMOLITION, CONSTRUCTION, AND OR REMODELING OPERATIONS, EXISTING <br />CONDITIONS THAT COULD INCLUDE THE PRESENCE OF MOLD, MILDEW, <br />ASBESTOS, OR ANY HAZARDOUS MATERIAL, THE SUB -CONTRACTOR SHALL <br />IMMEDIATELY NOTIFY THE OWNER'S REPRESENTATIVE AND ARCHITECT/ENGINEER <br />OF RECORD, IN WRITING, OF THE CONCERNS AND OR SUSPICIONS. <br />• ONCE DISCOVERY OR SUSPICION OF MOLD, MILDEW, ASBESTOS, OR ANY <br />HAZARDOUS MATERIAL IS MADE, THE SUB -CONTRACTOR SHALL TAKE ALL <br />REASONABLE AND PRACTICAL PRECAUTIONS TO PROTECT ALL CONSTRUCTION <br />PERSONNEL AND THE PUBLIC FROM THE EXPOSURE TO ANY HAZARDOUS <br />MATERIAL AND SUCH PRECAUTIONS SHALL REMAIN IN PLACE UNTIL SUCH TIME <br />AS THE OWNER OR HEALTH AUTHORITY DIRECTS OTHERWISE. CONSTRUCTION <br />OPERATIONS SHALL NOT BE STOPPED OR CURTAILED, EXCEPT IN THE AREA OF <br />MOLD THE HAZARDOUS MATERIAL CONCERN DUE TO THESE REQUIRED <br />PRECAUTIONS. <br />• THE SUB -CONTRACTOR SHALL MAKE ALL REASONABLE EFFORTS TO AVOID <br />CONDITIONS FAVORABLE TO THE DEVELOPMENT OF MOLD AND MILDEW, <br />ESPECIALLY IN VOIDS WHICH WILL BE CONCEALED AND NOT VENTILATED. IN <br />ALL CASES, INTERIOR SPACES AND INTERIOR FINISHED CONSTRUCTION SHALL <br />BE MAINTAINED IN DRY AND WELL -VENTILATED CONDITIONS. <br />• THE SUB -CONTRACTOR SHALL COMPLY WITH FEDERAL ENVIRONMENTAL AND <br />OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION REGULATIONS AND ALL <br />LOCAL AND STATE HEALTH DEPARTMENT REQUIREMENTS AND <br />RECOMMENDATIONS REGARDING MOLD, MILDEW, ASBESTOS, OR ANY HAZARDOUS <br />MATERIAL. <br />CONFLICTS IN DOCUMENTS AND CONDITIONS: <br />• THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE CONTRACT <br />DOCUMENTS WITH EACH OTHER AND SHALL REPORT IMMEDIATELY TO THE <br />SUPERINTENDENT ERRORS, INCONSISTENCIES OR OMISSIONS DISCOVERED. IF THE <br />SUB -CONTRACTOR PERFORMS ANY WORK KNOWING IT INVOLVES A RECOGNIZED <br />ERROR, INCONSISTENCY OR OMISSION IN THE CONTRACT DOCUMENTS WITHOUT <br />IMMEDIATE NOTICE TO THE SUPERINTENDENT, THE SUB CONTRACTOR SHALL <br />ASSUME APPROPRIATE RESPONSIBILITY FOR SUCH PERFORMANCE AND SHALL <br />BEAR AN APPROPRIATE AMOUNT OF THE ATTRIBUTABLE COSTS FOR <br />CORRECTION. <br />• THE SUB CONTRACTOR SHALL TAKE FIELD MEASUREMENTS AND VERIFY FIELD <br />CONDITIONS AND SHALL CAREFULLY COMPARE SUCH FIELD MEASUREMENTS <br />AND CONDITIONS AND OTHER INFORMATION KNOWN TO THE SUB CONTRACTOR <br />WITH THE CONTRACT DOCUMENTS BEFORE COMMENCING ACTIVITIES. ERRORS, <br />INCONSISTENCIES OR OMISSIONS DISCOVERED SHALL BE REPORTED TO THE <br />SUPERINTENDENT AT ONCE. <br />• THE SUB CONTRACTOR SHALL PERFORM THE WORK IN ACCORDANCE WITH THE <br />CONTRACT DOCUMENTS AND SUBMITTALS APPROVED BY THE GENERAL <br />CONTRACTOR. THE SUB CONTRACTOR SHALL PERFORM NO PORTION OF THE <br />WORK AT ANY TIME WITHOUT CONTRACT DOCUMENTS OR, WHERE REQUIRED, <br />APPROVED SHOP DRAWINGS, PRODUCT DATA, OR SAMPLES FOR SUCH PORTION <br />OF THE WORK. <br />HOBBY LOBBY CONTACTS <br />RESPONSIBILITIES <br />CONTACT <br />PHONE/FAX/EMAIL <br />STOCKROOM DOORS, FLOOR <br />HOBBY LOBBY <br />P (405) 745-1651 <br />BALE LIFT, LIGHT <br />7707 S.W. <br />44TH STREETTILE, <br />F (405) 745-1634 <br />FIXTURES, PEGBOARD, AND <br />OKLAHOMA CITY, OK 73179 <br />kimberly.slocum@hobby <br />PLUG MOLD DISPLAYS. <br />ATTN.: KIM SLOCUM <br />lobby.com <br />PERMITTING <br />HOBBY LOBBY <br />P (405) 745-1610 <br />7707 S.W. 44TH STREET <br />F (405) 745-1772 <br />OKLAHOMA CITY, OK 73179 <br />lonnie.glidewell@hobbylobby.com <br />ATTN.: LONNIE GLIDEWELL <br />FIRE ALARMS <br />HOBBY LOBBY <br />P (405) 745-1548 <br />7707 S.W. 44TH STREET <br />F (405) 745-1634 <br />OKLAHOMA CITY, OK 73179 <br />rebecca.shingler@hobbylobby.com <br />ATTN.: REBECCA SHINGLER <br />COMPACTOR SYSTEMS <br />HOBBY LOBBY <br />P (405) 745-1351 <br />7707 S.W. 44TH STREET <br />F (405) 745-1637 <br />OKLAHOMA CITY, OK 73179 <br />jack. johnston@hobbylobby.com <br />ATTN.: JACK JOHNSTON <br />SIGNAGE <br />HOBBY LOBBY <br />P (405) 745-1178 <br />7707 S.W. 44TH STREET <br />F (405) 745-1855 <br />OKLAHOMA CITY, OK 73179 <br />larry.hostetter@hobbylobby.com <br />ATTN.: LARRY HOSTETTER <br />HVAC EQUIPMENT BUYER <br />HOBBY LOBBY <br />P (405) 745-1237 <br />7707 S.W. 44TH STREET <br />F (405) 745-1634 <br />OKLAHOMA CITY, OK 73179 <br />joson.snook@hobbylobby.com <br />ATTN.: JASON SNOOK <br />UTILITY COORDINATION <br />HOBBY LOBBY <br />P (405) 745-1791 <br />7707 S.W. 44TH STREET <br />F (405) 745-1634 <br />OKLAHOMA CITY, OK 73179 <br />terry.jack@hobbylobby.com <br />ATTN.: TERRY JACK <br />TELECOMMUNICATIONS <br />HOBBY LOBBY <br />P (405) 745-1687 <br />7707 S.W. 44TH STREET <br />F (405) 745-1776 <br />OKLAHOMA CITY, OK 73179 <br />scott.them el@hobbylobby.corn <br />ATTN.: SCOTT DIEMEL <br />BUILDING AUTOMATION <br />HOBBY LOBBY <br />P (405) 745-1237 <br />SYSTEMS <br />7707 S.W. 44TH STREET <br />F (405) 745-1634 <br />OKLAHOMA CITY, OK 73179 <br />joson.snook@hobbylobby.com <br />ATTN.: JASON SNOOK <br />SUPPLIER CONTACTS <br />ITEMS SUPPLIED <br />CONTACT <br />PHONE/ FAX <br />ELECTRICAL DISTRIBUTION <br />CAROLINA PRODUCTS, INC. <br />P <br />(704) <br />364-9029 <br />SYSTEM <br />1132 PRO AM DRIVE <br />F <br />(704) <br />367-1215 <br />CHARLOTTE, NC 28211 <br />ATTN.: CHRISTA <br />TOILET PARTITIONS, GRAB <br />Y.I. SPECIALTIES, INC. <br />P <br />(704) <br />364-9029 <br />BARS AND MIRRORS <br />13801 S. SOONER ROAD <br />F <br />(704) <br />367-1215 <br />EDMOND, OK 73034 <br />ATTN.: RUDY YOUNG <br />SLIDING GLASS DOORS <br />NABCO ENTRANCES, INC. <br />P <br />(262) <br />679-7514 <br />S81 W18717 GEMINI DRIVE <br />F <br />(888) <br />679-3319 <br />MUSKEGO, WI 53150 <br />ATTN.: JAN GRABOWSKI <br />STANDARD DOORS AND <br />GIRTMAN AND ASSOCIATES <br />P <br />(615) <br />350-6000 <br />HARDWARE <br />7115 COCKRILL BEND BLVD. <br />F <br />(615) <br />350-6686 <br />NASHVILLE, TN 37209 <br />ATTN.: JENNIFER WONSON <br />DEFERRED SUBMITTALS <br />SUBMITTALS <br />RESPONSIBLE PARTY <br />FIRE SPRINKLER MODIFICATIONS <br />INSTALLER <br />FIRE ALARM MODIFICATIONS <br />CONSULTANT <br />Jk_ V2;MITi"ES PLAN(IS) RAVE 9EEti rS,'W?EWi& <br />�F THY �iI :I,S FIRE �A' RSHAL; 6 OFFICE <br />Please be advised this review of plans submitted is a <br />cursory review to assist the cone; actor in compliance with <br />applicable fire safety codes. This review is not intended <br />to be a final approval of the submitted plans. It is the <br />contractor's sole responsibility to ensure that'he plans are in <br />complete compliance with all �,,p,pli„able t FPA codes and <br />local ordinances. In tine event t ;20, or <br />site inspection reveals areasall be <br />the contractor's sole responsib ,ty at their sole expense to <br />bring those areas in compliance. The Oity asssi les no <br />responsibility for the contractor's failure to be in compliance <br />with all applicable NFPA Lodes and local ordinances. <br />ALL'�1 ORK SHALL CJJ1i'L�' %G i [If ;LI_, <br />PRE\V'AILING CODES, FLORIDA BUILDING <br />CODE,1,"ATIONAL ELECTRIC CODE AND <br />CITY OF ZL:i'HYR11ILLS ORDINANCES <br />REVIEW DATE_ <br />:_IT', OF ZEPHYRHIL! ,c <br />FLANS EXAMINER <br />ALL 0 1 <br />OWNER: <br />AUTHORITY HAVING JURISDICTION: <br />HOBBY LOBBY STORES, INC. <br />CITY OF ZEPHYRHILLS <br />7707 S.W. 44TH ST. <br />5335 8TH STREET <br />OKLAHOMA CITY, OK 73179 <br />ZEPHYRHILLS, FLORIDA 33542 <br />CIVIL: <br />ARCHITECT: <br />STRUCTURAL: <br />MECHANICAL: <br />ELECTRICAL: <br />FIRE PROTECTION AND ALARM: <br />NOT PART OF THESE DOCUMENTS <br />pb2 architecture + engineering <br />710 WEST ROSELAWN DRIVE <br />METTEMEYER ENGINEERING L.L.C. <br />2101 WEST CHESTERFIELD BOULEVARD, B-105 <br />pb2 architecture + engineering <br />710 WEST ROSELAWN DRIVE <br />pb2 architecture + engineering <br />710 WEST ROSELAWN DRIVE <br />NOT PART OF THESE DOCUMENTS <br />ROGERS, ARKANSAS 72756 <br />SPRINGFIELD, MISSOURI 65807 <br />ROGERS, ARKANSAS 72756 <br />ROGERS, ARKANSAS 72756 <br />Y <br />p+enbf_� <br />hitecture <br />gineering <br />710 West Roselawn Drive <br />Rogers, Arkansas 72756 <br />Phone: 479.636.3545 <br />Fax: 479.636.1209 <br />William Douglas Hurley <br />Florida License No rR91919 <br />Firm License No: AA26000940 <br />w wwo <br />� W H <br />N <br />0 V)HZ� 0Q_ <br />Z 2' F O W V) N W Z <br />W O F�-0LW ajUW0¢a <br />z of <br />Qa~Oa00V)=ZQWS <br />d Da 0 UOZiEH <br />KF,<>_4Za Ua2<U0020 <br />11 d pJOw:0 <br />Q W � � � <br />ZO 3W[ Ds0D0oW=Waw�Q <br />0 a-Z X5w <br />I- ZV)VjQ DOno_XWW <br />ZZ <br />O0VQ Q0O VQ_ <br />J ZZ UWWU W U aaO.t:WV)wZ03oom <br />�Dn0=a�adoaW- <br />() on�w <br />>M <br />I <br />I <br />a Q <br />0�_ <br />W� <br />J O <br />00J <br />mJ <br />>M <br />W Q� <br />ra <br />111 <br />MNC\2 <br />ti <br />0 <br />ISSUE BLOCK <br />CHECKED BY: <br />DF <br />DRAWN BY: <br />JCF <br />FILE NAME: <br />CVR <br />DOCUMENT DATE: <br />08-09-13 <br />COVER <br />SHEET <br />SHEET: <br />CVR <br />