<br />SCOPE OF WORK FOR ALL DISCIPLINES
<br />ITEMS TO INCLUDE IN YOUR BID IF NOT ALREADY NOTED ON PLANS:
<br />• CONTRACTOR TO WALK THE SITE WITH THE HOBBY LOBBY ON -SITE
<br />SUPERINTENDENT AND VERIFY ALL EXISTING CONDITIONS PRIOR TO BID.
<br />• INCLUDE LABOR IN JOB TO COMPLETE YOUR SCOPE OF WORK IN THE TIME
<br />ALLOWED BY FIELD SUPERINTENDENT.
<br />• CLEAN UP DAILY OR MORE OFTEN IF NECESSARY TO KEEP SITE CLEAN AND
<br />SAFE.
<br />• CONTRACTOR TO SUPPLY AS -BUILT DRAWINGS AT COMPLETION OF PROJECT.
<br />• ALL INFORMATION WILL BE PROVIDED TO ON -SITE SUPERINTENDENT OR THEIR
<br />REPRESENTATIVE.
<br />• CONTRACTOR TO BID COMPLETE SET OF DRAWINGS / ALL SHEETS.
<br />• SUBCONTRACTOR MUST PROVIDE PAYMENT AND PERFORMANCE BOND FOR ANY
<br />WORK OVER $100,000.00. CONTRACTOR TO SHOW BOND PRICE IN BID. BOND
<br />MUST BE RECEIVED BY HOBBY LOBBY WITH IN 5 BUSINESS DAYS AFTER
<br />CONTRACT RECEIVED.
<br />• CONTRACTOR MUST INCLUDE AND SHOW SALES TAX ON BIDS.
<br />• CONTRACTOR IS TO PLACE ALL DEBRIS IN THE G.C. PROVIDED DUMPSTER.
<br />DRYWALL AND FRAMING
<br />ITEMS TO INCLUDE IN YOUR BID IF NOT ALREADY NOTED ON PLANS:
<br />• A MINIMUM OF 20 GAUGE METAL TO BE USED ON ALL FRAMING COMPONENTS.
<br />• REFER TO PLANS FOR LOCATIONS OF HEAVIER GAUGE METALS TO BE USED.
<br />• DRYWALL TO BE 5/8" TYPE X, UNLESS NOTED OTHERWISE, TAPED, BEDDED WITH
<br />MEDIUM KNOCK DOWN TEXTURE READY FOR PAINT.
<br />• 5/8" GREEN BOARD OR "M.R.S." (MOISTURE RESISTANT SHEET ROCK) IN REST
<br />ROOMS ON WALLS THAT ARE WITHIN 4'-O" OF ANY PLUMBING FIXTURES.
<br />• FURNISH AND INSTALL F.R.P., GLUE MUST BE APPLIED WITH A TROWEL NO
<br />EXCEPTIONS. INSTALL F.R.P. CORNERS, JOINTS AND CEILING TRIM CUT TRIM 4"
<br />ABOVE FINISH FLOOR FOR COVE BASE INSTALLATION. WHERE APPLICABLE AS
<br />SHOWN ON PLANS.
<br />• CEILING TILE TO BE ARMSTRONG 2911 PROVIDED BY G.C.
<br />• SUBCONTRACTOR TO FURNISH AND INSTALL VINYL CLAD DRYWALL CEILING TILE.
<br />• HARD CEILING AND METAL DECKS TO BE TIED TO ROOF STRUCTURE WITH CEILING
<br />WIRE AND 1 1 /2" COLD ROLLED STEEL. USE STRUCTURAL GAUGE METAL DECKING
<br />ABOVE CASH OFFICE.
<br />• CHECK LOCAL CODES FOR SPECIAL CONDITIONS ON CEILING GRID INSTALLATION.
<br />• FURNISH LABOR TO INSTALL DOORS, JAMBS AND HARDWARE.
<br />• FURNISH LABOR TO INSTALL O.S.B. WAINSCOT IN WAREHOUSE.
<br />• FURNISH AND INSTALL WOOD BACKING AT DOOR JAMBS, TOILET PARTITIONS,
<br />BABY CHANGING STATION, T.V., TOILET ACCESSORIES, CABINETS, STORE FRONT,
<br />AND SIGNAGE IF APPLICABLE.
<br />• FURNISH AND INSTALL WOOD BLOCKING AND CORNICE FRAMING AT TOP OF
<br />PARAPET WALLS IF SHOWN ON PLANS. (ALTERNATE PROPOSAL)
<br />• INSTALLATION OF RESTROOM PARTITIONS AND ALL TOILET ACCESSORIES.
<br />• INCLUDE CEILING GRID IN DRYWALL PROPOSAL.
<br />• INCLUDE ALL EXTERIOR FRAMING, SHEATHING, AND MOISTURE BARRIER ON ALL
<br />EXTERIOR FRAMEWORK.
<br />• USE FIRE RATED CAULKING ON FIRE RATED WALLS, WHERE REQUIRED.
<br />• INSULATE ALL WALLS BELOW CEILING GRID BETWEEN OFFICES, RETAIL, AND
<br />RESTROOM WALLS ADJACENT TO STAGING AREA AS SHOWN ON PLANS.
<br />• LABOR AND FASTENERS TO INSTALL G.C. SUPPLIED CABINETS AND SHELVING.
<br />• FURNISH AND INSTALL CEILING WIRE AT ALL LIGHT FIXTURE CEILING BRACKETS.
<br />COORDINATE EXACT LOCATION WITH ELECTRICIAN.
<br />PLUMBING
<br />ITEMS TO INCLUDE IN YOUR BID IF NOT ALREADY NOTED ON PLANS:
<br />• SAW CUTTING AND REMOVAL OF CONCRETE SLAB AS NEEDED FOR NEW IN
<br />GROUND PLUMBING. REPLACE WITH CONCRETE OF EQUAL DEPTH AND STRENGTH,
<br />DOWEL EDGES OF SLAB 16" O.C. USING 1 /2" X 2' REBAR.
<br />• CAP ALL UNUSED PLUMBING LINES A MINIMUM OF 4" BELOW FINISH FLOOR, NO
<br />CONCRETE TO BE POURED INTO ABANDONED LINES.
<br />• CAMERA ALL NEW LINES AT COMPLETION OF JOB ON GROUND UP CONSTRUCTION.
<br />CAMERA ALL EXISTING LINES AT BEGINNING AND END OF JOBS TO BE REUSED.
<br />PROVIDE TAPE OR DVD TO GENERAL CONTRACTOR.
<br />• HOT WATER TANK TO BE ELECTRIC AS SPECIFIED.
<br />CONTRACTOR TO INSTALL CONDENSATE LINES IF NECESSARY.
<br />• HANDICAP SINKS TO RECEIVE WRAPPING ON EXPOSED PIPING PER CODE.
<br />• CAP ALL WATER LINES THAT ARE ABANDONED AND REMOVE ALL ABANDONED
<br />PIPING.
<br />• PROVIDE TRAP PRIMERS ON ALL FLOOR DRAINS.
<br />• IF PLANS INDICATE PRESSURE ASSIST TANKS ON WATER CLOSETS VERIFY THAT
<br />THE HANDICAP HAVE THE SAME.
<br />• GAS PIPING ON ROOF TO BE FASTENED DOWN TO APPROVED OR SPECIFIED
<br />BLOCKING.
<br />• IF A HIGH PRESSURE GAS LINE SYSTEM IS USED THE REGULATORS AND
<br />SHUT-OFF VALVES WILL BE FURNISHED BY GAS PIPE INSTALLER.
<br />• IDENTIFY LOCATION OF GAS, WATER AND IRRIGATION SERVICE AND METERS.
<br />• CONFIRM NO CROSS CONNECTIONS ON NATURAL GAS SYSTEM OR WATER TO
<br />ADJACENT SPACES IF APPLICABLE.
<br />• IDENTIFY ANY SUB -METERS INSTALLED ON WATER SYSTEM AND DESCRIBE THEIR
<br />PURPOSE.
<br />• IDENTIFY LOCATION OF ALL BACK -FLOW PREVENTERS, I.E. FIRE SYSTEMS,
<br />IRRIGATION, DOMESTIC WATER, ETC. AND TESTING IF APPLICABLE.
<br />• SUBMITTALS FOR ANY NEW FIXTURES AND EQUIPMENT TO BE SUPPLIED TO
<br />HOBBY LOBBY PRIOR TO INSTALLATION.
<br />• SUBCONTRACTOR TO DO ALL EXCAVATING, COMPACTING AND BACK FILLING
<br />NECESSARY.
<br />• SUBCONTRACTOR RESPONSIBLE FOR ALL BACKING NECESSARY TO COMPLETE HIS
<br />WORK.
<br />PLUMBING (GROUND UP)
<br />• ALL PIPES SHALL BE CUT OFF AT LEAST 1" BELOW FINISH FLOOR WITH A
<br />COUPLING TO TIE INTO AND EXTEND UP AFTER FLOOR AND WALLS HAVE BEEN
<br />POURED.
<br />• PLACE 12" SONA-TUBE AROUND EACH PIPE FILLED WITH SAND TO 1" BELOW
<br />FINISH FLOOR.
<br />• AFTER WALLS HAVE BEEN ERECTED LOCATE ALL PIPES AND BREAK OUT
<br />CONCRETE COVERING THEM AND EXTEND UP ABOVE FLOOR.
<br />• ALL WATER LINES SHALL BE COPPER AND RAN OVERHEAD.
<br />• ALL WATER LINES SHALL BE HUNG ON APPROVED HANGERS AND INSULATED.
<br />• ALL PVC SHALL BE SCHEDULE 40.
<br />CONCRETE
<br />ITEMS TO INCLUDE IN YOUR BID IF NOT ALREADY NOTED ON PLANS:
<br />• CONTRACTOR TO SUPPLY HOBBY LOBBY WITH MIX DESIGN OF CONCRETE FROM
<br />SUPPLIER OR SUPPLIERS PRIOR TO THE POURING OF ANY CONCRETE. ALLOW 2
<br />WEEKS LEAD TIME FOR ENGINEERS APPROVAL.
<br />• IF CONTRACTOR USES ANY COMPANY OR INDIVIDUAL AS A SUBCONTRACTOR TO
<br />COMPLETE ANY PORTION OF THEIR CONTRACT, THEY MUST NOTIFY HOBBY LOBBY
<br />WITH PROOF OF THEIR INSURANCE PRIOR TO DOING ANY WORK ON THE JOB.
<br />• CONTRACTOR TO SUPPLY AND INSTALL ALL STEEL REINFORCEMENT TO BE USED
<br />ON THIS PROJECT. CONTRACTOR IS RESPONSIBLE FOR ANY FABRICATION TO
<br />FORM INTO SHAPES AND LENGTHS REQUIRED.
<br />• CONTRACTOR TO SUPPLY ALL CONCRETE, MATERIALS, AND LABOR TO COMPLETE
<br />THIS PROJECT. (ANY EXCLUSION MUST BE NOTED ON CONTRACT)
<br />• G.C. WILL HAVE A SURVEYOR SET PINS FOR BUILDING CORNERS, PIERS, BACK OF
<br />CURBS, LIGHT POLE BASES, LOADING DOCK WALLS AND REFERENCE FOR OTHER
<br />POINTS ALONG WITH ELEVATIONS. IT IS THE CONTRACTORS RESPONSIBILITY TO
<br />SET BATTER BOARDS OR LINES FOR OTHER TRADES TO USE TO ESTABLISH THE
<br />LOCATIONS NEEDED FOR INSTALLATION OF OTHER'S ITEMS AS REQUIRED.
<br />• CONTRACTOR IS TO LAYOUT AND PLACE ALL EMBEDS AND ANCHOR BOLTS IN
<br />CONCRETE AS SHOWN BY DRAWINGS.
<br />• CONTRACTOR TO FURNISH AND PUT TO GRADE ALL MATERIALS NEEDED TO BRING
<br />SUB GRADE TO FINAL GRADE ONCE SUB GRADE HAS BEEN BROUGHT TO PLUS
<br />(+) OR MINUS (-) A TENTH OF A FOOT.
<br />• ANY MATERIALS EXCAVATED BY CONTRACTOR ARE TO BE MOVED TO AN AREA
<br />DESIGNATED BY SUPERINTENDENT TO BE USED FOR BACK FILL LATER. (ALL
<br />SPOILS TO BE REMOVED FROM JOBSITE BY CONTRACTOR)
<br />• CONTRACTOR TO EXCAVATE DIRT BETWEEN PIERS FOR PANELS THEN BACKFILL
<br />AND COMPACT ALL AREAS NEXT TO ANY AND ALL WALLS.
<br />• CONTRACTOR TO FURNISH AND INSTALL ALL SHIMS AND REBAR PINS TO ENSURE
<br />LINE AND GRADE OF PANELS.
<br />• CONTRACTOR TO MARK PANEL LOCATIONS AND TO HAVE A PERSON PRESENT
<br />WHEN PANELS ARE BEING SET TO SURVEY IN PANELS TO ENSURE THEY ARE SET
<br />TRUE TO LINE AND GRADE.
<br />• CONTRACTOR WILL BE RESPONSIBLE FOR ENGINEERING OF LIFTING POINTS AND
<br />BRACING OF PANELS.
<br />• CONTRACTOR WILL FURNISH AND INSTALL ALL EMBEDS FOR LIFTING AND
<br />BRACING.
<br />• CONTRACTOR WILL CLEAN ALL EMBEDS AND REMOVE ANY INSPECTED BY
<br />ERECTOR PRIOR TO LIFTING OF ANY PANELS TO INSURE THEY ARE PROPERLY
<br />CLEANED AND NO DAMAGE HAS ACCRUED TO LIFTING AND BRACING EMBEDS.
<br />• CONTRACTOR TO SET NUTS ON ANCHOR BOLTS TO GRADE READY FOR
<br />PLACEMENTS OF COLUMNS.
<br />• CONTRACTOR WILL BE RESPONSIBLE FOR ANY CHARGES INCURRED DUE TO
<br />ANCHOR BOLTS OR EMBED BEING OFF FROM WHERE SHOWN ON DRAWINGS.
<br />• WHEN PANELS ARE SET AND STEEL ERECTED CONTRACTOR TO FURNISH AND
<br />POUR CONCRETE ON BOTH SIDES OF PANEL JOINTS TO SECURE THEM. THIS IS
<br />TO BE DONE BEFORE ANY BRACING IS REMOVED.
<br />ITEMS TO INCLUDE IN YOUR BID
<br />• CONTRACTOR TO FURNISH AND INSTALL ANY BLOCK OUTS FOR PLUMBING,
<br />ELECTRICAL OR ANCHOR BOLTS. THESE ARE TO BE SET AT GRADE NOT TO
<br />EXCEED 1" BELOW FINISH FLOOR AND FILLED WITH SAND TO TOP OF FORM.
<br />CONCRETE TO BE POURED OVER THESE. ONCE PANELS ARE LIFTED THESE ARE
<br />TO BE CLEANED OUT SO ANY OTHER WORK CAN BE DONE AND THEN FILLED
<br />BACK WITH CONCRETE ONCE FINISHED.
<br />• CONTRACTOR TO FURNISH AND INSTALL NON -SHRINK GROUT UNDER ALL
<br />COLUMNS.
<br />• ANY JOINTS WHERE POURS MEET ON FLOOR MUST BE A FLAT SURFACE AND
<br />ANY RAISED AREAS WILL BE GROUND BACK FLAT BY CONTRACTOR.
<br />• CONTRACTOR WILL FILL ALL PENETRATIONS MADE IN FLOOR. -ALL EMBEDS FOR
<br />LIFTING OR BRACING THAT WILL BE EXPOSED ABOVE DECK OR IN STAGING AREA
<br />WILL BE FILLED IN TO MAKE A SMOOTH SURFACE.
<br />• PANEL EDGES ON THE EXTERIOR WHERE TWO PANELS MEET WILL HAVE A
<br />CHAMFERED EDGE. HOBBY LOBBY WILL FURNISH DETAIL.
<br />• ANY IMPERFECTIONS IN PANELS THAT ARE EXPOSED TO OUTSIDE OF BUILDING
<br />WILL EITHER BE RUBBED OR FILLED SO THAT THEY WILL NOT. SHOW AFTER
<br />PAINTED AND/OR TEX-COATED.
<br />• CONTRACTOR TO SAW CUT ALL CONCRETE AS LAID OUT ON PLANS. THIS IS TO
<br />BE DONE AS SOON AS IT CAN BE DONE WITHOUT CAUSING ANY DAMAGE TO
<br />CONCRETE. NOT TO EXCEED 8 HOURS AFTER FINISHING. ANY DUSTS FROM
<br />SAWING TO BE SWEPT OFF OF SLAB TO ENSURE CLEAN SURFACE FOR PANELS.
<br />• SAW JOINTS WHERE PANELS ARE TO BE POURED ON TOP OF SLAB ARE TO BE
<br />FILLED WITH PATCHING CEMENT SO NOT TO TRANSFER TO PANELS AS A DEFECT
<br />OR LINE.
<br />• CONTRACTOR TO SAW CUT PANELS AT 18" ABOVE DECK BEARING ELEVATION
<br />FOR TERMINATION BAR OF ROOFING (WHEN APPLICABLE). THIS IS TO BE DONE
<br />BEFORE LIFTING OF PANELS.
<br />• CONTRACTOR TO CAULK A LINE ON PANELS BEFORE LIFTING AT DECK BEARING
<br />ELEVATION TO CHECK THAT ALL EMBEDS ARE AT PROPER HEIGHTS. THIS IS TO
<br />KEEP FROM HAVING ANY DELAYS DURING ERECTION OF BUILDING.
<br />• ALL CURBS ARE TO BE POURED AS EITHER A CURB AND GUTTER, OR
<br />MONOLITHIC WITH PARKING. CURBS MUST BE FORMED TO ENSURE A UNIFORM
<br />SHAPE.
<br />• CONTRACTOR TO FURNISH HOBBY LOBBY WITH A SCHEDULE OF WORK TO
<br />ENSURE IT MEETS OUR FAST TRACK SCHEDULE AND FOR THE SCHEDULING OF
<br />OTHER TRADES.
<br />• LOADING DOCK WALLS AND LIGHT POLE BASES WILL BE HAND RUBBED TO A
<br />TEXTURE FINISH AS TO NOT SHOW ANY DEFECTS.
<br />• CONTRACTOR IS RESPONSIBLE FOR ANY PRICE INCREASE OR OTHER CHARGES
<br />INCURRED TO MAINTAIN THE SCHEDULE OF THIS PROJECT. THESE CHARGES WILL
<br />NOT BE PASSED ON TO HOBBY LOBBY.
<br />• CONTRACTOR WILL BE RESPONSIBLE FOR PUMPING OF WATER THAT MIGHT BE
<br />TRAPPED IN BLOCK OUTS FOR COLUMNS, LOADING DOCK OR STORM DRAINS
<br />UNTIL THEY HAVE COMPLETED THEIR WORK IN THOSE AREAS.
<br />• CONTRACTOR IS TO PAY FOR ALL DRILLING OF PIERS, PUMPING OF CONCRETE,
<br />OR THAT OF ANY OTHER EQUIPMENT USED TO COMPLETE THEIR CONTRACT.
<br />• CONTRACTOR TO INSTALL ALL ANCHOR BOLTS FOR LIGHT POLES. OTHERS WILL
<br />SUPPLY BOLTS AND LOCATION.
<br />• ALL FINISHES AND TOLERANCES ARE TO BE AS SPELLED OUT IN SPEC. BOOK.
<br />• CONTRACTOR TO SUPPLY AND APPLY A RELEASING COMPOUND WHERE PANELS
<br />ARE POURED ON SLAB. THIS IS TO BE APPLIED HEAVY ENOUGH TO ENSURE
<br />THAT PANELS WILL NOT STICK. IF COST IS INCURRED DUE TO STICKING OF
<br />PANELS, IT WILL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PAY FOR THIS
<br />AT NO ADDITIONAL COST TO HOBBY LOBBY. ANY DAMAGE TO CONCRETE DUE TO
<br />THE STICKING PANELS WILL BE REPLACED OR REPAIRED BY CONTRACTOR.
<br />• CONTRACTOR WILL BE RESPONSIBLE FOR ANY BARRICADES TO PREVENT TRAFFIC
<br />FROM DRIVING ON PARKING UNTIL IT HAS CURED TO A POINT TO RECEIVE
<br />TRAFFIC.
<br />• CONTRACTOR TO INSTALL ALL G.C. SUPPLIED EMBEDS.
<br />• CONTRACTOR TO INSTALL ALL G.C. SUPPLIED PIPE BOLLARDS.
<br />• CONTRACTOR TO BLOCK OUT ALL OPENINGS IN PANELS ON PANEL BOOKS.
<br />THESE ARE TO BE SECURED TO MAKE SURE THEY ARE SQUARE.
<br />H.V.A.C.
<br />ITEMS TO INCLUDE IN YOUR BID IF NOT ALREADY NOTED ON PLANS:
<br />• CONTRACTOR AWARDED CONTRACT TO INSTALL NEW LENNOX R.T.U. EQUIPMENT
<br />SHALL COMPLY WITH LENNOX, HOBBY LOBBY, AND NATIONAL/LOCAL CODE
<br />INSTALLATION CRITERIA.
<br />• ANY EXISTING HEATING AND COOLING EQUIPMENT BEING USED ON THE BUILDING
<br />IS TO BE INSPECTED USING THE HOBBY LOBBY CHECKLIST SHEET AT THE START
<br />OF THE CONSTRUCTION PROJECT (WITHIN 2 WEEKS) AND A DETAILED LIST OF
<br />REPAIRS ALONG WITH AN ESTIMATE SENT TO HOBBY LOBBY FOR EVALUATION BY
<br />THE H.V.A.C. MANAGER. UPON NOTIFICATION OF BID ACCEPTANCE, CONTRACTOR
<br />HAS 2 WEEKS TO INSPECT ALL EXISTING H.V.A.C. EQUIPMENT, NOT BEING
<br />REPLACED, AND SUBMIT AN EVALUATION REPORT AND BID FOR REPAIRS TO G.C.
<br />EVALUATION MUST BE RECORDED IN FULL ON A HOBBY LOBBY EQUIPMENT
<br />EVALUATION FORM. FAILURE TO DO SO MAY AFFECT RETAINAGE IF ANOTHER
<br />CONTRACTOR MUST BE CALLED IN TO PERFORM THIS TASK. EVALUATIONS NEED
<br />ONLY TO BE COMPLETED ON EQUIPMENT NOT TO BE REPLACED.
<br />• MECHANICAL CONTRACTOR IS RESPONSIBLE FOR ASSEMBLY, SPOTTING, INTERNAL
<br />INSULATION, AND LEVELING OF ROOF CURBS. INSULATION MATERIAL USED FOR
<br />THE INTERIOR SPACE OF THE R.T.U. CURBS WILL BE THE MECHANICAL
<br />CONTRACTOR'S RESPONSIBILITY TO FURNISH AND INSTALL.
<br />• CUT DECKING AT CURBS FOR DUCT WORK INSTALLATION AND ON NEW R.T.U.
<br />UNITS HVAC CONTRACTOR SHALL INCLUDE SPACE FOR INSTALLATION OF 1"
<br />CONDUIT BY ELECTRICAL CONTRACTOR FOR CABLING REQUIREMENTS. (SEE
<br />ELECTRICAL SCOPE OF WORK)
<br />• MECHANICAL CONTRACTOR WILL BE RESPONSIBLE FOR COORDINATION OF R.T.U.
<br />DELIVERY TO JOBSITE WITH JOB SUPERINTENDENT AND LENNOX. EQUIPMENT
<br />SHOULD BE TRANSFERRED BY CRANE FROM THE DELIVERY TRUCK TO THE R.T.U.
<br />CURB AND NOT STORED ON THE GROUND.
<br />• SET ROOF TOP UNITS.
<br />• SMOKE DETECTORS ON ALL EXISTING R.T.U.S (NOT GROUND UP CONSTRUCTION)
<br />SHALL BE REPLACED BY THE MECHANICAL CONTRACTOR AND MEET LOCAL
<br />SMOKE DETECTOR FIRE CODES. SMOKE DETECTORS TO BE FURNISHED BY HOBBY
<br />LOBBY AND INSTALLED BY MECHANICAL CONTRACTOR UNLESS NOTED OTHERWISE.
<br />• INSTALL THERMOSTATS AND / OR AUTOMATION SENSORS. TERMINATE WIRING TO
<br />REQUIRED UNITS AND THERMOSTATS.
<br />• LENNOX UNITS WITH BELT DRIVE BLOWER MOTORS ARE SHIPPED WITH THE DRIVE
<br />PULLEY IN THE OPEN POSITION. CONTRACTOR MUST ALIGN AND ADJUST PULLEY
<br />TO WITHIN 1 TURN OF THE CLOSED POSITION AND THOROUGHLY TIGHTEN THE
<br />SETSCREW LOCKING THE ADJUSTMENT IN PLACE. FAILURE TO ADJUST WILL CAUSE
<br />THE UNIT TO CYCLE ON LOW PRESSURE DUE TO LOW AIR MOVEMENT. ONLY
<br />EXCEPTION, IF CERTIFIED AIR BALANCE IS PERFORMED AND PULLEY HAS BEEN
<br />SET BY THE CERTIFIED BALANCING PROCEDURE TO A DIFFERENT POSITION.
<br />• G.C. WILL WIRE UNITS TO THE BUILDING AUTOMATION SYSTEM. CHECK FOR
<br />REQUIREMENT BY SUBCONTRACTOR. (REFER TO DRAWINGS)
<br />• JOBS WITH UNUSED OR DEMISED DUCTING INN THE CEILING CAVITY SHALL HAVE
<br />SAID DUCT REMOVED BY THE MECHANICAL CONTRACTOR UNLESS STATED
<br />OTHERWISE.
<br />• FURNISH AND INSTALL ALL NECESSARY DUCTWORK PER DESIGN ENGINEER
<br />SPECIFICATIONS USING HARD ROUND OR RECTANGLE DUCT (A MAXIMUM OF 6
<br />FOOT OF FLEX MAY BE USED PER RUN BETWEEN DIFFUSER AND METAL PIPE) OR
<br />PER CODE. BALANCING DAMPERS ARE TO BE INSTALLED IN EACH SUPPLY DUCT
<br />RUN FOR BALANCING PURPOSES. DAMPERS TO BE INSTALLED AT THE END OF
<br />THE HARD PIPE DUCT RUN AND BEFORE THE FLEX DUCT CONNECTION TO THE
<br />DIFFUSER. METAL ELBOWS SHALL BE USED IN A WAY TO KEEP FLEXIBLE DUCT
<br />CONNECTIONS STRAIGHT BETWEEN ROUND METAL SUPPLY DUCTING AND THE
<br />SUPPLY GRILLE. NO ELLS ARE TO BE FORMED WITH FLEXIBLE DUCTING.
<br />• FURNISH AND INSTALL ALL DIFFUSERS. BALANCE AIRFLOW TO EACH REGISTER.
<br />• RECOVER ALL REFRIGERANT IN ABANDONED UNITS. (CONTRACTOR TO SUPPLY
<br />REFRIGERANT INCIDENT REPORT TO HOBBY LOBBY VERIFYING EQUIPMENT
<br />DISPOSAL.)
<br />• UNITS 7.5 TON AND LARGER WITH CONCENTRIC AIRFLOW DESIGN SHALL USE
<br />RECTANGLE METAL CONNECTIONS PER THE M-2 DRAWINGS. ABSOLUTELY NO
<br />FLEXIBLE ROUND DUCT OR RIGID ROUND DUCT CONNECTIONS IN ANY
<br />CONFIGURATION WILL BE ACCEPTED BETWEEN THE UNIT AND CONCENTRIC
<br />PACKAGES.
<br />• MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR SPOTTING AND
<br />COORDINATING INSTALLATION OF EXHAUST FAN CURB/S WITH THE ROOFING
<br />CONTRACTOR.
<br />• CONTRACTOR SHALL COMPLETE HOBBY LOBBY NEW EQUIPMENT START UP CHECK
<br />LIST WHEN INSTALLATION IS COMPLETE. THE COMPLETED FORM, FOR EACH UNIT,
<br />IS TO BE GIVEN TO THE HOBBY LOBBY SUPERINTENDENT WITH ALL INFORMATION
<br />RECORDED FOR REVIEW.
<br />• CONTRACTOR TO MAINTAIN A CLEAN WORK ENVIRONMENT AND REMOVE TRASH
<br />AND DEBRIS FROM WORK AREA DAILY. ANY CHARGES FOR ROOF REPAIR OR
<br />CLEAN UP CREATED DUE TO NEGLIGENCE WILL BE WITHHELD FROM
<br />CONTRACTORS' RETAINAGE, NO EXCEPTIONS.
<br />• NUMBERING OF H.V.A.C. EQUIPMENT TO MATCH HOBBY LOBBY DRAWING AND
<br />PERFORMED BY H.V.A.C. CONTRACTOR PER SHEET BAS1.
<br />• MECHANICAL CONTRACTOR WILL COORDINATE WITH ROOFER THE PLACEMENT OF
<br />CURBS AND CUTTING OF THE DECKING MATERIAL.
<br />• STORES WITH OPEN CEILINGS AND CONCENTRIC AIR DISTRIBUTION DESIGN WILL
<br />HAVE CONCENTRIC SUPPLIES INSTALLED IN A MANNER TO PREVENT SUPPLY AIR
<br />FROM DISCHARGING DIRECTLY ON LIGHT FIXTURES. THE TOP OF THE SUPPLY
<br />DISCHARGE OPENING SHOULD BE MOUNTED NO HIGHER THAN THE BOTTOM OF
<br />ALL LIGHTING FIXTURES.
<br />• INSTALL DUCTWORK IN OPEN CEILING BEFORE PAINT AND INSTALL DUCTWORK IN
<br />GRID CEILING BEFORE GRID INSTALLATION.
<br />• MECHANICAL CONTRACTOR WILL BE RESPONSIBLE TO PERFORM TWO FILTER
<br />CHANGES IN ALL R.T.U. UNITS OPERATED DURING CONSTRUCTION, USING PLEATED
<br />FILTERS WITH A RATING OF NO LESS THAN A MERV 7. FIRST CHANGE TO BE
<br />PERFORMED AT THE HEIGHT OF CONSTRUCTION DEMO WITH THE SECOND AFTER
<br />FIXTURING BEFORE STORE OPENING.
<br />UNLESS SPECIFIED ELSEWHERE,MECHANICAL
<br />E CHANI CAL CONTRACTOR SHALL BE
<br />RESPONSIBLE FOR CONDENSATE DRAINS MEETING LOCAL AND NATIONAL CODES.
<br />SUPPORTS SHALL BE OF TYPE IDENTIFIED ON M-2 DRAWINGS AND ATTACHED TO
<br />ROOF MEMBRANE IN A MANNER NOT TO AFFECT ROOF WARRANTY AND TO
<br />PREVENT PIPING FROM MOVING OR SAGGING.
<br />• LAY IN SUPPLY DIFFUSERS SHALL BE INSTALLED WITH AN INSULATED METAL
<br />ELBOW CONNECTING FROM THE FLEXIBLE DUCT DROP TO THE MATCHING THROAT
<br />SIZE OF THE DIFFUSER. DIFFUSER BACKING SURFACE SHALL ALSO BE OF THE
<br />INSULATED VARIETY OR INSULATED BY THE MECHANICAL CONTRACTOR.
<br />• EQUIPMENT TO BE REPLACED OR REMOVED FROM STRUCTURE SHALL BE
<br />DISPOSED OF IN ACCORDANCE WITH APPROPRIATE EPA GUIDELINES. PROPER
<br />DOCUMENTATION WILL BE FURNISHED TO HOBBY LOBBY DESCRIBING MEANS OF
<br />RECOVERY AND DISPOSAL
<br />• MECHANICAL CONTRACTOR WILL BE RESPONSIBLE FOR INSTALLATION OF FILTER
<br />MEDIA, FURNISHED BY HOBBY LOBBY, TO ALL RETURN GRILLES OR UNFINISHED
<br />RETURN DUCT OPENINGS OF R.T.U.'S OPERATED DURING CONSTRUCTION. NO UNIT
<br />SHALL BE RUN DURING CONSTRUCTION WITHOUT THIS PRECAUTION BEING
<br />ADHERED TO.
<br />• MECHANICAL CONTRACTOR WILL COORDINATE WITH JOB SUPERINTENDENT THE
<br />ISOLATION AND PROTECTION OF RETURN AIR SMOKE DETECTOR SAMPLING TUBES
<br />AND SENSING CHAMBER IMMEDIATELY AFTER PLACEMENT OF EQUIPMENT ON THE
<br />ROOF, BEFORE STARTUP. CONTRACTOR WILL BE HELD LIABLE FOR SMOKE
<br />DETECTOR FAILURE IF THIS PROCEDURE IS NOT FOLLOWED - NO EXCEPTIONS.
<br />PROCEDURE TO BE REVERSED BY THE MECHANICAL CONTRACTOR BEFORE
<br />COMMISSIONING OF FIRE ALARM AND TESTING
<br />L ES G OF SMOKE DETECTORS.
<br />• AS-BUILTS ARE TO BE COMPLETED AND TURNED INTO THE HOBBY LOBBY
<br />SUPERINTENDENT AT COMPLETION OF JOB.
<br />• HVAC CONTRACTOR SHALL WIRE A THERMOSTAT FOR ALL EXISTING AND NEW
<br />UNIT HEATERS.
<br />ELECTRICAL
<br />ITEMS TO INCLUDE IN YOUR BID IF NOT ALREADY NOTED ON PLANS:
<br />• DEMO ALL UNUSED PANELS.
<br />• DEMO ALL POWER COMING UP THRU FLOOR.
<br />• DISCONNECT (SAFE OFF) ALL ELECTRICAL IN WALLS AND LIGHTING TO BE
<br />REMOVED.
<br />• RELOCATE ANY PANELS POSSIBLE NEEDED TO ACCOMMODATE NEW CIRCUITS.
<br />WIRE AND INSTALL ALL OWNER PROVIDEDPOWER
<br />OWER POLES PER PLANS.
<br />• WIRE AND INSTALL ALL OWNER PROVIDED PLUG MOLD PER PLANS.
<br />• WIRE AND INSTALL ALL 3 PHASE 208 OR 480 CIRCUITS TO ROOF TOP UNITS.
<br />(DISCONNECT PROVIDED IN ALL NEW ROOF TOP UNITS.) CONTRACTOR TO PROVIDE
<br />EXTERNAL DISCONNECT IF REQUIRED BY CODE.
<br />• PROVIDE WIRE TO AND INSTALL WEATHER PROOF G.F.I. CIRCUITS PER LOCAL
<br />CODE ON R.T.U.'S.
<br />• A 1" CONDUIT IS TO BE INSTALLED ON ALL EXISTING AND NEW R.T.U'S FOR THE
<br />PURPOSE OF ROUTING ALL COMMUNICATION AND LOW VOLTAGE WIRING. CONDUIT
<br />SHALL CONNECT FORM INSIDE THE ELECTRICAL COMPARTMENT OF R.T.U.
<br />PENETRATING THE ROOF DECK AND TO EXTEND NO LESS THAN 18" BELOW THE
<br />ROOF DECK. CONDUIT ENDS SHALL HAVE A CONNECTOR AND BUSHING ON EACH
<br />END.
<br />• PROVIDE ALL CONDUIT STUBS FOR PHONE, DATA, T.V., CAMERAS, ALARMS OR
<br />OTHER DEVICES PER PLANS.
<br />• PROVIDE WIRE TO AND INSTALL BUZZER SYSTEM TO TRUCK DOCK ENTRANCE PER
<br />PLANS.
<br />• PROVIDE WIRE TO AND INSTALL BUZZER SYSTEM FOR STORE EMPLOYEE
<br />ENTRANCE PER PLANS.
<br />• WIRE CIRCUIT TO BALER PER PLANS AND FURNISH DISCONNECT.
<br />• WIRE CIRCUIT TO COMPACTOR PER PLANS AND FURNISH DISCONNECT.
<br />• WIRE (3) 120 VOLT 20 AMP CIRCUITS TO SIGNAGE PER PLANS WITH JUNCTION
<br />BOXES.
<br />• PROVIDE WIRE TO INSTALL (1) 120 VOLT 20 AMP DEDICATED CIRCUIT FOR
<br />SECURITY SYSTEM.
<br />• PROVIDE WIRE TO INSTALL (1) 120 VOLT 20 AMP DEDICATED CIRCUIT FOR FIRE
<br />ALARM SYSTEM.
<br />• WIRE AND INSTALL ALL OWNER PROVIDED LIGHT FIXTURES PER PRINT.
<br />• SUPPLY UNI-STRUT AND FIXTURE CHAIN ON LIGHT FIXTURES IN SALES AREA.
<br />(OPEN CEILING SYSTEMS ONLY) ALL LIGHTING TO BE LEVEL AND STRAIGHT.
<br />• PROVIDE AND INSTALL (2) 3" CONDUITS FROM TELEPHONE BOARD TO DECK FOR
<br />HOBBY LOBBY INSTALLED LOW VOLTAGE WIRING.
<br />• ELECTRICAL CONTRACTOR SHALL INSTALL OWNER PROVIDED LIGHTING CONTACTOR
<br />PANEL (L.C.O.). ALL BUILDING AUTOMATION SYSTEM INTERIOR AND EXTERIOR
<br />LIGHTING, POWER POLES, AND CEILING PLUGS ARE TO BE CONNECTED IN THE
<br />.C.P. THEN ROUTED BACK TO APPROPRIATE BREAKER PANEL.
<br />• ELECTRICAL CONTRACTOR SHALL PROVIDE 120 VAC POWER TO L.C.P. ALSO
<br />PROVIDE PVC RACEWAY TO EXTEND FROM THE TOP LEFT OF THE L.C.P. UP
<br />THROUGH THE DROP CEILING OR CEILING GIRDER WHICH EVER IS REQUIRED.
<br />• INVESTIGATE M.D.P. FOR LIGHTING CONTROL CIRCUITS FOR EXTERIOR LIGHTING
<br />CIRCUITS, DESIGNATE, AND MARK.
<br />• INVESTIGATE TO ASSURE NO OTHER BUILDINGS OR AREAS ARE BEING SUPPLIED
<br />FROM HOBBY LOBBY ELECTRICAL SWITCH.
<br />• TEMPORARY LIGHTING AS NEEDED FOR CONSTRUCTION PURPOSES.
<br />• IDENTIFY AND MARK ALL SERVICE GEAR AND PANELS WITH TYPED PRINT.
<br />• RENTAL EQUIPMENT
<br />• ELECTRICAL PERMIT
<br />• ALL DEMO WIRING AND PANELS ARE THE PROPERTY OF HOBBY LOBBY.
<br />• IDENTIFY ELECTRIC SERVICE AND METER SUPPLYING POWER TO LOCATION.
<br />• CONFIRM NO CIRCUITS FEED POWER TO ADJACENT SPACE OR EXTERIOR OF
<br />BUILDING FROM DISTRIBUTION PANELS, I.E. PARKING LOT LIGHTING, PEDESTAL
<br />SIGNS, ETC.
<br />• IDENTIFY ANY SUB -METERS ON UTILITY SERVICE AND THEIR PURPOSE
<br />• REQUEST THE MOST CURRENT FIXTURE PLAN FROM SUPERINTENDENT BEFORE
<br />INSTALLING THE HOME RUNS TO THE POWER POLES AND ANY FIXTURE DISPLAY.
<br />• ALL SENSOR, COMMUNICATION, (SECURITY AND FIRE AS NEEDED) CABLES SHALL
<br />BE PULLED THROUGH 1" CONDUIT INTO R.T.U. CABLES ARE NOT TO BE
<br />STRETCHED, NICKED, OR CUT. CABLES IS TO BE ROLLED UP AND TAPED INSIDE
<br />OF UNIT.
<br />• ALARM DRAWINGS PROVIDED BY HOBBY LOBBY. PROVIDE CONDUIT AND J-BOXES
<br />WHERE REQUIRED FOR CEILING HORNS, PULL STATIONS, CONTROL PANEL AND
<br />KEY PAD. IF ALARM PLAN IS UNAVAILABLE OR NOT ATTACHED TO THE SET OF
<br />PLANS AT THE TIME OF BIDDING ONE WILL BE PROVIDED TO ELECTRICAL
<br />CONTRACTOR.
<br />• WIRE EXHAUST FAN FOR RESTROOMS AND CONFIRM VOLTAGE WITH H.V.A.C.
<br />CONTRACTOR.
<br />• WIRE WATER HEATER FOR RESTROOMS AND CONFIRM VOLTAGE WITH PLUMBING
<br />CONTRACTOR.
<br />• PROVIDE AND INSTALL (1) 3" CONDUIT FROM ALARM PANEL TO BOTTOM OF BAR
<br />JOISTS. VERIFY LOCATION ON PLANS.
<br />• PROVIDE TEMPORARY 200 AMP PANEL LOCATED IN THE CENTER OF THE STORE
<br />WITH 20 CIRCUITS FOR CONTRACTOR USE.
<br />• PROVIDE A SEPARATE PRICE FOR EXTERNAL DISCONNECT WHICH MAY BE
<br />REQUIRED BY CODE.
<br />• NUMBERING OF R.T.U.'S ARE TO FOLLOW BUILDING AUTOMATION SYSTEM DRAWING.
<br />• AS-BUILTS ARE TO BE COMPLETED AND TURNED INTO THE HOBBY LOBBY
<br />SUPERINTENDENT AT COMPLETION OF JOB.
<br />• 10 TON LENNOX R.T.U. DISCONNECTS SHALL BE LOCATED AS INDICATED (SEE
<br />DETAIL SHEET 5-E3).
<br />• TWO (22) FOUR SQUARE BOXES (ONE ABOVE THE OTHER CONNECTED BY ["
<br />CONDUIT) WITH S/G PLASTER RING (5/8" RAISE) SHALL BE MOUNTED ON
<br />COLUMNS WITH THERMOSTATS. TWO [" CONDUITS OUT OF THE TOP OF THE BOX
<br />SHALL BE EXTENDED 6 INCHES ABOVE CEILING GRID. CONDUIT END SHALL HAVE
<br />A CONNECTOR AND BUSHING ON EACH END.
<br />• A (2-") FOUR SQUARE BOX WITH S/G PLASTER RING (NO RAISE) SHALL BE
<br />MOUNTED FOR UNIT HEATER SENSORS PER E1 OR BUILDING AUTOMATION SYSTEM
<br />DRAWINGS. A [" CONDUIT OUT OF THE TOP OF THE BOX IS TO BE EXTENDED NO
<br />LESS THAN 1 FOOT FROM THE DECK. CONDUIT END SHALL HAVE A CONNECTOR
<br />AND BUSHING ON EACH END.
<br />• ALL BREAKERS ARE TO BE LABELED.
<br />• ELECTRICAL CONTRACTOR SHALL INSTALL OWNER PROVIDED VERIS METER AT
<br />SERVICE ENTRANCE FEEDING MAIN DISTRIBUTION PANEL. THE VERIS METER IS TO
<br />BE POWERED WITH A 3-PHASE 20 AMP BREAKER.
<br />• PROVIDE ADD ALTERNATE TO FURNISH AND INSTALL CEILING WIRE AT ALL LIGHT
<br />FIXTURE CEILING BRACKETS.
<br />SPRINKLER
<br />ITEMS TO INCLUDE IN YOUR BID IF NOT ALREADY NOTED ON PLANS:
<br />• PRIOR TO STARTING WORK CONTRACTOR SHALL SEND TWO COPIES OF PLANS TO
<br />CORPORATE OFFICE FOR OUR REVIEW AND RECORDS. SEND TO CONSTRUCTION
<br />DEPARTMENT CONTRACTOR ADMINISTRATOR: 7707 S.W. 44TH STREET, OKLAHOMA
<br />CITY, OKLAHOMA 73179.
<br />• PROVIDE AND INSTALL VALVED TEST CONNECTIONS FOR SYSTEM AS REQUIRED.
<br />• NECESSARY ENAMEL SIGNS SHALL BE INSTALLED ON CONTROL VALVES, DRAINS, AND
<br />INSPECTOR'S TEST IN ACCORDANCE WITH GOVERNING BODIES SPECIFICATIONS.
<br />• CONTRACTOR IS RESPONSIBLE FOR INSTALLING FIRE SUPPRESSION SYSTEM PER
<br />GOVERNING AGENCY.
<br />• CONTRACTOR RESPONSIBLE FOR ALL PERMITS, LICENSE AND OBTAINING
<br />APPROVED DRAWINGS FOR GOVERNING AGENCY.
<br />• CONTRACTOR TO DESIGN LOCATION OF SPRINKLER HEADS TO AVOID CONFLICT
<br />WITH LAYOUT OF LIGHT FIXTURES AND CEILING GRID. LIGHT FIXTURE LAYOUT WILL
<br />STAY AS DESIGNED AND NOT BE MOVED. SPRINKLER HEADS WILL BE ADJUSTED
<br />ACCORDINGLY AROUND FIXTURE LAYOUT.
<br />• CONTRACTOR IS RESPONSIBLE FOR STANDARD PIPE CONNECTION, CONNECTION TO
<br />THE BUILDING, AND BRINGING MAIN INTO BUILDING AT SPECIFIED STUB UP.
<br />OWNER PROVIDES WATER MAIN LOCATED 5' OUTSIDE OF BUILDING LINE.
<br />CONTRACTOR IS RESPONSIBLE FOR EXCAVATION AND BACKFILL.
<br />• CONTRACTOR TO PROVIDE BACK FLOW PREVENTER IF REQUIRED BY NATIONAL
<br />CODE OR CITY REQUIREMENTS.
<br />• CONTRACTOR IS RESPONSIBLE FOR ALL TESTS TO MEET GOVERNING CODES.
<br />• CONTRACTOR TO PROVIDE ALL TAMPER AND FLOW VALVES NECESSARY FOR
<br />SYSTEMS.
<br />• CONTRACTOR WILL BE REQUIRED TO BE AVAILABLE AT THE JOB SITE FOR ALL
<br />SPRINKLER AND ALARM RELATED INSPECTIONS. RE -INSPECTIONS ARE INCLUDED
<br />ALSO.
<br />• P.I.V., F.D.C. AND ASSOCIATED BACK FLOWS PROVIDED IF REQUIRED.
<br />• CONTRACTOR TO FURNISH AND INSTALL BOX FOR SPARE HEADS AND WRENCHES.
<br />• ALL AREAS WITH A GRID CEILING AND SURFACE MOUNTED LIGHTS SHALL HAVE A
<br />PENDANT TYPE SPRINKLER HEAD WITH A 2 PIECE ESCUTCHEON THAT HANGS
<br />DOWN BELOW THE CEILING SO THAT LIGHTS WILL NOT INTERFERE WITH THE
<br />COVERAGE. ALL LAYOUT OF SPRINKLERS MUST MATCH HOBBY LOBBY LIGHTING
<br />LAYOUT.
<br />• ALL SPRINKLERS SHALL BE COORDINATED TO MISS THE CEILING GRID.
<br />• SPRINKLERS SHALL BE SPACED IN ACCORDANCE WITH THE LIGHTING AND
<br />MECHANICAL EQUIPMENT. LIGHTING AND MECHANICAL EQUIPMENT PLACEMENT
<br />SHALL HAVE PRIORITY OVER THE SPRINKLER PIPING. SPRINKLER PIPES SHALL
<br />NOT PENETRATE AIR DUCTS OR STRUCTURAL MEMBERS. PROVIDE ADDITIONAL
<br />SPRINKLERS AROUND MECHANICAL EQUIPMENT, PIPING, DUCTWORK AND OTHER
<br />OBSTRUCTIONS AS REQUIRED BY NFPA 13.
<br />• PROVIDE CEILING ACCESS DOORS WHERE REQUIRED TO ACCESS VALVES OR
<br />OTHER ITEMS REQUIRING MAINTENANCE IN PLASTER CEILINGS. ALL ACCESS
<br />DOORS SHALL BE SIZED AND LOCATED TO PERMIT EASY ACCESS TO THE ITEMS
<br />REQUIRING MAINTENANCE. CEILING ACCESS DOORS SHALL BE 24" x 24"
<br />MINIMUM.
<br />• ALL PIPING SHALL BE CONCEALED ABOVE CEILING OR IN WALL SPACES UNLESS
<br />OTHERWISE NOTED. THE ROUTING OF ALL EXPOSED PIPING SHALL BE REVIEWED
<br />AND APPROVED IN THE FIELD BY HOBBY LOBBY PRIOR TO INSTALLATION.
<br />• ALL EXPOSED SPRINKLER PIPING DOES NOT NEED TO BE PAINTED UNLESS
<br />REQUIRED BY LOCAL CODE. IF SPRINKLER PIPE PAINTING IS REQUIRED ALL
<br />PIPING SHALL BE THOROUGHLY CLEANED BEFORE IT IS PAINTED. INSTALL
<br />CHROME ESCUTCHEONS AT ALL EXPOSED WALL PENETRATIONS. SLEEVE AND
<br />SEAL WALL AND FLOOR PENETRATIONS AS SPECIFIED.
<br />• ALL WALL PENETRATIONS OF FIRE RATED ASSEMBLIES SHALL BE SEALED AS
<br />SPECIFIED. VERIFY LOCATION OF ALL FIRE RATED WALLS AND FLOORS WITH
<br />OWNER. SEAL ALL REVEALING WALL PENETRATIONS & CAULK. SEE
<br />SPECIFICATIONS.
<br />ALL SPRINKLER PIPING SHALL BE INSTALLED AT SUCH T T C H HE SYSTEM WILL
<br />COMPLETELY DRAIN BACK TO THE MAIN. IF A SECTION OF PIPING CANNOT BE
<br />SLOPED BACK TO THE MAIN, AN AUXILIARY DRAIN VALVE WITH PERMANENT
<br />LABEL AND HOSE THREAD CONNECTION MUST BE INSTALLED. ALL AUXILIARY
<br />DRAINS SHALL BE CONCEALED FROM OCCUPIED SPACES.
<br />• FIRE PROTECTION CONTRACTOR SHALL PERFORM FLOW TEST TO VERIFY
<br />AVAILABLE FLOW PRIOR TO PREPARING HYDRAULIC CALCULATIONS.
<br />STEEL ERECTION
<br />ITEMS TO INCLUDE IN YOUR BID IF NOT ALREADY NOTED ON PLANS:
<br />• CONTRACTOR TO SCHEDULE UNLOADING OF ALL STEEL DELIVERED TO SITE AND
<br />STAGE IN DESIGNATED AREA.
<br />• CONTRACTOR IS TO PROVIDE ALL EQUIPMENT AND LABOR NECESSARY FOR
<br />INSTALLATION OF ALL STEEL AND ANY WORK RELATED TO CONTRACT.
<br />• CONTRACTOR IS TO CONFIRM MATERIAL LIST AT TIME OF OFF LOAD. SHORTAGES
<br />SHOULD BE NOTED ON DELIVERY TICKET.
<br />• CONTRACTOR WILL BE REQUIRED TO CONFIRM PANEL LAYOUT WITH CONCRETE
<br />CONTRACTOR.
<br />• CONTRACTOR IS REQUIRED TO INSTALL ALL R.T.U. STRUCTURAL FRAMING SHOWN
<br />ON PRINTS AND COORDINATE WITH H.V.A.C. CONTRACTOR.
<br />• PANEL ERECTING IS TO BE INCLUDED ALONG WITH BRACING.
<br />• CONTRACTOR TO INCLUDE PRICE FOR RAILING AND JIB CRANE INSTALLATION.
<br />E.I.F.S.
<br />ITEMS TO INCLUDE IN YOUR BID IF NOT ALREADY NOTED ON PLANS:
<br />• CONTRACTOR IS TO PROVIDE ALL NECESSARY EQUIPMENT TO COMPLETE THE JOB.
<br />• CONTRACTOR IS REQUIRED TO KEEP PRODUCT OFF OF OTHER MATERIALS AND
<br />SURFACES.
<br />• CONTRACTOR MUST VERIFY E.I.F.S. COLORS THROUGH HOBBY LOBBY BEFORE
<br />ORDERING MATERIALS.
<br />• CONTRACTOR IS TO PROVIDE A PRICE FOR WEATHER PROTECTION IF IT BECOMES
<br />NECESSARY.
<br />• CONTRACTOR IS REQUIRED TO USE SENERGY OR DRYVIT FINISH PRODUCTS.
<br />MASONRY
<br />ITEMS TO INCLUDE IN YOUR BID IF NOT ALREADY NOTED ON PLANS:
<br />• CONTRACTOR TO PROVIDE ALL MATERIALS AND LABOR AS SPECIFIED.
<br />• CONTRACTOR IS TO PROVIDE ALL EQUIPMENT NECESSARY INCLUDING
<br />SCAFFOLDING TO COMPLETE THE JOB.
<br />• CONTRACTOR IS TO PROVIDE A COST FOR WINTERIZATION AS AN ALTERNATE.
<br />• CONTRACTOR IS TO BE RESPONSIBLE FOR STORAGE OF HIS MATERIALS AND
<br />SUPPLIES ON THE JOB SITE.
<br />• CONTRACTOR IS RESPONSIBLE FOR REMOVING WATER, SILT, SLUDGE, SAND, OR
<br />DIRT THAT HAS ACCUMULATED ON FOOTING DURING CONSTRUCTION WORK IN
<br />ORDER TO PROCEED WITH HIS OWN WORK.
<br />• CONTRACTOR IS TO PROVIDE AND INSTALL ALL STEEL LINTELS, REBAR AND DRY
<br />STACK STONES.
<br />• MASONRY CONTRACTOR IS RESPONSIBLE FOR ALL BRACING NECESSARY FOR THE
<br />WALLS.
<br />• CONTRACTOR IS TO PROVIDE AND INSTALL WEEP HOLES WHERE SHOWN ON
<br />DRAWINGS.
<br />• CONTRACTOR IS RESPONSIBLE FOR CLEANING OUT MASONRY EXPANSION JOINTS
<br />BEFORE THE WATERPROOFING OF EXPANSION JOINT WITH CAULKING.
<br />• CONTRACTOR IS RESPONSIBLE FOR REMOVAL OF EXCESS GROUT IN JOIST
<br />POCKETS.
<br />• CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF ALL EMBED PLATES AND
<br />ANCHOR BOLTS.
<br />• CONTRACTOR IS RESPONSIBLE FOR FILLING CELLS WITH GROUT PER STRUCTURAL
<br />DRAWINGS AND APPLICABLE CODES PER CITY AND STATE.
<br />• CONTRACTOR IS RESPONSIBLE FOR MATCHING COLOR OF MASONRY AND GROUT.
<br />• PROVIDE SAMPLE PANEL OF MASONRY PRODUCTS IF REQUIRED.
<br />STOREFRONT
<br />ITEMS TO INCLUDE IN YOUR BID IF NOTE ALREADY NOTED ON PLANS:
<br />• CONTRACTOR IS TO PROVIDE SILL PLATE AT BOTTOMS OF ALL MULLIONS.
<br />• CONTRACTOR IS TO PROVIDE CLOSED BACK JAMB FOR INSTALLATION OF
<br />AUTOMATIC DOORS.
<br />• VERIFY ON PRINTS, ANY TINTING REQUIREMENTS BY CODE.
<br />• WHEN USING 4 1 /2" INCH MULLIONS YOU WILL BE REQUIRED TO WET SET INSIDE
<br />OF RAILS AND STILES BEFORE SETTING GLASS.
<br />• CONTRACTOR IS TO PROVIDE ALL CAULKING AROUND PERIMETER OF GLASS
<br />STOREFRONT INSIDE AND OUT.
<br />• CONTRACTOR WILL BE REQUIRED TO INSTALL STOREFRONT BEFORE AUTOMATIC
<br />DOORS ARE INSTALLED. VERIFY FINISHED OPENING BEFORE MANUFACTURING.
<br />• VERIFY THAT ALL FRAMES AND GLAZING MEET APPLICABLE CODES.
<br />ROOFING
<br />ITEMS TO INCLUDE IN YOUR BID IF NOT ALREADY NOTED ON PLANS:
<br />• CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF WOOD NAILERS AND
<br />PLYWOOD AT THE TOP OF C.M.U., TILT UP WALL, E.I.F.S., AND STRUCTURAL
<br />FRAMING AND BID AS AN ADD ALTERNATE.
<br />• CONTRACTOR IS REQUIRED TO PROVIDE ALL NECESSARY PADS UNDER GAS LINES,
<br />CONDENSATE LINES, AND WALK PADS.
<br />• CONTRACTOR IS TO PROVIDE THE ROOF WARRANTY TO HOBBY LOBBY IN THE
<br />OWNER'S NAME AND ADDRESS. VERIFY COVERAGE REQUIRED (I.E. 15 OR 20 YEAR
<br />WARRANTY)
<br />• CONTRACTOR IS REQUIRED TO USE HICKMAN FLASHING, OR APPROVED EQUAL,
<br />WHERE DESIGNATED ON PRINTS.
<br />• CONTRACTOR IS REQUIRED TO FILL IN METAL DECKING BEFORE RE -ROOFING
<br />OVER (ON REMODELS).
<br />• CONTRACTOR IS RESPONSIBLE FOR ALL GUTTERING AND DOWNSPOUTS AS PER
<br />PLANS. PROVIDE ADAPTORS AT BOTTOM OF DOWNSPOUT TO STORM SEWER
<br />SYSTEM IF REQUIRED.
<br />• CONTRACTOR WILL BE REQUIRED TO DO A FINAL SWEEP AFTER STORE IS
<br />COMPLETED TO REPAIR DAMAGE OR FAULTY INSTALLATION. A ROOF DAMAGED BY
<br />NEGLIGENCE WILL BE BACK CHARGED TO RESPONSIBLE PARTY.
<br />• CONTRACTOR MUST PROVIDE AND INSTALL EXPANSION JOINTS, VERTICAL AND
<br />HORIZONTAL WHEN REQUIRED. THEY MUST BE INSTALLED PER DETAILS ON
<br />DRAWINGS.
<br />PAINTING
<br />ITEMS TO INCLUDE IN YOUR BID IF NOT ALREADY NOTED ON PLANS:
<br />• CONTRACTOR IS REQUIRED TO PROVIDE ALL EQUIPMENT AND MATERIALS
<br />NECESSARY TO COMPLETE JOB.
<br />• CONTRACTOR IS RESPONSIBLE FOR KEEPING ALL PAINT OFF OF FLOORS,
<br />PARAPETS, AND BAR JOISTS.
<br />• CONTRACTOR WILL BE REQUIRED TO CAULK ALL PRODUCTS FINISHED TO: F.R.P.,
<br />METAL JAMBS, CABINETS, ETC.
<br />• ALL WALLS, COLUMNS, AND PEG WILL BE REQUIRED TO HAVE ONE COAT PRIMER
<br />AND TWO COATS FINISH.
<br />• CONTRACTOR IS REQUIRED TO SUBMIT EXTERIOR PAINT SAMPLES TO BE
<br />APPROVED BY HOBBY LOBBY.
<br />• ALL PAINT MATERIALS TO BE PURCHASED FROM SHERWIN WILLIAMS. OIL BASE IS
<br />REQUIRED ON ALL METAL. SEMI -GLOSS LATEX IS REQUIRED ON ALL WALLS
<br />INCLUDING STAGING AREA WALLS. C.M.U. AND CONCRETE WALLS ARE NOT
<br />REQUIRED TO BE PAINTED IF NEW ONLY IF PREVIOUSLY PAINTED. IF PAINTED,
<br />BLOCK FILLER MUST BE INCLUDED.
<br />• CONTRACTOR NEEDS TO REPLACE CEILING TILE IF REMOVED WHILE PAINTING.
<br />• CONTRACTOR IS REQUIRED TO IDENTIFY ALL TOUCH UP PAINT WITH PERMANENT
<br />MARKER FOR STORE MANAGER. REMOVE ALL OTHER PAINT AND MATERIALS FROM
<br />JOB SITE AND DISPOSE OF AV PROPERLY. CH -UP PAINT.
<br />LEAVE TOUCH-UP
<br />• ALL SPRINKLER HEADS ARE TO BE PROTECTED FROM PAINT OVER SPRAY AND
<br />THE METHOD OF PROTECTION OR COVERING REMOVED.
<br />• PAINT ALL EXPOSED METAL ON ROOF INCLUDING ROOF HATCH AND BRACES.
<br />• PAINT ALL GAS LINES ON ROOF.
<br />• IN AN OPEN OR EXPOSED CEILING SITUATION CONTRACTOR IS TO PROTECT OR
<br />CLEAN FLOORING AND ALL AREAS NOT TO RECEIVE PAINT.
<br />ALARM SYSTEMS
<br />ITEMS TO INCLUDE IN YOUR BID IF NOT ALREADY NOTED ON PLANS:
<br />• ALARM CONTRACTOR TO BID AND INSTALL SYSTEM PER HOBBY LOBBY ALARM
<br />CONTRACTOR FIELD PACK.
<br />p+enb412
<br />hitecture
<br />gineering
<br />710 West Roselawn Drive
<br />Rogers, Arkansas 72756
<br />Phone: 479.636.3545
<br />Fax: 479.636.1209
<br />William Douglas Hurley
<br />Florida License No AR91919
<br />Firm License No: AA26000940
<br />W �� ~w wpzN
<br />(n o Lnows �N<-ao
<br />zaF zwt�w¢3
<br />W w �V)LX a5�poo<
<br />aQ E=zQN=
<br />Of a oa
<br />O Loa ¢c�a``'ac~io�o
<br />!i a CJ .z,z�� �w�F
<br />U
<br />X
<br />O 3w�W��oowawCr LU acr~oa
<br />00- z�� oa���z�
<br />Qzv)nw8o v� w� ocno
<br />aaSaz V- ZF-J�C7F-
<br />0_ 00Xww<w`o�wWZ �m
<br />�wazl-'~ow�'ooc�ao}
<br />U7 F-�ii�n(Aa.z>iraawoaM
<br />>M
<br />I
<br />M
<br />0
<br />w Q
<br />Q
<br />~ JO
<br />1Z )LL
<br />illiiiiiiiiiiiiiiiiiiiiii
<br />O 0(6
<br />m J
<br />�_ J 2
<br />Q
<br />r>_W
<br />'o
<br />Ly(D=
<br />CL=�MCO
<br />N
<br />0
<br />M
<br />(`
<br />w
<br />��
<br />as
<br />0
<br />ti
<br />ISSUE BLOCK
<br />CHECKED BY:
<br />DF
<br />DRAWN BY:
<br />JCF
<br />FILE NAME:
<br />G1.1
<br />DOCUMENT DATE:
<br />08-09-13
<br />I
<br />.0
<br />DID
<br />NOTES
<br />I I .
<br />SHEET:
<br />G1.1 1 -