My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7331 Gall Blvd (2)
Zephyrhills
>
Building Department
>
Building Plans
>
7331 Gall Blvd (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 9:14:32 PM
Creation date
2/18/2025 3:38:17 PM
Metadata
Fields
Template:
Building Plans
Street #
7331
Location
Gall Blvd
Contractor
Aspen Construction Solutions Inc
Building Plans - Permit #
4027
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FIXTURE & CONNECTION SCHEDULE <br />BRANCH SIZE <br />FIXTURE <br />TAG <br />MANUFACTURER/MODEL <br />REMARKS <br />DRAINAGE <br />WATER <br />WASTE <br />VENT <br />COLD <br />HOT <br />LAVATORY <br />LAV-1 <br />2" <br />2" <br />1/2" <br />1 /2" <br />AMERICAN STANDARD LUCERNE #0355.012 <br />LAVATORY: 20"x18", VITREOUS CHINA, WITH FAUCET LEDGE AND INTEGRAL <br />(ADA) <br />DELTA SINGLE LEVER FAUCET #523LF—HGMHDF <br />OVERFLOW. PROVIDE ARM CHAIR FLOOR CARRIER. SINGLE LEVER FAUCET <br />MIXING VALVE: LAWLER # TMM-1070 <br />WITH 4" CENTERS, 0.5—GPM AERATOR, &GRID DRAIN ASSEMBLY. PROVIDE <br />ASSE 1070 LISTED MIXING VALVE SET TO 109'F, TAILPIECE, P—TRAP, SUPPLY <br />CARRIER: ZURN Z1231 <br /># <br />& STOPS. INSULATE EXPOSED PIPING WITH TRUEBRO LAV GUARD KIT. <br />TANKLESS <br />TWH-1 <br />-- <br />-- <br />1/2" <br />1/2" <br />EEMAX # EMT1 <br />MINI —TANK WATER HEATER, 1.6—GALLONS, UL—LISTED, ELECTRONIC, <br />WATER HEATER <br />WATTS # LFMMV <br />WALL MOUNT, 1.44—KW ® 120—VOLT. <br />PROVIDE ASSE 1017 & 1070 MIXING VALVE SET TO 1097. <br />ICE BOX <br />IB-1 <br />-- <br />-- <br />1 /2" <br />-- <br />GUY GRAY # BIM875 <br />ICE MAKER BOX: GALVANIZED STEEL BOX, 20 GA., 18 GA. FACEPLATE, <br />(# BIM876 FOR CPVC) <br />1/4—TURN STOP, COMBINATION MIP OR SWEAT CONNECTION. <br />PROVIDE ADDITIONAL CHECK VALVE & WATER HAMMER ARRESTOR. <br />FLOOR DRAIN <br />FD-1 <br />3" <br />2" <br />-- <br />-- <br />ZURN # Z415B <br />DURA—COATED CAST IRON BODY, 6" DIAMETER BRONZE ADJUSTABLE STRAINER. <br />ZURN # Z1072 <br />PROVIDE 4" DEEP TRAP AND BARRIER —TYPE TRAP PROTECTION (ASSE 1072). <br />FLOOR SINK <br />FS-1 <br />3" <br />2" <br />-- <br />-- <br />ZURN # Z-1900-3 SANI—FLOOR RECEPTOR <br />12"x12%6" DEEP CAST IRON BODY AND SECURED 3/4—GRATE WITH WHITE <br />WITH GRATE 3 4 <br />/ <br />ACID RESISTING PORCELAIN ENAMEL INTERIOR AND TOP. COMPLETE WITH <br />ALUMINUM ANTI —SPLASH INTERIOR BOTTOM DOME STRAINER. <br />THERMAL MIXING <br />TMX-1 <br />-- <br />-- <br />3/8" <br />3/8" <br />WATTS # LFUSG—B <br />MIXING VALVE: PROVIDE AT EACH HAND SINK AN IN —LINE MIXING VALVE, <br />VALVE <br />ASSE 1070 APPROVED, SET AT 109-F IN THE HW SUPPLY TO FIXTURE. <br />FLOOR CLEANOUT <br />FCO <br />SEE <br />-- <br />-- <br />-- <br />ZURN # Z1400—BZ <br />"LEVEL—TROL" ADJUSTABLE FLOOR CLEANOUT, DURA—COATED <br />PLAN <br />CAST—IRON, POLISHED BRONZE TOP, ADJUSTABLE TO FLOOR FINISH. <br />WALL CLEANOUT <br />WCO <br />SEE <br />-- <br />-- <br />-- <br />ZURN # Z1468 <br />WALL CLEANOUT — ROUND STAINLESS STEEL WALL ACCESS COVER <br />PLAN <br />WITH SECURING SCREW AND BRONZE RAISED HEX HEAD PLUG. <br />GOTG " <br />GREASE TRAP SIZING <br />RESTAURANTS <br />SEATS = 85 DINING SEATS <br />GALLONS OF WASTE PER SEAT = 25 GALLONS <br />(10—SINGLE SERVICE; 25—DISHMACHINE/CHINA) <br />HOUR OF OPERATION = 8 HOURS / 12 <br />LOADING FACTOR = 1.0 OTHER HIGHWAY <br />85 X 25 X 8/12 X 1.0 = 1,417—GALLONS <br />(1) 1,500—GALLON GREASE INTERCEPTOR EXISTING <br />SIZING BASED ON FL.ADMIN.CODE RULE#64E-6, PER <br />FBC—PLBG, 1003.3.4, EXCEPTION, USING AN OUTDOOR <br />GREASE INTERCEPTOR. <br />TOTAL DRAINAGE FIXTURE <br />UNITS PER FBC—P TABLE <br />709.1 — 10.0 DFU <br />� ► !r.vwm Lziej n <br />(E)1 —1 /2"GAS <br />I <br />EXISTING GAS <br />TANKLESS WATER <br />HEATER (199—MBH) <br />FCD <br />�1 EXISTING GAS <br />F'p, METER TO REMAIN <br />RANGE <br />1 88—MBH <br />I <br />t� I <br />`/EXISTING GAS COCK <br />/ & ANSUL VALVE <br />1 "GAS <op'/ (E)1 —1 /2"GASH.' \® <br />MANIFOLD <br />36" GRIDDLE <br />120—MBH <br />60" GRIDDLE <br />120—MBH <br />I � <br />FRYER <br />r 10s—MBH <br />FRYER <br />(E)DIRT LEG 105—MBH <br />GAS PIPING SIZED BASED ON <br />804—MBH ® 1/2—PSI <br />DELIVERY AND TOTAL <br />EQUIVALENT PIPING LENGTH <br />OF 50—FT MAX. <br />(SEVENTH ED. FLORIDA FUEL <br />GAS CODE TABLE 402.4(2)) <br />-i�®1�� �-4 <br />1 <br />p <br />CONNECT TO J <br />(E)3/4"CW ABOVE <br />RESTROOM _ <br />r'� <br />�(E)3/4"HW TO <br />/2e (E)KITCHEN <br />1 C� EQUIPMENT <br />1, <br />EXISTING GAS <br />TANKLESS WATER <br />HEATER (199—MBH) <br />TO REMAIN i SEE FIXTURE SCHEDULE FOR <br />BRANCH SIZES TO FIXTURES <br />TOTAL WATER FIXTURE <br />UNITS PER FBC—P TABLE <br />E103.3(2) — 12.9 WFU <br />�_(E)3/4"CW WATER ISOMETRIC RISER <br />avG LLB NONC <br />WALL —SEE FLOOR PLANS <br />SUPPLY PIPE —SEE PLUMB <br />BLOCKING BETWEEN STUDS <br />PIPE TO EQUIP. FIXTURE <br />SILICON CAULK—FSE AREAS <br />QUARTER —TURN <br />ANGLE STOP (TYP) <br />CHROME TRIM <br />ELBOW W/ANCHOR FLANGE <br />FIXTURE SHUT- OFF VALVE <br />NOT TO SCALE <br />MAY EXTEND AS A WASTE OR <br />VENT. REFER TO PLANS. —\ <br />CHROME WALLCOVER <br />& SCREW <br />.......... .. a..t <br />BALANCE OF PIPING SAME <br />AS CLEANOUT TO GRADE - <br />WALL <br />PLUGGED TEE <br />W/CLEANOUT <br />FLOOR LINE <br />GRADE OR PAVING <br />CLEANOUT <br />ASSEMBLY <br />SAME SIZE AS SEWER <br />UP TO 8" DIA. <br />SEWER MATERIAL <br />AND SIZE AS <br />SPECIFIED <br />COVER FOR <br />DUTY REQUIRED <br />a <br />> <br />6" THICK CONCRETE <br />BEND OR COMBINATION <br />LONG SWEEP 1/4 <br />"Y" AND 1 /8 BEND <br />2- WAY GRADE CLEANOUT DEV& (COTG) <br />SCALE: NONE <br />CLEANOUT & ACCESS COVER TO BE <br />FLUSH W/TOP OF FLOOR FLOOR LINE <br />c q <br />BALANCE OF PIPING SAME <br />AS CLEANOUT TO GRADE - <br />FLOOR CLEANOUT (F.C.O.) <br />1 /8" BEND NOT TO SCALE C.O. NOT TO BE LOCATED <br />IN CARPETED AREA, <br />WALL CLEANOUT <br />NOT TO SCALE <br />CAST B/ <br />TILE, 1 / <br />SLOPE N <br />LATICRE' <br />WATERPf <br />MEMBRA <br />119fiffl(1 <br />DRAIN A <br />COLLAR <br />FLOOR <br />FLOOR DRAIN WITH TRAP GUARD DETAIL <br />SCALE: NONE <br />TILE, SLOPE 1 /4"/FT. - <br />WATERPROOF MEMBRANE <br />CAST IRON 3/4 GRATE <br />DOME STRAINER <br />CLAMP RING <br />CONC. <br />FOR SINK SIZE AND <br />TYPE, SEE PLUMBING <br />FIXTURE SCHEDULE <br />AND SPEC. <br />FLOOR SAC DETAIL <br />SCALE: NONE <br />TDAD 011ADn INSERT <br />;ERTIFIED) <br />M00 0) <br />N cn o - <br />LAJ N <br />N <br />J <br />< J <br />Y V Li <br />W (f) o I o a <br />ZQ w-,;;M0 <br />a <br />Q Q W U M.41 vi <br />Lij Z��N J <br />cNv3a� � <br />w <br />10 <br />0 <br />L <br />Q N <br />C�_o <br />Q <br />� <br />N <br />m <br />12 <br />C <br />0 10 <br />k c <br />�- <br />3 <br />� <br />N <br />Q @ <br />E <br />a <br />_ <br />d n. <br />4-% <br />a¢ <br />d <br />Q <br />AO <br />— <br />R/ <br />C� <br />Z <br />Q <br />O <br />W <br />—► <br />< <br />Ca <br />t0 <br />0 <br />cv_ <br />0 <br />(-- <br />� <br /><< <br />J <br />lti <br />L <br />O <br />L <br />0z <br />Z <br />-i- pCo- <br />i- <br />ao <br />W <br />N <br />t4 <br />I" <br />f'-W u D <br />�GF NS lLi'. <br />Nc 5ta1}3y <br />* <br />* <br />G. IATf 0 <br />Date: 4. 25. 22 <br />Checked by: NIL <br />Drawn: T.1/KB <br />Job: 21-012 <br />Sbccl <br />P002 <br />IL <br />
The URL can be used to link to this page
Your browser does not support the video tag.