My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7441 Gall Blvd (2)
Zephyrhills
>
Building Department
>
Building Plans
>
7441 Gall Blvd (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 11:00:24 PM
Creation date
2/18/2025 3:39:30 PM
Metadata
Fields
Template:
Building Plans
Street #
7441
Location
Gall Blvd
Contractor
Wallace Associates
Building Plans - Permit #
14068
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MINIMUM CODE REQUIRED OUTSIDE AIR VENTILATION RATES PER ASHRAE STANDARD AzRa+PzRt? =Voz <br />62.1-2010 Ez <br />NET <br />AREA <br />CODE <br />NUMBER <br />PEOPLE <br />CODE <br />CODE <br />ZONE AIR <br />TOTAL OA <br />DEFAULT <br />AREA <br />OUTDOOR <br />REQ'D <br />PEOPLE <br />OUTDOOR <br />REQ'D OA <br />REQ'D OA <br />DISTRIBUTION <br />REQUIRED <br />OCCUPANT <br />AIR RATE <br />BASED ON <br />AIR RATE <br />BASED ON <br />TOTAL <br />EFFECTIVENESS <br />BY <br />DENSITY <br />FLOOR <br />PEOPLE <br />VBz <br />CODE <br />AREA <br />Az <br />Ra <br />Pz <br />PIP <br />AzRa +FzRp <br />I Ez <br />Voz <br />AREA -SERVED <br />OCCUPANCY <br />CATEGORY <br />P/1000 SF <br />SF <br />CFM/SF. <br />CFM <br />PERSON(S) <br />CFM/PERS <br />CFM <br />CFM <br />CFM <br />KITCHEN <br />FAST FOOD <br />100 <br />1250 <br />0.18 <br />225 <br />+ <br />4 <br />1.5 <br />30 <br />255 <br />/ <br />0.8 <br />x <br />319 <br />SEATING <br />CAFETERIA <br />100 <br />1150 <br />0.18 <br />201 <br />+ <br />20 <br />1.5 <br />150 <br />351 <br />/ <br />0.8 <br />351 <br />+ <br />/ <br />_ <br />TOTAL REQUIRED <br />616 <br />TOTAL PROVIDED <br />2180 <br />,AIR 5ALANCE SCHEDULE <br />TAG <br />SUPPLY <br />AIR <br />OUTSIDE <br />RETURN <br />AIR <br />EXHAUST <br />AIR <br />BLDG. <br />221SSU <br />q.OUTSIDE <br />AI <br />(E)RTU-1 <br />4500 CFM <br />90o CFM <br />3600 CFM <br />+ 90o CFM <br />20 <br />(E)RTU-2 <br />6400 CFM <br />1280 CFM <br />5120 CFM <br />+ 1280 CFM <br />2 <br />( F-I <br />--- <br />--- <br />- -- <br />200 CFM <br />- 200 CFM r <br />F-2 <br />--- <br />--- <br />--- <br />e35 CFM <br />- C335 CFM <br />--- <br />F_ <br />___ <br />___ <br />___ <br />935 CFM <br />- 935 GFM <br />--- <br />TOTAL <br />10900 CFM <br />2180 CFM <br />8120 CFM <br />2070 CFM <br />+ 110 CFM <br />2 <br />AIR DEVICE SCHEDULE , <br />MANUFACTURER <br />MARK <br />TYPE <br />MATERIAL <br />FINISH <br />ACCESSORIES <br />AND MODEL <br />REMARKS <br />CD <br />CEILING <br />ALUMINUM <br />BAK. WHT. <br />OBD <br />PRICE <br />DIFFUSER <br />ENAMEL <br />AMD <br />RRG <br />RETURN <br />ALUMINUM <br />BAK. WHT. <br />OBD <br />PRICE <br />REGISTER <br />ENAMEL <br />630FL <br />f <br />OMECHANICAL PLAN <br />SCALE: 1/4" = 1'-0" <br />EXISTING RTU UNIT SC - EDULE <br />MARK <br />- <br />(E)RTU-1 <br />(E)RTU-2 <br />SUPPLY AIR <br />CFM <br />4500 <br />6400 <br />OUTSIDE AIR <br />CFM <br />900 <br />1250 <br />EXT. STATIC PRESSURE <br />IN. H (? <br />OB <br />0.5 <br />FAN SPEED <br />RPM <br />EXISTING <br />EXISTING <br />MOTOR <br />H.P. <br />EXISTING <br />EXISTING <br />POWER <br />VOLTS/PH. <br />230/3 <br />230/3 <br />FILTER TYPE <br />- <br />(4)20X2OX2 <br />(4)2OX2OX2 <br />TOTAL COOLING CAPACITY <br />BTUH <br />146,000 <br />244,500 <br />SENSIBLE COOLING CAPACITY <br />BTUH <br />111,000 <br />160,000 <br />ENT. AIR TEMP. <br />IF/IF <br />60/61 <br />80/61 <br />LVG. AIR TEMP <br />IF/IF <br />EXISTING <br />EXISTING <br />HEATING CAPACITY <br />MBH <br />EXISTING <br />EXISTING <br />EER <br />BTU/WATT <br />11 <br />10 <br />AMBIENT TEMP. <br />'F <br />95 <br />95 <br />UNIT WEIGHT <br />L55. <br />EXISTING <br />EXISTING <br />MANUFACTURER <br />- <br />TRADE <br />TRANE <br />MODEL NO. <br />- <br />YCD150 <br />YCD240 <br />NOTES <br />" <br />I <br />I <br />OI EXISTING RTU TO REMAIN. CONTRACTOR TO VERIFY LOCATION, PROPER OPERATION <br />AND SERVICE IT AS REQUIRED. <br />MAX. 20' <br />TRANSITION <br />�025 D (4" MIN. PER SMACNA) <br />T RECTANGULAR DUCT <br />125 r, D <br />VOLUME DAMPER <br />CONICAL FITTING WITH LOCKING TYPE VOLUME DAMPER <br />/_�OR SIDE WALL TAKEOFF EQUAL TO FLEXMASTER STO. <br />2 )1 BRANCH DUCT DETAILS <br />SUPPLY DUCT <br />FLEX DUCT OR ROUND SHEET METAL DUCT. FLEX <br />DUCT MAX. 8'-0" LONG, USE CLAMP TO ATTACH <br />FLEX DUCTS AND SEAL. SUPPORT <br />DUCT EVERY FOUR FEET FROM STRUCTURE <br />SEE BRANCH DUCT DETAIL <br />ROUND METAL DUCT <br />(EXTERNAL INSULATION) <br />CEILING <br />OI GEILINCx DIiFIJSER RLINOUt DETAIL <br />NO SCALE <br />INSULATED ROUND <br />FLEXIBLE DUCT <br />(MAX. 8'-0" LONG) <br />SIZE TO MATCH <br />DIFFUSER NECK <br />INSULATION <br />MECHANICAL LEGEND <br />1 SYMBOL 1 DESCRIPTION 1 <br />NEW DUCTWORK, PIPING, OR EQUIPMENT <br />r <br />- — — _ — _ - S _ _ _ _ EXISTING DUCTWORK, PIPING, OR EQUIPMENT <br />TO REMAIN <br />FLEXIBLE DUCT <br />® SUPPLY OR OUTSIDE AIR DUCT SECTION <br />RETURN OR EXHAUST DUCT SECTION <br />U/��� ►��� EXISTING DUCTWORK, PIPING, OR EQUIPMENT TO BE <br />1 A �7_127_-r REMOVED <br />DUCTWORK TRANSITION <br />MANUAL AIR VOLUME CONTROL DAMPER <br />MOTORIZED DAMPER (24 VOLTS) <br />® SUPPLY AIR DEVICE. CLEAR TRIANGLE SIDES <br />INDICATE AIR FLOW PATTERN <br />RETURN OR EXHAUST AIR DEVICE <br />Q CONNECTION BETWEEN NEW AND EXISTING WORK <br />T� <br />EXISTING WALL MOUNTED THERMOSTAT <br />CD <br />CEILING DIFFUSER <br />RRC <br />RETURN REGISTER AT CEILING <br />RGC <br />RETURN GRILLE AT CEILING <br />ERC <br />EXHAUST REGISTER AT CEILING <br />(E) <br />EXISTING <br />MECHANICAL GENERAL NOTES: <br />1 I I. IN GENERAL, PLANS AND DIAGRAMS ARE SCHEMATIC ONLY AND SHOULD NOT BE SCALED. <br />CEILING DIFFUSER <br />NO SCALE <br />2, INTENT OF THESE NOTES AND MECHANICAL NOTES ON DRAWINGS IS TO CLARIFY THE <br />SCOPE OF WORK AND ALERT CONTRACTOR OF EXISTING CONDITIONS. CONTRACTOR TO <br />VISIT SITE AND VERIFY ALL CLEARANCES BEFORE FABRICATION OF DUCTWORK AND <br />PROVIDE ADDITIONAL OFFSET AND/OR CHANGES IN DUCT SIZES TO MEET FIELD <br />CONDITIONS AND COORDINATE WITH ELECTRICAL, PLUMBING AND FIRE PROTECTION <br />SUBCONTRACTOR BEFORE ANY CONSTRUCTION WORK <br />3, CONTRACTOR SHALL NOTIFY THE OWNER, ARCHITECT OR HI5 AUTHORIZED <br />REPRESENTATIVE OF ANY DAMAGE TO THE EXISTING INSTALLATION BEFORE PROCEEDING <br />WITH THE WORK <br />4. COORDINATE AIR DEVICE LOCATIONS WITH LIGHTING FIXTURES AND FIRE SPRINKLER <br />HEADS. <br />5. DUCT DIMENSIONS SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS. <br />6. ALL SUPPLY AIR DIFFUSERS SHALL BE 4-WAY THROW UNLESS OTHERWISE NOTED. <br />CONTRACTOR SHALL PROVIDE A COPY OF THE TEST AND BALANCE REPORT AT THE <br />FINAL INSPECTION. THIS REPORT MUST BE REVIEWED AND APPROVED BY THE ENGINEER <br />PRIOR TO THE FINAL ACCEPTANCE. <br />1. THE GENERAL CONTRACTOR 15 RESPONSIBLE FOR ALL TRADES INSTALLATION <br />SCHEDULES. FIXED WORK SUCH AS DUCTWORK AND PLUMBING SHALL BE INSTALLED <br />PRIOR TO ANY TRADE WORK THAT CAN BE EASILY RELOCATED OR OFFSET SUCH AS <br />ELECTRICAL CONDUITS, SMALL WATER LINES ETC. <br />8. CONTRACTOR SHALL PROVIDE ALL SUPPLEMENTARY STEEL REQUIRED TO SUSPEND a <br />MECHANICAL EQUIPMENT AND MATERIALS. <br />✓ t <br />S. FLEXIBLE AND RIGID ROUND DUCT TAKE -OFFS FOR DIFFUSERS SHALL BE THE SAME SIZE <br />AS DIFFUSER NECK MAXIMUM FLEXIBLE DUCT LENGTH SHALL BE 8'-0" <br />10. ALL MECHANICAL WORK SHALL MEET ALL THE REQUIREMENTS OF THE "2010 FLORIDA <br />BUILDING CODE, MECHANICAL". <br />11. IT 15 THE RESPONSIBILITY OF THE MECHANICAL INSTALLER TO PATCH AND REPAIR ANY <br />DUCT OPENINGS WHICH RESULT FROM THE RELOCATION OR ELIMINATION OF ANY EXISTING <br />AIR DEVICES. THE PATCH IS TO BE OF A SIMILAR MATERIAL TO THE REPAIRED DUCT AND <br />TO BE SEALED IN ACCORDANCE WITH SMACNA STANDARDS. <br />12. ALL EXHAUST DUCTS SHALL BE GALVANIZED SHEET METAL. <br />IMPORTANT NOTES FOR CONTRACTOR AND SUBCONTRACTOR: <br />ANY DISCREPANCIES OR OMISSIONS ON THESE DOCUMENTS MUST BE BROUGHT TO THE <br />ATTENTION OF THE ARCHITECT PRIOR TO THE COMMENCEMENT OF CONSTRUCTION AND BID <br />TO OWNER. FAILURE BY CONTRACTOR TO IDENTIFY DISCREPANCIES OR OMISSIONS WILL <br />THEN BECOME THE RESPONSIBILITY OF THE CONTRACTOR. <br />CONTRACTOR SHALL COORDINATE RELOCATED AIR DEVICE LOCATIONS ON SITE WITH THE <br />NEW REFLECTED CEILING PLAN AS NEEDED. <br />HVAC SYSTEM AND DUCTWORK IS EXISTING TO REMAIN WITHOUT MODIFICATIONS. LAYOUT <br />SHOWN IN PLAN 15 SCHEMATIC ONLY AND MUST BE FIELD VERIFIED. <br />THE HVAC CONTRACTOR SHALL FIELD VERIFY LOCATIONS OF THE EXISTING (E)AIR <br />DEVICES, (E)RTU'5, (E)T-5TAT AND (E)DUCT WORK <br />SEQUENCE OF OPERATIONS: <br />UNIT SHALL CEASE OPERATION UPON DETECTION OF SMOKE. <br />(E)RTU-I t 2: <br />UNIT SHALL BE CONTROLLED BY ITS ELECTRONIC 1-DAY PROGRAMMABLE T-STAT. UNIT <br />SUPPLY FAN SHALL RUN <br />CONTINUOUSLY IN THE OCCUPIED MODE, CYCLE WITH HEATING AND COOLING3 <br />WHILE UNOCCUPIED. UPON A RISE IN SPACE TEMPERATURE, UNIT COMPRESSOR AND <br />CONDENSER FANS SHALL ACTIVATE IN STAGE TO SATISFY SPACE. UPON A DROP IN SPACE <br />TEMPERATURE, GAS HEAT SHALL BE ACTIVATED IN STAGE TO SATISFY SPACE <br />TEMPERATURE. <br />OCCUPANCY SCHEDULE SHALL BE SET OCCUPIED/UNOCCUPIED BASED ON TENANT <br />SPECIFIC <br />REQUIREMENTS. THERMOSTAT SHALL BE SET FOR OCCUPIED COOLING 15't OCCUPIED <br />HEATING <br />10'± UNOCCUPIED COOLING 80'± UNOCCUPIED HEATING 60'. ALL TIME AND TEMPERATURE <br />SETPOINTS <br />SHALL BE VERIFY BY LANDLORD AND TENANT PRIOR TO PROGRAMMING. THERMOSTAT <br />SHALL BE PROGRAMMED <br />BY MECHANICAL CONTRACTOR IN THE PRESENCE OF TENANT'S REPRESENTATIVE. <br />DEMOLITION NOTE: <br />EXISTING ROUND DIFFUSER TO BE REPLACED WITH 24" SQUARE DIFFUSER. <br />COORDINATE LOCATION WITH NEW REFLECTED CEILING PLAN. <br />®REMOVE AND DISPOSE EXISTING HOOD(S), ASSOCIATED DUCTWORK AND <br />FAN(S) AS DIRECTED BY OWNER. <br />REVISIONS <br />BY <br />� � r <br />„ u <br />♦ o i.) c <br />7 y <br />it ¢ .c ~ <br />3 ti 3 <br />y ti <br />cti <br />o d <br /><� <br />1 <br />i <br />'z�z=EW+ <br />Cox? 0- <br />all <br />i <br />CT <br />0 <br />�0nd <br />c, <br />� <br />i.0 <br />o.z_= <br />00 <br />M 00 <br />V N <br />C `O C <br />� <br />W ' u') <br />� N <br />m <br />o2 w y M <br />CIt <br />O L <br />y 10 <br />A` <br />xLL <br />a <br />E <br />L <br />O <br />� Z <br />� W <br />o Y v <br />o V v <br />O O <br />m LL- <br />� Vl <br />v <br />o N <br />•� LIU �. <br />X d <br />w L d a� <br />i CL IV <br />o p <br />Date: 03. 28. 13 <br />Scale: AS NOTED <br />Project Mgr: GGS <br />Drawn: ES <br />Job: 13-03 <br />Sheet <br />M 2 <br />