Laserfiche WebLink
I - loll) �R -.1 <br />EX <br />EX <br />EX Ex 111 <br />O PNL EX <br />MDP PNL <br />EX EX <br />ADD <br />EX 0mc <br />MLO <br />EX <br />EX <br />GR ROD <br />Ex EX <br />EX <br />GR. ROD <br />EXI EX <br />PNL PNL <br />A K <br />225A 2504 <br />MLO MLO <br />EX <br />BLDG STEEL <br />RISER NOTES O <br />1_ EXISTING PANEL INSIDE OF THE SLICE TABLE <br />TO BE DEMOLISHED_ PROS/IDE FINAL <br />CONNECTION TO NEW PANEL 'D' IN511DE OF THE <br />NEW SLICE TABLE. PANEL 'D' IS PROVIDED 5Y <br />SLICE TABLE MANUFACTURER_ COORDINATE <br />EXACT LOCATION AND REQUIREMENTS WITH <br />N SLICE TABLE EQUIPMENT INSTALLER AND GENERAL <br />D 1 CONTRACTOR. <br />125A MCB 2, EG SHALL RE -USE AND EXTEND EXISTING <br />CONDUIT FROM PANEL 'MDP' TO NEW PANEL 'D' <br />LOCATION AND EXTEND NEW 4 #1 AND 1 #& EG. <br />IN EXISTING/EXTENTED CONDUIT. <br />�I ELECTRICAL RISER DIAGRAM <br />SCALE: NOT TO SCALE <br />DATE: <br />05-29-15 <br />REVISED: <br />FAULT CURRENT STUDY <br />CABLE IMPEDANCE VALUES BASED ON IEEE STD. 241-1990, TABLE 65. <br />PROJECT: <br />ARBYS GAIL BLVD. <br />ZEPHYRHILLS, FL <br />SYSTEM VOLTAGE: <br />208 <br />WIRE TYPE CU=1 <br />ASSUMED BASE KVA: <br />150 <br />WIRE TYPE AL=2 <br />UTILITY COMPANY AFC: <br />20833 <br />PVC CONDUIT <br />UTILITY COMPANY X/R RATIO: <br />12 <br />SOURCE <br />SOURCE <br />WIRE <br />WIRE # OF <br />FEEDER <br />BUS <br />BUS <br />BUS <br />AFC <br />X/R <br />SIZE <br />TYPE RUNS <br />LENGTH <br />X/R <br />AFC <br />------------------------------------ <br />i PNL 'M' <br />-------------------------------- <br />20833 <br />---------------- <br />12.00 <br />---------------- <br />350 <br />-------------------------------- <br />1 2 <br />---------------- <br />65 <br />---------------- <br />4.54 <br />17360 <br />PNL 'D' <br />17360 <br />454 <br />1 <br />1 1 <br />55 <br />101 <br />9R62 <br />FAULT CURRENT STUDY NOTE: <br />1. THE ELECTRICAL CONTRACTOR SHALL OBTAIN A LETTER FROM UTILITY COMPANY FOR THE AVAILABLE FAULT <br />CURRENT AT THE SECONDARY TERMINALS AT THE INSTALLED UTILITY TRANSFORMER NOTIFY ENGINEER IF THE <br />AVAILABLE FAULT CURRENT EXCEEDS THE BASIS OF DESIGN. <br />PANEL. <br />A <br />EXISTING <br />FLUSHMOUNTED <br />120`208 VOLT 3 PHA SE <br />4 WIRE W ITH C ROUND <br />225A MLO <br />NE14 A 1 <br />NOTES <br />CKT. <br />DESCRIPTION <br />BREAKER <br />A <br />B <br />C <br />BREAKER <br />DESCRIPTION <br />CKT. <br />NOTES <br />N0. <br />TRIP <br />POLE <br />VOLT <br />VOLT <br />POLEI <br />TRIP <br />N0. <br />2 <br />1 <br />POS <br />20 <br />1 <br />120 <br />1000 1_-00 <br />120 <br />1 <br />20 <br />DRIVE THRU SIGIN (") <br />2 <br />1 <br />5 <br />3 <br />ACTIVE <br />20 <br />1 <br />120 <br />1000 <br />360 <br />120 <br />1 <br />20 <br />OFFICE RECEPTACLE(** <br />4 <br />2 <br />5 <br />5 <br />REAR <br />20 <br />1 <br />120 <br />1000 <br />1 360 <br />120 <br />1 <br />20 <br />1 KITCHEN CONY RECEPT. (* *) <br />61 <br />2 <br />2 <br />7 <br />POS <br />20 <br />1 <br />120 <br />1000 180 <br />120 <br />1 <br />15 <br />AHU-1 (**) <br />8 <br />5 <br />1 <br />9 <br />COOLERLIGHTS <br />20 <br />1 <br />120 <br />1000 <br />1450 <br />208 <br />2 <br />15 <br />CU-I(**) <br />10 <br />3 <br />5 <br />11 <br />ACTIVE <br />20 <br />1 <br />120 <br />1000 <br />1450 <br />--- <br />12 <br />3 <br />2 <br />13 <br />POS <br />20 <br />1 <br />M <br />1000 1500 <br />208 <br />2 <br />30 <br />POLELIGHTS PARKING <br />14 <br />1 <br />5 <br />15 <br />ACTIVE <br />20 <br />1 <br />120 <br />1000 <br />1500 <br />--- <br />16 <br />1 <br />5 <br />171 <br />ACTIVE <br />20 <br />1 1 <br />120 <br />1000 <br />1000 <br />LO <br />1 <br />20 <br />ACTIVE <br />18 <br />5 <br />5 <br />19 <br />ACTIVE <br />20 <br />1 <br />120 <br />1000 1000 <br />U0 <br />1 <br />20 <br />ELIGHTS <br />20 <br />1 <br />5 <br />21 <br />AC?14E <br />N <br />1 <br />120 <br />1000 <br />1000 <br />120 <br />1 <br />20 <br />ACTIVE <br />22 <br />5 <br />5 <br />23 <br />ACTIVE <br />20 <br />1 <br />120 <br />1000 <br />1000 <br />120 <br />1 <br />20 <br />ACTIVE <br />24 <br />5 <br />1 <br />25 <br />LTS <br />20 <br />1 <br />im <br />1000 1000 <br />120 <br />1 <br />20 <br />ACTIVE <br />26 <br />5 <br />1 <br />171 <br />LTS <br />20 <br />1 <br />120 <br />1000 <br />1000 <br />120 <br />1 <br />20 <br />ACTIVE <br />28 <br />5 <br />1 <br />291 <br />LTS <br />20 <br />1 1 <br />120 <br />1000 <br />1000 <br />120 <br />1 <br />20 <br />ACTIVE <br />30 <br />5 <br />1 <br />31 <br />LTS <br />20 <br />1 <br />120 <br />1000 1000 <br />LO <br />1 <br />20 <br />ACTIVE <br />32 <br />5 <br />1 <br />33 <br />LTS <br />20 <br />1 <br />M <br />1000 <br />1000 <br />LO <br />1 <br />20 <br />ACTIVE <br />341 <br />5 <br />1 <br />35 <br />LTS <br />20 <br />1 <br />120 <br />1000 <br />1000 <br />120 <br />1 <br />20 <br />ACTIVE <br />36 <br />5 <br />5 <br />37 <br />EWH <br />50 <br />3 <br />208 <br />4000 <br />120 <br />1 <br />20 <br />SPARE <br />38 <br />5 <br />1 391 <br />LO <br />1 <br />20 <br />SPARE <br />40 <br />5 <br />1 411 <br />4000 1000 <br />120 <br />1 <br />20 <br />BATH <br />42 <br />2 <br />CONNECTED <br />SYSTENI <br />PHASEANiPS <br />VA <br />VOLTS <br />15M <br />16310 <br />16810 <br />140 <br />NOTE() <br />*.UTILIZE EXISTING SPARE BREAKER FORT TS CIRCUIT. <br />**. PROVIDENEW CIRCUIT BRFAKER NE�A7 CIRCUIT BREAKER <br />TOMATCHEXISTINIGPA FLNiFR,TI?EAVDAICRATING <br />120/208V, 3 PHASE <br />132 <br />136 <br />'VOTES <br />LOADTYPE <br />IS LARGER <br />CONNECTED <br />NECDENiAND <br />DENIANDLOAD <br />1 <br />LIGHTING <br />12200 <br />125 <br />15250 VA <br />4720 VA <br />2900 VA <br />0 VA <br />29180 VA <br />0 VA <br />0 VA <br />52050 VA <br />2RECEPTACLES <br />4720 <br />1 <br />3 <br />AIRCONDITIONI.NG <br />2900 <br />1 <br />4 <br />HEATING <br />0 <br />0 <br />5 <br />MISC. NON -CONTINUOUS <br />29180 <br />1 <br />6 <br />CONTINUOUS <br />0 <br />1.25 <br />7 <br />KITCHEN <br />0 <br />0.65 <br />TOTAL <br />120/208V, 3 PHASE <br />I <br />I145 AMP <br />ELECTRICAL PANEL GENERAL NOTE: <br />1, SOME OF THE EXISTING CIRCUIT BREAKER AMPS RATINGS ARE NOT LEGIBLE. CONTRACTOR SHALL FIELD <br />VERIFY EXISTING BRANCH CIRCUIT TYPE LOADS AND WIRE SIZES OF THESE CIRCUIT BREAKERS AND REPLACE <br />THEM WITH NEW CIRCUIT BREAKERS PER NEC. NEW CIRCUIT BREAKERS TO MATCH PANEL MANUFACTURER, TYPE <br />AND AIC RATING. <br />D LECTRICAL PAL 85CWEDULES <br />SCALE:: NOT TO SCALE <br />REVISIONS <br />BY <br />.f, <br />�00 <br />U C: <br />< — <br />E <br />�rtti° <br />- � n <br />U <br />L7 Q <br />_ c 3 <br />� o <br />U <br />W <br />N_ <br />U <br />No. <br />06-09-15 <br />�n�Idd9141.� <br />J - . <br />3 <br />'n U <br />O — <br />J <br />� n <br />J <br />W <br />L <br />O <br />0 <br />C <br />O <br />v � <br />> •FZ <br />c O <br />O _ <br />(n m LL. <br />N <br />.p mrZ <br />O � _ <br />X (O �- <br />>` <br />W It _ <br />,q* <br />c rl- a <br />� <br />v IV <br />L_ <br />O <br />O <br />C <br />Date: 06. 09. 15 <br />Scale: AS NOTED <br />Project Mgr: RNS <br />Drawn: IT/WR <br />Job: 15-50 <br />Sheet <br />E3 <br />