My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7495 Gall Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
7495 Gall Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 7:22:55 PM
Creation date
2/18/2025 3:40:09 PM
Metadata
Fields
Template:
Building Plans
Street #
7495
Location
Gall Blvd
Contractor
Schroeder Architects
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
84
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CODE INFORMATION <br />APPLICABLE CODES <br />2020 FLORIDA BUILDING CODE (FBC): BUILDING <br />2020 FLORIDA BUILDING CODE: ENERGY CONSERVATION <br />2020 FLORIDA BUILDING CODE: MECHANICAL <br />2020 FLORIDA BUILDING CODE: PLUMBING <br />2020 FLORIDA BUILDING CODE: GAS <br />2020 FLORIDA FIRE PREVENTION CODE, 7TH EDITION <br />2020 NATIONAL FIRE PROTECTION ASSOCIATION - NFPA 101 LIFE SAFETY CODE <br />2017 NATIONAL ELECTRICAL CODE - NFPA 70 <br />2020 FLORIDA WIND MAP <br />LIFE SAFETY INFORMATION <br />OCCUPANCY: <br />FBC: MERCANTILE (M) <br />NFPA 101: NEW MERCANTILE OCCUPANCY <br />CONSTRUCTION TYPE: <br />FBC: TIME II-B UNPROTECTED <br />NFPA 101: TYPE II-000 <br />BUILDING HEIGHT: <br />ALLOWABLE: 3 STORIES, 75FT, (TABLE 503 & <br />SECT. 504.2) <br />ACTUAL: 1 STORY, 28'-0", MAX. (18'-0- TO ROOF DECK) <br />BUILDING AREA: <br />ALLOWABLE: 12,500 <br />ACTUAL: 3,407 S.F., BUILDING. <br />FIRE RESISTANCE RATING <br />STRUCTURAL FRAME: <br />0 HRS <br />BUILDING ELEMENTS <br />BEARING WALLS (INTERIOR AND EXTERIOR): <br />0 HRS <br />(FBC TABLE 601 & 602) <br />NON -BEARING EXTERIOR WALLS: <br />(NFPA 220 TABLE 4.1.1) <br />X < 5 <br />1 HRS <br />5 </= X < 10 <br />1 HRS <br />10</=X<30 <br />0HRS <br />30 </= X <br />0 HRS <br />NON -BEARING INTERIOR WALLS: <br />0 HRS <br />FLOOR CONSTRUCTION: <br />0 HRS <br />ROOF CONSTRUCTION: <br />0 HRS <br />ACTUAL: <br />NO SHAFTS IN THIS PROJECT. <br />INTERIOR WALL AND <br />EXIT ENCLOSURES AND EXIT PASSAGEWAYS: <br />CLASS B <br />CEILING FINISHES: <br />CORRIDORS: <br />CLASS B <br />_ (ASTM E 84, FBC TABLE 803.9) <br />ROOMS AND ENCLOSED SPACES: <br />CLASS C <br />INTERIOR FLOOR FINISHES: <br />MINIMUM CRITICAL RADIANT FLUX: <br />CLASS II <br />(DOC FF-1, FBC SECTION 804) <br />CORRIDOR RATING: <br />0 HR (FBC TABLE 1018.1) (NFPA 101 12.3.6) <br />VERTICAL EXIT ENCLOSURES: <br />NO VERTICAL EXIT ENCLOSURES IN THIS PROJECT. <br />EXIT ACCESS TRAVEL DISTANCE: <br />250 FT. (FBC TABLE 1016.2) (NFPA 101 12.2.6) <br />NUMBER OF EXITS: <br />1-500 OCCUPANTS: <br />2 EXITS REQUIRED <br />501-1,000 OCCUPANTS: <br />3 EXITS REQUIRED <br />MORE THAN 1,000 OCCUPANTS: <br />4 EXITS REQUIRED <br />TOTAL OCCUPANT LOAD: <br />SEE LIFE SAFETY PLAN <br />SURFACE MOUNTED FIRE EXTINGUISHERS TO BE <br />PROVIDED IN EACH SUITE <br />[PER NFPA 13] <br />EGRESS WIDTH: <br />SEE LIFE SAFETY PLAN <br />FLORIDA BUILDING PRODUCTS APPROVALS <br />• LANDLORD ROOFING: <br />CONFIRM WITH LANDLORD. USE SAME SYSTEM AND PRODUCT. <br />USE LANDLORD'S CONTRACTOR FOR ALL PATCH/REPAIR. <br />• ROOFING: <br />FIRESTONE, ULTRAPLY TPO <br />FLORIDA APPROVAL NUMBER FL10264-R12 SYSTEM SC-92 <br />• ALUM. WINDOWS: <br />KAWNEER 2250 IG IMPACT CURTAINWALL <br />FLORIDA APPROVAL NUMBER 9924.1 <br />• ALUM. DOORS: <br />KAWNEER 350 <br />FLORIDA APPROVAL NUMBER 10388.1 <br />• H.M. DOORS: <br />CECO DOOR PRODUCTS, SEVERE WINDSTORM RESISTANT DOOR AND FRAME <br />FLORIDA APPROVAL NUMBER 4553-R10 <br />• GLASS BLOCK: <br />SEVES GLASS BLOCK (FORMERLY PITTSBURGH CORNING GLASS BLOCK), <br />THICKSET 90 SERIES GLASS BLOCK WITH KWIK'N'EZ SILICONE SYSTEM. <br />FLORIDA APPROVAL NUMBER 5357.1 <br />• E.I.F.S.: <br />STOTHERM CI SYSTEM <br />FLORIDA APPROVAL NUMBER 20110.1 <br />• SIDING: <br />MAYNE COATINGS, LONGBOARD 6° 'V' GROOVE ALUMINUM SIDING. <br />NO FLORIDA APPROVAL NUMBER. SEE ATTACHED ENGINEER'S LETTER. <br />NOTE: IF CONTRACTOR <br />SUBSTITUTES ALTERNATE PRODUCTS DURING BIDDING OR CONSTRUCTION, SAID <br />SUBSITUTITION MUST INCLUDE A FLORIDA APPROVAL NUMBER AND SHALL BE SUBMITTED TO THE AUTHORITY <br />HAVING JURISDICTION FOR REVIEW AND APPROVAL PRIOR TO PROCEEDING WITH THE WORK. <br />NOTE: IF CONTRACTOR SUBSTITUTES ALTERNATE PRODUCTS DURING BIDDING OR CONSTRUCTION, SAID <br />SUBSITUTITION MUST INCLUDE A FLORIDA APPROVAL NUMBER AND SHALL BE SUBMITTED TO THE AUTHORITY <br />HAVING JURISDICTION FOR REVIEW AND APPROVAL PRIOR TO PROCEEDING WITH THE WORK, <br />PROJECT DESCRIPTION <br />MARKET AT ZEP11yR111LLS <br />1 <br />REVIEW DATE <br />CITY OF ZpH ILS <br />BUILDING OFFICIAL �+_ <br />ALL WORK SMALL GMAPLY WITH PREVAILING <br />CODES FLORIDA BUILDIhIO <br />aDE. <br />NATIONAL ELECTRIC CODE, <br />AND THE CITY Or, ZE.P HYRHILLS <br />ORDINANCES <br />SYMBOLS <br />BUILDING 4 I LOT 4 <br />7495 Gall Blvd <br />Zephyrhills, Florida 33541 <br />(Pretty Pond Road d US 301) <br />PERMIT SET <br />LOCATION MAP <br />ZEPHYRHILLS MARKET <br />BLDG 6 SITE <br />TEAM DIRECTORY <br />W <br />a_ <br />Irf <br />LL <br />0 <br />W <br />D <br />U) <br />U) <br />z <br />W <br />0 <br />m <br />V1 <br />"l- <br />W N <br />4- <br />U � <br />O <br />5... LU <br />L <br />Q « <br />Q) <br />p W <br />5... � <br />U <br />W <br />V S <br />a <br />N N N <br />N N N <br />� � <br />O CN O <br />O) CV <br />O O O <br />07 <br />W <br />N <br />z <br />a < <br />E _ <br />E U <br />0 w <br />z <br />c <br />3 O <br />O <br />lcalfm <br />m <br />>1co110 <br />to <br />pY O N <br />O 00 <br />O Q <br />C 730 <br />O <br />V O O <br />O v <br />'- Q) 't <br />U_ <br />C <br />V N <br />J v <br />.- < <br />N Q <br />N <br />C m <br />.- <br />� O <br />m <br />� LL <br />O v <br />� o <br />L <br />w <br />0 <br />LL <br />O >_ H 0 O <br />J W z <br /><WCf) IN—wa- V0 <br />m U= W 0 z O Lbz <br />CL <br />N= W WUj = z LU d O <br />Q U > Z ~ F- <br />=<cW� W-(WOw0E <br />LLI <br />Ix W <br />U afO <br />a—W -Z W=�U <br />OO=WWF-W <br />U_mHUR>=O <br />CO0W�Lo <br />6 <br />(6 <br />C <br />0 <br />.Q <br />U <br />CD <br />CD <br />0 <br />0 <br />z <br />Sheet Name: <br />COVER SHEET <br />Proj #: <br />Issue Date: <br />210316 <br />09/01 /2022 <br />Sheet No.: <br />G-0,1 <br />Drawn By: <br />Checked By: <br />DL <br />DS <br />ISSUED FOR CONSTRUCTION <br />
The URL can be used to link to this page
Your browser does not support the video tag.