My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7495 Gall Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
7495 Gall Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 7:22:55 PM
Creation date
2/18/2025 3:40:09 PM
Metadata
Fields
Template:
Building Plans
Street #
7495
Location
Gall Blvd
Contractor
Schroeder Architects
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
84
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL SHEET NOTES <br />1. NOT ALL ITEMS MAY BE USED. <br />2. DIMENSIONS ARE TAKEN TO FACE OF STUD, FACE OF MASONRY OR <br />CONCRETE , OR COLUMN CENTERLINE, UNLESS INDICATED OTHERWISE. <br />3. PRIOR TO ROUGH -IN AND WALL ENCLOSURE, COORDINATE ALL WORK WITH <br />TENANT/OWNER VENDOR REQUIREMENTS. <br />4. PRIOR TO ROUGH -IN AND WALL ENCLOSURE, COORDINATE LOCATION OF <br />ALL WALL MOUNTED FIXTURES AND DEVICES WITH FINISH WORK SHOWN IN <br />THE ARCHITECTURAL AND/OR ID DRAWINGS - ALIGN AS INDICATED. THIS <br />SHALL INCLUDE, BUT NOT BE LIMITED TO: ALL CONTRACTOR, <br />TENANT/OWNER, AND TENANT/OWNER VENDOR SUPPLIED ITEMS. <br />4.1. IF THERE IS A DISCREPANCY BETWEEN THE ARCHITECTURAL AND ID <br />DRAWINGS, NOTIFY THE ARCHITECT FOR RESOLUTION PRIOR TO <br />PROCEEDING WITH THE WORK. <br />4.2. IF THERE IS A DISCREPANCY WITH THE ACCESSIBILITY STANDARDS, <br />REPORT THE DISCREPANCY TO THE ARCHITECT FOR RESOLUTION <br />PRIOR TO PROCEEDING WITH THE WORK. <br />5. PRIOR TO WALL ENCLOSURE, CONTRACTOR SHALL PROVIDE ALL BLOCKING <br />AS REQUIRED FOR WALL MOUNTED ITEMS. THIS SHALL INCLUDE, BUT <br />NOT BE LIMITED TO: ALL CONTRACTOR, TENANT/OWNER, AND <br />TENANT/OWNER VENDOR SUPPLIED ITEMS. <br />5.1. COORDINATE FINAL LOCATIONS OF OWNER AND THIRD PARTY VENDOR <br />FURNISHED ITEMS IN THE FIELD WITH TENANT/OWNER REP AND THE <br />VENDOR. <br />5.2. UNLESS INDICATED OTHERWISE, ALL BLOCKING SHALL BE ENCLOSED <br />INSIDE FINISH CONSTRUCTION. <br />5.3. BLOCKING AT DRY LOCATIONS: FIRE RETARDANT TREATED WOOD <br />BLOCKING. <br />5.4. BLOCKING AT WET LOCATIONS: GALVANIZED METAL STRAP BLOCKING, <br />AS PROVIDED BY METAL STUD SUPPLIER/FABRICATOR. <br />6. CONTRACTOR SHALL PROVIDE ALL NECESSARY FRAMING TO ACCOMMODATE <br />THE FINAL LAYOUTS SHOWN FOR ALL FINISHES SHOWN IN THE <br />ARCHITECTURAL AND ID DRAWINGS. <br />7. ALL FIRE RATED PARTITIONS SHALL BE EFFECTIVELY AND PERMANENTLY <br />IDENTIFIED WITH SIGNS OR STENCILING. SUCH IDENTIFICATION SHALL BE <br />ABOVE ANY DECORATIVE CEILING AND IN CONCEALED SPACES. IDENTIFY <br />WITH THE FOLLOWING TEXT: 'XX' HOUR RATED FIRE/SMOKE BARRIER. <br />PROTECT ALL OPENINGS AND PENETRATIONS. CONFIRM HOURLY RATING <br />WITH WITH FIRE RESISTANCE RATING OF WALL. AT LOCATIONS WHERE <br />THERE ARE NO CEILINGS OR CONCEALED SPACES, COORDINATE SIGNAGE <br />REQUIREMENT WITH THE AUTHORITY HAVING JURISDICTION (AHJ). AT THESE <br />LOCATIONS, IF SIGNAGE IS REQUIRED BY THE AHJ, CONFIRM WITH <br />TENANT/OWNER IF THEY PREFER SIGNS OR STENCILING. <br />LEGEND <br />MATCH LINE LOCATION <br />_ _ _ _ _ _ - 0.5-HOUR RATED WALL CONSTRUCTION LOCATION <br />.. s .... 1-HOUR RATED WALL CONSTRUCTION LOCATION <br />2-HOUR RATED WALL CONSTRUCTION LOCATION <br />3-HOUR RATED WALL CONSTRUCTION LOCATION <br />4-HOUR RATED WALL CONSTRUCTION LOCATION <br />GRAPHIC ... LARGE WALL GRAPHIC LOCATION <br />MIRROR .... LARGE WALL MIRROR LOCATION <br />WALL MOUNTED FIRE EXTINGUISHER AND BRACKET <br />LOCATION. SEE XX/XXX. <br />RECESSED/SEMI-RECESSED FIRE EXTINGUISHER AND <br />u CABINET LOCATION. SEE XX/XXX. <br />SURFACE MOUNT FIRE EXTINGUISHER AND CABINET <br />m LOCATION. SEE XX/XXX. <br />SURFACE MOUNT DEFIBRILATOR AND CABINET LCOATION. <br />I� SEE XX/XXX. <br />KEYNOTES <br />1. PROPOSED FIRE DEPARTMENT KNOX BOX LOCATION. CONFIRM FINAL <br />LOCATION WITH THE LOCAL AUTHORITY HAVING JURISDICTION. <br />2. FIRE RISER IS LOCATED IN THIS ROOM. COORDINATE WITH PLUMBING <br />AND FINAL FIRE SUPPRESSION DOCUMENTS PREPARED BY THE FIRE <br />SUPPRESSION CONTRACTOR. <br />3. ELECTRICAL SERVICE, SWITCHGEAR, AND TRANSFORMER ARE LOCATED IN <br />THIS ROOM. COORDINATE WITH THE ELECTRICAL. <br />4. ELECTRICAL STUB -UP LOCATION. <br />5. ROOF HATCH LADDER LOCATION. SEE DETAIL XX/XXX. <br />EDGE OF SLAB PLAN <br />1/8"=1'-0" <br />M� <br />3mN <br />M <br />to <br />a d N <br />ZU` <br />00 <br />i. M M <br />w <br />d 4 <br />O <br />C n <br />o0 <br />z <br />�= <br />v0o <br />m <br />O u <br />'- <br />2 <br />LL <br />c: <br />CL <br />^' <br />w <br />» <br />L <br />< <br />=3 <br />o <br />Vo <br />x <br />LL <br />Q <br />ov <br />� o <br />L <br />= <br />N <br />W <br />» <br />2 <br />Q) <br />o <br />0 <br />W <br />L <br />p <br />iU <br />V <br />W <br />d <br />N <br />Q <br />a <br />LL <br />J O <br />°W<Wz <br />QuWjF�- waVOai <br />} U W Z a- C) W <br />m01-2IX'zOV%z <br />oILU ---D� W za�0 <br />N= W PT<wwF-. <br />OQ W W W_z z W O <br />_W- <br />- <br />OWZw<1LUWWcru)W <br />d co) � U <br />WF-zO <br />W 53:U <br />O O= LL W Q LU W <br />0=C72>=m0F=- <br />r <br />U�0LUU_ <br />H <br />0 <br />a <br />N <br />N <br />O <br />N <br />`O <br />CD <br />12 <br />W <br />a <br />O <br />W <br />07 <br />B <br />19 <br />Sheet Name: <br />EDGE OF SLAB PLAN <br />Proj #: <br />issue Date: <br />210316 <br />09/01 /2022 <br />Sheet No.: <br />A-0. I <br />Drawn By: <br />Checked By: <br />DL <br />DS <br />ISSUED FOR CONSTRUCTION <br />
The URL can be used to link to this page
Your browser does not support the video tag.