My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7495 Gall Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
7495 Gall Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 7:22:55 PM
Creation date
2/18/2025 3:40:09 PM
Metadata
Fields
Template:
Building Plans
Street #
7495
Location
Gall Blvd
Contractor
Schroeder Architects
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
84
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2/A-4.1 <br />N <br />CV <br />FLOOR PLAN <br />3116"=1'-0" <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />11 <br />12 <br />13 <br />14 <br />15 <br />16 <br />17 <br />18 <br />19 <br />20 <br />21 <br />22 <br />23 <br />KEYNOTES <br />SLAB LEAVE -OUT FOR FUTURE TENANT U/G UTILITIES. PROVIDE HARDCORE BASE <br />AND VAPOR BARRIER. <br />RATED DEMISING WALL. REFER TO PARTITION SCHEDULE <br />SANITARY SEWER LATERAL - STUB INTO BUILDING AND CAP FOR FUTURE <br />CONNECTION - SEE CIVIL AND PLUMBING DWGS. <br />ELECTRICAL METER BANK - SEE ELECTRICAL DWGS. <br />TELEPHONE BOARD FOR FUTURE TENANT USE. PROVIDE CONDUIT & PULL <br />STRING. FIANL LOCATION T.B.D. - SEE ELECTRICAL DWGS. <br />GAS HEADER - RUN TO ROOF TOP UNIT & STUB INTO BUILDING AND CAP FOR <br />FUTURE CONNECTION - SEE PLUMBING DWGS. <br />APPROX. LOCATION OF RTU ABOVE. REFER TO ROOF PLAN & MECH. DRAWINGS <br />STOREFRONT SYSTEM WITH LOW-E INSULATED GLAZING - SEE WALL SECTIONS <br />AND ELEVATIONS <br />LINE OF AWNING OR CANOPY ABOVE - SEE WALL SECTIONS AND ELEVATIONS <br />4" CONCRETE SIDEWALK WITH EXPANSION JOINTS AND SCORE JOINTS AS SHOWN <br />ON SIDEWALK PLANS. SLOPE SIDEWALK AWAY FROM STOREFRONT AT 1:50 MAX. <br />UNLESS OTHERWISE NOTED ON SPOT ELEVATIONS. SEE GEOTECHNICAL REPORT <br />FOR SUB -BASE REQUIREMENTS. SEE CIVIL DWGS. <br />NON -FREEZE HOSE BIBB MOUNTED AT 18" ABOVE EXTERIOR GRADES/SIDEWALK <br />- SEE PLUMBING DWGS. <br />STOREFRONT DOOR, TYP. - SEE DOOR SCHEDULE. HOLLOW METAL DOOR, TYP. <br />- SEE DOOR SCHEDULE <br />DOMESTIC WATER PER LLWL REQUIREMENTS. STUB BELOW ROOF DECKING FOR <br />FUTRE TENANT CONNECTION. SEE PLUMBING DWGS. <br />JUNCTION BOX ON FACADE FOR FUTURE SIGNAGE BY TENANT. SIGNAGE <br />PERMITTED BY OTHERS - SEE ELEVATIONS. CENTER ABOVE STOREFRONTS ON <br />SIGNAGE BAND ZONE <br />ROOF LADDER - SEE ROOF PLAN <br />STRUCTURAL STEEL COLUMN - SEE STRUCTURAL DWGS. <br />DEPRESSED CURB WITH RAISED ADA DETECTABLE WARNING STRIP - SEE CIVIL <br />DWGS. <br />FLOOR DRAIN - SEE PLUMBING DWGS. <br />DECORATIVE (C-CHANNEL) STEEL FRAME <br />ROOF DRAINAGE DOWNSPOUT. TIE INTO STORM, TYP. SEE CIVIL DWGS. SEE ROOF <br />PLAN FOR DOWNSPOUT SIZE AND CONFIGURATION. SEE PLUMBING DWGS. FOR <br />ROOF DRAIN PIPING. <br />LIGHT FIXTURE WHERE SHOWN. REFER TO LUMINAIRE SCHEDULE <br />LIGHT FIXTURE: WALL PACK <br />KNOX BOX. FIRE MARSHAL. FINAL LOCATION BY FIRE MARSHAL. <br />24 TRANSFORMER AND CONCRETE PAD - SEE ELECTRICAL & CIVIL DWGS. FOR <br />LOCATION. <br />25 HOUSE PANEL - SEE ELECTRICAL DWGS. <br />26 <br />27 <br />28 <br />29 <br />30 <br />31 <br />32 <br />33 <br />34 <br />35 <br />36 <br />HOUSE PANEL - ALARM <br />WHEEL STOPS - REFER TO CIVIL <br />GREASE TRAPS AS REQUIRED BY LOCAL HEALTH DEPT./UTILITIES. TOP OF <br />MANHOLE COVERS TO BE FLUSH W/ ADJACENT SURFACE - TO BE SIZED BY <br />CIVIL ENGINEER. COORDINATE FINAL LOCATION W/ CIVIL DWGS. <br />GREASE WASTE LINE - STUB INTO BUILDING AND CAP FOR FUTURE CONNECTION <br />- SEE CIVIL AND PLUMBING DWGS. <br />DRIVE-THRU SERVICE WINDOW - PENDING TENANT'S SPECS <br />PATIO PAVERS & AREA REFER TO LANDSCAPING FINISH SCHEDULE <br />PROVIDE CONNECTION TO STORM LATERAL FROM THIS AREA <br />PROVIDE W/P JUNCTION BOX FOR TENANT POLE LIGHT <br />PROVIDE MINERAL FIBER SOUND ATTENUATION INSULATION IN DEMISING WALL <br />PROVIDE TROWELED SMOOTH STEEL REINFORCED CONCRETE SLAB WITHOUT <br />ELEVATION CHANGES. NO MORE THAN 1/8" ELEVATION CHANGE IN 10'-0" AND <br />MUST MEET OR EXCEED ASTM F1869-98 MOISTURE VAPOR EMISSIONS <br />GUIDELINES OF LESS THAN 5 POUNDS OF MOISTURE OVER 1,000 SQUARE FEET <br />WITHIN A 24-HOUR PERIOD <br />GAS MANIFOLD & METER LOCATION - REFER TO CIVIL & PLUMBING <br />CONCRETE FILLED STEEL PIPE BOLLARDS. MIN 4" DIA <br />REFLECTED CEILING NOTES <br />40 EXPOSED UNDERSIDE OF ROOF DECK <br />41 ROOF JOISTS/BEAMS - REFER TO STRUCTURAL <br />42 LINE OF ROOF OR PARAPET RETURN ABOVE <br />43 LOW PROFILE (PUCK) LIGHTS BELOW CANOPY <br />ROOF NOTES <br />50 APPROX. LINE OF STRUCTURE BELOW. FINAL RTU LOCATION TO BE CONFIRMED IN <br />THE FIELD <br />51 EXTERIOR ROOF LADDER & CAGE AS REQUIRED BY CODE OR AHJ. <br />52 ROOF WALKING PADS <br />53 AREA OF TAPERED INSULATION/CRICKETS TO INSTALLED OVER BASE ROOF <br />INSULATION. SLOPE AS INDICATED ON DRAWING. MINIMUM 1/2":12 <br />54 PRE -FINISHED METAL CANOPY BELOW <br />55 HIGH PARAPET. REFER TO SECTIONS AND STRUCTURAL <br />56 <br />57 THRU WALL SCUPPER INTO CONDUCTOR HEAD TO ROOF DRAIN <br />58 SCUPPER OVERFLOW. REFER TO DETAIL. <br />59 DEMISING TENANT WALL BELOW. <br />SIDIM HARDSCAPE NOTES <br />60 CONTROL JOINTS AS SHOWN. 1/4" SAWCUTS TYPICAL <br />61 PLANTER BEDS. FINALS SIZE & CONFIGURATION BY CIVIL & LANDSCAPING <br />62 ADA CURB & SIDEWALX RAMP(S). REFER TO CIVIL FOR DETAILS <br />63 ZERO CURB. PROVIDE PROTECTIVE BOLLARDS AT STOREFRONTS <br />64 EXPANSION JOINTS. CIVIL TO CONFIRM <br />65 FLOOR DRAIN - SEE PLUMBING DWGS. <br />66 4" CONCRETE SIDEWALK WITH EXPANSION JOINTS AND SCORE JOINTS AS SHOWN <br />ON SIDEWALK PLANS. SLOPE SIDEWALK AWAY FROM STOREFRONT AT 1:50 MAX. <br />UNLESS OTHERWISE NOTED ON SPOT ELEVATIONS. SEE GEOTECHNICAL REPORT <br />FOR SUB -BASE REQUIREMENTS. SEE CIVIL DWGS. <br />67 GREASE TRAPS AS REQUIRED BY LOCAL HEALTH DEPT./UTILITIES. TOP OF <br />MANHOLE COVERS TO BE FLUSH W/ ADJACENT SURFACE - TO BE SIZED BY <br />CIVIL ENGINEER. COORDINATE FINAL LOCATION W/ CIVIL DWGS. <br />68 PATIO PAVERS & AREA REFER TO LANDSCAPING FINISH SCHEDULE <br />PROVIDE CONNECTION TO STORM LATERAL FROM THIS AREA <br />69 WHEEL STOPS - REFER TO CIVIL <br />GENERAL SHEET NOTES <br />1. NOT ALL ITEMS MAY BE USED. <br />2. DIMENSIONS ARE TAKEN TO FACE OF STUD, FACE OF MASONRY OR <br />CONCRETE , OR COLUMN CENTERLINE, UNLESS INDICATED OTHERWISE. <br />3. PRIOR TO ROUGH -IN AND WALL ENCLOSURE, COORDINATE ALL WORK WITH <br />TENANT/OWNER VENDOR REQUIREMENTS. <br />4. PRIOR TO ROUGH -IN AND WALL ENCLOSURE, COORDINATE LOCATION OF <br />ALL WALL MOUNTED FIXTURES AND DEVICES WITH FINISH WORK SHOWN IN <br />THE ARCHITECTURAL AND/OR ID DRAWINGS - ALIGN AS INDICATED. THIS <br />SHALL INCLUDE, BUT NOT BE LIMITED TO: ALL CONTRACTOR, <br />TENANT/OWNER, AND TENANT/OWNER VENDOR SUPPLIED ITEMS. <br />4.1. IF THERE IS A DISCREPANCY BETWEEN THE ARCHITECTURAL AND ID <br />DRAWINGS, NOTIFY THE ARCHITECT FOR RESOLUTION PRIOR TO <br />PROCEEDING WITH THE WORK. <br />4.2. IF THERE IS A DISCREPANCY WITH THE ACCESSIBILITY STANDARDS, <br />REPORT THE DISCREPANCY TO THE ARCHITECT FOR RESOLUTION <br />PRIOR TO PROCEEDING WITH THE WORK. <br />5. PRIOR TO WALL ENCLOSURE, CONTRACTOR SHALL PROVIDE ALL BLOCKING <br />AS REQUIRED FOR WALL MOUNTED ITEMS. THIS SHALL INCLUDE, BUT <br />NOT BE LIMITED TO: ALL CONTRACTOR, TENANT/OWNER, AND <br />TENANT/OWNER VENDOR SUPPLIED ITEMS. <br />5.1. COORDINATE FINAL LOCATIONS OF OWNER AND THIRD PARTY VENDOR <br />FURNISHED ITEMS IN THE FIELD WITH TENANT/OWNER REP AND THE <br />VENDOR. <br />5.2. UNLESS INDICATED OTHERWISE, ALL BLOCKING SHALL BE ENCLOSED <br />INSIDE FINISH CONSTRUCTION. <br />5.3. BLOCKING AT DRY LOCATIONS: FIRE RETARDANT TREATED WOOD <br />BLOCKING. <br />5.4. BLOCKING AT WET LOCATIONS: GALVANIZED METAL STRAP BLOCKING, <br />AS PROVIDED BY METAL STUD SUPPLIER/FABRICATOR. <br />6. CONTRACTOR SHALL PROVIDE ALL NECESSARY FRAMING TO ACCOMMODATE <br />THE FINAL LAYOUTS SHOWN FOR ALL FINISHES SHOWN IN THE <br />ARCHITECTURAL AND ID DRAWINGS. <br />7. ALL FIRE RATED PARTITIONS SHALL BE EFFECTIVELY AND PERMANENTLY <br />IDENTIFIED WITH SIGNS OR STENCILING. SUCH IDENTIFICATION SHALL BE <br />ABOVE ANY DECORATIVE CEILING AND IN CONCEALED SPACES. IDENTIFY <br />WITH THE FOLLOWING TEXT: 'XX' HOUR RATED FIRE/SMOKE BARRIER. <br />PROTECT ALL OPENINGS AND PENETRATIONS. CONFIRM HOURLY RATING <br />WITH WITH FIRE RESISTANCE RATING OF WALL. AT LOCATIONS WHERE <br />THERE ARE NO CEILINGS OR CONCEALED SPACES, COORDINATE SIGNAGE <br />REQUIREMENT WITH THE AUTHORITY HAVING JURISDICTION (AHJ). AT THESE <br />LOCATIONS, IF SIGNAGE IS REQUIRED BY THE AHJ, CONFIRM WITH <br />TENANT/OWNER IF THEY PREFER SIGNS OR STENCILING. <br />LEGEND <br />® <br />MATCH LINE LOCATION <br />0.5-HOUR RATED WALL CONSTRUCTION LOCATION <br />— _ — _ — _ — <br />1-HOUR RATED WALL CONSTRUCTION LOCATION <br />2-HOUR RATED WALL CONSTRUCTION LOCATION <br />3-HOUR RATED WALL CONSTRUCTION LOCATION <br />4-HOUR RATED WALL CONSTRUCTION LOCATION <br />GRAPHIC <br />LARGE WALL GRAPHIC LOCATION <br />MIRROR ... _ .... <br />LARGE WALL MIRROR LOCATION <br />WALL MOUNTED FIRE EXTINGUISHER AND BRACKET <br />a <br />LOCATION. SEE XX/XXX. <br />RECESSED/SEMI-RECESSED FIRE EXTINGUISHER AND <br />r� <br />CABINET LOCATION. SEE XX/XXX. <br />SURFACE MOUNT FIRE EXTINGUISHER AND CABINET <br />m <br />LOCATION. SEE XX/XXX. <br />SURFACE MOUNT DEFIBRILATOR AND CABINET LCCATION. <br />SEE XX/XXX. <br />KEYNOTES <br />1. PROPOSED FIRE DEPARTMENT KNOX BOX LOCATION. CONFIRM FINAL <br />LOCATION WITH THE LOCAL AUTHORITY HAVING JURISDICTION. <br />2. FIRE RISER IS LOCATED IN THIS ROOM. COORDINATE WITH PLUMBING <br />AND FINAL FIRE SUPPRESSION DOCUMENTS PREPARED BY THE FIRE <br />SUPPRESSION CONTRACTOR. <br />3. ELECTRICAL SERVICE, SWITCHGEAR, AND TRANSFORMER ARE LOCATED IN <br />THIS ROOM. COORDINATE WITH THE ELECTRICAL. <br />4. ELECTRICAL STUB -UP LOCATION. <br />5. ROOF HATCH LADDER LOCATION. SEE DETAIL XX/XXX. <br />M[Y I <br />> co <br />M <br />M N <br />M \0 <br />\'C' <br />Ln <br />p. O N <br />O g <br />L M M <br />0 � <br />4 <br />i� c6 M <br />'to <br />0 <br />O v <br />°' <br />\10 <br />U 00 <br />0 <br />d <br />L NUL <br />v16 <br />C� <br />Wes) <br />�Q <br />W <br />n <br />4 <br />H L <br />� Q <br />N <br />=3 o <br />M <br />LL <br />ra <br />L '6 <br />O <br />o <br />W <br />0 <br />LL LL <br />Qu W�0 <br />aVOOZ <br />wZ0-Op5nw <br />m U f of z 0 Z <br />oHOwwzmwLU o <br />Vjrj � d= <br />of 0 <br />0_LU Z <br />�M: 0P <br />0000�� <br />N <br />N <br />O <br />N <br />0 <br />rn <br />0 <br />i <br />is <br />0 <br />6 <br />z <br />Sheet Name: <br />FLOOR PLAN <br />Prol #: <br />Issue Date: <br />210316 <br />09/01 /2022 <br />Sheet No.: <br />A-101 <br />Drawn By: <br />Checked By: <br />DL <br />DS <br />- <br />ISSUED FOR CONSTRUCTION <br />
The URL can be used to link to this page
Your browser does not support the video tag.