sia1V190" <br />—i <br />GENERAL SHEET NOTES <br />1. NOT ALL ITEMS MAY BE USED. <br />2. DIMENSIONS ARE TAKEN TO FACE OF STUD, FACE OF MASONRY OR CONCRETE , OR COLUMN CENTERLINE, UNLESS INDICATED OTHERWISE. <br />3. PRIOR TO ROUGH -IN AND WALL ENCLOSURE, COORDINATE ALL WORK WITH TENANT/OWNER VENDOR REQUIREMENTS. <br />4. PRIOR TO ROUGH -IN AND WALL ENCLOSURE, COORDINATE LOCATION OF ALL WALL MOUNTED FIXTURES AND DEVICES WITH FINISH WORK SHOWN IN THE <br />ARCHITECTURAL AND/OR ID DRAWINGS - ALIGN AS INDICATED. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO: ALL CONTRACTOR, TENANT/OWNER, AND <br />TENANT/OWNER VENDOR SUPPLIED ITEMS. <br />4.1. IF THERE IS A DISCREPANCY BETWEEN THE ARCHITECTURAL AND ID DRAWINGS, NOTIFY THE ARCHITECT FOR RESOLUTION PRIOR TO PROCEEDING <br />WITH THE WORK. <br />4.2. IF THERE IS A DISCREPANCY WITH THE ACCESSIBILITY STANDARDS, REPORT THE DISCREPANCY TO THE ARCHITECT FOR RESOLUTION PRIOR TO <br />PROCEEDING WITH THE WORK. <br />5. PRIOR TO WALL ENCLOSURE, CONTRACTOR SHALL PROVIDE ALL BLOCKING AS REQUIRED FOR WALL MOUNTED ITEMS. THIS SHALL INCLUDE, BUT NOT BE <br />LIMITED TO: ALL CONTRACTOR, TENANT/OWNER, AND TENANT/OWNER VENDOR SUPPLIED ITEMS. <br />5.1. COORDINATE FINAL LOCATIONS OF OWNER AND THIRD PARTY VENDOR FURNISHED ITEMS IN THE FIELD WITH TENANT/OWNER REP AND THE VENDOR. <br />5.2. UNLESS INDICATED OTHERWISE, ALL BLOCKING SHALL BE ENCLOSED INSIDE FINISH CONSTRUCTION. <br />5.3. BLOCKING AT DRY LOCATIONS: FIRE RETARDANT TREATED WOOD BLOCKING. <br />5.4. BLOCKING AT WET LOCATIONS: GALVANIZED METAL STRAP BLOCKING, AS PROVIDED BY METAL STUD SUPPLIER/FABRICATOR. <br />6. CONTRACTOR SHALL PROVIDE ALL NECESSARY FRAMING TO ACCOMMODATE THE FINAL LAYOUTS SHOWN FOR ALL FINISHES SHOWN IN THE ARCHITECTURAL <br />AND ID DRAWINGS. <br />7. ALL FIRE RATED PARTITIONS SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING. SUCH IDENTIFICATION SHALL BE ABOVE <br />ANY DECORATIVE CEILING AND IN CONCEALED SPACES. IDENTIFY WITH THE FOLLOWING TEXT. 'XX' HOUR RATED FIRE/SMOKE BARRIER. PROTECT ALL <br />OPENINGS AND PENETRATIONS. CONFIRM HOURLY RATING WITH WITH FIRE RESISTANCE RATING OF WALL. AT LOCATIONS WHERE THERE ARE NO <br />CEILINGS OR CONCEALED SPACES, COORDINATE SIGNAGE REQUIREMENT WITH THE AUTHORITY HAVING JURISDICTION (AHJ). AT THESE LOCATIONS, IF <br />SIGNAGE IS REQUIRED BY THE AHJ, CONFIRM WITH TENANT/OWNER IF THEY PREFER SIGNS OR STENCILING. <br />KEYNOTES <br />1 SLAB LEAVE -OUT FOR FUTURE TENANT U/G UTILITIES. PROVIDE HARDCORE BASE <br />AND VAPOR BARRIER. <br />2 RATED DEMISING WALL. REFER TO PARTITION SCHEDULE <br />3 SANITARY SEWER LATERAL - STUB INTO BUILDING AND CAP FOR FUTURE <br />CONNECTION - SEE CIVIL AND PLUMBING DWGS. <br />4 ELECTRICAL METER BANK - SEE ELECTRICAL DWGS. <br />5 TELEPHONE BOARD FOR FUTURE TENANT USE. PROVIDE CONDUIT & PULL <br />STRING. FIANL LOCATION T.B.D. - SEE ELECTRICAL DWGS. <br />6 GAS HEADER - RUN TO ROOF TOP UNIT & STUB INTO BUILDING AND CAP FOR <br />FUTURE CONNECTION - SEE PLUMBING DWGS. <br />7 APPROX. LOCATION OF RTU ABOVE. REFER TO ROOF PLAN & MECH. DRAWINGS <br />8 STOREFRONT SYSTEM WITH LOW-E INSULATED GLAZING - SEE WALL SEC11ONS <br />AND ELEVATIONS <br />9 LINE OF AWNING OR CANOPY ABOVE - SEE WALL SECTIONS AND ELEVATIONS <br />10 4" CONCRETE SIDEWALK WITH EXPANSION JOINTS AND SCORE JOINTS AS SHOWN <br />ON SIDEWALK PLANS. SLOPE SIDEWALK AWAY FROM STOREFRONT AT 1:50 MAX. <br />UNLESS OTHERWISE NOTED ON SPOT ELEVATIONS. SEE GEOTECHNICAL REPORT <br />FOR SUB —BASE REQUIREMENTS. SEE CIVIL DWGS. <br />11 NON —FREEZE HOSE BIBB MOUNTED AT 18" ABOVE EXTERIOR GRADES/SIDEWALK <br />- SEE PLUMBING DWGS. <br />12 STOREFRONT DOOR, TYP. - SEE DOOR SCHEDULE. HOLLOW METAL DOOR, TYP. <br />- SEE DOOR SCHEDULE <br />13 DOMESTIC WATER PER LLWL REQUIREMENTS. STUB BELOW ROOF DECKING FOR <br />FUTRE TENANT CONNECTION. SEE PLUMBING DWGS. <br />14 JUNCTION BOX ON FACADE FOR FUTURE SIGNAGE BY TENANT. SIGNAGE <br />PERMITTED BY OTHERS - SEE ELEVATIONS. CENTER ABOVE STOREFRONTS ON <br />SIGNAGE BAND ZONE <br />15 ROOF LADDER - SEE ROOF PLAN <br />16 STRUCTURAL STEEL COLUMN - SEE STRUCTURAL DWGS. <br />17 DEPRESSED CURB WITH RAISED ADA DETECTABLE WARNING STRIP - SEE CIVIL <br />DWGS. <br />18 FLOOR DRAIN - SEE PLUMBING DWGS. <br />19 DECORATIVE (C-CHANNEL) STEEL FRAME <br />20 ROOF DRAINAGE DOWNSPOUT. TIE INTO STORM, TYP. SEE CIVIL DWGS. SEE ROOF <br />PLAN FOR DOWNSPOUT SIZE AND CONFIGURATION. SEE PLUMBING DWGS. FOR <br />ROOF DRAIN PIPING. <br />21 LIGHT FIXTURE WHERE SHOWN. REFER TO LUMINAIRE SCHEDULE <br />22 LIGHT FIXTURE: WALL PACK <br />23 KNOX BOX. FIRE MARSHAL FINAL LOCATION BY FIRE MARSHAL. <br />24 TRANSFORMER AND CONCRETE PAD - SEE ELECTRICAL & CIVIL DWGS. FOR <br />LOCATION. <br />25 HOUSE PANEL - SEE ELECTRICAL DWGS. <br />26 HOUSE PANEL - ALARM <br />27 WHEEL STOPS - REFER TO CIVIL <br />28 GREASE TRAPS AS REQUIRED BY LOCAL HEALTH DEPT./UTILITIES. TOP OF <br />MANHOLE COVERS TO BE FLUSH W/ ADJACENT SURFACE - TO BE SIZED BY <br />CIVIL ENGINEER. COORDINATE FINAL LOCATION W/ CIVIL DWGS. <br />29 GREASE WASTE LINE - STUB INTO BUILDING AND CAP FOR FUTURE CONNECTION <br />- SEE CIVIL AND PLUMBING DWGS. <br />30 DRIVE-THRU SERVICE WINDOW - PENDING TENANT'S SPECS <br />31 PATIO PAVERS & AREA REFER TO LANDSCAPING FINISH SCHEDULE <br />PROVIDE CONNECTION TO STORM LATERAL FROM THIS AREA <br />32 PROVIDE W/P JUNCTION BOX FOR TENANT POLE LIGHT <br />33 PROVIDE MINERAL FIBER SOUND ATTENUATION INSULATION IN DEMISING WALL <br />34 PROVIDE TROWELED SMOOTH STEEL REINFORCED CONCRETE SLAB WITHOUT <br />ELEVATION CHANGES. NO MORE THAN 1/8" ELEVATION CHANGE IN 10'-0" AND <br />MUST MEET OR EXCEED ASTM F1869-98 MOISTURE VAPOR EMISSIONS <br />GUIDELINES OF LESS THAN 5 POUNDS OF MOISTURE OVER 1,000 SQUARE FEET <br />WITHIN A 24-HOUR PERIOD <br />35 GAS MANIFOLD & METER LOCATION - REFER TO CIVIL & PLUMBING <br />LEGEND <br />— _ _ _ _ _ — 0.5—HOUR RATED WALL CONSTRUCTION LOCATION <br />—.—.—_— 1—HOUR RATED WALL CONSTRUCTION LOCATION <br />2—HOUR RATED WALL CONSTRUCTION LOCATION <br />—... 3—HOUR RATED WALL CONSTRUCTION LOCATION <br />—....—....— 4—HOUR RATED WALL CONSTRUCTION LOCATION <br />GRAPHIC LARGE WALL GRAPHIC LOCATION <br />MIRROR _ LARGE WALL MIRROR LOCATION <br />WALL MOUNTED FIRE EXTINGUISHER AND BRACKET LOCATION. SEE <br />ti XX/XXX. <br />RECESSED/SEMI—RECESSED FIRE EXTINGUISHER AND CABINET LOCATION. <br />�t SEE XX/XXX. <br />SURFACE MOUNT FIRE EXTINGUISHER AND CABINET LOCATION. SEE <br />m XX/XXX. <br />O SURFACE MOUNT DEFIBRILATOR AND CABINET LCOATION. SEE XX/XXX. <br />N <br />N <br />0 <br />CV <br />0 <br />0 <br />st <br />D <br />Pr <br />2 <br />st <br />Di <br />D <br />It a <br />ran N <br />N1 <br />rn %O <br />L!) <br />n O N <br />O O <br />i" M m <br />LZ7 <br />UJ <br />Q < <br />fn <br />cow <br />C '&) <br />z <br />O w <br />voo <br />m <br />�� <br />O V <br />L a <br />x <br />Ll.. <br />ai <br />E <br />1 <br />N c0 <br />a � <br />m <br />-� <br />V <br />it <br />a <br />o <br />u- <br />v <br />Q <br />o a <br />L <br />L <br />V <br />W <br />N <br />W <br />N <br />vo <br />Q) <br />> <br />o <br />O <br />w <br />iw <br />V <br />x <br />N <br />O <br />a <br />N <br />Q <br />0 <br />