My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7495 Gall Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
7495 Gall Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 7:22:55 PM
Creation date
2/18/2025 3:40:09 PM
Metadata
Fields
Template:
Building Plans
Street #
7495
Location
Gall Blvd
Contractor
Schroeder Architects
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
84
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FIRST FLOOR REFLECTED CEILING PLAN <br />1/8"=l'-0" <br />GENERAL SHEET NOTES <br />1. NOT ALL ITEMS MAY BE USED. <br />2. DIMENSIONS ARE TAKEN TO FACE OF STUD, FACE OF MASONRY OR <br />CONCRETE , CENTERLINE OF LIGHT FIXTURE, OR COLUMN CENTERLINE, <br />UNLESS INDICATED OTHERWISE. <br />3. PRIOR TO ROUGH —IN AND CEILING ENCLOSURE, COORDINATE ALL WORK <br />WITH TENANT/OWNER VENDOR REQUIREMENTS. <br />4. PRIOR TO ROUGH —IN AND CEILING ENCLOSURE, COORDINATE LOCATION OF <br />ALL WALL MOUNTED FIXTURES AND DEVICES WITH FINISH WORK SHOWN IN <br />THE ARCHITECTURAL AND/OR ID DRAWINGS — ALIGN AS INDICATED. THIS <br />SHALL INCLUDE, BUT NOT BE LIMITED TO: ALL CONTRACTOR, <br />TENANT/OWNER, AND TENANT/OWNER VENDOR SUPPLIED ITEMS. <br />4.1. IF THERE IS A DISCREPANCY BETWEEN THE ARCHITECTURAL AND ID <br />DRAWINGS, NOTIFY THE ARCHITECT FOR RESOLUTION PRIOR TO <br />PROCEEDING WITH THE WORK. <br />4.2. IF THERE IS A DISCREPANCY WITH THE ACCESSIBILITY STANDARDS, <br />REPORT THE DISCREPANCY TO THE ARCHITECT FOR RESOLUTION <br />PRIOR TO PROCEEDING WITH THE WORK. <br />5. PRIOR TO CEILING ENCLOSURE, CONTRACTOR SHALL PROVIDE ALL <br />BLOCKING AND/OR SUPPORT AS REQUIRED FOR WALL MOUNTED ITEMS. <br />THIS SHALL INCLUDE, BUT NOT BE LIMITED TO: ALL CONTRACTOR, <br />TENANT/OWNER, AND TENANT/OWNER VENDOR SUPPLIED ITEMS. <br />5.1. COORDINATE FINAL LOCATIONS OF TENANT/OWNER AND THIRD PARTY <br />VENDOR FURNISHED ITEMS IN THE FIELD WITH TENANT/OWNER REP <br />AND THE VENDOR. <br />5.2. UNLESS INDICATED OTHERWISE, ALL BLOCKING SHALL BE ENCLOSED <br />INSIDE FINISH CONSTRUCTION. <br />5.3. BLOCKING AT DRY LOCATIONS: FIRE RETARDANT TREATED WOOD <br />BLOCKING. <br />5.4. BLOCKING AT WET LOCATIONS: GALVANIZED METAL STRAP BLOCKING, <br />AS PROVIDED BY METAL STUD SUPPLIER/FABRICATOR. <br />6. CONTRACTOR SHALL PROVIDE ALL NECESSARY FRAMING TO ACCOMMODATE <br />THE FINAL LAYOUTS SHOWN FOR ALL FINISHES SHOWN IN THE <br />ARCHITECTURAL AND ID DRAWINGS. <br />7. ALL FIRE RATED HORIZONTAL ASSEMBLIES SHALL BE EFFECTIVELY AND <br />PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING. SUCH <br />IDENTIFICATION SHALL BE ABOVE ANY DECORATIVE CEILING AND IN <br />CONCEALED SPACES. IDENTIFY WITH THE FOLLOWING TEXT. 'XX' HOUR <br />RATED FIRE/SMOKE BARRIER. PROTECT ALL OPENINGS AND PENETRATIONS. <br />CONFIRM HOURLY RATING WITH WITH FIRE RESISTANCE RATING OF WALL. <br />AT LOCATIONS WHERE THERE ARE NO CEILINGS OR CONCEALED SPACES, <br />COORDINATE SIGNAGE REQUIREMENT WITH THE AUTHORITY HAVING <br />JURISDICTION (AHJ). AT THESE LOCATIONS, IF SIGNAGE IS REQUIRED BY <br />THE AHJ, CONFIRM WITH TENANT/OWNER IF THEY PREFER SIGNS OR <br />STENCILING. <br />8. CONTRACTOR SHALL COORDINATE CEILING HEIGHTS WITH ALL EQUIPMENT <br />AND DEVICES MOUNTED IN THE CEILING, AS SHOWN IN THE OTHER <br />DISCIPLINE'S DRAWINGS. PRIOR TO THE START OF ALL CEILING WORK, <br />INCLUDING DUCT FABRICATION AND PLUMBING ROUGH —IN, THE <br />CONTRACTOR SHALL PREPARE COORDINATION DRAWINGS FOR REVIEW AND <br />COMMENT. INCLUDE ALL PERTINENT ELEVATION INFORMATION FOR ALL <br />THE DISCIPLINES AND ALL CEILING/SOFFIT HEIGHTS. INDICATE ALL <br />OFFSETS AND TRANSITIONS REQUIRED TO CLEAR STRUCTURAL ELEMENTS. <br />ALL POTENTIAL CONFLICTS WITH CEILING HEIGHTS OR ALIGNMENTS SHALL <br />BE CLOUDED AND NOTED IN THE DOCUMENTS FOR RESOLUTION BY THE <br />ARCHITECT. <br />9. ALL ELECTRICAL AND MECHANICAL ITEMS LOCATED IN ACOUSTICAL CEILING <br />PANELS SHALL BE POSITIONED AT THE MID OR QUARTER POINTS OF THE <br />PANEL. <br />10. ALL LIGHTS, EMERGENCY LIGHTS, STROBES, DIFFUSERS, ETC., SHALL BE <br />CENTERED. ALL STROBES SHALL BE CEILING MOUNTED. <br />11. ALL FIXTURES, CONDUITS, PIPING, DUCTWORK, ETC. SHALL BE MOUNTED <br />AS HIGH AS POSSIBLE TO ENSURE PROPER CLEARANCES AND CEILING <br />HEIGHTS ARE MAINTAINED. CONTRACTOR SHALL LOCATE ALL CONDUITS <br />AND PIPING IN THE JOIST SPACE, AS CLOSE TO THE FLOOR/ROOF DECK <br />ABOVE, TO MAXIMIZE SPACE FOR DUCT INSTALLATION. <br />12. OPEN STRUCTURE CEILING AREAS VISIBLE TO THE PUBLIC, CONTRACTOR <br />SHALL TAKE GREAT CARE TO CAREFULLY LAY OUT ALL UTILITIES/SYSTEMS <br />IN A NEAT AND ORDERLY FASHION, SEE 9/A-7.5 FOR REQUIREMENTS. <br />CONTRACTOR SHALL PROVIDE A MOCK—UP IN THE FIELD OF TYPICAL <br />INSTALLATION CONDITIONS. ACCEPTED MOCK—UP MAY BE PART OF THE <br />FINISH WORK. <br />13. MECHANICAL DIFFUSERS AND GRILLES SHALL BE PREFINISHED IN 'WHITE' <br />TO MATCH THE CEILING TILES. WHERE DIFFUSERS AND GRILLES OCCUR IN <br />PAINTED GYPSUM BOARD SOFFITS, FIELD PAINT THE DIFFUSERS TO MATCH <br />THE SOFFIT COLOR. <br />14. ADDITIONAL DIRECTIONAL EXIT SIGNS MAY BE REQUIRED. CONTRACTOR TO <br />VERIFY QUANTITIES AND LOCATIONS WITH THE LOCAL AUTHORITY HAVING <br />JURISDICTION. <br />15. SEE ELECTRICAL DRAWINGS FOR ALL LIGHT FIXTURE TYPES AND MODELS, <br />16. SEE MECHANICAL DRAWINGS FOR ALL DIFFUSER TYPES AND SIZES. <br />LEGEND <br />ARCHITECTURAL <br />ACT-1 CEILING FINISH TAG. TOP LINE INDICATES MATERIAL TYPE. BOTTOM <br />LINE INDICATES CEILING HEIGHT. <br />ACT1: LAY —IN ACOUSTICAL CEILING 1: 2'x2'. <br />ACT2: LAY —IN ACOUSTICAL CEILING 2: 2'x4'. <br />ACT3: LAY —IN ACOUSTICAL CEILING 4: 2'x4', SECOND LOOK. <br />GB: 5/8° GYPSUM BOARD. <br />MGB: 5/8" MOISTURE RESISTANT GYPSUM BOARD. <br />LP: 5/8" LATHE AND PLASTER. <br />ES: EXPOSED STRUCTURE, PAINTED. <br />EXPOSED STEEL BEAM <br />TILE LAY—INGRID <br />CEILING AND LAY, S CEILING TILE <br />TILE AND GRID o AND GRID, SECOND LOOK <br />2'x4' LAY CEILING GYPSUM BOARD/STUCCO <br />TILE AND GRID CEILING <br />ELECTRICAL <br />1. NOT ALL LIGHT FIXTURES MAY BE USED. <br />2. LIGHTS WITH SUFFIX DESIGNATION 'X' ARE EMERGENCY LIGHT FIXTURES. <br />3. LIGHT FIXTURES WITH SUFFIX DESIGNATION 'D' INDICATE DIMMER CONTROL <br />CONNECTION POINT. <br />4. LIGHT FIXTURES WITH A (*) DESIGNATION ARE COVE MOUNTED LIGHTS. <br />COVES. <br />5. LIGHT FIXTURES WITH A (CW) DESIGNATION ARE MOUNTED IN CASEWORK <br />BELOW. PROVIDED AND INSTALLED BY CASEWORK VENDOR. <br />6. LIGHT FIXTURES WITH A 'WET' DESIGNATION INDICATE TO PROVIDE THE <br />FIXTURE IN A CONFIGURATION APPROVED FOR WET INTERIOR OR EXTERIOR <br />LOCATIONS. <br />® EXIT SIGN EXIT SIGN EMERGENCY <br />WITH ARROW LIGHT <br />RECESSED <br />DOWN LIGHT <br />i = LED TAPE LIGHTS, <br />— SEE ELECTRICAL <br />`-`SERVICE LIGHT <br />KEYNOTES <br />WALLPACK <br />A <br />--g— WALL SCONCES <br />C <br />•a WALL WASH DOWN <br />LIGHT <br />1. SEE ELEVATIONS FOR MOUNTING HEIGHTS OF EXTERIOR LIGHT FIXTURES. <br />2. SEE ELECTRICAL FOR INFORMATION ON TAPE LIGHTS MOUNTED TO <br />DECORATIVE BANDS. <br />3. INTERIOR SOFFIT <br />4. PROVIDE WALLPACK LIGHT OVER REAR DOORS <br />M 0 <br />T OD kO <br />3 M N <br />to <br />p O N <br />z <br />O 0 <br />L M M <br />cn <br />0 < <br />c6 M <br />w <br />00 <br />zz <br />� v <br />U OO <br />L <br />O J <br />+Q) <br />v <br />a) Q) <br />E �— <br />c <br />CU 03 <br />» <br />_1 L <br />— Q <br />N <br />o <br />V <br />it <br />O <br />M LL <br />z <br />ca <br />o v <br />z <br />0o <br />V <br />H <br />� <br />w <br />-� <br />Q) <br />cu <br />o <br />O <br />W <br />z.. <br />U <br />W <br />.c <br />V <br />O <br />N <br />Q <br />0 <br />w <br />0�00 <br />C n w a V O <br />>-W WZaO=p_Ww <br />CD I— p W Z W W 0 <br />N= W� x Q W m= <br />oWW ZZOWZO <br />O W w Q M- 0 F> <br />F-Z aW�z:) <br />0 0 = W W`tWi—w <br />UUlmx <br />�xO1— <br />U�oWoM <br />41 <br />N <br />N <br />O <br />N <br />O <br />CD <br />O <br />W <br />IL <br />ix <br />0 <br />w <br />0 <br />W <br />D <br />rn <br />07 <br />i <br />C6 <br />0 <br />0 <br />Z <br />Sheet Name: <br />REFLECTED CEILING PLAN <br />Proj #: <br />Issue Date: <br />210316 <br />09/01 /2022 <br />Sheet No.: <br />A-104 <br />Drawn By: <br />Checked By: <br />DL <br />DS <br />--- - — _ ...— - -- al. L lu =I i:.HJ', lii.mfi.A t;Al t-111i ➢1 31T. 4JIi,l.i. <br />ISSUED FOR CONSTRUCTION <br />