My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7495 Gall Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
7495 Gall Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 7:22:55 PM
Creation date
2/18/2025 3:40:09 PM
Metadata
Fields
Template:
Building Plans
Street #
7495
Location
Gall Blvd
Contractor
Schroeder Architects
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
84
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2 WEST EXTERIOR ELEVATION <br />A-4.1 1 3/16"=l'-0" <br />1 EAST EXTERIOR ELEVATION <br />-4.1 1 - 3/16"=J'-O" <br />B <br />A Al C <br />I <br />25'-2" 23'-8" 1 <br />SUITE 602 SUITE 601 <br />II I TYP. I v I v I I I <br />14'-2" I I_ 11 13'-4" 1 12'-6" <br />a <br />N <br />1 <br />DECK BRG <br />16'-0" FFL <br />0 <br />I <br />co <br />to <br />1 <br />N <br />rl <br />II II <br />I <br />I� <br />WP WP I WP <br />Ill R ILITY <br />M. SUITE I ( ( \S ITE <br />C)0 ( ( 01 <br />1 <br />o \ II ( I <br />0 <br />I� <br />EF II BR L EF DS L Im <br />�L Z 4 1 <br />HM Cf) W HM <br />BR W Z <br />WEST ELEVATION ® J <br />DECK BRG <br />16'-0" FFL <br />GENERAL SHEET NOTES <br />1. LIGHT FIXTURE DIMENSIONS ARE TAKEN TO CENTERLINE OF THE FIXTURE, UNLESS NOTED OTHERWISE. <br />2. MASONRY/CONCRETE DIMENSIONS ARE TAKEN TO FINISH FACE OF MATERIAL(S). <br />ALL HEIGHTS SHOWN ARE FROM FIRST FLOOR FINISH SLAB ELEVATION. <br />3. GENERAL CONTRACTOR TO VERIFY MOUNTING HEIGHT WRH ARCHITECT PRIOR TO INSTALLATION OF ALL PERIMETER LIGHTING. <br />4. C.J. = CONTROL JOINT. <br />4.1. AT E.IF.S. INSTALL CONTROL JOINT PER MANUFACTURER'S RECOMMENDATION, JOINT SHALL BE 1/r WIDE WffH JOINT SEALANT AND BACKER ROD. <br />4.2. AT THRU-WALL C.M.U. CONTROL JOINTS, PROVIDE 1/2- CLEAR JOINT WITH CONT. INORGANIC CONTROL JOINT GASKET, JOINT SEALANT, AND BACKER <br />ROD. <br />5. AT ALL BUILDING SIGNAGE AND GRAPHIC PANELS OCCURRING AT STUD WALL FRAMING, PROVIDE 5/8- FIRE -TREATED PLYWOOD SHEATHING AS REQUIRED <br />FOR PROPER SIGNAGE AND GRAPHIC PANEL SUPPORT. <br />6. PROVIDE SEALANT AT ALL INTERSECTIONS OF DISSIMILAR MATERIALS. <br />7. 8'-0" x 4W x r MAILABLE EXTERIOR GRADE SHEATHING CENTERED ABOVE DOOR. <br />LEGEND <br />C I J <br />CONTROL JOINT LOCATION <br />E IJ <br />EXPANSION JOINT LOCATION <br />F IJ <br />FALSE JOINT LOCATION <br />(D <br />TEMPERED GLAZING <br />EXTERIOR FINISH SCHEDULE MATERIAL, <br />A � <br />FINISH <br />MATERIAL SCHEDULE <br />SYMBOL <br />DESCRIPTION <br />BR-1 <br />SPLIT -FACE BLOCK MASONRY <br />BR-2 <br />GROUND -FACE BLOCK MASONRY <br />EF-1 <br />EIFS - DRYVIT OR APPROVED ALTERNATE <br />EF-2 <br />WATER TABLE PROFILE. ®FS - DRYVIT OR APPROVED ALTERNATE <br />DS-1 <br />PRE -FINISHED ALUMINUM DOWNSPOUT <br />MG-1 <br />METAL COPING - COLOR TO MATCH E-1 <br />AW-1 <br />PRE -FINISHED EXTRUDED ALUMINUM CANOPY <br />SF-1 <br />ALUMINUM STOREFRONT - KAWNEER 451 OR EQUAL 1" INSULATED LOW-E CLEAR GLASS <br />L-1 <br />DECORATIVE LIGHT FIXTURE A - SEE ELECTRICAL DRAWINGS <br />L-2 <br />DECORATIVE LIGHT FIXTURE B - SEE ELECTRICAL DRAWINGS <br />L-3 <br />DECORATIVE LIGHT FIXTURE C - SEE ELECTRICAL DRAWINGS <br />L-4 <br />WALL PACK LIGHT FIXTURE - SEE ELECTRICAL DRAWINGS <br />HM-1 <br />HOLLOW METAL DOOR. PAINT TO MATCH E-1 <br />HM-1 <br />STANDING SEAM METAL <br />HM-1 <br />METAL PANELJNG <br />HM-1 <br />METAL PANELJNG <br />HM-1 <br />METAL PANELJNG <br />TS-X <br />JUNCTION BOX & PULL STRING ONLY. <br />EXTERIOR FINISH SCHEDULE NOTES <br />1. H.M. DOORS AND FRAMES SHALL BE SHOP GALVANIZED AND FIELD PAINTED. <br />2. EDGE OF ROOF FLASHING AND FASCIAS AT EIFS CORNICES SHALL BE PREFINISHED AND <br />SHOP FABRICATED. <br />3. FLASHING, TRIMS, AND COLUMN COVERS AT ALUMINUM STOREFRONT SHALL MATCH <br />ALUMINUM STOREFRONT FINISH. <br />4. MASONRY GROUT COLOR IS NOT CALLED OUT ON THE ELEVATIONS. INFORMATION IS <br />NOTED IN THE EXTERIOR FINISH SCHEDULE. PROVIDE AS NOTED IN THE SCHEDULE. <br />5. SEE REFLECTED CEILING AND REFLECTED CANOPY PLANS FOR CEILING FINISH TAGS. <br />z <br />a5 <br />W <br />a <br />z <br />Of <br />.w D <br />v , <br />4 <br />VN <br />aJ N <br />4- <br />U) <br />V <br />0 <br />s.. W <br />Q <br />L^_` <br />W N <br />N <br />Q) <br />O� <br />L <br />.� <br />U <br />W <br />V 2 <br />N <br />N <br />O <br />N <br />O <br />CD <br />C? <br />H <br />W <br />D_ <br />O <br />u.. <br />W <br />U) <br />U) <br />"d <br />T <br />CnN <br />Lrl `9 <br />a O N <br />d <br />C: <br />g <br />U <br />00 <br />O v <br />" W z' <br />LL <br />N i <br />E �� i-- <br />°;v <br />v� <br />a <br />Q <br />z <br />N < <br />N <br />c <br />m <br />�" <br />�o v <br />0 0 <br />w <br />N <br />t6 <br />6 <br />z <br />Sheet Name: <br />ELEVATIONS <br />Proj #: <br />Issue Date: <br />210316 <br />09/01 /2022 <br />Sheet No.: <br />A-401 <br />Drawn By: <br />Checked By: <br />DL <br />DS <br />IRrd ..,I il,.l .M IN ti 11 I. 1 T--f ii I I I I n 1 T _F I I <br />ISSUED FOR CONSTRUCTION <br />
The URL can be used to link to this page
Your browser does not support the video tag.