Laserfiche WebLink
S <br />List Of Abbreviations <br />A A/C AIR CONDITION E EL ELEVATION L LAV LAVATORY S SC SOLID CORE <br />AB ANCHOR BOLT ELEC ELECTRICAL LBL LABEL SCHED SCHEDULE <br />ACT ACOUSTICAL CEILING TILE ELEV ELEVATOR LBS POUNDS SCP SCUPPER <br />AD ADJUSTABLE, ADJACENT EMER EMERGENCY LF LINEAR FEET SD SOAP DISPENSER <br />AFF ABOVE REF FINISHED EQ EQUAL LT WT LIGHT WEIGHT SEAL SEALANT <br />FLOOR (SLAB) EQUIP EQUIPMENT SECT SECTION <br />AHU AIR HANDLER UNIT ESC ESCALATOR M MAS MASONRY SF SQUARE FEET <br />ALT ALTERNATE EWC ELECTRIC MAX MAXIMUM SHT SHEET <br />ALUM ALUMINUM WATER COOLER MECH MECHANICAL SIM SIMILAR <br />ANOD ANODIZED EXIST EXISTING MFR MANUFACTURER SPEC SPECIFICATION <br />APPROX APPROXIMATE EXP EXPANSION MH MANHOLE SS STAINLESS STEEL, <br />ARCH ARCHITECT EXT EXTERIOR MIN MINIMUM SERVICE SINK <br />AUTO AUTOMATIC MIN MINIMUM, MINUTE STD STANDARD <br />F FACP FIRE ALARM MISC MISCELLANEOUS STL STEEL <br />B B 0 BOTTOM OF CONTROL PANEL MLDG MOLDING STOR STORAGE <br />BD BOARD FD FLOOR DRAIN MO MASONRY OPENING STRUC STRUCTURAL <br />BLDG BUILDING FDN FOUNDATION MR MOISTURE RESISTANT SUSP SUSPENDED <br />BM BEAM FIN FINISHED MTD MOUNTED SY SQUARE YARD <br />BRIG BEARING FLR FLOOR MTL METAL <br />BTM BOTTOM FIR FIRE RESISTANT MUL MULLION T T TREAD <br />BUR BUILT UP ROOF FR-S FIRE -RETARDANT T&G TONGUE & GROOVE <br />WOOD TREATMENT N NIC NOT IN CONTRACT TBL TABLE <br />C CB CATCH BASIN FT FEET, FOOT NOM NOMINAL TELE TELEPHONE <br />CG CORNER GUARD FTG FOOTING NTS NOT TO SCALE TEMP TEMPERED <br />CI CAST IRON FURR FURRING THK THICK <br />CJ CONTROL JOINT FLIT FUTURE 0 OC ON CENTER TLT TOILET <br />CL CENTER LINE OD OUTSIDE DIAMETER TO TOP OF <br />CLG CEILING G GA GAUGE OPP OPPOSITE TPD TOILET PAPER <br />CLO CLOSET GAL GALLON OVFL OVERFLOW DISPENSER <br />CLR CLEAR GALV GALVANIZED TS TUBE STEEL <br />CMU CONCRETE GB GRAB BAR P PL PLATE TV TELEVISION <br />MASONRY UNIT GC GENERAL CONTRACTOR PLAM PLASTIC LAMINATE TYP TYPICAL <br />CO CLEAN OUT GYP GYPSUM PLAS PLASTER <br />COL COLUMN PLBG PLUMBING U UON UNLESS OTHER - <br />CONIC CONCRETE H HB HOSE BIBB PLWD PLYWOOD WISE NOTED <br />CONST CONSTRUCTION HC HOLLOW CORE PNL PANEL UTIL UTILITY <br />CONT CONTINUOUS HDW HARDWARE PR PAIR <br />CONTR CONTRACTOR HM HOLLOW METAL PREFAB PREFABRICATED V VB VINYL BASE <br />CORR CORRIDOR HORIZ HORIZONTAL PT POINT VCT VINYL COMPOSITE TILE <br />CT CERAMIC TILE HR HOUR PT PRESSURE TREATED VERT VERTICAL <br />CTR CENTER HT HEIGHT PTD PAPER TOWEL DISPENSER VEST VESTIBULE <br />CU CONDENSING UNIT HTG HEATING PVC POLY VINYL CLORIDE VIF VERIFY IN FIELD <br />CW COLD WATER HVAC HEATING, VENTILATING VTR VENT THRU ROOF <br />& AIR CONDITIONING Q QT QUARRY TILE VWC VINYL WALL COVERING <br />D DBL DOUBLE HW HOT WATER <br />DEPT DEPARTMENT R R RADIUS, RISER, W W WIDTH <br />DET DETAIL I ID INSIDE DIAMETER THERMAL RESISTANCE W/ WITH <br />DF DRINKING FOUNTAIN IN INCH RD ROOF DRAIN W/O WITHOUT <br />DIA DIAMETER INCL INCLUDING RECP RECEPTACLE WC WATER CLOSET <br />DIM DIMENSION INSUL INSULATION REF REFERENCE WD WOOD <br />DISP DISPENSER INT INTERIOR REFR REFRIGERATOR WH WATER HEATER <br />DN DOWN INV INVERT REG REGLET WP WATERPROOF <br />DS DOWNSPOUT REINF REINFORCEMENT WT WEIGHT <br />DWG DRAWING J JAN JANITOR REQ REQUIRED WWF WELDED WIRE FABRIC <br />JB JUNCTION BOX REV REVISION WWM WELDED WIRE METAL <br />E EACH JT JOINT RM ROOM <br />EB EXPANSION BOLT RND ROUND Y YD YARD <br />EIFS EXTERIOR INSULATING L L LENGTH RO ROUGH OPENING <br />FINISH SYSTEM LAM LAMINATE RTU ROOF TOP UNIT <br />EJ EXPANSION JOINT <br />Legend <br />X -- GRID DESIGNATION Z� BUILDING SECTION <br />A301-2 A301-2 <br />102 ROOM NUMBER SHEET NUMBER SECTION NUMBER <br />102A DOOR NUMBER WALL SECTION <br />A30�2� <br />G) WINDOW TYPE SHEET NUMBER SECTION NUMBER <br />2O STOREFRONT TYPE A501-6 SECTION DETAIL <br />WALL TYPE SHEET NUMBER DETAIL NUMBER <br />O5 KEY NOTE A888-88 DETAIL REFERENCE <br />© REVISION NUMBER SHEET NUMBER DETAIL NUMBER <br />TO SOMETHING ELEVATIONS TAGS EXTERIOR ELEVATION <br />A201-2 MARKERS <br />SHEET NUMBER ELEVATION NUMBER <br />SPOT ELEVATION TAG <br />• 1 <br />4 A401 2 INTERIOR ELEVATION <br />NNORTH ARROW MARKERS <br />E'71) <br />SHEET NUMBER 3 ELEVATION NUMBER <br />BRICK ° . CONCRETE PLYWOOD <br />e• e ' <br />MASONRY ��/���/� COMPACTED STEEL <br />EARTH <br />General Notes <br />1. ALL WORK WILL COMPLY WITH LOCAL, STATE, AND NATIONAL CODES <br />RELATED TO THIS PROJECT. <br />2. THE WRITTEN DIMENSIONS PREVAIL ON THE CONSTRUCTION DOCUMENTS, <br />DO NOT SCALE THESE DRAWINGS. CONTRACTOR TO FIELD VERIFY ALL <br />DIMENSIONS AND CONDITIONS. IF ANY DISCREPANCY OCCURS, THE <br />CONTRACTOR SHALL NOTIFY THE ARCHITECT IN WRITING BEFORE <br />PROCEEDING WITH ANY WORK AFFECTED BY THE DISCREPANCY. <br />3. CONTRACTORS TO SECURE ALL PERMITS AND REQUIRED INSPECTIONS <br />NECESSARY TO OBTAIN A CERIFICATE OF OCCUPANCY. <br />4. CONTRACTORS ARE TO PROVIDE ALL TEMPORARY UTILITIES AND <br />INFRASTRUCTURE REQUIRED TO PERFORM THE WORK, INCLUDING <br />FIRE PROTECTION AS REQUIRED DURING CONSTRUCTION. <br />5. EACH CONTRACTOR AND SUBCONTRACTOR IS EXPECTED TO REVIEW ALL <br />CONTRACT DOCUMENTS AND SITE CONDITIONS PRIOR TO ISSUED BID. <br />CHANGE ORDERS WILL NOT BE APPROVED FOR FAILURE TO DO 80. <br />6. PRODUCTS SPECIFIED OR OTHERWISE INDICATED IN THE CONTRACT <br />DOCUMENTS SHALL NOT BE SUBSTITUED WITHOUT PRIOR WRITTEN <br />APPROVAL FROM THE ARCHITECT AND OWNER. <br />7. THE CONTRACTOR SHALL HAVE INSTALLATION INSTRUGTIONS FOR <br />ALL EQUIPMENT AND APPLIANCES ON SITE AT TIME OF INSPECTION. <br />. ' <br />GYPSUM <br />DRAINAGE <br />BOARD <br />ADopt <br />FILL <br />RIGID <br />:::::::::: <br />MR <br />INSULATION <br />BOARD <br />8. THIS CONTRACTOR SHALL COORDINATE ALL TRADES REQUIRED TO <br />COMPLETE THIS PROJECT AS REQUIRED TO ACTIVATE THE USE OF <br />THE FACILITY AS PLANNED. <br />9. THE EXISTING SHELL BUILDING IS FULLY SPRINKLERED AND HAS A <br />FULL FIRE ALARM SYSTEM. THESE SYSTEMS SHALL BE MODIFIED <br />AS NEEDED TO PROVIDE FIRE PROTECTION FOR THE SPECIFIED <br />TENANT SPACES, THE CONTRACTOR SHALL SUBMIT SIGNED AND <br />SEALED SHOP DRAWINGS AND HYDRAULIC CALCULATIONS TO THE <br />LOCAL JURISDICTION FOR PERMITTING. NO WORK ON THE FIRE <br />PROTECTION SYSTEMS SHALL TAKE PLACE UNTIL THE REQUIRED <br />PERMITS ARE OBTAINED BY THE FIRE PROTECTION SUB <br />CONTRACTOR. <br />10. ALL BUILDING MATERIALS SHALL COMPLY WITH THE REQUIRMENTS <br />OF TYPE II-B CONSTRUCTION. ALL PLYWOOD SHEATHING AND <br />WOOD BLOCKING SHALL BE FIRE RETARDANT TREATED (FRT) <br />11. SEE ENERGY CALCULATION ATTACHED TO THIS SUBMISSION <br />12. ALL WORK ON THE EXISTING BUILDING SHALL BE PERFORMED IN <br />ACCORDANCE WITH ALL EXISTING WARRANTIES. THE <br />CONTRACTOR SHALL CONTACT THE OWNER DIRECTLY TO OBTAIN <br />ALL EXISTING WARRANTY INFORMATION. THE CONTRACTOR SHALL <br />PROVIDE THE OWNER WITH DOCUMENTATION VERIFYING THAT ALL <br />EXISTING WARRANTIES HAVE BEEN MAINTAINED. <br />Legal Description <br />A TRACT OF LAND LYING IN THE NORTHEAST 1/4 OF SECTION 34 AND IN THE NORTHWEST 1/4 OF SECTION 35, TOWNSHIP 25 <br />SOUTH, RANGE 21 EAST, PASCO COUNTY, FLORIDA. THE SAME BEING A PORTION OF THE ZEPHYRHILLS COLONY COMPANT <br />LANDS SUBDIVISION OF SAID SECTION 34 AND 35 AS SHOWN ON THE PLAT OR MAP THEREOF RECORDED IN PLAT BOOK 1, PAGE <br />55 OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. <br />LESS AND EXCEPT THAT PORTION OF SAID TRACTS 58 AND 59 CONVEYED IN OFFICIAL RECORDS BOOK 1902, PAGE 690, PUBLIC <br />RECORDS OF PASCO COUNTY, FLORIDA. <br />SAID LAND CONTAINING 60.76 ACRES MORE OR LESS. <br />Vicinity MapNTS <br />7950 GALL BLVD, ZEPHYRHILLS, FLORIDA <br />Code Information <br />JURISDICTION AUTHORITY <br />CITY OF ZEPHYRHILLS <br />5335 8TH STREET <br />ZEPHYRHILLS, FL 33542 <br />Tenant Buildout for Space D5D6 <br />Building D at Zephyr Commons <br />7850 Gall Blvd, Zeiphyrhills, FL <br />Scope of Work <br />1. THE SCOPE IS LIMITED TO TENANT SPACE D5D6 IN BLDG D. <br />2. THE SCOPE DOES NOT INCLUDE ANY WORK RELATED TO THE PARKING LOT, LANDSCAPING, SITE UTILITIES, <br />SITE DRAINAGE, SITE LIGHTING, OR ANY OTHER SITE FEATURES.. <br />3. THE SCOPE DOES NOT INCLUDE ANY WORK ON ANY OF THE BUILDINGS IN THE SHOPPING CENTER OTHER <br />THAN BLDG D. <br />4. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE SIDEWALKS, HARDSCAPE AREAS, OR LANDSCAPE AEAS <br />IMMEDIATELY ADJACENT TO ANY OF THE BUILDINGS. <br />5. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE FINISHES, AWNINGS, STONE WORK, OR DECORATIVE <br />TRIM ON THE EXTERIOR ELEVATIONS OF ANY OF THE BUILDINGS. <br />6. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE STOREFRONT SYSTEMS, DECORATIVE WINDOWS, <br />FRONT STOREFRONT DOORS, OR REAR HOLLOW METAL DOORS ON ANY OF THE BUILDINGS. <br />7. THE SCOPE DOES NOT INCLUDE ANY WORK ON THE EXISTING ROOF SYSTEM OTHER THAN WHAT IS <br />REQUIRED TO ADD AN EXHAUST FAN AND A VENT FOR THE NEW RESTROOM. THE SCOPE DOES NOT <br />INCLUDE ANY WORK ON THE SHINGLE ROOFS OR ON THE ROOF DRAINAGE SYSTEMS. <br />8. THE SCOPE ON THE FRONT FRAMED WALL SHALL BE LIMITED TO WHAT IS NEEDED TO CONSTRUCT THE <br />NEW INTERIOR WALLS. THE EXISTING 1 HOUR FIRE RATING SHALL BE MAINTAINED. <br />9. THE SCOPE DOES NOT INCLUDE ANY NEW TENANT DEMISING WALLS. <br />0S <br />10. THE SCOPE INCLUDES ADDING SHEATHING OVER METAL FURRING & RIGID INSULATION ON THE INSIDE OF <br />_ - - THE ENTIRE SIDE CMU WALL & ON THE INSIDE OF THE REAR CMU WALL INSIDE THE RESTROOM ONLY. <br />11. THE SCOPE INCLUDES INSTALLING A NEW RESTROOM PER ADA REQUIRMENTS. <br />12. THE SCOPE INCLUDES INSTALLING NEW 2' x 4' ACT CEILINGS IN THE RESTROOM AND THE MAIN ROOM OF <br />THE TENANT SPACE. <br />3 SIGNED & SEALED SETS FOR PERMIT <br />(813) 780-0020 - PHONE 13. THE SCOPE DOES NOT INCLUDE ANY WORK ON THE FOUNDATIONS, COLUMNS, BEAMS, JOISTS, ROOF <br />(813) 780-0021 - FAX DECK, OR TRUSSES. THE SCOPE DOES NOT INCLUDE ANY WORK ON THE STRUCTURAL COMPONENTS OF <br />THE MASONRY WALL. THE SCOPE DOES NOT INCLUDE ANY STRUCTURAL WORK TO THE EXISTING LIGHT <br />GAUGE FRAMING. <br />ADOPTED CODES: <br />14. THE SCOPE INCLUDES SAW -CUTTING THE EXISTING FLOOR SLAB AS NEEDED TO PROVIDE THE NEW <br />BUILDING: <br />FLORIDA BUILDING CODE, BUILDING - 2007 (W/ 2009 AMENDMENTS) <br />RESTROOM. <br />FIRE: <br />FLORIDA FIRE PREVENTION CODE - 2007 (W/ 2009 AMENDMENTS) <br />(CHAPTER 36 - NFPA 1 & NFPA 101 W/ STATE FIRE MARSHAL AMENDMENTS) <br />15. THE SCOPE INCLUDES RE -POURING ANY PORTION OF THE EXISTING SLAB THAT IS SAW -CUT. IT ALSO <br />PLUMBING: <br />FLORIDA BUILDING CODE, PLUMBING - 2007 (W/ 2009 AMENDMENTS) <br />INCLUDES POURING A NEW SLAB IN THE AREA OF THE EXISTING SLAB LEAVEOUT AT THE REAR OF TENANT <br />MECHANICAL: <br />FLORIDA BUILDING CODE, MECHANICAL - 2007 (W/ 2009 AMENDMENTS) <br />SPACE D5D6. <br />ELECTRICAL: <br />FLORIDA BUILDING CODE, BUILDING - 2007 (W/ 2009 AMENDMENTS) <br />(CHAPTER 27 - NFPA 70, NATIONAL ELECTRIC CODE) <br />16. THE EXISTING BUILDING HAS A FIRE SPRINKLER SYSTEM WITH THE HEADS TURNED UP. THE SCOPE <br />FUEL/GAS: <br />FLORIDA BUILDING CODE, FUEUGAS - 2007 (W/ 2009 AMENDMENTS) <br />INCLUDES TURNING DOWN THE SPRINKLER HEADS AND MOVING THEM AS NEEDED TO FIT THE CEILING <br />ACCESSIBILITY: <br />FLORIDA BUILDING CODE, BUILDING - 2007 (W/ 2009 AMENDMENTS) <br />LAYOUT. THE SCOPE INCLUDES DESIGN AND PERMITTING BY THE FIRE SPRINKLER SUBCONTRACTOR'S <br />(CHAPTER 11 - FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION). <br />SPECIALTY ENGINEER THROUGH HIS SHOP DRAWINGS. <br />ENERGY: <br />FLORIDA BUILDING CODE, BUILDING - 2007 (W/ 2009 AMENDMENTS) <br />(CHAPTER 13 - FLORIDA ENERGY EFFICIENCY FOR BUILDING CONSTRUCTION). <br />17. THE SCOPE INCLUDES PROVIDING NEW SANITARY SERVICE, NEW VENT SYSTEM, AND NEW POTABLE <br />BUILDING AND CONSTRUCTION DATA <br />OCCUPANCY CLASSIFICATION (FBC 309) <br />CONSTRUCTION TYPE (FBC TABLE 601) <br />MAXIMUM HEIGHT AND AREA (FBC TABLE 503) <br />MAXIMUM HEIGHT <br />ACTUAL HEIGHT <br />MAXIMUM AREA <br />ACTUAL AREAS <br />WATER SERVICE FOR THE RESTROOM. <br />18. THE SCOPE DOES NOT INCLUDE ANY WORK TO ANY UNDERGROUND SANITARY LINES OTHER THAN WHAT <br />IS REQUIRED FOR CONNECTION OF THE NEW SANITARY LINES. THE SCOPE DOES NOT INCLUDE ANY <br />WORK TO ANY OF THE EXISTING CLEAN OUTS <br />GROUP M - MERCANTILE. <br />TYPE II-B, FULLY SPRINKLERED <br />55'-0" - FOUR STORIES <br />35'-0" - ONE STORY <br />12,500 SF <br />8,600 SF <br />NOTE: <br />WIND ZONE =110 MPH. IMPORTANCE FACTOR =1.00 <br />BLDG CATEGORY = II, ENCLOSED. WIND EXPOSURE = B <br />THE SCOPE OF WORK FOR THIS INTERIOR BUILD OUT DOES NOT INCLUDE ANY <br />MODIFICATIONS TO ANY EXTERIOR DOORS OR WINDOWS. ALL MODIFICATIONS <br />TO THE EXISTING ROOF SYSTEM SHALL BE PERFORMED IN ACCORDANCE WITH <br />THE MIAMI DADE NOTICE OF ACCEPTANCE (NOA). <br />Contact Information <br />CLIENT: PRIMERICA GROUP ONE, INC. <br />3629 MADACA LANE <br />TAMPA, FL. 33618 <br />(813) 933-0629 PHONE <br />(813) 935-3420 FAX <br />CONTACT: ADAM ROBINSON <br />ARCHITECT: CUHACI & PETERSON, ARCHITECTS, LLC <br />1925 PROSPECT AVE <br />ORLANDO, FL 32814 <br />(407) 661-9100 PHONE <br />(407) 661-9101 FAX <br />CONTACT: GABRIEL ROBERTSON <br />CIVIL AVID GROUP <br />ENGINEER: 8659 BAYPINE ROAD, STE 304 <br />JACKSONVILLE, FLORIDA 32256 <br />(904) 737-4001 PHONE <br />(904) 252-7030 FAX <br />CONTACT: BOB PIERRO <br />grebe edr�ed � , �� �d ie • <br />NftW b a the ogntrft in woe vA <br />8 Codes. This M*w is riot kbrided <br />=sole Of the � Pis. tt I, the <br />���� b sure that the plans are in <br />e NFPA codes and <br />kcd aramy"L In tfie $+r+�tt fixther examination or <br />M e* of non-compliance, it shall be <br />the ot's . at their sole expense to <br />WN t10eeWU in °awe The City Mumes no <br />ft� s retobeincom <br />WIM = WPMM NFPA Codes and loci wftmw, <br />SHEET NO. <br />ARCHITECTURAL <br />SUBMITTED PLAN S) HAVE BEEN REVIEWED <br />$Y ZEPHYRHIL F E MARSHAL'S OFFICE <br />Date: ".. , 4 f i <br />koviewer: <br />STRUCTURAL CUHACI & PETERSON, ARCHITECTS, LLC <br />ENGINEER: 1925 PROSPECT AVE <br />ORLANDO, FL 32814 <br />(407) 661-9100 PHONE <br />(407) 661-9101 FAX <br />CONTACT: BRETT RYLANDS <br />MECHANICAL <br />CUHACI & PETERSON, ARCHITECTS, LLC <br />ENGINEER: <br />1925 PROSPECT AVE <br />ORLANDO, FL 32814 <br />(407) 661-9100 PHONE <br />(407) 661-9101 FAX <br />CONTACT: JOE KEENE <br />ELECTRICAL <br />CUHACI & PETERSON, ARCHITECTS, LLC <br />ENGINEER: <br />1925 PROSPECT AVE <br />ORLANDO, FL 32814 <br />(407) 661-9100 PHONE <br />(407) 661-9101 FAX <br />CONTACT: TIM NASH <br />Al <br />40'-0" (LEASABLE WIDTH) <br />AREA OF INTERIOR WORK FOR D5D6 <br />44 <br />N <br />o <br />0 <br />U <br />� <br />19. THE SCOPE INCLUDES REMOVAL OF ANY UNUSED PORTION OF THE EXISTING ABOVE GROUND STUBS IN <br />FOR SPACE D5D6. <br />20. THE SCOPE DOES NOT INCLUDE ANY FLOOR DRAINS OR ANY STUB OUTS FOR FUTURE CONNECTION TO <br />THE SANITARY OR VENT SYSTEMS. <br />21. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE WATER METER, THE COLD WATER MAIN, OR ANY OF <br />THE VALVES. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE COLD WATER BRANCH LINE OTHER <br />THAN WHAT IS REQUIRED FOR CONNECTION OF THE NEW COLD WATER PIPING. <br />22. THE SCOPE DOES NOT INCLUDE ANY PROVISIONS FOR HOT WATER OR ANY STUB OUTS OR VALVES FOR <br />FUTURE CONNECTION TO THE COLD WATER SYSTEM. <br />23. THE SCOPE DOES NOT INCLUDE ANY WORK RELATED TO GAS OR GREASE. <br />24. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE EXISTING RTU'S ABOVE SPACE D5D6 OTHER THAN <br />WHAT IS REQUIRED TO CONNECT NEW HVAC DUCTING. THE SCOPE DOES NOT INCLUDE ANY WORK FOR <br />ANY OTHER RTU'S OR ANY OF THE EXISTING CONDENSATE LINES. <br />25. THE SCOPE INCLUDES PROVIDING A FULL HVAC SYSTEM. <br />26, THE SCOPE DOES NOT INCLUDE ANY WORK TO THE BUILDING TRANSFORMER, SECONDARY CONDUIT, <br />SECONDARY WIRE, MAIN DISCONNECT, WIREWAY, TENANT METER OR TENANT DISCONNECT. <br />27. THE SCOPE INCLUDES PROVIDING A NEW 200 AMP TENANT PANEL CONNECTED TO THE EXISTING <br />DISCONNECT VIA NEW WIRE PULLED THROUGH THE EXISTING EMPTY CONDUIT. <br />28. THE SCOPE INCLUDES PROVIDING NEW POWER RECEPTACLES WIRED TO THE TENANT PANEL. <br />29. THE SCOPE DOES NOT INCLUDE ANY CHANGES TO THE EXISTING SIGN JUNCTION BOXES ON THE FRONT <br />` > o <br />OF THE BUILDING OTHER THAN WIRING THEM TO THE TENANT PANEL. <br />m <br />rn <br />30. THE SCOPE INCLUDES WIRING THE EXISTING RTU'S AND ALL OTHER COMPONENTS OF THE HVAC SYSTEM <br />` Z <br />TO THE TENANT PANEL. <br />w U_ <br />31. THE SCOPE DOES NOT INCLUDE ANY CHANGES TO THE SCONCE FIXTURES ON THE FRONT OF THE <br />"' <br />BUILDING, THE UNDER CANOPY LIGHTING, OR THEIR WIRING. <br />32. THE SCOPE DOES NOT INCLUDE ANY CHANGES TO THE EXISTING WALL MOUNTED LIGHT FIXTURE ON THE <br />REAR OF THE BUILDING OTHER THAN WIRING IT TO THE TENANT PANEL VIA A LIGHT SWITCH. <br />33. THE SCOPE INCLUDES PROVIDING NEW EXIT AND EMERGENCY LIGHTS. THESE LIGHTS SHALL BE WIRED <br />TO THE NEW TENANT PANEL. <br />34. THE SCOPE INCLUDES PROVIDING NEW 2' x 4' FLUORESCENT LIGHT FIXTURES WIRED TO THE TENANT <br />PANEL. <br />35. THE SCOPE DOES NOT INCLUDE ANY CHANGES TO THE EXISTING TELEPHONE SYSTEM. <br />36. THE EXISTING BUILDING HAS A FIRE ALARM SYSTEM. THE SCOPE INCLUDES MODIFYING THE SYSTEM AS <br />NEEDED FOR THE TENANT BUILD OUT. THE SCOPE INCLUDES DESIGN AND PERMITTING OF THE FIRE <br />ALARM SYSTEM BY THE CONTRACTOR THROUGH SHOP DRAWINGS. <br />D11-ilk 10,U)IL1�'v,� <br />4yjLj1 r Co„._ <br />r <br />C� <br />T �tiVLLL Li.' 4�� 1 ! <br />_ �d�`` 7 <br />Drawing Index <br />TITLE ON SHEETI 11 PERMIT SET <br />2010_04-26 <br />REVIEW DATE y(i <br />CITY OF ZEPHYRHILL <br />PLANS EXAMINER C5 <br />COVER SHEET <br />X <br />PROJECT SITE PLAN <br />X <br />SPACE D5D6 PLANS <br />X <br />SPACE D5D6 DETAILS <br />X <br />D5D6 SPECIFICATIONS <br />X <br />D5D6 SPECIFICATIONS <br />X <br />D5D6 SPECIFICATIONS <br />X <br />D5D6 SPECIFICATIONS <br />X <br />FIRE PROTECTION <br />FIRE PROTECTION NOTE - THE EXISTING SHELL BUILDING IS FULLY SPRINKLERED. THE SPRINKLER SYSTEM SHALL BE MODIFIED AS NEEDED FOR THE BUILD OUT. ALL MODIFICATIONS TO THE SPRINKLER SYSTEM SHALL <br />BE DESIGNED BY THE CONTRACTOR. THE CONTRACTOR SHALL SUBMIT SIGNED AND SEALED SHOP DRAWINGS AND HYDRAULIC CALCULATIONS TO THE LOCAL JURISDICTION FOR PERMITTING. <br />PLUMBING <br />P101 PLUMBING GENERAL INFORMATION FLOOR PLAN & RISERS X <br />MECHANICAL <br />M101 MECHANICAL GENERAL INFORMATION & FLOOR PLAN X <br />ELECTRICAL <br />E101 ELECTRICAL LEGEND SCHEDULES POWER & LIGHTING PLANS X <br />E501 ELECTRICAL SPECIFICATIONS X <br />FIRE ALARM NOTE - THE EXISTING SHELL BUILDING HAS A FULL FIRE ALARM SYSTEM. THE FIRE ALARM SYSTEM SHALL BE MODIFIED AS NEEDED FOR THE BUILD OUT. ALL MODIFICATIONS TO THE FIRE <br />ALARM SYSTEM SHALL BE DESIGNED BY THE CONTRACTOR. THE CONTRACTOR SHALL SUBMIT SIGNED AND SEALED SHOP DRAWINGS TO THE LOCAL JURISDICTION FOR PERMITTING. <br />t Al- ❑ i. ,l I IP. <br />