Laserfiche WebLink
I <br />4;I <br />11© <br />II© <br />Bldg A � o g <br />FUTURE BUILDING TO BE <br />DESIGNED, PERMITTED, <br />AND CONSTRUCTED AS <br />A SEPARATE SET <br />OF DRAWINGS <br />+ I <br />►� '* FIRE HYDRANT_ <br />I <br />RE: CIVIL PLANS <br />u <br />Bldg B <br />EXISTING BUILDING <br />TO REMAIN AS IS. <br />I <br />I I � <br />I <br />Parcel 1 <br />! THIS PARCEL TO BE <br />DESIGNED, PERMITTED, <br />AND CONSTRUCTED AS <br />A SEPARATE SET ,, <br />OF DRAWINGS $ <br />I' <br />II � `,• 1 1 <br />r <br />Bldg C <br />EXISTING BUILDING <br />TO REMAIN AS IS. <br />rim - n r Urcruv i <br />RE: CIVIL PLANS 1 <br />Bldg F <br />EXISTING BUILDING <br />TO REMAIN AS IS. <br />i <br />FIRE HYDRANT <br />RE: CIVIL PLANS <br />EXISTING BLDG D <br />FIRE RISER ROOM <br />39'-9" I <br />I APPROX. DIMENSION FROM <br />I INSIDE FACE OF EXISTING Bldg E <br />I CMU TO INSIDE FACE OF <br />Bldg D D51D6 I EXISTING DEMISING WALL EXISTING BUILDING <br />VERIFY IN FIELD TO REMAIN AS IS. <br />� I <br />IG - - REFER TO SHEET A101 FOR EXISTING <br />FIRE HYDRANT <br />RE: CIVIL PLANS <br />C= <br />IIIIII,;%' <br />� , `(_ .\\..- ;, F-� 1:, 1, ;,,1 TI , ;:.:•, �; '.r u- IIYI ,,FI E HYDRANT <br />RE: CIVIL PLANS <br />_ <br />44) <br />30 _ <br />�' `► `► FIRE HYDRANT <br />FIRE HYDRANT RE: CIVIL PLANS <br />�I I <br />RE: CIVIL PLANS O <br />I <br />I <br />:i <br />I, 30 ; ! Parcel 2 Parcel 3 °" °. Parcel 4 _ Parcel 5 <br />PARCEL BE I I I THIS PARCEL TO BE <br />THIS C 0 THIS PARCEL TO BE ° : ( THIS PARCEL TO BE DESIGNED, PERMITTED, <br />DESIGNED, PERMITTED, I DESIGNED, PERMITTED, DESIGNED, PERMITTED, AND CONSTRUCTED AS <br />AND CONSTRUCTED AS AND CONSTRUCTED AS <br />A SEPARATE SET AND CONSTRUCTED AS A SEPARATE SET Q <br />OF DRAWINGS A SEPARATE SET A SEPARATE SET <br />OF DRAWINGS ° OF DRAWINGS OF DRAWINGS <br />i � I <br />f i <br />I <br />I <br />I <br />I I �1N0 I <br />.I <br />_-- ....... <br />- - ,` <br />- <br />Overall Project Site Plan <br />N SCALE: 1" = 40'-0" <br />THIS SET OF DRAWINGS IS LIMITED TO TENANT D5D6 ONLY. REFER TO THE COVER SHEET FORA COMPLETE <br />DESCRIPTION OF THE SCOPE OF WORK COVERED IN THIS SET OF DRAWINGS. <br />BUIILDINGS B, C, E, & F ARE EXISTING AND ARE TO REMAIN AS IS. <br />ALL OTHER FUTURE BUILDINGS AND PARCELS SHALL BE DESIGNED, PERMITTED, AND CONSTRUCTED SEPARATELY. <br />FOR COMPLETE SITE WORK INFORMATION, REFER TO THE CIVIL DRAWINGS PREPARED BY AVID. <br />FOR COMPLETE LANDSCAPE AND IRRIGATION INFORMATION, REFER TO THE CIVIL DRAWINGS PREPARED BY AVID. <br />FOR COMPLETE SITE LIGHTING INFORMATION, REFER TO THE BUILDING D SHELL ELECTRICAL DRAWINGS. <br />Elevation & Grading Notes <br />1. ABBREVIATIONS: <br />TOS - TOP OF FLOOR SLAB INSIDE BUILDING <br />TOC - TOP OF CURB AT EDGE OF SIDEWALK <br />TOP - TOP OF PAVING <br />2. EXISTING TOS=113.00'. <br />3. ALL SIDEWALKS ARE EXISTING AND START 1l4" BELOW THE <br />TOS AT ALL DOORS. <br />4. ALL EXTERIOR DOORS ARE EXISTING AND HAVE EXISTING <br />THRESHOLDS THAT DO NOT EXCEED 1/2" IN HEIGHT. <br />5. ALL SIDEWALKS ARE EXISTING AND SLOPE AWAY FROM THE <br />BUILDING AT A RATE BETWEEN 1% MIN AND 2% MAX. <br />6. AT ALL FRONT SIDEWALKS, TOC IS 6" MAX ABOVE ADJACENT TOP. <br />7. AT ALL REAR SIDEWALKS, TOC IS FLUSH WITH ADJACENT TOP. <br />8. ALL HANDICAP RAMPS ARE EXISTING AND HAVE A SLOPE OF 1:14 <br />MAX. THE SURFACES OF ALL CURB RAMPS HAVE RAISED <br />DETECTABLE WARNING FINISHES. <br />9. THE BOTTOMS OF ALL HANDICAP RAMPS ARE FLUSH WITH <br />THE ADJACENT TOP <br />10. REFER TO CIVIL DRAWINGS FOR EXACT ELEVATIONS. <br />11. THE CONTRACTOR SHALL FIELD VERIFY ALL SIDEWALK AND <br />GRADING CONDITIONS PRIOR TO STARTING WORK. THE GC <br />SHALL NOTIFY THE ARCHITECT IMMEDIATELY IF ANY OF THE <br />EXISTING CONDITIONS DO NOT MEET ADA REQUIREMENTS. <br />Fire Marshal's Checklist <br />EGRESS TRAVEL AND EXITS <br />RE: LIFESAFETY PLAN & CODE INFO ON A101 <br />EXIT AND EMERGENCY LIGHTS <br />RE: LIFESAFETY PLAN ON A101 <br />A FIRE ALARM SYSTEM WILL BE DESIGNED AND PERMITTED BY <br />SMOKE DETECTORS <br />CONTRACTOR'S SHOP DRAWINGS. RE: CODE INFORMATION ON A101 <br />FIRE EXTINGUISHERS <br />RE: LIFESAFETY PLAN ON A101 FOR LOCATIONS <br />FIRE RATED WALLS <br />RE: LIFESAFETY PLAN ON A101 FOR LOCATIONS & UL DETAILS <br />ALL DOORS SHALL HAVE HARDWARE THAT COMPLIES WITH <br />PANIC HARDWARE <br />REQUIREMENTS FOR EGRESS AND ADA ACCESSIBILITY. <br />RE: LIFESAFETY PLAN ON A101 FOR DOOR LOCATIONS <br />DUCT DETECTORS SHALL BE PROVIDED AS REQUIRED BY SMACNA, NFPA, <br />DUCT DETECTORS <br />AS WELL AS ANY OTHER APPLICABLE CODE <br />RE: MECHANICAL DRAWINGS FOR HVAC INFORMATION <br />EMERGENCY GENERATOR <br />NONE REQUIRED. NONE PROVIDED. <br />RE: A101 FOR ROOF FINISH INFO & CODE INFORMATION <br />INTERIOR FINISHES <br />FOR FLAME SPREAD RATINGS <br />SITE PLAN SHOWING ADJACENT <br />RE: OVERALL PROJECT SITE PLAN ON A100. FOR COMPLETE SITE <br />ROADWAYS, BUILDINGS, AND <br />WORK AND UTILITY INFORMATION, RE: CIVIL DRAWINGS BY AVID. <br />FIRE HYDRANTS <br />FULL SYSTEM PROVIDED. TO BE DESIGNED AND PERMITTED BY <br />FIRE ALARM <br />CONTRACTOR'S SHOP DRAWINGS. RE: CODE INFORMATION ON A101 <br />FULL SYSTEM PROVIDED. TO BE DESIGNED AND PERMITTED BY <br />SPRINKLERS <br />CONTRACTOR'S SHOP DRAWINGS. RE: CODE INFORMATION ON Al01 <br />GAS USAGE <br />NONE REQUIRED. NONE PROVIDED. <br />I <br />o <br />�a <br />00 <br />00 <br />r <br />� <br />u <br />w <br />•� <br />o <br />>o <br />do <br />v <br />ao <br />4 <br />Cq <br />CN <br />3 <br />r� <br />u <br />U <br />C <br />N <br />C <br />O <br />CL <br />0 <br />C7 w <br />cuZV <br />V<m <br />cM <br />O LL <br />Q <br />ESQ <br />w <br />s` N CL <br />M I- <br />J <br />U <br />Cn <br />C <br />O <br />E <br />E <br />O <br />U <br />L <br />N <br />CIO <br />^ <br />�o <br />J <br />Q m <br />Q <br />U <br />Q5- <br />Cie)JU) <br />m J <br />LLJ <br />_� 2 <br />J <br />F- <br />moo= <br />Lu <br />o <br />I—CDN <br />Of <br />CL <br />40 <br />Z <br />� w <br />J � <br />¢Q <br />W J <br />i <br />w w <br />Lu <br />w <br />Cn <br />w <br />CL <br />co <br />N <br />W <br />CO1 <br />Q <br />ul <br />o <br />N <br />J <br />w <br />N <br />Q <br />� <br />c+a <br />o <br />0 <br />C)cD <br />W <br />ZLu <br />N <br />N <br />C7 <br />W <br />m <br />¢ <br />CL <br />0 <br />r <br />U <br />Al 00 <br />61TF�T.,,IIIh I! .k �IFalclaio�Ill�k.I,III..at�Vl r0,�� I'il� 4II� <br />