VC <br />V �Vvl <br />/B\ <br />SANITARY WASTE RISER DIAGRAM <br />NTS <br />UNZ <br />off <br />PICO <br />GENERAL NOTES: <br />1. CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING AND <br />CONSTRUCTION TO SURVEY EXISTING CONDITIONS. <br />2. CONTRACTOR SHALL INSTALL APPLIANCES PER <br />MANUFACTURER'S PLUMBING REQUIREMENTS. <br />3. CONTRACTOR SHALL COORDINATE THE SANITARY VENTING WITH <br />THE EXISTING VTR'S ((1) 3- & (1) 2-) PROVIDED IN THE SHELL <br />PACKAGE. IF THE EXISTING VTR'S ARE WITHIN 10'-0" OF THE <br />RTU OUTSIDE AIR INTAKES THE CONTRACTOR SHALL <br />COORDINATE NEW LOCATIONS. <br />KEY NOTES: <br />CONTRACTOR SHALL TIE NEW 3- SANITARY WASTE LINE INTO <br />NEAREST EXISTING SANITARY LINE OF ADEQUATE SIZE. <br />PROVIDE 3" VENT THRU ROOF. CONTRACTOR SHALL COORDINATE <br />EXACT LOCATION WITH ROOFTOP AIR HANDLING UNITS TO MAINTAIN A <br />MINIMUM OF 10'-0" CLEARANCE BETWEEN THE VENT AND THE <br />ROOFTOP UNIT'S OUTSIDE AIR INTAKE. <br />FIXTURES PIPE SIZE <br />FIXTURE <br />SAN SIZE <br />VENT SIZE <br />WATER CLOSET <br />3" <br />2 <br />LAV / SINK <br />3" <br />1-1/2- <br />ELECT WATER COOLER <br />3" <br />1-1/2- <br />FLOOR DRAIN <br />3" <br />2" <br />NOTE: <br />PLUMBING CONTRACTOR SHALL FIELD VERIFY, USING SUCH <br />METHODS AS A SEWER CAMERA, LOW FREQUENCY GPR (GROUND <br />PENETRATING RADAR) OR EM (ELECTROMAGNETIC) UTILITY <br />LOCATING METHODS DURING DEMOLITION PHASE OF PROJECT TO <br />DETERMINE THE EXACT CONDITION OF PIPE, LOCATION, SIZE, <br />INVERT AND DIREC11ON OF FLOW OF ALL EXISTING <br />SANITARY/GREASE WASTE LINES WITHIN SCOPE OF PROJECT. <br />DISCREPANCIES AND UNFORESEEN CONDITIONS ARE TO BE <br />BROUGHT TO THE ATTENTION OF THE OWNER, ARCHITECT AND <br />PROJECT ENGINEER PRIOR TO PROCEEDING WITH DEMOLITION IN <br />THE AREA OF CONCERN. <br />CAMPBELL + VAN DUSEN <br />ARCHITECTURE INTERIOR DESIGN <br />www.CVDstudio.com <br />CAMPBELL + VAN DUSEN Design Studio, LLC. <br />255 South Orange Avenue Suite # 1240 <br />Orlando, Florida 32801 <br />Phone: 407.930.6016 <br />FL. Lic. No. AA26003339 <br />ARCHITECT OF RECORD <br />FRANK W. CAMPBELL AIA <br />FL LIC NO. AROO 16053 <br />COPY OF THIS PLAN 15 NOT VALID UNLESS SIGNED, <br />SEALED AND DATED BY THE ARCHITECT OF RECORD <br />\px11II11j/// <br />\,qR JAp <br />0. <br />is CO <br />OP <br />A. <br />01?/DA <br />0- <br />Taylor J. Lewis, PE, <br />FL Reg. No. 90018 <br />COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, <br />SEALED AND DATED BY THE ENGINEER OF RECORD <br />I <br />Lj- <br />0 <br />r'-4 <br />ry <br />I <br />U <br />< <br />0 <br />L/) <br />L.Lj <br />L1J <br />> <br />I <br />co <br />I-- <br />F— <br />+ <br />Lr) <br />T <br />(-) <br />= <br />---0 <br />rl.*, <br />< <br />LU <br />LLJ <br />0 <br />-10 1- <br />L11 <br />�-o L0 <br />0!!� <br />< <br />3�: <br />or-0, <br />X <br />ru--4j <br />(1yo) <br />CONSTRUCTION DOCUMENTS <br />03.24.2023 <br />PRINCIPAL IN CHARGE <br />F. CAMPBELL <br />..................... ......... ........... .......... ........ <br />PROJECT MANAGER <br />M. TORRES <br />............... I ....................... ........... ........ <br />ADVENT HEALTH <br />WELL 65+ <br />ZEPHYRHILLS <br />22-0328-01 <br />MEP CONSULTING <br />SANITARY WASTE <br />ENGINEERS <br />SINCE 1977 <br />RISER DIAGRAM <br />FL REG NO. 3089 <br />2016 ALDEN RD. <br />ORLANDO, FL <br />32803 <br />(407) 246-1688 <br />WWW.PEIRACOM <br />P3* I <br />PEI PROXCT <br />22121 <br />