SANITARY WASTE RENOVATION PLAN <br />P2. 1) 1/411 = 1 1-011 <br />/—OA <br />- - —OD <br />OE <br />OF <br />GENERAL NOTES: <br />1. CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING AND <br />CONSTRUCTION TO SURVEY EXISTING CONDITIONS. <br />2. CONTRACTOR SHALL INSTALL APPLIANCES PER <br />MANUFACTURER'S PLUMBING REQUIREMENTS. <br />KEY NOTES: <br />(D CONTRACTOR SHALL TiE NEW 3' SANITARY WASTE LINE INTO <br />//B\ NEAREST EXISTING SANITARY LINE OF ADEQUATE SIZE. <br />CONTRACTOR SHALL COORDINATE CENTERING THE WALL CLEANOUT IN <br />THE SPACE WERE THE ROLL —OUT CABINETRY RESIDES. REFER TO <br />ARCHITECTURAL PLANS FOR CABINETRY DETAILS. <br />EXISTING STORM DRAIN AND OVERFLOW PIPING. CONTRACTOR SHAH <br />COORDINATE ALL DISCIPLINES. <br />FIXTURES PIPE SIZE <br />FIXTURE <br />SAN SIZE <br />VENT SIZE <br />WATER CLOSET <br />3" <br />2" <br />LAV / SINK <br />3* <br />1-1/2" <br />WATER COOLER <br />3' <br />1-1/2- <br />-ELECT <br />FLOOR DRAIN <br />3m <br />2" <br />NOTE: <br />PLUMBING CONTRACTOR SHALL FIELD VERIFY, USING SUCH <br />METHODS AS A SEWER CAMERA, LOW FREQUENCY GPR (GROUND <br />PENETRATING RADAR) OR EM (ELECTROMAGNETIC) UTILITY <br />LOCATING METHODS DURING DEMOLITION PHASE OF PROJECT TO <br />DETERMINE THE EXACT CONDITION OF PIPE, LOCATION, SIZE, <br />INVERT AND DIRECTION OF FLOW OF ALL EXISTING <br />SANITARY/GREASE WASTE LINES WITHIN SCOPE OF PROJECT. <br />DISCREPANCIES AND UNFORESEEN CONDITIONS ARE TO BE <br />BROUGHT TO THE ATTEN11ON OF THE OWNER, ARCHITECT AND <br />PROJECT ENGINEER PRIOR TO PROCEEDING WITH DEMOLITION IN <br />THE AREA OF CONCERN. <br />www.CVDstudio.com <br />CAMPBELL + VAN DUSEN Design Studio, LLC, <br />255 South Orange Avenue Suite # 1240 <br />Orlando, Florida 32801 <br />Phone: 407.930.6016 <br />FL. Lic. No. AA26003339 <br />ARCHITECT OF RECORD <br />FRANK W. CAMPBELL AIA <br />FL LIC NO. AR001 6053 <br />COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, <br />SEALED AND DATED BY THE ARCHITECT OF RECORD <br />\0\1111 I////// <br />NN \pkmSS4 <br />& . ............. <br />cews <br />\kp <br />S-T P'-f E OF <br />.......... ............ . <br />N <br />Ili; SfONA\� <br />Taylor J. Lewis, PE, <br />FL Reg. No. 90018 <br />COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, <br />SEALED AND DATED BY THE ENGINEER OF RECORD <br />I <br />Lj_ <br />ry <br />0 <br />LU <br />r,v <br />F— <br />P-4 <br />U <br />I <br />< <br />(/) <br />U_j <br />L.LJ <br />> <br />_j <br />F— <br />F— <br />+ <br />Lr-) <br />U-17 <br />__1.0 <br />r1o" <br />LU <br />LL] <br />0 <br />>'IT <br />C) <br />Lu <br />'0 L(.) <br />0!:� <br />< <br />3: <br />or-2 <br />0- <br />rL�L_l <br />(1y"') <br />CONSTRUCTION DOCUMENTS <br />03.24.2023 <br />DESCRIPTION <br />PRINCIPAL IN CHARGE <br />F. CAMPBELL <br />­­ ... I .... I ................................................ <br />PROJECT MANAGER <br />M. TORRES <br />............ I � ...... I ........ I ............ I ........ ­ .............. <br />ADVENT HEALTH <br />WELL 65+ <br />ZEPHYRHILLS <br />22-0328-01 <br />SANITARY WASTE <br />RENOVATION <br />__ - __ - ____ T7__F_ T _'__ 7­ -T __F_ I I �. I, . 1—, 11, � i I I , i - 7�7 � I- _]I --I T_T___.1 111 jj , hA i, I j I I I I I - ------ I- -H <br />I F_ - __ - __ ___T_ , F <br />