Laserfiche WebLink
32 min <br />(a) <br />Details <br />32 min <br />(C) <br />Sliding Door <br />32 min <br />(d) <br />Folding Door <br />DOORS & MANEUVERING CLEARANCES <br />32MIN <br />815 <br />(b) <br />Hinged Door <br />.E <br />E <br />18 min. 24 prefe�ed <br />455 <br />NOTE: x = 12 in (305 mm) if door has both a <br />closer and latch. \Ij <br />Front Approaches - Swinging Doors <br />54 min <br />32 min <br />815 <br />x E <br />]E <br />NOTE: x 36 in (915 mm) minimum if y 60 In NOTE: y 48in (1220 mm) minimum ifdoor has <br />(e) (1525 mm): x = 42 in (1063 mm) minimum if y both a latch and closer� <br />Mammum Doorway Depth 54 in (1370 mm) (b) <br />Hinge Side Approaches - Swinging Doors <br />Fig. 24 <br />Clear Doorway Width and Depth <br />x 24 min <br />610 24 min x <br />610 <br />E E <br />V <br />NOTE: y 54 in (1370 mm) minimum if door has NOTE: y 48 in (1220 mm) minimum if door has <br />closer. closer. <br />(c) <br />Latch Side Approaches - Swinging Dom <br />48 min <br />1220 <br />'A min <br />1370 <br />-c <br />E <br />E <br />(d) <br />Front Approach - Sliding Doors <br />and Folding Doors <br />(e) <br />Slide Side Approach - -Sliding Doors <br />and Folding Doors <br />B Min <br />4 122D <br />NOTE: All doors in alcoves <br />x <br />24 min <br />610 <br />shall comply with the clearances <br />for front approaches E <br />C� <br />L— <br />— — — — — — <br />— — — — — — <br />Latch Side Approach - Sliding Doors and Folding Doors <br />Fig. 26 <br />Fig. 25 <br />Two Hinged Doors in Series <br />Maneuveriing Clearances at Doors (Continued) <br />404 DOORS. DOORWAYS. AND GA ES <br />404.1 GENERAL, DOORS, DOORWAYS, AND GATES THAT ARE PART OF AN ACCESSIBLE ROUTE SHALL COMPLY WITH 404. <br />404.2.1 REVOLVING DOORS. GATES, AND TURNSTILES. REVOLVING DOORS, REVOLVING GATES, AND TURNSTILES SHALL NOT BE PART OF AN ACCESSIBLE ROUTE. <br />404.2.2 DOUBLE -LEAF DOORS AND GATES, AT LEAST ONE OF THE ACTIVE LEAVES OF DOORWAYS WITH TWO LEAVES SHALL COMPLY WITH 404.2.3 AND 404.2.4. <br />404.2.3 CLEAR WIDTH, DOOR OPENINGS SHALL PROVIDE A CLEAR WIDTH OF 32 INCHES (815 MM) MINIMUM. CLEAR OPENINGS OF DOORWAYS WITH SWINGING DOORS SHALL BE MEASURED BETWEEN THE FACE OF THE DOOR AND THE STOP, WITH THE DOOR <br />OPEN 90 DEGREES. OPENINGS MORE THAN 24 INCHES (610 MM) DEEP SHALL PROVIDE A CLEAR OPENING OF 36 INCHES (915 MM) MINIMUM. THERE SHALL BE NO PROJECTIONS IN TO THE REQUIRED CLEAR OPENING WIDTH LOWER THAN 34 INCHES (865 MM) <br />ABOVE THE FINISH FLOOR OR GROUND. PROJECTIONS INTO THE CLEAR OPENING WIDTH BETWEEN 34 INCHES (865 MM) AND 80 INCHES (2030 MM) ABOVE THE FINISH FLOOR OR GROUND SHALL NOT EXCEED 4 INCHES (100 MM). <br />EXCEPTIONS: <br />1. IN ALTERATIONS, A PROJECTION OF 5/8 INCH (16 MM) MAXIMUM INTO THE REQUIRED CLEAR WIDTH SHALL BE PERMITTED FOR THE LATCH SIDE STOP. <br />2. DOOR CLOSERS AND DOOR STOPS SHALL BE PERMITTED TO BE 78 INCHES (1980 MM) MINIMUM ABOVE THE FINISH FLOOR OR GROUND. <br />404.2.4 MANEUVERING CLEARANCES, MINIMUM MANEUVERING CLEARANCES AT DOORS AND GATES SHALL COMPLY WITH 404.2.4. MANEUVERING CLEARANCES SHALL EXTEND THE FULL WIDTH OFTHE DOORWAY AND THE REQUIRED LATCH SIDE OR HINGE SIDE <br />CLEARANCE. <br />EXCEPTION: ENTRY DOORS TO HOSPITAL PATIENT ROOMS SHALL NOT BE REQUIRED TO PROVIDE THE CLEARANCE BEYOND THE LATCH SIDE OF THE DOOR. <br />404.2.4.1 SWINGING DOORS AND GATES, SWINGING DOORS AND GATES SHALL HAVE MANEUVERING CLEARANCES COMPLYING WITH TABLE 404.2.4. 1. <br />404.2.4.2 DOORWAYS WITHOUT DOORS OR GATES, SLIDING DOORS. AND FOLDING DOORS, DOORWAYS LESS THAN 36 INCHES (915 MM) WIDE WITHOUT DOORS OR GATES, SLIDING DOORS, OR FOLDING DOORS SHALL HAVE MANEUVERING CLEARANCES <br />COMPLYING WITH TABLE 404.2.4.2. <br />404.2.4.3 RECESSED DOORS AND GATES, MANEUVERING CLEARANCES FOR FORWARD APPROACH SHALL BE PROVIDED WHEN ANY OBSTRUCTION WITHIN 18 INCHES (455 MM) OFTHE LATCH SIDE OF A DOORWAY PROJECTS MORETHAN 8 INCHES (205 MM) <br />BEYOND THE FACE OF THE DOOR, MEASURED PERPENDICULAR TO THE FACE OF THE DOOR OR GATE. <br />ADVISORY 404.2.4.3 RECESSED DOORS AND GATES. A DOOR CAN BE RECESSED DUE TO WALL THICKNESS OR BECAUSE OF THE PLACEMENT OF CASEWORK AND OTHER FIXED ELEMENTS ADJACENT TO THE DOORWAY. THIS PROVISION MUST BE APPLIED WHEREVER <br />DOORS ARE RECESSED. <br />404.2.5 THRESHOLDS, THRESHOLDS, IF PROVIDED AT DOORWAYS, SHALL BE 1/2 INCH (13 MM) HIGH MAXIMUM. RAISED THRESHOLDS AND CHANGES IN LEVEL AT DOORWAYS SHALL COMPLY WITH 302 AND 303. <br />EXCEPTION: EXISTING OR ALTERED THRESHOLDS 3/4 INCH (19 MM) HIGH MAXIMUM THAT HAVE A BEVELED EDGE ON EACH SIDE WITH A SLOPE NOT STEEPER THAN 1:2 SHALL NOT BE REQUIRED TO COMPLY WITH 404.2.5. <br />404.2.6 DOORS IN SERIES AND GATES IN SERIES, THE DISTANCE BETWEEN TWO HINGED OR PIVOTED DOORS IN SERIES AND GATES IN SERIES SHALL BE 48 INCHES (1220 MM) MINIMUM PLUS THE WIDTH OF DOORS OR GATES SWINGING INTO THE SPACE. <br />404.2.7 DOOR AND GATE HARDWARE, HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON DOORS AND GATES SHALL COMPLY WITH 309.4. OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34 INCHES (865 MM) MINIMUM AND 48 INCHES (1220 <br />MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. WHERE SLIDING DOORS ARE IN THE FULLY OPEN POSITION, OPERATING HARDWARE SHALL BE EXPOSED AND USABLE FROM BOTH SIDES. <br />EXCEPTIONS: <br />1. EXISTING LOCKS SHALL BE PERMITTED IN ANY LOCATION AT EXISTING GLAZED DOORS WITHOUT STILES, EXISTING OVERHEAD ROLLING DOORS OR GRILLES, AND SIMILAR EXISTING DOORS OR GRILLES THAT ARE DESIGNED WITH <br />LOCKS THAT ARE ACTIVATED ONLY AT THE TOP OR BOTTOM RAIL. <br />2. ACCESS GATES IN BARRIER WALLS AND FENCES PROTECTING POOLS, SPAS, AND HOT TUBS SHALL BE PERMITTED TO HAVE OPERABLE PARTS OF THE RELEASE OF LATCH ON SELF -LATCHING DEVICES AT 54 INCHES (1370 MM) MAXIMUM <br />ABOVE THE FINISH FLOOR OR GROUND PROVIDED THE SELF -LATCHING DEVICES ARE NOT ALSO SELF-LOCKING DEVICES AND OPERATED BY MEANS OF A KEY, ELECTRONIC OPENER, OR INTEGRAL COMBINATION LOCK. <br />ADVISORY 404.2.7. DOOR AND GATE HARDWARE. DOOR HARDWARE THAT CAN BE OPERATED WITH A CLOSED FIST OR A LOOSE GRIP ACCOMMODATES THE GREATEST RANGE OF USERS. HARDWARE THAT REQUIRES SIMULTANEOUS HAND AND FINGER <br />MOVEMENTS REQUIRE GREATER DEXTERITY AND COORDINATION, AND IS NOT RECOMMENDED. <br />404.2.8 CLOSING SPEED, DOOR AND GATE CLOSING SPEED SHALL COMPLY WITH 404.2.8. <br />404.2.8.1 DOOR CLOSERS AND GATE CLOSERS, DOOR CLOSERS AND GATE CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90 DEGREES, THE TIME REQUIRED TO MOVE THE DOOR TO A POSITION OF 12 DEGREES FROM THE LATCH IS 5 <br />SECONDS MINIMUM. <br />404.2.8.2 SPRING HINGES, DOOR AND GATE SPRING HINGES SHALL BE ADJUSTED SO THAT FROM THE OPEN POSITION OF 70 DEGREES, THE DOOR OR GATE SHALL MOVE TO THE CLOSED POSITION IN 1 .5 SECONDS MINIMUM. <br />404.2.9 DOOR AND GATE OPENING FORCE., FIRE DOORS SHALL HAVE A MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. THE FORCE FOR PUSHING OR PULLING OPEN A DOOR OR GATE OTHER THAN FIRE DOORS SHALL <br />BE AS FOLLOWS: <br />1. INTERIOR HINGED DOORS AND GATES: 5 POUNDS (22.2 N) MAXIMUM. <br />2. SLIDING OR FOLDING DOORS: 5 POUNDS (22.2 N) MAXIMUM. <br />3. EXTERIOR HINGED DOORS SHALL BE DESIGNED SO THAT SUCH DOORS CAN BE PUSHED OR PULLED OPEN WITH A FORCE NOT EXCEEDING 8.5 POUNDS (37.8 N). <br />THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD THE DOOR OR GATE IN A CLOSED POSITION. <br />ADVISORY 404.2.9 DOOR AND GATE OPENING FORCE. THE MAXIMUM FORCE PERTAINS TO THE CONTINUOUS APPLICATION OF FORCE NECESSARY TO FULLY OPEN A DOOR, NOT THE INITIAL FORCE NEEDED TO OVERCOME THE INERTIA OF THE DOOR. IT DOES NOT <br />APPLY TO THE FORCE REQUIRED TO RETRACT BOLTS OR TO DISENGAGE OTHER DEVICES USED TO KEEP THE DOOR IN A CLOSED POSITION. FLORIDA LAW, s.553.504(6),F.S., ESTABLISHES REQUIREMENTS FOR EXTERIOR DOOR OPENING FORCE. <br />404.2.8.2 SPRING HINGES. DOOR AND GATE SPRING HINGES SHALL BE ADJUSTED SO THAT FROM THE OPEN POSITION OF 70 DEGREES, THE DOOR OR GATE SHALL MOVE TO THE CLOSED POSITION IN 1 .5 SECONDS MINIMUM. <br />404.3 AUTOMATIC AND POWER -ASSISTED DOORS AND GATES, AUTOMATIC DOORS AND GATES SHALL COMPLY WITH 404.3. FULL -POWERED AUTOMATIC DOORS SHALL COMPLY WITH ANSI/BHMA A156.10 (INCORPORATED BY REFERENCE, SEE "REFERENCED <br />STANDARDS" IN CHAPTER 1.) LOW -ENERGY AND POWER -ASSISTED DOORS SHALL COMPLY WITH ANSI/BHMA A 156.19 (1997 OR 2002 EDITION) (INCORPORATED BY REFERENCE, SEE "REFERENCED STANDARDS" IN CHAPTER I). <br />404.3.1 CLEAR WIDTH, DOORWAYS SHALL PROVIDE A CLEAR OPENING OF 32 INCHES (815 MM) MINIMUM IN POWER -ON AND POWER -OFF MODE.THE MINIMUM CLEAR WIDTH FOR AUTOMATIC DOOR SYSTEMS IN A DOORWAY SHALL BE BASED ON THE CLEAR <br />OPENING PROVIDED BY ALL LEAVES IN THE OPEN POSITION. <br />404.3.2 MANEUVERING CLEARANCE, CLEARANCES AT POWER -ASSISTED DOORS AND GATES SHALL COMPLY WITH 404.2.4. CLEARANCES AT AUTOMATIC DOORS AND GATES WITHOUT STANDBY POWER AND SERVING AN ACCESSIBLE MEANS OF EGRESS SHALL <br />COMPLY WITH 404.2.4. <br />EXCEPTION: WHERE AUTOMATIC DOORS AND GATES REMAIN OPEN IN THE POWER -OFF CONDITION, COMPLIANCE WITH 404.2.4 SHALL NOT BE REQUIRED. <br />404.3.5 CONTROLS, MANUALLY OPERATED CONTROLS SHALL COMPLY WITH 309. THE CLEAR FLOOR SPACE ADJACENT TO THE CONTROL SHALL BE LOCATED BEYOND THE ARC OF THE DOOR SWING. <br />CAMPBELL +VAN DUSEN <br />ARCH ITECTU RE INTERIOR DESIGN <br />www.CVDstudio.com <br />CAMPBELL + VAN DUSEN Design Studio, LLC. <br />255 South Orange Avenue Suite # 1240 <br />Orlando, Florida 32801 <br />Phone: 407.930.6016 <br />FL. Lic. No. AROO 16053 <br />ARCHITECT OF RECORD <br />FRANK W. CAMPBELL AIA <br />FLLIC NO. AR0016053 <br />COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, <br />SEALED AND DATED BY THE ARCHITECT OF RECORD <br />COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, <br />SEALED AND DATED BY THE ENGINEER OF RECORD <br />_j <br />LL_ <br />ry <br />0 <br />F_ <br />CL <br />CL <br />LU <br />u <br />< <br />r) <br />U0 <br />> <br />Uj <br />Lij <br />_j <br />F— <br />F— <br />+ <br />L0 <br />Q <br />= <br />14C) <br />< <br />U-J <br />LU <br />> <br />I <br />I <br />0 <br />0 <br />LU <br />NO It <br />-,,o L6 <br />0!:� <br />CL <br />LU <br />r-4 <br />00 (V) <br />r-, (y) <br />CONSTRUCTION DOCUMENTS <br />03.24.2023 <br />DESCRIPTION <br />PRINCIPAL IN CHARGE <br />F. CAMPBELL <br />............................................................... .... <br />PROJECTMANAGER <br />M. TORRES <br />............................................................... .... <br />ADVENT HEALTH <br />WELL 65+ <br />ZEPHYRHILLS <br />22-0328-01 <br />NOTES <br />A0e1 <br />