Laserfiche WebLink
rio <br />ILW <br />LAI <br />CAMPBELL + VAN DUSEN <br />1ARCH I TECTU RE INTERIOR DESIGNI <br />www.CVDstudio.com <br />CAMPBELL + VAN DUSEN Design Studio, LLC. <br />255 South Orange Avenue Suite # 1240 <br />Orlando, Florida 32801 <br />Phone: 407.930.6016 <br />FL. Lic. No. AA26003339 <br />ARCHITECT OF RECORD <br />FRANK W. CAMPBELL AIA <br />FL LIC NO. AROO 16053 <br />COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, <br />SEALED AND DATED BY THE ARCHITECT OF RECORD <br />--- Do <br />I I I I liji, /I/ <br />SPANG4 `xe <br />6460 <br />IS of ji W <br />Lu - <br />% <br />'0� ssloo\- <br />Bryan G. Spangler, PE, <br />FL Reg. No. 64601 <br />COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, <br />SEALED AND DATED BY THE ENGINEER OF RECORD <br />OWN <br />__j <br />LL_ <br />0 <br />CL <br />LU <br />r-4 <br />U <br />Q <br />L-1) <br />LU <br />LU <br />Ce) <br />> <br />—1 <br />0 <br />co <br />F- <br />+ <br />LO <br />U <br />ELECTRICAL RENOVATION PLAN ROOF i_U <br />< <br />(D <br />LU <br />0 <br />> <br />1/8" = V-0" cz <br />C) <br />LU <br />ur*_�j <br />'0 Lo <br />I <br />OrP, <br />CL <br />< <br />3: <br />MI-1, <br />GENERAL NOTES: <br />1. REFER TO RISER DIAGRAM, ELECTRICAL DETAILS AND PANEL SCHEDULES FOR MORE INFORMATION. <br />2. PROVIDE NEW NAME ENGRAVED COVER PLATES INDICATING SUPPLY PANEL AND CIRCUIT NUMBER(S) FOR <br />ALL ELECTRICAL DEVICES IN THIS PROJECT. ENGRAVING SHALL BE RED FOR CRITICAL AND BLACK FOR <br />NORMAL CIRCUITS. <br />3. PROVIDE NEW UPDATED TYPED PANEL SCHEDULES FOR ALL PANELS USED IN THIS PROJECT. VERIFY <br />EXACT PANEL IDENTIFICATION WITH OWNER. PROVIDE NEW NAME ENGRAVED PLATES FOR ALL PANELS <br />NOT IDENTIFIED PROPERLY. VERIFY PRIOR TO ORDERING. <br />4. PROVIDE PHENOLIC NAMEPLATES ON ALL PANELBOARDS, SWITCHBOARDS, DISCONNECTS, <br />TRANSFORMERS, ETC, INDICATING DESIGNATION, CIRCUIT NUMBER(S), VOLTAGE AND WHERE UNIT IS FED <br />FROM. SECURE NAMEPLATES WITH AT LEAST TWO SCREWS OR RIVETS. CEMENTING AND ADHESIVE <br />INSTALLATION WILL NOT BE ACCEPTABLE. NAMEPLATES SHALL BE COLORED AS PER SPECIFICATIONS. <br />5. SCREENED DEVICES ARE EXISTING TO REMAIN DEVICES AND ARE SHOWN FOR REFERENCE ONLY. <br />6. EXISTING BRANCH CIRCUITS HAVE BEEN TAKEN FROM FIELD INVESTIGATION AND /OR ORIGINAL <br />DOCUMENTS AND SHOWN FOR THE CONVENIENCE OF THE ELECTRICAL CONTRACTOR AND SHALL NOT BE <br />CONSIDERED"AS-BUILT' CONDITION. BEFORE CONSTRUCTION BEGINS, ELECTRICAL CONTRACTOR SHALL <br />FIELD VERIFY ALL BRANCH CIRCUITS. <br />7. REFER TO FIRE ALARM NOTES, RISER AND SPECIFICATIONS FOR MORE INFORMATION. <br />RENOVATION PLAN NOTES <br />PROVIDE ANEW 60A, N-3R ENCLOSURE, 24OV, 30 HEAVY DUTY FUSED DISCONNECT <br />SWITCH. PROVIDE THREE (3) NEW RK5 FUSES SIZED PER MANUFACTURERS NAMEPLATE. <br />INFORMATION SHOWN WAS PROVIDED AT TIME OF DESIGN BY DIVISION 15, MCA 39AMPS, <br />MFS 45AMP. COORDINATE WITH DIVISION 15 DRAWINGS, DETAILS, EQUIPMENT LIST AND <br />SPECIFICATIONS PRIOR TO ORDERING. 344,146G. - 1-1/4-C. <br />PROVIDE A NEW WEATHER -RESISTANT LISTED GFCI RECEPTACLE. PROVIDE A <br />WEATHERPROOF IN -USE COVER. CONNECT PER MANUFACTURERS SPECIFICATIONS. <br />PROVIDE ANEW 30A, N-3R ENCLOSURE, 24OV, 30 HEAVY DUTY FUSED DISCONNECT <br />SWITCH. PROVIDE THREE (3) NEW FUSES SIZED PER MANUFACTURERS NAMEPLATE. <br />INFORMATION SHOWN WAS PROVIDED AT TIME OF DESIGN BY DIVISION 23, MCA 18AMPS, <br />MFS 30AMPS. COORDINATE WITH DIVISION 23 DRAWINGS, DETAILS, EQUIPMENT LIST AND <br />PROVIDE A FIRE ALARM SHUTDOWN RELAY, COMMAND MODULE AND DUCT DETECTOR, <br />REMOTE INDICATORrrEST STATION, CONNECT TO NEW FIRE ALARM SYSTEM. AHU SHALL <br />SHUTDOWN UPON ALARM. <br />CONSTRUCTION DOCUMENTS <br />03.24.2023 <br />PRINCIPAL IN CHARGE <br />F. CAMPBELL <br />.. ......................................... .......................... <br />PROJECT MANAGER <br />M. TORRES <br />................................................................... <br />ADVENT HEALTH <br />WELL 65+ <br />ZEPHYRHILLS <br />22-0328-01 <br />MEP CONSULTING <br />ELECTRICAL <br />ENGINEERS <br />SINCE 1977 <br />DEMOLITION PLAN - <br />FL REG NO. 3089 <br />ROOF <br />2016 ALDEN RD. <br />ORLANDO, FL <br />32803 <br />(407) 246-1688 <br />WWW.PEIFLA.COM <br />E392 <br />PEI PROJECT f <br />22121 <br />