Laserfiche WebLink
) <br />) <br />12 <br />4.01 <br />RAISED BANDS OR FOAM <br />PER COMMUNITY <br />SPECIFICATIONS <br />N o CJ /WEEP <br />N <br />- — — — - ' r I - <br />SCORED ❑❑ �❑ <br />STUCCO <br />s r [\ <br />N <br />N 4" <br />12 <br />15.0 <br />N <br />a <br />FIBEREGLASS SHINLGE INSTALLED <br />AS PER MANUFACTURER <br />SPECIFICATIONS <br />HEEL HGT. <br />HDR. <br />EXTERIOR <br />PLASTER ON <br />FRAME 00 <br />F- <br />FLASHING <br />_ 2ND <br />FIN FLR sic <br />T.O.M. <br />34 <br />---------------------------------- <br />— <br />----HDR. <br />oo�aoaoa <br />TEXTURED <br />CE IOUS <br />FINISHISH ON ON <br />CMU (TYP) <br />FIN FLR , <br />FRONT ELEVATION - A <br />SCALE: 1/4" = V-0" <br />9'-0" RIDGE VENT <br />12 <br />15.0 <br />FIBEREGLASS SHINLGE INSTALLED <br />AS PER MANUFACTURER <br />SPECIFICATIONS <br />S EXTERIOR <br />PLASTER ON <br />FRAME <br />CJ 25-SH CJ 12 <br />�4.0 <br />-------------------------------------- CJNVEEP-------------------------------------------I-----��s-- <br />---- -- -- ------------- ------------------------ <br />F <br />25-SH 25-SH <br />TEXTURED <br />CEMENTITIOUS <br />FINISH ON <br />CMU (TYP) <br />FIN FLR <br />LEFT ELEVATION - A <br />SCALE: 1/4" = V-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />txtenor uovering <br />R703.7 Exterior Plaster. <br />Installation of these materials shall be in compliance with ASTM <br />C926 and ASTM C1063, or ASTM C1787 and the provisions of <br />this code. <br />R703.7.1 Lath. <br />Lath and Lath attachments shall be of corrosion -resistant <br />materials. Expanded metal or woven wire lath shall be attached <br />with 1-1/2" long, 11 gage nails having <br />a 7/16" head, or 1-1/2" long, 16 gage staples, spaced in <br />accordance with ASTM C1063 or C1787, or as otherwise <br />approved. (Refer to sheet SN1 for the engineered method for <br />Lath attachment.) <br />Lathing Accessories <br />Attachments shall be of corrosion -resistant materials. <br />Wood Application: 16 Ga.x1-1/2" long (3/4"-1" crown) staples @ <br />6" O.C. vertically/horizontally into the framing members. <br />Masonry Application: Concrete stub nail, 3/8" (10 mm) head dia. <br />min. @ 6" O.C. vertically/horizontally or compatible adhesives, <br />exterior gun -grade, construction adhesive with 1" dabs @ 6" O.C. <br />or in a semi -continuous bead between the solid plaster base and <br />the solid portion of the key attachment flange. <br />Control Joints: Install control joint lathing accessories in <br />conformance with C1063. Lath shall not be continuous through <br />control joints, but shall be stopped and tied at each side. <br />All accessories shall be in accordance with the latest ASTM <br />C1063 & ASTM C1861. <br />R703.7.2 Plaster. <br />Plastering with cement plaster shall be not less than three coats <br />where applied over any type of code -approved lath and shall be <br />not less than two coats where directly applied over masonry, <br />concrete, clay brick, stone, or tile. If the plaster surface is <br />completely covered by veneer or other facing material or is <br />completely concealed, plaster application need be only two coats, <br />provided total thickness is as set in Table R702.1(1). <br />Cement plaster shall be in accordance with ASTM C926 and <br />material shall be in accordance with one of the types listed in <br />R703.7.2. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed as required in Section <br />R703.2 and, where applied over wood -based sheathing, shall <br />include a water -resistive vapor -permeable barrier with a <br />performance at least equivalent to two layers of Grade D paper. <br />The individual layers shall be installed independently such that <br />each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to <br />the water -resistive barrier is directed between the layers. <br />R703.2 Water -Resistive Barrier. <br />One layer of No. 15 asphalt felt, free from holes and breaks, <br />complying with ASTM D226 for Type 1 felt or other approved <br />water -resistive barrier shall be applied over studs or sheathing of <br />all exterior walls. No. 15 asphalt felt shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 <br />inches. Where joints occur, felt shall be lapped not less than 6 <br />inches. Other approved materials shall be installed in accordance <br />with the water -resistive barrier manufacturer's installation <br />instructions. The No. 15 asphalt felt or other approved <br />water -resistive barrier material shall be continuous to the top of <br />walls and terminated at penetrations and building appendages in <br />a manner to meet the requirements of the exterior wall envelope <br />as described in Section R703.1. <br />R703.4 Flashing. <br />Approved metal flashing, vinyl flashing, self -adhered membranes <br />and mechanically attached flexible flashing shall be applied <br />shingle -fashion or in accordance with the manufacturer's <br />instructions. Metal flashing shall be corrosion resistant. <br />Fluid -applied membranes used as flashing shall be applied in <br />accordance with the manufacturer's instructions. All flashing shall <br />be applied in a manner to prevent the entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. <br />Self -adhered membranes used as flashing shall comply with <br />AAMA 711. All exterior fenestration products shall be sealed at <br />the juncture with the building wall with a sealant complying with <br />AAMA 800 or ASTM C920 Class 25 Grade NS or greater for <br />proper joint expansion and contraction, ASTM C1281, AAMA 812, <br />or other approved standard as appropriate for the type of sealant. <br />Fluid -applied membranes used as flashing in exterior walls shall <br />comply with AAMA 714. The flashing shall extend to the surface <br />of the exterior wall finish. <br />Approved flashings shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry construction with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersection. <br />• At Built-in gutters. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />REV. 09.24.21 <br />7 O <br />CV <br />N x <br />c• ri <br />CIA L �' <br />IV^ <br />UJ = cc <br />L <br />J x. Q <br />- <br />_ o 0 <br />J L' `' <br />L.. <br />S t, UJ <br />101 lWl/t� <br />I."; <br />..-OASE c <br />(r • ��' ': <br />.� <br />Qq- 4-FL <br />tZ <br />,.•' <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W £ r <br />H o � cc at <br />5 <br />N N m N# LL <br />V •�-. � aC7 J , <br />co m it U. <br />C U LU <br />3 6. <br />N O u- a. - <br />y' - a <br />J ' U_ d S <br />Cr o <br />Z_ r m g <br />of-9 <br />IC '@ A OJ —� <br />m <br />W <br />Z <br />�Z Ix -JN 0 <br />IL IL <br />N <br />Z pV c630 <br />W �on <br />c9 <br />Z N <br />z � <br />Z n <br />J <br />a � <br />M <br />N Z W <br />f13 W W <br />� <br />V <br />0 W s <br />�N � w <br />w W <br />r— — E <br />r 8 <br />c o Y <br />CQ B <br />�Q <br />o <br />W <br />CIO <br />s <br />Ct p <br />was g¢ <br />�o <br />Za <br />Z <br />C E <br />N ro <br />a <br />L <br />°do <br />Wf <br />mp <br />.V <br />'0 <br />W Z <br />Z <br />C <br />N <br />o <br />< <br />az <br />W <br />5 <br />�0 <br />�w <br />�� <br />�'o <br />o <br />0 <br />w <br />M <br />a� <br />`S <br />0 <br />c <br />L.n <br />0 <br />°) <br />rn <br />c� <br />co <br />T <br />= <br />7— <br />Cr <br />m4-1 <br />to <br />r— <br />• <br />CO <br />'� N <br />N <br />Lei <br />T <br />Q N <br />T <br />ai <br />Em <br />Z. N <br />It y N <br />o <br />Z <br />Z <br />E r m <br />E w <br />C <br />,_ <br />a <br />U _J Q p <br />JOB <br />NO: 22-02364 <br />SCALE : AS NOTED <br />SHEET NO. <br />2.1 <br />