Laserfiche WebLink
7 <br />00 <br />12 <br />2ND — — — — — 4_01 _ter® <br />EXTERIOR <br />PLASTER ON <br />FRAME <br />FLASHING <br />TEXTURED <br />CEMENTITIOUS <br />FINISH ON <br />CMU (TYP) <br />6068 SGD <br />12 <br />—15.0 - <br />FIBEREGLASS SHINLGE INSTALLED <br />>�S-Z AS PER MANUFACTURER <br />SPECIFICATIONS <br />E E <br />CJ El <br />25-SH 25-SH <br />35-SH <br />A--1-------------------------- 1----F <br />REAR ELEVATION - A <br />SCALE: 1/4" = 1'-0" <br />9'-0" RIDGE VENT <br />FIBEREGLASS SHINLGE INSTALLED <br />AS PER MANUFACTURER <br />SPECIFICATIONS <br />12 <br />— 14.0 <br />— — — — — — — — — - <br />`— TEXTURED <br />FINISH ON IOUS RIGHT ELEVATION - A <br />CMU (TYP) <br />SCALE: 1/4" =1'-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />I Exterior Covering <br />R703.7 Exterior Plaster. <br />Installation of these materials shall be in compliance with ASTM <br />C926 and ASTM C1063, or ASTM C1787 and the provisions of <br />this code. <br />R703.7.1 Lath. <br />Lath and Lath attachments shall be of corrosion -resistant <br />materials. Expanded metal or woven wire lath shall be attached <br />with 1-1/2" long, 11 gage nails having <br />a 7/16" head, or 1-1/2" long, 16 gage staples, spaced in <br />accordance with ASTM C1063 or C1787, or as otherwise <br />approved. (Refer to sheet SN1 for the engineered method for <br />Lath attachment.) <br />Lathing Accessories <br />Attachments shall be of corrosion -resistant materials. <br />Wood Application: 16 Ga.x1-1/2" long (3/4"-1" crown) staples @ <br />6" O.C. vertically/horizontally into the framing members. <br />Masonry Application: Concrete stub nail, 3/8" (10 mm) head dia. <br />min. @ 6" O.C. vertically/horizontally or compatible adhesives, <br />exterior gun -grade, construction adhesive with 1" dabs @ 6" O.C. <br />or in a semi -continuous bead between the solid plaster base and <br />the solid portion of the key attachment flange. <br />Control Joints: Install control joint lathing accessories in <br />conformance with C1063. Lath shall not be continuous through <br />control joints, but shall be stopped and tied at each side. <br />All accessories shall be in accordance with the latest ASTM <br />C1063 & ASTM C1861. <br />R703.7.2 Plaster. <br />Plastering with cement plaster shall be not less than three coats <br />where applied over any type of code -approved lath and shall be <br />not less than two coats where directly applied over masonry, <br />concrete, clay brick, stone, or tile. If the plaster surface is <br />completely covered by veneer or other facing material or is <br />completely concealed, plaster application need be only two coats, <br />provided total thickness is as set in Table R702.1(1). <br />Cement plaster shall be in accordance with ASTM C926 and <br />material shall be in accordance with one of the types listed in <br />R703.7.2. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed as required in Section <br />R703.2 and, where applied over wood -based sheathing, shall <br />include a water -resistive vapor -permeable barrier with a <br />performance at least equivalent to two layers of Grade D paper. <br />The individual layers shall be installed independently such that <br />each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to <br />the water -resistive barrier is directed between the layers. <br />R703.2 Water -Resistive Barrier. <br />One layer of No. 15 asphalt felt, free from holes and breaks, <br />complying with ASTM D226 for Type 1 felt or other approved <br />water -resistive barrier shall be applied over studs or sheathing of <br />all exterior walls. No. 15 asphalt felt shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 <br />inches. Where joints occur, felt shall be lapped not less than 6 <br />inches. Other approved materials shall be installed in accordance <br />with the water -resistive barrier manufacturer's installation <br />instructions. The No. 15 asphalt felt or other approved <br />water -resistive barrier material shall be continuous to the top of <br />walls and terminated at penetrations and building appendages in <br />a manner to meet the requirements of the exterior wall envelope <br />as described in Section R703.1. <br />R703.4 Flashing. <br />Approved metal flashing, vinyl flashing, self -adhered membranes <br />and mechanically attached flexible flashing shall be applied <br />shingle -fashion or in accordance with the manufacturer's <br />instructions. Metal flashing shall be corrosion resistant. <br />Fluid -applied membranes used as flashing shall be applied in <br />accordance with the manufacturer's instructions. All flashing shall <br />be applied in a manner to prevent the entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. <br />Self -adhered membranes used as flashing shall comply with <br />AAMA 711. All exterior fenestration products shall be sealed at <br />the juncture with the building wall with a sealant complying with <br />AAMA 800 or ASTM C920 Class 25 Grade NS or greater for <br />proper joint expansion and contraction, ASTM C1281, AAMA 812, <br />or other approved standard as appropriate for the type of sealant. <br />Fluid -applied membranes used as flashing in exterior walls shall <br />comply with AAMA 714. The flashing shall extend to the surface <br />of the exterior wall finish. <br />Approved flashings shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry construction with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersection. <br />• At Built-in gutters. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />REV. 09.24.21 <br />N t <br />O <br />�. X <br />tk r1 <br />- <br />r t. V <br />D <br />LO <br />Q 'rr <br />< c L 4, <br />> ii � W <br />`���� P,. f.NSE,• �i <br />Q� <br />.' SAP ��'•,z <br />�N1�111l111ltt,1```���� <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within ftse <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />SS of <br />8 <br />= O N <br />v r LL <br />0).1 m J LL <br />INN in'Lo- P! w a <br />Pl 0 rL a S2 <br />, <br />LL LL a L <br />0 <br />Z_ tL� 0 <br />r7 f0 N <br />¢ <br />W tR�pjrn ¢aoo <br />C; <br />'1` <br />IL <br />Z W y O <br />N <br />LLL <br />ZpV c�:3rQn <br />W ❑0❑ <br />cD V <br />Z N <br />z <br />z � � <br />Wv) Z ' <br />0 <br />. <br />s <br />�- <br />O"' N <br />kn L-- <br />N <br />_w <br />Vi <br />w <br />sr <br />Q <br />m <br />" <br />E <br />E <br />o <br />� <br />�- <br />s° <br />�£ <br />z• <br />O <br />N E <br />U <br />z <br />O =O U <br />R Z <br />Z <br />Q) L <br />W <br />W CY <br />C <br />QLL <br />Z <br />i <br />8 <br />Z <br />yW <br />W <br />�3�E <br />wLL <br />J <br />w <br />all <br />st <br />°z1�4 <br />691 <br />�C <br />� L <br />0 <br />rn <br />E <br />C9 <br />co <br />r <br />� <br />r <br />r <br />W m <br />co <br />CO <br />'� N <br />O <br />N <br />LO <br />r <br />Q N <br />r <br />E <br />CN <br />N <br />z <br />T" d <br />w <br />0 <br />a. <br />Q p <br />JOB <br />NO: 22-02364 <br />SCALE : AS NOTED <br />SHEET NO. <br />2.2 <br />