SIMPSON HGAMI(
<br />W/
<br />(4)1/4"x1 1/2" SDS
<br />SCREWS
<br />TO BLOCKING & (2
<br />1/4"X2 3/4"
<br />TITEN TO CMU
<br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2) 16d NAILS EA. END.
<br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING AND
<br />FASTENERS. (MIN. FIRST 4 BAYS)
<br />SEE STRUCTURAL NOTES AND NAILING TOENAIL w/
<br />SCHEDULE FOR SHEATHING DETAIL-7 (2)16d NAILS—\
<br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END.
<br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING
<br />MAX. 9" AND FASTENERS. (MIN. FIRST 4 BAYS)
<br />UNSUPPORTED,
<br />IF >9" SEE 10/S5 BACKNAIL w/ (2)16d NAILS :�,
<br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. 2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END.
<br />MAX 9 SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING
<br />UNSUPPORTED, AND FASTENERS. (MIN. FIRST 4 BAYS) AND FASTENERS. (MIN. FIRST 4 BAYS)
<br />IF >9" SEE 1 O/S5 MAX. 9"
<br />BACKNAIL w/ (2) 16d NAILS UNSUPPORTED, BACKNAIL w/ (2)16d NAILS MAX 9
<br />SEE STRUCTURAL NOTES AND NAILING IF >9" SEE 10/S5 SEE STRUCTURAL NOTES AND UNSUPPORTED,
<br />SCHEDULE FOR SHEATHING DETAIL NAILING SCHEDULE FOR SHEATHING IF >9" SEE 10/S5
<br />45°±
<br />45' ± SEE STRUCTURAL
<br />NOTES AND NAILING
<br />2x4 CRO BRACE SCHEDULE FOR
<br />APPROX. 8" FROM SHEATHING DETAILY 2x4 KICKER 2x8 SYP#2 "L" BRACE TO
<br />EXTEND AT LEAST 90% OF
<br />RIDGE FASTENED AT "L" BRACE TO EXTEND 2x4 CROSS BRACE @ $ -0 0/C WEB LENGTH & NOTCH AT '
<br />EACH JOINT W/ (3) 10d AT LEAST 90% OF WEB APPROX. 8" FROM BOTTOM CHORD (SEE TABLE)
<br />& (2)10d TOE NAILS @ LENGTH (SEE TABLE) RIDGE FASTENED AT
<br />EA. END @ 48" O.C. •• EACH JOINT w/ 3 10d & SIMPSON H2.5A w/ (10) 8d
<br />2x8 P.T. GABLE TRUSS O FROM LEDGER TO
<br />SILL 1!2" CDX PLYWOOD OR END d TOE NAILS @ EA. .• BLOCKING
<br />7/16" OSB SHEATHING GYPSUM WALLBOARD
<br />ATTACHED W/ 10d GABLE TRUSS
<br />NAILS @ 6" O.C. EDGES 2"x4" PANEL BLOCKING @ 48" O.C. FOR THE FIRST
<br />AND 12" O.C. FIELD (4) ROWS OF TRUSSES FROM EA. END TYP. BOTTOM 1/2" CDX PLYWOOD OR 7/16"
<br />10dX3" @ 3" 0!C CORD ATTACHED W/ (2)16d TOENAILS OSB SHEATHING ATTACHED
<br />C.
<br />THROUGH CHORD 2"x4" LEDGER (MATCH BOTTOM CHORD EDGES AND 1wl 1 Od NAILS C2� O.C.OFIELD
<br />INTO 2"x6" P T PLATE SLOPE OF ADJACENT SCISSOR TRUSS)
<br />DETAIL
<br />2"x4" CROSS BRACE
<br />APPROX. 8" FROM
<br />\_ RIDGE FASTENED AT
<br />DOUBLE TOP PLATE EACH JOINT w/ (3) 1 Od /
<br />2x4 CROSS BRACE APPROX. 8" & (2)10d TOE NAILS @
<br />FROM RIDGE FASTENED AT EA. END / "L" BRACE TO EXTEND
<br />EACH JOINT w/ (3) 10d & (2)10d (NOT REQ'D WHEN AT LEAST 90% OF WEB
<br />TOE NAILS @ EA. END GABLE IS 4'-1" OR �\ /• LENGTH (SEE TABLE)
<br />2x FRAME WALL (SEE WALL SHORTER) �� GABLE TRUSS
<br />SECTION FOR SIZE & SPACING) 2x4 PANEL BLOCKING' 1/2" CDX PLYWOOD OR
<br />1/2" CDX PLYWOOD OR 7/16" @ 48" O/C FOR THE 7/16" OSB SHEATHING
<br />OSB SHEATHING ATTACHED FIRST (4) ROWS OF (2) 16d ATTACHED w/ 10d NAILS
<br />W/ 10d NAILS @ 6" O.C. EDGES TRUSSES FROM EA. NAILS @ 6" O.C. EDGES AND 12"
<br />AND 12" O.C. FIELD END TYP. TOP & �� O.C. FIELD
<br />2)16d NAILS BOTTOM ATTACHED \
<br />( W/ (2)16d TOENAILS 2x4 "T" ON TOP OF PANEL
<br />2x4 "T" ON TOP OF PANEL BLOCKING, 2"x6" P.T. SILL NOTCH "L" BRACE HERE 2x4 PANEL BLOCKING @ 48" O.C. FOR 2x BLOCKING BLOCKING, FASTEN WITH
<br />FASTEN WITH 10dx3" 4" O/C SPACED WEEP SCREED THE FIRST (4) ROWS OF TRUSSES 2x4 "T" ON TOP OF PANEL 1Odx3" @ 4" O/C
<br />@ INSTALLED PER MANUF. 1/2" x 8" "J" BOLT @ 48" O.C. WEEP SCREED FROM EA. END TYP. TOP & BOTTOM SIMPSON HGAIOKT w/ 4 1/4"x1 1/2" SDS SCREWS TO
<br />@ 48" O.C. BLOCKING, FASTEN WITH ( )
<br />SIMPSON META12 w/ (7)10dx1 1/2" NAILS AT 6'-0" INSTALLED PER MANUF. ATTACHED w/ (2)16d TOENAILS TRUSS & (4)1/4"x3" SDS SCREWS TO PLATES AT 24" O.C.
<br />MOISTURE BARRIER 10dx3" @ 4" 0/C
<br />1/2 x 8 J BOLT @ 32 O.C. MINIMUM 6 FROM O.C. MAX w/ MIN. 4" EMBEDMENT IN KO BLOCK -
<br />PLATE SPLICES w/ 3/16"x2" 0 PLATE WASHER MOISTURE BARRIER
<br />SIMPSON META12 w/ (7) ALTERNATE SIMPSON MSTAM24 w/ (7)10d NAILS
<br />NOTE: IF EMBEDDED 10dx1 1/2" NAILS AT EA. & (4)1/4"x2 1/4" TITEN @ T-0" O/C ALIGNED WITH
<br />STRAP MISSED VERTICAL SECTION TRUSS VERTICAL WEB (24" GABLE WEB SECTION 2
<br />WEB, USE MSTAM36 w/ (7) 1 O.C. MAX) w/ MIN. 4"
<br />1Od NAILS & (4)1/4"x2 1/4" SCALE: N.T.S. EMBEDMENT IN KO BLOCK
<br />TITEN ON OUTSIDE S5 SCALE: N.T.S. S5
<br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END.
<br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING
<br />REFER TO DETAIL J N N AND FASTENERS. (MIN. FIRST 4 BAYS)
<br />ON SHEET S5 FOR r r
<br />X-BRACING, AND TOP CO SEE STRUCTURAL
<br />CHORD BLOCKING N NOTES AND NAILING
<br />INFORMATION CO SCHEDULE FOR
<br />1 1 SHEATHING DETAIL BACKNAIL w/
<br />WOOD TRUSSES 1/ (2) 16d NAILS
<br />`� 00 00 2"x4" CROSS BRACE
<br />2x4 RAT RUN BRACING APPROX. 8" FROM
<br />AT 24" O.C. ON TOP OF RIDGE FASTENED AT
<br />EACH JOINT w/ (3)
<br />BOTT. CHORD FOR 4 10d & (2) 10d TOE
<br />TRUSS SPANS NAILS @ EA. END
<br />ATTACHED W/ 2 -16d
<br />AT EA. TRUSS JOINT 2) 2" x 4" LAMINATIONS W/ 1 ROW 2X4 PANEL BLOCKING
<br />xxi
<br />3 2" x 4" LAMINATIONS W/ 1 ROW LAMINATIONS N W/ Z R F ( () O O (3) 2 x 6 LA INA 0 S O ROWS 0 @ 48" O/C FOR THEM(2)16dNAILS2x4 BLOCKING @ 24" OF STAGGERED 10d COMMON WIRE NAILS OF STAGGERED 30d COMMON WIRE NAILS STAGGERED 30d COMMON WIRE NAILS FIRST 4 ROWS OF
<br />0/C w/ (2) 16d (D = 0.148", L = 3) OR EQUAL (D = 0.207' , L = 4 1/2') OR EQUAL (D = 0.207", L = 4 1/2") OR EQUAL ( )
<br />TOENAILS EA. END NOTES: TRUSSES FROM EA.
<br />@ 1) ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES 4) FOR 4-PLY, PROVIDE 1/4" DIA. x 5 1/2" LAG SCREWS OR EQUAL END TYP. TOP &
<br />BOTTOM ATTACHED
<br />MASONRY WALL OF THE COLUMN (SPACE AS SHOWN FOR 3-PLY) w/ (2)16d TOENAILS
<br />ARCHITECTURAL FINISH 2) ALL NAILS PENETRATE AT LEAST 3/4 OF THE THICKNESS 5) FOR 5-PLY, PROVIDE 1/4" DIA. x 7" LAG SCREWS OR EQUAL
<br />P A H N PLY
<br />2x4 BLOCKING 2x4 "T" BLOCKING
<br />@ 48" O.C. 16d NAIL
<br />"L" BRACE
<br />ATTACHED W/
<br />1Od NAILS @ 4"
<br />O.C. TYPICAL
<br />GABLE TRUSS WEB
<br />DOUBLE "L" BRACING DETAIL 5
<br />SCALE: N.T.S. S5
<br />2x4 "T" BLOCKING
<br />2x4 BLOCKING @
<br />48" O.C.
<br />"L" BRACE ATTACHED 16d NAIL
<br />W/ 10d NAILS @ 4" 0.C�
<br />TYPICAL
<br />GABLE TRUSS WEB —'
<br />SINGLE "L" BRACING DETAILS 6
<br />SCALE: N.T.S. 5
<br />DIAPHRAGM
<br />BLOCKING @
<br />48" 0/C GABLE TRUSS
<br />TRUSS VERTICAL
<br />2x4 LEDGER (MATCH BOTTOM CHORD DBL. TOP PLATE NAILS AATSIMPSONSP2 w/ (12)10d
<br />NAILS EACH STUD (2) 2"x8" "L" BRACE J
<br />SLOPE OF ADJACENT TRUSS) STUD WALL (SEE TYP. SEC.) FASTENED WITH (3)
<br />16d PER SIDE
<br />SECTION 3 SECTION 4 SCISSOR GABLE "T" BRACE
<br />SCALE: N.T.S. S5 SCALE: N.T.S. S5 REV. 06.08.22 AS PER HIB 91 SCALE: N.T.S. S5
<br />MAX. 9"
<br />UNSUPPORTED, 8d @ 6"O/C
<br />IF >9" SEE 10/S5 r WOOD TRUSSES
<br />"L" BRACE TO EXTEND
<br />AT LEAST 90% OF WEB
<br />LENGTH (SEE TABLE)
<br />-GABLE TRUSS
<br />-1/2" CDX PLYWOOD OR 7/16"
<br />OSB SHEATHING ATTACHED
<br />W/ 1Od NAILS @ 6" O.C. SIMPSON HGAMI OKTA w/ (4)
<br />E ES AND 12" O.C. FIELD 1/4"x1 1/2" SDS SCREWS TO
<br />JACK TRUSS BLOCKING & (4) 1/4"X2 3/4"
<br />SEE PLAN FOR TITEN TO CMU
<br />CONNECTION
<br />14�]
<br />OF THE LAST LAMINATION SPACE S SHOWN FOR 3- ) 2x4 "T" ON TOP OF PANEL I LL
<br />EXT. WALL CONN. 3) EACH 30d COMMON NAIL MAY BE REPLACED W/ (2) 16d 6) REFER TO NDS SECTION 15.3 FOR ADDITIONAL INFORMATION Odx3'BLOCKIN 4" FASTEN WITH [ 2x 12LOCKG TOENAILS/
<br />NON - LOAD BEARING LOCATION COMMON NAILS. (ONE INTO EACH OUTSIDE FACE OF
<br />D B.U.C., SAME NUMBER OF ROWS, SAME SPACING)
<br />SEE TYP. WALL SECTION FOR SCALE: 3/4"=1'-0" S5 TYPICAL NAILING SCHEDULES FOR BUILT-UP COLUMNS 8 SECTION g T
<br />ADDITIONAL INFORMATION. SCALE; N.T.S. S5 SCALE: N.T.S. S5
<br />11NIMUM 2x
<br />,ROSS BRACING
<br />SEE PLAN FOR
<br />OCATIONS)
<br />(2)16d PER
<br />JOINT
<br />f- CONTINUOUS BOTTOM CORD BRACING 2"x4" MI/N. SSEEEMM/S5
<br />CROSS BRACING DETAIL J
<br />SCALE: N.T.S.
<br />TOENAIL s
<br />(2)16d NA
<br />12"
<br />SH SCHEDULE
<br />,TTACHMENT
<br />? SYP BLK'G @ 16" O.C.
<br />I x 0.131"
<br />AILS EA. SIDE
<br />2x4 #2 SYP w/ 1 Od
<br />X0.131"@8"O.C.
<br />ALTERNATE NON -DROP
<br />GABLE END DETAIL 10
<br />SCALE: N.T.S. S5
<br />1 GABLE TRUSS
<br />S5
<br />"L" BRACE W/ 1 Od @ 4" O.C.
<br />12 (SEE SCHEDULE FOR SIZE
<br />AND LOCATION)
<br />6.9 MAX.
<br />S5
<br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION
<br />SCALE: N.T.S.
<br />PRE-ENGINEERED
<br />WOOD TRUSSES
<br />OVERLAP TRUSS BRACING
<br />AT LEAST TWO TRUSS SPACES
<br />`-MINIMUM (2)16d PER JOINT \-MINIMUM 2X4 TRUSS BRACING
<br />TRUSS BRACING OVERLAP DETAIL
<br />SCALE: N.T.S
<br />6" OVERLAP
<br />M
<br />S5
<br />"L" BRACE W/ 10d @ 4" O/C
<br />(SEE SCHEDULE FOR SIZE
<br />AND LOCATION)
<br />2 x 4 BLOCKING w/ (2)1 Od
<br />TOE NAILS AT EACH END @
<br />24" O/C (TYP)
<br />•
<br />a
<br />z
<br />UJI
<br />`,.BRACING w/ (3)10d x 3" AT
<br />EACH CONN. @ 24" O/C
<br />\-MOISTURE BARRIER
<br />-BOND BEAM
<br />MASONRY WALL
<br />ARCHITECTURAL FINISH
<br />EXT. WALL CONN. NON -LOAD
<br />BEARING LOCATIO(UNEVEN CLG.)
<br />SEE TYP. WALL SECTION FOR
<br />ADDITIONAL INFORMATION.
<br />SCALE: N.T.S.
<br />"L" BRACING REQUIREMENTS
<br />STUD NO (1) 2"x4" (U.N.O.) 2"X6" (U.N.O.)
<br />SPACING "L" BRACE "L" BRACE "L" BRACE
<br />24" 0'0" - T-0" T-O" - 6'-0" 6-0" & GREATER
<br />SCISSOR GABLE - (1) 2'W" #2 S.P.F. @ EACH VERTICAL AND
<br />(2) 2"x8" FULL HEIGHT @ DIAPHRAGM BLOCKING
<br />NOTE:
<br />1) "L" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES
<br />BRACE TO EXTEND FULL HEIGHT OF GABLE.
<br />2) "L" BRACE TO BE FASTENED TO GABLE STUD WITH 10dx3" NAILS @ 4" O/C.
<br />3) SEE 6/S5 FOR MORE INFO.
<br />SIMPSON HGA10KTw/ (4) 1/4"x1 1/2" SDS
<br />SCREWS TO TRUSS & (4) 1/4"x3" SDS SCREWS
<br />TO PLATES (TYP.)
<br />—wiv i. ocnnuva -
<br />GABLE END BRACING DETAIL SCALE:3/4"=1'-0"
<br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION
<br />SIMPSON SP2 w/ (12)
<br />10d NAILS AT EACH
<br />STUD
<br />HIP FRAMING REFERENCE PLAN
<br />20'-0" MAX 20'-0" MAX
<br />"X" BRACE SEE DET. J/S5 -, CONTINUOUS BOTTO CHORD BRACING 2X4 MIN.
<br />Lmq
<br />Ll MM
<br />cc
<br />MM
<br />NOTE: /-TOP CHORD 2X4 #2 SYP BRACING
<br />1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING @ 16" O.C. MAX. FOR FIRST (4)
<br />CUT SHEETS FOR ADDITIONAL PERMANENT BRACING BAYS
<br />THAT MY BE REQUIRED ZBOTTOM CHORD GABLE END BRACING
<br />2) '7 BRACING MAY BE USED IN PLACE OF PERMANENT @ 4'-0" O.C. MAX. FOR FIRST (4) BAYS
<br />BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB.
<br />REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN
<br />AS PER BCSI
<br />SCISSOR TRUSS
<br />SCISSOR TRUSS
<br />W/ DROP CEILING BRACING DETAIL
<br />SCALE: N.T.S.
<br />2X4 BRACING @ 48" O.C. CONTINUOUS TO
<br />FIXED LOCATION ATTACHED W/ (2)10d AT
<br />EA. TRUSS (NOTE: BRACING MAY BE
<br />PLACED ON EITHER TOP OR BOTTOM OF
<br />THE BOTTOM CORD)
<br />COSMETIC DROP CEILING FRAMING
<br />MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS
<br />SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION
<br />WOOD FRAMED GABLE END BRACING DETAIL
<br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S.
<br />FOR WIND SPEED SPECIFICATION
<br />e•�
<br />c1%j
<br />cl�4
<br />c�
<br />CD
<br />c
<br />L.0
<br />as LU
<br />> W
<br />i L
<br />U Q. Lam- O
<br />c �ae�N
<br />•sz N Y
<br />32 W
<br />� = _= C"
<br />�E=
<br />�+ via
<br />� � ro
<br />3
<br />� .!!! �
<br />CU
<br />a ,
<br />Ni7..-in
<br />C
<br />It
<br />_^� N SE
<br />w Ji
<br />.. G�
<br />J�' •... "� E a Q � �\`N
<br />�d6lt€till"
<br />To the best of the Engineers knowledge, information and belief,
<br />the structural plans and specifications contained within these
<br />drawings comply with the 2020 Florida Building Code -
<br />Residential 7th Edition. Engineers signature and seal is only for
<br />the structural engineering portions of the drawing pages bearing
<br />Engineers signature and seal.
<br />W
<br />:) h a E
<br />IMAM
<br />4MEE
<br />O N
<br />b' G
<br />at � N
<br />J
<br />�j 6J "r
<br />�i C 525 LL W
<br />.� °
<br />= -o a Y
<br />Z ��
<br />Y�o`_ t
<br />�. IL w _ N $
<br />W U5 Cj m w
<br />y co M Z ¢ J
<br />a N O U v
<br />U w
<br />❑ El
<br />V M M
<br />� N M
<br />o
<br />zco
<br />�QQ
<br />d v
<br />o- n
<br />U)
<br />N z
<br />Q) o
<br />W
<br />U � a
<br />OW c
<br />Ln �y N
<br />M U r6
<br />LU
<br />Ij M
<br />, = L z
<br />U o •
<br />Q N `=
<br />W
<br />Q Z
<br />M p 5> C
<br />J �
<br />ce
<br />LL zo >m
<br />a aN
<br />CL
<br />o oLL z©
<br />E 8 u oa
<br />(0 CIO
<br />�to Do
<br />a 0. 0a p�
<br />Q
<br />h wa ww
<br />r
<br />O
<br />a GU 0,
<br />z 6 <w
<br />z
<br />Z
<br />W w a
<br />�� ww
<br />oz r2�
<br />Mja
<br />o M11
<br />c 0
<br />0
<br />> (O
<br />LO
<br />^. '' hh
<br />m
<br />Q u!
<br />N N
<br />OCo
<br />ca
<br />Y — T
<br />m U) m ^
<br />L N
<br />}I C
<br />T Q '�O N �
<br /><C I )
<br />-� N Ln
<br />C3� N r
<br />1_ L0 T
<br />T
<br />E E M Z
<br />CU � N
<br />z E 0
<br />r_
<br />a U Q p
<br />JOB NO: 23-00522
<br />SCALE : AS NOTED
<br />SHEET NO.
<br />S5
<br />FT I_- fl I tq I I III I
<br />I �T il'l ii 7i� J. iT97r 3 - I
<br />DETAIL
<br />2"x4" CROSS BRACE
<br />APPROX. 8" FROM
<br />\_ RIDGE FASTENED AT
<br />DOUBLE TOP PLATE EACH JOINT w/ (3) 1 Od /
<br />2x4 CROSS BRACE APPROX. 8" & (2)10d TOE NAILS @
<br />FROM RIDGE FASTENED AT EA. END / "L" BRACE TO EXTEND
<br />EACH JOINT w/ (3) 10d & (2)10d (NOT REQ'D WHEN AT LEAST 90% OF WEB
<br />TOE NAILS @ EA. END GABLE IS 4'-1" OR �\ /• LENGTH (SEE TABLE)
<br />2x FRAME WALL (SEE WALL SHORTER) �� GABLE TRUSS
<br />SECTION FOR SIZE & SPACING) 2x4 PANEL BLOCKING' 1/2" CDX PLYWOOD OR
<br />1/2" CDX PLYWOOD OR 7/16" @ 48" O/C FOR THE 7/16" OSB SHEATHING
<br />OSB SHEATHING ATTACHED FIRST (4) ROWS OF (2) 16d ATTACHED w/ 10d NAILS
<br />W/ 10d NAILS @ 6" O.C. EDGES TRUSSES FROM EA. NAILS @ 6" O.C. EDGES AND 12"
<br />AND 12" O.C. FIELD END TYP. TOP & �� O.C. FIELD
<br />2)16d NAILS BOTTOM ATTACHED \
<br />( W/ (2)16d TOENAILS 2x4 "T" ON TOP OF PANEL
<br />2x4 "T" ON TOP OF PANEL BLOCKING, 2"x6" P.T. SILL NOTCH "L" BRACE HERE 2x4 PANEL BLOCKING @ 48" O.C. FOR 2x BLOCKING BLOCKING, FASTEN WITH
<br />FASTEN WITH 10dx3" 4" O/C SPACED WEEP SCREED THE FIRST (4) ROWS OF TRUSSES 2x4 "T" ON TOP OF PANEL 1Odx3" @ 4" O/C
<br />@ INSTALLED PER MANUF. 1/2" x 8" "J" BOLT @ 48" O.C. WEEP SCREED FROM EA. END TYP. TOP & BOTTOM SIMPSON HGAIOKT w/ 4 1/4"x1 1/2" SDS SCREWS TO
<br />@ 48" O.C. BLOCKING, FASTEN WITH ( )
<br />SIMPSON META12 w/ (7)10dx1 1/2" NAILS AT 6'-0" INSTALLED PER MANUF. ATTACHED w/ (2)16d TOENAILS TRUSS & (4)1/4"x3" SDS SCREWS TO PLATES AT 24" O.C.
<br />MOISTURE BARRIER 10dx3" @ 4" 0/C
<br />1/2 x 8 J BOLT @ 32 O.C. MINIMUM 6 FROM O.C. MAX w/ MIN. 4" EMBEDMENT IN KO BLOCK -
<br />PLATE SPLICES w/ 3/16"x2" 0 PLATE WASHER MOISTURE BARRIER
<br />SIMPSON META12 w/ (7) ALTERNATE SIMPSON MSTAM24 w/ (7)10d NAILS
<br />NOTE: IF EMBEDDED 10dx1 1/2" NAILS AT EA. & (4)1/4"x2 1/4" TITEN @ T-0" O/C ALIGNED WITH
<br />STRAP MISSED VERTICAL SECTION TRUSS VERTICAL WEB (24" GABLE WEB SECTION 2
<br />WEB, USE MSTAM36 w/ (7) 1 O.C. MAX) w/ MIN. 4"
<br />1Od NAILS & (4)1/4"x2 1/4" SCALE: N.T.S. EMBEDMENT IN KO BLOCK
<br />TITEN ON OUTSIDE S5 SCALE: N.T.S. S5
<br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END.
<br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING
<br />REFER TO DETAIL J N N AND FASTENERS. (MIN. FIRST 4 BAYS)
<br />ON SHEET S5 FOR r r
<br />X-BRACING, AND TOP CO SEE STRUCTURAL
<br />CHORD BLOCKING N NOTES AND NAILING
<br />INFORMATION CO SCHEDULE FOR
<br />1 1 SHEATHING DETAIL BACKNAIL w/
<br />WOOD TRUSSES 1/ (2) 16d NAILS
<br />`� 00 00 2"x4" CROSS BRACE
<br />2x4 RAT RUN BRACING APPROX. 8" FROM
<br />AT 24" O.C. ON TOP OF RIDGE FASTENED AT
<br />EACH JOINT w/ (3)
<br />BOTT. CHORD FOR 4 10d & (2) 10d TOE
<br />TRUSS SPANS NAILS @ EA. END
<br />ATTACHED W/ 2 -16d
<br />AT EA. TRUSS JOINT 2) 2" x 4" LAMINATIONS W/ 1 ROW 2X4 PANEL BLOCKING
<br />xxi
<br />3 2" x 4" LAMINATIONS W/ 1 ROW LAMINATIONS N W/ Z R F ( () O O (3) 2 x 6 LA INA 0 S O ROWS 0 @ 48" O/C FOR THEM(2)16dNAILS2x4 BLOCKING @ 24" OF STAGGERED 10d COMMON WIRE NAILS OF STAGGERED 30d COMMON WIRE NAILS STAGGERED 30d COMMON WIRE NAILS FIRST 4 ROWS OF
<br />0/C w/ (2) 16d (D = 0.148", L = 3) OR EQUAL (D = 0.207' , L = 4 1/2') OR EQUAL (D = 0.207", L = 4 1/2") OR EQUAL ( )
<br />TOENAILS EA. END NOTES: TRUSSES FROM EA.
<br />@ 1) ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES 4) FOR 4-PLY, PROVIDE 1/4" DIA. x 5 1/2" LAG SCREWS OR EQUAL END TYP. TOP &
<br />BOTTOM ATTACHED
<br />MASONRY WALL OF THE COLUMN (SPACE AS SHOWN FOR 3-PLY) w/ (2)16d TOENAILS
<br />ARCHITECTURAL FINISH 2) ALL NAILS PENETRATE AT LEAST 3/4 OF THE THICKNESS 5) FOR 5-PLY, PROVIDE 1/4" DIA. x 7" LAG SCREWS OR EQUAL
<br />P A H N PLY
<br />2x4 BLOCKING 2x4 "T" BLOCKING
<br />@ 48" O.C. 16d NAIL
<br />"L" BRACE
<br />ATTACHED W/
<br />1Od NAILS @ 4"
<br />O.C. TYPICAL
<br />GABLE TRUSS WEB
<br />DOUBLE "L" BRACING DETAIL 5
<br />SCALE: N.T.S. S5
<br />2x4 "T" BLOCKING
<br />2x4 BLOCKING @
<br />48" O.C.
<br />"L" BRACE ATTACHED 16d NAIL
<br />W/ 10d NAILS @ 4" 0.C�
<br />TYPICAL
<br />GABLE TRUSS WEB —'
<br />SINGLE "L" BRACING DETAILS 6
<br />SCALE: N.T.S. 5
<br />DIAPHRAGM
<br />BLOCKING @
<br />48" 0/C GABLE TRUSS
<br />TRUSS VERTICAL
<br />2x4 LEDGER (MATCH BOTTOM CHORD DBL. TOP PLATE NAILS AATSIMPSONSP2 w/ (12)10d
<br />NAILS EACH STUD (2) 2"x8" "L" BRACE J
<br />SLOPE OF ADJACENT TRUSS) STUD WALL (SEE TYP. SEC.) FASTENED WITH (3)
<br />16d PER SIDE
<br />SECTION 3 SECTION 4 SCISSOR GABLE "T" BRACE
<br />SCALE: N.T.S. S5 SCALE: N.T.S. S5 REV. 06.08.22 AS PER HIB 91 SCALE: N.T.S. S5
<br />MAX. 9"
<br />UNSUPPORTED, 8d @ 6"O/C
<br />IF >9" SEE 10/S5 r WOOD TRUSSES
<br />"L" BRACE TO EXTEND
<br />AT LEAST 90% OF WEB
<br />LENGTH (SEE TABLE)
<br />-GABLE TRUSS
<br />-1/2" CDX PLYWOOD OR 7/16"
<br />OSB SHEATHING ATTACHED
<br />W/ 1Od NAILS @ 6" O.C. SIMPSON HGAMI OKTA w/ (4)
<br />E ES AND 12" O.C. FIELD 1/4"x1 1/2" SDS SCREWS TO
<br />JACK TRUSS BLOCKING & (4) 1/4"X2 3/4"
<br />SEE PLAN FOR TITEN TO CMU
<br />CONNECTION
<br />14�]
<br />OF THE LAST LAMINATION SPACE S SHOWN FOR 3- ) 2x4 "T" ON TOP OF PANEL I LL
<br />EXT. WALL CONN. 3) EACH 30d COMMON NAIL MAY BE REPLACED W/ (2) 16d 6) REFER TO NDS SECTION 15.3 FOR ADDITIONAL INFORMATION Odx3'BLOCKIN 4" FASTEN WITH [ 2x 12LOCKG TOENAILS/
<br />NON - LOAD BEARING LOCATION COMMON NAILS. (ONE INTO EACH OUTSIDE FACE OF
<br />D B.U.C., SAME NUMBER OF ROWS, SAME SPACING)
<br />SEE TYP. WALL SECTION FOR SCALE: 3/4"=1'-0" S5 TYPICAL NAILING SCHEDULES FOR BUILT-UP COLUMNS 8 SECTION g T
<br />ADDITIONAL INFORMATION. SCALE; N.T.S. S5 SCALE: N.T.S. S5
<br />11NIMUM 2x
<br />,ROSS BRACING
<br />SEE PLAN FOR
<br />OCATIONS)
<br />(2)16d PER
<br />JOINT
<br />f- CONTINUOUS BOTTOM CORD BRACING 2"x4" MI/N. SSEEEMM/S5
<br />CROSS BRACING DETAIL J
<br />SCALE: N.T.S.
<br />TOENAIL s
<br />(2)16d NA
<br />12"
<br />SH SCHEDULE
<br />,TTACHMENT
<br />? SYP BLK'G @ 16" O.C.
<br />I x 0.131"
<br />AILS EA. SIDE
<br />2x4 #2 SYP w/ 1 Od
<br />X0.131"@8"O.C.
<br />ALTERNATE NON -DROP
<br />GABLE END DETAIL 10
<br />SCALE: N.T.S. S5
<br />1 GABLE TRUSS
<br />S5
<br />"L" BRACE W/ 1 Od @ 4" O.C.
<br />12 (SEE SCHEDULE FOR SIZE
<br />AND LOCATION)
<br />6.9 MAX.
<br />S5
<br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION
<br />SCALE: N.T.S.
<br />PRE-ENGINEERED
<br />WOOD TRUSSES
<br />OVERLAP TRUSS BRACING
<br />AT LEAST TWO TRUSS SPACES
<br />`-MINIMUM (2)16d PER JOINT \-MINIMUM 2X4 TRUSS BRACING
<br />TRUSS BRACING OVERLAP DETAIL
<br />SCALE: N.T.S
<br />6" OVERLAP
<br />M
<br />S5
<br />"L" BRACE W/ 10d @ 4" O/C
<br />(SEE SCHEDULE FOR SIZE
<br />AND LOCATION)
<br />2 x 4 BLOCKING w/ (2)1 Od
<br />TOE NAILS AT EACH END @
<br />24" O/C (TYP)
<br />•
<br />a
<br />z
<br />UJI
<br />`,.BRACING w/ (3)10d x 3" AT
<br />EACH CONN. @ 24" O/C
<br />\-MOISTURE BARRIER
<br />-BOND BEAM
<br />MASONRY WALL
<br />ARCHITECTURAL FINISH
<br />EXT. WALL CONN. NON -LOAD
<br />BEARING LOCATIO(UNEVEN CLG.)
<br />SEE TYP. WALL SECTION FOR
<br />ADDITIONAL INFORMATION.
<br />SCALE: N.T.S.
<br />"L" BRACING REQUIREMENTS
<br />STUD NO (1) 2"x4" (U.N.O.) 2"X6" (U.N.O.)
<br />SPACING "L" BRACE "L" BRACE "L" BRACE
<br />24" 0'0" - T-0" T-O" - 6'-0" 6-0" & GREATER
<br />SCISSOR GABLE - (1) 2'W" #2 S.P.F. @ EACH VERTICAL AND
<br />(2) 2"x8" FULL HEIGHT @ DIAPHRAGM BLOCKING
<br />NOTE:
<br />1) "L" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES
<br />BRACE TO EXTEND FULL HEIGHT OF GABLE.
<br />2) "L" BRACE TO BE FASTENED TO GABLE STUD WITH 10dx3" NAILS @ 4" O/C.
<br />3) SEE 6/S5 FOR MORE INFO.
<br />SIMPSON HGA10KTw/ (4) 1/4"x1 1/2" SDS
<br />SCREWS TO TRUSS & (4) 1/4"x3" SDS SCREWS
<br />TO PLATES (TYP.)
<br />—wiv i. ocnnuva -
<br />GABLE END BRACING DETAIL SCALE:3/4"=1'-0"
<br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION
<br />SIMPSON SP2 w/ (12)
<br />10d NAILS AT EACH
<br />STUD
<br />HIP FRAMING REFERENCE PLAN
<br />20'-0" MAX 20'-0" MAX
<br />"X" BRACE SEE DET. J/S5 -, CONTINUOUS BOTTO CHORD BRACING 2X4 MIN.
<br />Lmq
<br />Ll MM
<br />cc
<br />MM
<br />NOTE: /-TOP CHORD 2X4 #2 SYP BRACING
<br />1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING @ 16" O.C. MAX. FOR FIRST (4)
<br />CUT SHEETS FOR ADDITIONAL PERMANENT BRACING BAYS
<br />THAT MY BE REQUIRED ZBOTTOM CHORD GABLE END BRACING
<br />2) '7 BRACING MAY BE USED IN PLACE OF PERMANENT @ 4'-0" O.C. MAX. FOR FIRST (4) BAYS
<br />BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB.
<br />REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN
<br />AS PER BCSI
<br />SCISSOR TRUSS
<br />SCISSOR TRUSS
<br />W/ DROP CEILING BRACING DETAIL
<br />SCALE: N.T.S.
<br />2X4 BRACING @ 48" O.C. CONTINUOUS TO
<br />FIXED LOCATION ATTACHED W/ (2)10d AT
<br />EA. TRUSS (NOTE: BRACING MAY BE
<br />PLACED ON EITHER TOP OR BOTTOM OF
<br />THE BOTTOM CORD)
<br />COSMETIC DROP CEILING FRAMING
<br />MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS
<br />SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION
<br />WOOD FRAMED GABLE END BRACING DETAIL
<br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S.
<br />FOR WIND SPEED SPECIFICATION
<br />e•�
<br />c1%j
<br />cl�4
<br />c�
<br />CD
<br />c
<br />L.0
<br />as LU
<br />> W
<br />i L
<br />U Q. Lam- O
<br />c �ae�N
<br />•sz N Y
<br />32 W
<br />� = _= C"
<br />�E=
<br />�+ via
<br />� � ro
<br />3
<br />� .!!! �
<br />CU
<br />a ,
<br />Ni7..-in
<br />C
<br />It
<br />_^� N SE
<br />w Ji
<br />.. G�
<br />J�' •... "� E a Q � �\`N
<br />�d6lt€till"
<br />To the best of the Engineers knowledge, information and belief,
<br />the structural plans and specifications contained within these
<br />drawings comply with the 2020 Florida Building Code -
<br />Residential 7th Edition. Engineers signature and seal is only for
<br />the structural engineering portions of the drawing pages bearing
<br />Engineers signature and seal.
<br />W
<br />:) h a E
<br />IMAM
<br />4MEE
<br />O N
<br />b' G
<br />at � N
<br />J
<br />�j 6J "r
<br />�i C 525 LL W
<br />.� °
<br />= -o a Y
<br />Z ��
<br />Y�o`_ t
<br />�. IL w _ N $
<br />W U5 Cj m w
<br />y co M Z ¢ J
<br />a N O U v
<br />U w
<br />❑ El
<br />V M M
<br />� N M
<br />o
<br />zco
<br />�QQ
<br />d v
<br />o- n
<br />U)
<br />N z
<br />Q) o
<br />W
<br />U � a
<br />OW c
<br />Ln �y N
<br />M U r6
<br />LU
<br />Ij M
<br />, = L z
<br />U o •
<br />Q N `=
<br />W
<br />Q Z
<br />M p 5> C
<br />J �
<br />ce
<br />LL zo >m
<br />a aN
<br />CL
<br />o oLL z©
<br />E 8 u oa
<br />(0 CIO
<br />�to Do
<br />a 0. 0a p�
<br />Q
<br />h wa ww
<br />r
<br />O
<br />a GU 0,
<br />z 6 <w
<br />z
<br />Z
<br />W w a
<br />�� ww
<br />oz r2�
<br />Mja
<br />o M11
<br />c 0
<br />0
<br />> (O
<br />LO
<br />^. '' hh
<br />m
<br />Q u!
<br />N N
<br />OCo
<br />ca
<br />Y — T
<br />m U) m ^
<br />L N
<br />}I C
<br />T Q '�O N �
<br /><C I )
<br />-� N Ln
<br />C3� N r
<br />1_ L0 T
<br />T
<br />E E M Z
<br />CU � N
<br />z E 0
<br />r_
<br />a U Q p
<br />JOB NO: 23-00522
<br />SCALE : AS NOTED
<br />SHEET NO.
<br />S5
<br />FT I_- fl I tq I I III I
<br />I �T il'l ii 7i� J. iT97r 3 - I
<br />2x4 "T" ON TOP OF PANEL BLOCKING, 2"x6" P.T. SILL NOTCH "L" BRACE HERE 2x4 PANEL BLOCKING @ 48" O.C. FOR 2x BLOCKING BLOCKING, FASTEN WITH
<br />FASTEN WITH 10dx3" 4" O/C SPACED WEEP SCREED THE FIRST (4) ROWS OF TRUSSES 2x4 "T" ON TOP OF PANEL 1Odx3" @ 4" O/C
<br />@ INSTALLED PER MANUF. 1/2" x 8" "J" BOLT @ 48" O.C. WEEP SCREED FROM EA. END TYP. TOP & BOTTOM SIMPSON HGAIOKT w/ 4 1/4"x1 1/2" SDS SCREWS TO
<br />@ 48" O.C. BLOCKING, FASTEN WITH ( )
<br />SIMPSON META12 w/ (7)10dx1 1/2" NAILS AT 6'-0" INSTALLED PER MANUF. ATTACHED w/ (2)16d TOENAILS TRUSS & (4)1/4"x3" SDS SCREWS TO PLATES AT 24" O.C.
<br />MOISTURE BARRIER 10dx3" @ 4" 0/C
<br />1/2 x 8 J BOLT @ 32 O.C. MINIMUM 6 FROM O.C. MAX w/ MIN. 4" EMBEDMENT IN KO BLOCK -
<br />PLATE SPLICES w/ 3/16"x2" 0 PLATE WASHER MOISTURE BARRIER
<br />SIMPSON META12 w/ (7) ALTERNATE SIMPSON MSTAM24 w/ (7)10d NAILS
<br />NOTE: IF EMBEDDED 10dx1 1/2" NAILS AT EA. & (4)1/4"x2 1/4" TITEN @ T-0" O/C ALIGNED WITH
<br />STRAP MISSED VERTICAL SECTION TRUSS VERTICAL WEB (24" GABLE WEB SECTION 2
<br />WEB, USE MSTAM36 w/ (7) 1 O.C. MAX) w/ MIN. 4"
<br />1Od NAILS & (4)1/4"x2 1/4" SCALE: N.T.S. EMBEDMENT IN KO BLOCK
<br />TITEN ON OUTSIDE S5 SCALE: N.T.S. S5
<br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END.
<br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING
<br />REFER TO DETAIL J N N AND FASTENERS. (MIN. FIRST 4 BAYS)
<br />ON SHEET S5 FOR r r
<br />X-BRACING, AND TOP CO SEE STRUCTURAL
<br />CHORD BLOCKING N NOTES AND NAILING
<br />INFORMATION CO SCHEDULE FOR
<br />1 1 SHEATHING DETAIL BACKNAIL w/
<br />WOOD TRUSSES 1/ (2) 16d NAILS
<br />`� 00 00 2"x4" CROSS BRACE
<br />2x4 RAT RUN BRACING APPROX. 8" FROM
<br />AT 24" O.C. ON TOP OF RIDGE FASTENED AT
<br />EACH JOINT w/ (3)
<br />BOTT. CHORD FOR 4 10d & (2) 10d TOE
<br />TRUSS SPANS NAILS @ EA. END
<br />ATTACHED W/ 2 -16d
<br />AT EA. TRUSS JOINT 2) 2" x 4" LAMINATIONS W/ 1 ROW 2X4 PANEL BLOCKING
<br />xxi
<br />3 2" x 4" LAMINATIONS W/ 1 ROW LAMINATIONS N W/ Z R F ( () O O (3) 2 x 6 LA INA 0 S O ROWS 0 @ 48" O/C FOR THEM(2)16dNAILS2x4 BLOCKING @ 24" OF STAGGERED 10d COMMON WIRE NAILS OF STAGGERED 30d COMMON WIRE NAILS STAGGERED 30d COMMON WIRE NAILS FIRST 4 ROWS OF
<br />0/C w/ (2) 16d (D = 0.148", L = 3) OR EQUAL (D = 0.207' , L = 4 1/2') OR EQUAL (D = 0.207", L = 4 1/2") OR EQUAL ( )
<br />TOENAILS EA. END NOTES: TRUSSES FROM EA.
<br />@ 1) ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES 4) FOR 4-PLY, PROVIDE 1/4" DIA. x 5 1/2" LAG SCREWS OR EQUAL END TYP. TOP &
<br />BOTTOM ATTACHED
<br />MASONRY WALL OF THE COLUMN (SPACE AS SHOWN FOR 3-PLY) w/ (2)16d TOENAILS
<br />ARCHITECTURAL FINISH 2) ALL NAILS PENETRATE AT LEAST 3/4 OF THE THICKNESS 5) FOR 5-PLY, PROVIDE 1/4" DIA. x 7" LAG SCREWS OR EQUAL
<br />P A H N PLY
<br />2x4 BLOCKING 2x4 "T" BLOCKING
<br />@ 48" O.C. 16d NAIL
<br />"L" BRACE
<br />ATTACHED W/
<br />1Od NAILS @ 4"
<br />O.C. TYPICAL
<br />GABLE TRUSS WEB
<br />DOUBLE "L" BRACING DETAIL 5
<br />SCALE: N.T.S. S5
<br />2x4 "T" BLOCKING
<br />2x4 BLOCKING @
<br />48" O.C.
<br />"L" BRACE ATTACHED 16d NAIL
<br />W/ 10d NAILS @ 4" 0.C�
<br />TYPICAL
<br />GABLE TRUSS WEB —'
<br />SINGLE "L" BRACING DETAILS 6
<br />SCALE: N.T.S. 5
<br />DIAPHRAGM
<br />BLOCKING @
<br />48" 0/C GABLE TRUSS
<br />TRUSS VERTICAL
<br />2x4 LEDGER (MATCH BOTTOM CHORD DBL. TOP PLATE NAILS AATSIMPSONSP2 w/ (12)10d
<br />NAILS EACH STUD (2) 2"x8" "L" BRACE J
<br />SLOPE OF ADJACENT TRUSS) STUD WALL (SEE TYP. SEC.) FASTENED WITH (3)
<br />16d PER SIDE
<br />SECTION 3 SECTION 4 SCISSOR GABLE "T" BRACE
<br />SCALE: N.T.S. S5 SCALE: N.T.S. S5 REV. 06.08.22 AS PER HIB 91 SCALE: N.T.S. S5
<br />MAX. 9"
<br />UNSUPPORTED, 8d @ 6"O/C
<br />IF >9" SEE 10/S5 r WOOD TRUSSES
<br />"L" BRACE TO EXTEND
<br />AT LEAST 90% OF WEB
<br />LENGTH (SEE TABLE)
<br />-GABLE TRUSS
<br />-1/2" CDX PLYWOOD OR 7/16"
<br />OSB SHEATHING ATTACHED
<br />W/ 1Od NAILS @ 6" O.C. SIMPSON HGAMI OKTA w/ (4)
<br />E ES AND 12" O.C. FIELD 1/4"x1 1/2" SDS SCREWS TO
<br />JACK TRUSS BLOCKING & (4) 1/4"X2 3/4"
<br />SEE PLAN FOR TITEN TO CMU
<br />CONNECTION
<br />14�]
<br />OF THE LAST LAMINATION SPACE S SHOWN FOR 3- ) 2x4 "T" ON TOP OF PANEL I LL
<br />EXT. WALL CONN. 3) EACH 30d COMMON NAIL MAY BE REPLACED W/ (2) 16d 6) REFER TO NDS SECTION 15.3 FOR ADDITIONAL INFORMATION Odx3'BLOCKIN 4" FASTEN WITH [ 2x 12LOCKG TOENAILS/
<br />NON - LOAD BEARING LOCATION COMMON NAILS. (ONE INTO EACH OUTSIDE FACE OF
<br />D B.U.C., SAME NUMBER OF ROWS, SAME SPACING)
<br />SEE TYP. WALL SECTION FOR SCALE: 3/4"=1'-0" S5 TYPICAL NAILING SCHEDULES FOR BUILT-UP COLUMNS 8 SECTION g T
<br />ADDITIONAL INFORMATION. SCALE; N.T.S. S5 SCALE: N.T.S. S5
<br />11NIMUM 2x
<br />,ROSS BRACING
<br />SEE PLAN FOR
<br />OCATIONS)
<br />(2)16d PER
<br />JOINT
<br />f- CONTINUOUS BOTTOM CORD BRACING 2"x4" MI/N. SSEEEMM/S5
<br />CROSS BRACING DETAIL J
<br />SCALE: N.T.S.
<br />TOENAIL s
<br />(2)16d NA
<br />12"
<br />SH SCHEDULE
<br />,TTACHMENT
<br />? SYP BLK'G @ 16" O.C.
<br />I x 0.131"
<br />AILS EA. SIDE
<br />2x4 #2 SYP w/ 1 Od
<br />X0.131"@8"O.C.
<br />ALTERNATE NON -DROP
<br />GABLE END DETAIL 10
<br />SCALE: N.T.S. S5
<br />1 GABLE TRUSS
<br />S5
<br />"L" BRACE W/ 1 Od @ 4" O.C.
<br />12 (SEE SCHEDULE FOR SIZE
<br />AND LOCATION)
<br />6.9 MAX.
<br />S5
<br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION
<br />SCALE: N.T.S.
<br />PRE-ENGINEERED
<br />WOOD TRUSSES
<br />OVERLAP TRUSS BRACING
<br />AT LEAST TWO TRUSS SPACES
<br />`-MINIMUM (2)16d PER JOINT \-MINIMUM 2X4 TRUSS BRACING
<br />TRUSS BRACING OVERLAP DETAIL
<br />SCALE: N.T.S
<br />6" OVERLAP
<br />M
<br />S5
<br />"L" BRACE W/ 10d @ 4" O/C
<br />(SEE SCHEDULE FOR SIZE
<br />AND LOCATION)
<br />2 x 4 BLOCKING w/ (2)1 Od
<br />TOE NAILS AT EACH END @
<br />24" O/C (TYP)
<br />•
<br />a
<br />z
<br />UJI
<br />`,.BRACING w/ (3)10d x 3" AT
<br />EACH CONN. @ 24" O/C
<br />\-MOISTURE BARRIER
<br />-BOND BEAM
<br />MASONRY WALL
<br />ARCHITECTURAL FINISH
<br />EXT. WALL CONN. NON -LOAD
<br />BEARING LOCATIO(UNEVEN CLG.)
<br />SEE TYP. WALL SECTION FOR
<br />ADDITIONAL INFORMATION.
<br />SCALE: N.T.S.
<br />"L" BRACING REQUIREMENTS
<br />STUD NO (1) 2"x4" (U.N.O.) 2"X6" (U.N.O.)
<br />SPACING "L" BRACE "L" BRACE "L" BRACE
<br />24" 0'0" - T-0" T-O" - 6'-0" 6-0" & GREATER
<br />SCISSOR GABLE - (1) 2'W" #2 S.P.F. @ EACH VERTICAL AND
<br />(2) 2"x8" FULL HEIGHT @ DIAPHRAGM BLOCKING
<br />NOTE:
<br />1) "L" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES
<br />BRACE TO EXTEND FULL HEIGHT OF GABLE.
<br />2) "L" BRACE TO BE FASTENED TO GABLE STUD WITH 10dx3" NAILS @ 4" O/C.
<br />3) SEE 6/S5 FOR MORE INFO.
<br />SIMPSON HGA10KTw/ (4) 1/4"x1 1/2" SDS
<br />SCREWS TO TRUSS & (4) 1/4"x3" SDS SCREWS
<br />TO PLATES (TYP.)
<br />—wiv i. ocnnuva -
<br />GABLE END BRACING DETAIL SCALE:3/4"=1'-0"
<br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION
<br />SIMPSON SP2 w/ (12)
<br />10d NAILS AT EACH
<br />STUD
<br />HIP FRAMING REFERENCE PLAN
<br />20'-0" MAX 20'-0" MAX
<br />"X" BRACE SEE DET. J/S5 -, CONTINUOUS BOTTO CHORD BRACING 2X4 MIN.
<br />Lmq
<br />Ll MM
<br />cc
<br />MM
<br />NOTE: /-TOP CHORD 2X4 #2 SYP BRACING
<br />1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING @ 16" O.C. MAX. FOR FIRST (4)
<br />CUT SHEETS FOR ADDITIONAL PERMANENT BRACING BAYS
<br />THAT MY BE REQUIRED ZBOTTOM CHORD GABLE END BRACING
<br />2) '7 BRACING MAY BE USED IN PLACE OF PERMANENT @ 4'-0" O.C. MAX. FOR FIRST (4) BAYS
<br />BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB.
<br />REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN
<br />AS PER BCSI
<br />SCISSOR TRUSS
<br />SCISSOR TRUSS
<br />W/ DROP CEILING BRACING DETAIL
<br />SCALE: N.T.S.
<br />2X4 BRACING @ 48" O.C. CONTINUOUS TO
<br />FIXED LOCATION ATTACHED W/ (2)10d AT
<br />EA. TRUSS (NOTE: BRACING MAY BE
<br />PLACED ON EITHER TOP OR BOTTOM OF
<br />THE BOTTOM CORD)
<br />COSMETIC DROP CEILING FRAMING
<br />MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS
<br />SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION
<br />WOOD FRAMED GABLE END BRACING DETAIL
<br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S.
<br />FOR WIND SPEED SPECIFICATION
<br />e•�
<br />c1%j
<br />cl�4
<br />c�
<br />CD
<br />c
<br />L.0
<br />as LU
<br />> W
<br />i L
<br />U Q. Lam- O
<br />c �ae�N
<br />•sz N Y
<br />32 W
<br />� = _= C"
<br />�E=
<br />�+ via
<br />� � ro
<br />3
<br />� .!!! �
<br />CU
<br />a ,
<br />Ni7..-in
<br />C
<br />It
<br />_^� N SE
<br />w Ji
<br />.. G�
<br />J�' •... "� E a Q � �\`N
<br />�d6lt€till"
<br />To the best of the Engineers knowledge, information and belief,
<br />the structural plans and specifications contained within these
<br />drawings comply with the 2020 Florida Building Code -
<br />Residential 7th Edition. Engineers signature and seal is only for
<br />the structural engineering portions of the drawing pages bearing
<br />Engineers signature and seal.
<br />W
<br />:) h a E
<br />IMAM
<br />4MEE
<br />O N
<br />b' G
<br />at � N
<br />J
<br />�j 6J "r
<br />�i C 525 LL W
<br />.� °
<br />= -o a Y
<br />Z ��
<br />Y�o`_ t
<br />�. IL w _ N $
<br />W U5 Cj m w
<br />y co M Z ¢ J
<br />a N O U v
<br />U w
<br />❑ El
<br />V M M
<br />� N M
<br />o
<br />zco
<br />�QQ
<br />d v
<br />o- n
<br />U)
<br />N z
<br />Q) o
<br />W
<br />U � a
<br />OW c
<br />Ln �y N
<br />M U r6
<br />LU
<br />Ij M
<br />, = L z
<br />U o •
<br />Q N `=
<br />W
<br />Q Z
<br />M p 5> C
<br />J �
<br />ce
<br />LL zo >m
<br />a aN
<br />CL
<br />o oLL z©
<br />E 8 u oa
<br />(0 CIO
<br />�to Do
<br />a 0. 0a p�
<br />Q
<br />h wa ww
<br />r
<br />O
<br />a GU 0,
<br />z 6 <w
<br />z
<br />Z
<br />W w a
<br />�� ww
<br />oz r2�
<br />Mja
<br />o M11
<br />c 0
<br />0
<br />> (O
<br />LO
<br />^. '' hh
<br />m
<br />Q u!
<br />N N
<br />OCo
<br />ca
<br />Y — T
<br />m U) m ^
<br />L N
<br />}I C
<br />T Q '�O N �
<br /><C I )
<br />-� N Ln
<br />C3� N r
<br />1_ L0 T
<br />T
<br />E E M Z
<br />CU � N
<br />z E 0
<br />r_
<br />a U Q p
<br />JOB NO: 23-00522
<br />SCALE : AS NOTED
<br />SHEET NO.
<br />S5
<br />FT I_- fl I tq I I III I
<br />I �T il'l ii 7i� J. iT97r 3 - I
<br />OF THE LAST LAMINATION SPACE S SHOWN FOR 3- ) 2x4 "T" ON TOP OF PANEL I LL
<br />EXT. WALL CONN. 3) EACH 30d COMMON NAIL MAY BE REPLACED W/ (2) 16d 6) REFER TO NDS SECTION 15.3 FOR ADDITIONAL INFORMATION Odx3'BLOCKIN 4" FASTEN WITH [ 2x 12LOCKG TOENAILS/
<br />NON - LOAD BEARING LOCATION COMMON NAILS. (ONE INTO EACH OUTSIDE FACE OF
<br />D B.U.C., SAME NUMBER OF ROWS, SAME SPACING)
<br />SEE TYP. WALL SECTION FOR SCALE: 3/4"=1'-0" S5 TYPICAL NAILING SCHEDULES FOR BUILT-UP COLUMNS 8 SECTION g T
<br />ADDITIONAL INFORMATION. SCALE; N.T.S. S5 SCALE: N.T.S. S5
<br />11NIMUM 2x
<br />,ROSS BRACING
<br />SEE PLAN FOR
<br />OCATIONS)
<br />(2)16d PER
<br />JOINT
<br />f- CONTINUOUS BOTTOM CORD BRACING 2"x4" MI/N. SSEEEMM/S5
<br />CROSS BRACING DETAIL J
<br />SCALE: N.T.S.
<br />TOENAIL s
<br />(2)16d NA
<br />12"
<br />SH SCHEDULE
<br />,TTACHMENT
<br />? SYP BLK'G @ 16" O.C.
<br />I x 0.131"
<br />AILS EA. SIDE
<br />2x4 #2 SYP w/ 1 Od
<br />X0.131"@8"O.C.
<br />ALTERNATE NON -DROP
<br />GABLE END DETAIL 10
<br />SCALE: N.T.S. S5
<br />1 GABLE TRUSS
<br />S5
<br />"L" BRACE W/ 1 Od @ 4" O.C.
<br />12 (SEE SCHEDULE FOR SIZE
<br />AND LOCATION)
<br />6.9 MAX.
<br />S5
<br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION
<br />SCALE: N.T.S.
<br />PRE-ENGINEERED
<br />WOOD TRUSSES
<br />OVERLAP TRUSS BRACING
<br />AT LEAST TWO TRUSS SPACES
<br />`-MINIMUM (2)16d PER JOINT \-MINIMUM 2X4 TRUSS BRACING
<br />TRUSS BRACING OVERLAP DETAIL
<br />SCALE: N.T.S
<br />6" OVERLAP
<br />M
<br />S5
<br />"L" BRACE W/ 10d @ 4" O/C
<br />(SEE SCHEDULE FOR SIZE
<br />AND LOCATION)
<br />2 x 4 BLOCKING w/ (2)1 Od
<br />TOE NAILS AT EACH END @
<br />24" O/C (TYP)
<br />•
<br />a
<br />z
<br />UJI
<br />`,.BRACING w/ (3)10d x 3" AT
<br />EACH CONN. @ 24" O/C
<br />\-MOISTURE BARRIER
<br />-BOND BEAM
<br />MASONRY WALL
<br />ARCHITECTURAL FINISH
<br />EXT. WALL CONN. NON -LOAD
<br />BEARING LOCATIO(UNEVEN CLG.)
<br />SEE TYP. WALL SECTION FOR
<br />ADDITIONAL INFORMATION.
<br />SCALE: N.T.S.
<br />"L" BRACING REQUIREMENTS
<br />STUD NO (1) 2"x4" (U.N.O.) 2"X6" (U.N.O.)
<br />SPACING "L" BRACE "L" BRACE "L" BRACE
<br />24" 0'0" - T-0" T-O" - 6'-0" 6-0" & GREATER
<br />SCISSOR GABLE - (1) 2'W" #2 S.P.F. @ EACH VERTICAL AND
<br />(2) 2"x8" FULL HEIGHT @ DIAPHRAGM BLOCKING
<br />NOTE:
<br />1) "L" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES
<br />BRACE TO EXTEND FULL HEIGHT OF GABLE.
<br />2) "L" BRACE TO BE FASTENED TO GABLE STUD WITH 10dx3" NAILS @ 4" O/C.
<br />3) SEE 6/S5 FOR MORE INFO.
<br />SIMPSON HGA10KTw/ (4) 1/4"x1 1/2" SDS
<br />SCREWS TO TRUSS & (4) 1/4"x3" SDS SCREWS
<br />TO PLATES (TYP.)
<br />—wiv i. ocnnuva -
<br />GABLE END BRACING DETAIL SCALE:3/4"=1'-0"
<br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION
<br />SIMPSON SP2 w/ (12)
<br />10d NAILS AT EACH
<br />STUD
<br />HIP FRAMING REFERENCE PLAN
<br />20'-0" MAX 20'-0" MAX
<br />"X" BRACE SEE DET. J/S5 -, CONTINUOUS BOTTO CHORD BRACING 2X4 MIN.
<br />Lmq
<br />Ll MM
<br />cc
<br />MM
<br />NOTE: /-TOP CHORD 2X4 #2 SYP BRACING
<br />1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING @ 16" O.C. MAX. FOR FIRST (4)
<br />CUT SHEETS FOR ADDITIONAL PERMANENT BRACING BAYS
<br />THAT MY BE REQUIRED ZBOTTOM CHORD GABLE END BRACING
<br />2) '7 BRACING MAY BE USED IN PLACE OF PERMANENT @ 4'-0" O.C. MAX. FOR FIRST (4) BAYS
<br />BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB.
<br />REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN
<br />AS PER BCSI
<br />SCISSOR TRUSS
<br />SCISSOR TRUSS
<br />W/ DROP CEILING BRACING DETAIL
<br />SCALE: N.T.S.
<br />2X4 BRACING @ 48" O.C. CONTINUOUS TO
<br />FIXED LOCATION ATTACHED W/ (2)10d AT
<br />EA. TRUSS (NOTE: BRACING MAY BE
<br />PLACED ON EITHER TOP OR BOTTOM OF
<br />THE BOTTOM CORD)
<br />COSMETIC DROP CEILING FRAMING
<br />MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS
<br />SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION
<br />WOOD FRAMED GABLE END BRACING DETAIL
<br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S.
<br />FOR WIND SPEED SPECIFICATION
<br />e•�
<br />c1%j
<br />cl�4
<br />c�
<br />CD
<br />c
<br />L.0
<br />as LU
<br />> W
<br />i L
<br />U Q. Lam- O
<br />c �ae�N
<br />•sz N Y
<br />32 W
<br />� = _= C"
<br />�E=
<br />�+ via
<br />� � ro
<br />3
<br />� .!!! �
<br />CU
<br />a ,
<br />Ni7..-in
<br />C
<br />It
<br />_^� N SE
<br />w Ji
<br />.. G�
<br />J�' •... "� E a Q � �\`N
<br />�d6lt€till"
<br />To the best of the Engineers knowledge, information and belief,
<br />the structural plans and specifications contained within these
<br />drawings comply with the 2020 Florida Building Code -
<br />Residential 7th Edition. Engineers signature and seal is only for
<br />the structural engineering portions of the drawing pages bearing
<br />Engineers signature and seal.
<br />W
<br />:) h a E
<br />IMAM
<br />4MEE
<br />O N
<br />b' G
<br />at � N
<br />J
<br />�j 6J "r
<br />�i C 525 LL W
<br />.� °
<br />= -o a Y
<br />Z ��
<br />Y�o`_ t
<br />�. IL w _ N $
<br />W U5 Cj m w
<br />y co M Z ¢ J
<br />a N O U v
<br />U w
<br />❑ El
<br />V M M
<br />� N M
<br />o
<br />zco
<br />�QQ
<br />d v
<br />o- n
<br />U)
<br />N z
<br />Q) o
<br />W
<br />U � a
<br />OW c
<br />Ln �y N
<br />M U r6
<br />LU
<br />Ij M
<br />, = L z
<br />U o •
<br />Q N `=
<br />W
<br />Q Z
<br />M p 5> C
<br />J �
<br />ce
<br />LL zo >m
<br />a aN
<br />CL
<br />o oLL z©
<br />E 8 u oa
<br />(0 CIO
<br />�to Do
<br />a 0. 0a p�
<br />Q
<br />h wa ww
<br />r
<br />O
<br />a GU 0,
<br />z 6 <w
<br />z
<br />Z
<br />W w a
<br />�� ww
<br />oz r2�
<br />Mja
<br />o M11
<br />c 0
<br />0
<br />> (O
<br />LO
<br />^. '' hh
<br />m
<br />Q u!
<br />N N
<br />OCo
<br />ca
<br />Y — T
<br />m U) m ^
<br />L N
<br />}I C
<br />T Q '�O N �
<br /><C I )
<br />-� N Ln
<br />C3� N r
<br />1_ L0 T
<br />T
<br />E E M Z
<br />CU � N
<br />z E 0
<br />r_
<br />a U Q p
<br />JOB NO: 23-00522
<br />SCALE : AS NOTED
<br />SHEET NO.
<br />S5
<br />FT I_- fl I tq I I III I
<br />I �T il'l ii 7i� J. iT97r 3 - I
<br />11NIMUM 2x
<br />,ROSS BRACING
<br />SEE PLAN FOR
<br />OCATIONS)
<br />(2)16d PER
<br />JOINT
<br />f- CONTINUOUS BOTTOM CORD BRACING 2"x4" MI/N. SSEEEMM/S5
<br />CROSS BRACING DETAIL J
<br />SCALE: N.T.S.
<br />TOENAIL s
<br />(2)16d NA
<br />12"
<br />SH SCHEDULE
<br />,TTACHMENT
<br />? SYP BLK'G @ 16" O.C.
<br />I x 0.131"
<br />AILS EA. SIDE
<br />2x4 #2 SYP w/ 1 Od
<br />X0.131"@8"O.C.
<br />ALTERNATE NON -DROP
<br />GABLE END DETAIL 10
<br />SCALE: N.T.S. S5
<br />1 GABLE TRUSS
<br />S5
<br />"L" BRACE W/ 1 Od @ 4" O.C.
<br />12 (SEE SCHEDULE FOR SIZE
<br />AND LOCATION)
<br />6.9 MAX.
<br />S5
<br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION
<br />SCALE: N.T.S.
<br />PRE-ENGINEERED
<br />WOOD TRUSSES
<br />OVERLAP TRUSS BRACING
<br />AT LEAST TWO TRUSS SPACES
<br />`-MINIMUM (2)16d PER JOINT \-MINIMUM 2X4 TRUSS BRACING
<br />TRUSS BRACING OVERLAP DETAIL
<br />SCALE: N.T.S
<br />6" OVERLAP
<br />M
<br />S5
<br />"L" BRACE W/ 10d @ 4" O/C
<br />(SEE SCHEDULE FOR SIZE
<br />AND LOCATION)
<br />2 x 4 BLOCKING w/ (2)1 Od
<br />TOE NAILS AT EACH END @
<br />24" O/C (TYP)
<br />•
<br />a
<br />z
<br />UJI
<br />`,.BRACING w/ (3)10d x 3" AT
<br />EACH CONN. @ 24" O/C
<br />\-MOISTURE BARRIER
<br />-BOND BEAM
<br />MASONRY WALL
<br />ARCHITECTURAL FINISH
<br />EXT. WALL CONN. NON -LOAD
<br />BEARING LOCATIO(UNEVEN CLG.)
<br />SEE TYP. WALL SECTION FOR
<br />ADDITIONAL INFORMATION.
<br />SCALE: N.T.S.
<br />"L" BRACING REQUIREMENTS
<br />STUD NO (1) 2"x4" (U.N.O.) 2"X6" (U.N.O.)
<br />SPACING "L" BRACE "L" BRACE "L" BRACE
<br />24" 0'0" - T-0" T-O" - 6'-0" 6-0" & GREATER
<br />SCISSOR GABLE - (1) 2'W" #2 S.P.F. @ EACH VERTICAL AND
<br />(2) 2"x8" FULL HEIGHT @ DIAPHRAGM BLOCKING
<br />NOTE:
<br />1) "L" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES
<br />BRACE TO EXTEND FULL HEIGHT OF GABLE.
<br />2) "L" BRACE TO BE FASTENED TO GABLE STUD WITH 10dx3" NAILS @ 4" O/C.
<br />3) SEE 6/S5 FOR MORE INFO.
<br />SIMPSON HGA10KTw/ (4) 1/4"x1 1/2" SDS
<br />SCREWS TO TRUSS & (4) 1/4"x3" SDS SCREWS
<br />TO PLATES (TYP.)
<br />—wiv i. ocnnuva -
<br />GABLE END BRACING DETAIL SCALE:3/4"=1'-0"
<br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION
<br />SIMPSON SP2 w/ (12)
<br />10d NAILS AT EACH
<br />STUD
<br />HIP FRAMING REFERENCE PLAN
<br />20'-0" MAX 20'-0" MAX
<br />"X" BRACE SEE DET. J/S5 -, CONTINUOUS BOTTO CHORD BRACING 2X4 MIN.
<br />Lmq
<br />Ll MM
<br />cc
<br />MM
<br />NOTE: /-TOP CHORD 2X4 #2 SYP BRACING
<br />1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING @ 16" O.C. MAX. FOR FIRST (4)
<br />CUT SHEETS FOR ADDITIONAL PERMANENT BRACING BAYS
<br />THAT MY BE REQUIRED ZBOTTOM CHORD GABLE END BRACING
<br />2) '7 BRACING MAY BE USED IN PLACE OF PERMANENT @ 4'-0" O.C. MAX. FOR FIRST (4) BAYS
<br />BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB.
<br />REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN
<br />AS PER BCSI
<br />SCISSOR TRUSS
<br />SCISSOR TRUSS
<br />W/ DROP CEILING BRACING DETAIL
<br />SCALE: N.T.S.
<br />2X4 BRACING @ 48" O.C. CONTINUOUS TO
<br />FIXED LOCATION ATTACHED W/ (2)10d AT
<br />EA. TRUSS (NOTE: BRACING MAY BE
<br />PLACED ON EITHER TOP OR BOTTOM OF
<br />THE BOTTOM CORD)
<br />COSMETIC DROP CEILING FRAMING
<br />MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS
<br />SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION
<br />WOOD FRAMED GABLE END BRACING DETAIL
<br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S.
<br />FOR WIND SPEED SPECIFICATION
<br />e•�
<br />c1%j
<br />cl�4
<br />c�
<br />CD
<br />c
<br />L.0
<br />as LU
<br />> W
<br />i L
<br />U Q. Lam- O
<br />c �ae�N
<br />•sz N Y
<br />32 W
<br />� = _= C"
<br />�E=
<br />�+ via
<br />� � ro
<br />3
<br />� .!!! �
<br />CU
<br />a ,
<br />Ni7..-in
<br />C
<br />It
<br />_^� N SE
<br />w Ji
<br />.. G�
<br />J�' •... "� E a Q � �\`N
<br />�d6lt€till"
<br />To the best of the Engineers knowledge, information and belief,
<br />the structural plans and specifications contained within these
<br />drawings comply with the 2020 Florida Building Code -
<br />Residential 7th Edition. Engineers signature and seal is only for
<br />the structural engineering portions of the drawing pages bearing
<br />Engineers signature and seal.
<br />W
<br />:) h a E
<br />IMAM
<br />4MEE
<br />O N
<br />b' G
<br />at � N
<br />J
<br />�j 6J "r
<br />�i C 525 LL W
<br />.� °
<br />= -o a Y
<br />Z ��
<br />Y�o`_ t
<br />�. IL w _ N $
<br />W U5 Cj m w
<br />y co M Z ¢ J
<br />a N O U v
<br />U w
<br />❑ El
<br />V M M
<br />� N M
<br />o
<br />zco
<br />�QQ
<br />d v
<br />o- n
<br />U)
<br />N z
<br />Q) o
<br />W
<br />U � a
<br />OW c
<br />Ln �y N
<br />M U r6
<br />LU
<br />Ij M
<br />, = L z
<br />U o •
<br />Q N `=
<br />W
<br />Q Z
<br />M p 5> C
<br />J �
<br />ce
<br />LL zo >m
<br />a aN
<br />CL
<br />o oLL z©
<br />E 8 u oa
<br />(0 CIO
<br />�to Do
<br />a 0. 0a p�
<br />Q
<br />h wa ww
<br />r
<br />O
<br />a GU 0,
<br />z 6 <w
<br />z
<br />Z
<br />W w a
<br />�� ww
<br />oz r2�
<br />Mja
<br />o M11
<br />c 0
<br />0
<br />> (O
<br />LO
<br />^. '' hh
<br />m
<br />Q u!
<br />N N
<br />OCo
<br />ca
<br />Y — T
<br />m U) m ^
<br />L N
<br />}I C
<br />T Q '�O N �
<br /><C I )
<br />-� N Ln
<br />C3� N r
<br />1_ L0 T
<br />T
<br />E E M Z
<br />CU � N
<br />z E 0
<br />r_
<br />a U Q p
<br />JOB NO: 23-00522
<br />SCALE : AS NOTED
<br />SHEET NO.
<br />S5
<br />FT I_- fl I tq I I III I
<br />I �T il'l ii 7i� J. iT97r 3 - I
<br />NOTE:
<br />1) "L" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES
<br />BRACE TO EXTEND FULL HEIGHT OF GABLE.
<br />2) "L" BRACE TO BE FASTENED TO GABLE STUD WITH 10dx3" NAILS @ 4" O/C.
<br />3) SEE 6/S5 FOR MORE INFO.
<br />SIMPSON HGA10KTw/ (4) 1/4"x1 1/2" SDS
<br />SCREWS TO TRUSS & (4) 1/4"x3" SDS SCREWS
<br />TO PLATES (TYP.)
<br />—wiv i. ocnnuva -
<br />GABLE END BRACING DETAIL SCALE:3/4"=1'-0"
<br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION
<br />SIMPSON SP2 w/ (12)
<br />10d NAILS AT EACH
<br />STUD
<br />HIP FRAMING REFERENCE PLAN
<br />20'-0" MAX 20'-0" MAX
<br />"X" BRACE SEE DET. J/S5 -, CONTINUOUS BOTTO CHORD BRACING 2X4 MIN.
<br />Lmq
<br />Ll MM
<br />cc
<br />MM
<br />NOTE: /-TOP CHORD 2X4 #2 SYP BRACING
<br />1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING @ 16" O.C. MAX. FOR FIRST (4)
<br />CUT SHEETS FOR ADDITIONAL PERMANENT BRACING BAYS
<br />THAT MY BE REQUIRED ZBOTTOM CHORD GABLE END BRACING
<br />2) '7 BRACING MAY BE USED IN PLACE OF PERMANENT @ 4'-0" O.C. MAX. FOR FIRST (4) BAYS
<br />BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB.
<br />REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN
<br />AS PER BCSI
<br />SCISSOR TRUSS
<br />SCISSOR TRUSS
<br />W/ DROP CEILING BRACING DETAIL
<br />SCALE: N.T.S.
<br />2X4 BRACING @ 48" O.C. CONTINUOUS TO
<br />FIXED LOCATION ATTACHED W/ (2)10d AT
<br />EA. TRUSS (NOTE: BRACING MAY BE
<br />PLACED ON EITHER TOP OR BOTTOM OF
<br />THE BOTTOM CORD)
<br />COSMETIC DROP CEILING FRAMING
<br />MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS
<br />SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION
<br />WOOD FRAMED GABLE END BRACING DETAIL
<br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S.
<br />FOR WIND SPEED SPECIFICATION
<br />e•�
<br />c1%j
<br />cl�4
<br />c�
<br />CD
<br />c
<br />L.0
<br />as LU
<br />> W
<br />i L
<br />U Q. Lam- O
<br />c �ae�N
<br />•sz N Y
<br />32 W
<br />� = _= C"
<br />�E=
<br />�+ via
<br />� � ro
<br />3
<br />� .!!! �
<br />CU
<br />a ,
<br />Ni7..-in
<br />C
<br />It
<br />_^� N SE
<br />w Ji
<br />.. G�
<br />J�' •... "� E a Q � �\`N
<br />�d6lt€till"
<br />To the best of the Engineers knowledge, information and belief,
<br />the structural plans and specifications contained within these
<br />drawings comply with the 2020 Florida Building Code -
<br />Residential 7th Edition. Engineers signature and seal is only for
<br />the structural engineering portions of the drawing pages bearing
<br />Engineers signature and seal.
<br />W
<br />:) h a E
<br />IMAM
<br />4MEE
<br />O N
<br />b' G
<br />at � N
<br />J
<br />�j 6J "r
<br />�i C 525 LL W
<br />.� °
<br />= -o a Y
<br />Z ��
<br />Y�o`_ t
<br />�. IL w _ N $
<br />W U5 Cj m w
<br />y co M Z ¢ J
<br />a N O U v
<br />U w
<br />❑ El
<br />V M M
<br />� N M
<br />o
<br />zco
<br />�QQ
<br />d v
<br />o- n
<br />U)
<br />N z
<br />Q) o
<br />W
<br />U � a
<br />OW c
<br />Ln �y N
<br />M U r6
<br />LU
<br />Ij M
<br />, = L z
<br />U o •
<br />Q N `=
<br />W
<br />Q Z
<br />M p 5> C
<br />J �
<br />ce
<br />LL zo >m
<br />a aN
<br />CL
<br />o oLL z©
<br />E 8 u oa
<br />(0 CIO
<br />�to Do
<br />a 0. 0a p�
<br />Q
<br />h wa ww
<br />r
<br />O
<br />a GU 0,
<br />z 6 <w
<br />z
<br />Z
<br />W w a
<br />�� ww
<br />oz r2�
<br />Mja
<br />o M11
<br />c 0
<br />0
<br />> (O
<br />LO
<br />^. '' hh
<br />m
<br />Q u!
<br />N N
<br />OCo
<br />ca
<br />Y — T
<br />m U) m ^
<br />L N
<br />}I C
<br />T Q '�O N �
<br /><C I )
<br />-� N Ln
<br />C3� N r
<br />1_ L0 T
<br />T
<br />E E M Z
<br />CU � N
<br />z E 0
<br />r_
<br />a U Q p
<br />JOB NO: 23-00522
<br />SCALE : AS NOTED
<br />SHEET NO.
<br />S5
<br />FT I_- fl I tq I I III I
<br />I �T il'l ii 7i� J. iT97r 3 - I
<br />NOTE: /-TOP CHORD 2X4 #2 SYP BRACING
<br />1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING @ 16" O.C. MAX. FOR FIRST (4)
<br />CUT SHEETS FOR ADDITIONAL PERMANENT BRACING BAYS
<br />THAT MY BE REQUIRED ZBOTTOM CHORD GABLE END BRACING
<br />2) '7 BRACING MAY BE USED IN PLACE OF PERMANENT @ 4'-0" O.C. MAX. FOR FIRST (4) BAYS
<br />BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB.
<br />REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN
<br />AS PER BCSI
<br />SCISSOR TRUSS
<br />SCISSOR TRUSS
<br />W/ DROP CEILING BRACING DETAIL
<br />SCALE: N.T.S.
<br />2X4 BRACING @ 48" O.C. CONTINUOUS TO
<br />FIXED LOCATION ATTACHED W/ (2)10d AT
<br />EA. TRUSS (NOTE: BRACING MAY BE
<br />PLACED ON EITHER TOP OR BOTTOM OF
<br />THE BOTTOM CORD)
<br />COSMETIC DROP CEILING FRAMING
<br />MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS
<br />SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION
<br />WOOD FRAMED GABLE END BRACING DETAIL
<br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S.
<br />FOR WIND SPEED SPECIFICATION
<br />e•�
<br />c1%j
<br />cl�4
<br />c�
<br />CD
<br />c
<br />L.0
<br />as LU
<br />> W
<br />i L
<br />U Q. Lam- O
<br />c �ae�N
<br />•sz N Y
<br />32 W
<br />� = _= C"
<br />�E=
<br />�+ via
<br />� � ro
<br />3
<br />� .!!! �
<br />CU
<br />a ,
<br />Ni7..-in
<br />C
<br />It
<br />_^� N SE
<br />w Ji
<br />.. G�
<br />J�' •... "� E a Q � �\`N
<br />�d6lt€till"
<br />To the best of the Engineers knowledge, information and belief,
<br />the structural plans and specifications contained within these
<br />drawings comply with the 2020 Florida Building Code -
<br />Residential 7th Edition. Engineers signature and seal is only for
<br />the structural engineering portions of the drawing pages bearing
<br />Engineers signature and seal.
<br />W
<br />:) h a E
<br />IMAM
<br />4MEE
<br />O N
<br />b' G
<br />at � N
<br />J
<br />�j 6J "r
<br />�i C 525 LL W
<br />.� °
<br />= -o a Y
<br />Z ��
<br />Y�o`_ t
<br />�. IL w _ N $
<br />W U5 Cj m w
<br />y co M Z ¢ J
<br />a N O U v
<br />U w
<br />❑ El
<br />V M M
<br />� N M
<br />o
<br />zco
<br />�QQ
<br />d v
<br />o- n
<br />U)
<br />N z
<br />Q) o
<br />W
<br />U � a
<br />OW c
<br />Ln �y N
<br />M U r6
<br />LU
<br />Ij M
<br />, = L z
<br />U o •
<br />Q N `=
<br />W
<br />Q Z
<br />M p 5> C
<br />J �
<br />ce
<br />LL zo >m
<br />a aN
<br />CL
<br />o oLL z©
<br />E 8 u oa
<br />(0 CIO
<br />�to Do
<br />a 0. 0a p�
<br />Q
<br />h wa ww
<br />r
<br />O
<br />a GU 0,
<br />z 6 <w
<br />z
<br />Z
<br />W w a
<br />�� ww
<br />oz r2�
<br />Mja
<br />o M11
<br />c 0
<br />0
<br />> (O
<br />LO
<br />^. '' hh
<br />m
<br />Q u!
<br />N N
<br />OCo
<br />ca
<br />Y — T
<br />m U) m ^
<br />L N
<br />}I C
<br />T Q '�O N �
<br /><C I )
<br />-� N Ln
<br />C3� N r
<br />1_ L0 T
<br />T
<br />E E M Z
<br />CU � N
<br />z E 0
<br />r_
<br />a U Q p
<br />JOB NO: 23-00522
<br />SCALE : AS NOTED
<br />SHEET NO.
<br />S5
<br />FT I_- fl I tq I I III I
<br />I �T il'l ii 7i� J. iT97r 3 - I
<br />AS PER BCSI
<br />SCISSOR TRUSS
<br />SCISSOR TRUSS
<br />W/ DROP CEILING BRACING DETAIL
<br />SCALE: N.T.S.
<br />2X4 BRACING @ 48" O.C. CONTINUOUS TO
<br />FIXED LOCATION ATTACHED W/ (2)10d AT
<br />EA. TRUSS (NOTE: BRACING MAY BE
<br />PLACED ON EITHER TOP OR BOTTOM OF
<br />THE BOTTOM CORD)
<br />COSMETIC DROP CEILING FRAMING
<br />MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS
<br />SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION
<br />WOOD FRAMED GABLE END BRACING DETAIL
<br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S.
<br />FOR WIND SPEED SPECIFICATION
<br />e•�
<br />c1%j
<br />cl�4
<br />c�
<br />CD
<br />c
<br />L.0
<br />as LU
<br />> W
<br />i L
<br />U Q. Lam- O
<br />c �ae�N
<br />•sz N Y
<br />32 W
<br />� = _= C"
<br />�E=
<br />�+ via
<br />� � ro
<br />3
<br />� .!!! �
<br />CU
<br />a ,
<br />Ni7..-in
<br />C
<br />It
<br />_^� N SE
<br />w Ji
<br />.. G�
<br />J�' •... "� E a Q � �\`N
<br />�d6lt€till"
<br />To the best of the Engineers knowledge, information and belief,
<br />the structural plans and specifications contained within these
<br />drawings comply with the 2020 Florida Building Code -
<br />Residential 7th Edition. Engineers signature and seal is only for
<br />the structural engineering portions of the drawing pages bearing
<br />Engineers signature and seal.
<br />W
<br />:) h a E
<br />IMAM
<br />4MEE
<br />O N
<br />b' G
<br />at � N
<br />J
<br />�j 6J "r
<br />�i C 525 LL W
<br />.� °
<br />= -o a Y
<br />Z ��
<br />Y�o`_ t
<br />�. IL w _ N $
<br />W U5 Cj m w
<br />y co M Z ¢ J
<br />a N O U v
<br />U w
<br />❑ El
<br />V M M
<br />� N M
<br />o
<br />zco
<br />�QQ
<br />d v
<br />o- n
<br />U)
<br />N z
<br />Q) o
<br />W
<br />U � a
<br />OW c
<br />Ln �y N
<br />M U r6
<br />LU
<br />Ij M
<br />, = L z
<br />U o •
<br />Q N `=
<br />W
<br />Q Z
<br />M p 5> C
<br />J �
<br />ce
<br />LL zo >m
<br />a aN
<br />CL
<br />o oLL z©
<br />E 8 u oa
<br />(0 CIO
<br />�to Do
<br />a 0. 0a p�
<br />Q
<br />h wa ww
<br />r
<br />O
<br />a GU 0,
<br />z 6 <w
<br />z
<br />Z
<br />W w a
<br />�� ww
<br />oz r2�
<br />Mja
<br />o M11
<br />c 0
<br />0
<br />> (O
<br />LO
<br />^. '' hh
<br />m
<br />Q u!
<br />N N
<br />OCo
<br />ca
<br />Y — T
<br />m U) m ^
<br />L N
<br />}I C
<br />T Q '�O N �
<br /><C I )
<br />-� N Ln
<br />C3� N r
<br />1_ L0 T
<br />T
<br />E E M Z
<br />CU � N
<br />z E 0
<br />r_
<br />a U Q p
<br />JOB NO: 23-00522
<br />SCALE : AS NOTED
<br />SHEET NO.
<br />S5
<br />FT I_- fl I tq I I III I
<br />I �T il'l ii 7i� J. iT97r 3 - I
<br />FT I_- fl I tq I I III I
<br />I �T il'l ii 7i� J. iT97r 3 - I